SHAMAR ROBERTS PORTFOLIO -2024
Transform your PDFs into Flipbooks and boost your revenue!
Leverage SEO-optimized Flipbooks, powerful backlinks, and multimedia content to professionally showcase your products and significantly increase your reach.
ARCHITECTURE
PORTFOLIO
"Architecture should transcend mere
construction; it should shape spaces that
inspire, connect, and enrich the human
experience."
Shamar Roberts
VOLUME 1 | APRIL 2020 ISSUE
2 |
BY:SHAMAR ROBERTS
MORGAN STATE UNIVERSITY SA+P
MORGAN STATE UNIVERSITY SA+P | 3
Table of Contents
01
HYBRID HOUSING
02
LIFT
03
NKBA KITCHEN DESIGN
04
PROFESSIONAL WORK SAMPLES
ABOUT ME
Hailing from Guyana, I am an architect who followed my lifelong passion for
design to the United States in 2019. The diverse architectural influences in
Guyana ignited my fascination with design from a young age. Upon arriving in
the U.S., I embarked on an enriching academic journey, embracing the variety
of architectural styles and philosophies. My passion for architecture allowed
me to immerse myself in a new culture and connect with people from diverse
backgrounds, further broadening my architectural horizons.
Beyond academics, I have actively engaged in extracurricular activities,
design competitions, and internships, gaining practical experience and
honing my skills. Participating in a sustainable design project was a defining
moment, highlighting the positive impact thoughtful architecture can have on
communities and the environment.
05
ARCHITECTURAL PHOTOGRAPHY
My ultimate goal as an architect is to use design as a catalyst for positive
change, creating spaces that inspire and serve the needs of diverse
communities. With a profound commitment to contributing meaningfully to the
field, I eagerly look forward to the endless opportunities that lie ahead in the
world of architecture.
4 |
MORGAN STATE UNIVERSITY SA+P | 5
MORGAN STATE UNIVERSITY SA+P
“As designers, we have such
power to make design change
the world. We really need to
make better use of our platform
and do stuff that is useful”
— Yinka Ilori
6 |
MORGAN STATE UNIVERSITY SA+P | 1
MORGAN STATE UNIVERSITY SA+P
1 | HYBRID HOUSING
Project 1, Hybrid housing ,explores innovative solutions for low-density urban
housing using hybrids of the two common urban housing types – the Rowhouse
and the Low-rise Apartment. Working in groups of two students, investigated the
spatial possibilities and propose a hybrid housing type that combines features of
both.
2 | HYBRID HOUSING
MORGAN STATE UNIVERSITY SA+P | 3
P
NATURE CENTER / AQUARIUM
1 | SITE PLAN
The site shows a proposed hypothetical site which includes layout for proposed
hybrid housing concept as well as additional site programs.
RH
RH
The concept for the site layout was intended to have 4 hybrid housing buildings on
each corner with additional program on the inner side to divert foot traffic towards
that central location, making it the central community node.
The idea to split the site symmetrically sought to provide a more intimate design with
the four buildings and give a third of the site back to the communal greenspace while
BOARD
WALK
LOBBY /
LOUNGE
STORAGE
TRASH
STORAGE
LOBBY /
LOUNGE
accounting for the design requirement of 24 units maximum.
RH
RH
SEAFOOD
FLORIST
CONCEPT DIAGRAMS
BAKERY
BIKE SHOP
RH
RH
LOBBY /
LOUNGE
STORAGE
TRASH
STORAGE
LOBBY /
LOUNGE
MASSING CONCEPT
VIEW ANALYSIS
RH
RH
4 |
MORGAN STATE UNIVERSITY SA+P | 5
1 | ELEVATIONS
The warm and welcoming facade
of our hybrid housing construction
The warm and welcoming facade of our hybrid housing construction exudes
exudes charm and comfort. Soft,
charm and comfort. Soft, earthy tones and carefully chosen natural materials
earthy tones and carefully chosen
blend seamlessly to create an inviting atmosphere. Large windows framed by lush
natural materials blend seamlessly
greenery allow natural light to flood in, while a cozy front porch beckons residents
to create an inviting atmosphere.
and guests to relax and connect. This facade is a symbol of the harmonious blend
Large windows framed by lush
greenery allow natural light to flood
in, while a cozy front porch beckons
residents and guests to relax and
connect. This facade is a symbol of
the harmonious blend of modern
living and timeless warmth.
SOUTH ELEVATION
WEST ELEVATION
6 |
MORGAN STATE UNIVERSITY SA+P | 7
MORGAN STATE UNIVERSITY SA+P
1 | UNIT LAYOUTS
The design of each building offers 2 unit types, an option for 2 bedroom and an option for 3 bedroom.
KITCHEN
LNDY
P.
BATH
WIC
LIVING RM
BR 2
BATH
BR 3
PRIMARY
BEDROOM
TYPE A
LIVING RM
LNDY
BR 2
KITCHEN
PRIMARY
BEDROOM
TYPE B
BATH
P.
BATH
TOWNHOUSE LAYOUT
WIC
Picture a unique hybrid housing
building that seamlessly combines
the best of both worlds. In the heart
of the structure, you'll find a stylish
three-level apartment, offering
modern living spaces and panoramic
views. On each end, there are threelevel
townhouses, standing tall and
elegant. This layout creates a dynamic
architectural balance, catering to
various preferences. Whether you
crave the openness of an apartment
or the cozy charm of a townhouse,
this hybrid building provides
the perfect blend for a diverse
community.
LOBBY /
LOUNGE
UNIT A
2 BR, 2 BATH
STORAGE
UNIT B
3 BR, 2 BATH
UNIT A
2 BR, 2 BATH
LEVEL 1 LEVEL 2
UNIT B
3 BR, 2 BATH
COMMUNITY
GARDEN
OUTDOOR GRILL
/ PICNIC AREA
KITCHEN
DINING
ROOM
GARAGE
LEVEL 1
LEVEL 3
PDR
LIVING
ROOM
OFFICE /
PLAYROOM
LEVEL 2
ROOF
PRIMARY
BEDROOM
BATH
LNDY
BEDROOM
2
LEVEL 3
8 |
MORGAN STATE UNIVERSITY SA+P | 9
MORGAN STATE UNIVERSITY SA+P
1 | HYBRID HOUSING
The design of each building offers 2 unit types, an option for 2 bedroom and an option for 3 bedroom.
ROOF TOP
GRILL
PICNIC AREA
GARDEN
10’
UNIT A
2 BR
2 BATH
UNIT B
3 BR
2 BATH
LEVEL 3
UNIT A (x1)
UNIT B (x1)
11’
UNIT A
2 BR
2 BATH
UNIT B
3 BR
2 BATH
LEVEL 2
UNIT A (x1)
UNIT B (x1)
11’
LOBBY / LOUNGE
LEVEL 1
LOBBY
MAIL ROOM
OPEN LOUNGE
LIBRARY
12’
EAST/WEST SECTION
SCALE: 1/8” = 1’
APARTMENT SECTION 1
AXONOMETRIC VIEW
10 |
MORGAN STATE UNIVERSITY SA+P | 11
MORGAN STATE UNIVERSITY SA+P
2 | BARBARA G LAURIE STUDENT DESIGN
The Williams & Russell Project is a restorative justice project that addresses systemic
injustices against Portland’s Black community on land condemned by
Prosper Portland and the City of Portland in the early 1970s under urban renewal for
an expansion for Emanuel Hospital (now Legacy Health). Historically, the
site once was part of a thriving community that housed the majority of African
Americans in Portland and Oregon. The site was previously referred to as the
Hill Block, which is the historic name of the building that once occupied the site and
served as the center of the African American commercial district from the
1940s to the early 1960s. The Hill Block building’s onion-domed cupola is now located
in Eliot Neighborhood’s Dawson Park.
The land is being donated back to the Black community via the
Williams & Russell CDC to realize five community priorities:
• Support for Entrepreneurs
• Affordable Rental Housing
• Homeownership
• Education / Workforce Training
• Community Space
12 | HYBRID HOUSING
MORGAN STATE UNIVERSITY SA+P | 13
28’
23.5’
5
L
E
V
E
L
S
17’
WESTERN
EXPOSURE
EASTERN
EXPOSURE
8’
4’
2 | PROJECT TITLE-LIFT
2 | THE CONCEPT
JUNE 25
N
OUTDOOR SPACE
PUBLIC ACCESS
E
DEC. 25
OUTDOOR SPACE
W
S
STEP 1 STEP 2 STEP 3 STEP 4
STEP 5 STEP 6 STEP 7
PROJECTED OWNER
USER TYPE
PROJECTED
USER TYPE
INCUBATOR WORKFORCE
PROJECTED
USER TYPE
RETAIL
CHARCTERISTICS
SELF EMPLOYED/
DOUBLE INCOME
WORK FROM HOME
NO KIDS
HOUR
AVG. DAILY SCHEDULES
TIME SPENT
10
ELDERLY/RETIRED
65% 25% 10% 75-83k
28-55 YRS 28-35 YRS 65-75 YRS
• SELF OWNED BUSINESS RETAIL W/ INDV. MARKET
• SUB-LEASE OPTION ON SECOND LEVEL
• IDEAL FOR AGING & TRANSITIONING IN PLACE
7.5
5
2.5
0
Sleeping
Eating
Exercising
Reading
Working
Family
Meditating
Socializin g
AVG. TURNOVER FOR
RESIDENTS (YRS)
3.5
DOUBLE INCOME
NO KIDS
2.5
YRS.
YRS.
SELF EMPLOYED/
WORK FROM HOME
10+
ELDERLY/RETIRED
129-138k
DOUBLE INCOME
NO KIDS
ELDERLY/RETIRED
47-84k
SELF EMPLOYED/
WORK FROM HOME
YRS.
HOUR
CHARCTERISTICS
PAITIENTS
55%
TRAVELING NURSE
30%
LONG TERM NURSE
15%
1-80 YRS
26-32 YRS
35-55 YRS
84-106k
• TRAINING FOR TRAVELING AN LONG TERM NURSES
TRAVELING NURSE
• INTEGRATED SUB-LEASE OPTION FOR TRAVELING NURSE
• NURSE WORKFORCE ENGAGES COMMUNITY W/ PROACTIVE & REHABILITATIVE TRAIN-
ING
• ESTABLISHES CONTINUED CONNECTION TO LEGACY HEALTH HOSPITAL
AVG. TURNOVER RATE OF USAGE
AVG. DAILY SCHEDULES
TIME SPENT
10
7.5
5
2.5
0
Sleeping
Eating
Exercising
Reading
Working
Family
Meditating
Socializin g
3-5 YRS.
LONG TERM NURSE
3-6
100+
PAITIENTS PER WEEK
72-91k
LONG TERM NURSE
MOS.
TRAVELING NURSE
HOUR
CHARCTERISTICS
GENERAL CONSUMER HOME & MKT OWNERS LEASED MKT OWNERS
97% 2% 1%
8-80 YRS 36-55 YRS 28-55 YRS
54-72k
LEASED
• RESIDENT OWNED & INFLUENCED COMMUNITY MARKET
MKT OWNERS
• CIRCULATION OF INCOME WITHIN THE COMMUNITY
• MEZZANINE ALLOWS FOR MULTI LEVEL SHOPPING EXPERIENCE
• INTEGRATES SHOPPING EXPERIENCE WITH DINING
AVG. TURNOVER RATE OF USAGE
AVG. DAILY SCHEDULES
TIME SPENT
10
7.5
5
2.5
0
Sleeping
Eating
Exercising
Reading
Working
Family
Meditating
Socializin g
10+
HOME & MKT OWNERS
300+
GENERAL CONSUMER
PER DAY
YRS.
1-3
84-105k
HOME &
MKT OWNERS
YRS.
LEASED MKT OWNERS
LIFT
To be surrounded by people who look like you, immersed in a community with a
collective culture, and exposed to opportunities that seem too good to be true, Albina
today would be a daydream. As an exploration we observed the adversities of this
historically displaced community and pursued the challenge of resolving it with the
intent of empowering and lifting Albina to its fullest potential. Our design attempts
to harmonize the power held when the residents are the ones with the authority
to elevate each other by having the capacity of choice, influence, and income. Self-
Advocacy is a learnt skill in minority communities, and exactly what the foundation of
our concept is built on. We’ve created a pliable program, built to change, grow, and
interconnect based on the evolution of this community. Striving for a long standing
and established sense of place that can stand the test of time.
L R
L
R
L R
2
1
•
•
•
•
•
•
•
•
3
•
•
•
PROJECTED
USER TYPE
CHARCTERISTICS
RETIRED SENIOR
CITIZENS
PROJECTED
USER TYPE
CHARCTERISTICS
SINGLE PARENTS/GRAND FAMILY
JOB TRANSPLANT
AVG. DAILY SCHEDULES
TIME SPENT
10
RENTAL
STUDENTS/RECENTS
GRADS
55% 35% 10%
35-70 YRS 28-35 YRS 21-26 YRS
• INCREASED OUTDOOR AMENITY SPACE
• IMMEDIATE WALKABLE ACCESS FOR VARIOUS URBAN PROGRAMMING
• INCREASED INVESTMENT WITHIN THE COMMUNITY
HOUR
7.5
5
2.5
0
AFTER SCHOOL
K-12 CHILDREN
AVG. DAILY SCHEDULES
TIME SPENT
10
MULTI-GENERATIONAL CENTER
MIDDLE AGE
DROP OFFS/CAREGIVERS
60% 25% 15%
65-70 YRS 4-18 YRS 35-45 YRS
• LIFE CYCLE COMMUNITY INTEGRATION THAT ADDRESSES GENERATIONAL
COMMUNITY NEEDS
• BUILT IN CONNECTION TO INCUBATOR TO FACILITATE PROACTIVE HEALTHY
LIFESTYLE TO COMMUNITY
HOUR
7.5
5
2.5
0
Sleeping
Eating
Exercising
AVG. TURNOVER RATE OF USAGE (PER
WEEK)
2
5
AVG. TURNOVER FOR
RESIDENTS (YRS)
10+
YRS.
SINGLE PARENTS/GRAND FAMILY
2.5
YRS.
STUDENTS/RECENT
GRADS
3-4
2
YRS.
JOB TRANSPLANT
53-60k
SINGLE PARENTS/
GRAND FAMILY
60-70k
JOB TRANSPLANT
45-52k
STUDENTS/RECENT
GRADS
Sleeping
Eating
Exercising
Reading
Working
Family
Meditating
Socializin g
Reading
Working
Family
Meditating
Socializin g
RETIRED SENIOR
CITIZENS
AFTER SCHOOL
K-12 CHILDREN
75-83k
RETIRED SENIOR
CITIZENS
63-75k
MIDDLE AGE
DROP OFFS/CAREGIVERS
MIDDLE AGE
DROP OFFS/CAREGIVERS
14 |
MORGAN STATE UNIVERSITY SA+P | 15
MORGAN STATE UNIVERSITY SA+P
MORGAN STATE UNIVERSITY SA+P | 17
16 |
LEVEL 4 LEVEL 5 ROOF
FORSALE LEVEL 1 FORSALELEVEL 2
MEZZANIE LEVEL
MORGAN STATE UNIVERSITY SA+P
2 | BARBARA G LAURIE STUDENT DESIGN
GROUND FLOOR SITE
LEVEL 2 LEVEL 3
UNIT MIX
2 | BARBARA G LAURIE STUDENT DESIGN
4' - 6"
EASTERN ELEVATION
WESTERN ELEVATION
COURTYARD ELEVATION
NORTHERN ELEVATION
20 |
MORGAN STATE UNIVERSITY SA+P | 21
MORGAN STATE UNIVERSITY SA+P
3 | NKBA KITCHEN&BATHROOM DESIGN
The modern kitchen design with an island that sits three, a cooktop, and a command center is
a perfect balance of form and function. The main focus of this design is to create a space that
is efficient, comfortable, and aesthetically pleasing.The first element to consider is the island. It
should be large enough to accommodate three people comfortably and have enough space to
prepare food.The countertop material is durable and easy to clean. The island also has sample
storage space for kitchen tools and appliances.The cooktop is an essential part of any kitchen, and
is placed in an easily accessible location. The cooktop is large enough to handle multiple pots and
pans, and the ventilation system is efficient to remove cooking odors and smoke.The command
center is located near the cooktop and the island. It has a largetouchscreen display that can be
used to access recipes, cooking tips, and other kitchen-related information. It also has a docking
station for smartphones and tablets, so users can easily access their favorite cooking apps.
A combination of overhead and under-cabinet lighting can be used to create a warm,
inviting ambiance. Finally, the overall design of the kitchen is cohesive and stylish. The
color scheme is simple and elegant, and the materials used are of high quality. The
cabinetry is sleek and modern, and the countertops is made of a durable and easyto-maintain
material like granite . In conclusion, the modern kitchen design with an
island that sits three, a cooktop,and a command center is the perfect combination of
form and function. By carefully considering each element of the design, you can create
a space that is efficient, comfortable, and stylish.
22 |
MORGAN STATE UNIVERSITY SA+P | 23
3 | NKBA KITCHEN & BATHROOM DESIGN
FLOOR PLAN
77”
183 1/2”
PANTRY
54” 8”
38” 55 1/2” 37”
36”
60”
2
48”
60”
1
102”
REF
KITCHEN
CEILING 96”
”
97 1/2”
72”
77”
183 1/2”
S
PANTRY
MECHANICAL PLAN
54” 8”
38” 55 1/2” 37”
12” S
24”
S
S
S
D
KITCHEN
CEILING 96”
REF
97 1/2”
42” AFF
COFFEE
SYSTEM
42” AFF
72”
Symbol Legend
DUPLEX OUTLET
QADRUPLEX OUTLET
GFCI OUTLET
REFRIGERATOR
DISHWASHER
HOOD
COOKTOP
MICROWAVE
COFFEE SYSTEM
TELEVISION
CABLE OUTLET
REF
DW
HOOD
CT
MICRO
T
O
96”
LIGHT
70 1/2”
COMMAND
CENTER
72”
WALL
OVEN
DW
86 5/8”
70 1/2”
COMMAND
CENTER
WALL
OVEN
DW
86 5/8”
UNDER CABINET LIGHT-
ING
CHANDELIER
SWITCH
S
104 3/4”
78 1/2”
SHAMAR KITCHEN PROJECT 05/07
FLOOR PLAN
KBD
104 3/4”
78 1/2”
42” AFF
SHAMAR KITCHEN PROJECT 05/07
MECHANICAL PLAN
KBD
THREE WAY SWITCH
DIMMER
s3
D
24 |
MORGAN STATE UNIVERSITY SA+P | 25
MORGAN STATE UNIVERSITY SA+P
3 | NKBA KITCHEN & BATHROOM DESIGN
ELEVATION 1
ELEVATION 2
36” 24” 27” 27” 27”
26”
96”
18”
96”
32 1/2”
18”
34 1/2”
102”
96” 24” 6”
14 1/2” 20 1/4”
25”
SHAMAR KITCHEN PROJECT 05/07
SHAMAR KITCHEN PROJECT 05/07
ELEVATION VIEW
KBD
ELEVATION VIEW
KBD
26 |
MORGAN STATE UNIVERSITY SA+P | 27
MORGAN STATE UNIVERSITY SA+P
SCALE
24' GRAB N GO SDK (R)
GRAB N GO
DELI
GRAB N GO
DELI
3- TEIR CHEESE
ISLAND
3- TEIR CHEESE
ISLAND
SALAD BAR 2
SOUP END
PRODUCE SC
FRIDGE
COUNTER W/DOORS OR DRAWERS BELOW
SEAFOOD
ICE BIN
12' SERVING
DELI
8" GWG HOT
CASE (N)
c
4 | TENANT FITOUT
KEY PLAN
NOT TO SCALE
AREA OF WORK /
KITCHEN EXPANSION
6" SUSHI (N)
8 WELL HOT
FOODS
4' PASTRY (N)
EX
SCALE
SCALE
EX
SLICER ON
STAND
SLICER ON
STAND
SLICER ON
STAND
SLICER ON
STAND
DELI
STAINLESS
STEEL TABLE
STAINLESS
STEEL TABLE
STAINLESS
STEEL TABLE
DELI
EX
DELI COOLER
WARE WASHING
ROOM
HOOD
PRESSURE
FRYER (ELEC)
STAINLESS
STEEL TABLE
BREADING
EX
EX
72" WIDE
FLORAL
COOLER
ELEC
8
8
10
9
11
13
EX
KITCHEN /
COOKING AREA
19'-4" x 36'-1"
5
12
ELEC
42" WIDE
7
7
1
EQUIPMENT LIST
THE CLIENT WILL BE RESPONSIBLE FOR THE HEALTH PERMIT AND ALL
ASSOCIATED SUBMISSIONS, COMMENT RESPONSES, ETC.
OWNER TO CONFIRM EQUIPMENT - LIST IS BASED ON EQUIPMENT THAT WAS
SPECIFIED IN THE B. GREEN & COMPANY KITCHEN PROJECT PROVIDED BY
SAVOY BROWN.
1. STAINLESS STEEL 60" TABLE (BY OWNER)
2. STAINLESS STEEL 72" TABLE
3. DRY STORAGE SHELVING, 24 X 60 (BY OWNER)
4. LEGAL FOR TENDER PORTION SCALES
5. 2 DOOR REFRIGERATOR, MOBILE
6. BLAST CHILLER
7. DOUBLE DECK COMBI OVENS, SELF-VENTING SYSTEM WITH STEAM
FILTERS (ONE FUTURE)
8. GAS FRYER
9. 6-BURNER RANGE WITH CABINET BASE, MOBILE
10. EQUIPMENT STAND WITH MODULAR GRIDDLE, MOBILE
11. 40-GALLON TILTING KETTLE WITH PANTRY FAUCET
12. MICROWAVE STEAMER (x2) STACKED ON RACK
13. TBD - LOW PROFILE EVAPORATOR COILS, +43 DEG. F. (OWNER TO
CONFIRM)
14. TBD - EVAPORATOR COILS, +43 DEG. F. (OWNER TO CONFIRM)
15. OVERHEAD SHELVES
3
3
3
3
NEW 8' WIDE
OVERHEAD DOOR
42" WIDE
STORAGE
19'-7" x 8'-10"
COOLER
19'-0" x 20'-0"
ELEC
ELEC
72" WIDE
SLIDING DOOR
3 3
EX
ARCHITECT / MEP ENGINEER: PROJECT MANAGER: CONTRACTOR:
REV. NO. DATE
DESCRIPTION
EX
FLORAL
COOLER
COFFEE
SERVICE
COUNTER
ICE
COFFEE POTS
COOLER
FREEZER
5
2
EX.
SPRINKLER
2
72" WIDE
4
2
2 4 2
1
4
2
FOOD PREP
19'-4" x 24'-5"
6
42" WIDE
FOOD PREP
32'-0" x 18'-11"
4
4
2
48" WIDE
2
FREEZER
8'-0" x 12'-0"
9
2
2
ADJACENT TENANT
PROJECT:
GREEN VALLEY MARKETPLACE - KITCHEN EXPANSION
SUITE A
8095A EDWIN RAYNOR BLVD.
PASADENA, MARYLAND 21122
MAR 2023
28 |
EX
TEST FIT NOTES:
EX
ADA IMPROVEMENTS BEYOND THE EXTENT OF WORK WERE NOT INCLUDED FOR THIS PROEJCT.
SHOULD THE AHJ REQUIRE ADA IMPROVEMENTS OUTSIDE OF THE EXTENT OF WORK SHOWN
HERE AN ADDITIONAL AGREEMENT WILL BE REQUIRED.
MEP HAS NOT COMPLETED THEIR SURVEY; THEIR FINDINGS MAY IMPACT THE DESIGN. IT IS OUR
ASSUMPTION THAT THERE IS AN EXISTING GREASE INTERCEPTOR THAT THE NEW EQUIPMENT
WILL BE TIED INTO. THE EXISTING GREASE INTERCEPTOR HAS NOT BEEN IDENTIFIED AT THIS
TIME.
PANELS IN THE EXPANSION SUITES TO BE BACKFED FROM THE GREEN VALLEY MARKETPLACE
ELECTRICAL SERVICE. EXISTING ELECTRICAL SERVICE TO BE UPGRADED AS REQUIRED.
ARIUM IS WAITING ON CONFIRMATION FROM THE MANUFACTURER OF THE COMBI OVENS TO
CONFIRM THEY ARE SELF-VENTING AND DO NOT NEED TO BE LOCATED UNDER A HOOD. THE
TEST FIT SHOWS THE COMBI OVENS UNDER A HOOD PER THE ORIGINAL KITCHEN EQUIPMENT
DRAWINGS FOR THE B. GREEN KITCHEN PROJECT UNTIL INSTALLATION REQUIREMENTS HAVE
BEEN VERIFIED.
EXISTING METAL STUD WALLS WITHIN KITCHEN EXPANSION AREA TO RECEIVE LAYER OF NEW
MOLD RESISTANT GYPSUM BOARD.
PLAN
NORTH
0
2' 4'
SCALE 1/8" = 1' - 0"
EX. DOOR
LOCKED IN
PLACE
8'
TEMPERED
GLASS
EXTENT OF WORK
16'
CRITICAL DIMENSIONS SHALL NOT BE SCALED
EXISTING CONDITIONS HAVE BEEN PARTIALLY
FIELD VERIFIED BY ARIUM AE.
EX
FLOOR PLAN
ARCHITECTURAL
MORGAN STATE UNIVERSITY SA+P | 29
TITLE
TEST FIT PLAN
PROJECT FILE NAME: LATEST REVISION: ISSUE DATE:
ED95-GVMK-AC1 08 MAR 2024
SM: PM:
BY:
BAF KMM SR
2023 COPYRIGHT Arium AE, LLC BC1
DWG NO.
4 | TENANT FITOUT
NEW 60" COUNTER WITH SINK , TYP
FINISHES
(FOR PRICING PURPOSES ONLY)
LVT MANUFACTURER: SHAW CONTRACT
SERIES: UNCOMMON GROUND 4/0187V
COLOR PROVENCE 02140
LOCATION:
TYPICAL THROUGHOUT U.N.O.
FLR
SV
FLR
SV
FLR
CT
STAFF BREAK ROOM
MEDSPA
10'-0" x 9'-10"
OFFICE 3
10'-0" x 9'-10"
REF. BY
TENANT
LOCK
FLR
CT
FLR
SV
LOCK
15'-11" x 9'-11"
EXAM 6 EXAM 5 EXAM 4 EXAM 3 EXAM 2 EXAM 1
9'-10" x 10'
PHLEBOTOMY
8'-8" x 4'-0"
STORAGE
7'-8" x 2'-0"
FLR
SV
FLR
NURSES STATION
9'-1" x 8'-3"
FLR
SV
SV
PROCEDURE
15'-0" x 9'-1"
INFUSIONS / RECOVERY
OFFICE 1 ULTRASOUND
OFFICE 2
9'-0" x 9'-11"
FLR
SV
9'-10" x 10'
14'-9" x 5'-7"
NEW 7'-11" DEEP PLASTIC LAMINATE
TRANSACTION COUNTER AT 42" AFF, WITH
36" WIDE ADA DROP SECTION AT 34" AFF
FLR
CT
LOCK
9'-0" x 9'-11"
FLR
SV
FLR
SV
9'-10" x 10'
FLR
SV
NEW PARTITION FROM FLOOR TO
CEILING ABOVE, TYP.
FLR
SV
SUITE REAR DOOR;
CLOSER, LOCK
STOREROOM
LOCK
PRIVACY
LOCK
PRIVACY
FLR
9'-10" x 10'
RESTROOM
7'-8" x 8'-6"'
STORAGE
7'-8" x 6-11"
STAFF
RESTROOM
FT
FLR
SV
7'-8" x 7'-8"
FLR
SV
FLR
FT
FLR
SV
NEW PARTITION EXTENDING FROM DECK
TO DECK ABOVE
PUBLIC CORRIDOR
FLR
CT
FLR
CT
9'-10" x 10'
FLR
SV
9'-10" x 10'
NEW 6'-3" DEEP PLASTIC LAMINATE
TRANSACTION COUNTER AT 42" AFF,
WITH 36" WIDE ADA DROP SECTION
AT 34" AFF
VITALS
10'-11" x 4'-0"
CHECK-OUT
12'-1"x 6'-3"
CHECK-IN
9'-8" x 13'-5"
NEW ADJUSTABLE 5'-0"x18"
DISPLAY SHELVING
WAITING AREAS
13'-4" x 20'-1"
FLR
SV
FLR
SV
IT CLOSET
FLR
SV
ALL FURNITURE & EQUIP. BY
TENANT, TYP.
NEW 13'-6" DEEP PLASTIC
LAMINATE TRANSACTION
COUNTER AT 42" AFF, WITH
36" WIDE ADA DROP
SECTION AT 34" AFF
9'-0" x 3'-0"
SUITE ENTRY DOOR;
CLOSER, LOCK
SHEET VINYL (SV) MANUFACTURER: SHAW CONTRACT
SERIES:
TERASU REED 0797V
COLOR ZEN 96515
LOCATION:
VENIPUNCTURE, PROCEDURE
CARPET (CT) MANUFACTURER: PATCRAFT
SERIES: FLEX 10279
COLOR: FULCRUM 00501
LOCATION:
OFFICES, REMEPTION
NOTES:
MONOLITH
BASE MANUFACTURER: IOHNSONITE
TYPE:
4° COVE; 1/8* RUBBER
COLOR: BROWN 47
LOCATION:
TYPICAL THROUGHOUT U.N.O.
PAINT 1 MANUFACTURER: SHERWIN WILLIAMS
SERIES:
WHITE & PASTEL
COLOR:
PANDA WHITE / SW6147
LOCATION:
FIELD THROUGHOUT U.N.O.
PAINT 2 MANUFACTURER: SHERWIN WILLIAMS
SERIES:
HISTORIC
COLOR.
COLONIAL REVIVAL GRAY / SW2832
LOCATION:
RESTROOMS / ACCENT WALLS
CABINET /
COUNTER MANUFACTURER: WILSONART
TYPE:
LAMINATE
COLOR: WALNUT HEIGHTS 7965K-12
LOCATION:
NEW CABINETS / COUNTERTOPS
FLOOR TILE (FT) MANUFACTURER:
SHAW HARD SURFACE
SERIES,
TATTERED 12X24 TGS4A
COLOR: GRIGIO 00500
LOCATION:
RESTROOMS
WALL TILE MANUFACTURER: SHAW HARD SURFACE
SERIES:
BAKER STREET 4X16 TGL84
COLOR: WHITE 00100
LOCATION:
RESTROOMS; UP TO 48" AFF
GROUT 1 MANUFACTURER: CUSTOM
SERIES:
FUSION PRO
COLOR: WINTER GRAY 335
LOCATION:
@ FLOOR TILE
TEST FIT PLAN FOR:
VISIONARY WOMENS HEALTH
NOT FOR CONSTRUCTION
PER CLIENT DIRECTION ARIUM HAS NOT COMPLETED A FIELD SURVEY OF THE SPACE. THE PROPOSED DESIGN MAY CONFLICT WITH EXISTING CONDITIONS.
CHANGES TO THE DESIGN MAY BE REQUIRED DURING THE PREPARATION OF CONSTRUCTION DOCUMENTS OR DURING CONSTRUCTION DUE TO UNFORESEEN CONDITIONS.
SEE PROPOSAL FOR TERMS AND CONDITIONS.
0
2' 4'
SCALE 1/8" = 1' - 0"
CRITICAL DIMENSIONS SHALL NOT BE SCALED
8'
EXISTING CONDITIONS HAVE NOT BEEN FIELD VERIFIED BY
ARIUM AE.
16'
ARCHITECT / MEP ENGINEER:
GROUT 2 MANUFACTURER: CUSTOM
SERIES:
FUSION PRO
COLOR: SNOW WHITE 11
LOCATION:
@ WALL TILE
PROJECT:
COLUMBIA MEDICAL CAMPUS
5TH FLOOR
5500 KNOLL NORTH DRIVE
COLUMBIA, MD 21045
DWG: CC1
DATE: 02-02-24
FILE:
KN1-5VWH-BC1
BY: SM:
SR KLO
© 2024 A r i u m A E , L L C
30 |
MORGAN STATE UNIVERSITY SA+P | 31
4 | TENANT FITOUT
DESIGN DEVELOPMENT PLAN FOR:
VACANT
SUITE Q180
NOT FOR CONSTRUCTION
EX
EX
DESIGN DEVELOPMENT PLAN NOTES:
AN ARCHITECTURAL FIELD SURVEY OF THE SPACE HAS BEEN COMPLETED; AN MEP SURVEY HAS NOT YET BEEN COMPLETED. THE PROPOSED
DESIGN DOES NOT CONFLICT WITH VISIBLE ARCHITECTURAL CONDITIONS BUT MAY CONFLICT WITH HIDDEN CONDITIONS. CHANGES TO THE
DESIGN MAY BE REQUIRED DURING THE CREATION OF CONSTRUCTION DOCUMENTS OR DURING CONSTRUCTION DUE TO UNFORESEEN
CONDITIONS.
EX. VEST.
EX
EX. ELECTRICAL
ROOM
EX. OFFICE 1
11'-5" x 10'-5"
SOME ASSUMPTIONS WERE MADE IN PREPARING THIS DESIGN DEVELOPMENT PLAN. BEFORE APPROVING THIS DOCUMENT, THE TENANT
SHOULD CAREFULLY REVIEW BOTH THE DRAWINGS AND ALL NOTES WITH ADVISORS, VENDORS, AND OTHERS; TO BE SURE THAT THE
EXPRESSED DESIGN INTENT CONFORMS TO THE LAYOUT, FINISH, EQUIPMENT, TECHNICAL, AND OTHER NEEDS OF THE TENANT.
ALL DIMENSIONS ARE APPROXIMATE AND SHOULD NOT BE USED BY ANY PARTY TO ORDER FURNISHINGS, MILLWORK, OR EQUIPMENT.
EX
GYPSUM
BULKHEAD
EX
EX
NEW HANDICAPPED RESTROOMS WILL RECEIVE ADA COMPLIANT FIXTURES INCLUDING WATER CLOSET, WALL HUNG SINK WITH MIRROR,TOILET
PAPER DISPENSER, SOAP DISPENSER, PAPER TOWEL DISPENSER AND GRAB BARS.
THERE WILL BE NO NEW FLOORING, BASE OR PAINT FINISH FOR THIS SCOPE OF WORK. GC TO PRIME NEW WALLS AND MAKE PAINT READY.
IN AREA OF WORK, EXISTING CEILING GRID AND PANELS WILL REMAIN. DAMAGED AND MISSING COMPONENTS WILL BE REPLACED. NEW
COMPONENTS SHALL MATCH EXISTING. THE REMAINING CEILING CONDITIONS SHALL REMAIN AS IS THROUGHOUT THE SUITE.
EX. OFFICE 3
34'-9" x 14'
EX. OFFICE 2
16'-1" x 13'-6"
EXISTING GYPSUM
BULKHEAD TO
REMAIN, TYP.
GC TO REMOVE ALL GLUE AND ADHESIVES FROM TOILET ROOM FLOORS. MAKE ROOM READY. NEW TOILET SHALL BE INSTALLED ON NEWLY PREPARED
FLOOR.
NEW DOORS SHALL BE PAINT GRADE. ALL NEW DOORS, FRAMES, AND HARDWARE WITHIN SUITE WILL BE SUITE STANDARD AND MATCH
EXISTING DOOR SIZE AND FINISH OF UNITS SCHEDULED TO REMAIN. (MINIMUM WIDTH OF 36" AND MINIMUM HEIGHT OF 80".)
BOTH NEW DOORS SHALL RECEIVE NEW ADA COMPLIANT LEVER STYLE PRIVACY HARDWARE WITH INDICATOR.
EXISTING BUILDING STANDARD MINI-BLINDS TO REMAIN.
IN AREA OF WORK, EXISTING LIGHTS WILL BE REUSED AND RELOCATED. CLEAN AND RELAMP. REPAIR OR REPLACE ANY BROKEN OR MISSING
COMPONENTS. NEW COMPONENTS SHALL MATCH EXISTING.
EXISTING
PARTITION TO
REMAIN, TYP.
EX
EX
EXISTING GYPSUM
BULKHEAD TO
REMAIN, TYP.
EX. CLOSET
EX
NEW PARTITION FROM FLOOR TO THE
UNDERSIDE OF CEILING W/ SOUND BATT
INSULATION
EX. OPEN
OFFICE
EX
IN AREA OF WORK , EXISTING ELECTRICAL AND DATA/ TELEPHONE OUTLETS SHALL BE REMOVED AND RELOCATED. THE REMAINING EXISTING
ELECTRICAL AND DATA/ TELEPHONE OUTLETS CONDITIONS SHALL REMAIN THROUGHOUT THE SUITE.
CONTRACTOR SHALL MODIFY LIGHTING, SWITCHING, AND HVAC TO REFLECT NEW PLAN. SPRINKLER, FIRE DETECTION, AND FIRE ALARM WORK
WILL BE DONE ON A DESIGN BUILD BASIS BY A CONTRACTOR HIRED VENDOR. THESE VENDORS WILL OBTAIN THEIR OWN PERMITS BY
PRODUCING THEIR OWN CODE CONFORMING DESIGN USING THEIR OWN STAMPED AND SIGNED DRAWINGS.
EX. OFFICE 4
10'-2" x 11'-8"
EXISTING
DOOR TO
REMAIN, TYP.
WOMENS
RESTROOM
MENS
RESTROOM
HATCH: AREA OF FLOORING TO BE
REMOVED, SEE NOTES.
AREA OF WORK
0
2' 4'
SCALE 1/8" = 1' - 0"
8'
16'
CRITICAL DIMENSIONS SHALL NOT BE SCALED
EXISTING CONDITIONS HAVE BEEN PARTIALLY
FIELD VERIFIED BY ARIUM AE.
ARCHITECT / MEP ENGINEER:
PROJECT:
VACANT SUITE Q180
LOWER LEVEL
10005 OLD COLUMBIA ROAD
COLUMBIA MD, 21046
DWG:
AL1
DATE: 08 MAR 2024
FILE:
OCO5-LLRR-AL1
BY: SM:
SR DM
© 2024 Arium AE, LLC
32 |
MORGAN STATE UNIVERSITY SA+P | 33
EX
EX
EX
EX
EX
EX
EX
c
4 | CONSTRUCTION DOCUMENTATION
MAR 2023
CONSTRUCTION DOCUMENTS FOR:
33215 ROOM CONVERSION
6595 SPRINGFIELD CENTER DRIVE
SPRINGFIELD, VA 22150
PROJECT MANAGER:
JBG SMITH
6595 SPRINGFIELD CENTER DRIVE
SPRINGFIELD, VA 22150
PHONE:571-444-0323
STANDARD FINISH & EQUIPMENT SCHEDULE
THE WORK OF THIS CONTRACT ENCOMPASSES THE CONSTRUCTION OF A FULLY FINISHED PROJECT.
AS SUCH, UNLESS NOTED SPECIFICALLY IN THE PLANS, THE CONTRACTOR SHALL ASSUME THAT ALL
AREAS WITHIN THE PROJECT EXTENTS, OR CONSTRUCTION INCLUDED IN THIS CONTRACT WILL BE
EITHER BUILT IN ACCORDANCE WITH THE FOLLOWING STANDARDS OR BUILT IN ACCORDANCE WITH
ONE OF THE ALTERNATE STANDARDS NOTED IN THE PLANS.
FLOOR FINISHES
CS
EX
CARPET STANDARD:
MATCH BUILDING STANDARD. COLOR: 85% MILLIKEN, LINEATION, TGP118-165 SHELL BROWN;
15% MILLIKEN, TSA HQ CUSTOM LINEATION, TGP118-165 SHELL BROWN (MK2SFT168
CHARTREUSE)
EXISTING FLOOR FINISH TO REMAIN:
CLEAN AND PROTECT DURING CONSTRUCTION.
NOTE:
ALL FLOOR FINISHES IN AREAS OF WORK, PER IBC 804.4.2, SHALL MEET CLASS II FOR SPRINKLERED
BUILDINGS. SMOKE DEVELOPMENT SHALL NOT EXCEED 450.
ALL TRANSITIONS FROM VCT TO CARPET SHALL HAVE VINYL TRANSITION STRIP; CONTRACTOR TO
SELECT APPROPRIATE ADAPTOR SIZE FOR THE DIMENSIONAL THICKNESS OF THE FLOOR MATERIALS;
TARKETT/JOHNSONITE, COLOR: TO BE SELECTED, UNLESS NOTED OTHERWISE.
ALL TRANSITIONS SHALL OCCUR AT THE CENTERLINE OF THE DOOR, UNLESS NOTED OTHERWISE, AND
SHALL BE ADA COMPLIANT.
BASE FINISHES
RB RESILIENT WALL BASE:
MATCH BUILDING STANDARD. COLOR: JOHNSONITE, #08, SIZE 2 1/2", COLOR: ICICLE, BASE TO BE
COVE AT HARD SURFACES AND STRAIGHT AT SOFT SURFACES
EX EXISTING BASE TO REMAIN
PARTITION FINISHES
PE WALL PAINT, EGG-SHELL FINISH:
SHERWIN WILLIAMS, EGG-SHELL FINISH; COLOR: BENJAMIN MOORE OC-152 SUPER WHITE
EX EXISTING WALL FINISH TO REMAIN
NOTE:
ALL WALL FINISHES IN AREAS OF WORK, PER IBC TABLE 803.13, SHALL MEET CLASS C FOR
SPRINKLERED BUILDINGS. SMOKE DEVELOPMENT SHALL NOT EXCEED 450.
CEILING FINISHES
A CEILING SYSTEM:
BUILDING STANDARD ARMSTRONG, WHITE ULTIMA HIGH NRC TEGULAR, 24X24, WHITE
SUPRAFINE XL 9/16” EXPOSED TEE GRID, UNLESS NOTED OTHERWISE.
EX
BASE FIN. [?]
FLOOR FIN. [?]
EXISTING CEILING TO REMAIN:
REPLACE DAMAGED AND MISSING COMPONENTS WITH NEW COMPONENTS. NEW COMPONENTS
TO MATCH EXISTING. ENTIRE CEILING SHALL BE "LIKE NEW" IN APPEARANCE.
CEILING HEIGHT: MAINTAIN EXISTING
WALL FIN. [?]
CEILING FIN. [?]
NOTE:
ALL CEILING FINISHES IN AREAS OF WORK, PER IBC TABLE 803.13, SHALL MEET CLASS C FOR
SPRINKLERED BUILDINGS. SMOKE DEVELOPMENT SHALL NOT EXCEED 450.
34 |
FLR BAS WAL CLG
? ? ? ?
DOORS AND FRAMES
SEE DOOR SCHEDULE
WOOD DOORS IN TENANT SUITE:
MATCH SUITE STANDARD
NOTE: ALL DOORS TO BE 4" FROM ADJACENT WALL U.N.O.
ARCHITECT / MEP ENGINEER:
ARIUM AE, LLC
5537 TWIN KNOLLS ROAD
SUITE 435
COLUMBIA, MARYLAND 21045
PHONE WASHINGTON: 301-621-4600
PHONE BALTIMORE: 410-730-2300
FAX: 410-730-2796
HARDWARE
HIGH SECURITY LOCKSET, X-10:
LM10K TYPE IV, KABA-MAS X-10 WITH PANIC BAR; LKM10KPX10, TO MEET FF-L-2890C
STANDARDS.
POWER ASSIST OPERATOR (FOR USE AT DOORS EXCEEDING ADA FORCE REQUIREMENTS):
FALCON, 8200 SERIES, OR MATCH BUILDING STANDARD.
HINGES:
NRP HINGES, FINISH TO MATCH LATCHSET OF DOOR
POWER TRANSFER HINGE:
MCKINNEY ELECTROLYNX HINGE OR PM APPROVED EQUAL AS REQUIRED BY DOOR TYPE.
DOOR SEALS:
INTEGRAL TO STC-50 DOOR AND FRAME ASSEMBLY.
RECESSED AUTOMATIC DOOR DROP:
INTEGRAL TO STC-50 DOOR AND FRAME ASSEMBLY.
ALUMINUM THRESHOLD:
NATIONAL GUARD PRODUCTS INC, ADA COMPLIANT, WITHOUT RIDGES OR GROOVES, FINISH TO
MATCH LATCHSET OF DOOR.
CARD READER: BY TENANT
BYPASS DOOR HARDWARE:
COMMERCIAL GRADE SLIDING DOOR HARDWARE SET, JOHNSON HARDWARE, 134F SERIES, 1125
BALL BEARING WHEEL HANGERS W/ ADA COMPLIANT RECESSED PULLS, HARDWARE INCLUDED;
OR PM APPROVED EQUAL.
FLOOR STOPS (ALL DOORS):
FLOOR MOUNTED WHERE ALLOWABLE; SSIMILAR OR EQUAL TO IVES FS438.
HARDWARE FINISH:
MATCH SUITE STANDARD
NOTE:
FOR KEYING REQUIREMENTS, SEE DOOR SCHEDULE.
FINISHES
DOOR FINISH : SEE DOORS AND FRAMES
PAINTED DOORS SHALL BE PAINTED SHERWIN WILLIAMS, SEMI-GLOSS; COLOR: BENJAMIN MOORE
OC-152 SUPER WHITE.
DOOR FRAME AND TRIM FINISH :
PAINT, SHERWIN WILLIAMS, SEMI-GLOSS; COLOR: BENJAMIN MOORE OC-152 SUPER WHITE.
FURNISHINGS
FLAT PANEL TV(S):
BY TENANT. G.C. TO PROVIDE ALL NECESSARY IN-WALL BLOCKING. COORDINATE FINAL
LOCATION WITH TENANT.
CEILING PROJECTOR AND MOUNT:
PROVIDED BY TENANT, INSTALLED BY CONTRACTOR
AUTOMATIC OVERHEAD PROJECTION SCREEN:
DA-LITE, ADVANTAGE DELUX ELECTROL, AUTOMATIC ELECTRIC PROJECTION SCREEN, (7'HX9'W),
TYPE 1 & 2, MATT WHITE. FINISH TO MATCH ADJACENT SUSPENDED CEILING.
ELECTRICAL
ELECTRICAL DEVICES:
REFER TO ELECTRICAL DRAWINGS FOR ELECTRICAL DEVICE SPECIFICATIONS. ELECTRICAL
DEVICES (OUTLETS, SWITCHES, ETC.): COLOR: MATCH EXISTING SUITE/BUILDING STANDARD
DEVICES. COVER PLATES (OUTLETS, SWITCHES, ETC): MATCH EXISTING SUITE/BUILDING
STANDARD
LIGHT FIXTURES:
SEE ELECTRICAL DRAWING
SEE ELEC DRAWINGS.
SPRINKLERS
SPRINKLER HEADS IN SUITE:
MATCH BUILDING STANDARD
SEE MECH DRAWINGS.
DOOR MARK SCHEDULE
NOTES:
SEE STANDARD FINISH AND EQUIPMENT SCHEDULE AND SPECIFICATIONS FOR DOOR AND FRAME
FINISHES, HARDWARE, AS WELL AS SPECIES, STAIN, AND FINISH OF WOOD VENEER DOORS.
SEE SHEET T3 FOR DOOR LEGEND.
ALL DOORS TO RECEIVE WALL STOPS WHERE ALLOWABLE. SEE SPECIFICATIONS.
THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING THE HEIGHT OF ANY EXISTING DOORS IN THIS
SPACE AND NOTIFYING THE PROJECT REPRESENTATIVE OF ANY DISCREPANCY BETWEEN THE
EXISTING CONDITION AND THE SIZE, STYLE, MATERIAL AND/OR FINISH OF THE NEW DOORS NOTED ON
THIS SCHEDULE.
KEY TO EXISTING BUILDING MASTER, COORDINATE FINAL KEYING REQUIREMENTS WITH PROJECT
MANAGER.
LEGEND
DOOR
MARK ROOM SIZE TYPE STC/ RF TYPE
NUMBER W HT
1
2
DOOR SCHEDULE
DOOR TYPE [WS]
WS/PA
HARDWARE NOTES
3J37W (2) 3'-0" 8'-10" S50 STC-50 HL -
3J37W 3'-0" 8'-10" SL - BP -
HARDWARE TYPE [PA]
STANDARD HARDWARE TYPES:
EX EXISTING HARDWARE TO REMAIN. IF LOCKSET, REKEY LOCK TO MATCH NEW MASTER.
BP BYPASS DOOR HARDWARE & TRACK SYSTEM WITH ADA COMPLIANT RECESSED PULLS.
HL HIGH SECURITY LOCKSET AT STC DOOR; LKM LEVER STYLE ELECTRIFIED LOCKSET WITH X-10,
CARD READER BY TENANT, POWER TRANSFER HINGE, AUTOMATIC DOOR CLOSER. CAM-LIFT
HINGES, DOOR SEALS, AUTOMATIC DOOR DROP, AND THRESHOLD PROVIDED AS PART OF
ACOUSTIC DOOR ASSEMBLY. DOORS SHALL ALWAYS BE OPERABLE IN THE DIRECTION OF
EGRESS. NOTE: CONTRACTOR SHALL ADJUST CLOSER UNTIL MEASURED FORCE REQUIRED TO
FULLY OPEN DOOR IN FIELD DOES NOT EXCEED 15 LBF TO RELEASE THE LATCH, 30 LBF TO SET
THE LEAF IN MOTION, AND 15 LBF TO OPEN THE LEAF TO THE FULL MINIMUM REQUIRED WIDTH.
KEY PLAN
NOT TO SCALE
A
A.3
A.5
B
B.8
C
D
D.2
E
E.7
F
STANDARD DOOR TYPES:
EX
SL
EXISTING DOOR
19.9
16.7
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16.3 16 15 14 13 12 11 10.8 10 9 8 7 6 5 4 3 2 1
AREA OF WORK
EXISTING DOOR, FRAME, AND HARDWARE TO REMAIN; UNLESS NOTED OTHERWISE
BYPASS SLIDING DOORS
ITEM: NEW PAIR OF 72"X1-3/4"X[84" OR SUITE STANDARD HEIGHT], FLUSH, SOLID CORE, PAINT
GRADE, BYPASS PAIR OF SLIDING DOORS; TO MATCH PROJECT STANDARD.
MANUFACTURER: GENERIC (SEE NOTES ABOVE)
DOOR FRAME: GYPSUM BOARD CASED OPENING.
STC DOORS:
S50 ACOUSTICAL METAL DOOR - TO MEET STC 50
ITEM: NEW 36"x1-7/8"x106", FLUSH, METAL ACOUSTICAL DOOR TO MATCH PROJECT STANDARD.
PROVIDE DOOR AND FRAME ASSEMBLIES. ASSEMBLY TO INCLUDE MANUFACTURER SUPPLIED
COMPRESSION PERIMETER SEALS, DOOR BOTTOM, AND THRESHOLD AS REQUIRED TO MEET
THE SPECIFIED STC RATING. PROVIDE HEAVY DUTY DOOR CLOSER AS RECOMMENDED FOR USE
WITH THIS DOOR SYSTEM.
MANUFACTURER: OVERLY MODEL 509575 (SEE NOTES ABOVE)
DOOR FRAME: OVERLY; GC TO CONFIRM REQUIRED JAMB SIZE PRIOR TO ORDERING. FRAME TO
BE GROUTED AT JAMB.
MECHANICAL
M1
M2
M3
NOT TO SCALE
W
DRAWING INDEX
ARCHITECTURAL
T1
T2
T3
T4
T5
ELECTRICAL
E1
E2
E3
E4
TITLE SHEET
SPECIFICATIONS
DRAWINGS STANDARDS AND DETAILS
EGRESS PLAN
FLOOR PLANS
COVER SHEET - MECHANICAL
FLOOR PLANS - MECHANICAL
DETAILS - MECHANICAL
COVER SHEET - ELECTRICAL
FLOOR PLANS - NEW WORK - ELECTRICAL
ELECTRICAL RISER DIAGRAM & SCHEDULES
ELECTRICAL SCHEDULES
LOCATION MAP
NORTH
CODE DATA
BUILDING ADDRESS:
JURISDICTION:
APPLICABLE CODES:
USE GROUP:
TYPE OF CONSTRUCTION:
NO. OF STORIES:
HIGH RISE:
COVERED MALL:
FULLY SUPPRESSED:
FIRE ALARM:
VOICE EVACUATION SYSTEM:
GROSS FLOOR AREA:
APPROXIMATE AREA OF OCCUPANCY:
APPROXIMATE AREA OF
SUBSTANTIVE ALTERATION:
SEE SHEET T4 FOR OCCUPANT CALCULATIONS.
6595 SPRINGFIELD CENTER DRIVE
SPRINGFIELD, VA 22150
FAIRFAX COUNTY
2021 VIRGINIA CONSTRUCTION CODE, PART I
2021 VIRGINIA ENERGY CONSERVATION CODE
2021 VIRGINIA MECHANICAL CODE
2021 VIRGINIA PLUMBING CODE
2021 VIRGINIA FUEL GAS CODE
2020 NATIONAL ELECTRICAL CODE
2021 VIRGINIA EXISTING BUILDING CODE,
PART II
2021 VIRGINIA FIRE PREVENTION CODE
FAIRFAX AMENDMENTS TO CHAPTER 62
2017 ACCESSIBLE AND USABLE BUILDINGS
AND FACILITIES
EXISTING
BUILDING
B
9
70,055 SQ.FT
70,055 SQ.FT.
290 SQ.FT.
PROPOSED
ALTERATION
B
GENERAL PROJECT SCOPE DESCRIPTION:
RECONFIGURATION OF EXISTING STORAGE SPACE TO CONFERENCE ROOM.
EXISTING PARTITIONS AND DOOR TO BE UPGRADED / REPLACED WITH STC-50
ASSEMBLIES. EXISTING WASHER/DRYER AND EYEWASH STATION TO REMAIN.
MECHANICAL AND ELECTRICAL SCOPE AS REQUIRED FOR CHANGE IN USE.
THERE IS NO STRUCTURAL SCOPE AS A PART OF THIS PROJECT
SPRINKLER, FIRE DETECTION, AND FIRE ALARM WORK WILL BE DONE ON A
DESIGN BUILD BASIS BY THE CONTRACTOR HIRED VENDOR. THESE VENDORS
WILL OBTAIN THEIR OWN PERMITS BY PRODUCING THEIR OWN CODE
CONFORMING DESIGN USING THEIR OWN STAMPED AND SIGNED DRAWINGS.
-B
YES
NO
YES
YES
YES
9
-B
YES
NO
YES
YES
YES
FIRE RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS
(FROM ORGINAL BUILDING PERMIT SET)
RATING UL NUMBER
FLOOR / CEILING:
1 HR UL D902
ROOF / CEILING:
1 HR P 819
COLUMNS:
1 HR UL X 528
BEAMS:
1 HR UL D902
CORRIDOR SEPARATION:
0 HR N/A
TENANT SEPARATION WALLS:
0 HR N/A
MORGAN STATE UNIVERSITY SA+P | 35
ARCHITECT / MEP ENGINEER: CONTRACTOR:
REV. NO. DATE
DESCRIPTION
PROJECT MANAGER:
JBG SMITH
6596 SPRINGFIELD CENTER DRIVE
SPRINGFIELD .VA 22150
571-444-0323
PROJECT:
33215 ROOM CONVERSION
3RD FLOOR
6595 SPRINGFIELD CENTER DRIVE
SPRINGFIELD, VA 22150
DWG NO.
TITLE
LATEST REVISION: ISSUE DATE:
T1
PROJECT FILE SP95-3CCR NAME: -ZT1
SM: PM:
BY:
SBN KLO SR
2024 COPYRIGHT Arium AE, LLC ISSUED FOR 100% REVIEW - DATE: 04-05-2024 - NOT FOR CONSTRUCTION
SPECIFICATIONS:
THE FOLLOWING SPECIFICATIONS ARE GENERIC AND NOT TO BE TAKEN AS PROJECT EXCLUSIVE.
SPECIFICATION SECTIONS FOR WORK NOT INCLUDED IN THIS PROJECT SHOULD BE DISREGARDED.
00100 INSTRUCTIONS TO BIDDERS
1. THE PROJECT MANAGER (PM) REFERRED TO IN THE ACCOMPANYING DOCUMENTS IS THE OWNERS
DESIGNATED REPRESENTATIVE. THE PRIMARY RESPONSIBILITY FOR ADMINISTRATION OF THE
BIDDING AND CONSTRUCTION PROCESS WILL BE HELD BY THE PROJECT MANAGER. QUESTIONS
CONCERNING THE PROJECT SHOULD BE REFERRED TO THE PROJECT MANAGER'S DESIGNATED
REPRESENTATIVE FOR WRITTEN CLARIFICATION. OPINIONS NOT OBTAINED IN WRITING OR
OBTAINED FROM A SOURCE OTHER THAN THE PROJECT MANAGER'S REPRESENTATIVE ARE NOT TO
BE CONSIDERED FINAL UNTIL VERIFIED IN WRITING BY THE PROJECT MANAGER. WHEN THE PROJECT
MANAGER ACTS AS A CONSTRUCTION MANAGER OR GENERAL CONTRACTOR, ALL REFERENCES TO
"CONTRACTOR" IN THESE DOCUMENTS WILL BE TAKEN TO MEAN ALL CONTRACTORS AND
SUBCONTRACTORS HIRED DIRECTLY BY THE PROJECT MANAGER TO UNDERTAKE A PARTICULAR
AREA OF WORK.
2. THE DRAWINGS IN THIS DOCUMENT SET EXPRESS THE ARCHITECTURAL DESIGN INTENT FOR THE
PROJECT. UNLESS ACCOMPANIED BY DRAWINGS SEALED BY A REGISTERED ENGINEER WITH A
REGISTRATION IN THE JURISDICTION OF THE PROJECT, ALL REFERENCES TO MECHANICAL,
ELECTRICAL, STRUCTURAL, OR CIVIL ENGINEERING MATTERS ON THE ARCHITECT'S DRAWING ARE
TO BE CONSIDERED INFORMATIONAL TO THE CONTRACTOR. IF NO SEALED ENGINEERING DRAWINGS
ACCOMPANY THIS SET, THE RESPONSIBILITY FOR OBTAINING ENGINEERING DESIGN AS MAY BE
REQUIRED UNDER THE LAWS OF THE PROJECT JURISDICTION WILL BE HELD BY THE CONTRACTOR
UNDERTAKING THE PROJECT. BECAUSE OF THE LIMITED TIME AND OTHER RESOURCES AVAILABLE
TO PREPARE THESE DOCUMENTS, THE ARCHITECT HAS LIMITED KNOWLEDGE OF THE WORK OF
OTHER DISCIPLINES (MECHANICAL, ELECTRICAL, STRUCTURAL, SITE, CIVIL, AND OTHERS).
CONTRACTOR WILL CAREFULLY REVIEW AND COORDINATE THE WORK SHOWN ON OTHER DRAWINGS
AND INFORMATION FROM SUBCONTRACTORS TO INSURE A COMPLETE ALL INCLUSIVE BID.
3. THE WORK PERFORMED UNDER THIS CONTRACT WILL FOLLOW THE INTENT OF THE DESIGN
DRAWINGS, THE RECOMMENDATIONS OF THE PRODUCT MANUFACTURER FOR INSTALLATION OF HIS
PRODUCT, AND WILL INCLUDE ALL LABOR, MATERIALS (UNLESS OTHERWISE NOTED), PERMITS
(INCLUDING ALL SUBCONTRACTOR PERMITS), EQUIPMENT, AND ENGINEERING REQUIRED BY THE
CONTRACTOR TO PRODUCE A SAFE, HIGH QUALITY PROJECT READY FOR USE BY THE PUBLIC,
MEETING ALL CODES AND ORDINANCES, AND COMPLYING WITH THE HIGHEST STANDARDS OF
QUALITY FOR THE INDUSTRY. OBTAIN ALL MAJOR COMPONENT SYSTEMS FROM SINGLE SOURCE
SUPPLIERS WITH MANUFACTURER APPROVED INSTALLATION CONTRACTORS.
4. BEFORE SUBMITTING A BID, CONTRACTORS SHOULD VISIT THE SITE TO VERIFY ALL DIMENSIONS
AND ACQUAINT THEMSELVES WITH ALL CONDITIONS THAT MAY AFFECT THE PERFORMANCE OF
THEIR WORK. CONTRACTOR SHOULD DETERMINE THE CURRENT AVAILABILITY FOR DELIVERY OF ALL
SPECIFIED MATERIALS. PRODUCT SUBSTITUTIONS ARE PERMITTED FOR PRODUCT OF EQUAL
QUALITY AT THE SOLE DISCRETION OF THE PROJECT MANAGER IN CONSULTATION WITH THE
ARCHITECT. WRITTEN APPROVAL OF SUBSTITUTIONS MUST BE OBTAINED PRIOR TO ANY BID
SUBMISSIONS. THE CONTRACTOR WILL COORDINATE THE WORK OF ALL TRADES UNDERTAKING
WORK UNDER THIS CONTRACT. ALONG WITH THE CONTRACTOR'S PROPOSAL, THE CONTRACTOR
WILL NOTIFY THE PROJECT MANAGER OF ANY MATERIALS THAT CANNOT BE READILY OBTAINED,
LIMITATIONS ON SCHEDULE OR OTHER AREAS OF PERFORMANCE THAT MUST BE ADHERED TO BY
ANY OTHER PARTY WORKING ON THE PROJECT, BUT NOT UNDER THE DIRECT CONTROL OF THE
CONTRACTOR. BEFORE BIDDING, CONTRACTORS SHOULD SEEK WRITTEN CLARIFICATION OF ANY
NOTED CONFLICTS, AREAS OF CONFUSION, DISCREPANCIES, OR OTHER VISIBLE OR KNOWN
PROBLEMS THAT MAY AFFECT THE PERFORMANCE OR COMPLETION OF THE WORK. QUESTIONS
NORMALLY COVERED UNDER THE GENERAL OR SUPPLEMENTARY CONDITIONS OF A CONTRACT (IE:
SCHEDULE, USE OF BUILDING UTILITIES, STAGING OF THE PROJECT, ETC.) WILL BE ADDRESSED TO
THE PROJECT MANAGER FOR WRITTEN CLARIFICATION PRIOR TO BIDDING. CONTRACTOR SHALL
INSURE THAT ALL SUBCONTRACTORS ARE AWARE OF THE FULL REQUIREMENTS OF THE PROJECT.
COORDINATION OF THE PROJECT TO ACHIEVE THE REQUIRED FINISHED CONDITION IS THE
RESPONSIBILITY OF THE CONTRACTOR. ANY WORK NOT UNDERTAKEN BY A SUBCONTRACTOR WILL
BE THE RESPONSIBILITY OF THE CONTRACTOR. SUBMISSION OF A BID WILL INDICATE THAT THE
CONTRACTOR HAS UNDERTAKEN ALL OF THE ABOVE INVESTIGATIONS AS WELL AS THOROUGHLY
REVIEWING THE DRAWINGS AND IS WILLING TO UNDERTAKE THE PROJECT WITH THE
UNDERSTANDING THAT NO CLAIMS FOR EXTRA PAYMENT, MORE TIME OR A DECREASE IN THE
SPECIFIED LEVEL OF QUALITY WILL BE PERMITTED BY THE PROJECT MANAGER OR OWNER IF ANY OF
THE ABOVE WAS NOT DONE.
5. WHERE CONFLICTS BETWEEN ELEMENTS OF THE DRAWINGS, SPECIFICATIONS, DIMENSIONS,
FIELD CONDITIONS, OWNER OR TENANT PROVIDED DATA, OR OTHER SOURCES OF PROJECT
INFORMATION ARE FOUND, THE CONTRACTOR SHOULD OBTAIN WRITTEN CLARIFICATION FROM THE
PM BEFORE BIDDING OR ASSUME THAT THE MORE STRINGENT INTERPRETATION OF THE SITUATION
WILL PREVAIL.
6. ALL WORK SHALL TAKE PLACE AS DEFINED BY BUILDING RULES AND REGULATIONS UNLESS
OTHERWISE DIRECTED BY PROJECT MANAGER.
7.GC SHALL PROVIDE 3-4 CONTACTS FOR P.I.V CARD ACCESS AT TIME OF BID.
8. ACCESS TO OFFICES/ WORK AREAS OUTSIDE THE AREA OF WORK SHALL BE MAINTAINED AT ALL
TIMES.
00200 GENERAL NOTES:
1. UNLESS SPECIFICALLY NOTED AS THE WORK OF OTHERS, THIS CONTRACT WILL INCLUDE FULLY
FINISHING ALL BUILT AREAS WITHIN THE LIMITS OF THE GENERAL EXTENT OF CONTRACT WITH
STANDARD FINISHES AND CODE COMPLYING SYSTEMS INCLUDING:
FLOOR FINISH, BASE, WALL AND CEILING FINISH, DOORS, FRAMES, HARDWARE, PLUMBING, WASTE,
VENT, HOT AND COLD WATER, H.V.A.C.,LIGHTING, POWER, AND FIRE PROTECTION AND DETECTION
SYSTEMS. THIS WORK WILL FULLY COMPLY WITH ALL APPLICABLE CODES, ORDINANCES, AND LAWS.
THE PRODUCT OF THE CONSTRUCTION CONTRACT WILL BE A FULLY OCCUPIABLE, LIKE-NEW
FACILITY, FINISHED IN A PROFESSIONAL MANNER, AND MEETING THE HIGHEST INDUSTRY
STANDARDS. CONTRACTOR WILL OBTAIN ALL REQUIRED PERMITS INCLUDING USE AND
OCCUPANCY PERMIT.
2. REFERENCES TO MECHANICAL, ELECTRICAL, STRUCTURAL AND OTHER ITEMS NORMALLY
UNDERTAKEN BY PROFESSIONAL ENGINEERS, SHOWN ON THE ARCHITECTURAL DOCUMENTS
INDICATE ONLY A SCHEMATIC OUTLINE OF THE REQUIRED SYSTEM. CONTRACTOR SHOULD
REFERENCE THE WORK OF A PROFESSIONAL ENGINEER FOR DETAILED DESCRIPTIONS OF THIS
WORK. ENGINEERING OF COMPONENTS NOT PROVIDED BY THE PM WILL BE BY A PROFESSIONAL
ENGINEER LICENSED TO PRACTICE IN THE JURISDICTION OF THE PROJECT. PROVIDE SEALED
DRAWINGS & CALCULATIONS SATISFACTORY TO THE PM.
3. THE LIMITED ARCHITECTURAL DOCUMENTS THAT MAKE UP THIS DRAWING SET SHOULD ONLY BE
IMPLEMENTED BY CONTRACTORS KNOWLEDGEABLE IN THE INTERPRETATION OF SUCH DOCUMENTS.
ITEMS WHICH ARE NOT CLEAR, SHOULD BE REFERRED TO THE ARCHITECT OR PROJECT MANAGER
FOR CLARIFICATION. THE ARCHITECT IS NOT RESPONSIBLE FOR CONSTRUCTION INSPECTION. THE
ARCHITECT'S LIABILITY IS LIMITED TO THE VALUE OF HIS CONTRACT.
4. ALL NOTIFICATION REQUIRED UNDER THIS CONTRACT SHALL BE WRITTEN AND DELIVERED
IMMEDIATELY. TRANSMISSION WILL BE VIA A FAX WITH A CONFIRMED RECEIPT RETAINED AS
EVIDENCE OF TRANSMISSION OR VIA CERTIFIED MAIL WITH RETURN RECEIPT HELD BY THE SENDER.
5. THE DRAWINGS DO NOT ANTICIPATE ANY HAZARDOUS OR TOXIC MATERIALS IN EITHER EXISTING
OR NEW WORK. IF THE CONTRACTOR BECOMES AWARE OF ANY SUCH MATERIALS, HE WILL
IMMEDIATELY GIVE WRITTEN NOTICE BY CERTIFIED MAIL TO BOTH THE ARCHITECT AND THE PM.
6. UNLESS OTHERWISE NOTED, REFERENCE TO ANY CODES, STANDARDS, MANUFACTURER'S DATA
OR OTHER CRITERIA WILL BE ASSUMED TO BE THE MOST CURRENT EDITION AVAILABLE AT THE DATE
OF ISSUE OF THE CONTRACT DOCUMENTS.
7. WHERE CONFLICTS IN THESE DOCUMENTS EXIST THE FOLLOWING SHALL BE THE ORDER OF
PRECEDENCE FOR THIS WORK: A. CODE OR OTHER LEGAL REQUIREMENTS, B. OWNER-CONTRACTOR
AGREEMENT, C. THESE DOCUMENTS. NOTE THAT ALL WORK IS "UNLESS OTHERWISE NOTED."
IDENTIFIED CONFLICTS WILL BE ADJUSTED TO THE BENEFIT OF THE OWNER. ALL SUCH CONFLICTS
SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT.
00300 CONSTRUCTION NOTES:
1. RATED PARTITIONS ARE TO BE CONSTRUCTED AS COMPLETE CLOSURES IN COMPLIANCE WITH
THE TESTED ASSEMBLY THAT WAS THE BASIS FOR THE RATING. ALL PENETRATIONS SHOULD BE
SEALED AND FIRE DAMPERS PROVIDED AS REQUIRED.
2. DO NOT CUT STRUCTURAL MEMBERS DURING DEMOLITION, CORE DRILLING, OR OTHER PHASES
OF CONSTRUCTION WITHOUT OBTAINING PM WRITTEN APPROVAL.
3. ALL PRODUCTS (OR SYSTEMS) INCLUDED IN THIS WORK WILL BE INSTALLED TO STRICTLY
CONFORM WITH THE PRODUCT MANUFACTURER'S RECOMMENDATIONS. CONTRACTOR WILL
CONFIRM CURRENT APPLICABILITY OF THE SPECIFIED PRODUCT FOR THE INTENDED USE WITH THE
PRODUCT MANUFACTURER. IF THE MANUFACTURER INDICATES THAT THE INTENDED USE IS AN
INAPPROPRIATE USE OF THE PRODUCT, OR IF THERE ARE ANY LIMITATIONS ON THE USE OF THE
PRODUCT, THE CONTRACTOR WILL NOTIFY THE PM.
4. PROVIDE FLUSH, LOCKED, AND RATED (IF REQUIRED), ACCESS DOORS TO ALL VALVES, DAMPERS,
AND OTHER CONCEALED OPERABLE ITEMS WHEREVER THEY ARE FOUND IN THE PROJECT.
CONSULT THE MECHANICAL AND ELECTRICAL DOCUMENTS, MATERIAL SUPPLIERS AND
SUBCONTRACTORS FOR THE REQUIRED ACCESS DOOR LOCATIONS AND SIZES.
5. STRUCTURAL COLUMNS, CHASES, DUCTS, CONDUITS, AND OTHER ITEMS NOT NORMALLY LEFT
EXPOSED IN A CLASS "A" FINISHED SPACE SHOULD BE ENCLOSED IN AN ENCLOSURE MATCHING THE
FINISH OF ADJACENT WALLS, WHEREVER ENCOUNTERED.
6. EXISTING COMPONENTS THAT ARE TO REMAIN FOR REUSE IN THE NEW CONSTRUCTION, SUCH AS:
THERMOSTATS, SMOKE DETECTORS, FIRE CONTROL EQUIPMENT, DUCTS, LIGHTS, AUTOMATIC
SPRINKLER COMPONENTS, CONDUITS, PIPES, WIRES, CABLES ETC. SHOULD BE RELOCATED OR
REINSTALLED TO ACHIEVE PROPER FUNCTIONING OF THE SPACE, CODE COMPLIANCE, OR AS MAY
BE REQUIRED BY THE PROJECT MANAGER OR GOVERNMENTAL OFFICIALS HAVING JURISDICTION.
7. WHERE AN EXISTING WALL IS TO REMAIN AND INCLUDE A PATCH FROM A FORMER PENETRATION
FOR A DOOR OR OTHER ELEMENT; INSTEAD OF PRODUCING A STANDARD WALL TYPE IN THE PATCH,
CONTRACTOR WILL MATCH THE FIRE RATING, FINISH AND CONSTRUCTION TYPE OF THE ADJOINING
WALL. ALL EXISTING AND NEW, BATT OR RIGID INSULATION, OR OTHER HARMFUL PRODUCTS ARE TO
BE SEALED BEHIND A BARRIER RECOMMENDED BY THE PRODUCT MANUFACTURER FOR
ENCAPSULATING HIS PRODUCT. WHERE AN EXISTING WALL IS TO REMAIN AND HAS BEEN DAMAGED,
WALL SHALL BE PATCHED TO "LIKE NEW" CONDITION AND FINISHED TO MATCH ADJACENT PARTITION
OR AS NOTED ON THE STANDARD FINISH AND EQUIPMENT SCHEDULE.
8. A PARTITION IN THE PLAN SHOWN CONNECTED WITH A WINDOW MULLION SHALL BE CENTERED ON
THAT MULLION AND SHALL BE PROVIDED WITH A CLOSURE DEVICE TO ACCOMPLISH COMPLETE
SEPARATION BETWEEN THE ADJACENT SPACES.
9. WHERE A CORRIDOR, ROOM OR OTHER SPACE IS MODIFIED; THE FINISHES, AND EQUIPMENT
RELATED TO THE NEW BUILD OUT WILL BE EXTENDED OR REDUCED WITH MATERIALS MATCHING
EXACTLY THE FINISHES AND EQUIPMENT OF THE OLD SPACE. FOR EXAMPLE, IN PUBLIC CORRIDOR
EXTENSIONS; LIGHTS, WALL COVERINGS, CEILING FINISHES, BASE, CARPET, PAINTING, AND OTHER
EXISTING ELEMENTS MATCHING THE EXISTING FINISHES SHOULD BE EXTENDED. IF AN EXACT
MATCH IS NOT POSSIBLE, NEW MATERIALS SATISFACTORY TO THE PM SHOULD BE EXTENDED TO A
SATISFACTORY BREAK POINT.
10. UNLESS OTHERWISE NOTED, ALL SURFACES EXPOSED WITHIN A FINISH SPACE WILL BE PAINTED.
THIS INCLUDES ALL ELECTRICAL PANEL COVERS, CONDUIT, GREENFIELD, NON-STAIN &
NON-LAMINATE MILLWORK SURFACES, GYPSUM BOARD, PAINTED TRIM, HOLLOW METAL, CMU,
EXPOSED CONCRETE FLOORS, FACTORY PRIMED METALS, GRAY OR OTHER COLORED FACTORY
FINISHED PANEL & ACCESS DOOR COVERS, AND ALL PREVIOUSLY PAINTED SURFACES. UNLESS
OTHERWISE NOTED, ITEMS NOT TO BE PAINTED WILL INCLUDE, LAMINATE SURFACES, STAINED OR
CLEAR FINISH HARDWOODS, CARPET, RESILIENT FLOORING, VINYL BASE, CERAMIC OR PORCELAIN
TILE, STONE OR QUARRY TILE, ACOUSTICAL TILE CEILINGS & GRIDS, DOOR AND CABINET HARDWARE,
LIGHTS, OUTLET, PHONE, DATA, & SWITCH COVER PLATES (UNLESS PREVIOUSLY PAINTED).
11. IMMEDIATELY UPON AWARDING OF THE CONTRACT, CONTRACTOR WILL VERIFY ALL FIELD
DIMENSIONS, CONFIRM THE OPERATION OF ALL SYSTEMS TO BE REUSED, DETERMINE THE
EXISTENCE OF ANY TOXIC OR HAZARDOUS ELEMENTS IN THE PREVIOUS CONSTRUCTION, EXPOSE
HIDDEN CONDITIONS THAT MAY AFFECT THE PROJECT AND CONFIRM DELIVERY OF ALL REQUIRED
COMPONENTS. CONTRACTOR WILL REVIEW SLAB PENETRATIONS, SLAB PERIMETERS, EXIT ACCESS
CORRIDOR WALLS, SHAFT ENCLOSURES, STAIR AND EXIT ENCLOSURES, FIRE AND SMOKE DAMPERS,
AND OTHER EXISTING RATED ENCLOSURES TO BE CERTAIN THAT THEY ARE CONTINUOUS
ASSEMBLIES, WITH APPROPRIATE SEAL AT ALL PENETRATIONS AND PERIMETERS. WITHIN SEVEN
CALENDAR DAYS OF CONTRACT AWARD, HE WILL NOTIFY PM OF ANY CONFLICTS OR PROBLEMS.
12. CONSTRUCTION SHALL ONLY PROCEED BASED UPON THE APPROVED PERMIT DRAWINGS,
INCLUDING ALL JURISDICTIONAL PERMITS. WORK UNDERTAKEN THAT DOES NOT CONFORM TO
THESE DRAWINGS WILL BE AT THE CONTRACTOR'S RISK.
13. WHERE NEW EQUIPMENT OR MATERIALS ARE TO BE SUSPENDED FROM THE STRUCTURE OR
PLACED ON THE STRUCTURE, THE CONTRACTOR IS RESPONSIBLE FOR ASSURING ADEQUATE
SUPPORT. IF THE STRUCTURE REQUIRES ALTERATION (THE ADDITION OR DELETION OF PORTIONS
OF THE BUILDING STRUCTURE), THE DESIGN MUST BE PREPARED BY A LICENSED STRUCTURAL
ENGINEER AND PERFORMED UNDER THE ENGINEER'S DIRECTION. ALL STRUCTURAL ALTERATION
DESIGNS MUST BE BROUGHT TO THE ATTENTION OF THE PM, IN WRITING, BEFORE THE WORK IS TO
BEGIN.
14. THE CONTRACTOR WILL PROVIDE THE APPROPRIATE, MANUFACTURER RECOMMENDED,
SUBSTRATE AND CONTROL/ EXPANSION JOINTS FOR ALL FINISHES, INCLUDING BUT NOT LIMITED TO
FLOORING, WALLS, CEILING, ETC.
00810 SAFETY
1. THE CONTRACTOR AND SUBCONTRACTORS TAKE FULL RESPONSIBILITY FOR THE SAFETY OF
THEIR OWN WORKMEN, EMPLOYEES OF THE OWNER, THE GENERAL PUBLIC, AND ALL OTHERS THAT
MAY BE AFFECTED BY THE ACCOMPLISHMENT OF THE WORK OF THIS PROJECT.
00840 START / SERVICE INTERRUPTIONS
1. THE CONTRACTOR SHALL PROVIDE FIVE DAYS WRITTEN NOTICE PRIOR TO COMMENCEMENT OF
WORK; SHALL GIVE 48 HOURS WRITTEN NOTICE PRIOR TO THE SHUTDOWN OF ANY OPERATING
SYSTEM; AND SHALL BE RESPONSIBLE FOR COOPERATING WITH THE OWNER TO MAINTAIN FULL
OPERATIONS DURING THE CONSTRUCTION PERIOD.
01000 GENERAL CONDITIONS
1. UNLESS OTHERWISE NOTED HEREIN, THE GENERAL CONDITIONS OF THE CONTRACT FOR
CONSTRUCTION, AIA DOCUMENT A201, CURRENT EDITION, SHALL GOVERN AS THE GENERAL
CONDITIONS OF THIS PROJECT. THE OTHER SECTIONS OF THIS SPECIFICATION SHALL SUPERCEDE
THESE GENERAL CONDITIONS IF THEY ARE IN CONFLICT.
01045 CUTTING, PATCHING, DEMOLITION & PROTECTION
1. THE WORK OF THIS PROJECT INCLUDES THE REMOVAL OF ALL ITEMS AND SYSTEMS NECESSARY
TO PRODUCE A COMPLETE JOB. WHERE AN ITEM TO BE REMOVED IS PART OF AN OPERATING
SYSTEM, THE CONTRACTOR WILL MAKE ALL ADJUSTMENTS NECESSARY TO MAINTAIN THE FULL
OPERATION OF THE REMAINING PORTIONS OF THAT SYSTEM. WHEREVER PENETRATIONS TO AN
EXISTING FIRE RATED ASSEMBLY ARE MADE, THE CONTRACTOR WILL PROVIDE CODE MANDATED
FIRE DAMPER, FIRE STOP, RATED ACCESS PANEL OR DOOR, WALL PATCH, OR OTHER
CONSTRUCTION REQUIRED TO MAINTAIN THE INTEGRITY OF THE EXISTING BARRIER. THE
DEMOLITION AND NEW CONSTRUCTION WORK INCLUDES THE PATCHING OF ALL INTERFACES WITH
FINISHES MATCHING EXACTLY THE ADJACENT/PREVIOUS MATERIAL, UNLESS OTHERWISE NOTED, SO
THAT NO EVIDENCE OF THE PATCH IS VISIBLE.
2. THE DEMOLITION DRAWINGS GENERALLY INDICATE ONLY A SCHEMATIC LAYOUT OF THE WALLS TO
BE REMOVED. IN ADDITION TO REMOVING THESE WALLS, THE DEMOLITION AND PATCHING WORK
WILL INCLUDE REMOVAL AND PATCHING OF ALL ITEMS REQUIRED BY OTHER DISCIPLINES, SUCH AS
MECHANICAL, ELECTRICAL, STRUCTURAL, AND OTHERS. UNLESS OTHER WISE SPECIFIED IN THE
PLAN DOCUMENTS, ALL WALLPAPER IS TO BE REMOVED FROM ALL WALL SURFACES AND THE
SURFACES ARE TO BE PREPARED FOR PAINTING. CONTRACTOR WILL ALSO ASSUME THAT ALL
EXISTING FLOOR FINISHES,BASE, ADHESIVES, PANELING, UNUSED CONDUITS, PIPES, WIRES,
CABLES, AND OTHER EQUIPMENT AND FINISHES ARE TO BE REMOVED. BEFORE BEGINNING
DEMOLITION, OBTAIN SPECIFIC WRITTEN PM CONFIRMATION THAT THE DEMOLITION REQUIRED FOR
THIS PROJECT INCLUDES THIS WORK AND SPECIFIC DIRECTION ON ITEMS THAT ARE TO BE
SALVAGED OR RETAINED.
3. THE CONTRACTOR IS RESPONSIBLE FOR PROTECTING ALL MERCHANDISE, EXISTING FINISHES,
EQUIPMENT, SYSTEMS TO REMAIN, AND ALL OTHER PHYSICAL ELEMENTS THROUGHOUT THE
PROGRESS OF THE WORK. IF THE STAGING OF THE PROJECT REQUIRES, THE CONTRACTOR WILL
ERECT TEMPORARY PROTECTIVE WALLS SUFFICIENT TO ISOLATE ALL OCCUPIED AREAS FROM
CONSTRUCTION AREAS. THESE BARRIERS WILL BE SUFFICIENT IN THEIR CONSTRUCTION TO
PROTECT THE OCCUPANTS SAFETY AND HEALTH AS WELL AS PROVIDING A CLEAN WORK
ENVIRONMENT. WORK ACCOMPLISHED IN PARTIALLY OCCUPIED SPACE MAY BE LIMITED TO
UNOCCUPIED HOURS OR MAY HAVE RESTRICTIONS ON NOISE PRODUCING CONSTRUCTION
OPERATIONS AT THE PROJECT MANAGER'S DISCRETION.
4. WHERE AN EXISTING SYSTEM, FINISH OR ARTICLE OF EQUIPMENT IS IN NEED OF REPLACEMENT
OR MODIFICATION TO BRING THE EXISTING ITEM TO A "LIKE NEW" CONDITION, THE CONTRACTOR
WILL UNDERTAKE THIS WORK AS PART OF THIS CONTRACT.
5. DEMOLITION INCLUDES CONTROLLED DESTRUCTION OF BUILT ELEMENTS, SALVAGE AND
STORAGE IN THE BUILDING OF PM DESIGNATED ITEMS, AND THE REMOVAL AND DISPOSAL OF
DEMOLISHED MATERIALS REQUIRED FOR THE NEW CONSTRUCTION OR SHOWN ON THE DRAWINGS
AND NOTES. DEMOLITION WILL BE UNDERTAKEN IN SECTIONS SMALL ENOUGH TO PREVENT DAMAGE
OF MATERIALS TO REMAIN IN PLACE.
6. WHERE THE WORK INCLUDES REMOVAL OF SOILS, STRUCTURAL ELEMENTS OR OTHER
DANGEROUS DEMOLITION OPERATIONS, ADEQUATE SHORING, BRACING AND PROTECTION TO
PREVENT MOVEMENT, SETTLEMENT, COLLAPSE OR DAMAGE TO EXISTING MATERIALS AND ITEMS TO
REMAIN WILL BE PROVIDED. SUBMIT COMPLETE DETAILS OF SHORING AND BRACING PROCEDURES
SIGNED BY A REGISTERED PROFESSIONAL ENGINEER PRIOR TO BEGINNING WORK.
7. PROMPTLY REPAIR ALL DAMAGES CAUSED BY THE DEMOLITION TO ADJACENT ITEMS, MATERIALS,
ETC. AT NO COST TO THE OWNER.
8. PROMPTLY REMOVE FROM SITE AND PROPERLY DISPOSE OF ALL DEBRIS, RUBBISH AND OTHER
MATERIALS RESULTING FROM THE DEMOLITION.
01300 SUBMITTALS
1. UNLESS OTHERWISE NOTED, ALL REQUIRED SHOP DRAWINGS, CALCULATIONS, LETTERS, AND OTHER
SUBMITTALS WILL BE DELIVERED ELECTRONICALLY IN PDF FORMAT TO THE PM FOR APPROVAL. FOR
SAMPLES OF FINISH MATERIALS, A MINIMUM OF 2 OF EACH TYPE SHALL BE SENT FOR REVIEW IF REQUIRED BY
THE ARIUM PM OR THE CLIENT. WHEN THE SPECIFIED FINISH MATERIAL IS BEING PROVIDED, ELECTRONIC
REVIEW IS PREFERRED.
2. ALL SHOP DRAWINGS OR SUBMITTALS SHALL BE SUBMITTED BY THE GENERAL CONTRACTOR, WITH A
NUMBER AND REVIEW STAMP BY THAT ENTITY. ANY MATERIALS RECEIVED DIRECTLY FROM A
SUB-CONTRACTOR WILL BE REJECTED WITHOUT REVIEW.
3. SINCE APPROVAL OF SUBMITTALS MAY BE REQUIRED FROM MANY ENTITIES, CONTRACTOR SHOULD
ASSUME A MINIMUM OF TWO WEEKS FOR RESPONSE TO SUBMITTALS. NO ORDERS SHOULD BE PLACED, OR
WORK UNDERTAKEN PRIOR TO WRITTEN APPROVAL OF SUBMITTALS.
4. THE CONTRACTOR MUST VERIFY LONG LEAD ITEMS AT THE START OF THE PROJECT TO AVOID DELAYS AND
ALTERNATES.
5. IF ALTERNATE EQUIPMENT OR MATERIAL IS PROPOSED, THE CONTRACTOR MUST PROVIDE DETAILED
DOCUMENTATION TO SHOW THAT THE PROPOSED SUBSTITUTION IS EQUAL TO THE ORIGINALLY SPECIFIED
ITEM. THE CLIENT MAY REQUIRE THAT THE CONTRACTOR PAY FOR ANY ADDITIONAL REVIEW TIME SPENT BY
THE ARCHITECT OR ENGINEER IN THE REVIEW OF THE SUBSTITUTION.
6. WHEN COMPLETING REVIEW OF A SUBMITTAL OR SHOP DRAWING THE ARCHITECT AND/OR ENGINEER WILL
NOT VERIFY THE QUANTITY OF MATERIALS TO BE PROVIDED, THE HANDING OF DOORS, OR THE REQUIRED
THROAT DEPTH FOR JAMBS.
7. THE ARCHITECT AND/OR ENGINEER WILL NOT REVIEW OR TAKE RESPONSIBILITY FOR SHOP DRAWINGS OR
SUBMITTALS FOR ANY PRODUCT OR EQUIPMENT THAT IS NOT INCLUDED AS PART OF THE SCOPE OF WORK
FOR THE PROJECT AS DETAILED WITHIN THE CONSTRUCTION DOCUMENTS.
8. CHECKING IS ONLY FOR GENERAL CONFORMANCE WITH THE DESIGN CONCEPT OF THE PROJECT AND
GENERAL COMPLIANCE WITH THE INFORMATION GIVEN IN THE CONTRACT DOCUMENTS. ANY ACTION SHOWN
IS SUBJECT TO THE REQUIREMENTS OF THE PLANS AND SPECIFICATIONS. CONTRACTOR IS RESPONSIBLE
FOR: DIMENSIONS WHICH SHALL BE CONFIRMED AND CORRELATED AT THE JOB SITE; FABRICATION
PROCESSES AND TECHNIQUES OF CONSTRUCTION; COORDINATION OF HIS WORK WITH THAT OF ALL OTHER
TRADES; AND THE SATISFACTORY PERFORMANCE OF HIS WORK.
01700 SUBSTANTIAL COMPLETION
1. THE PROJECT MANAGER SHALL DETERMINE THE DATE OF SUBSTANTIAL COMPLETION AND FINAL
PAYMENT.
2. PRIOR TO SUBSTANTIAL COMPLETION, THE AREA AFFECTED BY THE CONSTRUCTION WILL BE
CLEANED TO THE PROJECT MANAGER'S SATISFACTION AND ALL SYSTEMS WILL BE DEMONSTRATED
TO BE WORKING IN GOOD ORDER BY THE CONTRACTOR. ALL FINAL CONSTRUCTION PERMIT SIGN
OFFS AND USE & OCCUPANCY PERMITS WILL BE OBTAINED, MAINTENANCE INSTRUCTIONS, PRODUCT
WARRANTIES, A FULL SET OF AS BUILT DRAWINGS AND ANY REQUESTED RELEASE OF LIENS OR
OTHER DOCUMENTS, WILL ALSO BE DELIVERED TO THE PROJECT MANAGER.
01740 WARRANTIES AND BONDS
1. THE CONTRACTOR AND SUBCONTRACTORS WARRANT THAT ALL WORK PERFORMED UNDER THIS
CONTRACT WILL PERFORM IN PERFECT CONDITION UNDER NORMAL USE FOR ONE FULL YEAR
BEYOND THE DATE OF SUBSTANTIAL COMPLETION.
03100 CONCRETE
1. ALL CONCRETE WORK INCLUDING FORMING, MIXING, PLACING AND CURING SHALL BE IN
ACCORDANCE WITH A.C.I.310. CONCRETE REINFORCING WILL COMPLY WITH A.S.T.M. A-615 GRADE 60.
SUBMIT COMPLETE SHOP AND ERECTION DRAWINGS FOR REVIEW PRIOR TO FABRICATION OR
ERECTION. WELDED WIRE MESH TO BE A.S.T.M. A-185. UNLESS THE AFOREMENTIONED STANDARDS
OR SPECIFIC DRAWING NOTES INDICATE OTHERWISE, CONCRETE SHALL HAVE A 28 DAY
COMPRESSIVE STRENGTH OF: 3,000 P.S.I. REINFORCING FOR CONCRETE EXPOSED TO GROUND OR
WEATHER SHALL HAVE 2" CONCRETE COVER AFTER REMOVAL OF FORMS. USE A WATER REDUCING
ADMIXTURE IN ALL CONCRETE. SLUMP - AS REQUIRED BY ACI EXCEPT THAT SLABS ON GRADE SHALL
HAVE A MAXIMUM SLUMP OF 2 1/2". AIR ENTRAIN ALL EXPOSED CONCRETE 5% +/- 1%. NO CALCIUM
CHLORIDE IN ANY FORM WILL BE PERMITTED IN CONCRETE.
2. CONCRETE WALKING SURFACES WILL HAVE A SLIP RESISTANT FINISH. THEY WILL PROVIDE A
SMOOTH, TRIP FREE, TRANSITION BETWEEN PANELS AND TRANSITIONS TO OTHER WALKING
SURFACES. THRESHOLDS AND TACTILE WARNINGS SHOULD BE COORDINATED TO COMPLY WITH
ADA STANDARDS. EXTERIOR WALKING SURFACES SHOULD BE SLOPED TO PROVIDE POSITIVE
DRAINAGE. WALKING SURFACES WITH STEPS OR SLOPES FROM 1 IN 12 TO 1 IN 20 WILL INCLUDE
HANDRAILS AND GUARDS AND BE KEPT FREE OF SNOW AND ICE BY A COVERING OR OWNER
AGREED MAINTENANCE AGREEMENT. NO WALKING SURFACE WILL HAVE A SLOPE GREATER THAN 1
IN 12.
3. WHERE CONCRETE SLABS ABUT ANOTHER WALKING SURFACE, EVERY PRECAUTION SHOULD BE
TAKEN TO PREVENT HEAVING OR SETTLEMENT OF THE NEW CONCRETE. APPLICABLE CONTROL
MEASURES SHOULD INCLUDE: TURN DOWN EDGES TO BELOW THE FROST LINE, DOWELING TO
ADJOINING SURFACES, AND PLACEMENT ON COMPACTED FILL.
4. UNLESS OTHERWISE NOTED, ON EXTERIOR CONCRETE WORK, GRADING WILL BE ADJUSTED TO
PROVIDE A MAXIMUM SLOPE OF 1 IN 3 ON AREAS ADJUSTED FOR CONCRETE PLACEMENT.
LANDSCAPING AND PLANTING IN REGRADED AREAS WILL BE REPLACED WITH MATERIALS MATCHING
THE PREVIOUS LANDSCAPING
07560 ROOFING REPAIRS
1. ALL NEW ROOF PENETRATIONS SHALL BE SEALED AND FLASHED IN ORDER TO MAINTAIN THE
INTEGRITY OF THE ROOF.
2. IF A "ROOF WARRANTY" IS IN EFFECT, THEN ALL REPAIRS MUST BE PERFORMED BY THE
APPROPRIATE PARTIES AND WITH APPROPRIATE MATERIALS TO MAINTAIN THE WARRANTY.
3. IF NO "ROOF WARRANTY" IS IN EFFECT, THEN ALL FLASHINGS, SEALANTS AND OTHER
MATERIALS ARE TO BE COMPATIBLE WITH THE EXISTING ROOFING SYSTEM. ALL MATERIALS AND
METHODS MUST BE IN CONFORMANCE WITH "THE NATIONAL ROOFING CONTRACTORS ASSOCIATION
ROOFING AND WATERPROOFING MANUAL." WORK MUST BE PERFORMED BY ROOFING INSTALLERS
WHO ARE SKILLED AND EXPERIENCED WITH THE EXISTING ROOFING SYSTEM.
08110 STEEL DOORS AND FRAMES
1. ALL STEEL DOORS AND FRAMES WILL BE CONSTRUCTED IN ACCORDANCE WITH THE
CURRENT STANDARDS OF THE STEEL DOOR INSTITUTE (SDI 100-83).
2. IN PARTITIONS WITH A NOTED RATING FOR A DOOR, THE ACCOMPANYING STEEL FRAME WILL
CARRY A RATING THAT WILL PROVIDE THE TOTAL ASSEMBLY WITH THE RATING OF THE SPECIFIED
DOOR.
3. INTERIOR STEEL DOORS TO BE SDI-100, GRADE II, HEAVY DUTY, MODEL 1, 18-GAUGE FACES,
CARBON STEEL, SHOP PRIMED WITH A RUST INHIBITIVE PRIMER SUITABLE AS A BASE FOR THE
SPECIFIED FINAL FINISH.
4. EXTERIOR STEEL DOORS TO BE SDI-100, GRADE III, EXTRA HEAVY DUTY, MODEL 2, 16-GAUGE
FACES, SHOP PRIMED WITH A RUST INHIBITIVE PRIMER SUITABLE AS A BASE FOR THE SPECIFIED
FINAL FINISH.
5. STEEL FRAMES WILL MATCH THE GAUGE, GALVANIZED AND PRIMER REQUIREMENTS AND SDI
STANDARDS FOR THE LISTED DOOR. ALL FRAMES WILL HAVE CONCEALED FASTENERS, DOOR
SILENCERS, MITERED CORNERS (WELDED AT EXTERIOR LOCATIONS) AND MORTISED HINGE AND
STRIKE LOCATIONS SET TO RECEIVE THE SPECIFIED HARDWARE.
08200 WOOD DOORS AND WOOD FRAMES
1. ALL WOOD DOORS AND WOOD FRAMES WILL BE CONSTRUCTED AND INSTALLED IN
ACCORDANCE WITH THE CRITERIA AND STANDARDS OF THE ARCHITECTURAL WOODWORK
INSTITUTE FOR THE PROPOSED USE. HOLLOW CORE OPAQUE FINISH DOORS WILL FOLLOW IHC
STANDARDS UNLESS PM APPROVES A SHC MANUFACTURER. DOORS AND FRAMES TO RECEIVE
OPAQUE FINISHES CAN BE CONSTRUCTED TO CUSTOM GRADE. TRANSPARENT AND OTHER FINISH
DOORS AND FRAMES WILL BE CONSTRUCTED TO PREMIUM GRADE STANDARDS. EXCEPT FOR DOOR
EDGES, THERE WILL BE NO VISIBLE FINGER JOINTS.
2. IN PARTITIONS WITH A NOTED RATING FOR A DOOR, THE ACCOMPANYING FRAME WILL CARRY
A RATING THAT WILL PROVIDE THE TOTAL ASSEMBLY WITH THE RATING OF THE SPECIFIED DOOR.
3. ALL FRAMES WILL HAVE CONCEALED FASTENERS, DOOR SILENCERS, MITERED CORNERS,
AND MORTISED HINGE AND STRIKE LOCATIONS SET TO RECEIVE THE SPECIFIED HARDWARE.
08305 ACCESS DOORS
1. CONTRACTOR WILL COORDINATE THE WORK WITH ALL TRADES REQUIRING ACCESS TO
CONCEALED ITEMS. WHERE SUCH ACCESS IS REQUIRED, CONTRACTOR WILL PROVIDE AN
APPROPRIATELY SIZED AND UL LABELED, IF REQUIRED, ACCESS DOOR. DOORS AND FRAMES WILL
INCLUDE ONE CYLINDER LOCK KEYED THE SAME FOR EACH ACCESS PANEL AND A MINIMUM OF TWO
KEYS PER PANEL.
UTILITIES SHALL BE COORDINATED TO BE GROUPED IN ORDER TO REDUCE THE SIZE AND/OR
QUANTITY OF ACCESS PANELS REQUIRED, WHEREVER FEASIBLE. ACCESS PANELS IN WALL TILE
AREAS SHALL BE STAINLESS STEEL FINISH AND CENTERED ABOVE PLUMBING FIXTURES. ACCESS
PANELS IN GYP. BOARD WALLS AND CEILINGS SHALL BE 'STEALTH' MODEL BY WIND-LOCK (OR
EQUAL).
2. CONTRACTOR SHALL NOTIFY ARCHITECT OF QUANTITIES AND LOCATIONS PRIOR TO FRAMING
& INSTALLATION OF ACCESS PANELS.
08710 FINISH HARDWARE
1. MOUNTING HEIGHTS WILL CONFORM TO THE ADA. WHERE THE ADA DOES NOT ADDRESS
MOUNTING HEIGHT THE DOOR AND HARDWARE INSTITUTE STANDARDS WILL PREVAIL. NOTE:
LATCHSETS ARE TO BE MOUNTED AT THE SAME HEIGHT AS BUILDING STANDARD PROVIDING THE
BUILDING STANDARD MEETS THE ADA: THE ADA WILL TAKE PRECEDENTS.
2. UNLESS OTHERWISE NOTED EACH DOOR SHALL RECEIVE THE STANDARD PASSAGE LATCH,
SILENCERS, FULL MINIMUM 3 MORTISE HINGES (NUMBER AND SIZED TO ACCOMMODATE WEIGHT AND
DIMENSION OF SPECIFIED DOOR) AND STRIKE. PROVIDE A WALL MOUNTED DOOR STOP. WHERE A
WALL STOP IS NOT POSSIBLE, PROVIDE A FLOOR MOUNTED STOP LOCATED OUT OF THE FLOW OF
NORMAL TRAFFIC. AT DOUBLE DOORS PROVIDE TOP AND BOTTOM SURFACE MOUNTED BOLTS AND
STRIKES ON THE INACTIVE LEAF. AT FIRE RATED DOUBLE DOORS PROVIDE ASTRAGAL CLOSURES
MATCHING THE DOOR FINISH AS MAY BE REQUIRED TO MAINTAIN THE RATED ASSEMBLY. IN
ADDITION, AT ALL EXTERIOR DOORS PROVIDE CLOSERS, COMPLETE WEATHERSTRIPPING,
THRESHOLD WEATHER SEAL AND MATCHING ASTRAGALS FOR DOUBLE DOORS.
3. DOORS SO NOTED, DOORS TO TENANT SUITES, REST ROOMS ENTRY DOORS, VESTIBULE
DOORS, SMOKE BARRIER DOORS, ALL DOORS IN RATED WALLS, AND DOORS IN RATED ASSEMBLIES
WILL INCLUDE AUTOMATIC CLOSERS. DOORS OPENING ON PUBLIC CORRIDORS, AND REQUIRING
CLOSERS, SHALL HAVE THEIR CLOSERS LOCATED ON THE TENANT SIDE OF DOOR; A REVERSE
ACTING CLOSER SHALL BE USED WHEN A DOOR OPENS INTO A TENANT SPACE. WHERE REQUIRED
BY CODE FOR DOUBLE DOORS, PROVIDE SEQUENCING TYPE CLOSER. COORDINATE THE CLOSER
TYPE WITH THE HOLD OPEN HARDWARE.
4. UNLESS OTHERWISE NOTED ALL EXPOSED HARDWARE WILL BE OF A CONSISTENT FINISH AS
LISTED ON THE STANDARD FINISH & EQUIPMENT SCHEDULE FOR "HARDWARE" OR THE DOOR TYPE
SCHEDULE FOR "HARDWARE FINISH".
5. DOORS LEADING TO THE EXTERIOR, LOBBIES, CORRIDORS AND OTHER NON TENANT SPACES
WILL INCLUDE BUILDING MASTER KEYED LOCKSETS, HINGES, AND ALL OTHER HARDWARE
CONFORMING TO THE BUILDING STANDARD OR IF NO STANDARD EXISTS, MATCHING ADJACENT
HARDWARE IN THE PUBLIC SPACE. KEYING FOR LOCKSETS WILL CONFORM TO THE PROJECT
MANAGER'S WISHES.
09250 GYPSUM BOARD
1. ALL GYPSUM BOARD CONSTRUCTION WILL BE IN ACCORDANCE WITH THE CRITERIA OF THE
CURRENT EDITION OF THE "GYPSUM CONSTRUCTION HANDBOOK" PUBLISHED BY U.S. GYPSUM.
2. ALL ASSEMBLIES NOTED TO HAVE A SPECIFIED FIRE RESISTANCE RATING WILL BE
CONSTRUCTED IN STRICT ACCORDANCE WITH THE CRITERIA FOR CONSTRUCTION OF THE TESTED
ASSEMBLY.
3. TYPE X OR TYPE C GYPSUM BOARD WILL BE USED IN ALL FIRE RATED ASSEMBLIES. WATER
RESISTANT GYPSUM BOARD WILL BE USED IN ALL AREAS SUBJECT TO INTERMITTENT WETTING SUCH
AS SHOWER OR PLUMBING WALLS AND BEHIND ALL CERAMIC TILE. EXTERIOR GYPSUM SHEATHING
WILL BE USED IN ALL OUTSIDE APPLICATIONS.
4. STUD WIDTH, GAUGE, AND ON CENTER SPACING WILL BE IN ACCORDANCE WITH THOSE
LISTED IN THE PARTITION NOTES. IF THE CONTRACTOR'S REVIEW OF FIELD CONDITIONS UNCOVERS
A SPAN FOR THE STUDS THAT EXCEEDS THE LISTED MAXIMUM, NOTIFY PROJECT MANAGER. IF
LOADS ARE TO BE PLACED ON PARTITION OTHER THAN AS SHOWN ON THE ARCHITECTURAL
DRAWING, NOTIFY THE PROJECT MANAGER BEFORE PROCEEDING.
5. CONTRACTOR MAY USE THE DRAWING INFORMATION AS A GUIDE IN SIZING LIGHT GAUGE
METAL STUDS. AS A DESIGN BUILD ELEMENT, CONTRACTOR IS ULTIMATELY RESPONSIBLE FOR ALL
ENGINEERING DESIGN FOR ALL LIGHT GAUGE METAL FRAMING. CONTRACTOR WILL MAKE
PROVISIONS FOR ADEQUATE BRACING TO THE EXISTING STRUCTURE TO PROVIDE A SECURE AND
STABLE CONSTRUCTION CAPABLE OF HANDLING ALL NORMAL LOADS. IN AREAS WHERE THERE IS
ANY DOUBT ON THE ADEQUACY OF THE DESIGN, CONTRACTOR WILL EMPLOY A LOCALLY
REGISTERED PROFESSIONAL ENGINEER TO INSURE THAT AN ADEQUATE DESIGN IS PUT IN PLACE.
6. METAL CORNER AND END BEADS ON GYPSUM BOARD, CONFORMING TO USG STANDARDS
AND TYPES, WILL BE PROVIDED AT ALL POSSIBLE LOCATIONS. WALLS STOPPING AT ACOUSTICAL
TILE OR OTHER NON GYPSUM BOARD CEILINGS WILL RECEIVE END BEADS AS SPECIFIED IN THE
STANDARD FINISHES AND EQUIPMENT SCHEDULE.
7. ALL GYPSUM BOARD IS TO BE TAPED AND SPACKLED IN ACCORDANCE WITH ESTABLISHED
PROCEDURES FOR THE FULL HEIGHT OF THE PARTITION. FOR NON RATED DECK TO DECK
ASSEMBLIES, GYPSUM SHALL BE SANDED AND FINISHED IN ACCORDANCE WITH ESTABLISHED
PROCEDURES TO A HEIGHT OF 4" ABOVE THE FINISHED CEILING. FOR RATED ASSEMBLIES, THE
GYPSUM BOARD FINISH WILL BE EXTENDED TO CONFORM TO THE RATING REQUIREMENTS. NO RIGID,
BATT OR OTHER INSULATION SHALL BE LEFT EXPOSED IN A PLENUM, ROOM, OR OTHER AREA IN
CONTACT WITH THE AIR USED WITHIN A SPACE.
8. STANDARD LEVEL OF GYPSUM BOARD FINISH SHALL BE LEVEL #4, EXCEPT AS RECOMMENDED
BY GYPSUM ASSOCIATION GA-214-M-97.
09510 ACOUSTICAL CEILINGS
1. ACOUSTICAL CEILINGS WILL USE THE SCHEDULED MANUFACTURER IN NEW INSTALLATIONS.
2. IN AREAS WHERE THE ACOUSTICAL CEILING IS AN EXTENSION OF AN EXISTING ACOUSTICAL
CEILING, THE COMPONENTS OF THE EXTENDED CEILING WILL MATCH THE EXISTING ADJACENT
CEILING COMPONENTS AND BE INSTALLED EXTENDING THE GRID AND TILE PATTERN OF THE
EXISTING CEILING.
3. ACOUSTICAL CEILINGS NOTED TO BE PORTIONS OF RATED ASSEMBLIES WILL BE INSTALLED
IN STRICT ACCORDANCE WITH THE REQUIREMENTS OF THE TESTED ASSEMBLY.
4. WHERE A TEGULAR SCORED OR OTHER MULTI-DIMENSIONAL CEILING TILE IS SPECIFIED, THE
CEILING GRID SHALL BE ADJUSTED IF NECESSARY TO MINIMIZE AN UNEVEN TEGULAR EDGE LINE
WHERE THE TILE MEETS THE WALL.
5. TEGULAR TILES IN A CONTINUOUS CEILING GRID SHALL BE ROUTED TO SIT FLAT ABOVE
FLOOR TO CEILING PARTITIONS. WHERE A TEGULAR TILE MEETS A DECK TO DECK PARTITION, A
WALL ANGLE SHALL BE PLACED AT THE WALL AND THE TILE EDGE, IF NEEDED, WILL BE CUT TO FORM
AN EDGE MATCHING THE TEGULAR EDGE. RAW CUT EDGES OF TILES ADJACENT TO WALLS SHALL
FACE THE WALL. IF RAW EDGE CAN NOT BE CONCEALED, THEN IT SHALL BE COLORED TO MATCH
THE TILE COLOR.
09680 CARPETING
1. CARPETING WILL BE INSTALLED BY THE DIRECT GLUE DOWN PROCESS UNLESS OTHERWISE
NOTED. BEFORE INSTALLATION, CARPET INSTALLER WILL NOTIFY THE PM OF ANY FLOOR AREAS
THAT ARE NOT ACCEPTABLE FOR A SMOOTH, LEVEL, PROPERLY ADHERED INSTALLATION.
2. CARPETING WILL BE OF THE TYPE SPECIFIED IN THE ROOM FINISH SCHEDULE OR STANDARD
FINISH AND EQUIPMENT SCHEDULE.
3. EXCEPT IN CASES WHERE A CMU OR BRICK WALL OCCURS, THE STANDARD BASE SHOWN ON
THE ROOM FINISH SCHEDULE OR THE STANDARD FINISH AND EQUIPMENT SCHEDULE WILL BE
PROVIDED AT ALL LOCATIONS WHERE A VERTICAL SURFACE ABUTS A FLOOR. THIS INCLUDES
GYPSUM BOARD WALLS ABUTTING CONCRETE FLOORS, BASE CABINETS, AND BUILT-IN MILLWORK.
4. EXTENSIONS OF CORRIDORS, AND OTHER NEW CONSTRUCTION THAT IS AN EXTENSION OF A
PREVIOUSLY CARPETED AREA, WILL HAVE CARPET INSTALLED THAT EXTENDS THE CARPET OF THE
PREVIOUSLY BUILT SPACE TO A NATURAL BREAK POINT, SUCH AS A DOORWAY. WHERE CARPET IS
EXTENDED IN THIS MANNER, THE BASE CONSTRUCTION WILL MATCH THE BASE IN THE EXISTING
AREA.
09900 INTERIOR PAINT SCHEDULE
1. ALL WALLS WILL BE PAINTED THE WALL PAINT COLOR LISTED ON THE ROOM FINISH
SCHEDULE OR THE STANDARD FINISH AND EQUIPMENT SCHEDULE.
2. STEEL DOOR FRAMES, SHELVES AND OTHER ITEMS SPECIFIED TO RECEIVE AN OPAQUE
FINISH, WILL BE PAINTED TO MATCH THE PREDOMINANT COLOR OF THE ADJACENT WALL UNLESS
NOTED OTHERWISE IN THE DRAWINGS OR FINISH AND EQUIPMENT SCHEDULES.
3. THE NUMBER OF COATS LISTED BELOW ARE NORMALLY SUFFICIENT TO ACHIEVE COMPLETE
UNIFORM COVERAGE OF THE SUBSTRATES LISTED. WHERE THIS COVERAGE DOES NOT ACHIEVE A
COVERAGE ACCEPTABLE TO THE PM, CONTRACTOR WILL ADD ADDITIONAL COATS AT NO CHARGE.
4. PROVIDE THE FOLLOWING PAINT SYSTEMS FOR THE VARIOUS SUBSTRATES, UNLESS
OTHERWISE NOTED, AND ARE BASED ON THE PRODUCTS OF SHERWIN WILLIAMS. PAINT SYSTEMS
BASED ON PRODUCTS OF DURON OR GLIDDEN ARE ACCEPTABLE, AND MUST BE SUBMITTED FOR
APPROVAL.
CONCRETE MASONRY UNITS:
SEMI-GLOSS FINISH
FILLER:
S-W PREPRITE BLOCK FILLER, B25W25 (16 MILS WET, 8 MILS DRY)
1ST COAT: S-W PROMAR 200 ZERO VOC SEMI-GLOSS, B31-2600 SERIES
2ND COAT: S-W PROMAR 200 ZERO VOC SEMI-GLOSS, B31-2600 SERIES
(4 MILS WET, 1.6 MILS DRY PER COAT.)
GYPSUM DRYWALL SYSTEMS:
SEMI-GLOSS FINISH (TOILET ROOMS, KITCHENS, AND AS NOTED):
PRIMER: S-W PROGREEN 200 PRIMER, B28W600 (4 MILS WET, 1.5 MILS DRY)
1ST COAT: S-W PROMAR 200 ZERO VOC SEMI-GLOSS, B31-2600 SERIES
2ND COAT: S-W PROMAR 200 ZERO VOC SEMI-GLOSS, B31-2600 SERIES
(4 MILS WET, 1.6 MILS DRY PER COAT.)
EG-SHEL FINISH:
PRIMER:
S-W PROGREEN 200 PRIMER, B28W600 (4 MILS WET, 1.5 MILS DRY)
1ST COAT: S-W PROMAR 200 ZERO VOC EGGSHELL, B20-2600 SERIES
2ND COAT: S-W PROMAR 200 ZERO VOC EGGSHELL, B20-2600 SERIES
(4 MILS WET, 1.7 MILS DRY PER COAT.)
FLAT FINISH:
PRIMER:
S-W PROGREEN 200 PRIMER, B28W600 (4 MILS WET, 1.5 MILS DRY)
1ST COAT: PROMAR 200 ZERO VOC FLAT, B30-2600 SERIES
2ND COAT: PROMAR 200 ZERO VOC FLAT, B30-2600 SERIES
(4 MILS WET, 1.6 MILS DRY PER COAT.)
EPOXY SYSTEM (SOLVENT BASE) GLOSS FINISH
1ST COAT: S-W TILE-CLAD HS EPOXY, B62WZ100 SERIES
2ND COAT: S-W TILE-CLAD HS EPOXY, B62WZ100 SERIES (2.5-4 MILS DRY PER COAT)
DRYFALL WATERBOURNE SYSTEMS:
EG-SHEL FINISH:
1ST COAT: LOW VOC WATERBORNE ACRYLIC DRYFALL, EGGSHELL B42-W00082
2ND COAT: LOW VOC WATERBORNE ACRYLIC DRYFALL, EGGSHELL B42-W00082
FLAT FINISH:
1ST COAT: LOW VOC WATERBORNE ACRYLIC DRYFALL, FLAT B42-W00081
2ND COAT: LOW VOC WATERBORNE ACRYLIC DRYFALL, FLAT B42-W00081
WOODWORK AND HARDBOARD:
SEMI-GLOSS FINISH:
PRIMER:
S-W PROGREEN 200 PRIMER, B28W600 (4 MILS WET, 1.5 MILS DRY)
1ST COAT: S-W PROMAR 200 ZERO VOC SEMI-GLOSS, B31-2600 SERIES
2ND COAT: S-W PROMAR 200 ZERO VOC SEMI-GLOSS, B31-2600 SERIES
(4 MILS WET, 1.6 MILS DRY PER COAT.)
STAINED WOODWORK (HARDWOOD):
STAIN: MINWAX 250
2ND COAT: S-W WOOD CLASSICS WB POLYURETHANE GLOSS OR STAIN A68
3RD COAT: S-W WOOD CLASSICS WB POLYURETHANE GLOSS OR STAIN A68
FERROUS METAL:
SEMI-GLOSS FINISH
PRIMER:
S-W PRO-INDUSTRIAL PRO-CRYL UNIVERSAL PRIMER, B66-310 SERIES
1ST COAT: S-W PRO-INDUSTRIAL 0 VOC ACRYLIC SEMI-GLOSS, B66-650 SERIES
2ND COAT: S-W PRO-INDUSTRIAL 0 VOC ACRYLIC SEMI-GLOSS, B66-650 SERIES
ZINC-COATED METAL:
SEMI-GLOSS FINISH
PRIMER:
S-W PRO-INDUSTRIAL PRO-CRYL UNIVERSAL PRIMER, B66-310 SERIES
1ST COAT: S-W PRO-INDUSTRIAL 0 VOC ACRYLIC SEMI-GLOSS, B66-650 SERIES
2ND COAT: S-W PRO-INDUSTRIAL 0 VOC ACRYLIC SEMI-GLOSS, B66-650 SERIES
10522 FIRE EXTINGUISHERS, CABINETS, AND ACCESSORIES
1. FIRE EXTINGUISHERS OF THE SPECIFIED SIZE AND TYPE, LISTED ON THE STANDARD FINISH
AND EQUIPMENT SCHEDULE, WILL BE PROVIDED IN ALL LOCATIONS NOTED ON THE PLANS OR
SPECIFIED BY THE LOCAL GOVERNMENT OFFICIAL HAVING PROJECT JURISDICTION.
2. FIRE EXTINGUISHERS MUST BE MOUNTED IN CABINETS OR RECESSES AS NOTED, SO THAT
NEITHER THE EXTINGUISHER NOR THE CABINET EXTENDS MORE THAN 4" FROM THE FACE OF THE
WALL.
3. ALL EXTINGUISHERS SHOULD CARRY A UL RATING.
4. TOP OF CABINET OR EXTINGUISHER SHALL NOT EXCEED MORE THAN 54" ABOVE FINISH
FLOOR.
5. CONTRACTOR IS TO INCLUDE SPECIFIED NUMBER AND TYPE OF FIRE EXTINGUISHERS AND
CABINETS IN PROJECT SCOPE AND CONTRACT COST. ACTUAL NUMBER OF FIRE EXTINGUISHERS IS
TO BE DETERMINED BY LOCAL OFFICIAL. FINAL COST TO OWNER SHALL BE ADJUSTED
ACCORDINGLY.
6. REUSE OF EXISTING FIRE EXTINGUISHERS OR CABINETS IS AT PM'S OPTION. CONTRACTOR IS
TO NOTIFY PM OF NUMBER OF REUSABLE FIRE EXTINGUISHERS OR CABINETS PRIOR TO PURCHASE
OF ANY NEW FIRE EXTINGUISHERS OR CABINETS.
15000/16000 MECHANICAL & ELECTRICAL
SEE MECHANICAL AND ELECTRICAL DRAWINGS AND SPECIFICATIONS FOR PROJECT CRITERIA
PERTINENT TO THESE SECTIONS.
15300 FIRE PROTECTION
1. IN TILED CEILINGS, SPRINKLER HEADS SHALL BE LOCATED IN THE CENTER OF THE CEILING
TILE. IF CEILING TILE IS 2X4 SCORED TO LOOK LIKE 2X2, SPRINKLER HEADS SHALL BE LOCATED IN
CENTER OF 2X2 PORTION OF CEILING TILE. SPRINKLER HEADS IN CORRIDOR AND LARGE OPEN
AREAS SHALL ALIGN.
MAR 2023
SPECIFICATIONS
T2 -ZT2
SBN KLO
ISSUED FOR 100% REVIEW - DATE: 04-05-2024 - NOT FOR CONSTRUCTION
MAR 2023
ARCHITECT / MEP ENGINEER: DESCRIPTION
DATE
REV. NO.
c
TITLE
PROJECT FILE NAME: LATEST REVISION: ISSUE DATE:
DWG NO.
BY:
COPYRIGHT Arium AE, LLC
SM: PM:
SP95-3CCR
2024
CONTRACTOR:
PROJECT MANAGER:
JBG SMITH
6596 SPRINGFIELD CENTER DRIVE
SPRINGFIELD .VA 22150
571-444-0323
PROJECT:
33215 ROOM CONVERSION
3RD FLOOR
6595 SPRINGFIELD CENTER DRIVE
SPRINGFIELD, VA 22150
SR
MORGAN STATE UNIVERSITY SA+P | 37
36 |
c
MAR 2023
38 |
STUD WIDTH
20 GAUGE STUD (.0312 MIN.)
16"
L/120
17'-4" f
17'-11" f
L/240
13'-10" d
16'-1" d
L/360
12'-0" d
14'-0" d
2-1/2"
24"
L/120
14'-7" f
14'-7" f
L/240
12'-0" d
13'-5" f
L/360
10'-6" d
12'-4" d
16" L/120
22'-7" d
23'-8" f
L/240
17'-11" d
20'-2" d
L/360
15'-7" d
17'-8" d
3-5/8"
24"
L/120
19'-4" f
19'-4" f
L/240
15'-7" d
17'-8" f
L/360
13'-8" d
15'-6" d
16"
L/120
24'-3" d
25'-6" d
L/240
19'-2" d
21'-7" d
L/360
16'-10" d
18'-11" d
4"
24"
L/120
20'-9" f
20'-9" f
L/240
16'-10" d
16'-11" d
L/360
14'-8" d
16'-6" d
16" L/120 32'-11" d
33'-11" f
L/240
26'-1" d
28'-6" d
L/360
22'-10" d
24'-11" d
6"
24"
L/120
25'-3" f
25'-3" f
L/240
22'-10" d
24'-11" d
L/360
19'-11" d
21'-10" d
NOTICE THE TYPICAL LIMITING HEIGHTS TABLES ARE BASED PRIMARILY ON THE
SUGGESTED MINIMUM PHYSICAL AND STRUCTURAL PROPERTIES (Ix AND Sx).
PHYSICAL AND STRUCTURAL PROPERTIES MAY VARY BY REGION AND
MANUFACTURER REQUEST ACTUAL PHYSICAL AND STRUCTURAL PROPERTY DATA
FROM THE STEEL FRAMING MANUFACTURER.
LIMITING CRITERIA: d=DEFLECTION, f=BENDING STRESS, v=SHEAR
THESE CHARTS ARE EXCERPTS FROM UNITED STATES GYPSUM COMPANY
SA923. FOR HIGHER PARTITIONS AND HEAVIER GAUGE STUDS, REFER TO THE
STEEL STUD MANUFACTURER'S ASSOCIATION LIMITING WALL HEIGHT TABLES.
ABBREVIATIONS
AB
ABS
A/C
ACOUS
ADJT
AFF
ALUM
AP
APPD
APX
ARCH
BD
BDRM
BET
BLDG
BLK
BLKG
B.O.
BRG
BRK
BSMT
BT
CAB
CER
CJ
CL
CLG
CLR
CMU
CO
COL
CONC
CONT
CORR
CTR
DBL
DEG
DIA
DIM
DISP
DN
DR
DS
DWG
E
EIFS
EJ
ELEC
ELEV
ENGR
EPS
EQ
EQP
ETC
EWC
EXH
EXP
EX
EXT
FD
FFE
FIN
FIX
FL
STUD
SPACING
ALLOW
DEFLECT
PARTITION ONE
LAYER
- ANCHOR BOLT
- ABOVE BUILDING STANDARD
- AIR CONDITIONING
- ACOUSTIC
- ADJUSTABLE
- ABOVE FINISH FLOOR
- ALUMINUM
- ACCESS PANEL
- APPROVED
- APPROXIMATE
- ARCHITECT
- BOARD
- BEDROOM
- BETWEEN
- BUILDING
- BLOCK
- BLOCKING
- BOTTOM OF
- BEARING
- BRICK
- BASEMENT
- BOTTOM
- CABINET
- CERAMIC
- CONTROL JOINT
- CENTERLINE
- CEILING
- CLEAR
- CONCRETE MASONRY UNIT
- CLEAN OUT
- COLUMN
- CONCRETE
- CONTINUOUS
- CORRIDOR
- CENTER
- DOUBLE
- DEGREE
- DIAMETER
- DIMENSION
- DISPENSER
- DOWN
- DOOR
- DOWN SPOUT
- DRAWING
- EAST
- EXTERIOR INSULATION
AND FINISH SYSTEM
- EXPANSION JOINT
- ELECTRIC
- ELEVATOR/ELEVATION
- ENGINEER
- EXPANDED POLYSTYRENE
- EQUAL
- EQUIPMENT
- ETCETERA
- ELECTRIC WATER COOLER
- EXHAUST
- EXPANSION
- EXISTING
- EXTERIOR
- FLOOR DRAIN
- FINISH FLOOR ELEVATION
- FINISH
- FIXTURE
- FLOOR
PARTITION TWO
LAYERS
FOR PAINTED GYPSUM BOARD USE L/120.
FOR VENEER PLASTER USE L/240.
FOR PLASTER LATHE USE L/360.
FOR TILE ON BACKER BOARD USE L/360.
FOR OTHER MATERIALS CONSULT WITH THE MANUFACTURER.
FLUR
FRT
FT
FTG
FUT
GA
GALV
GC
GL
GYP
HB
HC
HDCP
HDWR
HM
HORIZ
H
ID
IE
IN
INCL
INSUL
INT
JT
K
KIT
KO
L
LAM
LAV
LB
LH
LIN
LT
M
M.O.
MAS
MAX
MECH
MED
MEZZ
MFR
MIN
MLD
MOD
MTL
MAT
MUL
N/A
N
NIC
NO
NOM
NTS
OC
OD
OFF
OH
OFCI
OPG
OPH
OZ
FURRING
ONE LAYER
25 GAUGE STUD (.0179 MIN.)
16'-6" d
16"
L/120
13'-0" d
L/240
11'-6" d
L/360
1-5/8"
14'-6" d
24"
L/120
11'-6" d
L/240
10'-0" d
L/360
21'-9" d
16"
L/120
17'-3" d
L/240
15'-0" d
L/360
2-1/2"
19'-0" d
24"
L/120
15'-0" d
L/240
13'-3" d
L/360
23'-6" d
16"
L/120
18'-9" d
L/240
16'-3" d
L/360
3-5/8"
20'-6" d
24"
L/120
16'-3" d
L/240
14'-3" d
L/360
32'-3" d 16"
L/120
25'-6" d
L/240
23'-3" d
L/360
4"
28'-0" d
24"
L/120
22'-3" d
L/240
19'-6" d
L/360
16"
L/120
6"
STUD WIDTH
- FLUORESCENT
- FIRE RETARDANT TREATED
- FEET
- FOOTING
- FUTURE
- GAUGE
- GALVANIZED
- GENERAL CONTRACTOR
- GLASS
- GYPSUM
- HOSE BIB
- HOLLOW CORE
- HANDICAP
- HARDWARE
- HOLLOW METAL
- HORIZONTAL
- HEIGHT
- INSIDE DIAMETER
- THAT IS
- INCH(S)
- INCLUDE (ING)
- INSULATION
- INTERIOR
- JOINT
- THOUSAND
- KITCHEN
- KNOCK-OUT
- LENGTH
- LAMINATED
- LAVATORY
- POUND
- LEFT HAND
- LINEAR
- LIGHT
- MILLION
- MASONRY OPENING
- MASONRY
- MAXIMUM
- MECHANICAL
- MEDIUM
- MEZZANINE
- MANUFACTURER
- MINIMUM
- MOULDING
- MODEL
- METAL
- MATERIAL
- MULLION
- NOT APPLICABLE
- NORTH
- NOT IN CONTRACT
- NUMBER
- NOMINAL
- NOT TO SCALE
STUD WIDTH STUD
SPACING
- ON CENTER
- OUTSIDE DIAMETER
- OFFICE
- OVERHEAD
- OWNER FURNISHED
CONTRACTOR INSTALLED
- OPENING
- OPPOSITE HAND
- OUNCE
24"
STUD
SPACING
ALLOW
DEFLECT
L/240
L/360
L/120
L/240
L/360
ALLOW
DEFLECT
25 GAUGE STUD (.0179 MIN.)
16" L/120
L/240
L/360
1-5/8"
24"
L/120
L/240
L/360
16"
L/120
L/240
L/360
2-1/2"
24"
L/120
L/240
L/360
16"
L/120
L/240
L/360
3-5/8"
24"
L/120
PCF
PERP
PL
PLMB
PLWD
PM
POL
POLY
PR
PFB
PFN
PROJ
PSI
PSF
PT
PTD
R
RAD
RD
RECD
REF
REFL
REFG
REINF
REQD
RH
RM
RO
ROW
S
SC
SCHD
SEC
SIM
SP
SPEC
SQ
SS
STD
STL
STOR
STR
SUB
SUSP
SYS
T
TELE
TEMP
T.O.
TYP
UC
UL
UNF
UNO
VB
VCT
VERT
W
W/
W/O
WC
WD
WH
WWM
PARTITION ONE
LAYER
10'-9" f
9'-6" d
8'-3" d
8'-9" f
8'-3" d
7'-3" d
13'-9" f
12'-6" d
10'-9" d
11'-3" f
10'-9" d
9'-6" d
16'-9" f
16'-0" d
14'-0" d
13'-6" f
13'-6" f
12'-3" d
17'-3" f
17'-3" d
15'-0" d
14'-3" f
14'-3" f
13'-0" d
20'-0" f
20'-0" f
20'-0" f
15'-0" v
15'-0" v
15'-0" v
PARTITION ONE
LAYER
15'-3" f
13'-3" d
11'-6" d
12'-6" f
11'-6" d
10'-0" d
19'-6" f
17'-6" f
15'-6" d
16'-0" f
15'-6" f
13'-6" d
23'-6" f
22'-9" d
19'-9" d
19'-3" f
PARTITION TWO
LAYERS
10'-9" f
10'-6" d
9'-0" d
8'-9" f
8'-9" f
8'-0" d
13'-9" f
13'-6" d
11'-9" d
11'-3" f
11'-3" f
10'-3" d
16'-9" f
16'-9" f
14'-9" d
13'-6" f
13'-6" f
13'-0" d
17'-3" f
17'-3" f
15'-9" d
14'-3" f
14'-3" f
13'-9" d
20'-0" f
20'-0" f
20'-0" f
15'-0" v
15'-0" v
15'-0" v
PARTITION TWO
LAYERS
15'-3" f
14'-6" d
12'-9" d
12'-6" f
12'-6" f
11'-0" d
19'-6" f
19'-0" f
16'-6" d
16'-0" f
16'-0" f
14'-6" d
23'-6" f
23'-6" f
21'-3" d
19'-3" f
- POUNDS PER CUBIC FOOT
- PERPENDICULAR
- PLATE
- PLUMBING
- PLYWOOD
- PROJECT MANAGER
- POLISH
- POLYETHYLENE
- PAIR
- PREFABRICATED
- PREFINISHED
- PROJECT
- POUNDS PER SQUARE INCH
- POUNDS PER SQUARE FOOT
- PRESSURE TREATED
- PAINTED
- RISER
- RADIUS
- ROOF DRAIN
- RECEIVED
- REFERENCE
- REFLECTED
- REFRIGERATOR
- REINFORCING
- REQUIRED
- RIGHT HAND
- ROOM
- ROUGH OPENING
- RIGHT OF WAY
- SOUTH
- SOLID CORE
- SCHEDULE
- SECTION
- SIMILAR
- STAND PIPE
- SPECIFICATION
- SQUARE
- STAINLESS STEEL
- STANDARD
- STEEL
- STORAGE
- STRUCTURAL
- SUBSTITUTE
- SUSPENDED
- SYSTEM
- TREAD
- TELEPHONE
- TEMPERED
- TOP OF
- TYPICAL
- UNDER CUT
- UNDERWRITERS LABORATORY
- UNFINISHED
- UNLESS NOTED OTHERWISE
- VAPOR BARRIER
- VINYL COMPOSITION TILE
- VERTICAL
- WEST
- WITH
- WITHOUT
- WATER CLOSET
- WOOD
- WATER HEATER
- WELDED WIRE MESH
FURRING
ONE LAYER
10'-3" d
8'-3" d
7'-3" d
8'-9" f
7'-3" d
6'-3" d
13'-9" d
11'-0" d
9'-9" d
11'-3" f
9'-9" d
8'-6" d
16'-9" f
14'-6" d
12'-9" d
13'-6" f
12'-9" d
11'-0" d
17'-3" f
15'-9" d
13'-9" d
14'-3" f
13'-9" d
12'-0" d
20'-0" f
20'-0" f
18'-9" f
15'-0" v
15'-0" v
15'-0" v
TYPICAL DEVICE MOUNTING
LOCATIONS
NOT TO SCALE
DO NOT LOCATE AA OR SS ON LOGO WALLS.
LEGEND:
AA
SS
W
S
T
V
E
F
DOOR
AUDIBLE ALARM
SAFETY STROBE
WALL PHONE
LIGHT SWITCH
THERMOSTAT
VOICE/DATA
RECEPTACLE
WALL MTD FURNITURE IN-FEED
C L
AA SS
W
S T
E V
F
COLUMN
6"
8"
AFF
1'-6" AFF
10" 6"
AA SS
S T
E V
3'-8" AFF
W
4'-6" AFF
SECURITY DEVICES
NOT TO SCALE
CONDUITS AND PENETRATIONS
SHALL BE DEBURRED FROM ROUGH
EDGES.
42" AFF
CR
KP
10"
DPS
ES
3/4" CONDUIT FROM
JBOX TO DEVICE, TYP.
PT
F
8"
AFF
6'-8" AFF
1'-6" AFF
3'-8" AFF
4'-6" AFF
6'-8" AFF
LEGEND:
CR CARD READER
KP KEYPAD
ES ELECTRIC STRIKE
PT POWER TRANSFER HINGE
DPS DOOR POSITION SWITCH
J 6"X6"X4" JUNCTION BOX
J
1" CONDUIT TO
CABLETRAY PATHWAY
TO IDF ROOM
CEILING
3/4" CONDUIT , TYP.
SCHEDULED FRAME
SCHEDULED DOOR
DOOR LEGEND
WD/DL
A/T6
P3
EX.
EX/PA
WS/PA
DIM
WB/BF
WS/PA
4"
EXISTING DOOR AND FRAME TO REMAIN.
CONTRACTOR SHALL MAKE MINOR ALTERATIONS
AS REQUIRED. REFER TO "DOOR TYPE SCHEDULE".
NEW PROJECT STANDARD DOOR & METAL FRAME.
SEE DOOR TYPE SCHEDULE FOR SPECIFICATIONS.
NEW PROJECT STD. BI-FOLD DOOR. SEE DOOR TYPE
SCHEDULE SPECIFICATIONS. BI-FOLD WIDTH AS NOTED
IN PLANS. JAMB TO BE GYPSUM CASED OPENING.
EXISTING DOOR TO BE REMOVED (USUALLY
DEPICTED IN THE DEMOLITION PLAN).
OPENING TO BE PATCHED WITH PARTITION ASSEMBLY
AND FINISHES EQUAL TO ADJACENT PARTITION
(USUALLY DEPICTED IN THE ARCHITECTURAL PLAN).
ALL DOORS SHOWN AS NEARLY ABUTTING A
PERPENDICULAR WALL WILL BE PLACED 4" FROM
THE CORNER.
NEW DOUBLE DOOR AND METAL FRAME. SEE DOOR
TYPE SCHEDULE FOR SPECIFICATIONS.
INACTIVE LEAF
ACTIVE LEAF
DRAWING LEGEND
NOT TO SCALE. SEE INDIVIDUAL DRAWINGS FOR LEGENDS AND KEYS
THAT SUPERCEDE THOSE BELOW.
100 OFFICE REFERENCE ROOM NUMBER: 100
ROOM NAME: OFFICE
5
COLUMN CENTER LINE
REFERENCE DOOR & HARDWARE TYPE
WS/PA
1
TECHNICAL PARTITION NOTES & DETAILS
TN1. TECHNICAL NOTE
REFER TO THE TYPICAL LIMITING HEIGHTS FOR INTERIOR PARTITIONS AND
CHASE WALL PARTITIONS TABLES AS NEEDED FOR STUD SIZE, GAUGE,
SPACING AND MAXIMUM HEIGHT. STUD GAUGE SHALL BE NO LESS THAN
16; AND SPACING NO LESS THAN 16" ON CENTER. THIS CHART WAS
PROVIDED BY UNITED STATES GYPSUM COMPANY SA923. FOR
INFORMATION ON OTHER MATERIALS, CONSULT AND CONFORM TO
MANUFACTURER'S RECOMMENDED TYPE AND SPACING. THE MAXIMUM
DEFLECTION ALLOWED SHALL BE L/120 UNLESS NOTED OR REQUIRED
OTHERWISE. THE MAXIMUM DEFLECTION ALLOWED FOR WALLS WITH
WALL TILE SHALL BE L/360.
IF THERE IS TO BE AN UNUSUAL LOAD APPLIED TO THE PARTITION, OR
THERE IS UNCERTAINTY ON THE PART OF THE CONTRACTOR, THE
ARCHITECT'S STRUCTURAL ENGINEER SHALL BE CONSULTED. IF THE
ARCHITECT HAS NOT CONTRACTED WITH A STRUCTURAL ENGINEER, THE
CONTRACTOR SHALL CONSULT WITH A STRUCTURAL ENGINEER LICENSED
IN THE STATE WHERE THE PROJECT IS LOCATED.
ALL TECHNICAL PARTITIONS SHALL HAVE A 3" THICK MIN SOUND
ATTENUATION FIBERGLASS BATT INSTALLED CONTINUOUSLY FROM
FLOOR TO TOP OF PARTITION. BATTEN SHALL BE FASTENED IN SUCH A
WAY AS TO PREVENT IT FROM SLIDING DOWN AND LEAVING A VOID AT THE
TOP.
TN2. TECHNICAL NOTE
TAPE AND MUD ALL JOINTS AND SCREWS ABOVE CEILING, TYPICAL. NO
PAINT ABOVE FINISHED CEILING EXCEPT AT PRIVATE SIDE OF TECHNICAL
PARTITION. ON PRIVATE SIDE; PAINT PARTITION BLACK FROM ABOVE
FINISHED CEILING TO UNDERSIDE OF DECK.
NOT TO SCALE
5
T6
2
A
T6
4
5
T6
2
3
EXISTING DOOR TO REMAIN AS IS.
REFERENCE SECTION 5 ON SHEET T6
REFERENCE INTERIOR ELEVATIONS A1
THRU A4 ON SHEET T6
REFERENCE DETAIL 5 ON SHEET T6
REFERENCE ELEVATION A ON SHEET T6
SPOT ELEVATION REFERENCE/ HORIZONTAL
DATUM REFERENCE
REVISION NUMBER
BATT INSULATION
REFERENCE WALL TYPE
TN8. TECHNICAL DETAIL
PUBLIC SIDE
NOT TO SCALE
DRAWING NOTES
THE FOLLOWING NOTES APPLY TO ALL DRAWINGS
1. THE SCALE OF THE DRAWING IS APPROXIMATE. IF A DIMENSION REQUIRED FOR
CONSTRUCTION IS NOT SHOWN ON THE DRAWING, THE CONTRACTOR SHOULD
CONSULT THE ARCHITECT FOR CLARIFICATION.
2. ALL CONSTRUCTION INDICATED AS NEW BUT UNNOTED WILL BE OF THE
STANDARD TYPE.
3. NEW ACOUSTICAL TILE CEILING GRIDS WILL BE LAID OUT TO BE OF A
CONSISTENT SPACING, PATTERN AND HEIGHT THROUGHOUT THE FLOOR SO
THAT THE CEILING GRID CAN BE MAINTAINED DURING TENANT CHANGE.
4. ALL DIMENSIONS ARE GIVEN TO THE NOMINAL FINISH FACE. EQUIPMENT
REQUIRING EXACT CLEARANCES SHOULD BE COORDINATED BY THE
CONTRACTOR.
5. UNLESS OTHERWISE NOTED, INSTALLATION OF DATA, TELEPHONE AND
SECURITY SYSTEMS ARE NOT PART OF THE WORK OF THIS CONTRACT.
6. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR NUMEROUS ITEMS
REQUIRING INTERFACE AND COORDINATION BY THE CONTRACTOR. THE
REFLECTED CEILING SHOWS ONLY THE PATTERN OF THE CEILING GRID.
DIMENSION NOTES
5'-8"
5'-4"
5'-8"
HOLD
PRIVATE SIDE
UNDERSIDE OF DECK
BED OF CONTINUOUS
ACOUSTICAL SEALANT.
EXISTING RUNNER ATTACHED TO
STRUCTURE
(1) EXISTING LAYER 5/8" GYPSUM BOARD
EXISTING METAL STUDS WITH NEW
SOUND ATTENUATION FIBERGLASS BATT
INSULATION FROM FLOOR TO UNDERSIDE
OF DECK ABOVE
LEVEL 2 FINISH
LEVEL 4 FINISH
EXISTING BOTTOM TRACK ON BED OF
CONTINUOUS ACOUSTICAL SEALANT.
FLOOR STRUCTURE
NEW PARTITION, IF UNNOTED TO BE
STANDARD WALL TYPE LISTED IN STANDARD
FINISH AND EQUIPMENT SCHEDULE
EXISTING PARTITION
(2) NEW LAYERS 5/8" GYPSUM BOARD;
STAGGER ALL JOINTS.
TECHNICAL PARTITION TYPES
S50 - 50 STC TECHNICAL PARTITIONS
ICS 705 - TECHNICAL SPECIFICATIONS SOUND GROUP 4
TO CONFORM TO 50 STC MIN. - TEST NUMBER SA-80054
HEIGHT: FLOOR TO UNDERSIDE OF DECK ABOVE WITH SOUND INSULATION. EXISTING
METAL STUDS SHALL BE 25 GAUGE MINIMUM AT 24" ON CENTER. REMOVE GYPSUM
BOARD ON PRIVATE SIDE OF PARTITION TO ALLOW FOR INSTALLATION OF NEW SOUND
INSULATION AND PROVIDE 2 LAYERS OF 5/8" GYPSUM BOARD ON PRIVATE SIDE OF
PARTITION. EXISTING LAYER OF 5/8" GYPSUM BOARD ON PUBLIC SIDE OF PARTITION
SHALL REMAIN. SEE TECHNICAL NOTES TN1 AND TN2. SEE TECHNICAL DETAIL TN8.
S50 - EXISTING PARTITION UPGRADE
NEW PARTITION WITH SOUND
ATTENUATING INSULATION
NEW PARTITION EXTENDING
FROM DECK TO DECK ABOVE
NEW FIRE RATED PARTITION EXTENDING
FROM DECK TO DECK ABOVE
NEW SMOKE BARRIER PARTITION
EXTENDING FROM DECK TO DECK ABOVE
NEW HALF HEIGHT PARTITION SEE PARTITION
TYPES FOR HEIGHT ABOVE FLOOR
EXISTING HALF HEIGHT
PARTITION HEIGHT AS NOTED
EXISTING PARTITION TO BE REMOVED
INDICATES A DIMENSION MEASURED FROM EACH
OUTSIDE FINISH FACE
INDICATES A DIMENSION MEASURED FROM INSIDE
FACE OF ONE WALL TO THE OUTSIDE FACE OF THE
OTHER WALL.
INDICATES THAT THE DIMENSION IS CRITICAL AND
MUST BE HELD.
TYPE "P" PARTITIONS
NOT TO SCALE
PX: INFILL, MATCH ADJ.
EXISTING METAL STUD
PARTITION NOTES & DETAILS
REFER TO THE TYPICAL LIMITING HEIGHTS FOR INTERIOR PARTITIONS AND CHASE
WALL PARTITIONS TABLES FOR STUD SIZE, GAUGE, SPACING AND MAXIMUM
HEIGHT. THIS CHART WAS PROVIDED BY UNITED STATES GYPSUM COMPANY
SA923. FOR INFORMATION ON OTHER MATERIALS, CONSULT AND CONFORM TO
MANUFACTURER'S RECOMMENDED TYPE AND SPACING. THE MAXIMUM
DEFLECTION ALLOWED SHALL BE L/120 UNLESS NOTED OR REQUIRED
OTHERWISE. THE MAXIMUM DEFLECTION ALLOWED FOR WALLS WITH WALL TILE
SHALL BE L/360.
IF THERE IS TO BE AN UNUSUAL LOAD APPLIED TO THE PARTITION, OR THERE IS
UNCERTAINTY ON THE PART OF THE CONTRACTOR, THE ARCHITECT'S
STRUCTURAL ENGINEER SHALL BE CONSULTED. IF THE ARCHITECT HAS NOT
CONTRACTED WITH A STRUCTURAL ENGINEER, THE CONTRACTOR SHALL
CONSULT WITH A STRUCTURAL ENGINEER LICENSED IN THE STATE WHERE THE
PROJECT IS LOCATED.
IF AN EXISTING WALL IS NOTED WITH A WALL TYPE THE CONTRACTOR SHALL
DETERMINE THAT THE EXISTING WALL IS IN ACCORDANCE WITH THE
CONSTRUCTION OF THE WALL TYPE NOTED AND NOTIFY THE ARCHITECT IF THE
EXISTING WALL IS NOT IN ACCORDANCE WITH THE WALL TYPE SPECIFIED
NON-RATED ACOUSTIC PARTITION TYPES SHALL HAVE SOUND ATTENUATION
FIBERGLASS BATTS, SIZED TO FIT THE STUD DEPTH, INSTALLED CONTINUOUSLY
FROM FLOOR TO TOP OF PARTITION. IN PARTITION TYPES THAT TERMINATE AT A
SUSPENDED CEILING, A 48" WIDE ENCAPSULATED FIBERGLASS BATT BLANKET
SHALL BE INSTALLED ON TOP OF CEILING CENTERED OVER THE PARTITION.
ACOUSTIC SEALANT SHALL BE INSTALLED BETWEEN RUNNER AND THE
STRUCTURE BELOW, AND RUNNER AND CEILING ABOVE THE PARTITION. FIRE
RATED ACOUSTIC PARTITION TYPES SHALL HAVE MINERAL WOOL BATTS, SIZED TO
FIT THE STUD DEPTH, INSTALLED CONTINUOUSLY FROM FLOOR TO TOP OF
PARTITION.
PARTITION CONSTRUCTION
TYP. INTERIOR PARTITION TYPE: P3, U.N.O.
GC SHALL VERIFY AND CONFIRM THE EXISTING STUD SIZE, GAUGE AND SPACING
IN USE WITHIN THE TENANT SPACE AND/OR BUILDING. AND SHALL NOTIFY THE
ARCHITECT OF ANY DISCREPANCIES BEFORE FRAMING COMMENCES.
STANDARD GYPSUM BOARD THICKNESS: 1/2"
PERIMETER WALLS/PARTITIONS: GYPSUM BOARD
COLUMN ENCLOSURES: GYPSUM BOARD ENCLOSURE
CEILING/WALL INTERFACE: FAST MASK.
STRUCTURE ABOVE
PARTITION CLIP
SUSPENDED CEILING
SYSTEM
CEILING WALL INTERFACE,
FAST MASK, UNO.
CONTINUOUS TRACK
GYP. BD. ONE LAYER
EACH SIDE, SEE
PARTITION NOTES FOR
TYPICAL TYPE
WALL BASE AS
SCHEDULED
CONTINUOUS FLOOR
TRACK
FINISH FLOOR
MORGAN STATE UNIVERSITY SA+P | 39
ARCHITECT / MEP ENGINEER: CONTRACTOR:
REV. NO. DATE
DESCRIPTION
PROJECT MANAGER:
JBG SMITH
6596 SPRINGFIELD CENTER DRIVE
SPRINGFIELD .VA 22150
571-444-0323
PROJECT:
33215 ROOM CONVERSION
3RD FLOOR
6595 SPRINGFIELD CENTER DRIVE
SPRINGFIELD, VA 22150
DWG NO.
DRAWINGS STANDARDS AND DETAILS
TITLE
LATEST REVISION: ISSUE DATE:
T3
PROJECT FILE SP95-3CCR NAME: -ZT3
SM: PM:
BY:
SBN KLO SR
2024 COPYRIGHT Arium AE, LLC ISSUED FOR 100% REVIEW - DATE: 04-05-2024 - NOT FOR CONSTRUCTION
3K41W
3K41W
3J37W
3H36W
3H36W
3J36W
c
MAR 2023
40 |
CONFERENCE:
241 SQFT/15=
17 PEOPLE
OPEN OFFICE:
993 SQFT/50=
20 PEOPLE
OPEN OFFICE:
2,694 SQFT/50=
54 PEOPLE
CONFERENCE: CONFERENCE:
278 SQFT/15= 264 SQFT/15=
19 PEOPLE 19 PEOPLE
STANDPIPE CONFERENCE:
134 SQFT/15=
9 PEOPLE
CONFERENCE:
148 SQFT/15=
10 PEOPLE
BREAK:
432 SQFT/15=
29 PEOPLE
CONFERENCE:
371 SQFT/15=
25 PEOPLE
CONFERENCE:
208 SQFT/15=
14 PEOPLE
CONFERENCE:
112 SQFT/15=
8 PEOPLE
CONFERENCE:
264 SQFT/15=
19 PEOPLE
HIGH/LOW DRINKING
FOUNTAINS
STANDPIPE
OPEN OFFICE:
6,275 SQFT/50=
126 PEOPLE
DISTANCE TO EXIT: 87'-6"
STORAGE:
291 SQFT/300=
1 PERSON
CONFERENCE:
290 SQFT/15=
20 PEOPLE
W
DISTANCE
TO POINT
OF CHOICE:
32'-4"
STORAGE:
291 SQFT/300=
1 PERSON
EXISTING CONDITIONS:
STORAGE:
290 SQFT/100 = 1 PERSON
HIGH/LOW DRINKING
FOUNTAINS
CONFERENCE:
383 SQFT/15=
26 PEOPLE
STORAGE:
291 SQFT/300=
1 PERSON
STORAGE:
577 SQFT/300=
2 PERSON
OPEN OFFICE:
1,621 SQFT/50=
33 PEOPLE
MAJOR DIAGONAL DISTANCE: 585'-9"
(MIN. EXIT SEPARATION: 145'-8")
STORAGE:
340 SQFT/300=
2 PERSON
DOOR SEPARATION: 393'-6"
OPEN OFFICE:
1,091 SQFT/50 =
22 PEOPLE
STORAGE:
119 SQFT/300=
1 PERSON
STORAGE:
118 SQFT/300=
1 PERSON
STANDPIPE
HIGH/LOW DRINKING
FOUNTAINS
STORAGE:
393 SQFT/300=
2 PERSON
CONFERENCE:
231 SQFT/15=
16 PEOPLE
PLAN
NORTH
CONFERENCE:
215 SQFT/15=
15 PEOPLE
CONFERENCE:
251 SQFT/15=
17 PEOPLE
CONFERENCE:
112 SQFT/15=
8 PEOPLE
CONFERENCE:
133 SQFT/15= 9
PEOPLE
BREAK:
433 SQFT/15=
29 PEOPLE
NOT TO SCALE
CRITICAL DIMENSIONS SHALL NOT BE SCALED
EXISTING CONDITIONS HAVE BEEN PARTIALLY
FIELD VERIFIED BY ARIUM AE.
NEW WORK OCCUPANT LOAD CALCULATION:
TOTAL PLUMBING FIXTURE CALCULATIONS:
CONFERENCE:
395 SQFT/15=
27 PEOPLE
STANDPIPE
USE AREA # OF OCCUPANTS
B- UNCONCENTRATED 44,215 SQ FT/ 150 295 PEOPLE
B- CONCENTRATED 18,411 SQ FT/ 50 406 PEOPLE
A- CONFERENCE 4,144 SQ FT/ 15 278 PEOPLE
A- BREAK AREA 865 SQ FT/ 15 58 PEOPLE
S- STORAGE 2,420 SQ FT/ 300 10 PEOPLE
TOTAL: 70,055 SQ FT 1047 PEOPLE
EGRESS PLAN
ARCHITECTURAL
OPEN OFFICE:
5,737 SQFT/50=
115 PEOPLE
3' 12'
0 6' 2'
2018 IPC - TABLE & SECTION 403.1
2018 IPC - SECTION 403.3 - NUMBER PER GENDER - 50% SEPARATION
2018 IPC - SECTION 410.1 - SUBSTITUTION. WHERE RESTAURANTS PROVIDE DRINKING WATER IN A CONTAINER FREE OF CHARGE, DRINKING FOUNTAINS SHALL NOT BE
REQUIRED IN THOSE RESTAURANTS. IN OTHER OCCUPANCIES WHERE DRINKING FOUNTAINS ARE REQUIRED, WATER DISPENSERS SHALL BE PERMITTED TO BE
SUBSTITUTED FOR NOT MORE THAN 50 PERCENT OF THE REQUIRED NUMBER OF DRINKING FOUNTAINS.
WATER CLOSETS LAVATORIES DRINKING FOUNTAINS
USE LOAD RATIO
MALE RATIO FEMALE
BUSINESS
ASSEMBLY
STORAGE
SUBTOTALS
REQUIRED TOTALS
PROVIDED TOTALS
701/ 2
= 351
10/ 2
= 5
1 PER 25 FOR THE
FIRST 50 AND 1
PER 50 FOR THE
REMAINDER
EXCEEDING 50
LEGEND
UNCONCENTRATED BUSINESS
CONCENTRATED BUSINESS
ASSEMBLY
STORAGE
RATIO
MALE
FEMALE
RATIO
8.02
1 PER 25 FOR THE
FIRST 50 AND 1
PER 50 FOR THE
REMAINDER
EXCEEDING 50
8.02
1 PER 40 FOR THE
FIRST 80 AND 1
PER 80 FOR THE
REMAINDER
EXCEEDING 80
5.39 5.39 1 / 100
1 / 100 0.05 1 / 100 0.05
1 / 100
0.05 0.05 1 / 1000
DRINKING
FOUNTAINS
336/ 2
= 168 1 / 125 1.34 1 /65 2.58
1 / 200
0.84 0.84 1 / 500 0.67
9.41 10.65 6.28 6.28
7.69
10 11 7 7 8
17 17 8
8
7.01
0.01
6 + 2 WATER
DISPENSER
ARCHITECT / MEP ENGINEER: CONTRACTOR:
REV. NO. DATE
DESCRIPTION
PROJECT MANAGER:
JBG SMITH
6596 SPRINGFIELD CENTER DRIVE
SPRINGFIELD .VA 22150
571-444-0323
PROJECT:
33215 ROOM CONVERSION
3RD FLOOR
6595 SPRINGFIELD CENTER DRIVE
SPRINGFIELD, VA 22150
TITLE
PROJECT FILE NAME: LATEST REVISION: ISSUE DATE:
SP95-3CCR -ZT4
SM: PM:
BY:
SBN SR KLO
2024
COPYRIGHT Arium AE, LLC MORGAN STATE UNIVERSITY SA+P | 41
DWG NO.
T4
ISSUED FOR 100% REVIEW - DATE: 04-05-2024 - NOT FOR CONSTRUCTION
c
MAR 2023
PLAN
NORTH
42 |
0
CIRCULATION
3K41W
1'
FLR BAS
EX RB
WAL
CLG
PE EX
2' 4'
SCALE 1/4" = 1' - 0"
CRITICAL DIMENSIONS SHALL NOT BE SCALED
EXISTING CONDITIONS HAVE BEEN PARTIALLY
FIELD VERIFIED BY ARIUM AE.
EXTENT OF WORK
CONFERENCE ROOM
3J37W
3K41W CIRCULATION
8'
FLR BAS WAL CLG
CT RB PE EX
W
FINISH PLAN
ARCHITECTURAL
OFFICE
3H36W
OFFICE
3H36W
COPY
3J36W
PLAN
NORTH
0
1'
CIRCULATION
3K41W
2' 4'
SCALE 1/4" = 1' - 0"
CRITICAL DIMENSIONS SHALL NOT BE SCALED
EXISTING CONDITIONS HAVE BEEN PARTIALLY
FIELD VERIFIED BY ARIUM AE.
EXTENT OF WORK
NEW LINEAR
FIXTURE TO
MATCH EXISTING
EXISTING CEILING
TO REMAIN
ADJUST PERIMETER
CEILING TRIM AND TILE
WITH NEW FULL HEIGHT
PARTITIONS.
CONFERENCE ROOM
3J37W
3K41W CIRCULATION
8'
OFFICE
3H36W
REFLECTED CEILING PLAN
ARCHITECTURAL
OFFICE
3H36W
COPY
3J36W
NOTE: THIS DRAWING ILLUSTRATES THE LOCATION OF THE CEILING GRID TO BE CONSTRUCTED UNDER THIS CONTRACT.
PORTIONS OF THE CEILING GRID, AND OTHER CEILING COMPONENTS, MAY ALREADY BE IN PLACE. THE CONTRACTOR SHALL
VISIT THE SITE PRIOR TO SUBMITTING A BID TO BECOME FAMILIAR WITH THE WORK TO BE UNDERTAKEN. FINAL GRID
PLACEMENT WILL COORDINATE WITH EXISTING COMPONENTS REQUIRED TO REMAIN. REFER TO THE "STANDARD FINISHES
AND EQUIPMENT SCHEDULE" OR THE "FINISH SCHEDULE" FOR THE SPECIFICATIONS FOR THE CEILING SYSTEM FINISH.
PLAN
NORTH
CIRCULATION
3K41W
0
1'
EXTENT OF WORK
2' 4'
SCALE 1/4" = 1' - 0"
REMOVE EXISTING LIGHT
FIXTURE IN
PREPARATION FOR NEW
WORK
REMOVE FIRE EXISTING
RATED DOOR, FRAME,
HARDWARE & ASSOCIATED
PARTS.OFFER TO PM PRIOR
TO DISPOSAL
CONFERENCE ROOM
3J37W
3K41W CIRCULATION
CRITICAL DIMENSIONS SHALL NOT BE SCALED
EXISTING CONDITIONS HAVE BEEN PARTIALLY
FIELD VERIFIED BY ARIUM AE.
8'
OFFICE
3H36W
DEMOLITION PLAN
ARCHITECTURAL
NOTE: DOORS, FRAMES, PARTITIONS AND MISCELLANEOUS ITEMS ARE TO BE REMOVED AS DESIGNATED
IN THE DEMOLITION PLAN. THE CONTRACTOR SHALL VERIFY WITH THE PROJECT MANAGER ANY ITEMS
OR EQUIPMENT WHICH SHALL BE SALVAGED FOR POSSIBLE REUSE IN THE PROJECT OR ELSEWHERE.
REFER TO MECHANICAL/ELECTRICAL DOCUMENTS FOR RELATED DEMOLITION.
OFFICE
3H36W
COPY
3J36W
EX.
EX.
PLAN
NORTH
0
CIRCULATION
3K41W
1'
2' 4'
SCALE 1/4" = 1' - 0"
EXTENT OF WORK
EX.
1
S50
S50
CRITICAL DIMENSIONS SHALL NOT BE SCALED
EXISTING CONDITIONS HAVE BEEN PARTIALLY
FIELD VERIFIED BY ARIUM AE.
S50
COORDINATE EXISTING
EYEWASH WITH NEW
PARTITION. EXTEND PIPES
AND REHANG IF NECESSARY.
CONFERENCE ROOM
3J37W
3K41W CIRCULATION
8'
2
W
3'-3"
S50
S50
FLOOR PLAN
ARCHITECTURAL
MORGAN STATE UNIVERSITY SA+P | 43
OFFICE
3H36W
OFFICE
3H36W
COPY
3J36W
ARCHITECT / MEP ENGINEER: CONTRACTOR:
REV. NO. DATE
DESCRIPTION
PROJECT MANAGER:
JBG SMITH
6596 SPRINGFIELD CENTER DRIVE
SPRINGFIELD .VA 22150
571-444-0323
PROJECT:
33215 ROOM CONVERSION
3RD FLOOR
6595 SPRINGFIELD CENTER DRIVE
SPRINGFIELD, VA 22150
DWG NO.
TITLE
T5 PROJECT FILE NAME: LATEST REVISION: ISSUE DATE:
SP95-3CCR -ZT5
SM: PM:
BY:
COPYRIGHT 2024
Arium AE, LLC SBN KLO SR
ISSUED FOR 100% REVIEW - DATE: 04-05-2024 - NOT FOR CONSTRUCTION
E1 COVER SHEET - ELECTRICAL GB GB
GB
ELECTRICAL SPECIFICATIONS
GENERAL REQUIREMENTS:
1. INSTALLATION STANDARDS AND PRACTICES
A. COORDINATE AND COMPLY WITH SPECIFICATIONS AND REQUIREMENTS IN ARCHITECTURAL
PLANS, MECHANICAL PLANS AND IN CONTRACT FOR CONSTRUCTION.
B. FURNISH ALL LABOR, EQUIPMENT, SUPPLIES AND MATERIALS AND PERFORM ALL OPERATIONS
INCLUDING EXCAVATIONS AND BACK FILLING, CUTTING, CHANNELING AND CHASING NECESSARY
FOR THE INSTALLATION OF COMPLETE SYSTEMS.
C. PERFORM ALL WORK IN ACCORDANCE WITH THE RULES AND REGULATIONS OF ALL APPLICABLE,
MUNICIPAL, STATE, AND OTHER LOCAL CODES, AND THE VERSION OF THE NATIONAL ELECTRICAL
CODE ADOPTED BY THE JURISDICTION.
D. ALL WORK SHALL BE PERFORMED IN A WORKMANLIKE MANNER, IN CONFORMANCE WITH
MANUFACTURER'S INSTALLATION RECOMMENDATIONS AND INDUSTRY PRACTICES.
E. PROCURE ALL NECESSARY PERMITS, LICENSES AND INSPECTIONS AND PAY ALL FEES AND
CHARGES.
F. COORDINATE AND SCHEDULE SHUTDOWNS OF ELECTRIC SERVICE, FEEDERS AND CIRCUITS
AROUND THE NEEDS OF THE OWNER OF THE FACILITY.
G. PROVIDE TEMPORARY POWER AS REQUIRED FOR CONSTRUCTION.
H. THE GENERAL ARRANGEMENT OF CONDUIT, WIRING AND EQUIPMENT SHALL BE AS SHOWN ON
THE CONTRACT DRAWINGS, WITHOUT SUBSTANTIAL ALTERATION. THE DRAWINGS ARE
GENERALLY DIAGRAMMATIC AND DUE TO THE SMALL SCALE OF THE DRAWINGS, ALL OFFSETS,
FITTINGS AND ACCESSORIES ARE NOT INDICATED. ENGINEER AND OWNER RESERVE THE RIGHT
TO MAKE REASONABLE CHANGES IN LOCATION OF DEVICES, EQUIPMENT, AND ROUTING OF
CONDUIT, UP TO THE TIME OF ROUGHING-IN AT NO ADDITIONAL COST.
I. THE CONTRACTOR SHALL VISIT THE SITE AND OBSERVE EXISTING CONDITIONS INCLUDING
STRUCTURAL, FINISH AND OTHER CIRCUMSTANCES THAT AFFECT THE COMPLETION OF THE
WORK. ACCOMMODATE WORK ACCORDINGLY AT NO ADDITIONAL COST TO THE OWNER.
J. REFER TO MECHANICAL PLANS FOR EXACT LOCATIONS OF MECHANICAL EQUIPMENT AND
CONTROL WIRING REQUIREMENTS. IN GENERAL, CONTROL AND INTERLOCK WIRING FOR HVAC
SYSTEMS IS UNDER DIVISION 15. CONTRACTOR SHALL CAREFULLY REVIEW THE CONTRACT
DOCUMENTS AND COORDINATE EXCLUSIONS WITH OTHER TRADES.
K. REMOVE ALL LIGHTING FIXTURES, RECEPTACLES, ETC., IN THE EXISTING SPACE THAT INTERFERE
WITH THE NEW CONSTRUCTION AND AS SHOWN ON THE DRAWINGS. REMOVE ALL CONDUCTORS
BACK TO THE CLOSEST ACCESSIBLE JUNCTION POINT. MAINTAIN CONTINUITY OF CIRCUITRY TO
ANY DEVICES WHICH ARE TO REMAIN AS PART OF A NON-AFFECTED WALL OR PARTITION.
CONTRACTOR SHALL CONFIRM WITH OWNER WHETHER OR NOT REMOVED LIGHTS ARE TO BE
TURNED OVER TO OWNER STOCK.
L. INDIVIDUAL HOME RUNS ARE SHOWN FOR CLARITY ONLY. E.C. CAN COMBINE THEM TOGETHER
PER N.E.C. MULTIWIRE CIRCUITS WITH COMMON NEUTRALS SHALL HAVE BREAKER HANDLE TIES.
M. THE CONTRACTOR SHALL STUDY THE ARCHITECTURAL AND ELECTRICAL DRAWINGS AND
COORDINATE EXACT LOCATIONS OF THE VARIOUS ELECTRICAL DEVICES WITH DOOR SWINGS,
GLASS PARTITIONS, ETC.
N. MANUFACTURERS AND MODEL NUMBERS INDICATED ON THE CONTRACT DRAWINGS SHALL BE
FOR REFERENCE AND BASIS OF DESIGN ONLY. VERIFY ALL EQUIPMENT REQUIREMENTS,
PERFORMANCE STANDARDS AND ACCESSORIES PRIOR TO ORDERING OF EQUIPMENT. ARIUM
SHALL TAKE NO RESPONSIBILITY FOR EQUIPMENT THAT IS IMPROPERLY ORDERED OR INSTALLED.
O. ANY EXISTING FEEDERS THAT ARE REUSED OR MODIFIED AS A RESULT OF THE CONTRACT
DRAWINGS SHALL BE FIELD VERIFIED BY THE CONTRACTOR PRIOR TO BIDDING. WAIVER OF
RESPONSIBILITY OR REQUESTS FOR ADDITIONAL PAYMENT BASED ON LACK OF KNOWLEDGE OF
CONDITIONS AT THE SITE WILL NOT BE ACCEPTED.
P. IN AREAS WITH OPEN CEILINGS; CONTRACTOR SHALL WORK TO SUPPORT EXISTING TO REMAIN
CABLES AND WIRING TO STRUCTURE TO CREATE A TIDY APPEARANCE.
2. SUBMITTALS:
A. THE CONTRACTOR SHALL PREPARE AND SUBMIT CATALOG CUTS, SPECIFICATION SHEETS,
DESCRIPTIVE DATA, ETC., FOR PANELBOARDS, DISCONNECT SWITCHES, WIRING DEVICES, WIRE
AND CABLE, RACEWAY, FA EQUIPMENT AND ALL OTHER EQUIPMENT AND MATERIALS SPECIFIED.
B. PREPARE AND SUBMIT SHOP DRAWINGS AND/OR DIAGRAMS FOR ALL SPECIALLY FABRICATED
ITEMS, MODIFICATIONS TO STANDARD ITEMS AND SYSTEMS WHERE DETAILED DESIGN IS NOT
SHOWN ON THE CONTRACT DRAWINGS OR WHERE THE PROPOSED INSTALLATION DIFFERS FROM
THAT SHOWN ON THE CONTRACT DRAWINGS. SHOP DRAWINGS SHALL INCLUDE PLANS,
ELEVATIONS, SECTIONS, MOUNTING DETAILS OF COMPONENT PARTS, POINT TO POINT
INTERCONNECTIONS DIAGRAMS, SINGLE LINE DIAGRAMS AND OTHER DRAWINGS NEEDED TO
FULLY DESCRIBE THE FUNCTION, FABRICATION AND CONNECTION OF THE SYSTEM.
3. CUTTING AND PATCHING: ALL CUTTING AND PATCHING NECESSARY FOR THE INSTALLATION OF THE
ELECTRICAL WORK SHALL BE DONE BY THE ELECTRICAL CONTRACTOR. ANY DAMAGE DONE TO THE
WORK ALREADY IN PLACE BY REASON OF THIS WORK SHALL BE REPAIRED AT THE CONTRACTOR'S
EXPENSE. PATCHING SHALL BE UNIFORM IN APPEARANCE AND SHALL MATCH WITH THE SURROUNDING
SURFACE.
4. IDENTIFICATION: PERMANENTLY IDENTIFY ALL MOTOR STARTERS, DISCONNECT SWITCHES, CONTROLS,
PANELBOARDS, TERMINAL BOARDS, TRANSFORMERS AND OTHER EQUIPMENT IN ACCORDANCE WITH
THE PROJECT NOMENCLATURE. IDENTIFICATION PLATES SHALL BE LAMINATED PLASTIC, BLACK WITH
WHITE ENGRAVED LETTERS. UNLESS OTHERWISE, INDICATED, USE ¼" HIGH LETTERING. LETTERING
FOR CONTROL CENTERS, CONTROL PANELS, METERING AND INSTRUMENT PANELS SHALL BE 3/8" HIGH.
ATTACH IDENTIFICATION PLATES WITH CORROSION RESISTANT PHILLIPS HEAD STEEL SCREWS OR
ADHESIVE APPROVED FOR THE PURPOSE.
5. HAZARDOUS MATERIALS: ENGINEER HAS NOT INVESTIGATED OR MADE ANY CONSIDERATION FOR THE
POSSIBLE PRESENCE OF HAZARDOUS MATERIALS. IN THE EVENT THAT CONTRACTOR DISCOVERS
POTENTIAL OR PRESUMED HAZARDOUS MATERIALS, THE OWNER SHALL BE IMMEDIATELY NOTIFIED AND
SUCH MATERIALS SHALL NOT BE DISTURBED PENDING DIRECTION FROM OWNER.
6. RECORD DRAWINGS: UPON COMPLETION OF THE ELECTRICAL INSTALLATION, THE CONTRACTOR SHALL
DELIVER TO THE OWNER ONE (1) SET OF PRINTS OF THE ELECTRICAL CONTRACT DRAWINGS WHICH
SHALL BE LEGIBLY MARKED IN ERASABLE RED PENCIL TO SHOW ALL CHANGES AND DEPARTURES OF
THE INSTALLATION AS COMPARED WITH THE ORIGINAL DESIGN. THEY SHALL BE SUITABLE FOR USE IN
PREPARATION OF RECORD DRAWINGS.
7. TESTS: FURNISH ALL LABOR, MATERIALS, INSTRUMENTS, FUEL AND POWER REQUIRED TO PERFORM
ALL NECESSARY TESTS. PERFORM TESTS ACCORDING TO NEMA STANDARDS. ALL DEFECTIVE
MATERIALS AND/OR WORKMANSHIP DISCOVERED AS A RESULT OF TESTS SHALL BE REPLACED AT NO
EXPENSE TO THE OWNER AND THE TEST SHALL BE REPEATED. A THOROUGH TEST SHALL BE MADE TO
DEMONSTRATE THAT THE SYSTEM IS FREE FROM GROUND FAULTS, SHORT CIRCUITS, AND OPEN
CIRCUITS; THAT THE RESISTANCE TO GROUND OF ALL NON-GROUNDED CIRCUITS, BEFORE AND AFTER
CONNECTION OF EQUIPMENT MEETS THE REQUIREMENTS OF THE NEC.
8. GUARANTEE: THE MATERIAL AND WORKMANSHIP OF ALL PARTS OF THE ELECTRICAL INSTALLATION
SPECIFIED HEREIN SHALL BE GUARANTEED UNCONDITIONALLY FOR A PERIOD OF ONE (1) YEAR FROM
DATE OF ACCEPTANCE AGAINST MECHANICAL AND ELECTRICAL DEFECTS ARISING FROM FAULTY
MATERIALS OR WORKMANSHIP. EITHER REPLACEMENT OR REPAIRS SHALL BE MADE PROMPTLY ON ANY
DEFECTIVE MATERIALS OR WORKMANSHIP WITHOUT CHARGE DURING THAT PERIOD.
ELECTRICAL MATERIALS AND METHODS:
1. MATERIALS - GENERAL:
A. ALL MATERIALS SHALL BE NEW AND SUITABLE FOR THE CONDITIONS AND DUTIES IMPOSED ON THEM
AFTER INSTALLATION. ALL SUCH MATERIAL SHALL BE AS FOUND IN THE APPROVED LIST OF THE
NATIONAL BOARD OF FIRE UNDERWRITERS. ALL EQUIPMENT AND SYSTEMS SHALL BE UL APPROVED.
B. WHERE MATERIAL OR EQUIPMENT IS IDENTIFIED BY PROPRIETARY NAME, MODEL NUMBER AND /OR
MANUFACTURER, FURNISH THE ITEM OR EQUAL THEREOF, SUBJECT TO ACCEPTANCE BY THE ENGINEER.
SUBSTITUTED ITEMS SHALL BE EQUAL OR BETTER IN QUALITY AND PERFORMANCE AND MUST BE
SUITABLE FOR THE AVAILABLE SPACE, REQUIRED ARRANGEMENT AND APPLICATION. SUBMIT ANY AND
ALL DATA NECESSARY TO DETERMINE THE SUITABILITY OF SUBSTITUTED ITEMS.
2. CONDUITS AND FITTINGS:
A. GENERAL:
a. INSTALL ALL WIRING IN METAL RACEWAY, PROVIDE CABLES AND PROVIDE EMPTY CONDUIT FOR
SPECIAL SYSTEMS DESCRIBED ELSEWHERE.
b. MINIMUM CONDUIT SIZE SHALL BE 3/4" AND 1" FOR UNDERGROUND CONDUITS.
c. IN FINISHED AREAS, INSTALL ALL RACEWAYS CONCEALED UNLESS OTHERWISE INDICATED. IF MC
CABLE IS BUILDING STANDARD AND PERMITTED BY CODE, IT MAY BE USED FOR NEW CONCEALED
BRANCH CIRCUITS (LESS THAN 60 A).
d. BRANCH CIRCUITS SHALL BE RUN IN CONDUIT IN ALL AREAS WHERE THEY CANNOT BE
CONCEALED. THESE SHALL INCLUDE, BUT NOT BE LIMITED TO, OPEN CEILINGS, UNFINISHED WALLS,
MECHANICAL EQUIPMENT SPACES, ETC. EXPOSED CONDUIT SHALL BE RUN PLUMB. AND PARALLEL
OR PERPENDICULAR TO THE WALLS IN A NEAT AND ORDERLY MANNER USING EVENLY SPACED
HANGERS.
e. FOR HAZARDOUS LOCATIONS, PENETRATION OF EXTERIOR WALLS AND OTHER PARTITIONS WITH
HIGH TEMPERATURE/HUMIDITY DIFFERENTIALS SUCH AS THOSE FOR COLD STORAGE, PROVIDE
COMPOUND FILLED SEALING FITTINGS.
f. ALL CONDUITS WITH A NOMINAL DIAMETER OF 2 INCHES OR LARGER SHALL BE RIGID METAL
CONDUIT.
B. MATERIALS:
a. PROVIDE HOT-DIP GALVANIZED, RIGID STEEL CONDUIT FOR WORK EXPOSED TO WEATHER AND
FOR EMBEDDED WORK IN CONCRETE OR MASONRY AND IN OR BELOW THE CONCRETE SLAB ON
GRADE (ABOVE THE VAPOR BARRIER). USE THREADED FITTINGS W/DBL LOCKNUTS & INSULATED
BUSHINGS.
b. PROVIDE LIQUIDTIGHT FLEXIBLE CONDUIT (SEALTIGHT) FOR CONNECTION TO EXTERIOR & KITCHEN
EQUIPMENT.
c. PROVIDE GALVANIZED EMT WITH COMPRESSION FITTINGS UNLESS OTHERWISE NOTED.
C. SUPPORTS:
a. ALL SUPPORT PARTS AND HARDWARE SHALL BE GALVANIZED.
b. SUPPORT ALL RACEWAYS SO THAT STRAIN IS NOT TRANSMITTED TO OUTLET BOXES AND PULL
BOXES, ETC. SUPPORTS SHALL BE SUFFICIENTLY RIGID TO PREVENT DISTORTION OF CONDUITS
DURING WIRE PULLING.
c. SUPPORT SINGLE RUNS OF SUSPENDED FEEDER CONDUIT WITH "KINDORF" D-149 OR C-150
ADJUSTABLE HANGERS USING 3/8" RODS FOR CONDUITS UP TO 2" AND 1/2" RODS FOR CONDUITS
LARGER THAN 2".
d. SUPPORT GROUPS OF SUSPENDED CONDUITS RUN IN PARALLEL ON TRAPEZE HANGERS
CONSTRUCTED OF "KINDORF" CHANNELS WITH C-105 CONDUIT STRAPS AND SUSPENDED WITH 1/2"
HANGER RODS. NO TIE WIRES OR BUILDING WIRE SHALL BE USED FOR STRAPPING CONDUITS.
e. SUPPORT SURFACE RUNS OF CONDUIT USING ONE HOLD PIPE STRAP OR TWO HOLD PIPE STRAPS.
STRAP SPACING MAXIMUM 6 FT. ON CENTERS.
f. FASTEN PIPE STRAPS AND HANGERS TO CONCRETE USING INSERTS OR EXPANSION BOLTS AND TO
HOLLOW MASONRY USING TOGGLE BOLTS. WOODEN PLUGS AND SHIELDS SHALL NOT BE
PERMITTED. ALL SUPPORTS IN BAR JOISTS CONSTRUCTION SHALL BE ATTACHED TO THE TOP
CHORD OF THE JOISTS USING SUITABLE CLAMPS APPROVED FOR THE PURPOSE.
g. SUPPORT CONDUITS FROM JOISTS AND BEAMS USING CLAMPS AND /OR CADDY CLIPS APPROVED
FOR THE PURPOSE.
3. BOXES
A. OUTLET BOXES FOR CONCEALED WORK SHALL BE ZINC-COATED SHEET STEEL NOT LESS THAN 4"
OCTAGONAL OR SQUARE AND SUITABLE FOR SERVICE AND TYPE OF DEVICE. BOXES FOR OUTDOOR
WORK SHALL BE NEMA 3R CAST ALUMINUM BOXES WITH GASKETED JOINTS, THREADED HUBS FOR
CONDUIT ENTRY AND CORROSION RESISTANT FINISH.
B. OUTLET BOXES IN EXPOSED MASONRY WALLS SHALL BE PROVIDED WITH DEEP SQUARE-CUT DEVICE
COVERS. THEY SHALL BE SET SO THAT THE BRICK OR BLOCK CAN BE CUT AND FITTED CLOSELY TO THE
COVER OPENING AND SO THAT THE STANDARD WALL PLATE WILL COVER THE JOINT BETWEEN THE
BRICK OR BLOCK AND THE BOX.
C. ALL BOXES USED FOR SUPPORTING FIXTURES SHALL BE FURNISHED WITH MALLEABLE IRON FIXTURE
STUDS OF "NO-BOLT" TYPE SECURED BY LOCKNUT. PROVIDE SUPPORT FOR BOXES INDEPENDENT OF
SUSPENDED CEILINGS.
D. JUNCTION AND PULL BOXES SHALL BE FURNISHED AND INSTALLED AS SHOWN OR WHERE REQUIRED TO
FACILITATE PULLING OF WIRES AND CABLES. SUCH BOXES SHALL BE INSTALLED IN ACCESSIBLE
LOCATIONS. ALL BOXES FOR CONCEALED WORK SHALL BE CONSTRUCTED OF 12 GAUGE GALVANIZED
SHEET STEEL UNLESS OTHERWISE NOTED AND SHALL BE PROVIDED WITH MOUNTING BRACKETS AND
FLAT SCREW COVERS. BOXES FOR EXTERIOR WORK SHALL BE CAST ALUMINUM OR GALVANIZED CAST
IRON WITH THREADED HUBS AND GASKETED COVERS.
4. WIRE AND CABLE (600 VOLT):
A. BUILDING WIRE, UNLESS OTHERWISE INDICATED, SHALL BE 600 VOLT, TYPE THHN AND THWN
INSULATION FOR INTERIOR USE AND TYPE USE, CROSS-LINKED POLYETHYLENE INSULATION FOR
UNDERGROUND OUTSIDE BUILDING INSTALLATION. CONDUCTORS SHALL BE SIZED AND RUN AS
INDICATED. CONDUCTORS SHALL BE SOFT DRAWN COPPER OF NOT LESS THAN 98% CONDUCTIVITY.
B. NO WIRE SMALLER THAN NUMBER TWELVE (12) AWG SHALL BE USED UNLESS OTHERWISE INDICATED.
THE WIRE SIZE INDICATED IN THE HOMERUN SHALL BE USED THROUGHOUT THE CIRCUIT. CONDUCTORS
SHALL BE CONTINUOUS FROM OUTLET TO OUTLET AND FROM TERMINAL BOARD TO POINT OF FINAL
CONNECTION, AND NO SPLICE SHALL BE MADE EXCEPT WITHIN OUTLET OR JUNCTION BOXES. ALL WIRES
NUMBER EIGHT (8) AWG AND LARGER SHALL BE STRANDED AND SPLICES SHALL BE OF THE TYPE
INDENTED INTO CONDUCTOR.
C. A COLOR CODING SYSTEM SHALL BE USED FOR THROUGHOUT THE BUILDING'S NETWORK OF FEEDERS
AND CIRCUITS. SELECTION SHALL BE BASED ON APPLICABLE WORK COVERED BY THIS CONTRACT.
D. ALL CONTROL WIRING SHALL BE COLOR CODED WITH WIRES OF COLORS DIFFERENT FROM THOSE TO
DESIGNATE PHASE WIRES.
5. WIRING DEVICES:
A. ALL DEVICES SHALL BE OF THE SAME MANUFACTURER. DEVICES SHALL BE GENERAL ELECTRIC,
HUBBELL, ARROW HART, LEVITON OR APPROVED EQUAL.
B. WALL SWITCHES: TOGGLE SWITCHES SHALL BE OF THE SILENT MECHANICAL TYPE RATED 20 AMPERE,
RATED FOR SUPPLIED VOLTAGE. MOUNT SWITCHES 3'-8" TO CENTER OF OUTLET BOX ABOVE FLOOR.
C. RECEPTACLES: RECEPTACLES FOR WALL OUTLETS SHALL BE NEMA 5-20R, 125 VOLTS, DUPLEX,
THREE-WIRE WITH THIRD POLE GROUNDED. VERIFY EXISTING OUTLET LOCATIONS PRIOR TO ROUGH-IN
OF NEW. MOUNT RECEPTACLES 18" ABOVE FINISHED FLOOR (UNLESS OTHERWISE NOTED).
D. GROUND, PHASE AND NEUTRAL CONDUCTORS SHALL BE PIGTAILED IN OUTLET BOXES OR MULTI-OUTLET
ASSEMBLY FOR RECEPTACLES SO THAT GROUND AND ELECTRICAL SERVICE WILL NOT BE DISTURBED TO
OTHER RECEPTACLES ON THE SAME MULTI-WIRE CIRCUIT IF RECEPTACLE IS REMOVED.
E. DEVICE PLATES: A DEVICE PLATE SHALL BE PROVIDED FOR EACH OUTLET REQUIRING ONE. ALL PLATES
SHALL BE APPROVED BY THE ARCHITECT.
F. GFCI RECEPTACLES: GFCI RECEPTACLES SHALL BE STRAIGHT-BLADE, NON-FEED THRU, DUPLEX TYPE
RECEPTACLE WITH INTEGRAL GROUND FAULT PROTECTION AND RATED FOR 20A, 120V.
G. USB RECEPTACLES: USB RECEPTACLES SHALL BE STRAIGHT-BLADE, NON-FEED THRU, DUPLEX TYPE
RECEPTACLE WITH (2) INTEGRAL USB PORTS AND RATED FOR 20A, 120V.
H. REFER TO ARCHITECTURAL DRAWINGS FOR COLOR OF WIRING DEVICE AND DEVICE PLATE UNLESS
OTHERWISE NOTES.
I. EXISTING WIRING DEVICES AND WALL PLATES SHALL BE REPLACED AS REQUIRED TO MATCH NEW.
J. MOTOR RATED SWITCH:MOTOR RATED SWITCH SHALL BE FOR SINGLE PHASE MOTORS RATED 1 HP AND
LESS. SWITCH SHALL HAVE A QUICK-MAKE/QUICK-BREAK TOGGLE SWITCH MECHANISM. ENCLOSURE
SHALL BE A GENERAL PURPOSE NEMA 1 ENCLOSURE, UNLESS OTHERWISE INDICATED. MANUAL MOTOR
STARTER SHALL BE MANUFACTURED BY CUTLER HAMMER, GENERAL ELECTRIC, SIEMENS OR SQUARE D.
K. RECEPTACLES THAT ARE AUTOMATICALLY CONTROLLED TO REMOVE POWER FOR ENERGY
MANAGEMENT OR BUILDING AUOMATION MUST BE PERMANENTLY MARKED WITH THE WORD
"CONTROLLED" AND HAVE A VISIBLE POWER SYMBOL ON THE RECEPTACLE.
6. GROUNDING:
A. PROVIDE EQUIPMENT GROUNDING CONDUCTORS WHERE INDICATED IN ALL RACEWAYS AND CABLES
SIZED IN ACCORDANCE WITH THE N.E.C.
B. PROVIDE GROUNDING ELECTRODE CONDUCTOR CONNECTED TO THE BUILDING GROUNDING SYSTEM
FOR TRANSFORMER SECONDARY.
7. FIRESTOPPING NOTES:
A. PROVIDE AND INSTALL COMPLETE PENETRATION FIRESTOPPING SYSTEM THAT CONFORMS WITH ASTM E
814 AND UL 1479. SYSTEM SHALL CONFORM TO CONSTRUCTION TYPE, PENETRANT TYPE, ANNULAR
SPACE REQUIREMENTS AND FIRE RATING.
B. ALL CORE DRILL OPENINGS FOR ELECTRICAL AND COMMUNCIATION CONDUITS THROUGH FLOOR SLAB
SHALL BE FIRESTOPPED SUCH THAT THE FIRE RATING OF THE FLOOR SHALL BE MAINTAINED.
SINGLE POLE SWITCH; SUBSCRIPT '3' INDICATES THREE-WAY SWITCH; SUBSCRIPT 'D'
INDICATES DIMMER SWITCH; SUBSCRIPT 'M' INDICATES MOTOR-RATED SWITCH; SUBSCRIPT 'R' INDICATES
RELOCATED; LOWERCASE SUBSCRIPT INDICATES LIGHTING CONTROL ZONE. SWITCH SHALL BE MOUNTED
AT 3'-8" AFF TO CENTER OF SWITCH, UON.
TELEPHONE/DATA OUTLET MOUNTING HEIGHT 18" AFF UNLESS OTHERWISE NOTED. PROVIDE RING AND
STRING ONLY.
TELEPHONE OUTLET MOUNTED 18" AFF; SUBSCRIPT "W" INDICATES WALL OUTLET
MOUNTED AT 48" AFF. PROVIDE RING AND STRING ONLY.
NFSS - SAFETY SWITCH - NON-FUSED TYPE; AMPS, POLES, NEMA ENCLOSURE AS SHOWN.
HOMERUN TO PANEL. CONDUCTORS SHALL BE (2) #12 AWG, + #12 GND., IN 3/4"
CONDUIT UNLESS OTHERWISE INDICATED.
HOMERUN TO PANEL. CONDUCTORS SHOWN ARE AS FOLLOWS: LONG HASH MARK WITH DOT INDICATES
GROUND CONDUCTOR; LONG HASH MARK INDICATES NEUTRAL CONDUCTOR; SHORT HASH MARKS
INDICATE PHASE CONDUCTORS. ALL CONDUCTOR
SHALL #12 AWG IN 3/4" CONDUIT, UNLESS OTHERWISE INDICATED.
LIGHTING:
1. FURNISH AND INSTALL A COMPLETE LIGHTING FIXTURE FOR EACH LIGHTING FIXTURE SYMBOL SHOWN ON
THE DRAWINGS.
2. ALL FIXTURES SHALL BE IN ACCORDANCE WITH ALL LOCAL MUNICIPAL AND STATE REQUIREMENTS
GOVERNING SAME AND SHALL BE U.L. APPROVED.
3. SUPPORTS FOR ALL FIXTURES SEPARATELY FROM THE SUSPENDED CEILING SYSTEM. PROVIDE A
MINIMUM OF TWO (2) GALVANIZED STEEL #12 GAUGE HANGER WIRES (ALTERNATE CORNERS) ON ALL
RECESSED FIXTURES.
4. FIXTURES IN AREAS W/O CEILING SHALL BE RIGIDLY SUPPORTED USING THREADED ROD, U-CHANNELS
OR SIMILAR MATERIALS.
5. ALL EXIT AND EMERGENCY LIGHTING CIRCUITS SHALL BE POWERED FROM EMERGENCY LIGHTING
BRANCH CIRCUITS FED FROM THE BUILDING'S EMERGENCY GENERATOR. MOUNT EXIT SIGNS AND
EMERGENCY LIGHITNG UNITS 96" ABOVE FINISHED FLOOR, AND USE GENERAL LIGHTING CIRCUITS
SERVING THE OCCUPIED AREAS.
6. MEANS OF EGRESS SHALL BE ILLUMINATED SO FAILURE OF A SINGLE ELEMENT OR BULB DOES NOT
LEAVE AN AREA IN TOTAL DARKNESS.
7. ALL FLUORESCENT LIGHTING FIXTURES AND FIXTURES SERVED FROM MULTI-WIRE BRANCH CIRCUITS
SHALL COMPLY WITH DISCONNECTING MEANS REQUIREMENTS SET FORTH IN NEC 410-120(G).
8. WALL MOUNTED OCCUPANCY SENSOR:
A. WALL MOUNTED OCCUPANCY SENSOR SHALL BE PASSIVE INFRARED AND SHALL HAVE 180 DEGREE
COVERAGE FOR A MINIMUM OF 900 SQUARE FEET. OCCUPANCY SENSOR SHALL HAVE AN
ADJUSTABLE TIME DELAY FROM 30 SECONDS TO 30 MINUTES AND SHALL FIT IN A STANDARD
OUTLET BOX. SENSOR SHALL BE MANUFACTURED BY WATTSTOPPER, SENSOR SWITCH, OR
APPROVED EQUAL.
9. CEILING MOUNTED OCCUPANCY SENSORS:
A. OPEN OFFICE/LARGE AREA APPLICATION: LOW VOLTAGE PASSIVE INFRARED OCCUPANCY SENSOR
RATED FOR OPEN OFFICE OR LARGE AREA APPLICATIONS. SENSOR SHALL BE IMMUNE TO RFI AND
EMI, SHALL HAVE AN EXTENDED RANGE FRESNEL LENS WITH 360 DEGREE COVERAGE FOR A
MINIMUM OF 1000 SQUARE OF OCCUPANCY DETECTION.
B. TOILET ROOM: LOW VOLTAGE OR LINE VOLTAGE ULTRASONIC OR DUAL TECHNOLOGY OCCUPANCY
SENSOR RATED FOR TOILET ROOM APPLICATIONS. SENSOR SHALL BE IMMUNE TO RFI AND EMI,
SHALL HAVE 360 DEGREE COVERAGE FOR A MINIMUM OF 500 SQUARE FEET. SENSOR SHALL HAVE
ADJUSTABLE TIME DELAY AND SENSITIVITY AND SHALL HAVE AN LED INDICATOR OF OCCUPANCY
DETECTION.
C. CONFERENCE/CLASSROOM AREAS: LOW VOLTAGE DUAL TECHNOLOGY SENSOR RATED FOR USE IN
CLASSROOM AND CONFERENCE ROOM APPLICATIONS. SENSOR SHALL HAVE COVERAGE FOR
WALKING MOTION UP TO 2000 SQUARE FEET AND COVERAGE FOR TYPICAL DESKTOP ACTIVITY UP
TO 1000 SQUARE FEET. SENSOR SHALL BE IMMUNE TO RFI AND EMI. SENSOR SHALL HAVE AN
ADJUSTABLE TIME DELAY AND SENSITIVITY AND SHALL HAVE AN LED INDICATOR OF OCCUPANCY
DETECTION. SENSOR SHALL BE WATTSTOPPER MODEL DT-200 SERIES OR APPROVED EQUAL.
OCCUPANCY SENSOR SHALL OPERATE WITH A COMPATIBLE POWER PACK.
D. HI-BAY/WAREHOUSE AREAS: LINE VOLTAGE, PASSIVE-INFRARED OCCUPANCY SENSOR WITH
360-DEGREE COVERAGE FOR USE IN HI-BAY WAREHOUSE APPLICATION. OCCUPANCY SENSOR
SHALL OPERATE AT 120V OR 277V AND SHALL MOUNT ON LIGHTING FIXTURE, JUNCTION BOX OR
OTHER ENCLOSURE. AFTER A USER SPECIFIED LENGTH OF TIME WHEN NO OCCUPANCY IS
DETECTED, LIGHTING SHALL AUTOMATICALLY SWITCH OFF. SENSOR SHALL BE WATTSTOPPER
SERIES HB OR APPROVED EQUAL.OCCUPANCY SENSORS SHALL BE MANUFACTURED BY WATT
STOPPER, SENSOR SWITCH OR APPROVED EQUAL.
E. OCCUPANCY SENSORS SHALL BE MANUFACTURED BY WATT STOPPER, LEVITON OR APPROVED
EQUAL.
10. COMMISSIONING
A. CONTRACTOR SHALL VERIFY ALL CONTROLS COMPLY WITH IECC SECTION C408.3.
B. CERTIFICATION DOCUMENTS SHALL BE PROVIDED TO THE OWNER WITHIN 90 DAYS OF CERTIFICATE
OF OCCUPANCY.
COMMUNICATION, DATA AND CONTROL SYSTEMS:
1. PLENUM CABLE; WHEN CONTROL AND SIGNAL WIRING IS INSTALLED W/0 METAL RACEWAY IN PLENUMS IT
SHALL COMPLY WITH 300.22, 2014 NEC.
2. TELEPHONE/DATA SYSTEM:
A. PROVIDE A WALL RING AND PULL STRING FOR EACH TELEPHONE OR DATA OUTLET WITH A 1/8"
NYLON PULL WIRE TO THE NEAREST ACCESSIBLE CEILING.
B. MOUNT TELEPHONE/DATA OUTLETS 18" ABOVE FINISHED FLOOR (UNLESS OTHERWISE NOTED).
3. FIRE ALARM SYSTEM NOTES:
A. THE ELECTRICAL DRAWINGS SHOW DIAGRAMMATIC LOCATIONS OF FIRE ALARM SYSTEM DEVICES
ONLY. ADDITIONAL DEVICES NOT SHOWN ON THE DRAWING MAY BE REQUIRED. THE FIRE ALARM
CONTRACTOR SHALL BE RESPONSIBLE FOR DESIGN OF A FULL SYSTEM AND SHALL PROVIDE ALL
DEVICES AND COMPONENTS AS REQUIRED FOR A COMPLETE WORKING SYSTEM THAT MEETS THE
REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. ARIUM'S DRAWINGS SHALL NOT BE
ALTERED BY THE CONTRACTOR FOR THE PURPOSE OF OBTAINING FIRE ALARM SYSTEM PERMITS.
THE GENERAL CONTRACTOR AND THEIR FIRE ALARM CONTRACTOR SHALL BE RESPONSIBLE FOR
OBTAINING THE FIRE ALARM PERMIT INCLUDING PREPARATION OF ALL REQUIRED STAMPED AND
UN-STAMPED DOCUMENTATION AND DRAWINGS BY THE AUTHORITY HAVING JURISDICTION.
B. REFER TO EXISTING FIRE ALARM SYSTEM DOCUMENTATION AND, IF APPLICABLE, SEPARATE FIRE
ALARM SYSTEM SPECIFICATIONS FOR MODIFICATIONS TO THE EXISTING BUILDING FIRE ALARM
SYSTEM.
C. ALL FIRE ALARM DEVICES, EQUIPMENT, AND INSTALLATION METHODS SHALL COMPLY WITH THE
NATIONAL ELECTRICAL CODE, ARTICLE 760; NFPA 72, NATIONAL FIRE ALARM CODE; NFPA 101, LIFE
SAFETY CODE; AMERICANS WITH DISABILITIES ACT; APPLICABLE BUILDING CODES; WITH LOCAL
AND MUNICIPAL CODES AND WITH THE AUTHORITY HAVING JURISDICTION. THE FIRE ALARM
SYSTEM AND ASSOCIATED COMPONENTS SHALL BE UL LISTED AND LABELED.
D. ALL NEW AND RELOCATED FIRE ALARM DEVICES SHALL BE CONNECTED TO THE EXISTING FIRE
ALARM SIGNALING AND NOTIFICATION CIRCUITS IN THE RENOVATED AREA. ALL NEW FIRE ALARM
DEVICES SHALL BE FULLY COMPATIBLE WITH THE EXISTING SYSTEM.
E. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING EXPANDER PANELS AS REQUIRED AND FOR
PROGRAMMING OF THE EXISTING SYSTEM. IT SHALL BE THE RESPONSIBILITY OF THE OWNER
AND/OR CONTRACTOR TO DETERMINE IF THE EXISTING FIRE ALARM SYSTEM IS CAPABLE OF
HANDLING ADDITIONAL DEVICES AND ZONES.
F. FIRE ALARM SYSTEM DEVICES SHALL BE INSTALLED PER MANUFACTURER'S RECOMMENDED
PROCEDURES. VISUAL NOTIFICATION APPLIANCES SHALL BE MOUNTED SUCH THAT THE ENTIRE
LENS IS NOT LESS THAN 80" ABOVE FINISHED FLOOR OR 6" BELOW CEILING, WHICHEVER IS LOWER.
AUDIBLE NOTIFICATION DEVICES SHALL BE MOUNTED SUCH THAT THE TOP OF THE DEVICE IS NOT
LESS THAN 90" ABOVE FINISHED FLOOR AND BELOW THE FINISHED CEILING AT A HEIGHT NOT LESS
THAN 6".
G. FIRE ALARM SYSTEM WIRING SHALL BE FIRE RATED MC CABLE.
ELECTRICAL NOTES:
1. REFER TO ARCHITECTURAL AND MECHANICAL DRAWINGS FOR RELATED INFORMATION.
2. REFER TO MECHANICAL PLANS FOR EXACT LOCATIONS OF HVAC EQUIPMENT AND CONTROL WIRING
REQUIREMENTS.
3. THE CONTRACTOR SHALL COORDINATE CONNECTIONS AT HVAC AND OTHER EQUIPMENT SPECIFIED
UNDER DIVISION 15 WITH THE MECHANICAL CONTRACTOR PRIOR TO INSTALLATION.
4. COORDINATION SHALL INCLUDE THE CONTRACTOR'S DETERMINATION OF THE FOLLOWING INFORMATION:
METHOD OR TYPE OF TERMINATION FOR EACH CIRCUIT; THE VOLTAGE, AMPACITY AND NUMBER OF
WIRES REQUIRED FOR EACH CIRCUIT; DISCONNECT SWITCH AND/OR MOTOR STARTER REQUIRED AT
EACH TERMINATION POINT.
5. THE CONTRACTOR SHALL FULLY COORDINATE CONNECTIONS AT EQUIPMENT PROVIDED BY OTHERS AND
SHALL VERIFY ALL ELECTRICAL REQUIREMENTS PRIOR TO INSTALLATION.
5. CONTRACTOR SHALL VERIFY ALL RATINGS, SIZES, FINISHES, ETC. OF ALL EQUIPMENT AND SHALL VERIFY
ANY DISCREPANCIES IDENTIFIED IN DRAWINGS WITH ENGINEER PRIOR TO ORDERING AND INSTALLATION.
6. PLENUM WIRING SHALL COMPLY WITH NEC 300.22.
7. ELECTRICAL INSTALLATIONS SHALL BE PERFORMED IN ACCORDANCE WITH NFPA 70, THE NATIONAL
ELECTRICAL CODE, AND EXECUTIVE REGULATION 21-94, AND ALL LOCAL CODES AND AUTHORITIES
HAVING JURISDICTION. ALL ELECTRICAL EQUIPMENT SHALL BE CLEARLY LABELED, MARKED OR STAMPED
WITH THE SYMBOL OF AN ELECTRICAL TESTING LABORATORY APPROVED BY THE LOCAL FIRE MARSHAL
(REF MC-FSC).
8. SERVICE DISCONNECTS RATED OVER 1000 AMPS SHALL COMPLY WITH NEC 230.95.
9. CIRCUIT BREAKERS WHERE THE HIGHEST CONTINUOUS CURRENT TRIP SETTING IS RATED OR CAN BE
ADJUSTED TO 1200 AMPS OR HIGHER SHALL COMPLY WITH NEC 240.87.
10. VERIFY ALL OUTLET LOCATIONS ON JOB PRIOR TO ROUGH-IN.
11. COORDINATE ALL OUTLET BOX LOCATIONS WITH MASONRY TO MINIMIZE CUTTING AND PATCHING OF
BOTH BRICK AND BLOCK.
12. INDIVIDUAL HOME RUNS ARE SHOWN FOR CLARITY ONLY. ELECTRICAL CONTRACTOR MAY COMBINE
THEM TOGETHER PER THE NEC. ALL BRANCH CIRCUITS SHALL BE #12 AWG THNN OR THWN COPPER
CONDUCTORS UNLESS OTHERWISE NOTED AT THE HOME RUN OR INDICATED IN A SCHEDULE. MINIMUM
CONDUIT SIZE SHALL BE 3/4".
13. CONTRACTOR SHALL PROVIDE FIELD APPLIED HAZARD MARKINGS PER NEC 110.21(B)
14. CONTRACTOR SHALL COORDINATE WITH BUILDING OWNER ON REQUIREMENTS TO X-RAY SLAB PRIOR TO
ALL CORE DRILLING.
15. CONTRACTOR SHALL PROVIDE TAMPER PROOF RECEPTACLES AS REQUIRED PER NEC 406.12.
16. EMERGENCY LIGHTING FIXTURES AND EXIT SIGNS SHALL BE FED FROM EMERGENCY LIGHTING BRANCH
CIRCUITS FED FROM THE BUILDING'S EMERGENCY GENERATOR.
MOTOR CONNECTION
WALL MOUNTED OCCUPANCY SENSOR; SUBSCRIPT 'D' INDICATES DIMMER SWITCH; LOWERCASE
SUBSCRIPT INDICATES LIGHTING CONTROL ZONE.
2'x4' LIGHT FIXTURE; SUBSCRIPT 'R' INDICATES RELOCATE; SUBSCRIPT 'A' INDICATES FIXTURE TYPE;
SUBSCRIPT 'E' INDICATES EXISTING FIXTURE; LOWERCASE SUBSCRIPT INDICATES LIGHTING CONTROL
ZONE; 'NL' SUBSCRIPT INDICATES NIGHTLIGHT; SUBSCRIPT "EM" INDICATES EMERGENCY.
DOWNLIGHT; SUBSCRIPT 'R' INDICATES RELOCATE; SUBSCRIPT 'A' INDICATES FIXTURE TYPE; SUBSCRIPT 'E'
INDICATES EXISTING FIXTURE; LOWERCASE SUBSCRIPT INDICATES LIGHTING CONTROL ZONE; SUBSCRIPT
"EM" INDICATES EMERGENCY.
CEILING MOUNTED OCCUPANCY SENSOR; LOWERCASE SUBSCRIPT INDICATES LIGHTING CONTROL ZONE.
SPECIAL RECEPTACLE; MOUNTING HEIGHT 18" AFF UNLESS OTHERWISE NOTED. SUBSCRIPT INDICATES
NEMA RATING OF RECEPTACLE.
FLOOR MOUNTED TELECOM OUTLET. ROUTE 1" SCHEDULE 40 PVC CONDUIT FROM TELECOM OUTLET TO
CLOSEST WALL AND STUB UP TO ACCESSIBLE CEILING SPACE.
2'x2' LIGHT FIXTURE; SUBSCRIPT 'R' INDICATES RELOCATE; SUBSCRIPT 'A' INDICATES FIXTURE TYPE;
SUBSCRIPT 'E' INDICATES EXISTING FIXTURE; LOWERCASE SUBSCRIPT INDICATES LIGHTING CONTROL
ZONE; 'NL' SUBSCRIPT INDICATES NIGHTLIGHT; SUBSCRIPT "EM" INDICATES EMERGENCY.
WALL MOUNTED EXTERIOR FIXTURE; SUBSCRIPT 'A' INDICATES FIXTURE TYPE; SUBSCRIPT
'EM' INDICATES EMERGENCY FIXTURE.
TIME CLOCK
PHOTOCELL
SERVICE AND DISTRIBUTION:
1. PANELBOARDS:
A. PROVIDE DISTRIBUTION AND BRANCH CIRCUIT PANELBOARDS WITH FEATURES AND RATINGS
AS INDICATED ON THE DRAWINGS. THESE SHALL INCLUDE, BUT NOT BE LIMITED TO, THE
FOLLOWING: VOLTAGE, BUS RATING, FULLY-RATED SYMMETRICAL AMPERES INTERRUPTING
CAPACITY (AIC), PHASE, NUMBER OF WIRES, NUMBER OF POLES, MAIN CIRCUIT BREAKER OR
MAIN LUGS ONLY.
B. PANELBOARDS SHALL COMPLY WITH NEMA PB1 AND UL 67. PANELBOARDS SHALL HAVE FULLY
RATED COPPER MAIN BUS BAR, FIFTY PERCENT COPPER GROUND BUS BAR AND A FULL RATED
INSULATED NEUTRAL BUS BAR, WHERE INDICATED. PANELBOARDS SHALL HAVE COPPER LUGS.
C. CIRCUIT BREAKERS SHALL BE BOLT-ON FOR BOTH 480V AND 208V PANELBOARDS. CIRCUIT
BREAKERS SHALL BE OF THE THERMAL MAGNETIC TYPE WITH ACCESSORIES (SHUNT TRIP,
GROUND FAULT PROTECTION, ETC.) AS INDICATED ON THE PANELBOARD SCHEDULE. IN
INSTANCES WHERE "SPACE" IS INDICATED ON THE SCHEDULE, PROVIDE FULLY EQUIPPED
SPACE INCLUDING BUS FOR FUTURE INSTALLATION OF CIRCUIT BREAKERS.
D. PROVIDE A TYPED CIRCUIT DIRECTORY MOUNTED INSIDE FRONT DOOR OF PANEL ENCLOSURE.
E. PANELBOARD SHALL BE PERMANENTLY MARKED TO INDICATE WHERE THE POWER
ORIGINATES. THIS LABEL SHALL BE PERMANENTLY AFFIXED, OF SUFFICIENT DURABILITY TO
WITHSTAND THE ENVIRONMENT INVOLVED AND NOT HAND WRITTEN.
F. PANELBOARDS SHALL BE MANUFACTURED BY CUTLER HAMMER, GENERAL ELECTRIC, SQUARE
D OR SIEMENS.
G. THE CONTRACTOR SHALL BALANCE THE LOADING ON ALL PANELBOARDS AS CLOSELY AS
POSSIBLE AND TO THE SATISFACTION OF THE ENGINEER.
H. THE CIRCUIT NUMBERS USED ON THE DRAWINGS ARE FOR IDENTIFICATION ONLY AND THE
CIRCUIT NUMBER IN THE PANEL NEED NOT NECESSARILY CORRESPOND. EACH CIRCUIT IN THE
PANELS, HOWEVER, SHALL BE ACCURATELY INDEXED AS SPECIFIED HEREIN. CIRCUITS SHALL
BE ARRANGED IN PANELS SO THAT ALL LIGHTING CIRCUITS ARE TOGETHER, ALL MOTOR
CIRCUITS ARE TOGETHER, ETC.
2. SAFETY SWITCHES:
A. SAFETY SWITCHES SHALL BE PROVIDED WITH RATINGS AND ACCESSORIES AS INDICATED ON
THE CONTRACT DOCUMENTS. THESE INCLUDE, BUT ARE NOT LIMITED TO, THE FOLLOWING:
AMPERE RATING, VOLTAGE RATING, NO. OF POLES, FUSIBLE OR NON-FUSIBLE. SAFETY
SWITCHES SHALL BE MANUALLY OPERATED AND HAVE A QUICK-MAKE, QUICK-BREAK
SWITCHING MECHANISM. SAFETY SWITCHES SHALL HAVE MECHANICAL LUGS SUITABLE FOR
COPPER CONDUCTORS AND SHALL COMPLY WITH UL 98 AND NEMA KS-1.
B. FUSED SWITCHES RATED FOR 30A TO 600A SHALL BE EQUIPPED WITH CLASS R FUSE CLIPS
AND SHALL HAVE R FUSE REJECTION CAPABILITY. FUSED SWITCHES RATED FOR 800A TO
1200A SHALL BE EQUIPPED WITH CLASS L FUSE CLIPS. SWITCHES SHALL HAVE UL LISTED
SHORT CIRCUIT CURRENT RATING OF 200,000 RMS SYMMETRICAL AMPS.
C. ENCLOSURE SHALL BE NEMA 1 FOR INDOOR INSTALLATIONS AND NEMA 3R FOR EXTERIOR
INSTALLATIONS. ENCLOSURE SHALL HAVE ON/OFF MARKINGS AND SHALL HAVE A BLACK OR
RED OPERATING HANDLE. HANDLE SHALL BE CAPABLE OF BEING PAD-LOCKABLE IN THE 'OFF'
POSITION. ENCLOSURE DOOR SHALL HAVE DEFEATABLE INTERLOCKS TO PREVENT OPENING
OF THE SWITCH COVER WHEN THE SWITCH IS 'ON' AND TO PREVENT TURNING THE SWITCH 'ON'
WHEN THE COVER IS OPEN.
D. SAFETY SWITCHES SHALL BE MANUFACTURED BY CUTLER HAMMER, GENERAL ELECTRIC,
SIEMENS OR SQUARE D.
E. PROVIDE SAFETY SWITCH WITH PROVISIONS SUCH THAT THE SWITCH SHALL BE LOCKABLE IN
THE "ON" POSITION.
3. DRY TYPE TRANSFORMERS:
A. DRY TYPE TRANSFORMERS SHALL BE PROVIDED WITH KVA RATINGS, PRIMARY VOLTAGE AND
SECONDARY VOLTAGE AS INDICATED ON THE DRAWINGS. DRY TYPE TRANSFORMERS SHALL
COMPLY WITH UL ST 20 AND UL 1561.
B. TRANSFORMER ENCLOSURES SHALL BE RATED FOR INDOOR USE AND OF THE VENTILATED
TYPE. TRANSFORMERS SHALL HAVE AN INSULATION CLASS OF 220 DEGREES CELSIUS CLASS
WITH 150 DEGREE CELSIUS TEMPERATURE RISE.
C. PROVIDE SIX FULL CAPACITY 2.5 PERCENT TAPS, TWO ABOVE AND FOUR BELOW NOMINAL
VOLTAGE.
D. TRANSFORMERS SHALL BE MANUFACTURED BY CUTLER HAMMER, GENERAL ELECTRIC,
SIEMENS OR SQUARE D.
4. FUSES:
A. FUSES RATED FOR 600 AMPERES AND LESS FOR FEEDER, BRANCH AND MOTOR CIRCUITS
SHALL BE DUAL ELEMENT UL CLASS RK-5 CURRENT-LIMITING TIME DELAY TYPE. FUSES SHALL
HAVE A TIME DELAY OF 10 SECONDS MINIMUM AT 500 PERCENT OF AMPERE RATING OF FUSE.
FUSE SHALL HAVE INTERRUPTING RATING OF 200,000 RMS SYMMETRICAL AMPS. FUSES SHALL
BE DUAL-ELEMENT CONSTRUCTION INCORPORATING A THERMAL OVERLOAD ELEMENT USING
250 DEGREES FAHRENHEIT MELTING POINT ALLOY FOR THERMAL PROTECTION AND A
SEPARATE SHORT CIRCUIT ELEMENT.
B. FUSES RATED FOR 601 AMPERES AND GREATER FOR FEEDER CIRCUITS AND SERVICE
ENTRANCE EQUIPMENT SHALL BE DUAL ELEMENT UL CLASS L CURRENT-LIMITING TIME DELAY
TYPE. FUSES SHALL HAVE A TIME DELAY OF FOUR SECONDS MINIMUM AT 500 PERCENT OF
AMPERE RATING OF FUSE. FUSE SHALL HAVE INTERRUPTING RATING OF 200,000 RMS
SYMMETRICAL AMPERES. FUSES SHALL BE DUAL-ELEMENT CONSTRUCTION INCORPORATING A
THERMAL OVERLOAD ELEMENT USING 250 DEGREES FAHRENHEIT MELTING POINT ALLOY FOR
THERMAL PROTECTION AND A SEPARATE SHORT CIRCUIT ELEMENT.
C. FUSES SHALL BE MANUFACTURED BY BUSSMAN, FERRAZ SHAWMUT OR APPROVED EQUAL.
5. ENCLOSED CIRCUIT BREAKER:
A. ENCLOSED CIRCUIT BREAKERS SHALL COMPLY WITH NEMA AB 1 1993 AND UL 489. CIRCUIT
BREAKERS SHALL BE MOLDED CASE CIRCUIT BREAKERS WITH INVERSE TIME AND
INSTANTANEOUS TRIPPING CHARACTERISTICS. CIRCUIT BREAKER SHALL BE OPERATED BY A
TOGGLE-TYPE HANDLE WHICH SHALL PROVIDE QUICK-MAKE, QUICK-BREAK CONTACT ACTION.
THE CIRCUIT BREAKER SHALL HAVE COMMON TRIPPING OF ALL POLES.
B. CIRCUIT BREAKER SHALL BE PROVIDED WITH A PUSH-TO-TRIP BUTTON ON THE FACE OF THE
CIRCUIT BREAKER TO MECHANICALLY OPERATE THE CIRCUIT BREAKER TRIPPING MECHANISM
FOR MAINTENANCE. CIRCUIT BREAKERS SHALL HAVE A MINIMUM SYMMETRICAL INTERRUPTING
CAPACITY AS INDICATED ON THE DRAWINGS.
C. ENCLOSED CIRCUIT BREAKERS SHALL BE PROVIDED WITH A SURFACE MOUNTED NEMA 1
GENERAL PURPOSE ENCLOSURE INTENDED FOR INDOOR USE, UNLESS OTHERWISE NOTED.
ENCLOSURE SHALL COMPLY WITH UL 50 AND NEMA 250. ENCLOSURE SHALL HAVE PROVISIONS
FOR PADLOCKING THE CIRCUIT BREAKER IN THE "OFF" POSITION. ENCLOSURE SHALL HAVE A
GRAY BAKED ENAMEL PAINT FINISH.
D. ENCLOSED CIRCUIT BREAKER SHALL BE MANUFACTURED BY CUTLER HAMMER, GENERAL
ELECTRIC, SIEMENS OR SQUARE D.
6. POWER POLE:
A. THE ASSEMBLY SHALL CONSIST OF MODULAR VERTICAL CHANNELS WITH SEPARATE CHASES
FOR LINE VOLTAGE AND LOW VOLTAGE WIRING. THE SYSTEM SHALL CONSIST OF A
PRE-PUNCHED SUPPORT, ALUMINUM END COVERS AND A METALLIC CENTER PANEL. THE
MULTI-OUTLET ASSEMBLY SHALL COMPLY WITH NEC 380 AND SHALL BE UL LISTED.
B. THE SYSTEM SHALL BE AVAILABLE WITH AN EXTENSION KIT THAT ALLOWS FOR VARYING
CEILING HEIGHTS. THE FRAME SUPPORTS SHALL BE AVAILABLE WITH FACTORY PRE-PUNCHED
HOLES FOR COMMUNICATION OUTLETS AND TRADE KNOCKOUTS FOR ELECTRICAL
TERMINATIONS. A PLATE WITH OPENINGS AND KNOCKOUTS SHALL BE PROVIDED TO FEED
MODULAR SYSTEMS FURNITURE.
C. THE POWER POLE SHALL BE MECHANICALLY AND ELECTRICALLY CONTINUOUS AND SHALL BE
BONDED IN ACCORDANCE WITH THE NEC. THE SYSTEM SHALL BE SECURELY SUPPORTED AT
THE CEILING AND THE FLOOR IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION
REQUIREMENTS. POWER POLE SHALL BE MANUFACTURED BY WIREMOLD OR APPROVED
EQUAL.
7. FLOOR BOXES:
A. FLOOR BOX SHALL PROVIDE INTERFACE BETWEEN POWER AND COMMUNICATION CABLING IN
AN ON GRADE OR ABOVE GRADE CONCRETE FLOOR. FLOOR BOX SHALL COMPLY WITH UL
514A, NEC 300-21 AND SHALL MEET APPLICABLE SAFETY STANDARDS FOR SCRUB-WATER
EXCLUSION.
B. FLOOR BOX SHALL BE MADE OF STAMPED STEEL AND SHALL HAVE TWO INDEPENDENT WIRING
COMPARTMENTS THAT CAN ACCOMMODATE UP TO TWO DUPLEX RECEPTACLES OR
COMMUNICATION DEVICES. FLOOR BOX SHALL PERMIT TUNNELING FROM END POWER
COMPARTMENT TO END POWER COMPARTMENT. EACH COMPARTMENT SHALL HAVE MINIMUM
WIRING CAPACITY OF 50 CUBIC INCHES. FLOOR BOX ACTIVATION COVERS SHALL BE MADE OF
DIE-CAST ALUMINUM OR DIE-CAST ZINC AND SHALL HAVE A METAL OR POWDER-COATED
FINISH. ACTIVATION COVER TYPES SHALL BE COORDINATED WITH TYPE OF FLOORING IN
WHICH THEY WILL BE INSTALLED AND SHALL BE AVAILABLE IN FLANGED OR FLANGELESS
VERSIONS.
C. FLOOR BOX SHALL BE LEGRAND EVOLUTION FLOOR BOX OR APPROVED EQUAL.
EMERGENCY LIGHTING UNIT.
EXIT LIGHT FIXTURE. PROVIDE DIRECTIONAL ARROWS AS SHOWN. SUBSCRIPT 'R' INDICATES RELOCATE;
SUBSCRIPT "E" INDICATES EXISTING.
DUPLEX RECEPTACLE, NEMA 5-20R. MOUNTING HEIGHT +18" AFF UNLESS OTHERWISE NOTED. SUBSCRIPT
'G' INDICATES GROUND FAULT CIRCUIT INTERRUPTER TYPE; SUBSCRIPT 'WP' INDICATES WEATHERPROOF
ENCLOSURE; SUBSCRIPT USB INDICATES INTEGRAL USB PORT.
QUAD RECEPTACLE, NEMA 5-20R. MOUNTING HEIGHT +18" AFF UNLESS OTHERWISE NOTED.
JUNCTION BOX
FLOOR MOUNTED JUNCTION BOX
CONDUIT UP
480Y/277 V SURFACE MOUNTED PANELBOARD
208Y/120 V SURFACE MOUNTED PANELBOARD
TRANSFORMER
ENCLOSED CIRCUIT BREAKER
CONDUIT ROUTED THROUGH OR UNDER FLOOR SLAB
FLOOR MOUNTED RECEPTACLE. ROUTE 1" SCHEDULE 40 PVC CONDUIT THRU FLOOR SLAB FROM
RECEPTACLE TO CLOSEST WALL.
1'x4' LIGHT FIXTURE; SUBSCRIPT 'R' INDICATES RELOCATE; SUBSCRIPT 'A' INDICATES FIXTURE TYPE;
SUBSCRIPT 'E' INDICATES EXISTING FIXTURE; LOWERCASE SUBSCRIPT INDICATES LIGHTING CONTROL
ZONE; 'EM' SUBSCRIPT INDICATES EMERGENCY FIXTURE.
AUDIBLE DEVICE - SPEAKER.
VISUAL DEVICE. NUMBER INDICATES CANDELA RATING. SUBSCRIPT 'E' INDICATES EXISTING DEVICE;
SUBSCRIPT 'R' INDICATES RELOCATED DEVICE.
COMBINATION AUDIBLE/VISUAL DEVICE. NUMBER INDICATES CANDELA RATING.
DUCT SMOKE DETECTOR.
PHOTOELECTRIC SMOKE DETECTOR.
MANUAL PULL STATION; SUBSCRIPT 'E' INDICATES EXISTING. MOUNT AT 48" AFF.
FIRE ALARM CONTROL PANEL
FIRE ALARM ANNUNCIATOR PANEL
A
A
OS
MS
A
6-30R
J
J
T
M
V 15
A
AV 15
S P
S D
F E
FAA
FCP
TC
PC
A
EM
A
A
DATA OUTLET MOUNTING HEIGHT 18" AFF UNLESS OTHERWISE NOTED. PROVIDE RING AND STRING ONLY.
J P
POWER CONNECTION FOR SYSTEMS FURNITURE. COORDINATE FINAL CONNECTIONS WITH SUPPLIER AND
TENANTS REPRESENTATIVE IN THE FIELD.
J T/D
TELE/DATA CONNECTION AT SYSTEMS FURNITURE. COORDINATE FINAL CONNECTIONS WITH SUPPLIER AND
TENANTS REPRESENTATIVE IN THE FIELD.
PP
POWER POLE.
SYMBOLS LIST
NOTE: SYMBOLS ARE FOR REFERENCE ONLY. NOT ALL ARE USED IN THIS PROJECT.
ABBREVIATIONS LIST
NOTE: ABBREVIATIONS ARE FOR REFERENCE ONLY. NOT ALL ARE
USED IN THIS PROJECT.
DRAWING INDEX
E1
COVER SHEET - ELECTRICAL
E2
FLOOR PLANS - NEW WORK - ELECTRICAL
E3
ELECTRICAL RISER DIAGRAM AND SCHEDULES
E4
ELECTRICAL SCHEDULES
SYMBOLS AND ABBREVIATIONS:
A, AMP AMPERE
AC
ALTERNATING CURRENT
AFF
ABOVE FINISHED FLOOR
AHU
AIR HANDLING UNIT
AIC
AMPERES INTERRUPTING CAPACITY
ATS
AUTOMATIC TRANSFER SWITCH
AWG
AMERICAN WIRE GAUGE
BLDG
BUILDING
C, COND CONDUIT
CB
CIRCUIT BREAKER
CKT
CIRCUIT
CLG
CEILING
CU
CONDENSING UNIT
DEGS
DIESEL ENGINE GENERATOR SET
DISC
DISCONNECT
DWG
DRAWING
E
EXISTING
ECB
ENCLOSED CIRCUIT BREAKER
EF
EXHAUST FAN
ELEC
ELECTRICAL
EM
EMERGENCY
EMT
ELECTRICAL METAL TUBING
EPO
EMERGENCY POWER OFF
EQUIP
EQUIPMENT
ESS
ELEVATOR SELECTOR SWITCH
EWC
ELECTRIC WATER COOLER
EWH
ELECTRIC WATER HEATER
EX
EXISTING
FAA
FIRE ALARM ANNUNCIATOR PANEL
FACP
FIRE ALARM CONTROL PANEL
FLA
FULL LOAD AMPS
FSS
FUSED SAFETY SWITCH
G
GROUND
GFCI
GROUND FAULT CURRENT INTERRUPTER
HP
HORSEPOWER
IG
ISOLATED GROUND
J, JB, JBOX JUNCTION BOX
KVA
KILOVOLT AMPERE
KW
KILLOWATT
LED
LIGHT EMITTING DIODE
LTG
LIGHTING
MCB
MAIN CIRCUIT BREAKER
MECH
MECHANICAL
MLO
MAIN LUGS ONLY
MOCP
MAXIMUM OVERCURRENT PROTECTION
N/A
NOT APPLICABLE
N
NEUTRAL
NEC
NATIONAL ELECTRICAL CODE
NEMA
NATIONAL ELECTRICAL MANUFACTURERS
ASSOCIATION
NFPA
NATIONAL FIRE PROTECTION ASSOCIATION
NFSS
NON-FUSED SAFETY SWITCH
NIC
NOT IN CONTRACTOR
NL
NIGHT LIGHT
NTS
NOT TO SCALE
PH, Ɵ
PHASE
P
POLE
PNL
PANELBOARD
QTY
QUANTITY
REL
RELOCATED
RELOC
RELOCATED
REQ'D
REQUIRED
RM
ROOM
RTU
ROOF TOP UNIT
RX
REMOVE
SCHED
SCHEDULE
SWBD
SWITCHBOARD
T, XFMR TRANSFORMER
TBD
TO BE DETERMINED
TYP
TYPICAL
UNV
UNIVERSAL VOLTAGE
UON
UNLESS OTHERWISE NOTED
V
VOLT OR VOLTAGE
VA
VOLT AMPERE
VAV
VARIABLE AIR VOLUME
W
WATT
WH
WALL HEATER
WP
WEATHERPROOF ENCLOSURE
# NUMBER
STAMP
SWITCHED QUAD RECEPTACLE, NEMA 5-20R. MOUNTING HEIGHT +18" AFF UNLESS OTHERWISE NOTED.
SWITCHED DUPLEX RECEPTACLE, NEMA 5-20R. MOUNTING HEIGHT +18" AFF UNLESS OTHERWISE NOTED.
CLOSED LOOP SINGLE ZONE PHOTOSENSOR; LOWERCASE SUBSCRIPT INDICATES LIGHTING CONTROL
ZONE.
PS
EXISTING TO REMAIN ITEM
DEMOLISH OR RELOCATE ITEM
NEW ITEM
ISSUED FOR 100% REVIEW - DATE: 04-05-2024 - NOT FOR CONSTRUCTION
MAR 2023
ARCHITECT / MEP ENGINEER: DESCRIPTION
DATE
REV. NO.
c
TITLE
PROJECT FILE NAME: LATEST REVISION: ISSUE DATE:
DWG NO.
BY:
COPYRIGHT Arium AE, LLC
SM: PM:
SP95-3CCR
2024
CONTRACTOR:
PROJECT MANAGER:
JBG SMITH
6596 SPRINGFIELD CENTER DRIVE
SPRINGFIELD .VA 22150
571-444-0323
PROJECT:
33215 ROOM CONVERSION
3RD FLOOR
6595 SPRINGFIELD CENTER DRIVE
SPRINGFIELD, VA 22150
MORGAN STATE UNIVERSITY SA+P | 45
44 |
c
R
D
R
D
MAR 2023
NORMAL POWER
LINE
EX
EX
PLAN
NORTH
NORMAL
LIGHTING
NORMAL POWER
NEUTRAL
0
1'
KP
2' 4'
SCALE 1/4" = 1' - 0"
EX
V R
75
CRITICAL DIMENSIONS SHALL NOT BE SCALED
EXISTING CONDITIONS HAVE BEEN PARTIALLY
FIELD VERIFIED BY ARIUM AE.
ON/OFF
CONTROL
DEVICE
EMERGENCY
LIGHTING
CONTROL
UNIT
EXTENT OF WORK
1
14-30R
60
2
DEMOLITION FLOOR PLAN
ELECTRICAL
EMERGENCY LIGHTING CONTROL UNIT:
A. EMERGENCY LIGHTING CONTROL UNIT (ELCU) SHALL CONTROL LIGHTING IN AREAS WHERE
EMERGENCY LIGHTING FIXTURES ARE CONNECTED TO DEDICATED EMERGENCY LIGHTING
CIRCUITS AND SHALL ALLOW NORMAL CONTROL OF EMERGENCY LIGHTING.
B. ELCU SHALL COMPLY WITH UL 924 AND SHALL BE UL LISTED AS EMERGENCY LIGHTING AND
POWER EQUIPMENT. ELCU SHALL HAVE AN INTEGRAL PUSH-TO-TEST BUTTON AND SHALL BE
RATED FOR BALLAST LOADS (10A AT 120V), INCANDESCENT LOADS (2A AT 120V) AND MOTOR
LOADS (1HP AT 120V).
C. ELCU SHALL BE MANUFACTURED BY WATTSTOPPER, ENTERTAINMENT NETWORKS, LIGHTING
CONTROL & DESIGN OR APPROVED EQUAL.
ELCU WIRING SCHEMATIC
46 |
NOT TO SCALE
8'
EMERGENCY
LIGHTING
EMERGENCY POWER
LINE
EMERGENCY POWER
NEUTRAL
SECURITY SYSTEM NOTES:
CR
1. CONTRACTOR SHALL CONFIRM EQUIPMENT REQUIRED AT EACH DOOR AND
SELECT THE APPROPIATE ROUGH-IN FOR EACH DEVICE FROM THE ROUGH-IN
REQUIREMENTS DRAWING PROVIDED BY TENANT.
2. PROVIDE AND INSTALL BACK BOXES, CONDUIT W/END BUSHINGS FOR ALL
DEVICES SHOWN IN ACCORDANCE WITH THE TYPICAL ROUGH-IN DRAWINGS.
CARD READER; PROVIDE GANG BOX AT 42" AFF TO CENTER AND 12" MAX.
FROM EDGE OF DOOR FRAME. STUB-UP 3/4" CONDUIT TO ABOVE CEILING WITH
PULL-STRING. ALL CARD READERS SHALL COMPLY WITH IBC CODE
REQUIREMENTS AND SHALL ALLOW FREE EGRESS IN THE DIRECTION OF
EGRESS.
EX
EX
PLAN
NORTH
0
1'
4
EM
EM
CIRCULATION
3K41W
2' 4'
SCALE 1/4" = 1' - 0"
EX
CRITICAL DIMENSIONS SHALL NOT BE SCALED
EXISTING CONDITIONS HAVE BEEN PARTIALLY
FIELD VERIFIED BY ARIUM AE.
GENERAL NOTES:
EXTENT OF WORK
3
6
OS
5
A1
EM
CONFERENCE ROOM
3J37W
8'
3K41W CIRCULATION
1. REFER TO DRAWING E1 FOR SYMBOLS, ABBREVIATIONS AND SPECIFICATIONS.
OFFICE
3H36W
COPY
3J36W
LIGHTING FLOOR PLAN
NEW WORK - ELECTRICAL
2. REFER TO DRAWING E3 FOR ELECTRICAL RISER DIAGRAM AND DRAWING E4 FOR ELECTRICAL SCHEDULES.
3. ALL BRANCH CIRCUITS TO BE DEMOLISHED SHALL BE REMOVED BACK TO THE RESPECTIVE PANEL AND
LABELED AS 'SPARE.' CONTRACTOR SHALL VERIFY SPARE CIRCUITS AVAILABLE AT EXISTING PANELS DURING
THE COURSE OF DEMOLITION AND SHALL VERIFY THAT ENOUGH SPARE CIRCUITS ARE IDENTIFIED TO
ACCOMMODATE THE BRANCH CIRCUITS SHOWN ON THE NEW WORK DRAWINGS.
4. IN THE EVENT THAT ENOUGH SPARE CIRCUITS ARE NOT IDENTIFIED TO ACCOMMODATE THOSE CALLED OUT ON
THE NEW WORK PLANS, THE CONTRACTOR SHALL IMMEDIATELY BRING THIS TO THE ATTENTION OF THE
CLIENT'S REPRESENTATIVE.
5. FIRE ALARM SYSTEM SHALL REMAIN OPERATIONAL DURING THE COURSE OF DEMOLITION. CONTRACTOR
SHALL COORDINATE ANY OUTAGES WITH THE PROPERTY MANAGER'S REPRESENTATIVE.
6. REFER TO LIGHTING SPECIFICATIONS ON DRAWING E1 FOR DEFINITION OF OCCUPANCY SENSORS TO BE
UTILIZED IN DIFFERENT ROOM APPLICATIONS.
7. EMERGENCY LIGHTING FIXTURES AND EXIT SIGNS SHALL BE FED FROM EMERGENCY LIGHTING BRANCH
CIRCUITS FED FROM THE BUILDING'S EMERGENCY GENERATOR.
8. ALL WALL MOUNTED OCCUPANCY SENSORS ON EXTERIOR WALLS WITH WINDOWS SHALL BE PROVIDED WITH
DIMMER SWITCH.
9. LIGHTING IN AREAS WITH OCCUPANCY SENSORS SHALL BE MANUAL "ON" BY LOCAL SWITCH AND THE
OCCUPANCY SENSOR SHALL ACT TO TURN LIGHTING FIXTURES "OFF" WITHIN TWENTY MINUTES OF ALL
OCCUPANTS LEAVING THE SPACE.
10. IN AREAS WHERE THERE ARE MULTIPLE LIGHTING SWITCHES IN ONE LOCATION, LOCATE ALL SWITCHES UNDER
ONE FACEPLATE AND ENGRAVE FACEPLATE WITH DESIGNATED LIGHTING ZONES.
1
2
3
4
5
6
7
8
9
10
11
EX
EX
PLAN
NORTH
0
CR
CIRCULATION
3K41W
EX
V R
75
EXTENT OF WORK
CONFERENCE ROOM
3J37W
11
HM3WB-25,27,29 9
J
1'
2' 4'
SCALE 1/4" = 1' - 0"
CRITICAL DIMENSIONS SHALL NOT BE SCALED
EXISTING CONDITIONS HAVE BEEN PARTIALLY
FIELD VERIFIED BY ARIUM AE.
60
10
3K41W CIRCULATION
DISCONNECT EX. RECEPTACLES AND RETAIN BRANCH CIRCUIT FOR CONNECTION TO NEW
RECEPTACLES IN THIS ROOM. REFER TO POWER FLOOR PLAN.
DISCONNECT EX. WASHER/DRYER RECEPTACLE AND RETAIN FOR RELOCATION AT SAME LOCATION.
CONNECT TO EXISTING 277V NORMAL LIGHTING BRANCH CIRCUIT SERVING THIS AREA. THERE SHALL
BE A MAXIMUM OF 16A ON A 20A, 277V NORMAL LIGHTING BRANCH CIRCUIT.
CONNECT TO EXISTING 277V EMERGENCY LIGHTING BRANCH CIRCUIT SERVING THIS AREA. THERE
SHALL BE A MAXIMUM OF 16A ON A 20A, 277V EMERGENCY LIGHTING BRANCH CIRCUIT.
MODIFY LIGHTING IN THIS AREA AS SHOWN.
PROVIDE EMERGENCY LIGHTING CONTROL UNIT (ELCU) LOCATED ABOVE ACCESSIBLE CEILING SPACE
TO ALLOW FOR CONTROL OF EMERGENCY LIGHTING FIXTURE BY LOCAL SWITCHING MEANS. ELCU
SHALL CONNECT TO BOTH THE LOCAL NORMAL BRANCH CIRCUIT AND EMERGENCY BRANCH CIRCUIT.
REFER TO DETAIL ON THIS DRAWING.
EXTEND RETAINED RECEPTACLE BRANCH CIRCUIT TO NEW LOCATION.
CONNECT TO EX. RECEPTACLE BRANCH CIRCUIT SERVING THIS AREA.
FAN-POWERED VAV BOX (FAN: 1/3 HP, 277V, 1PH; HEAT: 3.6KW, 480V, 3PH).
PROVIDE NFSS (30A, 480V, 3PH) IN NEMA 1 ENCLOSURE. PROVIDE (4) #12 & #12 GROUND IN 3/4"C.
CONNECTRAC FLEX RACEWAY SYSTEM. PROVIDE POWER FLOOR DEVICE AND KIT FOR (1) DUPLEX
RECEPTACLE FOR USE WITH IN-CARPET WIREWAY SEGMENT. ELECTRICAL CONTRACTOR SHALL
COORDINATE FLOOR BOX CONFIGURATION AND EXACT LOCATION WITH THE TENANTS
REPRESENTATIVE IN THE FIELD PRIOR TO INSTALLATION. CONTRACTOR SHALL PROVIDE ALL WIRING,
CLIPS, ADHESIVE, SHIELDING, ETC FOR INSTALLATION OF A COMPLETE SYSTEM.
WWW.CONNECTRAC.COM.
ROUTE POWER WIRING AND FLEXIBLE CONDUIT IN WIREWAY FOR RECEPTACLES TO NEAREST FIXED
WALL AND UP TO JUNCTION BOX IN ACCESSIBLE CEILING SPACE.
8'
8
7
7
7
7
14-30R
60
OFFICE
3H36W
COPY
3J36W
POWER FLOOR PLAN
NEW WORK - ELECTRICAL
MORGAN STATE UNIVERSITY SA+P | 47
ARCHITECT / MEP ENGINEER: CONTRACTOR:
REV. NO. DATE
DESCRIPTION
PROJECT MANAGER:
JBG SMITH
6596 SPRINGFIELD CENTER DRIVE
SPRINGFIELD .VA 22150
571-444-0323
PROJECT:
33215 ROOM CONVERSION
3RD FLOOR
6595 SPRINGFIELD CENTER DRIVE
SPRINGFIELD, VA 22150
TITLE
FLOOR PLANS - NEW WORK - ELECTRICAL
PROJECT FILE NAME: LATEST REVISION: ISSUE DATE:
SP95-3CCR
SM: PM:
BY:
GB GB GB
2024 COPYRIGHT Arium AE, LLC E2
DWG NO.
ISSUED FOR 100% REVIEW - DATE: 04-05-2024 - NOT FOR CONSTRUCTION
c
MAR 2023
PLAN
NORTH
EXIT #1
48 |
0
1'
STACKED XFMRS
2' 4'
SCALE 1/4" = 1' - 0"
T
EX. L3WA
EX. L3WB
EX. L3WC
EX. L3WD
EX. L3WE
EX. HM3EA
EX. HM3EB
EX EX EX
CRITICAL DIMENSIONS SHALL NOT BE SCALED
EXISTING CONDITIONS HAVE BEEN PARTIALLY
FIELD VERIFIED BY ARIUM AE.
8'
EX. HL3W
PARTIAL POWER FLOOR PLAN
NEW WORK - ELECTRICAL
ITEM NO.
T75
T112
110A
FSS
KVA RATING
75
112.5
175A
FSS
75KVA
XFMR
112.5KVA
XFMR
O.C.
125A
175A
EX.
PNL
'L3WA"
400A
MCB
PRIMARY CONNECTION
WIRING
(3) # 1 + (1) # 6 GROUND
(3) # 2/0 + (1) # 6 GROUND
EX.
PNL
'L3WB"
400A
MLO
EX.
PNL
'L3WC"
225A
MCB
TRANSFORMER SCHEDULE
CONDUIT
1 1/2"
2"
EX.
PNL
'L3WD"
225A
MLO
EX.
PNL
'L3WE"
225A
MLO
EX.
PNL
'HLWE"
100A
MLO
2
EX.
PNL
'HM3WB"
400A
MLO
1
EX.
PNL
'HM3WA"
400A
MLO
POWER RISER DIAGRAM - EXISTING
NOT TO SCALE
O.C.
250A
400A
SECONDARY CONNECTION
WIRING
(4) #250KCMIL + (1) # 2 GROUND
(4) #500KCMIL + (1) # 1/0 GROUND
CONDUIT
3"
3 1/2"
100A
FSS
400A
FSS
TRANSFORMER SCHEDULE NOTES:
RISER DIAGRAM NOTES:
1
2
EX. 2 SETS OF (4) #3/0 & #3 GROUND IN (2) 2-1/2" C.
EX. (4) #3 & #8 GROUND IN 1-1/4" C.
1. PROVIDE STANDARD N.E.M.A TAPS FOR PRIMARY AND SECONDARY CONNECTIONS.
2. SYSTEM VOLTAGE IS 480 VOLTS TO PRIMARY AND 208Y/120 VOLTS TO SECONDARY.
3. TRANSFORMER RACEWAY FOR ISOLATE GROUND PANELBOARDS SHALL CONTAIN AN ISOLATED GROUND.
(I.G.) CONDUCTOR IN ADDITION TO THE EQUIPMENT GROUNDING CONDUCTOR (E.G.).
4. PRIMARY OVER CURRENT PROTECTION, CONDUIT AND WIRE SHALL BE SAME FOR TRANSFORMER WITH THE SAME KVA RATING.
5. THE GROUNDING ELECTRODE CONDUCTOR (G.E.C) LISTED IN THE TABLES SHALL NOT BE INSTALLED IN THE CONDUITS.
ARCHITECT / MEP ENGINEER: CONTRACTOR:
REV. NO. DATE
DESCRIPTION
PROJECT MANAGER:
JBG SMITH
6596 SPRINGFIELD CENTER DRIVE
SPRINGFIELD .VA 22150
571-444-0323
PROJECT:
33215 ROOM CONVERSION
3RD FLOOR
6595 SPRINGFIELD CENTER DRIVE
SPRINGFIELD, VA 22150
TITLE
ELECTRICAL RISER DIAGRAM AND SCHEDULES
PROJECT FILE NAME: LATEST REVISION: ISSUE DATE:
SP95-3CCR
SM: PM:
BY:
GB GB GB
2024 COPYRIGHT Arium AE, LLC E3
MORGAN STATE UNIVERSITY SA+P | 49
DWG NO.
ISSUED FOR 100% REVIEW - DATE: 04-05-2024 - NOT FOR CONSTRUCTION
c
SPECIFICATIONS
SYMBOLS LIST
GENERAL
1. ALL WORK, EQUIPMENT AND MATERIALS SHALL CONFORM TO THE LATEST APPLICABLE CODES OF THE
AUTHORITY HAVING JURISDICTION, AND ALL APPLICABLE RULES, REGULATIONS, LAWS, AND ORDINANCES
OF FEDERAL AND LOCAL AUTHORITIES. THEY INCLUDE THE FOLLOWING:
LATEST ISSUE OF THE INTERNATIONAL MECHANICAL CODE AND THE PLUMBING CODE
LATEST EDITION OF NFPA-13
OWNERS INSURANCE UNDERWRITER
2. THE SCOPE OF WORK INDICATED ON THESE DRAWINGS SHALL INCLUDE MECHANICAL AND FIRE
PROTECTION SYSTEMS, FULLY TESTED AND READY FOR USE. CONTRACTOR SHALL FURNISH AND
INSTALL ALL NECESSARY COMPONENTS, FITTINGS, HANGERS, SUPPORTS, AND ACCESSORIES
NECESSARY FOR COMPLETE AND SAFE INSTALLATION AND USE OF ALL SYSTEMS INDICATED ON THE
DRAWINGS.
MAR 2023
3. EXISTING CONDITIONS AND SITE EXAMINATIONS:
PRIOR TO SUBMITTING A BID, CONTRACTOR SHALL VISIT THE SITE AND ACQUAINT HIMSELF WITH THE
SITE CONDITIONS.
LAYOUT SHOWN ON THESE DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL ARRANGEMENT FOR
WORK AND SYSTEMS. PRIOR TO THE INSTALLATION, FABRICATION, REMOVAL OR RELOCATION OF ANY
WORK, THE CONTRACTORS SHALL VERIFY ALL DIMENSIONS AND INVERTS IN THE FIELD AND COORDINATE
WITH ALL OTHER TRADES, ARCHITECTURAL PLANS AND BUILDING STRUCTURE. WHERE CONFLICTS
OCCUR, OR IF THE CONNECTIONS CANNOT BE MADE, THE CONTRACTOR SHALL NOTIFY THE ENGINEER
PRIOR TO ANY INSTALLATION AND FABRICATION. COORDINATE ALL EQUIPMENT LOCATION WITH THE
ARCHITECTURAL DRAWINGS. DO NOT SCALE THESE DRAWINGS.
WAIVER OF RESPONSIBILITY OR REQUESTS FOR ADDITIONAL PAYMENT BASED ON LACK OF KNOWLEDGE
OF CONDITIONS AT THE SITE WILL NOT BE ACCEPTED.
CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN THE FIELD AND REPORT EACH DISCREPANCY BEFORE
START OF WORK.
4. QUALITY OF MATERIALS: NEW, BEST OF THEIR KIND, FREE FROM DEFECTS.
5. SHOP DRAWINGS: SUBMIT FOUR (4) COPIES OF SHOP DRAWINGS TO ENGINEERS FOR ALL MECHANICAL
EQUIPMENT, PRIOR TO ORDER, BUILT, OR INSTALLED.
6. CLEARANCES: CONTRACTOR SHALL COORDINATE EQUIPMENT LOCATION AS REQUIRED TO PROVIDE
PROPER CLEARANCES FOR SERVICE AND OPERATION OF THE EQUIPMENT.
7. WIRING: CONTRACTOR SHALL VERIFY ALL VOLTAGE AND POWER REQUIREMENTS AND COORDINATE WITH
ELECTRICAL CONTRACTOR AS REQUIRED. SEE ELECTRICAL DRAWINGS FOR EQUIPMENT POWER
REQUIREMENTS. THE CONTRACTOR SHALL FURNISH AND INSTALL ALL NECESSARY WIRING,
TRANSFORMERS, CONTROLS, HARDWARE, SAFETY DEVICES, AND ACCESSORIES FOR PROPER
INSTALLATION AND OPERATION OF ALL SYSTEMS IN ACCORDANCE WITH MANUFACTURER
RECOMMENDATIONS AND LOCAL CODE REQUIREMENTS.
8. SLAB PENETRATIONS: ALL PENETRATIONS REQUIRED FOR NEW WORK: SLAB PENETRATIONS SHALL BE
X-RAYED AND APPROVED BY MANAGEMENT. NO GROUND PENETRATING RADAR ALLOWED UNLESS
APPROVED BY MANAGMENT. XRAY TO LOCATE REINFORCING BARS, POST TENSIONING CABLES, PIPING
CONDUITS, ETC. ALL SUCH COMPONENTS SHALL BE CLEARLY MARKED ON SLAB SURFACE PRIOR TO
DRILLING. CONTRACTOR SHALL NOT CUT BARS, CABLES, ETC. WITHOUT PRIOR WRITTEN AUTHORIZATION
BY OWNER, AND SHALL REPAIR ANY DAMAGE CAUSED BY CORE DRILLING. NOTIFY THE OWNER PRIOR TO
DRILLING TO ALLOW A FIELD INSPECTION OF CORE LOCATIONS. IN ADDITION ALL PENETRATIONS
THROUGH FLOOR SLABS SHALL BE PROPERLY FIRE STOPPED. COORDINATE WITH STRUCTURAL
ENGINEER AND BUILDING MANAGEMENT.
9. PROVIDE ALL NECESSARY HANGERS FOR SUPPORT OF HORIZONTAL AND VERTICAL PIPING AND
DUCTWORK IN ACCORDANCE WITH THE IMC SECTION 305 AND MANUFACTURERS' RECOMMENDATIONS.
PROVIDE SLEEVES AND ESCUTCHEONS FOR ALL PIPING PASSING THROUGH WALLS OR FLOORS. PIPING
AND DUCTWORK IS TO BE SUPPORTED INDEPENDENTLY SO NO WEIGHT IS SUPPORTED BY THE
EQUIPMENT.
10. ACCESS PANELS: CONTRACTOR SHALL FURNISH AND INSTALL ACCESS PANELS AS REQUIRED PER FIELD
CONDITIONS AND EQUIPMENT REQUIREMENTS. LOCATIONS SHALL BE APPROVED BY THE ARCHITECT.
11. CONTRACTOR SHALL COORDINATE LOCATION OF CONTROLS, GAGES, THERMOMETERS, VALVES, AND
SYSTEM COMPONENTS WITH FIELD CONDITIONS TO PROVIDE PROPER CLEARANCES FOR SERVICE AND
OPERATION OF EQUIPMENT.
12. PROVIDE DIELECTRIC FITTINGS, COUPLINGS, OR FLANGE UNIONS ISOLATING JOINTS ON ALL FERROUS TO
NONFERROUS PIPE CONNECTIONS TO PREVENT AN ELECTROLYTIC ACTION BETWEEN DISSIMILAR
METALS.
13. CONTRACTOR SHALL SEAL ALL UNUSED PENETRATIONS TO MATCH EXISTING FINISH. PROVIDE FIRE
STOP WHERE REQUIRED. ALL LARGE PENETRATIONS THROUGH STRUCTURAL COMPONENTS SHALL BE
SEALED PER THE ARCHITECTS AND STRUCTURAL ENGINEERS INSTRUCTIONS.
14. ENGINEER OR ARCHITECT HAS NOT CONSIDERED THE POTENTIAL PRESENCE OF HAZARDOUS MATERIALS
IN THE DESIGN. SHOULD THE CONTRACTOR DISCOVER ANY POTENTIALLY HAZARDOUS MATERIALS
DURING THE PROCESS OF THE WORK, DO NOT DISTURB IT AND IMMEDIATELY NOTIFY THE OWNER.
15. ALL MOTOR DRIVEN EQUIPMENT SHALL BE INSTALLED WITH VIBRATION ISOLATORS UNLESS OTHERWISE
NOTED. FOLLOW MANUFACTURER'S RECOMMENDED INSTRUCTIONS. PIPING CONNECTED TO VIBRATING
EQUIPMENT SHALL BE ISOLATED BY RESILIENT HANGERS OR FLEXIBLE CONNECTORS. CONNECT
MECHANICAL EQUIPMENT TO DUCTWORK USING RUBBERIZED CANVAS FLEXIBLE CONNECTIONS.
16. UPON THE COMPLETION OF THE INSTALLATION OF EACH SYSTEM, DEMONSTRATE THAT THE SYSTEM
OPERATES PROPERLY IN EACH MODE OF OPERATION. PROVIDE MAINTENANCE AND INSTRUCTION
MANUALS TO THE USER.
17. PIPING SYSTEM IDENTIFICATION: FOR ALL PIPING SYSTEMS WITHIN THE SCOPE OF WORK, IDENTIFY ALL
NEW PIPING (CONCEALED OR EXPOSED) WITH PIPE MARKERS THAT LABEL THE DIRECTION OF FLOW AND
SYSTEM TYPE. ON INSULATED PIPE, INSTALL LABELS OVER INSULATION. PROVIDE A LABEL @ A MINIMUM
OF EVERY 20' AND AT EACH FITTING (BRANCH, VALVE, TEE, ETC).
18. UNLESS OTHERWISE NOTED, INSTALL ALL NEW PIPING AND DUCTWORK AS HIGH AS POSSIBLE (TIGHT TO
THE STRUCTURE).
19. IN A PLENUM RETURN SYSTEM, CONTRACTOR TO VERIFY NO PVC PIPING IS LOCATED WITHIN THE
PLENUM. IF PVC IS LOCATED. CONTRACTOR TO NOTIFY CLIENT PROJECT MANAGER AND REPLACE WITH
PLENUM RATED MATERIAL.
20. PROVIDE COMPLETE AND PROPERLY FUNCTIONING MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE
PROTECTION SYSTEMS AS INTENDED IN THESE DESIGN DOCUMENTS. ALL COMPONENTS AND
EQUIPMENT MUST BE FULLY TESTED, POWERED, INTERLOCKED, ADJUSTED, AND BALANCED BY THE
CONTRACTOR TO ENSURE ALL EQUIPMENT FUNCTIONS THROUGH THEIR FULL OPERATING RANGE IN
COMPLIANCE WITH THE MANUFACTURER'S RECOMMENDATIONS AND CONSTRUCTION DOCUMENTS.
21. MAINTAIN ALL ARCHITECTURAL PARAMETERS INCLUDING CEILING HEIGHT, CHASE WALLS, EQUIPMENT
SCREENS, ROOM SIZES, PARTITION TYPES, INSULATION, ETC. UNLESS PRIOR WRITTEN AUTHORIZATION IS
PROVIDED BY THE ARCHITECT.
22. COORDINATE THE INSTALLATION OF ALL EQUIPMENT AND TRADES TO MAINTAIN ALL MANUFACTURER
REQUIRED SERVICE CLEARANCES AND CLEARANCES REQUIRED BY THE NEC (NATIONAL ELECTRIC
CODE).
23. PROVIDE FIRE AND SMOKE DAMPERS WHERE DUCTWORK PENETRATES FIRE AND SMOKE PARTITIONS AS
NOTED ON DRAWINGS AND REQUIRED PER LOCAL JURISDICTION. DAMPERS SHALL BE UL LISTED.
24. FIRE AND SMOKE DAMPERS: FIRE AND SMOKE DAMPERS SHALL BE PROVIDED WITH AN APPROVED
MEANS OF ACCESS, LARGE ENOUGH TO PERMIT INSPECTION AND MAINTENANCE OF THE DAMPER AND
ITS OPERATING PARTS. THE ACCESS SHALL NOT AFFECT THE INTEGRITY OF FIRE-RESISTANCE-RATED
ASSEMBLIES. ACCESS POINTS SHALL BE PERMANENTLY IDENTIFIED ON THE EXTERIOR BY A LABEL
HAVING LETTERS NOT LESS THAN 0.5 INCH.
25. MANUFACTURERS AND MODEL NUMBERS INDICATED ON THE CONTRACT DRAWINGS SHALL BE FOR
REFERENCE AND BASIS OF DESIGN ONLY. VERIFY ALL EQUIPMENT REQUIREMENTS, PERFORMANCE, AND
ACCESSORIES PRIOR TO ORDERING OF EQUIPMENT. ENGINEER SHALL TAKE NO RESPONSIBILITY FOR
EQUIPMENT THAT IS IMPROPERLY ORDERED OR INSTALLED OR FOR SUBSTITUTED EQUIPMENT WITHOUT
REVIEWING SUBMITTED SHOP DRAWINGS.
50 |
26. CONTRACTOR SHALL INSTALL CONSTRUCTION FILTERS ON ALL RETURN AIR INLETS DURING ALL
CONSTRUCTION ACTIVITY. COORDINATE W/BUILDING MANAGEMENT.
27. PROVIDE ROOF PAVERS TO MATCH BUILDING STANDARD (WHERE APPLICABLE) IN ALL SERVICE AND
MAINTENANCE AREAS FOR NEW ROOF EQUIPMENT AND PIPING.
28. FOR ALL NEW AND RELOCATED EQUIPMENT COORDINATE THE INSTALLATION, MOUNTING
REQUIREMENTS, AND STRUCTURAL MODIFICATIONS REQUIRED WITH A STRUCTURAL ENGINEER
LICENSED IN THE LOCAL JURISDICTION.
29. CONTRACTOR IS RESPONSIBLE FOR THE INSTALLATION OF THE EQUIPMENT AS NOTED ON THE
DRAWINGS. WHEN REQUIRED, CONTRACTOR MUST RELOCATE ANY EXISTING EQUIPMENT, WIRING,
DUCTWORK, CONTROLS, CIRCUITS, PIPING, COMPONENTS, ETC AS NEEDED TO INSTALL NEW EQUIPMENT
AND COMPONENTS. THE DESIGN INTENT OF THE DRAWINGS MUST BE FOLLOWED.
30. ALL NEW MECHANICAL EQUIPMENT AND PIPING SHALL BE PROVIDED WITH A PERMANENT IDENTIFICATION
TAG. COORDINATE IDENTIFICATION W/BUILDING ENGINEER. IF BUILDING ENGINEER HAS NO PREFERENCE
OR IS NOT PRESENT, TAG SHALL BE A MINIMUM OF 2" HIGH, CLEARLY LEGIBLE WITH EQUIPMENT OR PIPE
ID AND FLOW DIRECTION INDICATED. ALL NEW MECHANICAL EQUIPMENT (AHU, VAV, ETC) TO BE
PROVIDED WITH CEILING MARKER. COORDINATE WITH BUILDING MANAGEMENT AND TENANT. MATCH ANY
EXISTING BUILDING STANDARDS.
31. ALL EXISTING EQUIPMENT TO REMAIN SHALL BE TESTED AND BALANCED PRIOR TO ANY CONSTRUCTION
WORK BEING DONE. ANY DEFICIENCIES SHALL BE REPORTED AND A COPY OF THE BALANCING REPORT
SHALL BE GIVEN TO OWNER / MANAGEMENT AND ENGINEER IMMEDIATELY. ALL EXISTING EQUIPMENT TO
REMAIN SHALL BE IN PROPER WORKING ORDER WHEN RETURNED OVER TO OWNER / MANAGEMENT.
32. EACH CONTRACTOR OR SUBCONTRACTOR SHALL KEEP ONE COMPLETE SET OF THE CONTRACT
WORKING DRAWINGS ON THE JOB SITE ON WHICH THEY SHALL REGULARLY RECORD ANY DEVIATIONS OR
CHANGES FROM THE CONTRACT DRAWINGS MADE DURING CONSTRUCTION (RED LINES). THESE
DRAWINGS SHALL RECORD THE LOCATION OF ALL CONCEALED EQUIPMENT, PIPING, ELECTRIC SERVICE,
SANITARY SEWERS, AND OTHER PIPING, BY MEASURED DIMENSIONS TO EACH ITEM FROM READILY
IDENTIFIABLE AND ACCESSIBLE WALLS, CORNERS OF BUILDING, OR COLUMN LINES. PLANS SHALL ALSO
SHOW INVERT ELEVATIONS OF SEWERS AND TOP ELEVATION OF ALL OTHER BELOW GRADE LINES.
RECORD DRAWINGS SHALL BE KEPT CLEAN AND UNDAMAGED AND SHALL NOT BE USED FOR ANY
PURPOSE OTHER THAN RECORDING DEVIATIONS FROM WORKING DRAWINGS AND EXACT LOCATIONS OF
CONCEALED WORK. AFTER THE PROJECT IS COMPLETE, THESE SETS OF DRAWINGS SHALL BE
DELIVERED TO THE ARCHITECT IN GOOD CONDITION AS A PERMANENT RECORD OF THE INSTALLATION
AS ACTUALLY CONSTRUCTED.
INSULATION:
1. TEST RATINGS: SHALL BE IN ACCORDANCE WITH ASTM E84. NFPA # 225 OR UL 723.
2. DUCT AND PLENUM INSULATION (PER IECC): INSULATE ALL NEW SUPPLY AIR DUCTWORK AND PLENUMS WITH
2" THICK 1 1 2 LB (R-8 MINIMUM). ALL OTHER DUCTWORK (INCLUDING EXISTING DUCTS) SHALL BE INSULATED
WITH 2" THICK 1 1 2 LB (R-6 MINIMUM). DENSITY FIBERGLASS BLANKET WITH VAPOR BARRIER JACKET. SEAL ALL
VABOR BARRIER SEAMS WITH A FLEXIBLE SEALANT. ALL DUCTWORK IN OPEN CEILINGS (EXPOSED) SHALL BE
INTERNALLY INSULATED (INCLUDING SUPPLY TAPS). WHERE IT IS NOT POSSIBLE TO INTERNALLY SEAL
DUCTWORK IN EXPOSED CEILINGS, IF SEALANT MUST BE APPLIED ON THE EXTERIOR OF THE DUCT, IT SHALL
BE TAPED AND APPLIED NEATLY. THE TAPE SHALL BE REMOVED AFTER SEALANT APPLICATION. DUCTWORK
THAT IS INTERNALLY LINED DOES NOT REQUIRED EXTERNAL INSULATION.
3. DUCT LINING (SOUND LINING): PROVIDE 1" THICK LINING WITH AN AVERAGE DENSITY OF NOT LESS THAN 2
LB/CU. FT. WHERE SHOWN ON THE DRAWINGS. INSULATION SHOULD BE TREATED WITH AN EPA-REGISTERED
ANTI-MICROBIAL AGENT. PROVIDE SOUND LINING A MINIMUM OF 20' DOWNSTREAM OF ANY FAN-POWERED
VAV BOX OR AHU.
4. ALL PIPING EXPOSED TO THE OUTSIDE SHALL BE PROVIDED WITH AN ALUMINUM JACKET SEALED WATER
TIGHT INSTALLED OVER THE INSULATION.
5. HANGERS FOR INSULATED PIPING SHALL BE PROVIDED WITH INSULATION PROTECTIVE SHEET METAL SHIELD.
HVAC EQUIPMENT
1. DUCTWORK:
ALL DUCTWORK SHALL CONFORM TO THE LATEST ASHRAE AND SMACNA REQUIREMENTS
TYPE: PRESSURE CLASS SEAL CLASS
LOW PRESSURE 2" A
MEDIUM PRESSURE 4" A
RETURN 2" A
OUTSIDE 2" A
EXHAUST 2" A
TRANSFER 1" C
DUCTS AND PLENUMS DESIGNED TO OPERATE AT STATIC PRESSURES EQUAL TO OR GREATER THAN 3
IN. W.G. SHALL BE LEAK TESTED IN ACCORDANCE WITH SMACNA HVAC AIR DUCT LEAKAGE TEST
MANUAL AND SHOWN TO HAVE A RATE OF AIR LEAKAGE (CL) LESS THAN OR EQUAL TO 4.0 AS
DETERMINED IN ACCORDANCE WITH THE FOLLOWING EQUATION: CL=F / (P^0.65); WHERE "F" IS THE
MEASURED LEAKAGE RATE IN CFM PER 100 SF OF DUCT SURFACE, P IS THE STATIC PRESSURE OF
THE TEST. IF A SAMPLE OF TEST DUCTWORK IS FAILS TO MEET THE ALLOTTED LEAKAGE LEVEL, THE
CONTRACTOR SHALL REPAIR OR MODIFY THE CONSTRUCTION OF THE DUCTWORK TO BRING IT INTO
COMPLIANCE AND RETEST UNTIL ACCEPTABLE LEAKAGE IS DEMONSTRATED. TESTS AND NECESSARY
REPAIR SHALL BE COMPLETED PRIOR TO CONCEALMENT OR INSULATING OF DUCTWORK. THE
SAMPLE DUCTWORK SHALL INCLUDE AT LEAST 5 TRAVERSE JOINTS, TYPICAL SEAMS, AN ACCESS
DOOR, AND MINIMUM 2 TYPICAL BRANCH CONNECTIONS PLUS AN ELBOW.
2. FLEXIBLE DUCTWORK:
SHALL BE THE SAME SIZE AS THE DIFFUSER INLET. FLEXIBLE DUCTWORK AND CONNECTIONS SHALL
BE UL CLASS 1 AND NOT BE OVER 8' IN LENGTH. FLEXIBLE DUCTWORK SHALL BE PRE-INSULATED WITH
1" THICK FIBERGLASS INSULATION. FLEXIBLE DUCT SHALL CONFORM TO NFPA 90A AND 90B.
3. VOLUME DAMPERS:
PROVIDE ADJUSTABLE DAMPERS AT ALL LOW PRESSURE DUCTWORK JUNCTIONS AND TAPS ON
SUPPLY, RETURN, AND EXHAUST DUCTWORK.
4. TESTING, ADJUSTING AND BALANCING:
AFTER COMPLETION OF THE HVAC SYSTEM AND PRIOR TO THE ACCEPTANCE BY THE OWNER, ALL
SYSTEMS SHALL BE ADJUSTED AND BALANCED TO DELIVER THE AIR AND WATER QUANTITIES AS
SPECIFIED, INDICATED ON THE DRAWINGS, OR AS DIRECTED. TESTING AGENCY SHALL BE CERTIFIED
BY THE NATIONAL ENVIRONMENTAL BALANCING BUREAU (NEBB).
AIR QUANTITY MEASUREMENTS IN MAIN AND BRANCH DUCTS SHALL BE PERFORMED BY PITOT TUBE
TRAVERSE OF THE ENTIRE CROSS SECTIONAL AREA OF THE DUCT.
FOR AIR-HANDLERS (BASE AND SUPPLEMENTAL) IN SCOPE OF WORK, CONTRACTOR SHALL PROVIDE
THE SUPPLY AIR DISCHARGE TEMPERATURE AND WEATHER CONDITIONS (DB/WB) AT TIME OF SYSTEM
BALANCING.
THE CONTRACTOR SHALL RECORD AND SUBMIT A REPORT TO THE ENGINEER. FOR THEIR
EVALUATION AND APPROVAL OF THE COMPLETE AIR BALANCE REPORT CERTIFIED BY A
PROFESSIONAL ENGINEER.
5. CONTROLS:
EQUIPMENT VENDOR SHALL PROVIDE ALL CONTROLS AND ACCESSORIES NECESSARY TO MEET
REQUIREMENTS AND SEQUENCES. BMS SEQUENCING (IF APPLICABLE) SHALL BE COORDINATED WITH
BUILDING PROJECT MANAGER. CONTRACTOR SHALL UPDATE THE BMS GRAPHICS FOR ALL NEW AND
MODIFIED VAVS AS APPLICABLE. CONTRACTOR SHALL UPDATE THE FLOOR PLAN AND HVAC LAYOUT
GRAPHICS FOR THE NEW LAYOUT.
CONTROL WIRING SHALL BE CONCEALED AND RUN IN CONDUIT. CONDUIT AND FITTINGS EXPOSED TO
THE WEATHER SHALL BE WEATHERPROOF. INSTALL THERMOSTATS @ 48" AFF WHERE ANY OPERABLE
PARTS OF THE THERMOSTAT DO NOT EXCEED 48" AFF, UNLESS OTHERWISE NOTED. THERMOSTAT
LOCATIONS PROVIDED FOR REFERENCE ONLY. THERMOSTATS SHALL NOT BE LOCATED BEHIND
CUBES, FURNITURE, OR DOORS WHEN OPEN. COORDINATE FINAL LOCATIONS WITH FURNITURE AND
ARCHITECTURAL PLANS. LOCATE THERMOSTATS ADJACENT TO SWITCHES IF ON THE SAME WALL.
PROVIDE AN INSULATED SUB-BASE FOR ANY THERMOSTAT MOUNTED ON AN EXTERIOR
WALL/PARTITION. ALL CONTROLS TO BE COMPATIBLE WITH ANY EXISTING BUILDING
MANAGEMENT/CONTROLS SYSTEMS, COORDINATE WITH BUILDING ENGINEER.
IF EXISTING THERMOSTATS ARE NOT BEING REUSED, CONTRACTOR SHALL PROVIDE A NEW WALL
MOUNTED PROGRAMMABLE THERMOSTAT, WITH HEATING AND COOLING OPTION (AS REQUIRED), 24 7
PROGRAMMABLE CLOCK, & TEMPERATURE DISPLAY. EXTENDING WIRING TO EXISTING, NEW, OR
RELOCATED THERMOSTATS SHALL BE INCLUDED IN THE BID. COORDINATE THERMOSTAT CONTROL
REQUIREMENTS WITH FINAL EQUIPMENT SELECTION. THERMOSTATS SHALL BE CAPABLE OF HAVING A
MINIMUM 5 °F DEADBAND BETWEEN HEATING AND COOLING AND NIGHTTIME SET BACK.
6. CEILING DIFFUSERS/REGISTERS:
ALL DIFFUSERS MUST MEET A MAXIMUM OF NC-30.
PROVIDE APPROPRIATE MOUNTING HARDWARE/FRAME PER CEILING TYPE.
PROVIDE VOLUME DAMPERS ON ALL SUPPLY, RETURN, AND EXHAUST TAPS. IF VOLUME DAMPERS
WILL BE INACCESSIBLE AT DUCT TAPS, PROVIDE VOLUME DAMPER AT DIFFUSER NECK OR PROVIDE
CABLE LINKAGE FOR OPENING AND CLOSING THE VOLUME DAMPER AT THE FACE OF THE DIFFUSER.
DIFFUSERS SHALL MATCH BUILDING STANDARD, FINISH TO MATCH OR PROVIDED BY ARCHITECT.
WHERE FACTORY SUPPLY PLENUMS ARE UTILIZED FOR SLOT / FLOWBAR TYPE DIFFUSERS, PLENUM
SHALL BE FACTORY INTERNALLY INSULATED AND SHALL INCLUDE FACTORY INSULATED END CAPS.
PROVIDE TITUS FLEXRIGHT OR EQUAL FOR ALL DIFFUSER / GRILLE CONNECTIONS WITH A FLEX DUCT.
BASIS OF DESIGN:
(CD) SUPPLY DIFFUSER, TITUS MODEL: PAS (UNLESS OTHERWISE NOTED).
(RG) RETURN GRILLE, TITUS MODEL: PAR (UNLESS OTHERWISE NOTED).
(RR) RETURN REGISTER, TITUS MODEL: 350R (UNLESS OTHERWISE NOTED).
(SD) SUPPLY LINEAR SLOTS, TITUS MODEL: TBDI-30 (UNLESS OTHERWISE NOTED). SUPPLY PLENUMS
SHALL BE FACTORY INTERNALLY INSULATED AND SHALL INCLUDE FACTORY INSULATED END CAPS.
(AC) IF / WHERE ACOUSTICAPS ARE CALLED FOR ON THE PLANS, PROVIDE ACOUSTIC DOME W/1"
COTTON BASED LINER AND ACOUSTIC LINEAR STRIPS (REFER TO DETAIL).
TAG: NECK SIZE: CFM : TYPE: SIZE:
CD-10 10"Ø 226-425 SQUARE LOUVERED 24"x24"
24x24 0-1,800 SQUARE PERFORATED 24"x24"
7. REFER TO MECHANICAL SCHEDULES AND DETAILS FOR ADDITIONAL EQUIPMENT
AND SPECIFICATIONS.
HVAC SEQUENCE OF OPERATION:
1. VAV BOX:
SERIES FAN POWERED BOXES SHALL OPERATE CONTINUOUSLY DURING OCCUPIED HOURS. SUPPLY
FANS SHALL CYCLE WHEN FACILITY IS NOT OCCUPIED.
PARALLEL FAN POWERED BOXES SHALL OPERATE TO MAINTAIN SPACE SETPOINTS DURING
OCCUPIED HOURS. SUPPLY FANS SHALL CYCLE WHEN FACILITY IS NOT OCCUPIED.
SINGLE ZONE BOXES SHALL OPERATE TO MAINTAIN SPACE SETPOINTS DURING OCCUPIED HOURS.
BOXES SHALL CYCLE WHEN FACILITY IS NOT OCCUPIED.
VAV BOXES SHALL BE CONTROLLED BY WALL MOUNTED THERMOSTATS. THERMOSTATS SHALL BE
CAPABLE OF ALL REQUIRED FUNCTIONS OF THE VAV BOX THEY ARE CONTROLLING.
CONTROLS VENDOR SHALL INTEGRATE BOXES INTO EXISTING BMS SYSTEM.
THE CONTROLS CONTRACTOR WILL BE REQUIRED TO MODIFY THE BAS GRAPHICS TO INCLUDE THE
UPDATED MEP WORK. THIS SHOULD INCLUDE THE BACKGROUND CADD DRAWINGS FOR ANY
ARCHITECTURAL MODIFICATIONS.
FIRE PROTECTION / SPRINKLER
1. THIS BUILDING HAS AN EXISTING WET PIPE SPRINKLER SYSTEM. EXISTING SYSTEM SHALL BE
MODIFIED TO ACCOMMODATE THE NEW PARTITION AND LIGHTING LAYOUT, AS WELL AS BRINGING
THE EXISTING SYSTEM INTO COMPLIANCE WITH CURRENT CODES AND REGULATIONS.
2. THE SPRINKLER PIPING ENTERING A BUILDING SHALL BE PROPERLY GROUNDED TO MEET ALL NEC
REQUIREMENTS.
3. THE ENTIRE SPACE MUST BE PROTECTED WITH AN AUTOMATIC WET PIPE, SPRINKLER SYSTEM.
MODIFICATIONS TO THE SPRINKLER SYSTEM SHALL BE DESIGNED, INSTALLED, AND TESTED IN
ACCORDANCE WITH THE LATEST APPLICABLE NFPA 13 STANDARDS, AND IN ACCORDANCE WITH ALL
APPLICABLE CODES OF THE AUTHORITY HAVING JURISDICTION.
4. THE SPRINKLER CONTRACTOR SHALL BE RESPONSIBLE FOR THE FINAL DESIGN OF THE NEW
SPRINKLER WORK. THE CONTRACTOR SHALL VERIFY ALL LOCATIONS AND QUANTITIES OF SPRINKLER
HEADS IN THE FIELD AND RELOCATE AND/OR ADD SPRINKLER HEADS WHERE REQUIRED TO PROVIDE
ADEQUATE COVERAGE.
5. THE SPRINKLER CONTRACTOR SHALL FURNISH AND INSTALL ALL NECESSARY PIPING, FITTINGS
SPRINKLER HEADS, VALVES, CONTROLS, HARDWARE, AND ACCESSORIES REQUIRED FOR THE
PROPER INSTALLATION AND OPERATION OF THE SPRINKLER SYSTEM.
6. THE SPRINKLER CONTRACTOR SHALL SUBMIT HYDRAULIC CALCULATIONS AND SHOP DRAWINGS
SHOWING THE INTENDED MODIFICATION TO THE OWNER AND TO THE LOCAL FIRE MARSHAL FOR
APPROVAL BEFORE PROCEEDING WITH THE WORK.
7. PROVISIONS FOR DRAINAGE AND TESTING THE SYSTEM SHALL BE MADE IN ACCORDANCE WITH NFPA
13 AND THE LOCAL FIRE MARSHALS REGULATIONS.
8. PIPING AND FITTINGS: SHALL MATCH BUILDING STANDARDS. ALL FITTINGS AND PIPING SHALL
CONFORM TO THE LATEST NFPA REGULATIONS AND CONFORM TO UL REQUIREMENTS.
9. VALVES: DRAIN AND TEST VALVES SHALL BE BRONZE BODY, SCREW END, GLOBE VALVES.
10. CONTRACTOR SHALL COORDINATE AND MODIFY SPRINKLER SYSTEM (PIPING AND HEADS) TO ALLOW
INSTALLATION OF NEW AND RELOCATED MECHANICAL, ELECTRICAL, AND ARCHITECTURAL
COMPONENTS AND SYSTEMS. PIPING SHALL BE RELOCATED AND INSTALLED TO ALLOW REQUIRED
NEC CLEARANCES AND MAINTENANCE ACCESS TO ALL EQUIPMENT. THE COST OF THE RESOLUTION
OF CONFLICTS SHALL BE RESOLVED AT NO COST TO THE OWNER.
11. IN TILED CEILINGS, SPRINKLER HEADS SHALL BE LOCATED IN THE CENTER OF THE CEILING TILE. IF
THE CEILING TILE IS 2x4 SCORED TO LOOK LIKE 2x2, SPRINKLER HEADS SHALL BE LOCATED IN
CENTER OF 2x2 PORTION OF CEILING TILE. SPRINKLER HEADS IN CORRIDOR AND LARGE OPEN AREAS
SHALL ALIGN. IN EXPOSED CEILINGS, SPRINKLER HEADS SHALL BE TURNED UP. WHERE CEILINGS
ARE REMOVED AND EXPOSED, RAISE SPRINKLER PIPING AS REQUIRED.
12. ALL SPRINKLER PIPING MUST BE A MINIMUM OF 6" ABOVE THE FINISHED CEILING TO ALLOW FOR
LIGHT FIXTURE INSTALLATIONS.
13. SPRINKLER HEADS SHALL MATCH EXISTING BUILDING STANDARDS.
NOTE: SYMBOLS ARE FOR REFERENCE ONLY. NOT ALL ARE USED IN THIS PROJECT.
ABV
AC
AD
AFF
AHJ
AHU
AUTO-D
ATPV
BDD
BFP
BHP
BMS
BP
BTUH
BWV
CFM / C
CLG
CD
CG
CHWR
CHWS
CO
CU
D
DB
DI
EA
EAT
EBB
DRAWING INDEX
M1
M2
M3
FLEX
DUCT
AND
HARD
DUCT
T
H
S BMS
S
S V
S D
S C
#
CO2
FD
VD
SD
- ABOVE
- ACOUSTICAP
- ACCESS DOOR
- ABOVE FINISHED FLOOR
- AUTHORITY HAVING JURISDICTION
- AIR HANDLING UNIT
- AUTO DAMPER
- AUTOMATIC TRAP PRIMER VALVE
- BACK DRAFT DAMPER
- BACKFLOW PREVENTER
- BRAKE HORSEPOWER
- BUILDING MANAGEMENT SYSTEM
- BYPASS DAMPER
- BRITISH THERMAL UNITS PER HOUR
- BACK WATER VALVE
- CUBIC FEET PER MINUTE
- CEILING
- CEILING DIFFUSER/CONDENSATE
DRAIN
- CEILING GRILLE
- CHILLED WATER RETURN
- CHILLED WATER SUPPLY
- CLEAN OUT
- CONDENSING UNIT
- DOWN
- DRY BULB
- INDIRECT WASTE RECEPTOR
- EACH
NEW DUCTWORK
DUCT WITH CAPPED END
DUCTWORK W/ SOUND LINNING (DIMENSIONS
SHOWN = INSIDE CLEAR AREA)
MITERED ELBOW W/TURNING VANES
FIRE DAMPER
VOLUME DAMPER
SMOKE DAMPER
FD/SD COMBINATION FIRE / SMOKE DAMPER
BDD BACK DRAFT DAMPER (BDD)
MOD MOTOR OPERATED DAMPER (MOD)
FLEXIBLE DUCT
AIR TIGHT FITTING / SPIN-IN FITTING
AIR TIGHT FITTING WITH ROUND HARD DUCT
CEILING FAN
THERMOSTAT
HUMIDISTAT
ZONE SENSOR
SWITCH
SWITCH (VARIABLE SPEED)
DUCT MTD SMOKE DETECTOR
CLG MTD SMOKE DETECTOR
NOTE DESIGNATION
CARBON DIOXIDE SENSOR
ABBREVIATIONS LIST
NOTE: ABBREVIATIONS ARE FOR REFERENCE ONLY. NOT ALL ARE USED IN THIS PROJECT.
- ENTERING AIR TEMPERATURE
- ELECTRIC BASEBOARD HEATER
COVER SHEET - MECHANICAL
FLOOR PLANS - MECHANICAL
DETAILS & SCHEDULES - MECHANICAL
EDB
EER
EF
EG
EH
ER
ESP
EWB
EWT
EX
FA
FC
FD
FLA
FPM
FPVAV
GPM
HEX
HP
HWS
HWR
HZ
KW
LBS
LRA
LT
MAX.
MBH
R
D
- ENTERING DRY BULB TEMPERATURE
- ENERGY EFFICIENCY RATIO
- EXHAUST FAN
- EXHAUST AIR GRILLE
- ELECTRIC HEATER
- EXHAUST REGISTER
- EXTERNAL STATIC PRESSURE
- ENTERING WET BULB TEMPERATURE
- ENTERING WATER TEMPERATURE
- EXISTING
- FREE AREA
- FLEXIBLE CONNECTION
- FIRE DAMPER / FLOOR DRAIN
- FULL LOAD AMPS
- FEET PER MINUTE
- FAN POWERED VARIABLE AIR
VOLUME
- GALLONS PER MINUTE
- HEAT EXCHANGER
- HEAT PUMP/HORSEPOWER
- HOT WATER SUPPLY
- HOT WATER RETURN
- HERTZ (CYCLES PER SECOND)
- KILOWATTS
- POUNDS
- LOCKED ROTOR AMPS
- LIGHT TROFFER DIFFUSER
- MAXIMUM
- 1000 BTUH
CD
PCD
ST
G
GS
GR
U
D
C
L
Ø
TC
C.O.
SUPPLY DIFFUSER/REGISTER
RETURN/EXHAUST GRILLE
LINEAR SLOT DIFFUSER
DIRECTION OF AIR FLOW
CONDENSATE DRAIN (CD)
PUMPED COND. DRAIN (PCD)
STORM DRAIN (ST)
GAS PIPE (G)
GLYCOL SUPPLY (GS)
GLYCOL RETURN (GR)
BACKFLOW PREVENTER
PIPE TURNING UP
PIPE TURNING DOWN
CLEANOUT
UNDERCUT
DOOR LOUVER
DUCT RISE
DUCT DROP
DIAMETER
REGULATOR OR PRESSURE REDUCING VALVE
UNION
GAS COCK
TIME CLOCK
MCA
MFS
MHP
MOCP
MOD
MIN.
N
OA
OBD
OED
OPD
OWS
PD
PH
PSI
R
RA
RG
RH
RPM
RR
RTU
SA
SD
SFU
SP
SR
SRR
- MINIMUM CIRCUIT AMPS
- MAXIMUM FUSE SIZE
- MOTOR HORSEPOWER
- MAXIMUM OVER CURRENT
PROTECTION DEVICE
- MOTOR OPERATED DAMPER
- MINIMUM
- NEW
- OUTDOOR AIR
- OPPOSED BLADE DAMPER
- OPEN END DUCT
- OVERLOAD PROTECTION
DEVICE
- OPERATOR WORKSTATION
- PRESSURE DROP
- PHASE
- POUNDS PER SQUARE
INCH
- RELOCATED
- RETURN AIR
- RETURN AIR GRILLE
- RELATIVE HUMIDITY
- REVOLUTIONS PER MINUTE
- RETURN REGISTER
- ROOFTOP UNIT
- SUPPLY AIR
- SMOKE DAMPER / SLOT DIFFUSER
- SUPPLY FIXTURE UNITS
- STATIC PRESSURE
- SUPPLY REGISTER
CFM
ZONE #
TAG #
MAX. PRIMARY CFM
MIN. PRIMARY CFM
KW
FAN CFM
ZONE #
TAG #
MAX. PRIMARY CFM
MIN. PRIMARY CFM
KW
REHEAT CFM
- SUPPLY REGISTER (ROUND DUCT)
AIR FLOW QUANTITY
EXISTING TO REMAIN ITEM
DEMOLISH OR RELOCATE ITEM
NEW ITEM
NEW TO EXISTING CONNECTION
VAV BOX TAG (FAN POWERED)
VAV BOX TAG (SINGLE DUCT)
FAN POWERED VAV BOX
WITH ELECTRIC HEAT
FPVAV-X (X=INLET SIZE)
NON FAN POWERED VAV BOX
WITH ELECTRIC HEAT
VAV-X (X=INLET SIZE)
NON FAN POWERED VAV BOX
WITHOUT ELECTRIC HEAT
VAV-X (X=INLET SIZE)
TA
TAD
TAO
TBV
TC
TSP
TYP
UH
VAV
VB
VD
VEL
VIF
VLT
W/D
WB
WMS
STAMP
- TRANSFER AIR
- TRANSFER AIR DUCT
- TRANSFER AIR OPENING
- TEMPERATURE BLENDING
VALVE
- TIME CLOCK
- TOTAL STATIC PRESSURE
- TYPICAL
- UNIT HEATER
- VARIABLE AIR VOLUME
- VACUUM BREAKER
- VOLUME DAMPER
- VELOCITY
- VERIFY IN FIELD
- VOLTAGE
- WASHER/DRYER
- WET BULB
- WIRE MESH SCREEN
MORGAN STATE UNIVERSITY SA+P | 51
ARCHITECT / MEP ENGINEER: CONTRACTOR:
REV. NO. DATE
DESCRIPTION
PROJECT MANAGER:
JBG SMITH
6596 SPRINGFIELD CENTER DRIVE
SPRINGFIELD .VA 22150
571-444-0323
PROJECT:
33215 ROOM CONVERSION
3RD FLOOR
6595 SPRINGFIELD CENTER DRIVE
SPRINGFIELD, VA 22150
DWG NO.
M1 COVER SHEET - MECHANICAL TITLE
PROJECT FILE NAME: SP95-3CCR
LATEST REVISION: SM: PM:
ISSUE DATE:
BY:
SHW SHW LP
2024 COPYRIGHT Arium AE, LLC ISSUED FOR 100% REVIEW - DATE: 04-05-2024 - NOT FOR CONSTRUCTION
TITLE
DETAILS & SCHEDULES - MECHANICAL
PROJECT FILE NAME: LATEST REVISION: ISSUE DATE:
SP95-3CCR
COPYRIGHT 2024 Arium AE, LLC
SM: PM:
SHW
BY:
SHW LP
c
1
DUCT PENETRATION THROUGH NON - FIRE
RATED WALL - MECHANICAL DETAILS
NOT TO SCALE
SHEETMETAL SAFING ALL
AROUND (MIN. 22 GA.)
ACOUSTIC LINING WHERE
REQUIRED
SECURE SLEEVE
TO SAFIING
SHEETMETAL SLEEVE
(MIN. 22 GA.) ALL AROUND
FOR DUCTS WITH
EXTERNAL INSULATION
METAL STUD
RECTANGULAR OR
ROUND DUCTWORK
EXTERNAL INSULATION
WHERE REQUIRED
INSULATED TIGHT TO
SLEEVE
DRYWALL PARTITION
2
ELEC. HEATING COIL
FAN POWERED VARIABLE
VOLUME BOX
FLEXIBLE CONNECTOR
NOT TO SCALE
STAINLESS STEEL CLAMP
APPLIED TO FLEXIBLE DUCT
INSULATION OUTER JACKET
TO HOLD DUCT TIGHT
AGAINST EQUIPMENT OVER
VAV INLET
DUCT TRANSITION TO VAV
PRIMARY AIR CONNECTION,
SEE PLANS FOR SIZE
FAN POWERED VAV BOX DETAIL
NOTES:
1. ALLOW 3'MIN. CLEARANCE IN FRONT OF ELECTRICAL CONNECTION
PER NEC AND ACCESS PANELS.
2. CONNECT TO EXISTING BUILDING BMS (IF APPLICABLE)
RETURN AIR FILTER
BUILT-IN ATTENUATOR
TRANSITION TO DUCT, SEE
PLANS FOR SIZE
SUPPLY AIR
SOUND-LINED 10' (MIN.)
DOWN STREAM
FLEXIBLE CONNECTOR
TYPICAL FLEXIBLE DUCT CONNECTION DETAIL
5 NOT TO SCALE
STAINLESS STEEL CLAMP -
APPLIED TO FLEXIBLE
DUCT OUTER JACKET TO
HOLD DUCT TIGHT
AGAINST TRUNK DUCT OR
EQUIPMENT
SUPPLY AIR DUCT
8'-0" MAXIMUM
8'-0" MAXIMUM
20 GUAGE X 1" METAL STRAP
FROM STRUCTURE (TYP.)
THRU BOLT
INSULATION
ROUND DUCT
MAX. SAG 1 2" PER FOOT OF
SUPPORT SPACING.
3
TRANSFER DUCT (TAD) DETAIL
NOT TO SCALE
MITERED ELBOW
WITHOUT TURNING
VANES (TYPICAL)
INTERNALLY
SOUND LINED.
L-SHAPED
PLAN VIEW
NO LINE OF SIGHT
SLAB TO SLAB WALL
NOTES:
1. INSTALL THE TRANSFER DUCT (TAD) AS HIGH AS POSSIBLE. COORDINATE THE
POSITION OF THE DUCT RELATIVE TO THE WALL TO AVOID OTHER DUCTWORK,
EQUIPMENT, LIGHT FIXTURES, THE BUILDING STRUCTURE.
2. REFER TO THE FLOOR PLAN FOR DUCT SIZE.
4
CEILING
TYPICAL DIFFUSER CONNECTION DETAIL
NOT TO SCALE
FLEX DUCT MAX. 8'-0"
FLEX DUCT SIZE SHALL
MATCH NECK SIZE
STAINLESS STEEL CLAMP APPLIED
TO FLEXIBLE OUTER INSULATION
JACKET TO HOLD TIGHT AGAINST
DIFFUSER
NOTE:
1. INSTALL ONLY IF BRANCH HAND DAMPER
IS NOT ACCESSIBLE.
OPPOSED BLADE
DAMPER
(SEE NOTE #1)
DIFFUSER NECK DIAMETER
TOTAL AIR QUANTITY, CUBIC
FEET PER MINUTE (CFM)
CEILING DIFFUSER
DIFFUSER KEY:
CD-8
200
FLEXIBLE DUCT OUTER INSULATION
TO BE HELD TIGHT AGAINST DUCT.
SECURE TIGHT WITH DRAW BAND.
HAND DAMPER TO BE ACCESSIBLE
THROUGH INSULATION.
(2)CD-8
200 EA
SUPPLY DUCT
COLLAR
DRAW BAND - PROVIDE 1
OVER LINER AND 1 OVER
INSULATION JACKET
QUANTITY OF DIFFUSERS
WITH THE SAME CFM.
DIFFUSER NECK DIAMETER
HAND DAMPER SHALL
BE ACCESSIBLE
THROUGH INSULATION.
TOTAL AIR QUANTITY, CUBIC FEET PER
MINUTE (CFM) FOR EACH DIFFUSER.
ARCHITECT / MEP ENGINEER: CONTRACTOR:
REV. NO. DATE
DESCRIPTION
PROJECT MANAGER:
JBG SMITH
6596 SPRINGFIELD CENTER DRIVE
SPRINGFIELD .VA 22150
571-444-0323
STAINLESS STEEL
CLAMP - APPLIED TO
FLEXIBLE DUCT LINER
FLEXIBLE INSULATED
DUCTWORK
NOTES:
1. FLEXIBLE DUCT SHOULD EXTEND STRAIGHT FOR SEVERAL INCHES FROM
RECTANGULAR DUCT CONNECTION BEFORE BENDING
2. FLEXIBLE DUCT SHOULD NOT EXCEED 8'-0" IN LENGTH. USE RIGID ROUND
DUCTWORK WHEN ROUNDOUTS EXCEED 8'-0".
PROJECT:
33215 ROOM CONVERSION
3RD FLOOR
6595 SPRINGFIELD CENTER DRIVE
SPRINGFIELD, VA 22150
MAR 2023
52 |
MORGAN STATE UNIVERSITY SA+P | 53
M3
DWG NO.
ADDITIONAL WORKS
ARCHITECTURAL PHOTOGRAPHY
54 | MORGAN STATE UNIVERSITY SA+P | 55
The Charles
The Charles in Baltimore, a captivating blend of architectural
innovation and historical charm, stands as a testament to urban
GEORGE PEABODY LIBRABY
revitalization. Its repurposed grandeur marries the past with the
present, reimagining a former theater as a modern cultural hub. As
an architectural photographer, entering The Charles is a sensory
journey through time and design. The ornate, meticulously restored
façade greets you with its timeless elegance, while the interior boasts
a harmonious marriage of contemporary minimalism and vintage
opulence. The juxtaposition of sleek lines and antique details invites
a sense of wonder, like stepping into a living work of art. Sunlight
streams through arched windows, casting soft, cinematic shadows
on polished surfaces. The ambiance is a symphony of historical
resonance and contemporary allure, providing an extraordinary
canvas for visual storytelling and artistic exploration.
The George Peabody Library in Baltimore is a magnificent
architectural masterpiece that combines neoclassical splendor
with scholarly reverence. For an architectural photographer, it is
a place of historical significance and intellectual inspiration. The
library’s towering atrium is adorned with ornate iron balconies
and a captivating skylight that bathes the space in a soft, ethereal
glow. Antique books fill the shelves, creating a symphony of
knowledge that seems to ascend toward the heavens. The library
exudes a sense of quiet reverence, inviting visitors to explore its
meticulously preserved collection of rare books in hushed awe.
Every aspect of this sanctuary is thoughtfully designed, providing
photographers with a rich visual canvas where light and shadow
enhance the architectural details.
56 |
MORGAN STATE UNIVERSITY SA+P | 57
Mt. Vernon Place United
Methodist Church
Mt. Vernon Place United Methodist Church in Baltimore is a
magnificent architectural wonder that commands attention with
its neo-Gothic design, soaring vaulted ceilings, and stained glass
illumination. As an architectural photographer, entering this
sacred space feels like stepping into a time capsule of divine
inspiration. The interior’s interplay of light and shadow, intricate
wooden pews, and heavenly acoustics create a profound sense of
reverence. Capturing the church’s essence through photography
is a privilege, allowing one to convey the deep appreciation for
the divine craftsmanship that defines this sacred place.
SCAN TO CONNECT
EMAIL:SHROB37@MORGAN.EDU
PHONE:240-521-3575
58 |
MORGAN STATE UNIVERSITY SA+P | 59