VTA Hydroprompt FORTE Folder EN
Effective reduction of bacterial contamination with VTA Hydroprompt® FORTE Discover all the details of VTA Hydroprompt® FORTE now: https://vta.cc/en/products/system-products/vta-hydroprompt-forte
Effective reduction of bacterial contamination with VTA Hydroprompt® FORTE
Discover all the details of VTA Hydroprompt® FORTE now:
https://vta.cc/en/products/system-products/vta-hydroprompt-forte
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>VTA</strong><br />
<strong>Hydroprompt</strong> ®<br />
<strong>FORTE</strong><br />
The multifunctional physically acting<br />
product for improving the performance<br />
of wastewater treatment plants<br />
1
<strong>VTA</strong> <strong>Hydroprompt</strong> ® <strong>FORTE</strong><br />
<strong>VTA</strong> <strong>Hydroprompt</strong> ® <strong>FORTE</strong> is the result of many<br />
years of research and development at our biophysical<br />
laboratories in close cooperation with<br />
universities and colleges.<br />
The multifunctional product increases the degradation capacity of<br />
wastewater treatment plants and, due to its physical properties, causes<br />
the removal of remaining germs in the discharge from the plant.<br />
Increase in<br />
degradation capacity<br />
Inlet<br />
Primary clarifier<br />
Increase in<br />
operational reliability<br />
Effective reduction of<br />
the residual germ load<br />
<strong>VTA</strong> <strong>Hydroprompt</strong> ® <strong>FORTE</strong> is added to the<br />
discharge from the activated sludge tank.<br />
Activated sludge tank<br />
Return sludge<br />
Secondary clarifier<br />
Discharge<br />
2
The unique composition enables a wide<br />
range of applications and can be used<br />
individually according to requirements.<br />
ADVANTAGES<br />
Increase in degradation<br />
capacity for carbon,<br />
nitrogen and phosphorus<br />
compounds<br />
Increased operational<br />
reliability by improving the<br />
sedimentation properties<br />
of the activated sludge<br />
Effective reduction of the<br />
residual germ load in the<br />
discharge from the treatment<br />
plant at extremely<br />
low dosages<br />
Efficient flocculation:<br />
formation of stable<br />
macrofloc<br />
Potential savings in<br />
precipitant consumption<br />
Minimisation of the germ<br />
load in aerosols from the<br />
activated sludge tank<br />
Without<br />
<strong>VTA</strong> <strong>Hydroprompt</strong> ® <strong>FORTE</strong><br />
With<br />
<strong>VTA</strong> <strong>Hydroprompt</strong><br />
® <strong>FORTE</strong><br />
With the use of <strong>VTA</strong> <strong>Hydroprompt</strong> ® <strong>FORTE</strong>, a significant reduction in the residual<br />
germ load in the discharge from the wastewater treatment plant can be observed.<br />
3
The multifunctional mechanism of action of<br />
<strong>VTA</strong> <strong>Hydroprompt</strong> ® <strong>FORTE</strong> produces an increase in performance,<br />
improving ing the operational reliability ility of wastewater w ater treatment plants.<br />
Operational reliability in<br />
wastewater w ater treatment plants<br />
has a name<br />
<strong>VTA</strong> <strong>Hydroprompt</strong> ® <strong>FORTE</strong><br />
SEDIM<strong>EN</strong>TATION CURVE<br />
ACTIVATED SLUDGE<br />
100<br />
80<br />
Sludge limit /<br />
height of measuring<br />
cylinder [%]<br />
Dilution factor: 3<br />
Zero sample<br />
<strong>VTA</strong> <strong>Hydroprompt</strong> ® <strong>FORTE</strong><br />
50ppm<br />
40<br />
20<br />
0 1 2 3 4 5<br />
Reading time [min]<br />
100%<br />
REDUCTION OF PARTICLES<br />
Minimisation of fine suspended solids<br />
in the clear water phase<br />
< 5µm in the discharge<br />
4<br />
Discharge reference sample<br />
0%<br />
91,9%<br />
<strong>VTA</strong> <strong>Hydroprompt</strong> ® <strong>FORTE</strong>
Analysis of data from<br />
a series of practical applications<br />
REDUCTION OF THE RESIDUAL GERM LOAD<br />
The addition of <strong>VTA</strong> <strong>Hydroprompt</strong><br />
® <strong>FORTE</strong> to the discharge from the activated<br />
sludge tank causes a significant reduction in the residual germ load in the<br />
discharge from the treatment plant as compared to the initial situation.<br />
100<br />
relative<br />
e<br />
germ reduction<br />
[%]<br />
0<br />
97,9%<br />
Total germ count<br />
98,6%<br />
MICROBIOLOGICAL ANALYSIS<br />
98,3%<br />
Escherichia<br />
coli<br />
Acinetobacter<br />
baumannii<br />
Dosage of ≤ 50ppm <strong>VTA</strong> <strong>Hydroprompt</strong> ® <strong>FORTE</strong> in the discharge<br />
from the activated sludge tank<br />
93,0%<br />
99,0%<br />
Enterobacteriaceae<br />
Staphylococci<br />
On request, the <strong>VTA</strong><br />
Institute for Health<br />
& Environment can<br />
provide you with help<br />
and support with the<br />
practical use of <strong>VTA</strong><br />
<strong>Hydroprompt</strong> ® <strong>FORTE</strong>.<br />
-60%<br />
Additional molecular biological analysis also shows a reduction of<br />
up to 99% in the residual virus load of noroviruses, rotaviruses and<br />
SARS-CoV-2 viruses through the use of <strong>VTA</strong> <strong>Hydroprompt</strong> ® <strong>FORTE</strong>.<br />
The results of external analyses confirm the in-house results. 1<br />
100<br />
100<br />
Another positive feature of<br />
<strong>VTA</strong> <strong>Hydroprompt</strong> ® <strong>FORTE</strong><br />
relative<br />
reduction<br />
[%]<br />
99,9%<br />
99,6%<br />
qualitative<br />
reduction rate<br />
[%]<br />
85,7%<br />
is the reduction by around<br />
60% of the germ load in<br />
aerosols from the activated<br />
sludge tank.<br />
0<br />
Rotavirus es N orovirus es<br />
0<br />
SARS-CoV-2<br />
MOLECULAR BIOLOGICAL ANALYSIS<br />
Dosage of ≤ 50ppm <strong>VTA</strong> <strong>Hydroprompt</strong> ® <strong>FORTE</strong> in the discharge from the activated sludge tank<br />
5<br />
1<br />
The analysis reports from external laboratories are available at the <strong>VTA</strong> Institute for<br />
Health and Environment.
The possible scope of microbiological and molecular biological<br />
support by the <strong>VTA</strong> Institute for Health and Environment includes:<br />
Sampling by trained personnel<br />
Microbiological and molecular biological analysis<br />
Evaluation and assessment of results<br />
Report / summary of results in electronic and printed format<br />
I n addition to sci entif ic rese arch a nd pr oduct developm ent, the VT A I nst itute f or<br />
H ealth a nd E nvironm ent is de dicated in pa rticular to w as tew ater analy s is and its<br />
f urthe r developm ent, w ith a f ocus o n dem onst rating t he im pr ovem ent in pe rf orm ance<br />
and reduction of the ge rm load at w as tew ater treatm ent pl ants .<br />
6
At our laboratories,<br />
which work to the<br />
highest standards,<br />
the <strong>VTA</strong> Institute for<br />
Health & Environment<br />
offers the following<br />
methods:<br />
MICROBIOLOGICAL<br />
METHODS<br />
AEROSOL MEASUREM<strong>EN</strong>T<br />
Determination of aerosol quantity using<br />
the TSI8530 DustTrak II desktop aerosol<br />
monitor and aerosol sampling using the<br />
MicroFlow ALFA air sampler.<br />
Microbiological germ analysis using<br />
universal and selective agar culture media.<br />
Microbiological germ analysis using selective<br />
liquid culture media with quantitative<br />
colony count using the Quanti-Tray method<br />
Quantitative particle determination<br />
(< 5µm) using the CASY cell counting system<br />
MOLECULAR BIOLOGICAL<br />
METHODS<br />
Molecular biological detection of viral RNA /<br />
DNA and antibiotic resistance genes of<br />
bacterial origin in water samples using the<br />
TFX96 Touch real-time PCR system.<br />
DETERMINATION OF<br />
DRUG RESIDUES<br />
Qualitative / semi-quantitative analyses<br />
of water samples for specific drug classes<br />
using Supelco Visiprep solid phase extraction<br />
through SupelMIP columns and<br />
IMPL<strong>EN</strong> NP80 Mobile NanoPhotometer ®<br />
measurements.<br />
7
We clean water.<br />
<strong>VTA</strong> Austria GmbH<br />
<strong>VTA</strong> Technologie GmbH<br />
Umweltpark 1<br />
A-4681 Rottenbach<br />
Phone: +43 7732 4133<br />
<strong>VTA</strong> Deutschland GmbH<br />
Henneberger Str. 1<br />
D-94036 Passau<br />
Phone: +49 851 988 98-0<br />
<strong>VTA</strong> Schweiz GmbH<br />
Kalchbühlstrasse 40<br />
CH-7000 Chur<br />
Phone: +41 81 252 27-09<br />
<strong>VTA</strong> Česká republika spol. s r.o.<br />
Větrná 1454/72<br />
CZ-37005 České Budějovice<br />
Phone: +420 385 514 747<br />
www.vta.cc<br />
vta@vta.cc<br />
8