Views
6 months ago

-TechManual_SRK05,09,12CR-S,CRR-S,CRP-S

5. PIPING SYSTEM Room

5. PIPING SYSTEM Room temp. sensor Heat exchanger Room temp. sensor Heat exchanger '15 • SRK-T-171 Models SRK05CR-S, S3, S6 SRK05CRP-S, S3 SRK09CR-S, S3, S4, S5 SRK09CRP-S, S3, S5 SRC09CRR-S, S3, S4, S5, S6 Indoor unit Outdoor unit Flare connecting Service valve (Gas) Piping Check joint (Gas) ø9.52 Accumulator Heat exchanger sensor Compressor Piping (Liquid) ø6.35 Service valve (Liquid) Capillary tube Flare connecting Models SRK12CR-S, S3, S4, S5, S6 Indoor unit Outdoor unit Flare connecting Service valve (Gas) Piping Check joint (Gas) ø12.7 Accumulator Heat exchanger sensor Compressor Piping (Liquid) ø6.35 Service valve (Liquid) Capillary tube Capillary tube Flare connecting - 40 - Heat exchanger Heat exchanger

6. RANGE OF USAGE & LIMITATIONS '15 • SRK-T-171 Models Item All model Indoor return air temperature (Upper, lower limits) Outdoor air temperature Refer to the selection chart (Upper, lower limits) Refrigerant line (one way) length Max. 15m Vertical height difference between Max. 5m (Outdoor unit is higher) outdoor unit and indoor unit Max. 5m (Outdoor unit is lower) Power source voltage Rating 10% Voltage at starting Min. 85% of rating Frequency of ON−OFF cycle Max. 10 times/h ON and OFF interval Min. 3 minutes Net capacity = Capacity shown on specification Correction factors as follows. (1) Coefficient of cooling capacity in relation to temperatures 1.3 1.2 Cooling 1.1 1.0 0.9 0.8 0.7 0.6 Applicable range 43 40 35 30 25 20 24 15 14 16 18 20 22 Indoor air W.B. temperature °C W.B. ISO-T1 Standard Condition Coefficient of cooling capacity in relation to temperature Cooling operation Outdoor air D.B. temperature °C D.B.

2011 Price List - EUR - Mitsubishi Heavy Industries Ltd.
Bedford Tel: 01234 272702 Birmingham Tel ... - 3D Air Sales Ltd.
60% reduced - Szathmáry service kft
HR-E586P (PDF 2.2Mbyte) - Hitachi Appliances, Inc.
P-Series Full-line Catalog - Duncklee Cooling & Heating Inc.
ENGiNEERiNG AND SPECiFiCATiONS GuiDE - Coastal Winair Co.
High Performance Air to Water Heat Pump - BVT Partners OÜ
Gas Engine Powered VRF Systems - Mitsubishi Heavy Industries Ltd.
1. Multiple piping type - The Energy Conscious
1. Multiple piping type - The Energy Conscious
City Multi Catalogue-VRF1 - Calcuttayellowpages.com
Premium efficiency splits - Tangra
VRF Air Conditioning System 8HP / 10HP 22.4kW / 28kW ... - Fujiaire
DA 2000 high-pressure cooling Poultry - Skov A/S
VRV-WIII - Brochure - PCVWUSE11-03C - Daikin AC