Views
9 months ago

CAPITOL TECHNICAL MANUAL

OPUS POLYMER ENCORE

OPUS POLYMER ENCORE INSIDE ENCORE OUTSIDE H Section Used between panels in U channel to block light gaps between panels. Not available Louvre Locks Louvre locks allow louvres to be secured in place at the fully closed and / or 40º position. More control in weather conditions or for the safety conscious. Not available Beading / Angle Polymer light block can be used all 4 x sides front & rear for fixing OPUS, or aluminium angle to dress left & right sides for ENCORE. 19mm 19mm • 25mm x 25mm • 25mm x 10mm • 50mm x 20mm • 25mm x 25mm • 25mm x 10mm • 50mm x 20mm Magnets & Striker Plates Bullet magnets are rebated into OPUS stiles and attached to a backplate for ENCORE. Round striker plates are standard or L shaped on request. For fixed panels, request ‘magnets, no hinges’. Flyscreening Nylon fly screen and spline is attached to the rear of panels, mounted on angle. Extra charges apply. Not available Tilt rod can be attached front or rear, depending on your preference. Mounting Tube 50mm x 50mm mounting tube can be used as an infill to accommodate sloping rooflines / ceilings or anywhere you require to install a fixing point. Not available 28

TRACK BIFOLD PANELS Track bifold panels are top hung and run on wheel carriers in top and bottom track, with bottom guides in bottom track. Bifolds are supplied with or without box out boards depending on your requirements. Note that floor track is a requirement and any request for panels without floor track will be rejected. All tracks are clear anodised and supplied with high quality hardware. ENCORE Outside hardware is stainless steel by default. OPUS floor track is recessed in bottom boards and supplied loose as M track with double sided tape for no bottom board layouts. Stiles can be rabbet (default) or astragal (D mould) for OPUS and astragal (D mould) for ENCORE, to minimise light gap between panels. Note if using track bifolds as a room divider, you will need to order extra fascia for the rear. An even number of panels must stack in one direction with the end panel returning to the track. For example, 4 x panels could have 2 stacking each way or all 4 to one side. 6 x panels would need 4 stacking one way and 2 the other, or all 6 stacking to one side. We recommend a maximum of 6 x panels stacking in one direction to ensure a smooth operation. Track bifold panels do not fold back against the wall but stack at 90° into the room. The wider the panel, the more depth into the room they require when stacked open. Hinges are pre-fitted to all panels and supplied as rabbet hinges for OPUS and non-mortise hinges for ENCORE. By default, hinges are attached so that panels stack in toward the operator and the layout code refers to the stacking direction. If panels are required to fold away from the user, please request ‘reverse hinged’ in order notes. TRACK BIFOLD – Example Layouts L-L-L-L R-R-R-R 4 x panels folding to left 4 x panels folding to right L-L-R-R L-L-L-L-R-R-R-R 2 x panels folding to left, 2 x panels folding to right 4 x panels folding to left, 4 x panels folding to right 29

Technical Manual
CAPITOL CORRIDOR
Capitol Capitol - Minnesota's Private Colleges
Technical Manual - GC America
Technical Manual. PDF - smartclad
Technical Manual - Tyrolia
TECHNICAL MANUAL - Tyrolia
Technical Manual - Rlsd
TECHNICAL MANUAL
A Technical Manual for Landowners, Loggers, and ... - Forestry
TECHNICAL MANUAL - Megasun Solar Systems
EXHIBITION TECHNICAL MANUAL - Kenes Group
KomGuide - Technical Manual - Komet Group
JellyFish® filter technical manual - Humes
Capitol Celebrates 80 Years! - Capitol College