Rescue ®<br />

Internal<br />

<strong>exklusiv</strong> <strong>bei</strong> <strong>ISG</strong> <strong>Dental</strong> <strong>Gmbh</strong><br />

<strong>ISG</strong> DENTAL GmbH<br />

<strong>ISG</strong><br />

<strong>Dental</strong>handel,<br />

DENTAL GmbH<br />

Ordinationsbau & Beratung<br />

Tel.: +43/1/869 32 20 Fax: +43/1/869 32 30<br />

<strong>Dental</strong>handel, Ordinationsbau & Beratung<br />

Tel.: +43/1/869 32 20 Fax: +43/1/869 32 30<br />

zentrale@isg-gmbh.at www.isg-gmbh.at<br />

zentrale@isg-gmbh.at www.isg-gmbh.at


Inner hole<br />

Diameter:<br />

Ø 4.0<br />

L<br />

Fixure Length<br />

Super RBM Surface<br />

D2<br />

D1<br />

Rescue<br />

Super Wide & Short - The Most Effective<br />

Implant System for Molar Reconstruction<br />

® Internal<br />

Submerged Internal Trip Connection<br />

Unlike other wide diameter fixtures which have experienced severe bone loss, our<br />

specially engineered design with platform switching maintains crestal bone.<br />

Restoration of molar sites can be achieved with Rescue implants, despite minimal<br />

vertical height and inferior osseos tissue sites.<br />

Extraction sockets can be restored with Rescue fixtures.<br />

Design: The 0.8 degree pitched thread provides maximum contact for effective osseointegration.<br />

Because of the buttress thread design, it can withstand strong masticatory<br />

forces. The four cutting edges and guided bottom ensure maximum initial<br />

stability.<br />

Surface: Our Super RBM Surface Treatment produces a favorable surface topography<br />

that has been proven through extensive systematic testing. MegaGen‘s Super<br />

RBM Surface shortens loading time and provides favorable results in any bone quality.<br />

Feature: Internal Trip Connection - MegaGen‘s Trip anti-rotation structure will not deform<br />

until 420N of insertion torque, allowing for extremely stable initial fixation. The<br />

11° Internal Connection Wall, which is a proven concept of Morse Taper & Conical<br />

Seal, effectively allows for extremely high occlusal and lateral forces. Initial stability<br />

upon placement is provided.<br />

Surgery: Super wide fixtures can be placed with a two step drilling procedure consisting<br />

of a Trephine drill and a Pilot drill, (using the drill stop in the trephine drill). The<br />

Rescue surgical kit can be used for internal and external fixtures as an economical<br />

solution.<br />

Prosthetics: The Rescue Internal system provides various Internal Trip Connection<br />

Abutments (UCLA Gold, EZ Post, Milling abutment, Solid abutment system) that have<br />

Ø6.0, 8.0, 10.0mm wide healing abutments & Ø6.0, 7.0, 8.0mm profile abutment diameters.<br />

This conveniently provides aesthetic and functional prosthetic options.<br />

Packaging: Internal Fixture with Cover Screw<br />

Platform<br />

Diameter<br />

Thread<br />

Diameter<br />

SEM(X1000)<br />

M2.5mm<br />

Female Screw<br />

Tripod Grip<br />

Super - RBM Surface<br />

internal Angle 11°<br />

Trip Indicating Grooves<br />

D1 D2 L(mm)<br />

Ø6.0 Ø4.5 5.0<br />

Ø6.5 Ø5.0<br />

Ø7.0 Ø5.0<br />

Ø7.5 Ø5.5<br />

Ø8.0 Ø6.0<br />

6.0<br />

7.0<br />

8.5<br />

10.0<br />

11.5<br />

13.0


5<br />

Drill Extension Direction Indicator 1.2 Hand Driver Extension Plus<br />

Ø6.0<br />

Ø5.0<br />

MDE150 MDI5060<br />

Safety Trephine Stopper system<br />

10.0 mm<br />

8.0 mm<br />

6.0 mm<br />

4.0 mm<br />

2.0 m<br />

Marking<br />

Length<br />

1.2 Hex<br />

TCMHDL1200 or<br />

TCMHDS1200<br />

6.0 7.0 8.5 10.0<br />

MRTBS06 MRTBS08<br />

MRTBS07 MRTBS10<br />

<strong>ISG</strong> DENTAL GmbH<br />

<strong>Dental</strong>handel, Ordinationsbau & Beratung<br />

Tel.: +43/1/869 32 20 Fax: +43/1/869 32 30<br />

zentrale@isg-gmbh.at www.isg-gmbh.at<br />

MRE400S<br />

Step 1: Trephine Drilling with Stopper<br />

In order to create the osteotomy, follow drilling<br />

sequence according to fixture diameter.<br />

For safe trephine drilling, rotate drill in counter<br />

clockwise direction until saw part of trephine bur<br />

engages crest of bone. Then proceed drilling in<br />

clockwise direction.<br />

STEP 2: Pilot Drilling<br />

In accordance with drilling sequence, extended<br />

the osteotomy using the pilot drill.<br />

STEP 3: Tapping<br />

In dense bone situations, pre-tapping may be<br />

required prior to placement of fixture.<br />

STEP 4: Fixture Placement<br />

Use mount-free handpiece connector to place<br />

fixture. If necessary, complete placement by using<br />

the ratchet wrench. To easily verify trip direction<br />

in fixture, notch indicators are provided at the<br />

coronal portion of the implant.<br />

Ratchet<br />

Extensions<br />

[Ext/Int]<br />

© 2010 <strong>ISG</strong> <strong>Dental</strong> GmbH - alle Rechte vorbehalten. Vorbehaltlich Druck- und Satzfehler.


1<br />

2<br />

3<br />

For 6.0 & 6.5 Diameter Fixturesv For 7.0 & 7.5 Diameter Fixturesv For 8.0 Diameter Fixture<br />

Ø6.0<br />

MTPR600I<br />

Ø5.4<br />

MRPD540<br />

Ø6.0<br />

MTPH600I<br />

Inner Dia Ø4.0<br />

Outer Dia Ø5.0<br />

MRTB4010<br />

SG II Rescue Surgical Kit<br />

Ø6.5<br />

MTPR650I<br />

Ø5.9<br />

MRPD590<br />

Ø6.5<br />

MTPH650I<br />

Ø7.0<br />

MTPR700I<br />

Ø6.4<br />

MRPD640<br />

Ø7.0<br />

MTPH700I<br />

Inner Dia Ø5.0<br />

Outer Dia Ø6.0<br />

MRTB5010<br />

Ø7.5<br />

MTPR750I<br />

Ø6.9<br />

MRPD690<br />

Ø7.5<br />

MTPH750I<br />

4<br />

Ø8.0<br />

MTPR800I<br />

Ø7.4<br />

MRPD740<br />

Ø6.0 Ø6.5 Ø7.0 Ø7.5 Ø8.0<br />

RSWIR6005C<br />

RSWIR6006C<br />

RSWIR6007C<br />

RSWIR6008C<br />

RSWIR6010C<br />

RSWIR6011C<br />

RSWIR6013C<br />

1<br />

22<br />

33<br />

55<br />

RSWIR6505C<br />

RSWIR6506C<br />

RSWIR6507C<br />

RSWIR6508C<br />

RSWIR6510C<br />

RSWIR6511C<br />

RSWIR6513C<br />

RSWIR7005C<br />

RSWIR7006C<br />

RSWIR7007C<br />

RSWIR7008C<br />

RSWIR7010C<br />

RSWIR7011C<br />

RSWIR7013C<br />

MOW4 00 M RW040S<br />

55<br />

RSWIR7505C<br />

RSWIR7506C<br />

RSWIR7507C<br />

RSWIR7508C<br />

RSWIR7510C<br />

RSWIR7511C<br />

RSWIR7513C<br />

5<br />

44<br />

Ø8.0<br />

MTPH800I<br />

Hand Piece Connectors<br />

MRHC100<br />

Ratchet Extensions<br />

MRIR100S<br />

RSWIR8005C<br />

RSWIR8006C<br />

RSWIR8007C<br />

RSWIR8008C<br />

RSWIR8010C<br />

RSWIR8011C<br />

RSWIR8013C<br />

MRHC200<br />

MRIR100L<br />

Inner Dia Ø6.0<br />

Outer Dia Ø7.0<br />

MRTB6010<br />

Marking<br />

Length<br />

13.0 mm<br />

11.5 mm<br />

10.0 mm<br />

8.5 mm<br />

7.0 mm<br />

6.0 mm<br />

5.0 mm<br />

Marking<br />

Length<br />

13.0 mm<br />

11.5 mm<br />

10.0 mm<br />

8.5 mm<br />

7.0 mm<br />

6.0 mm<br />

5.0 mm<br />

5.0 mm<br />

6.0 mm<br />

7.0 mm<br />

8.5 mm<br />

10.0 mm<br />

11.5 mm<br />

13.0 mm<br />

© 2010 <strong>ISG</strong> <strong>Dental</strong> GmbH - alle Rechte vorbehalten. Vorbehaltlich Druck- und Satzfehler.


Rescue ® Internal | Abutments<br />

Cover Screw<br />

Connect cover screw on platform after<br />

placing fixture to protect platform and inner<br />

screw hole until the second surgery.<br />

Using: 1.2 Hex Hand driver<br />

(TCMHDL1200 or TCMHDS1200) or<br />

1.2 Hex Right angle driver (MDR120)<br />

Interface Diameter REF-Code<br />

Ø4.0 mm ARSIC100<br />

Healing Abutment<br />

Profile Diameter<br />

Height<br />

Component to get proper emergence profile after<br />

removing cover screw during the second surgery.<br />

Using: 1.2 Hex Hand driver<br />

(TCMHDL1200 or TCMHDS1200) or<br />

1.2 Hex Right angle driver (MDR120)<br />

Ø6.0 mm Ø8.0 mm Ø10.0 mm<br />

2.0 mm ARSIH602 ARSIH802 ARSIH1002<br />

3.0 mm ARSIH603 ARSIH803 ARSIH1003<br />

4.0 mm ARSIH604 ARSIH804 ARSIH1004<br />

5.0 mm ARSIH605 ARSIH805 ARSIH1005<br />

Lab Analog<br />

Component to dublicate platform<br />

instead of fixture into working model<br />

to make prosthetics<br />

Profile Diameter REF Code<br />

Ø6.0 mm ARLA600<br />

<strong>ISG</strong> DENTAL GmbH<br />

<strong>Dental</strong>handel, Ordinationsbau & Beratung<br />

Tel.: +43/1/869 32 20 Fax: +43/1/869 32 30<br />

zentrale@isg-gmbh.at www.isg-gmbh.at<br />

Impression Coping (Pick Up Type)<br />

Non-Trip Trip<br />

Impression Coping (Transfer Type)<br />

1-Piece Trip Type<br />

Impression coping with<br />

closed tray<br />

10 mm Trip Type Guide<br />

Pin: Included ARIG300<br />

Impression coping<br />

with open Tray<br />

15mm Guide Pin:<br />

Included ARIG100<br />

Using: 1.2 Hex Hand driver<br />

(TCMHDL1200 or TCMHDS1200) or<br />

1.2 Hex Right angle driver (MDR120)<br />

Non-Trip Trip Type<br />

ARII400T ARII200T<br />

Using: 1.2 Hex Hand driver<br />

(TCMHDL1200 or TCMHDS1200) or<br />

1.2 Hex Right angle driver (MDR120)<br />

1-Piece Trip Type<br />

ARII100 ARII300T<br />

Temporary Abutment<br />

Used in cases of path, esthetic<br />

and space adjustment<br />

Using: 1.2 Hex Hand driver<br />

(TCMHDL1200 or TCMHDS1200) or<br />

1.2 Hex Right angle driver (MDR120)<br />

Ø6.0 mm Non-Trip Trip<br />

Non-Trip Trip<br />

ARIT100T ARIT200T<br />

© 2010 <strong>ISG</strong> <strong>Dental</strong> GmbH - alle Rechte vorbehalten. Vorbehaltlich Druck- und Satzfehler.


Rescue ® Internal | Abutments<br />

Solid & Post Level Analog<br />

Ø6.0 Ø7.0 Ø8.0 Ø6.0 Ø7.0 Ø8.0<br />

Component to dublicate solid post instead of fixture and<br />

solid abutment into working model to make prosthetics<br />

Ø6.0 mm Ø7.0 mm Ø8.0 mm<br />

6.0 mm ARIPL660 ARIPL760 ARIPL860<br />

8.0 mm ARIPL680 ARIPL780 ARIPL880<br />

Guide Pin<br />

Guide Pin & Waxing Pin<br />

6.0 mm<br />

Using:<br />

1.2 Hex Hand driver<br />

(TCMHDL1200 or TCMHDS1200) or<br />

1.2 Hex Right angle driver (MDR120)<br />

10 mm ARIG300<br />

15 mm ARIG100<br />

20 mm ARIG200<br />

Abutment Screw<br />

Using: 1.2 Hex Hand driver<br />

(TCMHDL1200 or TCMHDS1200) or<br />

1.2 Hex Right angle driver (MDR120)<br />

Short: Fixture 5 mm ARAS250<br />

Long: Fixture 6-13 mm ARAS250L<br />

8.0 mm<br />

10mm 15mm 20mm<br />

1.2 Hex<br />

Abutment Screw for Temporary,<br />

EZ Post, Angeled<br />

<strong>ISG</strong> DENTAL GmbH<br />

<strong>Dental</strong>handel, Ordinationsbau & Beratung<br />

Tel.: +43/1/869 32 20 Fax: +43/1/869 32 30<br />

zentrale@isg-gmbh.at www.isg-gmbh.at<br />

Height<br />

Solid Abutment Non-Trip<br />

Ø6.0<br />

Profile Diameter<br />

6.0 mm<br />

Ø7.0 Ø8.0 Ø6.0 Ø7.0 Ø8.0<br />

Height<br />

Cuff<br />

Used for general cement<br />

type prosthetics<br />

Using: 1.2 Hex Hand driver<br />

(TCMHDL1200 or TCMHDS1200) or<br />

1.2 Hex Right angle driver (MDR120)<br />

Hand Driver (MTRD100S/MTRD100L)<br />

Ø6.0 mm 4.0 mm 6.0 mm 8.0 mm<br />

8.0 mm<br />

1 mm ARSIS641 ARSIS601 ARSIS681<br />

2 mm ARSIS642 ARSIS602 ARSIS682<br />

3 mm ARSIS643 ARSIS603 ARSIS683<br />

4 mm ARSIS644 ARSIS604 ARSIS684<br />

Ø7.0 mm 4.0 mm 6.0 mm 8.0 mm<br />

1 mm ARSIS741 ARSIS701 ARSIS781<br />

2 mm ARSIS742 ARSIS702 ARSIS782<br />

3 mm ARSIS743 ARSIS703 ARSIS783<br />

4 mm ARSIS744 ARSIS704 ARSIS784<br />

Ø8.0 mm 4.0 mm 6.0 mm 8.0 mm<br />

1 mm ARSIS841 ARSIS801 ARSIS881<br />

2 mm ARSIS842 ARSIS802 ARSIS882<br />

3 mm ARSIS843 ARSIS803 ARSIS883<br />

4 mm ARSIS844 ARSIS804 ARSIS884<br />

© 2010 <strong>ISG</strong> <strong>Dental</strong> GmbH - alle Rechte vorbehalten. Vorbehaltlich Druck- und Satzfehler.


Rescue ® Internal | Abutments<br />

EZ Post Trip-Type<br />

Ø6.0 Ø7.0 Ø8.0<br />

1.2 Hex<br />

Profile Diameter<br />

Using: 1.2 Hex Hand driver<br />

(TCMHDL1200 or TCMHDS1200) or<br />

1.2 Hex Right angle driver (MDR120)<br />

Height<br />

Cuff<br />

Used for general cement type prosthetics<br />

Abutment Screw (Fixture 5, 6mm):Included ARAS250<br />

Abutment Screw (Fixture 7-13mm): Included ARAS250L<br />

Ø6.0 mm 4.0 mm 6.0 mm 8.0 mm<br />

1 mm ARSIP641 ARSIP601T ARSIP681T<br />

2 mm ARSIP642 ARSIP602T ARSIP682T<br />

3 mm ARSIP643 ARSIP603T ARSIP683T<br />

4 mm ARSIP644 ARSIP604T ARSIP684T<br />

Ø7.0 mm 4.0 mm 6.0 mm 8.0 mm<br />

1 mm ARSIP741 ARSIP701T ARSIP781T<br />

2 mm ARSIP742 ARSIP702T ARSIP782T<br />

3 mm ARSIP743 ARSIP703T ARSIP783T<br />

4 mm ARSIP744 ARSIP704T ARSIP784T<br />

Ø8.0 mm 4.0 mm 6.0 mm 8.0 mm<br />

1 mm ARSIP841 ARSIP801T ARSIP881T<br />

2 mm ARSIP842 ARSIP802T ARSIP882T<br />

3 mm ARSIP843 ARSIP803T ARSIP883T<br />

4 mm ARSIP844 ARSIP804T ARSIP884T<br />

<strong>ISG</strong> DENTAL GmbH<br />

<strong>Dental</strong>handel, Ordinationsbau & Beratung<br />

Tel.: +43/1/869 32 20 Fax: +43/1/869 32 30<br />

zentrale@isg-gmbh.at www.isg-gmbh.at<br />

EZ Post Non-Trip<br />

Ø6.0 Ø7.0 Ø8.0<br />

1.2 Hex<br />

Profile Diameter<br />

Used for general cement type prosthetics<br />

Abutment Screw (Fixture 5, 6mm): Included ARAS250<br />

Abutment Screw (Fixture 7-13mm): Included ARAS250L<br />

Using: 1.2 Hex Hand driver<br />

(TCMHDL1200 or TCMHDS1200) or<br />

1.2 Hex Right angle driver (MDR120)<br />

Ø6.0 mm 4.0 mm 6.0 mm 8.0 mm<br />

1 mm ARSIPN641 ARSIPN601T ARSIPN681T<br />

2 mm ARSIPN642 ARSIPN602T ARSIPN682T<br />

3 mm ARSIPN643 ARSIPN603T ARSIPN683T<br />

4 mm ARSIPN644 ARSIPN604T ARSIPN684T<br />

Ø7.0 mm 4.0 mm 6.0 mm 8.0 mm<br />

1 mm ARSIPN741 ARSIPN701T ARSIPN781T<br />

2 mm ARSIPN742 ARSIPN702T ARSIPN782T<br />

3 mm ARSIPN743 ARSIPN703T ARSIPN783T<br />

4 mm ARSIPN744 ARSIPN704T ARSIPN784T<br />

Ø8.0 mm 4.0 mm 6.0 mm 8.0 mm<br />

Height<br />

Cuff<br />

1 mm ARSIPN841 ARSIPN801T ARSIPN881T<br />

2 mm ARSIPN842 ARSIPN802T ARSIPN882T<br />

3 mm ARSIPN843 ARSIPN803T ARSIPN883T<br />

4 mm ARSIPN844 ARSIPN804T ARSIPN884T<br />

© 2010 <strong>ISG</strong> <strong>Dental</strong> GmbH - alle Rechte vorbehalten. Vorbehaltlich Druck- und Satzfehler.


Rescue ® Internal | Abutments<br />

Comfort Cap<br />

Height<br />

Ø6.0 Ø7.0 Ø8.0<br />

To protect solid abutment and reduce discomfort<br />

Ø6.0 mm Color REF Code<br />

4 mm Yellow ARIC640<br />

6 mm White ARIC660<br />

8 mm Pink ARIC680<br />

Ø7.0 mm Color REF Code<br />

4 mm Yellow ARIC740<br />

6 mm White ARIC760<br />

8 mm Pink ARIC780<br />

Ø8.0 mm Color REF Code<br />

4 mm Yellow ARIC840<br />

6 mm White ARIC860<br />

8 mm Pink ARIC880<br />

<strong>ISG</strong> DENTAL GmbH<br />

<strong>Dental</strong>handel, Ordinationsbau & Beratung<br />

Tel.: +43/1/869 32 20 Fax: +43/1/869 32 30<br />

zentrale@isg-gmbh.at www.isg-gmbh.at<br />

Snap Impression Coping<br />

Height<br />

Impression coping in case of using solid abutment<br />

and EZ Post<br />

Color coded in accordance with abutment height<br />

Ø6.0 mm Color REF Code<br />

4 mm Yellow ARIIC640<br />

6 mm White ARIIC660<br />

8 mm Pink ARIIC680<br />

Ø7.0 mm Color REF Code<br />

4 mm Yellow ARIIC740<br />

6 mm White ARIIC760<br />

8 mm Pink ARIIC780<br />

Ø8.0 mm Color REF Code<br />

4 mm Yellow ARIIC840<br />

6 mm White ARIIC860<br />

8 mm Blue ARIIC880<br />

Gold Abutment<br />

Trip<br />

Ø6.0 Ø7.0 Ø8.0<br />

Non-Trip<br />

Used for general screw type<br />

prosthetics.<br />

Using: 1.2 Hex Hand driver<br />

(TCMHDL1200 or TCMHDS1200) or<br />

1.2 Hex Right angle driver (MDR120)<br />

Ø6.0 mm Trip Non-Trip<br />

ARGA200T ARGA100T<br />

© 2010 <strong>ISG</strong> <strong>Dental</strong> GmbH - alle Rechte vorbehalten. Vorbehaltlich Druck- und Satzfehler.