Views
5 years ago

installation and operations manual - Rose Electronics

installation and operations manual - Rose Electronics

Safety

Safety and EMC Regulatory Statements Safety information 18 Documentation reference symbol. If the product is marked with this symbol, refer to the product documentation to get more information about the product. WARNING A WARNING in the manual denotes a hazard that can cause injury or death. CAUTION A CAUTION in the manual denotes a hazard that can damage equipment. Do not proceed beyond a WARNING or CAUTION notice until you have understood the hazardous conditions and have taken appropriate steps. Grounding These are Safety Class I products and have protective earthing terminals. There must be an un-interruptible safety earth ground from the main power source to the product’s input wiring terminals, power cord, or supplied power cord set. Whenever it is likely that the protection has been impaired, disconnect the power cord until the ground has been restored. Servicing There are no user-serviceable parts inside these products. Only service-trained personnel must perform any servicing, maintenance, or repair. The user may adjust only items mentioned in this manual. MULTISTATION PC INSTALLATION AND OPERATIONS MANUAL

TROUBLESHOOTING Keyboard or mouse on remote user module does not work. � Cable is loose; re-seat keyboard or mouse cable at the CPU and the remote user module and reset the keyboard and mouse (Refer to Figure 12) � Keyboard and mouse cables reversed. Boot-up sequence appears on the Remote user module monitor only � The system BIOS is detecting the MultiStation PC graphic adapter as the main display adapter. To correct this problem there are two options, either the dipswitches located on the MultiStation PC’s PCI card need to be changed or the BIOS/CMOS settings need to be changed. OPTION 1 – Change dipswitch settings � First verify that the two dipswitches located on the MultiStation PC’s PCI card are both in the “OFF” position. (Refer to Figure 1) If the dipswitches are not in the “OFF” position, shut down the computer, set both switches to “OFF” and restart the computer. If the boot-up sequence displays on the monitor connected directly to the PC, proceed with your installation. If not: � Repeat the process of powering down the computer, changing the dipswitch settings and restarting the computer for each of the settings until one of the settings resolves the problem. Settings are “ON”, “OFF” / “OFF”, “ON” / “ON”, “ON”. If this does not correct the problem set the dipswitches back to “OFF”, “OFF” and try Option 2A and/or Option 2B. OFF/OFF OFF/ON ON/OFF ON/ON (Default) OPTION 2 – BIOS/CMOS settings for AGP video adapter � If the host display is AGP, verify that the BIOS setup shows the AGP adapter as the host adapter Following are several examples of BIOS setups for different PC’s. 1. Boot your system and enter the BIOS setup. Select “Integrated Peripherals” and press enter. Verify that the setting for “Init Display First” is correct. If the display adapter is AGP, this item should show “AGP”. MULTISTATION PC INSTALLATION AND OPERATIONS MANUAL 19

Operating manual - JDC Electronic SA
Installation and Operations Manual - Intaeco
Installation, Operation, Repair and Parts Manual - Hayes Spraying
Installation and Operation Manual For Hunter Ceiling ... - Hunter Fan
Installation & Operation Manual for WarmlyYours ... - Heater Home
Installation and Operating Manual System Protection Relay Energy ...
Installation and Operation Manual For Hunter Ceiling Fans
INSTALLATION MANUAL
8 channel stereo mic/line mixer installation and operation manual
Operators and installation Manual Tron UAIS TR-2500 - Jotron
Enclosure Manual - Steren Electronics
Installation and Operation Guide - AJA
Zeus Installation Manual - MRAD
Harveytile Installation Manual - Macsteel
Installation Manual-A - Thermo King
PowerCore 6000 Manual English - TC Electronic
Installation manual - Warmup
Installation manual - Warmup
Installation and Operation Manual For Hunter Ceiling ... - Hunter Fan
Operation Manual Broadcast Converter - Go Electronic
Installation Manual - CertainTeed