COMcheck
Report
powered by cove
GreenEdge
Sample Project
Green Edge
John Smith
Principal Architect
johnsmith@greenedge.com
09/16/2024
Table of
Contents
03 COMCheck Envelope Report Process
04 Envelope Report Overview
05 Key Project Inputs & Assumptions
2
COMcheck
Envelope Report
Process
cove is pleased to present the assumptions and methodologies that
guided our analysis for the Project Name COMcheck Envelope
submission. This document outlines the foundational elements and
specific details utilized in our evaluation, ensuring transparency and
clarity in our approach.
Through a meticulous review of the provided drawings and
relevant documentation, we have tailored our analysis to reflect
the project's unique characteristics and compliance requirements
accurately. The following sections detail the assumptions made
throughout the compliance process.
We advise the stamping professional or architect of record to
review the requirements and inputs with the engineers for this
project to ensure that they sign off on the compliance choices and
indicate the locations on their plans.
*This report contains sample data, your report will have all the inputs and analysis specifically catering to your project.
3
Envelope
Report
Overview
Solara Habitat
Project Information Assumptions Deliverables
The following information was used for
developing the COMCheck report.
• Provided Revit Model & Intake Form
details were used to establish code,
compliance method, and project
details.
• Performance Alternative was
established for Compliance Method.
• Building Characteristics and Features
were selected for more accurate
results.
The following information outlines key
assumptions made when reviewing the
envelope:
• Ceilings: Used the model to create
ceiling assemblies and insulation R-
Values.
• Ext. Wall: Leveraged the model to
define wall area, types, and cardinal
directions along with the drawings
to inform wall assemblies, stud
spacing, and insulation R-Values.
• Window: Established window types
with the model provided and used the
drawings for U-Factor and SHGC
values.
• Door: Defined door types and
materials with the model and drawings
• Garage Door: Defined garage door
area with the
model, polystyrene insulated door
cores were assumed.
• Floor: For concrete slab-on-grade,
typical perimeter insulation values and
depth were assumed.
• COMcheck-Web Compliance Report
• DASarchitects_Envelope_Report_coveto
ol.cxl
• PDF file: DASarchitects - covetool
Report Process
The .cxl file contains all data specifically used
to evaluate this building project. To be able
to verify the inputs in this report, the .cxl file
will need to be uploaded to the COMCheck
website/desktop app.
To upload, please open COMCheck, log in
with the user desired, and go to “My
Projects”. Once you click on that section,
you will have the option to choose the .cxl
file from your computer location and upload
it to the software. It is important to press
“save” after the upload, if not the project will
not be added to your projects list, and the
upload process will need to be repeated the
next time the file is open.
Once the file is open, all the inputs can be
reviewed & edited by section. In case of any
modification, we recommend pressing save
after you are done.
To check compliance, click the compliance
button at the top to run again, to verify it is
up to date. If everything is adequate and
correct, save the changes to the .cxl file and
generate the report. Under the user &
password section, the report button will
allow you to generate reports along with the
compliance checklist.
*This report contains sample data, your report will have all the inputs and analysis specifically catering to your project.
4
Key Project Inputs
& Assumptions
Envelope Inputs
Ceiling - Cont. R-Value (h ft² F / BTU) 41
Roof – Proposed U-Factor 0.029
Unheated Slab on Grade Perimeter (ft) 1049
Unheated Slab on Grade - Cont. R-Value (h ft² F / BTU) 10
Unheated Slab on Grade - Proposed U-Factor 0.540
Wood-Framed Wall - Cavity R-Value (h ft² F / BTU) 21
Wood-Framed Wall - Proposed U-Factor 0.090
Metal Frame Window – Glazing Proposed U-Factor 0.4
Metal Frame Window – Glazing SHGC 0.24
Glass Door – Proposed U-Factor 0.340
Glass Door – SHGC 0.22
Insulated Metal Garage Door – Proposed U-Factor 0.23
Insulated Metal Solid Door – Proposed U-Factor 0.380
Project Details
Location 100 Peachtree St Floor 5, Atlanta, GA 30303
Energy Code IECC 2021
Climate Zone
3a
Project Type
New Construction
Compliance Method
Performance Alternative
Total Area 4309 ft 2
Building Type
Residential
# of Buildings 1
*This report contains sample data, your report will have all the inputs and analysis specifically catering to your project.