Clino Guard

more time for excellent care

Rising costs, staff shortages and an aging society are just three of the

many reasons why medical and nursing care must become more efficient.

Clino Guard from Ackermann, an RFID-based system for networked

safety solutions, makes it possible to meet these market requirements.

Discreet protection due to RFID technology

Clino Guard Radio Frequency IDentification is employed when the safety of

people, facilities and equipment is a top priority. Intelligent transponders allow

reliable, discreet and contactless identification and localization.

The right system for everybody

Clino Guard is available in two versions. With the basic Clino Guard system

(starting from page 18), you can provide safety for smaller buildings or areas at

very little cost. Clino Guard plus (starting from page 6) is the system of choice

for larger projects and if networking with other systems is a requirement.

Safety Productivity Networking


4

Clino Guard in practice –

in hospitals and care facilities


A flexible system with a wide range of options

Protection of people suffering from dementia

A perfect combination of freedom of movement and safety due

to virtual protection zones

Baby protection

Clear identification including an alarm if the transponder is removed

– minimizes the risk of mistaken identity and protects

in a sustained manner

Mobile call initiation

For nurse calls, emergency calls and for staff acknowledgement

of calls

Localization of persons

Rapid localization of persons, supported by video surveillance,

if required

Personal safety

Increased safety while on the move due to movement sensors

and temperature monitoring

Device tracking

Location technology and protection against theft; also available with

movement sensors and tamper alarm to suit different applications

Audit-proof logging

Automatic logging of all call data (location, time, person,

acknowledgement) via connection to the nurse call system

Access surveillance

Effective protection of entrances and exits, elevators, treatment

rooms, outdoor areas, etc.

Cashless payment

Extra comfort for patients or residents

5


6

Clino Guard plus –

networking for extra efficiency

The networking of Clino Guard plus with the nurse call system is a key

feature: a wide range of functions makes it easier and safer to organize

care processes – from the protection of people suffering from dementia

to device tracking. In this way, an integrated solution is created that

combines all of the functions required. It provides practical support for

care processes, including audit-proof recording of all calls and alarms.

Compelling arguments in favor of Clino Guard plus:

• Optimal safety for patients and staff

• Increased quality of life and freedom of movement for residents

• Support for care processes

• Wide range of application:

baby protection, protection of dementia sufferers, device tracking, etc.

• Integration with the nurse call system

• Discreet and effective due to RFID technology

• Clear identification due to unique ID

• Real-time location system

• Options for mobile call forwarding etc.


8

Clino Guard plus –

intelligent system, cleverly integrated

Nurse call server

and other

systems

Central Control unit Station

Functions of Clino Guard plus (exact localization and identification)

Real-time location system

Clino Guard plus essentially consists of three components:

the location system hardware (receiver and transmitter

units), the software and the RFID transponders. Communication

between the transponders and the receiver

units is bidirectional and facilitates localization in real time.

The transmitter units transfer position information to the

transpon ders. The transponders then transmit this infor-

mation and their own unique ID to the receiver unit. The

Clino Guard plus software contains escalation routines

that allow several different alarm scenarios.

Precisely defined protection zones

The transmitter units generate a spherical detection field

inside buildings with a radius of about 5 meters. To cover

larger areas up to 375 m2 , several slave units are simply

added to a master transmitter unit. The receiver units

record the data from transponders in a radius of 25 m, or

up to 250 m in outdoor areas. This facilitates precise protection

of specific areas.

Receiver unit

Transponder functions:

• Deliberate call initiation:

– Movement sensor

– Temperature monitoring

– Alarm if transponder is removed

– Alarm after latency period without movement

• Mobile call initiation

• Vibration as acknowledgement of call initiation or

as call signal

• Continuous monitoring of functions (battery, loss)

intelligent transponders

Transponders

Transmitter unit

Transmitter unit


Nurse call server with

Clino Guard plus software

Clino Call DECTplus

central control unit

Ward Management

Controller

Central Control unit

Schematic networking of Clino Guard plus Corridor data bus

Direct connection

Data network

Synergies with the nurse call system

Clino Guard plus can be connected centrally to the nurse

call system, for example to forward triggered calls and

alarms to the nursing staff in a targeted way, using either

dashboards or mobile devices. The corresponding software

can also integrate additional systems to support the

processes in an optimal way. For example, only certain

persons are allowed access to sensitive areas.

Software supports processes

Clino Guard plus software allows nurses to access all

call information centrally on the PC workstation. Data

from other systems is also displayed or made accessible,

for example video recordings. It can be seen at a glance

where, when and by whom the alarm was triggered. As a

result, the nursing staff can react in a more targeted way,

saving a lot of valuable time.

Clino Guard plus

receiver unit

Dashboard

7 : NBP M > 125

DECT terminal

devices

Station

Clino Guard plus

transmitter unit 1

Clino Guard plus

transmitter unit 2

Master station

9


10

Product overview

Clino Guard plus

790P400

Basic starter package

790P412 License-Update BSP – Online

Basic starter package for a single-door transponder system, consisting of a

transmitter unit and a receiver unit, with the option of upgrading to an „Online

system“. Transmitter unit with permanent LF field with an adjustable range of

up to 5 m (exciter frequency: 9 KHz), field can be extended by using up to 4

„slave“ transmitter units. Individual set-up of transmitter unit ID with the option

of alarm suppression via the integral control input in the transmitter unit, e.g.

via an external door contact. Receiver unit reliably detects patient and staff

transponders (reception frequency: 868 MHz). Alarms are reliably signaled via

the integral relay contact, e.g. for transmission to the nurse call system. Integral

buzzer for acoustic signaling of an alarm locally. Alarm suppression on active

confirmation by a staff transponder (outside the active detection area, radius

depends on building design: max. approx. 30 m), or when the staff transponder

is recognized within the detection area of the transmitter unit. Transponder battery

monitoring with acoustic signal and fitted with LED signal elements for local

status display, and also includes a local reset function. Transmitter and receiver

units can be networked via an RS-485 data bus that can be extended by the

license update „Basic starter package for online system“ (required for each

starter package), with the option of migrating all activities to the „Basic Software

Online System“ via Ethernet-LAN (TCP-IP / RS485 converter required). PSU via

the separate 230 V AC / 12 V DC power supply / UPS combination.

License update for the „basic starter package online system“ with the ability to

transfer all activities to „base-line software system“ via Ethernet LAN. Separate

license update per starter package is necessary. (TCP-IP / RS485-converter

required).


790P401

Locator unit

790P402 Locator unit slave

790P403

Transmitter unit with permanent LF field with an adjustable range of up to 5 m

(exciter frequency: 9 KHz), field can be extended by using up to 4 „slave“ transmitter

units. Individual set-up of transmitter unit ID with the option of alarm suppression

via the integral control input in the transmitter unit, e.g. via an external

door contact. A transponder receives the transmitter unit ID and transmits this

ID to the receiver unit together with its own transponder ID. Transmitter and

receiver units can be networked via an RS-485 data bus, option of using the

„Online System“ to migrate all activities to the „Basic Software Online System“.

Fitted with LED signal elements for local status display, and also includes a

local reset function. PSU via the separate 230 V AC / 12 V DC power supply /

UPS combination (up to 2 units). RS 485 (RJ45 terminals), optional end-of-line

resistor.

Optional „slave“ transmitter unit to extend the coverage (doors / zones) of a

higher-level transmitter unit, connected via the RS485 data bus. With permanent

LF field with an adjustable range of up to 5 m (exciter frequency: 9 kHz),

synchronized with the transmitter unit.

Receiver unit

Receiver unit for reliable detection of patient and staff transponders (reception

frequency: 868 MHz). Alarms are reliably signaled via the integral relay contact,

e.g. for transmission to the nurse call system. Integral buzzer for acoustic

signaling of an alarm locally. Alarm suppression on active confirmation by a

staff transponder (outside the active detection area, radius depends on building

design: max. approx. 30 m), or when the staff transponder is recognized within

the detection area of the associated transmitter unit. Transponder battery monitoring

with acoustic signal and fitted with LED signal elements for local status

display, and also includes a local reset function. Transmitter and receiver units

can be networked via an RS-485 data bus, option of using the „Online System“

to migrate all activities to the „Basic Software Online System“ via Ethernet-LAN

(TCP-IP / RS485 converter required). Fitted with LED signal elements for local

status display, and also includes a local reset function.

11


12

790P404

790P405

790P406

790P407

TCP-IP / RS485 converter

TCP-IP / RS485 converter to connect the transmitter / receiver units and optional

input / output modules (max. 30 components) to the nurse call server for the

Clino Guard plus system via Ethernet-LAN. Fitted with an RJ45 socket for use

with Ethernet-LAN (10 / 100MBit). RS485 data bus wired via the CAT5 junction

box supplied and the associated connecting lead. Fitted with 3 LED signal elements

for local status display. Components and TCP-IP / RS485 converter are

administered via the „Basic Software Online System“.

Input / output module

Interface unit with 16 inputs and 16 outputs to connect external systems to

Clino Guard plus via potential-free contacts. Control of outputs and evaluation

of inputs depends on the configuration of the higher-level „Basic Software

Online System“. Inputs are used in quiescent current or normally open circuit

technology and outputs are used as NC or NO contacts.

Cable for input / output module

Connecting lead for interface unit.

Power supply / UPS 230VAC-12VDC 2A

Device combination consisting of single-phase power supply (12 V DC / 2 A) for

the constant DC supply and as an uninterruptible power supply (Online DC-

UPS) to components of the Clino Guard plus system. Compact construction

using the latest circuit technology with integral battery module (7 Ah), ready for

wall mounting. Fitted with tamper contact and fault message contact in case of

power failure. The device status is shown on an LED display: AC mains power,

power failure (UPS operation). To achieve the maximum bridging period, the

battery must be replaced every 4 years.


790P410

Basic Software Online System

Software module „Basic Software Online System“ for administration and configuration

of the Clino Guard plus. For installation on the Clino System 99plus

nurse call server (minimum requirement: Windows XP Pro) with facilities for setting

up the transmitter / receiver units and optional input / output modules. Allocation

of transponder configuration data (patients, baby, staff, devices, etc.) and dependencies

between different transponders (e.g. mother / baby transponders)

and associated escalation stages. Configuration stored in a system database

for data backup and further use, e.g. on the Clino System 99plus nurse call

server. Administration of all incoming activities and alarms (transponders, inputs)

and execution of the dependent escalation stages. All system components

monitored and all activities saved in online mode. Administrator access rights

required to adapt the ETH-LAN network card (10 / 100) settings to the system

environment of the Clino Guard plus. Full TCP / IP network card support required

for access to the ETH-LAN.

Application software for the following functions:

– Configuration tool

– Allocation of transmitter and receiver units (incl. inputs and outputs)

– Allocation of transponder configuration (name, ID, function)

– Definition of system parameters for Clino Guard plus

– Setting up alarm types (name, type)

– Configuration of input and output modules for control of external systems

– Service functions

– Database management system for configuration data storage

– Simple system management tools for system analysis

– Logging of all system activities

– Set-up of fault monitoring

– Ready for further license updates (video surveillance, graphical user interface

and access control etc.)

Optionally:

– Message transmission to a wireless message system (e.g. personal paging

system - PPS – or telecommunications system - DECT)

– Freely configurable pager addresses for messages from Clino Guard plus

– Definition of the display format for the messages to be transmitted

– Assignment of repeat intervals, acoustic call signals, etc.

13


14

790P411

790P413

IPC-driver for online system

License update for the „Basic Software Online System“ with the option of

migrating all activities to the Clino System 99plus via IPC interface. A license

update is required for each system. An existing System 99plus is required.

ESPA driver for online system

License update for the „Basic Software Online System“ to connect a message

transfer system to Clino Guard plus via ESPA 4.4.4. Option of adapting the

settings to the project- specific requirements of the care facility. Call messages

from the system are transmitted to the connected message transfer system according

to the configuration and displayed by the configured DECT telephones.

Administrator access rights are required to change settings, e.g. to adapt the

serial interface to the system environment.

Application software for the following functions:

– Configuration tool with database management system for data storage

– Serial interface set-up (RS232 / RS422)

– Freely configurable pager addresses

– Allocation of alarm messages to pager addresses

– Assignment of repeat intervals

– Adjustment of acoustic call signals

– Configuration of different escalations for each call type group

– Definition of the display format for the messages to be transmitted

Prerequisites:

– Software module „Basic Software Online System“ Clino Guard plus

Clino System 99plus nurse call server with free serial interface

– Serial connecting lead


790P420

790P421

790P422

790P423

Transponder for the „dementia“ patient

Transponder for patients with dementia, to be worn on the wrist. Transponder

is actuated if it enters the permanent LF field of a transmitter unit. The transponder

processes the transmitter unit ID and transmits this ID to the receiver

unit together with its own transponder ID. The battery status is also transmitted.

Transmission range up to 25 m, dependent on ambient conditions.

Transponder for the patient „alarm“

As part no. 790P420, but also has an alarm button. Patient can activate an

alarm, even on the move. Alarm is acknowledged via the integral LED.

Transponder for baby

As part no. 790P420, but specially designed for monitoring a baby. Use in conjunction

with an associated mother transponder for alarm suppression.

Transponder for mother

As part no. 790P420, but specially designed to be worn by a mother whose

baby is wearing the baby transponder. The alarm can only be suppressed if the

mother transponder which has been assigned to a baby transponder enters the

permanent LF field of a transmitter unit.

15


16

790P424

790P425

Transponder for care giver

As part no. 790P420, but specially designed to be worn by a nurse. Also fitted

with a confirmation button. The alarm can be suppressed if a patient transponder

enters the permanent LF field of a transmitter unit in conjunction with the

staff transponder. The confirmation button also enables the nurse to suppress

an alarm even outside the LF field of the receiver unit by setting the receiver unit

to inactive. Button confirmation is acknowledged via the integral LED.

Transponder for surveillance

The calibration transponder is used during commissioning of the Clino Guard

plus system, specifically to detect and establish the radio range of the transmitter

units. The LED integrated into the transponder lights up when the wearer

enters the LF field. The LED goes out when the wearer leaves the radio range

of the transmitter unit. An acoustic acknowledgement in the receiver unit is

triggered by pressing a button on the calibration transponder. The transponder

can be used during commissioning of „Single-door transponder systems“ for

assignment of transmitter and receiver units.


790P426

790P427

790P428

790P429

Bracelet (velcro) for transponder

Bracelet to enable a transponder to be worn on the wrist. Can be reused many

times thanks to the easy-to-open velcro fastener, specifically designed to attach

the transponder to the wrist.

Bracelet (rubber) for transponder

Rubberized bracelet to enable a transponder to be worn on the wrist. Bracelet

closure cannot be opened, to prevent deliberate removal. The bracelet can only

be removed by destroying it.

Bracelets for transponder „dementia“

Bracelet to enable a transponder to be worn on the wrist. Bracelet closure

cannot be opened, to prevent deliberate removal. The bracelet can only be

removed by destroying it.

Accessories (10 caps plus sealings)

Set of spare parts for white transponders, consisting of 10 covers with seals

and a tool to open the transponder cover.

17


18

Clino Guard

easy installation,

reliable protection

Clino Guard combines safety and freedom of movement, especially for

people suffering from dementia. The transmitter / receiver units can be

installed in just about any place to provide unobtrusive protection: near

the door area, indoors or outdoors. The detection area is between

3.5 and 6 m; this can be extended using additional aerials and ground

contacts, if needed.

Intelligent and reliable detection

The use of different resting and operating frequencies (125 kHz / 868 MHz) and

three-dimensional aerials guarantees reliable detection and data transmission.

The system also recognizes automatically when a patient is accompanied by a

nurse and does not trigger an alarm.

Compelling arguments in favor of Clino Guard:

• Reliable safety for patients and staff

• Discretion due to virtual protection zones

• Lower level of supervision required

• Increased quality of life and freedom of movement

• System is easy to install

• Robust, discreet transponders for patients

• Transponders with call cancellation for staff

important notice: the latest generation of Clino Guard systems is

not compatible with previous versions.


20

Product overview

Clino Guard

790P100

790P137

790P033

790P103

790P031

Locator / receiver unit

Active transponder system with adjustable range up to 6 m radius. Consisting

of an antenna unit (868 MHz operating frequency, 125 kHz stand-by frequency),

an evaluation unit with relay contacts (changeover), integrated alarm signaling

device, and 230 V power supply (integrated). Expandable with a relay card

for zone identification and an additional external antenna (if necessary also via

reproducer).

Relay card – Locator / receiver unit

The active transponder system can be expanded by the relay card for identification

of several persons or groups. Up to five persons or groups can be

differentiated. For example, the outputs can be used for connection to the

nurse call system in order to generate dedicated alarms in the respective station.

Additionally, a reader-monitoring notification or also a battery status onward

transmission can be generated. The allocation of a patient transponder occurs

directly via the relay card.

Additional antenna – compact

Additional antenna to adjust the detection range to special architectural requirements

by up to 3.5 m.

Locator / receiver unit „IP64“

As 790P100, but in external housing with IP 64 moisture protection.

Auxiliary LF antenna (optional)

Supplement of transmitter / receiver unit - long distance. This auxiliary LF

antenna for long distance is to be used for ranges exceeding 5.5 m. Especially

suitable to adjust the receiver area to special structural demands such as wide

entrance doors, for example.


790P120

790P121

790P122

790P123

790P124

Patient transponder pendant

Patient transponder with three-dimensional antenna and battery monitoring.

Patient transponder watch dummy

Patient transponder with three-dimensional antenna and battery monitoring.

The bracelet can only be opened with a magnetic key held by the care

personnel.

Patient transponder watch

Patient transponder with three-dimensional antenna and battery monitoring.

The bracelet can only be opened with a magnetic key held by the care

personnel.

Patient transponder alarm

Transponder bracelet for the patient to the emergency release outside the active

sensing area of a transceiver, radius dependent of the building condition:

a maximum of about 30 m. Leather bracelet with classic buckle.

Transponder for care giver

Personal transponders with one-dimensional-looking antenna and battery monitoring,

call restriction and to call canceling. This transponder is not suitable as

patient transponder.

21


22

790P050

790P053

790P054

790P051

790P052

Leather case

Leather case with magnetic fastener (white button) for patient transponder

(790P120) to be attached to clothing (e.g. to the belt) including

accessories.

Magnetic key

Magnetic key integrated in a bag to open the magnetic fasteners (white button

and bracelet). For nursing personnel only.

Spare bracelet with fastener

Spare bracelet for bracelet transponder (Part No. 790P121).

Spare fastener

Complete additional magnetic fastener (white button)

Spare bracelet with fastener

Spare bracelet for wrist watch transponder (Part No. 790P11, 790P122).


Comparison of systems

Applications Clino Guard plus Clino Guard

Protection of people with dementia • •

Baby protection •

Access surveillance • •

Direction detection •

Device tracking •

Person locating system •

Call forwarding (also as SMS etc.) • limited

Cashless payment •

Functions

Localization in real-time •

Identification unique only groups

Mobile call initiation / call cancellation

(staff)

• •

Movement sensor* •

Temperature monitoring* •

Monitoring of transponder batteries • •

Audit-proof recording (call type, location,

time, person, additional information)

• only call type and time

Alarm caused by sensor removal* •

Tamper alarm* (device transponder) •

Vibration alarm* (call acknowledgement

or nurse call)


*Transponder types on request

Installation

Networking with nurse call system •

IPC interface to Ackermann •

Commissioning by Ackermann /

partners

• optional

Quick installation •

note: the current generation of Clino Guard systems is not compatible with previous

versions! Components and replacement parts for previous versions are still available –

please feel free to contact us.

this overview will make it easy for you

to select the right system. if you have

any technical questions, please contact

ackermann – see reverse for contact

information.

23


Your specialists:

Novar GmbH a Honeywell Company

Dieselstraße 2

41469 Neuss, Germany

Tel.: + 49 2137-17-0 (Administration)

Tel.: + 49 2137-17-600 (Customer Service)

Fax: + 49 2137-17-286

Internet: www.ackermann-clino.com

E-Mail: info@ackermann-clino.com

Honeywell Life Safety Austria GmbH

Lemböckgasse 49

1230 Vienna, Austria

Tel.: +43 1 600 6030

Fax: +43 1 600 6030-900

Internet: www.hls-austria.at

E-Mail: hls-austria@honeywell.com

November 2011

Subject to change without notice.

© 2011 Honeywell International Inc.

More magazines by this user
Similar magazines