23.12.2012 Views

Catalogue

Catalogue

Catalogue

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

50<br />

3. e)<br />

Gradual DC brake<br />

(MTFPC, DPFPC, MMFPC)<br />

PRODUCTION STANDARDS<br />

Mounting arrangement IMB3<br />

Terminal box position On top (BS)<br />

Rated voltage MT 230/400V 50 Hz (Pn ≤ 3 kW)<br />

400/690V 50 Hz (Pn > 3 kW)<br />

DP 400V 50 Hz<br />

MM 230V 50 Hz<br />

Brake rated voltage (separate connection) 230V (400 V for Pn > 3 kW)<br />

Voltage rectifier Half- or full-ware type<br />

Protection rating IP54<br />

Bearings 2 RS<br />

Winding insulation Class F<br />

Terminal box type 2 aluminium components (box + cover)<br />

End-shields assembly Bosses and bolts<br />

Paint finish BLUE RAL 5010<br />

Fan cover Galvanized steel sheet<br />

Duty S1<br />

This type of brake is designed for machinery where<br />

gradual but not necessarily precision braking is<br />

required. Thanks to the single friction surface, FPC<br />

brake provides noiseless controlled stopping with<br />

low braking torque to prevent damage to machinery<br />

and operator alike.<br />

The brake friction is applied by the action of a set<br />

of springs that push the armature plate against the<br />

internal surface of the cast iron cooling fan. When<br />

the coil is energized through a rectifier, the brake is<br />

released.<br />

The brakes are supplied adjusted to the nominal<br />

values air gap and must be reset when wear occurs.<br />

The rate brake wear depends on operating conditions.<br />

To reset air gap it is necessary to tighten up the<br />

adjustment screw till reaching the rated value listed<br />

in the table below.<br />

The access to the adjustment screw is possible with<br />

no need for the fan cover to be removed.<br />

REMARK: when placing an enquiry, following<br />

information are required: application details, AC brake<br />

voltage supply, load inertia, duty cycle with number<br />

of starts/stops per hour, type of supply connection<br />

(on terminal block or separate).<br />

Special rectifier are available to provide EMC filtering<br />

and/or to reduce time of brake operation.<br />

Size<br />

Braking<br />

torque<br />

(Nm)<br />

Power<br />

(W)<br />

FPC End-shield<br />

Enganging<br />

time<br />

(ms)<br />

Release<br />

time<br />

(ms)<br />

Air gap<br />

(mm)<br />

M63 2,5 15 20 40 0,2<br />

M71 4 15 15 100 0,2<br />

M80 9 20 15 120 0,2<br />

M90 9,5 20 15 120 0,25<br />

M100 12 30 10 200 0,25<br />

M112 12,5 30 10 200 0,25<br />

M132 23 30 10 200 0,3<br />

M160 23 60 13 215 0,3<br />

Key<br />

Shaft<br />

Spring<br />

Air gap<br />

Brake coil<br />

Mobile anchor<br />

Friction pad<br />

Nuyloc nut<br />

Adjustment<br />

screw<br />

Washer<br />

Cooling fan (cast iron)

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!