Buffer Memory Buffer memory list<br />

BFM#<br />

(decimal)<br />

280<br />

Meaning Set range Unit Default value Description<br />

<strong>Control</strong>ler 1<br />

281 <strong>Control</strong>ler 2<br />

282 <strong>Control</strong>ler 3<br />

283 <strong>Control</strong>ler 4<br />

284<br />

285<br />

Delay for sensor<br />

monitoring<br />

<strong>Control</strong>ler 5<br />

<strong>Control</strong>ler 6<br />

0 to 30 Minutes 0 Chapter 3.3.9<br />

286 <strong>Control</strong>ler 7<br />

287 <strong>Control</strong>ler 8<br />

288 <strong>Control</strong>ler 9<br />

289 <strong>Control</strong>ler 10<br />

290 Leading value: Proportional band 0 to 500 0.1 72<br />

291 Leading value: Integral time 0 to 1000 100 ms 600 Chapter 3.3.10<br />

292 Leading value: Derivative time 0 to 1000 100 ms 118<br />

293<br />

294<br />

Switching threshold for changing<br />

between lead value and regular PID<br />

constants<br />

<strong>Control</strong>ler 1<br />

295 <strong>Control</strong>ler 2<br />

296 <strong>Control</strong>ler 3<br />

297 <strong>Control</strong>ler 4<br />

298<br />

299<br />

Heating currents<br />

<strong>Control</strong>ler 5<br />

<strong>Control</strong>ler 6<br />

300 <strong>Control</strong>ler 7<br />

301 <strong>Control</strong>ler 8<br />

302 <strong>Control</strong>ler 9<br />

303 <strong>Control</strong>ler 10<br />

MITSUBISHI ELECTRIC 3 - 9<br />

0 to 1000 0.1 K 70 Chapter 3.3.11<br />

0 to 10000 0.01 V 0<br />

304 Maximum leakage current 0 to 10000 0.01 V 0<br />

305<br />

<strong>Control</strong>ler 1<br />

306 <strong>Control</strong>ler 2<br />

307 <strong>Control</strong>ler 3<br />

308 <strong>Control</strong>ler 4<br />

309<br />

310<br />

Cooling constant<br />

<strong>Control</strong>ler 5<br />

<strong>Control</strong>ler 6<br />

311 <strong>Control</strong>ler 7<br />

312 <strong>Control</strong>ler 8<br />

313 <strong>Control</strong>ler 9<br />

314 <strong>Control</strong>ler 10<br />

Tab. 3-9: Buffer memory areas for set values (5)<br />

Setting of a min.<br />

heating current.<br />

If the measured<br />

value of the heating<br />

current is<br />

less than the<br />

min. current, an<br />

alarm is issued.<br />

The maximum<br />

leakage current<br />

is the current<br />

which may flow<br />

when all the<br />

heating zones<br />

are switched off<br />

0 to 500 0.1 180 Chapter 3.3.128