Views
8 months ago

-TechManual_SRK05,09,12CR-S,CRR-S,CRP-S

Item Model '15 •

Item Model '15 • SRK-T-171 SRK12CR-S3 Indoor unit SRK12CR-S3 Outdoor unit SRC12CR-S3 5.1 Fine snow Stucco white (8.0Y 9.3/0.1) near equivalent (4.2Y 7.5/1.1) near equivalent Compressor overheat protection, Frost protection, Serial signal error protection, Fan motor error protection, Liquid line : 0.57 — Gas line : 0.55 Necessary (Both sides), independent Max. 15 Max.5 (Outdoor unit is higher) Max.5 (Outdoor unit is lower) 1.5mm 2 x 3 cores (Including earth cable) Terminal block (Screw fixing type) Mounting kit The pipe length is 5m. Standards - 22 - Cooling capacity (1) W 3450 Power source 1 Phase, 220-240V, 50Hz Operation data Power consumption Running current Cooling kW 1.12 Cooling A Inrush current 7.5 COP Cooling 3.08 Noise level Cooling Sound level dB(A) Hi : 43 Me : 39 Lo : 36 50 Power level dB 57 61 Exterior dimensions (Height x Width x Depth) mm 268 x 790 x 222 595 x 780 (+62) x 290 Exterior appearance (Munsell color) Net weight kg 7 31 Refrigerant equipment Air handling equipment Compressor type & Q'ty — GKS139PAA ( Rotary type ) x 1 Motor (Starting method) kW — PSC Refrigerant oil l 0.30 ,POE(RB68A) or PVE(FVC68D) Refrigerant (4) kg R410A 0.78 ( Pre-charged up to the piping length of 5m ) Heat exchanger Louver fins & inner grooved tubing Louver fins & inner grooved tubing Refrigerant control Capillary tubes Device control Microcomputer control Fan type & Q'ty Tangential fan x 1 Propeller fan x 1 Motor W 17 25 Air flow Cooling m 3 /min 15 38 Fresh air intake Not possible — Air filter, Quality / Quantity Polypropylene net (washable) x 2 — Shock & vibration absorber — Cushion rubber (for compressor) Operation control Safety devices Installation data Operation switch Wireless remote control — Room temperature control Microcomputer thermostat — Operation display RUN : Green, TIMER : Yellow Refrigerant piping size (O.D) mm Liquid line: φ6.35 (1/4") Gas line: φ12.7 (1/2") Connecting method Flare connecting Attached length of piping Insulation for piping Refrigerant line (one way) length Vertical height difference between outdoor unit and indoor unit m m Drain hose Connectable (VP 16) — Power cable 2m (3 Cores wih Earth) Recommended breaker size A 20 Size x Core number Connection wiring Connecting method Accessories (included) Option parts — Note (1) The data are measured at the following conditions. Operation Item Indoor air temperature Outdoor air temperature DB WB DB WB Cooling 27˚C 19˚C 35˚C 24˚C ISO-T1, JIS C 9612 (2) This air-conditioner is manufactured and tested in conformity with the ISO. (3) The operation data are applied to the 230V districts respectively. (4) The refrigerant quantity to be charged includes the refrigerant in 5m connecting piping. (Purging is not required even for the short piping.) If the piping length is 5m to 15m, additional refrigerant is 10g per each 1m longer than 5m.

Item Model '15 • SRK-T-171 SRK12CR-S4 Indoor unit SRK12CR-S4 Outdoor unit SRC12CR-S4 5.1 Fine snow Stucco white (8.0Y 9.3/0.1) near equivalent (4.2Y 7.5/1.1) near equivalent Compressor overheat protection, Frost protection, Serial signal error protection, Fan motor error protection, Liquid line : 0.57 — Gas line : 0.55 Necessary (Both sides), independent Max. 15 Max.5 (Outdoor unit is higher) Max.5 (Outdoor unit is lower) 1.5mm 2 x 3 cores (Including earth cable) Terminal block (Screw fixing type) Mounting kit The pipe length is 5m. Standards - 23 - Cooling capacity (1) W 3450 Power source 1 Phase, 220-240V, 50Hz Operation data Power consumption Running current Cooling kW 1.12 Cooling A Inrush current 7.5 COP Cooling 3.08 Noise level Cooling Sound level dB(A) Hi : 43 Me : 39 Lo : 36 50 Power level dB 57 61 Exterior dimensions (Height x Width x Depth) mm 268 x 790 x 222 595 x 780 (+62) x 290 Exterior appearance (Munsell color) Net weight kg 7 31 Refrigerant equipment Air handling equipment Compressor type & Q'ty — GKS139PAA ( Rotary type ) x 1 Motor (Starting method) kW — PSC Refrigerant oil l 0.30 ,POE(RB68A) or PVE(FVC68D) Refrigerant (4) kg R410A 0.78 ( Pre-charged up to the piping length of 5m ) Heat exchanger Louver fins & inner grooved tubing Louver fins & inner grooved tubing Refrigerant control Capillary tubes Device control Microcomputer control Fan type & Q'ty Tangential fan x 1 Propeller fan x 1 Motor W 17 25 Air flow Cooling m 3 /min 15 38 Fresh air intake Not possible — Air filter, Quality / Quantity Polypropylene net (washable) x 2 — Shock & vibration absorber — Cushion rubber (for compressor) Operation control Safety devices Installation data Operation switch Wireless remote control — Room temperature control Microcomputer thermostat — Operation display RUN : Green, TIMER : Yellow Refrigerant piping size (O.D) mm Liquid line: φ6.35 (1/4") Gas line: φ12.7 (1/2") Connecting method Flare connecting Attached length of piping Insulation for piping Refrigerant line (one way) length Vertical height difference between outdoor unit and indoor unit m m Drain hose Connectable (VP 16) — Power cable 2m (3 Cores wih Earth) Recommended breaker size A 20 Size x Core number Connection wiring Connecting method Accessories (included) Option parts — Note (1) The data are measured at the following conditions. Operation Item Indoor air temperature Outdoor air temperature DB WB DB WB Cooling 27˚C 19˚C 35˚C 24˚C ISO-T1, JIS C 9612 (2) This air-conditioner is manufactured and tested in conformity with the ISO. (3) The operation data are applied to the 230V districts respectively. (4) The refrigerant quantity to be charged includes the refrigerant in 5m connecting piping. (Purging is not required even for the short piping.) If the piping length is 5m to 15m, additional refrigerant is 10g per each 1m longer than 5m.

Vrviii-s
1. Multiple piping type - The Energy Conscious
1. Multiple piping type - The Energy Conscious
Multi V Water II - ASHRAE Qatar
Bedford Tel: 01234 272702 Birmingham Tel: 0121 313 6720 Bristol ...
2010 PRODUCT CATALOGUE
Eco Compact H1 Series - Ferret
Outdoor Unit
Set Free R410A
2010 ECO-i Tech Tips - Panasonic
Bedford Tel: 01234 272702 Birmingham Tel ... - 3D Air Sales Ltd.
2011 Price List - EUR - Mitsubishi Heavy Industries Ltd.
VRVIII-S - Brochure - Daikin AC
60% reduced - Szathmáry service kft
A2 35YHA1 - Hitachi Air Conditioning Products
General Product Catalog - Daikin AC
The Multi-talented VRV-S. - Pacific HVAC Air Conditioner
High Performance Air to Water Heat Pump - BVTPartneri.lv
AIR CONDITIONING
SAMSUNG Eco Heating System
Multi-Split System Tri-Fold Flyer - Daikin AC
Set Free
Building Life Begins With You - Sanyo
P-Series Full-line Catalog - Duncklee Cooling & Heating Inc.
HR-E586P (PDF 2.2Mbyte) - Hitachi Appliances, Inc.
FJM Multi Split System - Samsung
ENGiNEERiNG AND SPECiFiCATioNS GuiDE - Split Air Conditioner
Hitachi Set Free sistems (PDF) - Rolvika
Micro - Mitsubishi Heavy Industries
HR-E607P (PDF 6.09Mbyte) - Hitachi Appliances, Inc.