Views
1 week ago

ECOBuilder-Specifiers Journal spring2018

FEATURE ARTICLE: ICOM

FEATURE ARTICLE: ICOM ENERGY ASSOCIATION Better networking for carbon reduction In 2017 the Department for Business, Energy and Industrial Strategy (BEIS) noted: “Heat networks form an important part of our plan to reduce carbon and cut heating bills for customers (domestic and commercial). They are one of the most costeffective ways of reducing carbon emissions from heating, and their efficiency and carbonsaving potential increases as they grow and connect to each other.” In its Clean Growth Strategy, BEIS has also stated an intention to build and extend heat networks across the country. So, clearly, heat networks have a key role to play in reducing the UK’s carbon emissions. Indeed, the Committee on Climate Change estimates that heat networks will need to supply approximately 18% of the UK’s heat by 2050 if we are to meet our carbon reduction targets. The UK government is also making funding available to help local authorities through the Heat Networks Investment Project – to the tune of £320m – to explore the feasibility of district heating systems in their areas. Unfortunately, heat networks (aka district heating) have had something of a chequered past in the UK. However, when heat networks don’t perform as hoped, the cause is usually down to the failure to design the system correctly. 62 SPECIFIERS JOURNAL - SPRING 2018 End-to-end approach Achieving optimum performance for a heat network requires a whole system approach, from the efficiency of the central heatgenerating plant and associated thermal storage through to the heat interface units (HIUs) in the heated spaces. There are also calls to design systems for operation with lower flow and return water temperatures than are traditional in the UK. For example, the Chartered Institution of Building Services Engineers (CIBSE) AM12 ‘Combined Heat and Power for Buildings’ recommends operating temperatures for radiator circuits to be no more than 70°C flow and 40°C return for new district heating systems/heat networks. The recommended maximum return temperature from instantaneous domestic hot water heat exchangers is 25°C. Lower operating temperatures are also recommended in the Heat Networks Code of Practice, jointly developed by CIBSE and the Association for Decentralised Energy (ADE). System overview Most heat networks being installed in the UK use a central plant room serving multioccupancy buildings or small groups of buildings. Many of these are using combined heat and power (CHP) to generate heat and electricity – the latter either being used in the building, Heat networks have the potential to make a significant contribution to the UK’s carbon reduction strategy. *Ross Anderson of ICOM explains Ross Anderson, Director, ICOM sold back to the grid, or both. Very often, the CHP will be combined with other heat sources including gas, oil or biomass boilers, heat pumps and solar thermal. Where a mix of heat sources is in use the design should account for the differing performance characteristics of each type of plant and seek to optimise each. Care must also be taken to ensure that none of the plant is oversized – a common problem in the past – as this introduces inherent inefficiencies to the system. A typical example would be sizing the CHP to meet base heat loads throughout the year. Ideally, if the CHP is used to generate electrical power through the summer, then any surplus heat produced by the CHP could be stored in a thermal storage vessel to supply domestic hot water, or to drive an absorption chiller for comfort cooling.

FEATURE ARTICLE: ICOM ENERGY ASSOCIATION compared to accessing individual boilers in each space/apartment. In the winter, when the base load is higher, a biomass boiler might be used to back the CHP up, with responsive heat sources such as modulating gas boilers ‘kicking in’ to meet peak loads whilst maintaining constant flow temperatures. Where the energy centre is providing domestic hot water as well as space heating, there may also be benefits to including calorifiers or heat exchangers feeding into buffer vessels. Such an arrangement allows solar heating or heat pumps to be used to pre-heat the cold mains water, with one of the other heat sources bringing it up the required temperature. A key benefit of using central energy centres in this way is that new, low carbon heat sources can be introduced relatively easily in the future without disruption to the spaces being heated. It is likely that with the growth of renewable energy in the UK, particularly from wind (the UK now has the largest installed offshore wind capacity in the world), future energy centres will need to include ways to make use of surplus electricity, such as heat pumps. In some locations, energy centres may also be able to take advantage of nearby waste energy sources from industry or waste incineration. All of which means that energy centres will require a high level flexibility and this needs to be addressed in the initial design. Centralisation of heat sources also simplifies routine maintenance, HIUs and sub-stations Hot water from the central plant room, to be used for space heating and hot water, will usually be controlled and metered through an HIU in each space. HIUs can vary considerably in performance so its important to ensure the HIU design will maintain consistent temperatures and pressures throughout the building and can adjust to variable demand. Where several buildings are involved there may also be variation between the heating systems in each building, especially if they were constructed at different times. In such cases, there may also be a need for a sub-station (heat transfer station) in each building that’s connected to the network. These provide an interface between the heat network and the building’s heating system and can be adjusted to suit the requirements of each building. Summary Given all of the factors considered above it is clear that every aspect of heat networks, from central plant through to HIUs in each space, must be considered and optimised in the design. Provision should also be made for future technical developments by ensuring the central energy centre has the inherent flexibility to enable cost-effective upgrades in the future. SPECIFIERS JOURNAL - SPRING 2018 63

The Victorian Terrace, BRE Innovation Park - Ecobuild Product Search
Solar Panels - Ecobuild Product Search
Durability by Design Brochure - Ecobuild Product Search
Dulas Catalogue - Ecobuild Product Search
ENERGATE - Ecobuild
Systems & Solutions for a changing World! - Ecobuild
SPECIFIERS CLIENTS AND SUPPLIERS
Wood Fibreboard Product Applications - Ecobuild
the environmentally compatible building product - Ecobuild
TECU® Copper for Roof and Façade Cladding Product ... - Ecobuild
Low Thermal Conductivity Wall Ties - Ecobuild
Rationel Catalogue - Ecobuild Product Search
The KVH®-1plus® warranty system. - Ecobuild
Insulate Magazine Ecobuild 2018 Special Edition
Beaumont Window Information - Ecobuild Product Search
Product Brochure - Ecobuild Product Search
Mastic Asphalt News - Ecobuild
HANSE HAUS Buyer Guide - Ecobuild
Top ten reasons to specify STYROFOAM XPS in inverted roofing
Specify With Confidence - Phase-A-Matic, Inc.
GREEN BUILDINGS GUIDE: SpEcIfyING paRchEm pRoDUctS
Energy-Roof brochure - Ecobuild Product Search
Micronal PCM Brochure - Ecobuild Product Search
Solar Thermal Tiles - Ecobuild Product Search
Βιοκλιματική Δόμηση - Eco - building Club
IN_Dec_18_Final_SP
Refurb Projects - October 2016
Architectural Record 2015-06
Electric Underfloor Heating Solutions - Building Products Index
specifier UPDATE - Accuride