Views
1 week ago

-TechManual_SRK05,09,12CR-S,CRR-S,CRP-S

Standard accessories

Standard accessories (Installation kit) Accessories for indoor unit Installation board (Attached to the rear of the indoor unit) Selection of installation location Where there is no obstructions to the air flow and where the cooled air can be evenly distributed. A solid place where the unit or the wall will not vibrate. A place where there will be enough space for servicing. (Where space mentioned right can be secured) Where wiring and the piping work will be easy to conduct. The place where receiving part is not exposed to the direct rays of the sun or the strong rays of the street lighting. A place where it can be easily drained. A place separated at least 1m away from the television or the radio. (To prevent interfence to images and sounds.) A place that home appliance and household goods, etc. aren’t below unit. A place where good air circulation can be obtained and where rain, snow or sunshine will not directly strike the unit. A place where discharged hot air or unit’s operating sound will not be a nuisance to the neighborhood. A place where servicing space can be secured. A place where vibration will not be enlarged. *Avoid installing in the following places. place near the bedroom and the like, so that the operation noise will cause no trouble. A place where there is possibility of flammable gas leakage. exposed to strong wind. a salt-laden atmosphere or a place where the generation of oil mist, vapor or fume is expected. Blowing out port and suction port on the back side of the unit can be installed at a distance of 10cm from walls. case the barrier is 1.2m or above in height, or is overhead, the ( ) sufficient space between the unit and wall shall be secured. When the unit is installed, the space of the following dimension and above shall be secured. Q'ty Wireless remote control 1 Remote control holder 1 Tapping screws (for installation board 4dia. by 25mm) Wood screw (for remote contorol switch holder 3.5dia. by 16mm) Battery [R03 (AAA, Micro) 1.5V] 2 Option parts 1 5 2 Q'ty Sealing plate 1 Sleeve 1 Inclination plate 1 Putty 1 Drain hose (extention hose) 1 Piping cover (for insulation of connection piping) INDOOR UNIT OUTDOOR UNIT 1 '15 • SRK-T-171 Necessary tools for the installation work (1.4 ~ 8.2kgf · m)) Vacuum pump adapter (Anti-reverse ( Designed for R410A ) type) for R410A ) for R410A ) for R410A ) Gas leak detector ( Designed for R410A ) Gauge for projection adjustment (Used when is made by using conventional tool) 10 cm Right side Left side 10 cm 5 cm Air intake 10 cm No obstacles (Service space for electrical parts) Air intake Air outlet Note (1) the wall is higher than 1.2 m or a ceiling is present, distances larger than indicated in the above table must be provided. – 28– - 48 - 1 Plus headed driver (Phillips screwdriver) 2 Knife 3 Saw 4 Tape measure 5 Hammer 6 Spanner wrench 7 Torque wrench 14.0 ~ 82.0N · m ( 8 Hole core drill (65mm in diameter) 9 Wrench key (Hexagon) [4m/m] 10 Vacuum pump 11 12 Gauge manifold ( Designed 13 Change hose ( Designed 14 Flaring tool set ( Designed 15 16 17 Pipe bender RMA012A080_091-093_EN.indb 28 05/11/2014 11:50:41

Limitations for one way piping length and vertical height difference One way piping length ( ) Vertical height difference (h) Installation of indoor unit Installation of installation board • Adjustment of the installation board in the horizontal direction is to be conducted with ve screws in a temporary tightened state. Standard hole Outdoor unit is lower Outdoor unit is higher 15 m 5 m 5 m Look for the inside wall structures (Intersediate support or pillar and raly install the unit after level surface has been checked.) 250 Mating mark for level surface • Adjust so that board will be level by turning the board with the standard hole as the center. Look for the inside wall structures (Intersediate support or pillar and raly install the unit after level surface has been checked.) 394 • Adjustment of the installation board in the horizontal direction is to be conducted with ve screws in a temporary tightened state. Standard hole Mating mark for level surface • Adjust so that board will be level by turning the board with the standard hole as the center. 190 40.1 '15 • SRK-T-171 INSTALLATION SPACE (INDOOR UNIT) (FRONT VIEW) Indoor unit Unit : mm Installation board Space for service Space for service 100 155.4 155.4 100 181.9 250 181.9 44 44 Drain hose 386.3 (Ø16) Piping for Gas 398.2 Piping for Liquid 455.9 Piping hole (Ø65) Piping hole (Ø65) * Leave extra space on the right side to enable removal of the lid screw. INSTALLATION SPACE (INDOOR UNIT) (FRONT VIEW) Unit : mm Space for Indoor unit Space for service service 50 Installation board 100 187.5 394 187.5 157 455 157 130.5 508 130.5 55 55 Piping for Gas 409 Piping for Liquid 449 Piping hole (Ø65) Drain hose 530 (Ø16) Piping hole (Ø65) – 29 – 47 40 56 69.9 56 * Leave extra space on the right side to enable removal of the lid screw. RMA012A080_091-093_EN.indb 29 05/11/2014 11:50:41 7.2 7.7 100 Space for service 47 15 Space for service* Space for service 100 Space for service* 15 7.6 247.5 6.9

1. Multiple piping type - The Energy Conscious
1. Multiple piping type - The Energy Conscious
VRVIII-S - Brochure - Daikin AC
A2 35YHA1 - Hitachi Air Conditioning Products
Bedford Tel: 01234 272702 Birmingham Tel ... - 3D Air Sales Ltd.
2011 Price List - EUR - Mitsubishi Heavy Industries Ltd.
60% reduced - Szathmáry service kft
Bedford Tel: 01234 272702 Birmingham Tel: 0121 313 6720 Bristol ...
General Product Catalog - Daikin AC
2010 PRODUCT CATALOGUE
Eco Compact H1 Series - Ferret
The Multi-talented VRV-S. - Pacific HVAC Air Conditioner
Multi-Split System Tri-Fold Flyer - Daikin AC
High Performance Air to Water Heat Pump - BVTPartneri.lv
PDF 3.4MB - Con Edison Commercial & Industrial Energy Efficiency ...
HR-E586P (PDF 2.2Mbyte) - Hitachi Appliances, Inc.
Chapter 2 Introduction of Pioneer products
Building Life Begins With You - Monroe Equipment, Inc.
HR-E607P (PDF 6.09Mbyte) - Hitachi Appliances, Inc.
Hitachi Set Free sistems (PDF) - Rolvika
Micro - Mitsubishi Heavy Industries