Views
5 years ago

RSU-503 Redundancy Switch Unit Installation ... - Comtech EF Data

RSU-503 Redundancy Switch Unit Installation ... - Comtech EF Data

Installation RSU-503 Redundancy Switch Unit Figure 2-5. RSU-503, J10 to Waveguide Switch Plate Note: Be sure to connect the primary RFT (A) to J4, and the backup RFT (B) to J8. 24 Rev. 8

RSU-503 Redundancy Switch Unit Installation 2.6 Addressing The following are the factory default addresses: • Switch is set to address 1 • RFT A is set to address 2 • RFT B is set to address 3 The proper M&C cable hook-up is critical: • RFT A must be connected to the switch Port A • RFT B must be connected to the switch Port B Note: If these connections are reversed, no communications will take place. Rev. 8 25

Ethernet Switches - Installation, Troubleshooting ... - SWS a.s.
Software Installation and Licensing ... - Comtech EF Data
CXU-810 RAN Optimizer - Comtech EF Data
Converters MBT-5000 & MBT-5003 L-Band Up ... - Comtech EF Data
WAN_Point-to-Point Protocol - Comtech EF Data
Using This Document Series - Comtech EF Data
2.5 Configuring the Digital Data Channels - Comtech EF Data
Redundant Backup Switch (RBS) User Guide - Voltron
Agilent 34970A Data Acquisition/Switch Unit - Northwestern University
Xilinx DS202 Virtex-5 FPGA Data Sheet: DC and Switching ...