Purelux Catalogue 2018

emryn.bense

Catalogue 2018

trading

Product Catalogue 2018

031 569 3573 | info@pureluxtrading.com | www.pureluxtrading.com


2

trading


index

Standard Range - Fluorescent Luminaires

Channel Fluorescent Luminaires................................................................................................................ 04

High Bay Fluorescent Luminaires .............................................................................................................. 06

Industrial Vapour Proof Luminaires ........................................................................................................... 08

Parabolic Louvered Fluorescent Luminaires Surface ................................................................................. 10

Double Parabolic Fluorescent Luminaires Recessed .................................................................................. 12

Single Parabolic Fluorescent Luminaires Recessed .................................................................................... 14

Prismatic Fluorescent Luminaires Surface.................................................................................................. 16

Prismatic Fluorescent Luminaires Recessed .............................................................................................. 18

recessed led panel - Luminaires

LED Panel - Recessed Luminaires............................................................................................................... 20

Standard range - led bulkheads

LED Bulkhead.............................................................................................................................................. 23

15w Ceiling Light ....................................................................................................................................... 25

15w Energy Saving Bulkhead ..................................................................................................................... 26

downlights

5w LED Downlight ..................................................................................................................................... 27

standard floodlight range

LED Floodlight............................................................................................................................................. 28

control gear - occupancy sensors

Microwave Sensor ..................................................................................................................................... 32

emergency range - led luminaires

LED Exit Sign............................................................................................................................................... 34

Emergency Light Kit ................................................................................................................................... 36

lighting accessories

LED fashion wind desklamp ....................................................................................................................... 37

Legal Requirements & Guidelines ........................................................................................... 38

trading

3


standard range - fluorescent luminaires

Channel Fluorescent Luminaires

[PL/OPC Range]

FEATURES:

• Robust steel body with powder coated

paint finish

• T5 Lamps

• 28W or 54W

• Energy efficient

• Premium Branded Electronic Control Gear

• Warm Start

• PF = 0.95

• Suitable for use with occupancy sensors

• Easy to install

• Emergency conversion kits (optional)

Applications: Parking bays | Retail stores | General interior | Canopy

The PL/OPC range of channel luminaires are designed to drive T5 or T8 fluorescent tubes. The body is manufactured in

steel and finished in a white gloss powder coat.

These open channels have been designed and manufactured for surface plaster-board and concrete ceiling structure

installations including under-counter, bulkhead, pelmet, display lighting, parking bays and retail stores etc.

These luminaires meet the demands of the architect, electrical engineer, client and comply with SABS safety specifications

(SANS 60598).

channel fluorescent luminaire SpecificationS

Type:

Open channel luminaire

Voltage:

230V +3%/-10% 50Hz

Power: T5 - 28/49W, T8 - 36/58W

Power factor: >0.9

Body colour:

Gloss white (powder coat)

Material:

Mild steel

Options:

Emergency lighting conversion

Warranty:

3 years (control gear only)

Conformance: IEC/SANS 60598-1

4

trading


standard range - fluorescent luminaires

photometric data:

Open Channel Fluorescent Luminaires

Item Unit Size (L x W x H - mm) Box Size (mm) Cut-out Weight kg’s

T5 1x28/54W 1180 x 40 x 30 1200 x 50 x 50 N/A 0.8

T5 1x35/49W 1480 x 40 x 30 1500 x 100 x 50 N/A 0.9

T5 1x80W 1480 x 40 x 30 1500 x 100 x 18 N/A 1.1

T8 2x36W 1270 x 80 x 35 1285 x 100 x 50 N/A 1.0

T5 2x35/49W 1480 x 75 x 40 1500 x 190 x 180 N/A 1.4

T8 2x58W 1540 x 40 x 50 1550 x 210 x 130 N/A 1.5

trading

5


standard range - fluorescent luminaires

High Bay Fluorescent Luminaires

[PL/TB Range]

FEATURES:

• T5 fluorescent lamps

• Premium Branded Electronic Control Gear

• PPMA transparent lens cover

• Very wide, even, light distribution

• Emergency conversion kits (optional)

• Up to 58% energy saving

• 95% maintained light output over lamp life

• 50 000-hour average lamp life ratings

• Instant on (Improved Safety)

• No Flicker - ballast operates at high frquency

• Suitable for use with occupancy sensors

• Exceptional colour rendering

Applications: Factories | Warehousing | Offices | Workshops | Hospitals

Until recently, high-intensity discharge (HID) lighting systems were considered the only high-bay lighting option. However,

recent advances in fluorescent lighting systems now make these lower-cost systems more attractive choices for high-ceiling

applications and can reduce energy costs by up to 50%.

High-bay applications are often found in warehouses, schools, gymnasiums, storage rooms, large retail stores and other

building types with ceilings 15ft and above. These fixtures provide the best of both worlds; efficiency and high-quality light.

These lensed linear fluorescent fixtures for industrial and commercial applications are available in four lamp configurations

(using T5 lamps). Supplied with a high efficiency aluminium reflector with 95% reflectance. Die-formed, 20 gauge, cold-rolled

steel housing and cover. Full-frame door has a clear plastic lens. Fixture installs with chain, surface or pendant mount. It also

has access for 3/4-inch conduit and wire entry as well as being configured for hard wiring.

T5 (Warm Start) fixture utilizes four 54W fluorescent lamps (not included). All metal parts pre-treated with a phosphate

bonding process and post-painted with an electrostatically-applied high temperature baked white enamel for superior quality

and durability.

HIGH-BAY FLUORESCENT LUMINAIRE SPECIFICATIONS

Type:

High bay fluorescent luminaire

Features:

95% efficiency reflector - plastic lens cover

Control gear:

Premier branded gear only

Voltage:

230V +3%/-10% 50Hz

Power:

T5 - 4 x 54W

Power factor: >0.9

Body colour:

Gloss white (powder coat)

Material:

Mild steel

Options:

Emergency lighting conversion

Warranty:

3 years (control gear only)

Conformance: IEC/SANS 60598-1

6

trading


standard range - fluorescent luminaires

high bay / t-bay Fluorescent Luminaires

Item Unit Size (L x W x H - mm) Box Size (mm) Cut-out Weight kg’s

T5 4x54W 1200 x 420 x 100 1210 x 440 x 225 N/A 5.0

T5 4x80W 1480 x 430 x 100 1510 x 435 x 225 N/A 7.7

trading

7


standard range - fluorescent luminaires

Industrial Vapourproof

Fluorescent Luminaires

[PL / FL / S / VP RANGE]

FEATURES:

• Body diffuser is injected moulded, flame

retardant polycarbonate material

• Warm start electronic ballast

• Stainless steel gear tray

• Stainless steel latches (optional extra)

• Mounting facility through external brackets

• Hinged prismatic diffuser for ease of lamp

replacement

• Ingress protection - IP65

• Suitable for use with occupancy sensors

• Hinged glass lens retaining frame for ease

of lamp replacement

• Emergency conversion (optional)

applications: For wet environments with high ingress protection

Food Processing | Public Buildings | Car Parks | Schools | Damp Environments | Corrosive Environments

The luminaire consists of an injection-moulded flame-retardant polycarbonate housing and prismatic diffuser. The powder

coated white reflector and control gear tray, upon which all electrical components are mounted, are secured by means of

multiple twist lock latches to secure the reflector to the housing. The silicon sponge seal is moulded into the housing to ensure

an optimal seal between the housing and the prismatic diffuser. It is designed to operate fluorescent lamps from T5 or

T8 lamps.

The Luminaire has a degree of protection that complies with SANS 60598-2-1. Lamp compartment: IP65 Gear compartment:

IP65

Type:

Features:

IP Rating:

Control gear:

Voltage:

Power:

SPECIFICATIONS

VapourProof fluorescent luminaire

Flame-retardant polycarbonate.

Stainless steel securing clips. Hinged lamp cover.

IP65

Premier branded gear only

230V +3%/-10% 50Hz

2 x 18W up to 2 x 49W

Power factor: >0.9

Body colour:

Material:

Options:

Warranty:

Gloss white (powder coat)

Flame retardant polycarbonate

Emergency lighting conversion

3 years (control gear only)

Conformance: IEC/SANS 60598-1

8

trading


standard range - fluorescent luminaires

industrial vapour proof

Item Unit Size (L x W x H - mm) Box Size (mm) Cut-out Weight kg’s

T5 2x14W 660 x 130 x 90 675 x 140 x 70 N/A 1.0

T8 2x18W 660 x 130 x 90 675 x 140 x 70 N/A 1.0

T8

1x36W

1x28w

T5-T8

2x35W

2x49W

2x58W

1270 x 80 x 90 1275 x 100 x 70 N/A 1.4

1580 x 130 x 90 1580 x 150 x 70 N/A 2.5

T5-T8

1x49W

1x58W

T5-T8

2x28W

2x36W

2x54W

1560 x 85 x 90 1570 x 100 x 70 N/A 2.0

1270 x 130 x 90 1570 x 150 x 70 N/A 2.2

trading

9


standard range - fluorescent luminaires

Parabolic Louvered

Fluorescent Luminaires - Surface

[PL / FL / S / DB RANGE]

FEATURES:

• Louvered luminaires - surface mount

• Robust steel body with powder coated

paint finish

• T5 Lamps

• 2 x 28/54W, 2 x 35/49W

• 99.9% pure double parabolic low

iridescent clip-in aluminium reflector

• 25% less energy consumption

• Electronic control gear

• Warm start top-branded ballast

• Power Factor > 0.9

• Suitable for use with occupancy sensors

• Easy to install

• Complies with SANS 60598-1 Safety

• Emergency conversion kits (optional)

applications: Offices | Schools | Banks | Hospitals

The PL/FL/S/DB range of louvered luminaires are supplied as a surface luminaire with aluminium louvres and designed to

take T5 fluorescent tubes. The body is manufactured in steel and finished with a white gloss powder coating.

The slim depth of the fitting is accentuated by being slightly spaced off the ceiling and having gently sloping sides.

T5 & T8 lamps and electronic ballasts ensure 25% less energy consumption than switched-start systems. High frequency

control gear gives maximum efficiency, energy saving and quality of light. The ECG has ‘warm’ start which benefits the high

frequency fitting, giving flicker free and silent operation.

Specifications

Type:

Low-brightness surface-mount fluorescent luminaire

Features:

95% reflectance reflector.

Suitable for use with occupancy sensors.

IP Rating:

IP22

Control gear:

Premier branded gear only

Voltage:

230V +3%/-10% 50Hz

Power: 2 x 28/54W, 2 x 35/49W

Power factor: >0.9

Body colour:

Gloss white (epoxy powder coat)

Material:

Mild steel

Options:

Emergency lighting conversion. Switch start gear.

Warranty:

3 years (control gear only)

Conformance: IEC/SANS 60598-1

10

trading


standard range - fluorescent luminaires

double parabolic fluorescent luminaires - surface

Item Unit Size (L x W x H - mm) Box Size (mm) Cut-out Weight kg’s

T5 3x14W 600 x 600 x 60 620 x 620 x 120 N/A 2.6

T5 2x28/54W 1200 x 300 x 60 1215 x 315 x 130 N/A 3.0

T5 2x35/49W 1500 x 300 x 60 1515 x 315 x 130 N/A 3.4

trading

11


standard range - fluorescent luminaires

Double Parabolic Fluorescent Luminaires

Recessed [PL / LR / DP RANGE]

FEATURES:

• Double parabolic luminaire – recessed

• Robust steel body with powder coated finish

• 99.9% pure, double parabolic, low iridescent

clip-in aluminium reflector

• 2 x 14/24W, 2 x 28/54W

• Premium Branded Electronic Control Gear

• Suitable for use with occupancy sensors

• 25% less energy consumption

• Warm start

• PF > 0.9

• Complies with SABS 60598-1 safety

• Emergency conversion kits (optional)

The PL/L/D range of louvred luminaires are supplied as recessed luminaires with polished aluminium wedge louvres and designed

to take T5 and T8 fluorescent tubes. The body is manufactured in steel and finished in a white gloss powder coat.

Ideal for work environments with video display terminals. Louvre with broad, symmetrical batwing light distribution, featuring longitudinal

reflectors and double parabolic transverse blades, in anodized anti-iridescent 99.90% pure aluminium with mirror finish.

Direct longitudinal and transverse luminance less than 200 cd/m2 for vertical angles over 60°.

T5 lamps and electronic ballasts ensure 25% less energy consumption than switched-start systems. High frequency control gear

gives maximum efficiency, energy saving and quality of light. The top-branded ballasts have ‘warm’ start which benefits the high

frequency fitting, giving flicker free and silent operation.

Type:

applications: Offices | Schools | Banks | Hospitals

SPECIFICATIONS

Double parabolic recessed fluorescent luminaire

Features:

95% reflectance reflector.

Suitable for use with occupancy sensors.

IP Rating:

IP22

Control gear:

Premier branded gear only

Voltage:

230V +3%/-10% 50Hz

Power:

2x14/24W, 2x28/54W

Power factor: >0.9

Body colour:

Gloss white (epoxy powder coat)

Material:

Mild steel

Options:

Emergency lighting conversion.

Switch start gear.

Warranty:

3 years (control gear only)

Conformance: IEC/SANS 60598-1

12

trading


standard range - fluorescent luminaires

Photometric Data

Gamma Angle

T5 2x24W

120

105

105

90

90

75

75

60

60

45

45

30 15 0 15

30

double parabolic fluorescent luminaires - recessed

Item Unit Size (L x W x H - mm) Box Size (mm) Cut-out Weight kg’s

T5 2x14/24W 600 x 600 x 60 670 x 615 x 125 570 x 570 2.9

T5 2x28/54W 1200 x 600 x 60 1245 x 615 x 215 1170 x 570 5.4

trading

13


standard range - fluorescent luminaires

Single Parabolic Fluorescent Luminaires

Recessed [PL / LR / S RANGE]

FEATURES:

• Single parabolic luminaires - recessed

• Robust steel body

• Powder coated paint finish

• 3 x 14/24W, 2 x 28/54W

• SABS compliant

• Tubes and control gear easily accessible

• Easy to install

• 25% less energy consumption

• Premium Branded Electronic Control Gear

• PF = 0.95

• Emergency conversion kits (optional)

applications: Offices | Schools | Banks | Hospitals

The PL/LR/S range of louvred luminaires (Low Brightness Reflectors - LBR’s) are supplied as recessed luminaires with aluminium

louvres and design to take T5 fluorescent tubes. The body is manufactured in steel and finished in a white gloss powder

coat.

This is a quality recessed luminaire designed for plasterboard ceilings. The fitting can be used for most applications such as

offices, schools, banks, hospitals etc. as it gives quality and effective lighting.

T5 & T8 lamps and electronic ballasts ensure 25% less energy consumption than conventional systems. High frequency control

gear gives maximum efficiency, energy saving and quality of light. The ECG has ‘warm’ start which benefits the high frequency

fitting, giving flicker free and silent operation.

Specifications

Type:

Low-brightness, single parabolic recessed

fluorescent luminaire.

Features:

95% reflectance reflector.

Suitable for use with occupancy sensors.

IP Rating:

IP22

Control gear:

Premier branded gear only

Voltage:

230V +3%/-10% 50Hz

Power: 3 x 14/24W, 3 x 28/54W

Power factor: >0.9

Body colour:

Gloss white (epoxy powder coat)

Material:

Mild steel

Options:

Emergency lighting conversion.

Switch start gear.

Warranty:

3 years (control gear only)

Conformance: IEC/SANS 60598-1

14

trading


standard range - fluorescent luminaires

Photometric Data

T5 3x14W

T5 3x28W

Gamma Angle

120

Gamma Angle

120

105

105

105

105

90

90

90

90

75

75

75

75

60

60

60

60

45

45

45

45

30 15 0 15

30

30 15 0 15

30

single parabolic fluorescent luminaires - recessed

Item Unit Size (L x W x H - mm) Box Size (mm) Cut-out Weight kg’s

T5 3x14/24W 600 x 600 x 60 640 x 615 x 125 570 x 570 2.7

T5 3x28/54W 1200 x 600 x 60 1245 x 615 x 215 1175 x 570 4.9

trading

15


standard range - fluorescent luminaires

Prismatic fluorescent luminaires

Surface [PL / FL / S / SD RANGE]

FEATURES:

• Prismatic lens luminaire (surface mount)

• Robust steel body with powder coated

paint finish

• 2 x 28/54W and 2 x 49W - T5 OR 2/36W T8

• Tubes and control gear easily accessible

• Easy to install

• Top branded control gear

• Warm Start - suitable for use with

occupancy sensors

• PF = 0.95

• Complies with SANS 60598-2-1 safety mark

• Emergency conversion kits (optional)

applications: Offices | Schools | Supermarkets | Hospitals

The PL/FL/S/SD range of prismatic luminaires are supplied as a surface-mounting T5 fluorescent lamp luminaire with prismatic

lens. The body is manufactured in steel and finished in white gloss powder coat. Top-branded control gear ensures that it

may be used with occupancy sensors.

Type:

Features:

IP Rating:

Control gear:

Voltage:

Power:

Specifications

Prismatic lens fluorescent luminaire

(surface mount)

Suitable for use with occupancy sensors

IP22

Premier branded gear only

230V +3%/-10% 50Hz

2/36W-T8,2 x 28/54W and 2 x 35/49W - T5

Power factor: >0.9

Body colour:

Material:

Options:

Warranty:

Gloss white (epoxy powder coat)

Mild steel

Emergency lighting conversion.

Switch start gear.

3 years (control gear only)

Conformance: IEC/SANS 60598-1

16

trading


standard range - fluorescent luminaires

prismatic fluorescent luminaires - surface

Item Unit Size (L x W x H - mm) Box Size (mm) Cut-out Weight kg’s

T8 2x36W 1235 x 175 x 65 1250 x 340 x 195 N/A 2.0

T5 2x28/54W 1235 x 175 x 65 1250 x 340 x 195 N/A 2.0

T5 2x35/49W 1500 x 175 x 85 1515 x 340 x 195 N/A 2.0

T8 1x58W 1540 x 100 x 85 1550 x 280 x 225 N/A 1.9

trading

17


ecessed led panel - luminaires

LED Panel Luminaire

Recessed [PL / LED / PNL Range]

FEATURES:

• Light emitting diodes (LED)

• High efficiency: 40-60% less energy consumption

compared to fluorescent alternatives.

• Drop-in replacement of old T5 / T8 fixtures.

• Long life - lower miniatous costs

• High quality light, high colour-ending, less heat,

no UV or IR radiation.

• 6W - 72W versions

• Lumens: 1280 - 6500

• Power factor > 0.95

• Colour Rendering Index: >0.75

• 600x600, 1200x600, options

• Cool white or warm white options

• Eco-friendly: no mercury content

• Low operating temperature

applications: Offices | Schools | Shopping Malls | Hospitals | Banks

Light Emitting Diodes (LED’s) are rapidly replacing many traditional light sources such as incandescent, fluorescent and HID

lamps. Rapid advances in LED science are yielding unheard-of efficiencies and reliabilities. This translates into lower electricity

consumption, lower temperatures and longer life. Most new installations are switching to LED lighting. The range of LED

panel luminaires are now available to be used as retrofits for the aging T8 and in many cases, the T5 fittings. LED panel lights

are designed for a glare-free light effect widely used in homes, hotels, hospitals, shopping malls, offices, schools and conference

rooms (ceiling recessed, pendant, ceiling mounted, wall mounted and so on).

Specifications

Type:

LED Panel luminaire (recess mount)

Features:

Suitable for use with occupancy sensors

IP Rating:

IP22

Control gear:

Premier branded gear only

Voltage:

230V +3%/-10% 50Hz

Power factor: >0.9

Body colour:

Gloss white

Material:

Main materials; aluminium oxide frame.

Plastic light pipe.

Options:

Emergency lighting conversion.

Warranty: 3 years (control gear only)

Colour temp:

WW(4500K), CW(6500K)

Installation options:

surface mounted, recessed mounted or suspended

Conformance: IEC/SANS 60598-1

18

trading


ecessed led panel - luminaires

Photometric Data

18W

36W

90 -90

78

150

231

312

90 -90

280

560

810

1120

0

390

0

1400

42W

72W

90 -90

300

600

900

1200

90 -90

120

810

126

1080

0

1500

0 2100

trading

19


ecessed led panel - luminaires

led panel

Item Unit Size (L x W x H - mm) Box Size (mm) Cut-out Weight kg’s

6500K 1200 x 600 x 10 1280 x 680 x 40 N/A 5.2

4500K 1200 x 600 x 10 1280 x 680 x 40 N/A 5.2

6500K 600 x 600 x 10 740 x 680 x 80 N/A 2.6

4500K 600 x 600 x 10 740 x 680 x 80 N/A 2.6

5000K 36W 600 x 600 x 10 640 x 680 x 40 N/A 2.9

5000K 48W 600 x 600 x 10 1250 x 350 x 40 N/A 3.0

PL127 6W

4500K

PL127 9W

4500K

PL127 12W

4500K

PL127 18W

4500K

PL127 18W

4500K SQ

120 x 15 155 x 125 x 25 100 0.2

150 x 15 120 x 220 x 25 130 0.2

170 x 15 205 x 195 x 50 150 0.3

225 x 15 300 x 235 x 30 200 0.4

225 x 225 x 15 280 x 230 x 30 200 x 200 0.5

PL127

surface

12W

170 x 35 180 x 180 x 40 N/A 0.4

20

trading


standard range - led bulkheads

LED Bulkhead

PL / LED / BLK Range

FEATURES:

• Designed for decorative and efficient

bulk-head lighting applications in modern

architectural environments.

• 12W,18W & 24Wversions

• Wall or ceiling mounted

• Long life of up to 30 000 hours

• Zero maintenance costs

• IP 65 rated

• Slim-line - Ultra thin

• ABS plastic base

• Low cost

• Occupancy sensor option

• Emergency conversion kits (optional)

applications: Commercial | Retail Areas | Shopping Malls | Public Buildings

The luminaire base is designed with a structured clear high impact acrylic diffuser. It is circular in shape and is designed to

operate 12W,18W& 24W LED’s. The luminaire has a degree of protection that complies with SANS 60598-2-1; lamp compartment;

IP 65.

Specifications

Type:

Features:

IP Rating:

Control gear:

Voltage:

LED Bulkhead

Suitable for use with occupancy sensors

IP65

Premier branded gear only

230V +3%/-10% 50Hz

Power factor: >0.9

Body colours:

Material:

Options:

Warranty:

White or black

ABS Plastic body, polycarbonate lens

Emergency lighting conversion

Switch start gear

Occupancy sensor

3 years (control gear only)

Conformance: IEC/SANS 60598-1

trading

21


standard range - led bulkheads

Photometric Data

18W Lamp Configuration

0° cd/1000lm

270°

90°

160

120

200

180°

technical specifications

parameter pl/led/blk/12 pl/led/blk/18w

Power 220 - 240 Volts 220 - 240 Volts

Weight 0.9kg 1.5kg

Comparable Light Source 28W 2D Lamp 45W 2D Lamp

Line Frequency 50 - 60 Hertz 50 - 60 Hertz

Design Life 50 000 hours 50 000 hours

Power Consumption 12W 18W

Total Lumens 1000 LM 1650 LM

Beam Angle 360° 360°

led bulkhead

Item Unit Size (L x W x H - mm) Box Size (mm) Cut-out Weight kg’s

18W Bulkhead 335 x 120 350 x 350 x 175 N/A 1.4

10W Rib-faced

Bulkhead

185 x 100 195 x 195 x 11 N/A 0.6

22

trading


standard floodlight range - led luminaires

LED Floodlight

PL / LED / FLD Range

FEATURES:

• 10 - 200W (Bridgelux) LED options

• Service life; >- 30 000 hours

• IP65 rating

• Luminous flux 900-6480 lm

• Colour temperature 2700 - 7000 K

• Beam angle 120°

• High efficiency

• Colour rendering index (CRI) RA > 68-75

• Efficiency of driver > 80%

• Diecast aluminium alloy

• Emergency conversion kits (optional)

applications: Shopping Centres | Schools | Public Buildings | Hotels

advantages of led floodlights

1. The high lumen chips ensures the luminaire efficiency can reach 100lm/W.

2. UL listed IP65 driver

3. Very easy and convenient for installation, can be used as floodlights, tunnel lights, canopy lights,

parking lot lights, billboard lighting etc.

4. 30 000 hour life span

5. Low power consumption, long life, good stability and high reliability.

6. Cold light source design

7. Green technology - energy efficient lighting.

8. No radiation, no lead, no mercury or other polluting elements.

Specifications

Type:

IP Rating:

Control gear:

Voltage:

LED Floodlight

IP65

Premier branded gear only

230V +3%/-10% 50Hz

Power factor: >0.9

Body colour:

Material:

Warranty:

Black

Diecast aluminium alloy

1 year

Conformance: IEC/SANS 60598-1

trading

23


standard floodlight range - led luminaires

technical specifications

parameter 10w 20w 30w 50w 80w

Input Voltage 85-265Vac 85-265Vac 85-265Vac 85-265Vac 85-265Vac

Frequency Range 50-60Hz 50-60Hz 50-60Hz 50-60Hz 50-60Hz

Power Factor > 0.9 > 0.9 > 0.9 > 0.9 > 0.9

Power Efficiency > 85% > 85% > 85% > 85% > 85%

LED Working Voltage DC30-36V DC30-36V DC30-36V DC30-36V DC30-36V

LED Quantity

Bridgelux

LED chip

Bridgelux

LED chip

Bridgelux

LED chip

Bridgelux

LED chip

Bridgelux

LED chip

LED Consumption 10w 20w 30w 50w 80w

System Consumption 12W 22W 33W 55W 85W

LED Luminous

Efficiency

100-110lm/W 100-110lm/W 100-110lm/W 100-110lm/W 100-110lm/W

WW 900Lm WW 1800Lm WW 2700Lm WW 4050Lm WW 6480Lm

LED Initial Flux

PW 945Lm PW 1890 Lm WW 2835Lm WW 4500Lm WW 7200Lm

CW 990Lm CW 1980Lm CW 2970Lm CW 4750Lm CW 7600Lm

Lamps efficiency > 90% > 90% > 90% > 90% > 90%

(Height)

2M - 27.7Lux

(Height)

2M - 51.8Lux

(Height)

4M - 26Lux

(Height)

6M - 40Lux

(Height)

6M - 70Lux

Average Illuminance

(Height)

3M - 12.3Lux

(Height)

3M - 23.0Lux

(Height)

5M - 7.5Lux

(Height)

8M - 28Lux

(Height)

8M - 54Lux

(Height)

4M - 6.92Lux

(Height)

4M - 12.9Lux

(Height)

6M - 6.5Lux

(Height)

10M - 19Lux

(Height)

10M - 36Lux

(Height)

2M - 3.7m

(Height)

2M - 4.5m

(Height)

4M - 3.3m

(Height)

6M - 18.0m

(Height)

6M - 18.0m

Illuminance Area

(Height)

3M - 5.6m

(Height)

3M - 6.8m

(Height)

5M - 6.5m

(Height)

8M - 23.0m

(Height)

8M - 23.0m

(Height)

4M - 7.5m

(Height)

4M - 9.4m

(Height)

6M - 9.8m

(Height)

10M - 29.0m

(Height)

10M - 29.0m

Illuminance

Uniformity

>0.6 >0.6 >0.6 >0.6 >0.6

WW 2700 - 3700K WW 2700 - 3700K WW 2700 - 3700K WW 2700 - 3700K WW 2700 - 3700K

Colour Temperature

PW 5500 - 6500K PW 5500 - 6500K PW 5500 - 6500K PW 5500 - 6500K PW 5500 - 6500K

CW 6500 - 7000K CW 6500 - 7000K CW 6500 - 7000K CW 6500 - 7000K CW 6500 - 7000K

24

trading


standard floodlight range - led luminaires

technical specifications

parameter 10w 20w 30w 50w 80w

Colour rendering Index

WW Ra>68 WW Ra>68 WW Ra>68 WW Ra>68 WW Ra>68

PW & CW Ra>75 PW & CW Ra>75 PW & CW Ra>75 PW & CW Ra>75 PW & CW Ra>75

Light Distribution

Symmetric

expression / round

spot

Symmetric

expression /

round spot

Symmetric

expression /

round spot

Symmetric

expression /

round spot

Symmetric

expression /

round spot

Light Design

LED +

Reflector double

distribution

LED +

Reflector double distribution

LED +

Reflector double distribution

LED +

Reflector double distribution

LED +

Reflector double distribution

LED Junction

Temperature


standard floodlight range - led luminaires

floodlights

Item Unit Size (L x W x H - mm) Box Size (mm) Cut-out Weight kg’s

PL111 10W 130 x 120 x 40 155 x 120 x 50 N/A 0.5

PL111 20W 185 x 155 x 45 200 x 160 x 50 N/A 2.1

PL111 30W 230 x 195 x 50 255 x 210 x 60 N/A 1.3

PL111 50W 285 x 240 x 60 295 x 255 x 65 N/A 1.9

PL111 80W 370 x 290 x 100 415 x 315 x 125 N/A 4.1

PL111 100W 340 x 285 x 80 350 x 295 x 90 N/A 3.0

PL111 200W 375 x 355 x 90 380 x 360 x 100 N/A 5.3

BS114 30W 190 x 180 x 80 255 x 235 x 120 N/A 1.4

BS114 50W 230 x 195 x 95 280 x 300 x 135 N/A 2.1

50W 12V 285 x 230 x 140 300 x 250 x 155 N/A 2.6

26

trading


control gear - occupancy sensors

Microwave Sensor

Occupancy Sensors

FEATURES:

• Senses movment via the Doppler effect

• Omni-directional

• Switches lights HVAC on & off

• Saves energy from 25 - 75%

• Unsurpassed relay contact rating of 30A

• Radio frequency - microwave

• Detection through glass and thin walls

Applications: Industrial and domestic lighting energy saving

Occupancy sensors motion-sensing devices that automatically turn lighting on and off. Case studies have shown energy savings

from 25 - 75%.

Occupancy sensors should be a part of any modern lighting system because many rooms are left unoccupied for a significant

amount of time each day, typically with the lights on. Reducing the lighting load will result in measurable financial savings.

When occupants enter a room, the lights are automatically switched on. The lights remain on as the sensor detects the occupant’s

movements. When the occupant vacates the room the lights automatically switch off after a period of time.

The FX-MV360s2 in an active motion detector that emits a constant micro-wave frequency of 5.8GHz and detects movement

via the Doppler echo. The sensor can detect the slightest movement in its detection range. And, unlike PIR sensor types, there

are no blind spots.

Detection is possible through doors, panes of glass, thin walls and soft furnishings. These sensors are best suited for bathrooms,

toilets and areas with high possible air movement.

A daylight harvesting sensor prevents the lights from switching on if there is already enough natural light in the room.

Sensor settings include:

• Detection range

• Delay time

• Daylight harvesting level.

Occupancy sensors can save energy and extend the life of lamps, ballasts and control gear. Lighting controls will help reduce

energy by:

• Reducing the amount of power used during the peak demand period.

• Reducing room heat rise thereby reducing airconditioning energy costs.

trading

27


control gear - occupancy sensors

Power source

Power frequency

HF system

Time delay

microwave sensor SPECIFICATIONS

220 – 240Vac

50 – 60 Hz

5.8GHz CW radar (ISM band)

8 sec to 12 minutes

Detection angle 360°

Daylight harvesting

Rated load

30 lux (minimum setting) to daylight

(maximum setting)

(300 lux at 75% setting)

600W

Power consumption 0.9W

Weight

Detection range

Transmission power

67g

1 to 10 meters


emergency range - led luminaires

LED Exit Sign

PL / LED / EX

FEATURES:

• Provides up to 5 hours of emergency light

• Samsung LED chip

• Lamp type: 1 x 2W LED

• Die-cast aluminium housing

• White epoxy finish

• Slim-line / Super thin

• Low battery discharge protection

• Reverse battery Protection

Applications: Building regulatory exit-route indication

The Emergency Exit Sign range of luminaires is ideally suited as stand-alone / self-contained surface mounted fittings in new

or existing buildings, as required by regulations.

The Emergency Exit Sign housing is a white epoxy powder coated steel frame with a green “EXIT” legend. The LED lamp is protected

by a translucent opal polycarbonate diffuser that is attached to the body by means of specially designed and integral

clip mechanism.

The emergency exit sign contains a driver, 1x LED, associated control gear and ni-cad batteries for emergency power within the

exit sign. Connection to the mains is by means of an internal terminal connector. These luminaires are available in the following

versions: non-maintained, maintained or self-testing.

The LED arrangement provides a uniform illumination of the signs / legends with a high level of emergency illumination at floor

level or at the threshold of an exit door. 5 hours are provided of emergency lighting with the ni-cad batteries.

A safety start circuit is provided to prevent emergency operation until mains are connected. This enables installation without

disconnecting or unneccessarily depleting the batteries. Deep discharge protection is provided.

These Exit sign luminaires can also be connected to 12V or 24V dc central battery systems with maintained or non-maintained

operation.

Luminaires are constructed to ensure that the batteries are never subjected to a high ambient temperature which accelerates

the deterioration of the battery cells.

The exit signs fully satisfy the requirements os SANS 1186-1:2003 and SABS 0114-2 and are designed to conform to the SANS

1186-3:2004. The use of graphic symbols in conjunction with text and appropriate arrows enable easy recognition of escape

routes.

construction

All incoming wiring is terminated within a terminall block that is provided in the base. Normal and emergency control gear

is mounted on a plug-in removable gear tray. Knock-outs are provided in the top of the luminaire, with besa box mounting

facilities in the back.

Various alternative types of fixings are available (ie. ceiling or cantilever brackets etc.)

All luminaires are supplied with the appropriate lamps and the specified exit sign / legend.

trading

29


emergency range - led luminaires

exit signs

Item Unit Size (L x W x H - mm) Box Size (mm) Cut-out Weight kg’s

Exit Sign LRG 600 x 210 x 25 620 x 220 x 40 N/A 1.3

Exit Sign SML 355 x 145 x 25 365 x 165 x 50 N/A 1.7

technical specifications

Parameter

PL/LED/exit/2

Lamp Type

1 x 2w LED

Mains Voltage 230Vac +- 10%

Battery Type

1 x 2 Ahr Ni-cad cells

Lighting Duration

5 hours

Charging Current

150mA

Current Consumption

300mA

Maximum Ambient Temperature +70°

Type:

IP Rating:

Control gear:

Voltage:

Power:

Specifications

LED Bulkhead

IP22

Premier branded gear only

230V +3%/-10% 50Hz

300mA

Power factor: >0.9

Size:

Body colour:

Material:

Warranty:

Conformance:

Large: 600 x 210 x 25

Small: 355 x 145 x 25

Black

Diecast aluminium alloy

3 years (control gear only)

IEC/SANS 60598-1, SANS 0114-2 and SANS 1186 parts 1

and 3

30

trading


lighting accessories

LED fashion wind desklamp

FEATURES:

• Provides up to 2 hours of emergency light

• Samsung LED chip

• Lamp type: 1 x 2W LED

• White epoxy finish

• Slim-line / Super thin

• Low battery discharge protection

• Reverse battery Protection

led fashion wind desk lamp

Unit Size (L x W x H - mm) Box Size (mm) Cut-out Weight kg’s

110 x 100 x 375 205 x 125 x 105 N/A 0.2

trading

31


emergency lighting 101

Legal requirements and guidelines

It is important to be aware of legal requirements before undertaking an emergency escape lighting design. Two main instruments are of

interest to emergency lighting:

> The occupational health and safety act (OHS Act)

> South African Bureau of Standards (SABS) specifications

The OHS Act (85 of 1993), and act of parliament basically states that it is illegal not to have emergency lighting in the work place in areas

where failure of the normal mains supply may present a danger through low visability.

The compulsary specification (VC 8055) has been issued that calls various safety standards (including SANS 1464 part 22) making it illegal

for emergency lighting products not to comply with certain levels of safety and performance. Interestingly, because the emergency lighting

forms part of safety equipment, it must not only be designed to prevent shock or a fire hazard, it must also provide correct lighting

levels, lighting duration and other technical levels of performance.

The SABS offers internationally acceptable design guidelines to ensure the functionality and, probably more importantly for cash strapped

budgets, cost effectiveness of an emergency lighting solution.

In the event of an emergency, the emergency lighting systems must provide continuous illumination for a minimum of 90 minutes to allow

the occupants to safely exit the building. Emergency lighting systems must meet stringent criteria for construction and performance

against the occupational health and safety act (OHS Act). However, even though emergency lighting systems must meet these standards,

not all systems are created equally. There are applications in which certain systems should not be used. The mounting height, light source

and environment are very important to consider during installations. Some environmental issues to consider are temperature, dust, damp

or a wet location and a hazardous area.

The OHS Act requires an average of 1foot-candle upon initial illumination of the emergency light, and an average of not less than 0.6

foot-candle after a 90minute illumination period. Keeping that in mind, the proper choice of unit must be made to meet the foot-candle

requirement. The unit source of the unit used in an office with a mounting height of 7 - 9 feet will not work in a situation where the emergency

light is mounted 18 feet above the floor.

Many emergency lighting systems have lead acid batteries. These batteries generally have a 5 - 7 year life expectancy as long as it is

maintained in an operating temperature range of 60 - 80°F. As the temperature increases above 80°F, the life of the battery decreases dramatically.

When the temperature decreases, the battery life will increase, but the run-time of the battery will decrease, thus not allowing

the system to maintain the required 90 minute illumination. The sealed Nickel Cadmium maintenance-free battery is an alternate option

when it comes to temperature. These batteries offer a 12 to 15 year life with an operating range of -4 to 158°F. There are also re-fillable

lead acid and Nickel Cadmium batteries. These batteries require maintenance, but are great batteries to consider for temperature issues.

The lead acid battery has an expected life of 8 to 12 years if maintained in an operating environment of 32 to 105°F. The Nickel Cadmium

battery will have a life of 20 to 25 years, with an operating range of -22 to 140°F.

There are emergency lighting units that are specifically designed for dusty, damp and wet environments.An installer can not place any unit

into these situations and expect them to function as designed. Standard metal emergency lighting units will allow moisture and dust into

the enclosure. There have been situations where this has occured and the result is a shorter printed circuit board because the moisture

accumulated and dripped on the board components, or the dust from a metal grinding operation accumulated over time in the enclosure

that created a connection between components.

Hazardous environment units are again designed for their particular applications. The NEC developed Classes, Divisions and Groups for

these situations. Class I refers to areas where inflammable gases or vapours may be present in sufficient quantities to produce explosive

or flammable mixtures. Class II units are for areas where combustable dusts are present. Class III systems are for areas where ignitable

fibers are present in sufficient quantities to produce ignitable mixtures. Division I indicates an area where the hazardous condition is normally

present either continuously or periodically. Division II are areas where the hazardous condition is present due to accidental rupture,

breakage or unusual faulty operation of a dosed container or system. The groups are broken down by particular categories based on class.

Under Class I, Group A is for Acetylene, Group B for Hydrogen, Group C for Ether, Group D for Gasoline. Class II has Group E for Metal Dust,

Group F for Coal Dust and Group G for Grain Dust.

Emergency conversions are available for most Purelux luminaires. The advantages of using our fittings with factory fitted emergency

lighting equipment include the peace of mind that comes with the guarantee that applies to the entire luminaire and factory fitted units

installed under our quality assurance systems meeting the requirements of ICEL, BS and EN standards.

32

trading


fluorescent fittings featuring electronic ballasts

energy efficient fluorescent ballasts

The lighting industry has followed two paths in recent years towards the goal of improving fluorescent lamp efficiency.The first was a

“make it better” approach that optomised existing lamp and ballast perfomrance, with the focus on T-12 systems. That resulted in a 10

to 20% improvement in system efficacy.

The second approach - using solid-state electronics to provide high-frequency controlled power and optimum starting to fluorescent

lamps - has successfully increased lamp / ballast system efficacy by as much as 30-40% and added the capability of additional features at

low cost. These features include fluorescent lamp dimming, enhanced control capability and improved lamp life performance.

electronic ballasts

Electronic ballasts are more aptly, electronic high-frequency ballasts which increase lamp-ballasts efficacy, leading to increased energy

efficiency and lower operating costs without sacrificing light output. Electronic ballasts operate lamps using electronic switching power

supply circuits. These circuits take incoming 50-60Hz power (typically 120 or 277 volts) and convert it to high-frequency alternating current

(AC) in the range of 20 to 40 kHz. Electronic ballasts are more efficient than magnetic ballasts in converting input power to the proper

lamp power. Operating fluorescent lamps at higher frequencies reduces internal lamp losses resulting in an overall lamp-ballast system

efficacy of 15 to 20% compared to efficient electromagnetically ballasted systems.

Both traditional electromagnetic and high frequency electronic fluorescent ballasts utilise 50 - 60 Hz input power. The electromagnetic

ballast merely regulates the 50Hz power and sends it to the lamp. The electronic ballast transforms the input power to a high frequency

(20-40 kHz) before sending it to the lamp. This results in lower lamp and ballast losses and a higher system efficacy - as much as 30%.

ballast terminology

Ballast Power Factor: The ratio of the root mean square (RMS) power (Watts) to the volt-amps (VA) of the ballast. The power factor of the

electrical loads, such as ballasts, on a system determine the overall power of the building electrical system. That measure is an indication

of how efficiently electrical power is being transferred from the source to those building loads. (Note: power factor does not measure how

efficiently the power is being used by the building loads). A high power factor (HPF) rating of a ballast signifies a desirable power factor

equal to or greater than 0.90. A low or “normal” power factor (NPF) rating signifies a power factor less than 0.90 - usually between 0.40

and 0.70. Electric utilities may penalise customers whose overall building load has a low power factor since the lowers and transmissions

efficiency of the utility’s system.

Input Voltage: The design operating voltage of the ballast. Most ballasts are designed to operate at between 120 or 277 volts.

Lamp - Ballast system efficacy: The ratio of lamp light output tp ballast input watts, in units of lumens per watt.

Line Current Amps: The current drawn by the ballast when operating at rated voltage.

Lamp Current Crest Factor (LCCF): The ratio of the peak current to the root means square (RMS) lamp current. The LCCF for lamps operated

at high frequency is equal to the peak current of the modulated wave (50Hz) divided by the RMS lamp current. High current crest

factors reduce lamp life and increase lamp depreciation. Life ratings for lamps are based upon an LCCF of 1.7 or less.

Regulation (of line voltage): The ability of the system light output to adjust for input voltage variations. Generally expressed as a percentage

variation in light output of a lamp for a percentage variation in input voltage.

Volt-Amps: The apparent power of a system. It is equal to RMS of voltage x RMS of current.

trading

33


031 569 3573

info@pureluxtrading.com

www.pureluxtrading.com