Operating Results December 2017

334

NEWS

Plant name Country Nominal

capacity

Type

gross

[MW]

net

[MW]

Operating

time

generator

[h]

Energy generated. gross

[MWh]

Month Year Since

commissioning

Time availability

[%]

Energy availability

[%] *) Energy utilisation

[%] *)

Month Year Month Year Month Year

OL1 Olkiluoto BWR FI 910 880 744 677 427 7 422 331 254 654 186 100.00 94.62 99.13 93.24 100.06 93.11

OL2 Olkiluoto BWR FI 910 880 744 687 897 6 482 042 244 299 181 100.00 81.41 99.91 80.52 101.60 81.31

KCB Borssele PWR NL 512 484 744 381 468 3 402 478 158 206 919 99.89 76.34 99.89 76.67 100.45 74.52

KKB 1 Beznau 1,2,7) PWR CH 380 365 0 0 0 124 746 087 0 0 0 0 0 0

KKB 2 Beznau 7) PWR CH 380 365 744 285 817 2 932 717 131 164 873 100.00 88.29 100.00 87.83 101.09 87.42

KKG Gösgen 7) PWR CH 1060 1010 744 795 652 8 583 952 305 194 587 100.00 93.02 99.99 92.67 100.89 92.44

KKM Mühleberg BWR CH 390 373 744 287 210 3 125 900 124 338 145 100.00 92.90 99.74 92.30 98.98 91.50

CNT-I Trillo PWR ES 1066 1003 744 789 963 8 530 707 239 024 424 100.00 92.10 100.00 91.83 99.16 90.86

Dukovany B1 PWR CZ 500 473 744 363 432 2 820 108 108 630 483 100.00 65.98 97.72 65.46 97.70 64.39

Dukovany B2 PWR CZ 500 473 700 349 496 3 299 909 104 622 538 94.09 76.84 93.68 76.31 93.95 75.34

Dukovany B3 PWR CZ 500 473 744 373 964 2 997 571 102 622 427 100.00 77.81 100.00 68.84 100.53 68.44

Dukovany B4 PWR CZ 500 473 744 371 658 2 743 590 103 271 741 100.00 71.76 100.00 62.75 99.91 62.64

Temelin B1 PWR CZ 1080 1030 189 188 794 8 853 135 106 481 294 25.40 93.66 25.24 93.61 23.50 93.58

Temelin B2 PWR CZ 1080 1030 744 806 383 7 625 624 101 489 946 100.00 80.18 99.98 79.88 100.36 80.60

Doel 1 PWR BE 454 433 744 324 212 3 601 775 134 214 747 100.00 91.55 95.55 90.68 95.68 90.33

Doel 2 PWR BE 454 433 744 330 500 3 598 619 132 252 268 100.00 92.13 97.01 91.54 97.48 89.99

Doel 3 PWR BE 1056 1006 0 0 6 732 621 251 169 221 0 72.26 0 72.10 0 72.40

Doel 4 PWR BE 1084 1033 744 818 714 7 873 391 254 545 842 100.00 84.51 100.00 83.82 100.49 82.19

Tihange 1 PWR BE 1009 962 744 760 691 3 575 802 290 838 876 100.00 41.96 100.00 41.23 101.59 40.46

Tihange 2 PWR BE 1055 1008 744 792 848 7 430 470 248 949 538 100.00 83.93 100.00 80.45 101.66 80.76

Tihange 3 PWR BE 1089 1038 740 799 873 9 414 133 268 894 830 99.43 99.74 98.50 99.59 98.65 98.58

Operating Results February 2018

Plant name

Type

Nominal

capacity

gross

[MW]

net

[MW]

Operating

time

generator

[h]

Energy generated, gross

[MWh]

Time availability

[%]

Energy availability

[%] *) Energy utilisation

[%] *)

Month Year Since Month Year Month Year Month Year

commissioning

KBR Brokdorf DWR 1480 1410 672 896 786 1 854 307 342 046 366 100.00 100.00 93.97 93.97 89.88 88.15

KKE Emsland DWR 1406 1335 672 952 068 1 962 705 337 285 988 100.00 100.00 100.00 100.00 100.88 98.60

KWG Grohnde 1,2) DWR 1430 1360 554 750 245 1 727 583 368 355 162 82.44 91.67 77.64 86.68 77.60 84.79

KRB C Gundremmingen SWR 1344 1288 672 908 675 1 890 834 322 470 727 100.00 100.00 99.41 99.72 100.04 98.75

KKI-2 Isar DWR 1485 1410 672 1 000 793 2 083 701 343 682 024 100.00 100.00 100.00 99.99 100.09 98.84

KKP-2 Philippsburg DWR 1468 1402 672 981 334 2 043 937 357 211 453 100.00 100.00 100.00 99.96 98.08 97.02

GKN-II Neckarwestheim DWR 1400 1310 672 946 400 1 952 600 322 075 734 100.00 100.00 100.00 99.68 101.03 98.81

*)

Net-based values

(Czech and Swiss

nuclear power

plants gross-based)

1)

Refueling

2)

Inspection

3)

Repair

4)

Stretch-out-operation

5)

Stretch-in-operation

6)

Hereof traction supply

7)

Incl. steam supply

8)

New nominal

capacity since

January 2016

9)

Data for the Leibstadt

(CH) NPP will

be published in a

further issue of atw

BWR: Boiling

Water Reactor

PWR: Pressurised

Water Reactor

Source: VGB

construction of the plant. It is yet

another proof of the quality of our I&C

solutions”, said Frédéric Lelièvre,

Framatome’s Senior Executive Vice

President in charge of Sales, Regional

Platforms and the Instrumentation

and Control Business Unit.

“We see the implementation of

TELEPERM XS and different functional

improvements as a big step

forward to operate safely until the end

of lifetime of our power plant”, said

Jack de Waal, Project Manager at EPZ.

The Borssele pressurized water

reactor is the only operating nuclear

power plant in the Netherlands. The

plant was connected to the grid in

1973 and has a net electric output of

482 megawatt. In 2006, the Dutch

authorities approved a prolonged

operation until 2034.

| | (181061143), www.framatome.com

Market data

(All information is supplied without

guarantee.)

Nuclear Fuel Supply

Market Data

Information in current (nominal)

U.S.-$. No inflation adjustment of

prices on a base year. Separative work

data for the formerly “secondary

market”. Uranium prices [US-$/lb

U 3 O 8 ; 1 lb = 453.53 g; 1 lb U 3 O 8 =

0.385 kg U]. Conversion prices [US-$/

kg U], Separative work [US-$/SWU

(Separative work unit)].

January to December 2014

• Uranium: 28.10–42.00

• Conversion: 7.25–11.00

• Separative work: 86.00–98.00

January to December 2015

• Uranium: 35.00–39.75

• Conversion: 6.25–9.50

• Separative work: 58.00–92.00

2016

January to June 2016

• Uranium: 26.50–35.25

• Conversion: 6.25–6.75

• Separative work: 58.00–62.00

July to December 2016

• Uranium: 18.75–27.80

• Conversion: 5.50–6.50

• Separative work: 47.00–62.00

2017

January to June 2017

• Uranium: 19.25–26.50

• Conversion: 5.00–6.75

• Separative work: 42.00–50.00

July to December 2017

• Uranium: 19.50–26.00

• Conversion: 4.50–6.00

• Separative work: 39.00–43.00

News