25.05.2021 Views

Thermex Stainless Steel Tanks 3.0

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

EDITION <strong>3.0</strong><br />

automaticheating.com.au<br />

<strong>Thermex</strong> <strong>Stainless</strong> <strong>Steel</strong><br />

Hot Water <strong>Tanks</strong>


<strong>Thermex</strong> - <strong>Stainless</strong> <strong>Steel</strong> Hot Water <strong>Tanks</strong><br />

2<br />

Automatic Heating


<strong>Thermex</strong> - <strong>Stainless</strong> <strong>Steel</strong> Hot Water <strong>Tanks</strong><br />

Duplex 2205 <strong>Stainless</strong> <strong>Steel</strong><br />

Hot Water <strong>Tanks</strong><br />

170L - 5000L<br />

Certificate 23261<br />

If you are installing <strong>Thermex</strong>, you can be confident you are installing quality.<br />

Manufactured from high specification Duplex 2205<br />

<strong>Stainless</strong> <strong>Steel</strong>, our <strong>Thermex</strong> range is designed<br />

to resist all forms of corrosion, including crevice<br />

and stress corrosion. Its high mechanical strength<br />

promises durability, while automated welding<br />

procedures, post weld pickling and passivating<br />

treatment guarantee each individual weld is as strong<br />

as its parent metal. Our <strong>Thermex</strong> <strong>Stainless</strong> <strong>Steel</strong> Hot<br />

Water <strong>Tanks</strong> are pressure tested to a full 12 bar - four<br />

times their normal working pressure - and injected<br />

with 50mm of our HCFC free Polyurethane insulation<br />

to achieve astonishingly low levels of heat loss, which<br />

maximises energy efficiency for your customers.<br />

<strong>Thermex</strong> <strong>Stainless</strong> <strong>Steel</strong> Hot Water <strong>Tanks</strong> provide a<br />

reliable and cost-effective solution to the domestic<br />

hot water heating and storage requirements of<br />

commercial & domestic premises, particularly hotels<br />

and apartments. These tanks are high quality, long<br />

service life stainless steel vessels for projects that<br />

have large volume heating/domestic hot water/solar<br />

HVAC water systems.<br />

Available with twin coils, fully insulated and<br />

Watermark approved, <strong>Thermex</strong> <strong>Stainless</strong> <strong>Steel</strong> Hot<br />

Water <strong>Tanks</strong> provide quick recovery and are suited to<br />

high demand usage. Key supply advantages include<br />

large stock holdings in a range of sizes, including<br />

compact units designed to fit through standard<br />

doorways.<br />

<strong>Thermex</strong> range of tanks use high recovery smooth<br />

tube coils for optimal performance. No other coil<br />

type on the market today offers the same transfer<br />

rate as smooth stainless tube.<br />

Product Quick Check<br />

Type<br />

Material<br />

Range<br />

<strong>Stainless</strong> <strong>Steel</strong> Hot Water <strong>Tanks</strong><br />

Duplex 2205 <strong>Stainless</strong> <strong>Steel</strong><br />

170 - 5000L<br />

Suitable Heat Sources Gas, Oil, Wood, Pellet Boiler,<br />

Solar, Electric, Photovoltaic<br />

Available with Coils<br />

Yes<br />

Outdoor Suitable Yes (up to 1000L)<br />

Max Pressure<br />

Low Nox<br />

Building J Code<br />

2019 compliant<br />

700kPa<br />

Yes<br />

Yes<br />

Automatic Heating 3


<strong>Thermex</strong> - <strong>Stainless</strong> <strong>Steel</strong> Hot Water <strong>Tanks</strong><br />

Features<br />

• Superior Quality Duplex 2205 <strong>Stainless</strong> <strong>Steel</strong><br />

• Smooth tube coil construction for durability and<br />

performance<br />

• Butt Welded process used on all joins<br />

• Large coil surface areas<br />

• No sacrificial anodes required<br />

• 100% pickled and passivated<br />

• Thick insulation polyurethane foam layer<br />

λ = 0,022 W/mK<br />

• Optional backup electric heating element<br />

Hot water outlet<br />

Metal outer casing<br />

T & P Valve<br />

Thermometer<br />

Top Heat Exchanger Coil<br />

Temperature Sensor<br />

Top Heat Exchanger Coil<br />

Bottom Heat Exchanger Coil<br />

Duplex <strong>Stainless</strong><br />

<strong>Steel</strong> 316L Heat<br />

Exchanger Coil<br />

Secondary Return<br />

Heating Element Connection<br />

/ Inspection Port<br />

Temperature Sensor<br />

Cold water inlet<br />

Pickled and<br />

passivated<br />

Bottom Heat Exchanger Coil<br />

High Density rigid polyurethane<br />

foam, 50mm thick<br />

4<br />

Automatic Heating


<strong>Thermex</strong> - <strong>Stainless</strong> <strong>Steel</strong> Hot Water <strong>Tanks</strong><br />

Direct<br />

• Material - <strong>Stainless</strong> <strong>Steel</strong> 2205<br />

• Insulation: 170-1000L<br />

- 50mm Rigid Polyurethane<br />

- 1500-5000L Expanded Foam Jacket<br />

• Outer Casing - Painted Galvanised Carbon <strong>Steel</strong>*<br />

• Tank working Pressure - 700kPa<br />

• Temperature & Pressure Relief Valve<br />

rated 99°C / 700kPa<br />

Specifications<br />

170 - 1000L<br />

Model No. Capacity (litres) External Dia. (Ø) mm Total Height (H) mm Weight (Empty) kg<br />

TSSI170 170 550 1230 60<br />

TSSI200 200 550 1410 60<br />

TSSI300 300 620 1600 90<br />

TSSI400 400 710 1550 100<br />

TSSI500 500 710 1900 120<br />

TSSI750 750 920 1800 160<br />

TSSI1000 1000 920 2200 240<br />

170L - 1000L<br />

1500 - 5000L<br />

TSSI1500 1500 1150 2400 270<br />

TSSI2000 2000 1300 2400 340<br />

TSSI2500 2500 1400 2800 420<br />

TSSU3500 3500 1470 3300 655<br />

TSSU4000 4000 1470 3800 850<br />

TSSU4500 4500 1590 3300 885<br />

TSSU5000 5000 1590 3800 1140<br />

1500L - 5000L<br />

HOT OUTLET<br />

ISOLATOR<br />

SWITCH<br />

OFF-PEAK<br />

CONTROLLER<br />

COLD INLET<br />

Automatic Heating 5


<strong>Thermex</strong> - <strong>Stainless</strong> <strong>Steel</strong> Hot Water <strong>Tanks</strong><br />

Indirect 2 Coils<br />

• Material - <strong>Stainless</strong> <strong>Steel</strong> 2205<br />

• Coil Material - AISI 316L<br />

• Insulation: 170-1000L<br />

- 50mm Rigid Polyurethane<br />

- 1500-5000L Expanded Foam Jacket<br />

• Outer Casing - Painted Galvanised Carbon <strong>Steel</strong>*<br />

• Coil Working Pressure - 600kPa<br />

• Tank working Pressure - 700kPa<br />

• Temperature & Pressure Relief Valve<br />

rated 99°C / 700kPa<br />

Specification<br />

170 - 1000L<br />

Model No.<br />

Capacity<br />

(Litres)<br />

Coil kW<br />

Top/<br />

Bottom<br />

Coil Flow<br />

Rate L/s<br />

Top/Bottom<br />

Coil Pressure<br />

Drop (kPa)<br />

Top/Bottom<br />

First hour delivery<br />

Capacity (L)<br />

(2 coils in parallel)<br />

External Dia.<br />

(Ø) mm<br />

Total<br />

Height<br />

(H) mm<br />

TSSI2C170 170 20 / 22 0.24 / 0.26 2.98 / 3.33 1959 550 1230 60<br />

TSSI2C200 200 22 / 32 0.26 / 0.38 2.98 / 15.71 2502 550 1410 60<br />

TSSI2C300 300 24 / 36 0.29 / 0.43 9.6 / 19.5 2850 620 1600 90<br />

TSSI2C400 400 24 / 48 0.29 / 0.57 1.59 / 10.53 3456 710 1550 100<br />

TSSI2C500 500 36 / 60 0.43 / 0.72 4.5 / 19.13 4578 710 1900 120<br />

TSSI2C750 750 87 / 120 1.04 / 1.43 28.95 / 47.7 9576 920 1800 160<br />

Weight<br />

(Empty)<br />

kg<br />

TSSI2C1000 1000 87 / 160 1.04 / 1.91 9.23 / 55.67 11521 920 2200 240<br />

170L - 1000L<br />

1500 - 5000L<br />

TSSU2C1500 1500 120 / 180 1.43 / 2.15 27.03 / 50.9 14250 1150 2400 270<br />

TSSU2C2000 2000 160 / 200 1.91 / 2.39 18.46 / 35.18 17280 1300 2400 340<br />

TSSU2C2500 2500 180 / 240 2.15 / 2.87 30.16 / 78.54 20310 1400 2800 420<br />

TSSU2C3500 3500 185 / 250 2.21 / 2.99 14 / 29.5 10632 1470 3300 655<br />

TSSU2C4000 4000 220 / 285 2.63 / 3.4 22.5 / 36 12286 1470 3800 850<br />

TSSU2C4500 4500 220 / 320 2.63 / 3.82 22.5 / 43 13338 1590 3300 885<br />

TSSU2C5000 5000 220 / 355 2.63 / 4.24 22.5 / 52 14390 1590 3800 1140<br />

Note: Flow rates in the coil are based on 20° ΔT (Inlet/Outlet Temperature = 80/60°C)<br />

1500L - 5000L<br />

SENSOR CIRCUIT<br />

HOT OUTLET<br />

SOLAR<br />

CONTROLLER<br />

SOLAR<br />

PUMPING<br />

STATION<br />

EXPANSION<br />

VESSEL<br />

PRESSURE<br />

RELIEF<br />

SEALED SYSTEM<br />

BOILER<br />

CENTRAL HEATING SUPPLIED BY BOILER<br />

COLD INLET<br />

6<br />

Automatic Heating


<strong>Thermex</strong> - <strong>Stainless</strong> <strong>Steel</strong> Hot Water <strong>Tanks</strong><br />

Dimensional Data<br />

Ø<br />

HOT WATER OUTLET<br />

Ø<br />

T&P RELIEF<br />

VALVE<br />

HOT WATER OUTLET<br />

THERMOMETER<br />

BOILER<br />

FLOW<br />

MANOMETER<br />

T&P RELIEF<br />

VALVE<br />

THERMOMETER<br />

IMMERSION<br />

HEATER<br />

SECONDARY<br />

RETURN<br />

Ø<br />

HOT WATER OUTLET<br />

BOILER<br />

FLOW<br />

SENSOR<br />

BOILER<br />

RETURN<br />

SOLAR<br />

FLOW<br />

SENSOR<br />

H<br />

T&P RELIEF<br />

VALVE<br />

IMMERSION<br />

HEATER<br />

SECONDARY<br />

RETURN<br />

COLD WATER<br />

INLET<br />

BOILER FLOW<br />

THEROMETER<br />

SENSOR<br />

BOILER<br />

RETURN<br />

SOLAR<br />

FLOW<br />

SENSOR<br />

SOLAR<br />

RETURN<br />

H<br />

SENSOR<br />

BOILER<br />

RETURN<br />

SOLAR<br />

FLOW<br />

SENSOR<br />

SOLAR<br />

RETURN<br />

IMMERSION HEATER<br />

INSPECTION<br />

SECONDARY<br />

RETURN<br />

COLD WATER<br />

INLET<br />

H<br />

COLD WATER<br />

INLET<br />

SOLAR<br />

RETURN<br />

DRAIN<br />

DRAIN<br />

170L - 500L 750L - 1000L 1500L - 5000L<br />

Drawing represented without thermal insulation<br />

Note: Immersion socket allows for installation of electric element<br />

(allow for 100mm insulation)<br />

Connections Note: All connections are female<br />

Model<br />

Cold<br />

Water<br />

Inlet<br />

Hot<br />

Water<br />

Outlet<br />

Secondary<br />

Return<br />

Primary<br />

Flow<br />

Top Coil<br />

Primary<br />

Return<br />

Bottom Coil<br />

Primary<br />

Flow<br />

Primary<br />

Return<br />

Sensor Immersion T&P Valve Drain<br />

170 - 300L 20NB 20NB 20NB 20NB 20NB 20NB 20NB 15NB 20NB 20NB -<br />

400 - 500L 25NB 25NB 20NB 25NB 25NB 25NB 25NB 15NB 25NB 20NB -<br />

750L 32NB 32NB 25NB 25NB 25NB 25NB 25NB 15NB 25NB 2 x 20NB 25NB<br />

1000 - 1500L 40NB 40NB 25NB 32NB 32NB 32NB 32NB 15NB 32NB 2 x 20NB 25NB<br />

2000 - 2500L 50NB 50NB 25NB 40NB 40NB 40NB 40NB 15NB 40NB 3 x 20NB 25NB<br />

3500L 50NB 50NB 25NB 40NB 40NB 40NB 40NB 15NB 40NB 3 x 20NB 25NB<br />

4000 - 5000L 80NB 80NB 25NB 40NB 40NB 40NB 40NB 15NB 40NB 4 x 20NB 25NB<br />

Automatic Heating 7


<strong>Thermex</strong> - <strong>Stainless</strong> <strong>Steel</strong> Hot Water <strong>Tanks</strong><br />

Immersion Elements<br />

• As supplementary heating device<br />

• Connection 1 ½”<br />

• Inbuilt thermostat<br />

Single Phase<br />

Part No. Output kW Voltage V Max temp ºC Tank Size<br />

TIHE2KW 2 240/1 PH 70 170L-500L<br />

TIHE3KW 3 240/1 PH 70 170L-500L<br />

3 Phase<br />

Part No. Output kW Voltage V Max temp ºC Tank Size<br />

TIHE6KW 6 400/3 PH 85 750L-1000L<br />

TIHE10KW 10 400/3 PH 85 750L-1000L<br />

8<br />

Automatic Heating


<strong>Thermex</strong> - <strong>Stainless</strong> <strong>Steel</strong> Hot Water <strong>Tanks</strong><br />

Installation Examples<br />

P & I Diagram - Meridian 2 x 120kW Condensing Water Heaters C/W 1000L <strong>Thermex</strong> SS <strong>Tanks</strong><br />

1000L <strong>Thermex</strong><br />

S. S. Tank<br />

Meridian 120<br />

Heater No. 1<br />

Meridian 120<br />

Heater No. 2<br />

Supply<br />

Cold<br />

Water<br />

Fill<br />

Flange Connection<br />

C/W Spacer Piece<br />

Cold Water Supply<br />

Expansion<br />

Tank 35L<br />

P & I Diagram<br />

Meridian 100kW Condensing Water Heater C/W 2 x 500L <strong>Thermex</strong> SS <strong>Tanks</strong><br />

DHW Supply<br />

DHW Supply<br />

Meridian 100<br />

500L<br />

<strong>Thermex</strong> S.S. Tank<br />

Secondary Return<br />

Secondary<br />

Return<br />

Cold<br />

Water Fill<br />

240V 10A<br />

GPO<br />

Scorpion SPA32/80<br />

Gas<br />

DHW Supply<br />

500L<br />

<strong>Thermex</strong> S.S. Tank<br />

Cold Fill<br />

FWMA015<br />

Expansion<br />

Tank 35 L<br />

Secondary Return<br />

Automatic Heating 9


<strong>Thermex</strong> - <strong>Stainless</strong> <strong>Steel</strong> Hot Water <strong>Tanks</strong><br />

Case Studies<br />

10<br />

Automatic Heating


<strong>Thermex</strong> - <strong>Stainless</strong> <strong>Steel</strong> Hot Water <strong>Tanks</strong><br />

Prefab Packages for Fast Installation or Rental<br />

Custom hot water heating system packages are available mounted on prefabricated skid<br />

frames for fast installation or for rental where a temporary system is required.<br />

Automatic Heating 11


Automatic Heating Global Pty Ltd<br />

T. +613 8352 7000<br />

E. sales@automaticheating.com.au<br />

67 Gateway Boulevard, Epping VIC 3076<br />

P.O. Box 35a Epping VIC 3076 Australia<br />

W. automaticheating.com.au 18769 210525

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!