25.05.2021 Views

Thermex Stainless Steel Tanks 3.0

Transform your PDFs into Flipbooks and boost your revenue!

Leverage SEO-optimized Flipbooks, powerful backlinks, and multimedia content to professionally showcase your products and significantly increase your reach.

EDITION <strong>3.0</strong><br />

automaticheating.com.au<br />

<strong>Thermex</strong> <strong>Stainless</strong> <strong>Steel</strong><br />

Hot Water <strong>Tanks</strong>


<strong>Thermex</strong> - <strong>Stainless</strong> <strong>Steel</strong> Hot Water <strong>Tanks</strong><br />

2<br />

Automatic Heating


<strong>Thermex</strong> - <strong>Stainless</strong> <strong>Steel</strong> Hot Water <strong>Tanks</strong><br />

Duplex 2205 <strong>Stainless</strong> <strong>Steel</strong><br />

Hot Water <strong>Tanks</strong><br />

170L - 5000L<br />

Certificate 23261<br />

If you are installing <strong>Thermex</strong>, you can be confident you are installing quality.<br />

Manufactured from high specification Duplex 2205<br />

<strong>Stainless</strong> <strong>Steel</strong>, our <strong>Thermex</strong> range is designed<br />

to resist all forms of corrosion, including crevice<br />

and stress corrosion. Its high mechanical strength<br />

promises durability, while automated welding<br />

procedures, post weld pickling and passivating<br />

treatment guarantee each individual weld is as strong<br />

as its parent metal. Our <strong>Thermex</strong> <strong>Stainless</strong> <strong>Steel</strong> Hot<br />

Water <strong>Tanks</strong> are pressure tested to a full 12 bar - four<br />

times their normal working pressure - and injected<br />

with 50mm of our HCFC free Polyurethane insulation<br />

to achieve astonishingly low levels of heat loss, which<br />

maximises energy efficiency for your customers.<br />

<strong>Thermex</strong> <strong>Stainless</strong> <strong>Steel</strong> Hot Water <strong>Tanks</strong> provide a<br />

reliable and cost-effective solution to the domestic<br />

hot water heating and storage requirements of<br />

commercial & domestic premises, particularly hotels<br />

and apartments. These tanks are high quality, long<br />

service life stainless steel vessels for projects that<br />

have large volume heating/domestic hot water/solar<br />

HVAC water systems.<br />

Available with twin coils, fully insulated and<br />

Watermark approved, <strong>Thermex</strong> <strong>Stainless</strong> <strong>Steel</strong> Hot<br />

Water <strong>Tanks</strong> provide quick recovery and are suited to<br />

high demand usage. Key supply advantages include<br />

large stock holdings in a range of sizes, including<br />

compact units designed to fit through standard<br />

doorways.<br />

<strong>Thermex</strong> range of tanks use high recovery smooth<br />

tube coils for optimal performance. No other coil<br />

type on the market today offers the same transfer<br />

rate as smooth stainless tube.<br />

Product Quick Check<br />

Type<br />

Material<br />

Range<br />

<strong>Stainless</strong> <strong>Steel</strong> Hot Water <strong>Tanks</strong><br />

Duplex 2205 <strong>Stainless</strong> <strong>Steel</strong><br />

170 - 5000L<br />

Suitable Heat Sources Gas, Oil, Wood, Pellet Boiler,<br />

Solar, Electric, Photovoltaic<br />

Available with Coils<br />

Yes<br />

Outdoor Suitable Yes (up to 1000L)<br />

Max Pressure<br />

Low Nox<br />

Building J Code<br />

2019 compliant<br />

700kPa<br />

Yes<br />

Yes<br />

Automatic Heating 3


<strong>Thermex</strong> - <strong>Stainless</strong> <strong>Steel</strong> Hot Water <strong>Tanks</strong><br />

Features<br />

• Superior Quality Duplex 2205 <strong>Stainless</strong> <strong>Steel</strong><br />

• Smooth tube coil construction for durability and<br />

performance<br />

• Butt Welded process used on all joins<br />

• Large coil surface areas<br />

• No sacrificial anodes required<br />

• 100% pickled and passivated<br />

• Thick insulation polyurethane foam layer<br />

λ = 0,022 W/mK<br />

• Optional backup electric heating element<br />

Hot water outlet<br />

Metal outer casing<br />

T & P Valve<br />

Thermometer<br />

Top Heat Exchanger Coil<br />

Temperature Sensor<br />

Top Heat Exchanger Coil<br />

Bottom Heat Exchanger Coil<br />

Duplex <strong>Stainless</strong><br />

<strong>Steel</strong> 316L Heat<br />

Exchanger Coil<br />

Secondary Return<br />

Heating Element Connection<br />

/ Inspection Port<br />

Temperature Sensor<br />

Cold water inlet<br />

Pickled and<br />

passivated<br />

Bottom Heat Exchanger Coil<br />

High Density rigid polyurethane<br />

foam, 50mm thick<br />

4<br />

Automatic Heating


<strong>Thermex</strong> - <strong>Stainless</strong> <strong>Steel</strong> Hot Water <strong>Tanks</strong><br />

Direct<br />

• Material - <strong>Stainless</strong> <strong>Steel</strong> 2205<br />

• Insulation: 170-1000L<br />

- 50mm Rigid Polyurethane<br />

- 1500-5000L Expanded Foam Jacket<br />

• Outer Casing - Painted Galvanised Carbon <strong>Steel</strong>*<br />

• Tank working Pressure - 700kPa<br />

• Temperature & Pressure Relief Valve<br />

rated 99°C / 700kPa<br />

Specifications<br />

170 - 1000L<br />

Model No. Capacity (litres) External Dia. (Ø) mm Total Height (H) mm Weight (Empty) kg<br />

TSSI170 170 550 1230 60<br />

TSSI200 200 550 1410 60<br />

TSSI300 300 620 1600 90<br />

TSSI400 400 710 1550 100<br />

TSSI500 500 710 1900 120<br />

TSSI750 750 920 1800 160<br />

TSSI1000 1000 920 2200 240<br />

170L - 1000L<br />

1500 - 5000L<br />

TSSI1500 1500 1150 2400 270<br />

TSSI2000 2000 1300 2400 340<br />

TSSI2500 2500 1400 2800 420<br />

TSSU3500 3500 1470 3300 655<br />

TSSU4000 4000 1470 3800 850<br />

TSSU4500 4500 1590 3300 885<br />

TSSU5000 5000 1590 3800 1140<br />

1500L - 5000L<br />

HOT OUTLET<br />

ISOLATOR<br />

SWITCH<br />

OFF-PEAK<br />

CONTROLLER<br />

COLD INLET<br />

Automatic Heating 5


<strong>Thermex</strong> - <strong>Stainless</strong> <strong>Steel</strong> Hot Water <strong>Tanks</strong><br />

Indirect 2 Coils<br />

• Material - <strong>Stainless</strong> <strong>Steel</strong> 2205<br />

• Coil Material - AISI 316L<br />

• Insulation: 170-1000L<br />

- 50mm Rigid Polyurethane<br />

- 1500-5000L Expanded Foam Jacket<br />

• Outer Casing - Painted Galvanised Carbon <strong>Steel</strong>*<br />

• Coil Working Pressure - 600kPa<br />

• Tank working Pressure - 700kPa<br />

• Temperature & Pressure Relief Valve<br />

rated 99°C / 700kPa<br />

Specification<br />

170 - 1000L<br />

Model No.<br />

Capacity<br />

(Litres)<br />

Coil kW<br />

Top/<br />

Bottom<br />

Coil Flow<br />

Rate L/s<br />

Top/Bottom<br />

Coil Pressure<br />

Drop (kPa)<br />

Top/Bottom<br />

First hour delivery<br />

Capacity (L)<br />

(2 coils in parallel)<br />

External Dia.<br />

(Ø) mm<br />

Total<br />

Height<br />

(H) mm<br />

TSSI2C170 170 20 / 22 0.24 / 0.26 2.98 / 3.33 1959 550 1230 60<br />

TSSI2C200 200 22 / 32 0.26 / 0.38 2.98 / 15.71 2502 550 1410 60<br />

TSSI2C300 300 24 / 36 0.29 / 0.43 9.6 / 19.5 2850 620 1600 90<br />

TSSI2C400 400 24 / 48 0.29 / 0.57 1.59 / 10.53 3456 710 1550 100<br />

TSSI2C500 500 36 / 60 0.43 / 0.72 4.5 / 19.13 4578 710 1900 120<br />

TSSI2C750 750 87 / 120 1.04 / 1.43 28.95 / 47.7 9576 920 1800 160<br />

Weight<br />

(Empty)<br />

kg<br />

TSSI2C1000 1000 87 / 160 1.04 / 1.91 9.23 / 55.67 11521 920 2200 240<br />

170L - 1000L<br />

1500 - 5000L<br />

TSSU2C1500 1500 120 / 180 1.43 / 2.15 27.03 / 50.9 14250 1150 2400 270<br />

TSSU2C2000 2000 160 / 200 1.91 / 2.39 18.46 / 35.18 17280 1300 2400 340<br />

TSSU2C2500 2500 180 / 240 2.15 / 2.87 30.16 / 78.54 20310 1400 2800 420<br />

TSSU2C3500 3500 185 / 250 2.21 / 2.99 14 / 29.5 10632 1470 3300 655<br />

TSSU2C4000 4000 220 / 285 2.63 / 3.4 22.5 / 36 12286 1470 3800 850<br />

TSSU2C4500 4500 220 / 320 2.63 / 3.82 22.5 / 43 13338 1590 3300 885<br />

TSSU2C5000 5000 220 / 355 2.63 / 4.24 22.5 / 52 14390 1590 3800 1140<br />

Note: Flow rates in the coil are based on 20° ΔT (Inlet/Outlet Temperature = 80/60°C)<br />

1500L - 5000L<br />

SENSOR CIRCUIT<br />

HOT OUTLET<br />

SOLAR<br />

CONTROLLER<br />

SOLAR<br />

PUMPING<br />

STATION<br />

EXPANSION<br />

VESSEL<br />

PRESSURE<br />

RELIEF<br />

SEALED SYSTEM<br />

BOILER<br />

CENTRAL HEATING SUPPLIED BY BOILER<br />

COLD INLET<br />

6<br />

Automatic Heating


<strong>Thermex</strong> - <strong>Stainless</strong> <strong>Steel</strong> Hot Water <strong>Tanks</strong><br />

Dimensional Data<br />

Ø<br />

HOT WATER OUTLET<br />

Ø<br />

T&P RELIEF<br />

VALVE<br />

HOT WATER OUTLET<br />

THERMOMETER<br />

BOILER<br />

FLOW<br />

MANOMETER<br />

T&P RELIEF<br />

VALVE<br />

THERMOMETER<br />

IMMERSION<br />

HEATER<br />

SECONDARY<br />

RETURN<br />

Ø<br />

HOT WATER OUTLET<br />

BOILER<br />

FLOW<br />

SENSOR<br />

BOILER<br />

RETURN<br />

SOLAR<br />

FLOW<br />

SENSOR<br />

H<br />

T&P RELIEF<br />

VALVE<br />

IMMERSION<br />

HEATER<br />

SECONDARY<br />

RETURN<br />

COLD WATER<br />

INLET<br />

BOILER FLOW<br />

THEROMETER<br />

SENSOR<br />

BOILER<br />

RETURN<br />

SOLAR<br />

FLOW<br />

SENSOR<br />

SOLAR<br />

RETURN<br />

H<br />

SENSOR<br />

BOILER<br />

RETURN<br />

SOLAR<br />

FLOW<br />

SENSOR<br />

SOLAR<br />

RETURN<br />

IMMERSION HEATER<br />

INSPECTION<br />

SECONDARY<br />

RETURN<br />

COLD WATER<br />

INLET<br />

H<br />

COLD WATER<br />

INLET<br />

SOLAR<br />

RETURN<br />

DRAIN<br />

DRAIN<br />

170L - 500L 750L - 1000L 1500L - 5000L<br />

Drawing represented without thermal insulation<br />

Note: Immersion socket allows for installation of electric element<br />

(allow for 100mm insulation)<br />

Connections Note: All connections are female<br />

Model<br />

Cold<br />

Water<br />

Inlet<br />

Hot<br />

Water<br />

Outlet<br />

Secondary<br />

Return<br />

Primary<br />

Flow<br />

Top Coil<br />

Primary<br />

Return<br />

Bottom Coil<br />

Primary<br />

Flow<br />

Primary<br />

Return<br />

Sensor Immersion T&P Valve Drain<br />

170 - 300L 20NB 20NB 20NB 20NB 20NB 20NB 20NB 15NB 20NB 20NB -<br />

400 - 500L 25NB 25NB 20NB 25NB 25NB 25NB 25NB 15NB 25NB 20NB -<br />

750L 32NB 32NB 25NB 25NB 25NB 25NB 25NB 15NB 25NB 2 x 20NB 25NB<br />

1000 - 1500L 40NB 40NB 25NB 32NB 32NB 32NB 32NB 15NB 32NB 2 x 20NB 25NB<br />

2000 - 2500L 50NB 50NB 25NB 40NB 40NB 40NB 40NB 15NB 40NB 3 x 20NB 25NB<br />

3500L 50NB 50NB 25NB 40NB 40NB 40NB 40NB 15NB 40NB 3 x 20NB 25NB<br />

4000 - 5000L 80NB 80NB 25NB 40NB 40NB 40NB 40NB 15NB 40NB 4 x 20NB 25NB<br />

Automatic Heating 7


<strong>Thermex</strong> - <strong>Stainless</strong> <strong>Steel</strong> Hot Water <strong>Tanks</strong><br />

Immersion Elements<br />

• As supplementary heating device<br />

• Connection 1 ½”<br />

• Inbuilt thermostat<br />

Single Phase<br />

Part No. Output kW Voltage V Max temp ºC Tank Size<br />

TIHE2KW 2 240/1 PH 70 170L-500L<br />

TIHE3KW 3 240/1 PH 70 170L-500L<br />

3 Phase<br />

Part No. Output kW Voltage V Max temp ºC Tank Size<br />

TIHE6KW 6 400/3 PH 85 750L-1000L<br />

TIHE10KW 10 400/3 PH 85 750L-1000L<br />

8<br />

Automatic Heating


<strong>Thermex</strong> - <strong>Stainless</strong> <strong>Steel</strong> Hot Water <strong>Tanks</strong><br />

Installation Examples<br />

P & I Diagram - Meridian 2 x 120kW Condensing Water Heaters C/W 1000L <strong>Thermex</strong> SS <strong>Tanks</strong><br />

1000L <strong>Thermex</strong><br />

S. S. Tank<br />

Meridian 120<br />

Heater No. 1<br />

Meridian 120<br />

Heater No. 2<br />

Supply<br />

Cold<br />

Water<br />

Fill<br />

Flange Connection<br />

C/W Spacer Piece<br />

Cold Water Supply<br />

Expansion<br />

Tank 35L<br />

P & I Diagram<br />

Meridian 100kW Condensing Water Heater C/W 2 x 500L <strong>Thermex</strong> SS <strong>Tanks</strong><br />

DHW Supply<br />

DHW Supply<br />

Meridian 100<br />

500L<br />

<strong>Thermex</strong> S.S. Tank<br />

Secondary Return<br />

Secondary<br />

Return<br />

Cold<br />

Water Fill<br />

240V 10A<br />

GPO<br />

Scorpion SPA32/80<br />

Gas<br />

DHW Supply<br />

500L<br />

<strong>Thermex</strong> S.S. Tank<br />

Cold Fill<br />

FWMA015<br />

Expansion<br />

Tank 35 L<br />

Secondary Return<br />

Automatic Heating 9


<strong>Thermex</strong> - <strong>Stainless</strong> <strong>Steel</strong> Hot Water <strong>Tanks</strong><br />

Case Studies<br />

10<br />

Automatic Heating


<strong>Thermex</strong> - <strong>Stainless</strong> <strong>Steel</strong> Hot Water <strong>Tanks</strong><br />

Prefab Packages for Fast Installation or Rental<br />

Custom hot water heating system packages are available mounted on prefabricated skid<br />

frames for fast installation or for rental where a temporary system is required.<br />

Automatic Heating 11


Automatic Heating Global Pty Ltd<br />

T. +613 8352 7000<br />

E. sales@automaticheating.com.au<br />

67 Gateway Boulevard, Epping VIC 3076<br />

P.O. Box 35a Epping VIC 3076 Australia<br />

W. automaticheating.com.au 18769 210525