ExFeel ®<br />

Internal<br />

<strong>exklusiv</strong> <strong>bei</strong> <strong>ISG</strong> <strong>Dental</strong> <strong>Gmbh</strong><br />

<strong>ISG</strong> DENTAL GmbH<br />

<strong>ISG</strong><br />

<strong>Dental</strong>handel,<br />

DENTAL GmbH<br />

Ordinationsbau & Beratung<br />

Tel.: +43/1/869 32 20 Fax: +43/1/869 32 30<br />

<strong>Dental</strong>handel, Ordinationsbau & Beratung<br />

Tel.: +43/1/869 32 20 Fax: +43/1/869 32 30<br />

zentrale@isg-gmbh.at www.isg-gmbh.at<br />

zentrale@isg-gmbh.at www.isg-gmbh.at


Multifunctional Mount<br />

Fixture Design<br />

Profile Diameter = ø 4.8<br />

Thread Diameter<br />

Taper<br />

Straight<br />

Post Height = 5.5 mm<br />

Abutment Cuff Height = 1.0 mm<br />

D3.13 Octa-Anti-Rotation<br />

Structure Compatible<br />

with ITI SynOcta<br />

Cuff Height<br />

= 1.2 / 2.2 mm<br />

Body Length /<br />

Super RBM Surface<br />

ExFeel<br />

Excellent Feeling, Excellent Implant!<br />

® Internal<br />

Design: The transgingival cuff of 1.2mm and 2.2mm successfully translates<br />

into a single stage surgery that provides excellent gingival adaptation with<br />

quick and easy restorations. Initial stability in any bone quality is guaranteed<br />

by the 1.25 degree thread pitch. The body of this implant comes in a straight<br />

or tapered design, which enhances initial stability.<br />

Surface: Our Super RBM Surface Treatment produces a favorable surface<br />

topography that has been proven through extensive systematic testing.<br />

MegaGen‘s Super RBM Surface shortens loading time and provides favorable<br />

results in any bone quality.<br />

Feature: The multi-functional mount has a titanium nitrate surface coating<br />

that produces a gold color for favorable aesthetic results. This mount is used<br />

for fixture placement and then as a final abutment for cement retained cases.<br />

Surgery: Minimal drilling is required to complete the surgical aspect of this<br />

single stage implant. Our drilling procedure ensures atraumatic surgery. The<br />

ExFeel surgical kit provides ideal stability in any surgical situation.<br />

Prosthetics: We offer many convenient abutment types for the ExFeel Internal<br />

implant. Included in this are the traditional solid abutment, the octa<br />

abutment, and the solid post abutment, among others. We incorporate our<br />

state-of-the-art manufacturing techniques to deliver a secure 8° morse taper,<br />

which allows for excellent aesthetic and functional prosthetic results.<br />

Packaging: A: Fixture with Healing Abutment<br />

B: Fixture, Healing Abutment, Multi Post and Abutment Screw<br />

Small Regular Wide<br />

Transgingival Cuff 2.2 2.2 1.2 2.2 1.2 2.2 1.2<br />

Thread Diameter Ø3.5 Ø4.1 Ø4.8 Ø5.5<br />

Body Length 7 / 8.5 / 10 / 11.5 / 13 mm<br />

A<br />

B<br />

ITDB3507<br />

ITDB3508<br />

ITDB3510<br />

ITDB3511<br />

ITDB3513<br />

ITDB3507P<br />

ITDB3508P<br />

ITDB3510P<br />

ITDB3511P<br />

ITDB3513P<br />

Transgingival Cuff 2.2 2.2 1.2 2.2 1.2 2.2 1.2<br />

Thread Diameter Ø3.5 Ø4.1 Ø4.8 Ø5.5<br />

Body Length 7 / 8.5 / 10 / 11.5 / 13 mm<br />

A<br />

B<br />

ISDB3507<br />

ISDB3508<br />

ISDB3510<br />

ISDB3511<br />

ISDB3513<br />

ISDB3507P<br />

ISDB3508P<br />

ISDB3510P<br />

ISDB3511P<br />

ISDB3513P<br />

SEM(X1000)<br />

Super - RBM Surface<br />

ITDB4107<br />

ITDB4108<br />

ITDB4110<br />

ITDB4111<br />

ITDB4113<br />

ITDB4107P<br />

ITDB4108P<br />

ITDB4110P<br />

ITDB4111P<br />

ITDB4113P<br />

ISDB4107<br />

ISDB4108<br />

ISDB4110<br />

ISDB4111<br />

ISDB4113<br />

ISDB4107P<br />

ISDB4108P<br />

ISDB4110P<br />

ISDB4111P<br />

ISDB4113P<br />

ITDB4107E<br />

ITDB4108E<br />

ITDB4110E<br />

ITDB4111E<br />

ITDB4113E<br />

ITDB4107EP<br />

ITDB4108EP<br />

ITDB4110EP<br />

ITDB4111EP<br />

ITDB4113EP<br />

ISDB4107E<br />

ISDB4108E<br />

ISDB4110E<br />

ISDB4111E<br />

ISDB4113E<br />

ISDB4107EP<br />

ISDB4108EP<br />

ISDB4110EP<br />

ISDB4111EP<br />

ISDB4113EP<br />

ITDB4807<br />

ITDB4808<br />

ITDB4810<br />

ITDB4811<br />

ITDB4813<br />

ITDB4807P<br />

ITDB4808P<br />

ITDB4810P<br />

ITDB4811P<br />

ITDB4813P<br />

ISDB4807<br />

ISDB4808<br />

ISDB4810<br />

ISDB4811<br />

ISDB4813<br />

ISDB4807P<br />

ISDB4808P<br />

ISDB4810P<br />

ISDB4811P<br />

ISDB4813P<br />

ITDB4807E<br />

ITDB4808E<br />

ITDB4810E<br />

ITDB4811E<br />

ITDB4813E<br />

ITDB4807EP<br />

ITDB4808EP<br />

ITDB4810EP<br />

ITDB4811EP<br />

ITDB4813EP<br />

ISDB4807E<br />

ISDB4808E<br />

ISDB4810E<br />

ISDB4811E<br />

ISDB4813E<br />

ISDB4807EP<br />

ISDB4808EP<br />

ISDB4810EP<br />

ISDB4811EP<br />

ISDB4813EP<br />

ITDB5507<br />

ITDB5508<br />

ITDB5510<br />

ITDB5511<br />

ITDB5513<br />

ITDB5507P<br />

ITDB5508P<br />

ITDB5510P<br />

ITDB5511P<br />

ITDB5513P<br />

ISDB5507<br />

ISDB5508<br />

ISDB5510<br />

ISDB5511<br />

ISDB5513<br />

ISDB5507P<br />

ISDB5508P<br />

ISDB5510P<br />

ISDB5511P<br />

ISDB5513P<br />

ITDB5507E<br />

ITDB5508E<br />

ITDB5510E<br />

ITDB5511E<br />

ITDB5513E<br />

ITDB5507EP<br />

ITDB5508EP<br />

ITDB5510EP<br />

ITDB5511EP<br />

ITDB5513EP<br />

ISDB5507E<br />

ISDB5508E<br />

ISDB5510E<br />

ISDB5511E<br />

ISDB5513E<br />

ISDB5507EP<br />

ISDB5508EP<br />

ISDB5510EP<br />

ISDB5511EP<br />

ISDB5513EP<br />

7.0 mm<br />

8.5 mm<br />

10.0 mm<br />

11.5 mm<br />

13.0 mm<br />

7.0 mm<br />

8.5 mm<br />

10.0 mm<br />

11.5 mm<br />

13.0 mm<br />

7.0 mm<br />

8.5 mm<br />

10.0 mm<br />

11.5 mm<br />

13.0 mm<br />

7.0 mm<br />

8.5 mm<br />

10.0 mm<br />

11.5 mm<br />

13.0 mm


5<br />

Lindermann<br />

Drill<br />

Drill<br />

Extension<br />

TEEL200M MDE150<br />

6<br />

Taper Type: Shaping Drill<br />

10<br />

7 13<br />

8.5 15<br />

11.5<br />

Straight Type: Straight Drill<br />

10<br />

7 13<br />

8.5<br />

11.5<br />

Handpiece Connector Ratchet Extension<br />

Ø2.0 Stopper Drill<br />

<strong>ISG</strong> DENTAL GmbH<br />

<strong>Dental</strong>handel, Ordinationsbau & Beratung<br />

Tel.: +43/1/869 32 20 Fax: +43/1/869 32 30<br />

zentrale@isg-gmbh.at www.isg-gmbh.at<br />

7.0 8.5 10 11.5<br />

7.0 8.5 10 11.5<br />

STEP 2: Countersinking<br />

Counter sinking is required for the 4.1 diameter<br />

implant which comes with a 1.2 mm transgingival<br />

cuff.<br />

Ø2.8 Stopper Drill<br />

TEED2007 TEED2010 TEED2807 TEED2810<br />

mm<br />

TEED2008 TEED2011 TEED2808 TEED2811<br />

STEP 1: Shaping & Straight Drilling<br />

Follow drilling sequence according to fixture<br />

diameter in order to create the osteotomy.<br />

STEP 3: Tapping<br />

In type 1 (dense bone), pre-tapping of site may be<br />

required.<br />

STEP 4: Fixture Placement<br />

Use the handpiece connector to place the fixture.<br />

At this point, you may use a ratchet wrench to<br />

complete placement, if necessary.<br />

7<br />

Hand<br />

Driver<br />

TCMHDL1200 or<br />

TCMHDS1200<br />

Removal<br />

Driver<br />

MVD100<br />

Direction<br />

Indicator<br />

MDI100<br />

© 2010 <strong>ISG</strong> <strong>Dental</strong> GmbH - alle Rechte vorbehalten. Vorbehaltlich Druck- und Satzfehler.


1<br />

2<br />

3<br />

Lance Drill<br />

MGD100L<br />

55<br />

Twist Drill<br />

Ø2.0<br />

TEED200M<br />

Small Regular Wide<br />

66<br />

Shaping Drill Straight Drill<br />

1<br />

Ø2.8<br />

TEIS280M<br />

MTP350 MTP410 MTP410 MTP480 MTP550<br />

Ø3.5<br />

Ø3.5<br />

MRIW 100<br />

SG II ExFeel Internal Surgical Kit<br />

Ø2.8<br />

TEED280M<br />

Ø3.5<br />

33<br />

Shaping Drill<br />

Ø3.5<br />

TEIS350M<br />

2<br />

MCS375<br />

Ø4.1 Ø4.1 Ø4.8 Ø5.5<br />

Ø4.1<br />

Straight Drill<br />

Ø3.5<br />

TEED350M<br />

MCS375<br />

M RW040S<br />

Shaping Drill<br />

Ø4.3<br />

TEIS430M<br />

1.2 Cuff 1.2 Cuff 1.2 Cuff<br />

Ø4.1<br />

Ø4.8<br />

44<br />

Straight Drill<br />

77<br />

44<br />

Ø4.3<br />

TEED430M<br />

Ø4.8<br />

Shaping Drill<br />

4<br />

4<br />

Ø4.8<br />

TEIS480M<br />

Ø5.5<br />

PRE-MOUNT<br />

HP Connector<br />

/ Ratchet Extension<br />

MMHC250S<br />

MMHC250U<br />

MTHC200S<br />

MTHC200L<br />

Straight Drill<br />

Ø4.8<br />

TEED480M<br />

1.2 Cuff 1.2 Cuff 1.2 Cuff<br />

Ø5.5<br />

NO-MOUNT<br />

MTRD100S<br />

MTRD100L<br />

HP Connector<br />

/ Ratchet Extension<br />

MOHD300S<br />

MOHD310<br />

© 2010 <strong>ISG</strong> <strong>Dental</strong> GmbH - alle Rechte vorbehalten. Vorbehaltlich Druck- und Satzfehler.


ExFeel ® Internal | Abutments<br />

Cover Screw & Closing Screw<br />

Cover Screw:<br />

The height of cover screw is 1.5 mm.<br />

Closing Screw:<br />

Component to protect inner screw hole.<br />

Using: 1.2 Hex Hand driver<br />

(TCMHDL1200 or TCMHDS1200) or<br />

1.2 Hex Right angle driver (MDR120)<br />

Screw REF-Code<br />

Cover Screw IRC100<br />

Closing Screw ICS200<br />

Impression Coping<br />

Non-Octa Octa Octa Octa<br />

Transfer Type<br />

Octa Type - included<br />

Transfer 10 mm Guide pin<br />

Pick-Up Type<br />

Octa Type - included<br />

Pick-Up 15 mm Guide pin<br />

Using: 1.2 Hex Hand driver<br />

(TCMHDL1200 or TCMHDS1200) or<br />

1.2 Hex Right angle driver (MDR120)<br />

Type REF-Code Guide Pin<br />

Transfer<br />

Non-Octa EXIC002<br />

Octa EXIC003T REIG100<br />

Pick-Up Octa EXIC001T EXICG100<br />

<strong>ISG</strong> DENTAL GmbH<br />

<strong>Dental</strong>handel, Ordinationsbau & Beratung<br />

Tel.: +43/1/869 32 20 Fax: +43/1/869 32 30<br />

zentrale@isg-gmbh.at www.isg-gmbh.at<br />

Healing Abutment<br />

height<br />

Healing Abutment:<br />

To make cuff longer<br />

than 2.2<br />

Using: 1.2 Hex Hand driver<br />

(TCMHDL1200 or TCMHDS1200) or<br />

1.2 Hex Right angle driver (MDR120)<br />

height REF-Code<br />

2.0 mm IRH502<br />

3.0 mm IRH503<br />

4.0 mm IRH504<br />

Lab Analog<br />

Lab Analog:<br />

Component to duplicate platform in<br />

working model to make prosthetics<br />

inner form REF-Code<br />

Octa EXIA001<br />

© 2010 <strong>ISG</strong> <strong>Dental</strong> GmbH - alle Rechte vorbehalten. Vorbehaltlich Druck- und Satzfehler.


ExFeel ® Internal | Abutments<br />

Multi-Mount<br />

Gold Abutment<br />

Octa<br />

Octa<br />

Non-Octa<br />

Multi-Mount & Screw:<br />

1. Mount function during<br />

placement of fixture<br />

2. EZ post function when<br />

making prosthetic<br />

Multi Post Screw:<br />

Included EXIMS100<br />

Using: 1.2 Hex Hand driver<br />

(TCMHDL1200 or TCMHDS1200) or<br />

1.2 Hex Right angle driver (MDR120)<br />

Multi-Mount Screw<br />

Profile diameter Ø5.5 mm 2.0 mm x 0.40pitch<br />

EXIM001 EXIMS100<br />

Cuff height = 1.0/2.0/3.0/4.0<br />

UCLA Gold Abutment:<br />

Gold casting abutment After Wax up<br />

in Plastic sleeve. Burn out temperature<br />

of Plastic Sleeve: 333°<br />

Multi Post Screw:<br />

Included EXIMS100<br />

Using: 1.2 Hex Hand driver<br />

(TCMHDL1200 or TCMHDS1200) or<br />

1.2 Hex Right angle driver (MDR120)<br />

Connecting Torque 20N/<br />

Removeable Torque 10.34N<br />

REF Code Screw<br />

Octa Non-Octa 2.0 mm x 0.40pitch<br />

EXIGA200T EXIGA100T EXIMS100<br />

<strong>ISG</strong> DENTAL GmbH<br />

<strong>Dental</strong>handel, Ordinationsbau & Beratung<br />

Tel.: +43/1/869 32 20 Fax: +43/1/869 32 30<br />

zentrale@isg-gmbh.at www.isg-gmbh.at<br />

Angeled Abutment<br />

15° 25°<br />

Octa<br />

Solid Plastic Coping<br />

Angeled Abutment:<br />

Abutment for incisor teeth<br />

Angeled Abutment Screw:<br />

Included IAAS600<br />

Using: 1.2 Hex Hand driver<br />

(TCMHDL1200 or TCMHDS1200) or<br />

1.2 Hex Right angle driver (MDR120)<br />

REF Code Screw<br />

15° 25° 2.0 mm x 0.40pitch<br />

IAA3515T IAA3525 IAAS600<br />

Please use screw for angled Abutment<br />

Using: 1.2 Hex Hand driver<br />

(TCMHDL1200 or TCMHDS1200) or<br />

1.2 Hex Right angle driver (MDR120)<br />

Bridge-Type Single-Type<br />

Plastic sleeve white Plastic sleeve red<br />

ISPB100 ISPS100<br />

Using in case of lack of esthetic,<br />

path, space<br />

© 2010 <strong>ISG</strong> <strong>Dental</strong> GmbH - alle Rechte vorbehalten. Vorbehaltlich Druck- und Satzfehler.


ExFeel ® Internal | Abutments<br />

Solid Post Abutment & Post Cap<br />

PH<br />

CH<br />

Solid Post Abutment Solid Post Cap<br />

Using: Solid Post Driver (MSD430S/L)<br />

Height Abut. Cuff=1 Abut. Cuff=2 Abut. Cuff=3 Cap Cuff=1 Cap Cuff=2 Cap Cuff=3<br />

4.0 mm ISPA401P ISPA402P ISPA403P ISPC401 ISPC402 ISPC403<br />

5.5 mm ISPA551P ISPA552P ISPA553P ISPC551 ISPC552 ISPC553<br />

7.0 mm ISPA701P ISPA702P ISPA703P ISPC701 ISPC702 ISPC703<br />

Solid Abutment & Protect Cap<br />

PH<br />

Solid Abutment<br />

Solid Protect Cap<br />

Using: Solid Driver (MSD300)<br />

Height Abutment Protect Cap<br />

4.0 mm ISA400P ISPC450<br />

5.5 mm ISA550P ISPC600<br />

7.0 mm ISA700P ISPC750<br />

Solid shoulder Analog, Pin<br />

Solid shoulder Analog & Pin<br />

Bridge Material REF code<br />

Solid shoulder analog Plastic ISLA100<br />

Analog pin Titanium ISLA200<br />

<strong>ISG</strong> DENTAL GmbH<br />

<strong>Dental</strong>handel, Ordinationsbau & Beratung<br />

Tel.: +43/1/869 32 20 Fax: +43/1/869 32 30<br />

zentrale@isg-gmbh.at www.isg-gmbh.at<br />

Solid Analog<br />

Height REF code<br />

4.0 mm ISN400<br />

5.5 mm ISN550<br />

7.0 mm ISN700<br />

Snap Impression Cap<br />

REF-Code ISIC100<br />

Positioning Cylinder<br />

Height REF-Code<br />

7.0 mm IIPC100<br />

© 2010 <strong>ISG</strong> <strong>Dental</strong> GmbH - alle Rechte vorbehalten. Vorbehaltlich Druck- und Satzfehler.


ExFeel ® Internal | Abutments<br />

Octa Gold Abutment<br />

Non-Octa Octa<br />

Using: 1.2 Hex Hand driver<br />

(TCMHDL1200 or TCMHDS1200) or<br />

1.2 Hex Right angle driver (MDR120)<br />

Non-Octa Octa<br />

Plastic sleeve white Plastic sleeve red<br />

IOGN100T IOGO100T<br />

Octa Plastic Abutment<br />

Non-Octa Octa<br />

Abutment Screw<br />

Abutment Screw:<br />

Included IRCS200<br />

Using: 1.2 Hex Hand driver<br />

(TCMHDL1200 or TCMHDS1200) or<br />

1.2 Hex Right angle driver (MDR120)<br />

Non-Octa Octa<br />

Abutment Screw:<br />

Included IRCS200<br />

Plastic white Plastic red<br />

IOPN100T IOPH100T<br />

Using: 1.2 Hex Hand driver<br />

(TCMHDL1200 or TCMHDS1200) or<br />

1.2 Hex Right angle driver (MDR120)<br />

Angeled Abutment IAAS600<br />

Octa Gold Abutment/Healing Cap IRCS200<br />

Multi Post/Gold Abutment EXIMS100<br />

<strong>ISG</strong> DENTAL GmbH<br />

<strong>Dental</strong>handel, Ordinationsbau & Beratung<br />

Tel.: +43/1/869 32 20 Fax: +43/1/869 32 30<br />

zentrale@isg-gmbh.at www.isg-gmbh.at<br />

Octa Abutment & Healing Cap<br />

Octa Abutment:<br />

Abutment for multiple<br />

bridge teeth<br />

Using: Octa Driver (MOD300)<br />

REF Code IOA200<br />

Octa Healing Cap<br />

Using: 1.2 Hex Hand driver<br />

(TCMHDL1200 or TCMHDS1200) or<br />

1.2 Hex Right angle driver (MDR120)<br />

Octa Healing Cap Screw<br />

Profile diameter Ø5.5 mm 2.0 mm x 0.40 pitch<br />

IHC400T IAAS600<br />

Impression & Lab Analog<br />

Octa Impression Coping<br />

Pick-Up type<br />

15mm Guid pin:<br />

included RIOG150<br />

Octa Analog:<br />

analog for Octa Abutment<br />

Using: 1.2 Hex Hand driver<br />

(TCMHDL1200 or TCMHDS1200) or<br />

1.2 Hex Right angle driver (MDR120)<br />

Octa Impression Coping Guide Pin<br />

Profile diameter Ø5.5 mm RIOG150<br />

Octa Non-Octa Octa Analog<br />

RIOH100T RION100T IOA300<br />

© 2010 <strong>ISG</strong> <strong>Dental</strong> GmbH - alle Rechte vorbehalten. Vorbehaltlich Druck- und Satzfehler.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!