Views
5 years ago

RE10TC Temperature Control Module Operating manual

RE10TC Temperature Control Module Operating manual

Details of the set

Details of the set values Buffer Memory 3.3.18 Monitoring of limits ON/OFF (BFM #342 to BFM #345) The monitoring of each limit or warning value can be selected ON or OFF. BFM #342: Monitoring of lower limits ON/OFF BFM #343: Monitoring of upper limits ON/OFF BFM #344: Monitoring of lower warning values ON/OFF BFM #345: Monitoring of upper warning values ON/OFF Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Controller 10 9 8 7 6 5 4 3 2 1 Fig. 3-16: Selection of limits and warnings 3.3.19 Monitoring of heating currents ON/OFF (BFM #347) This address is used to select the controller for which the heating current is to be monitored. BFM #347: Monitoring of heating current ON/OFF Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Controller 10 9 8 7 6 5 4 3 2 1 Fig. 3-14: Contents of buffer memory address 347 3.3.20 Watchdog (BFM #348) Bit = 1: Monitoring ON Bit = 0: Monitoring OFF TC00025C Bit 0 in BFM #348 is set by the RE10TC. By resetting the bit in the sequence program of the PLC and checking that the bit has been switched ON again, the operation of the RE10TC can be confirmed. BFM #348: Watchdog Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Fig. 3-15: Watchdog flag in buffer memory address 348 1 Bit = 1: Monitoring ON Bit = 0: Monitoring OFF Bit 0 is set by the RE10TC TC00023C TC00026C 3-22 MITSUBISHI ELECTRIC

Installation Name of each part 4 Installation 4.1 Name of each part � Connections for analog inputs (for description refer to 4.3) � Loop-LED: Flickering indicates readyness of the module � Power-LED: Lit when the power supply of the outputs is on � LEDs for indicating a switched ON heating output � LEDs: Lit when the respective cooling output is ON � Connections for heating and cooling outputs (refer to 4.3) MITSUBISHI ELECTRIC 4 - 1 � TC0+ TC1+ TC2+ TC3+ TC4+ TC5+ TC6+ TC7+ TC8+ TC9+ CT+ URT+ IRT+ AGND +24V GND TC0- TC1- TC2- TC3- TC4- TC5- TC6- TC7- TC8- TC9- CT- URT- IRT- Fig. 4-1: Temperature control module RE10TC � +24VY COM YH0 YH1 YH2 YH3 YH4 YH5 YH6 YH7 YH8 YH9 Y0 Y1 +12V VPP YC0 YC1 YC2 YC3 YC4 YC5 YC6 YC7 YC8 YC9 Y2 Y3 GND GND � 2 RE10TC � Heating Output Cooling Output 8 9 0 8 9 0 Cooling Output Y - Output � Loop POWER � TE00007C

Operating Manual OLED Control - Toni Maroni GmbH
DM8 Module - Operator's Manual - RevA - Alesis
Temperature controllers - leaflet - Elektra
OPERATION MANUAL - Best Service
Electronic Temperature Controller - Staveb AG
Temperature Controllers - Home | Kimray Mobile
OPERATOR'S MANUAL - LWRC International, LLC
Operators Manual
Operators Manual
1000 Manual - Dart Controls
3. HOUSE RULES COLD TEMPERATURE CONTROL
OPERATIONAL MANUAL - Test and Measurement
PIP 6 Temperature Controlled Pipette Puller
Controller for operation of evaporator - Berling
SCOPE OF MANUAL - Eastech Flow Controls
OPERATING MANUAL - Bad Request
1747-6.5.5, SL 500 DeviceNet Scanner Module User Manual
Operator Terminal System Manual - 11276916.pdf
Operation Manual - Key Digital
BV100 OPERATIONS MANUAL
Manual on Operation and - CDD Society
Operating Manual Hopper loader
Installation and Operations Manual - Intaeco
BV100 OPERATIONS MANUAL - Sensis
OPERATORS MANUAL - CAO Group