Installation RSU-503 Redundancy Switch Unit Figure 2-2. RSU-503 External Connections 16 Rev. 8

RSU-503 Redundancy Switch Unit Installation 2.4.1 TX/IF Output (J1, J5) The TX/IF Output connectors are TNC connectors, each with an impedance of 50Ω. These connectors carry the IF uplink signal to the online RFT (Unit A or B). 2.4.2 RX/IF Input (J2, J6) The RX/IF Input connectors are TNC connectors, each with an impedance of 50Ω. These connectors carry the IF downlink signal from the online RFT (Unit A or B). 2.4.3 TX/RF Input (J3, J7) The TX/RF Input connectors are type N connectors, each with an impedance of 50Ω. These connectors carry the transmit uplink signal from the online RFT (Unit A or B). Rev. 8 17