Wiring Installation

Wiring Installation Terminal Meaning Assignment �24V Power supply Positive pole of 24 V DC voltage for supplying the module GND 24 V DC Negative pole of 24 V DC voltage for supplying the module FE FE Function earth Module grounding TC0� TC0� Temperature zone 1 TC1� TC1� Temperature zone 2 TC2� TC2� Temperature zone 3 TC3� TC3� Temperature zone 4 TC4� Temperature zone 5 TC4� Inputs for thermocouples TC5� (analog inputs) TC5� Temperature zone 6 TC6� TC6� Temperature zone 7 TC7� TC7� Temperature zone 8 TC8� TC8� Temperature zone 9 TC9� TC9� Temperature zone 10 CT� Input for heating current Positive pole of the signal voltage (0 to 10 V) CT� monitoring Negative pole of the signal voltage (0 to 10 V) URT� Voltage connections URT� Reference temperature IRT� input (KTY) IRT� Connections of constant current supply AGND Analog ground n. c. Not configured — Tab. 4-1: Assignment of the upper terminal block of the FX2N-RE10TC 4-4 MITSUBISHI ELECTRIC

Installation Wiring Terminal Meaning Assignment �24VY Power supply Positive pole of 24 V DC voltage for supplying the outputs COM 24 V DC Negative pole of 24 V DC voltage for supplying the outputs FE FE Function earth Module grounding YH0 YC0 Output “heating” Output “cooling” Temperature zone 1 YH1 YC1 Output “heating” Output “cooling” Temperature zone 2 YH2 YC2 Output “heating” Output “cooling” Temperature zone 3 YH3 YC3 Output “heating” Output “cooling” Temperature zone 4 YH4 YC4 Output “heating” Output “cooling” Temperature zone 5 YH5 YC5 Output “heating” Output “cooling” Temperature zone 6 YH6 YC6 Output “heating” Output “cooling” Temperature zone 7 YH7 YC7 Output “heating” Output “cooling” Temperature zone 8 YH8 YC8 Output “heating” Output “cooling” Temperature zone 9 YH9 YC9 Y0 Output “heating” Output “cooling” Temperature zone 10 Y1 Y2 Y3 �12V GND(�12V) VPP GND (VPP) Not connected — 12 V DC voltage Reserved for works after-sales service Programming voltage Reserved for works after-sales service Tab. 4-2: Assignment of the upper terminal block of the FX2N-RE10TC MITSUBISHI ELECTRIC 4 - 5

OPERATING MANUAL - Hettich AG, CH
Installation and Operating Manual 262-30T Temperature ... - Crompton
Operating Manual OLED Control - Toni Maroni GmbH
Module type Temperature Controller (ECNO:1162b) - Fuji Electric
DM8 Module - Operator's Manual - RevA - Alesis
502914 - Orbit3 Module manual - K- Pro Soft
Temperature Controllers TW, TO, TP Series - Neofyton
Operational Manual for Implementation of Malaria ... - NVBDCP
Mountain Computer ROMPlus+ Operating Manual
Temperature & Humidity Control Systems for the Wine Industry
Download Operations Manual - Humminbird
Operator Manuals - St. James Church in Weddington
IBBS Field operations and monitoring manual English
Honeywell Modulating Electronic Control Thermostats - Kele
THE DEBT RESISTORS' OPERATIONS MANUAL
THE DEBT RESISTORS' OPERATIONS MANUAL
OPERATION MANUAL - Daikin AC
Biomass controllers - TEM