Views
7 months ago

CAPITOL TECHNICAL MANUAL

32

TRACK BYPASS PANELS Track bypass panels are top hung and slide on wheel carriers in top and bottom track, with bottom guides in bottom track. Bypass panels are supplied with or without box out boards. Note that floor track is a requirement and any request for panels without floor track will be rejected. All tracks are clear anodised and supplied with high quality hardware. ENCORE Outside hardware is stainless steel by default. OPUS floor track is recessed in bottom boards and supplied loose as M track with double sided tape for no bottom board layouts. The number of tracks is dictated by the depth of the board system. For OPUS and ENCORE Inside, the maximum is two (double) tracks. ENCORE Outside can be used without a board system and the number of tracks is determined by your application. Single panels cannot exceed specifications. Panels may be co-joined using hinges to accommodate wide openings. Co-joined panels are supplied as single panels with the male and female hinge parts already attached to each panel, ready for the fitter to butt each together and drop in the hinge pin. Both panels slide together to operate as one oversized panel. Panels can slide past each other in the closed or open position. Bypass Open Bypass open panels pass each other with louvres in the opened or closed position, and a block of material is attached to the rear of the front panels, and the front of the rear panels to block out additional light. Box out boards are deeper to accommodate the extra depth required for panels to function this way. Bypass Close Bypass closed panels can only pass each other with the louvres in the closed position. Box out boards are smaller as less depth is required for panels to function this way, so the shutters do not. Most bypass, or sliding panels, will use a double (2) track system, however a triple track can be used in some situations, without a board system. Layout codes differ for bypass shutters as we reference the track location for each panel rather than stacking direction or hinge side. Layout is indicated by front track (F) or rear (R) and panels slide freely on each track. 33

CAPITOL CORRIDOR
Capitol Capitol - Minnesota's Private Colleges
Technical Manual - GC America
Technical Manual - Tyrolia
Technical Manual - Rlsd
TECHNICAL MANUAL - Tyrolia
Technical Manual. PDF - smartclad
EXHIBITION TECHNICAL MANUAL - Kenes Group
A Technical Manual for Landowners, Loggers, and ... - Forestry
KomGuide - Technical Manual - Komet Group
TECHNICAL MANUAL - Megasun Solar Systems
JellyFish® filter technical manual - Humes
Capitol Celebrates 80 Years! - Capitol College
Capitol 02 - Consideratii generale
Combitherm Gas Technical Service Manual - Parts Town