01.07.2025 Views

FS Cables The Little Red Book - Issue 12

The Little Red Book cabling guide is a handy A5 size contains technical information, application data and images for over 8,000 products, many with CPR compliant options. A must have resource for those involved in buying or specifying electric cables. Sections include AV, Data, Bus, Coaxial, Signal & Control, Power, Fire & Security, Telephone, Rubber & Crane, Marine, Fibre, and High Temperature as well as a guide to custom-manufactured cables. There’s also a handy look up table to find alternative to Belden cables from one of the largest ranges in Europe.

The Little Red Book cabling guide is a handy A5 size contains technical information, application data and images for over 8,000 products, many with CPR compliant options.
A must have resource for those involved in buying or specifying electric cables.

Sections include AV, Data, Bus, Coaxial, Signal & Control, Power, Fire & Security, Telephone, Rubber & Crane, Marine, Fibre, and High Temperature as well as a guide to custom-manufactured cables. There’s also a handy look up table to find alternative to Belden cables from one of the largest ranges in Europe.

SHOW MORE
SHOW LESS

Transform your PDFs into Flipbooks and boost your revenue!

Leverage SEO-optimized Flipbooks, powerful backlinks, and multimedia content to professionally showcase your products and significantly increase your reach.

FS Cables the little red book

Issue 12

Issue 12

the little

red book

flexible and specialist cables


How to Order:

By phone

01727 840 841

By email

sales@fscables.com

Online

www.fscables.com

By fax

01727 840 842

Our hours are

Mon - Fri 8am to 6pm

Delivery Options:

Next working-day delivery

is standard to most of the mainland UK,

free for orders over £100.

Same-day deliveries

distance and time permitting. Call for a

quote giving us the delivery postcode.

No cut-off time

for orders – if we can ship it, we will.

Collections

between 8am & 6pm. Pre-order if

possible to save you time.

Payment Options:

Apply for a credit account

Please ask your sales contact or visit the website for an

account application form

By payment card

We accept most major credit, debit and purchasing cards

How to find us

FS Cables are based on Alban Park in St. Albans near J3 of

the A1(M) and J22 of M25. If using a Sat-Nav, please use the

postcode AL4 0JX and bear right of the car dealership. The

warehouse is the large silver building on your right with the

separate office building to the left. www.fscables.com/map

Express Delivery Options for

Parcels and Small Drums:

Pre 10.30am / Pre 12pm and next

working-day service available

Pre 12pm and next working-day

service available

Next working-day service

available

2-3 day service – please

check at time of order

5-10 day service – please

check at time of order

www.fscables.com | sales@fscables.com


Welcome

The little red book is divided into colour coded

sections to make it easier for you to find the

products you need. You’ll find an intro at the

beginning of each section telling you a bit about

applications and the group of products that follow.

There’s information on over 8,000 products in this

book but if you can’t find what you’re looking for

do give one of our technical sales team a call or try

the intuitive search tool on the website.

You have a huge choice of where you spend your

money - and we never take anything for granted.

We’ll do our absolute best to meet your needs but

you’re the best judge of that.

Your feedback matters, drop us a line at

feedback@fscables.com or look out for the feefo

review link in your email order confirmation. Each

and every one of your comments is reviewed at

the next management meeting.

Data 7

LAN & Structured Wiring 25

Home Automation & Audio 33

BMS 45

Fire & Security 55

Fibre Optic 71

LSHF 85

Signal & Control 99

Coaxial 127

Telephone 141

Power 147

Rubber & Crane 155

High Temperature 163

Bus 173

Marine & Offshore 181

Special Manufacture 205

Tables 208

Index 214

Standards Cross Reference Chart 216

Tel: 01727 840 841


2

Service & Support

Worldwide Deliveries

If you need cables delivered outside the UK,

our dedicated export team is on hand. Offering

a fast and comprehensive service, supplying

you with export packaging, cables cut to

length, essential paperwork and certificates.

Dispatch by courier, air, sea and road to be

with you where and when you need it.

We are authorised by the Chamber of

Commerce to produce all the export

documentation such as Certificates of Origin

and EUR1’s, in house, providing you with a fast

and efficient service.

From Marine, Oil & Gas to specialised solutions

for energy, process control, transport systems

and much more, we deliver where and when

you need it.

Export

Contact Details:

By phone

+44 1727 849 841

By email

sales@fscglobal.com

Web

www.fscglobal.com

Same Day Dispatch

There is no cut off time for orders, if we can ship

your order we will. For really urgent orders we

can courier goods same-day, time permitting.

Modern Warehousing

Facility

Over 67,000sq ft. of modern office and

warehouse space featuring large, secure loading

and unloading facilities.

Commitment to Stock

Over 3,500 product lines are held in stock for next

working-day delivery.

Cut to Length

We cut to length on the majority of product lines

meaning you only buy what you need – reducing

wastage and saving you money.

Custom Manufacture

If you need a cable manufactured to your own

specification or standard – talk to us. This can

range from a printed or coloured jacket, right

through to composite cables containing multiple

elements of your choice.

Armouring and

Over-Sheathing

Over-sheathing or steel wire armouring (SWA) to

an existing cable with short lead times and for

quantities as low as 100m.

Order Call-Off

Place an order and ‘call it off’ as required from

our warehouse for ‘just in time’ deliveries. This

both fixes your costs and guarantees supply.

www.fscables.com | sales@fscables.com


Tel: 01727 840 841

3


4

CPR for Cables

CPR for cables

Most cables designed for permanent installation within domestic, residential and commercial buildings are now

subject to the Construction Products Regulation (CPR), covered by BS EN 50575. This became a legal requirement in

July 2017 so it’s important you understand how to stay compliant.

BS EN 50575 enables designers and installers to consider the contribution that cables make to the spread of fire.

Cables are a particular concern as they run between rooms and floors, above ceilings and are often made from

flammable materials. They can also be a source of ignition if badly installed, damaged or faulty.

The classes

The regulation classifies products into one of seven Euroclasses, but in most instances only five will apply to cables.

You are likely to see a lot of cables to Class Eca and some to Class Fca.

Fire performance: high level of flammability under simple test and burns over 425mm.

Tests: BS EN 60332-1-2 (basic vertical flame test by factory or lab).

FSC Comment: Cables classified to Class Fca may have high levels of flammability due to the

materials they are made of or their designs. For example, cables with a PE sheath that are

primarily intended for outside use, such as telephone or duct grade cable, could be tested

and classified to Class Fca.

Fire performance: limited fire spread under test and burns less than 425mm.

Tests: BS EN 60332-1-2 (by an authorised test house, known as a Notified Body - NB).

FSC Comment: Although this is the least expensive test by an approved independent test

body (NB), it still costs many hundreds of pounds. It is likely that many cables sold in small

volumes will only be tested to this class for commercial reasons. Note that this test does not

measure heat release, toxic fumes or smoke.

Classes Dca, Cca and B2ca also apply to cables. The following classes also have additional tests to measure heat

generated smoke release and can be further tested for smoke density, acidity of gas given off and burning droplets

falling from the cable.

Fire performance: moderate fire spread and potentially high levels of heat generated.

Tests: BS EN 60332-1-2 and BS EN 50399, including smoke generation.

Additional tests: Smoke test, optional flaming droplets and acidity tests.

FSC Comment: This is an expensive test, costing thousands of pounds, but does not have

regular re-test or factory audit costs.

Fire performance: reduced flame spread, limited fire growth/heat release.

Tests: BS EN 60332-1-2 and BS EN 50399, including smoke generation.

Additional tests: Smoke test, optional flaming droplets and acidity tests.

FSC Comment: More rigorous test and higher cost than Class Dca but with the additional

cost of regular, independent factory inspections, audits and periodic retesting. This is widely

accepted across Europe as the ‘go to’ standard, but be aware that many cables in their

current form may not meet Class Cca without costly redesign.

Fire performance: low flame spread, minimal fire growth & heat release.

Tests: BS EN 60332-1-2 and BS EN 50399, including smoke generation.

Additional tests: Smoke test, optional flaming droplets and acidity tests.

FSC Comment: Similar to Class Cca with lower acceptable heat release rate and burn

measurement. Regular factory audits and re-testing add to the cost. In practice, this is likely

to be the highest CPR class cables will meet.

It is unlikely that any commercial cables will be available to Class B1ca or Aca, simply due to

the materials they are made of and lack of demand.

www.fscables.com | sales@fscables.com


CPR for Cables

5

Who’s responsible?

In the UK it is up to the designer, specifier or installer to satisfy themselves that the products

chosen are appropriate for the application and meet any contractual requirements. It is

important to note that at the moment, CPR-classified products can be used within the UK,

whatever their Euroclass - providing that they are contractually acceptable.

When specifying cable in the UK, take care to assess the risk of fire within a building and

the potential ease of evacuation. Airports, hospitals, prisons, tunnels and high rise buildings

all offer their own unique challenges and should be assessed individually.

Which class?

In some parts of Europe, the national regulatory body is defining which Euroclass should be used in a specific

building or application; the UK has not taken this approach. The publication of the 18th Edition IET Wiring

Regulations July 2018 does not specify Euroclasses for specific applications, however some supplementary standards

such as BS 6701:2016+A1:2017 do specify Euroclasses. Specifiers and installers need to ensure the cables they

select are appropriate for the fire risk in the building or application and any contractual terms. The publication of BS

6701:2016+A1:2017 gives specifiers, consultants and installers a set of guidelines for telecommunications cables

and could be used to form the basis of a commercial contract, although this is supplementary to the IET Wiring

Regulations.

CPR does not outlaw the use of cables that emit excessive amounts of toxic fumes and smoke in the event of a

fire. It is down to the specifier to select suitable product, such as Low Smoke Halogen Free (LSHF) versions. Circuit

integrity cables, such as fire alarm cable (i.e. FP200), are not covered by CPR - this is likely to be some years away.

Stay compliant

Declaration of performance

Cables manufactured after July 2017 intended for permanent installation within a domestic, residential or

commercial building, or any other civil structure, should have a Declaration of Performance (DoP) available.

This document shows critical information such as:

Product type

Manufacturer’s name

Class met

By law, manufacturers or anyone importing cables from

outside the EU need to keep records of CPR compliant

cables sold and be able to provide DoP documentation for

up to 10 years after it was first sold. If purchasing FSC or

Tru brand CPR compliant cable, you can easily download

your CPR documentation straight to your mobile, tablet or

desktop through our CPR downloads tool.

Support

If you need support relating to CPR cabling talk to one

of our technical sales team on 01727 840 841 or to

download the full CPR guide visit

www.fscables.com/cpr-downloads

This information is correct at time of printing, Summer 2019,

for the latest information visit www.fscables.com/cpr

Tel: 01727 840 841


6

Belden Page Finder

Belden No.

Page

1048AH 22

1152A 23

1215A 22

1348AHDA 179

1502RHDA 50

1505A 23

1617A 23

1694A 23

3076FHA 174, 175

3077FHA 174

3078FHA 174

3079AHDA 175

3082AHDA 176

3083A 176

3084AHDA 176

3085A 176

3092AHDA 23, 178

3102A 177

3105AH 178

3106AH 178

3107AH 178

3108AH 178

3109AH 178

3119A 177

5304FE 51, 69

7701HD 53, 177

7702HD 53, 177

7703HD 53, 177

7704HD 53, 177

8102L 18

8103L 18

8104L 18

8105 18

8106HL 18

8107 18

8108H 18

8110 18

8112 18

8115 18

8118 18

8125 18

8132H 63

8133H 63

8162HL 19

8163HL 19

8164H 19

8166 19

8167H 19

8168 19

8170 19

8175 19

8178 19

8185 19

8205HL 8, 52

8312 DS

8325 DS

Belden No.

Page

8345 DS

8355 DS

8442HL 8

8444H 8

8451HL 9

8471HDAL 8,52,53,69,177

8473HL 8, 52

8719HL 9

8720HL 9

8723HDAL 13, 63, 66, 67

8728HL 13

8760HDL 9, 66

8761HDL 9

8762HDL 9

8769 14

8770HL 10

8771HL 10

8772HL 10

8773 14

8774H 14

8775 14

8776 14

8777HDAL 14,63,66,67,178

8778HL 14

9156H 8

9182HL 23

9207H 23

9248 DS

9272H 23

9363 22

9365 22

9368HL 20

9402HL 20

9418HL 11

9463H 23

9501HDL 12, 66

9502HDL 12, 66

9503HDL 12, 66

9504HDL 12, 66

9505HL 12

9506HDL 12, 66

9507H 12

9508HL 12

9509 12

9510HL 12

9515H 12

9519HL 12

9525HL 12

9533L 11

9534HL 11

9535L 11

9536HL 11

9537 11

9538HL 11

9539 11

9540HL 11

Belden No.

Page

9541HL 11

9542 11

9543 11

9544 11

9545 11

9546 11

9550 12

9688H 22

9696 DS

9728H 15

9729HDAL 15, 66, 67

9730HL 15

9731H 15

9732 15

9733 15

9734 15

9735 15

9736 15

9737 15

9738 15

9740HL 8, 52

9744H 8

9750H

DS

9767 14

9768H 14

9769 14

9773H 20

9774H 20

9829H 21

9830 21

9831 21

9832 21

9833 21

9834 21

9835 21

9836 21

9837 21

9838 21

9839 21

9841HDAL 16, 66, 67

9842HDAL 16, 63, 66, 67

9843H 16

9844H 16

9860 23

9873HL 20

9874L 20

9875L 20

9876 20

9877 20

9879 20

9880 22

9901H 22

9907H 22

9913 DS

9925 17

9927 17

Belden No.

Key

H = Low Smoke Halogen Free

D = Duct Grade

A = Armoured

L = PVC/LSF

Details of cables listed as DS

are available on a separate

datasheet.

Page

9929 17

9931 17

9932 17

9933 17

9934 17

9935 17

9936 17

9937 17

9938 17

9939 21

9940 21

9941 21

9942 21

9943 21

9944 21

9945 21

9946 21

9947 21

9948 21

9949 21

9950 21

9990 DS

9991 DS

H123A02H 23

H124C02H 23

H124C01H 23

YM29560H 178

In line with the rest of the

industry our LSF cables are

PVC based and will emit some

poisonous gases when burnt.

If you need halogen free

cables please specify LSHF.

FSC stock a wide range of genuine Belden cables or cost effective alternatives with PVC, Low Smoke

Halogen Free and duct grade jackets. Armoured versions are also available from stock.

www.fscables.com | sales@fscables.com


7

Data

Introduction

When you need high-quality alternatives to Belden

or other American style data cables we probably

have the one you are looking for. Manufactured to

match the performance as closely as possible you

can be confident that only top quality materials

have been used.

Many types are also made in Low Smoke Halogen

Free (LSHF) versions and contain no PVC or other

halogen emitting materials. These are ideal for use

in public areas such as hospitals, airports, transport

systems, office blocks and shopping centres.

If you need greater protection we also stock duct

grade and Steel Wire Armoured (SWA) options in

the most popular types. The outer sheath is normally

a heavy weather resistant Black PE to give a great

low friction finish making installation easy over long

runs. Where cables are not stocked in duct or SWA

grades, standard product can be armoured or over

sheathed for quantities as low as 100m within days,

so you can get the cable you need quickly without

massive wastage.

The term LSF or Low Smoke and Fume is a non

specific, often misleading term when relating to

Data cable and is rarely found outside the British

market. In most cases, LSF is based on PVC. The

FSC range of LSF cables use PVC that emits reduced

levels of poisonous fumes but they should not

be used as a substitute for LSHF or LSZH cables.

It is best to regard LSF as little or no better than

standard PVC. Beware of anyone telling you

anything different!

Contents

Unscreened Pairs 08

Screened Single Pair 09

Screened Triples 10

Overall Screened Multicores 11 - 12

Individually Screened Two Pair 13

Individually Screened Multipairs 14 - 15

Overall Foil & Braid Screened Pairs 16 & 18

Overall Foil & Braid Screened Cores 17

Individual & Overall Screened

Multipairs

19

Individually Screened Multipairs 20

Overall Foil & Braid Screened Pairs

& Cores

Instrumentation, Process Control &

PLTC

21

22

Coaxial & Twin-Axial 23

Transducer & Load Cell 24

Tel: 01727 840 841

DATA


8

Unscreened Pairs

Unscreened Paired Data Cable

General purpose unscreened single and multipair cables with a small outer diameter, frequently used in audio, bus, data,

security and instrumentation applications.

These cables can also be supplied with PE sheaths for running in ducts or in SWA versions for direct burial.

Low Smoke Halogen Free (LSHF) versions are available where indicated with

replaced by those that do not emit halogens or toxic smoke.

the insulation and sheath materials are

1601PUYL

CONSTRUCTION - SINGLE PAIR

Tinned copper stranded conductor, PVC/LSF

insulation on standard cable, twisted into a pair,

PVC/LSF sheath.

TECHNICAL INFORMATION

Voltage

Rating:

Colour

Code:

22AWG -16AWG:

14AWG:

CE: 450/750V†

300V

600V

22AWG -18AWG: Black & red

16AWG -14AWG: Black & white

Part No.

Alt. to

Belden

No. of

Pairs

AWG

CSA

mm 2

Weight

kg/km

O/D

mm

Nominal

Capacitance

C/C pF/m

2201PUYL 8442 1 22(7) 0.35 23 4.3 99

2201PUYH LSHF 1 22(7) 0.35 23 4.3 99

2001PUYL 8205 1 20(7) 0.56 26 4.6 81

2001PUYH LSHF 1 20(7) 0.56 26 4.6 81

1801PUYL 9740 1 18(16) 0.79 37 5.6 84

1801PUYH LSHF 1 18(16) 0.79 37 5.6 84

1601PUYL 8471 1 16(19) 1.34 56 7.0 108

1601PUYH LSHF 1 16(19) 1.34 56 7.0 108

1601PUYH06 VIOLET 1 16(19) 1.34 56 7.0 108

1401PUYL 8473 1 14(42) 2.01 89 8.6 73

1401PUYH LSHF 1 14(42) 2.01 89 8.6 73

2204CUYH

CONSTRUCTION - TWO & THREE PAIR

Tinned copper stranded conductor, PVC/LSF

insulation, cores twisted into pairs, pairs laid

together, clear tape, PVC/LSF sheath.

TECHNICAL INFORMATION

Voltage

Rating:

22AWG -18AWG:

CE: 450/750V†

Colour Code: Chart 3 page 210

300V

Part No.

Alt. to

Belden

No. of

Pairs

AWG

CSA

mm 2

Weight

kg/km

O/D

mm

Nominal

Capacitance

C/C pF/m

2202PUYH 9744 NH 2 22(7) 0.35 39 5.9 84

1802PUYH 9156 NH 2 18(16) 0.79 71 8.4 84

CONSTRUCTION - MULTICORE

Tinned copper stranded conductor, PVC/LSF

insulation, cores laid up, clear tape, PVC/LSF

sheath.

TECHNICAL INFORMATION

Voltage

Rating:

300V

CE: 450/750V†

Colour Code: Chart 2 page 210

Part No.

Alt. to

Belden

No. of

Pairs

AWG

CSA

mm 2

Weight

kg/km

O/D

mm

Nominal

Capacitance

C/C pF/m

1602CUYH 6200UE 2 16(19) 1.34 36 4.5 120

1802CUYH 6300UE 2 18(7) 0.90 22 3.9 71

2204CUYH 8444 NH 4 22(7) 0.35 34 4.7 111

† Applies to CE marked FSC branded stock only

Low Smoke Halogen Free

CPR-Compliant Options Available

www.fscables.com | sales@fscables.com


Screened Single Pair

9

Single Pair Screened Data Cable

General purpose foil screened single pair cables with a small outer diameter, frequently used in audio, data and

instrumentation applications. Polyethylene insulation results in lower signal loss than standard PVC insulation.

These cables can also be supplied with PE sheaths for running in ducts or in SWA versions for direct burial.

Low Smoke Halogen Free (LSHF) versions are available where indicated with

replaced by those that do not emit halogens or toxic smoke.

the insulation and sheath materials are

CONSTRUCTION - SCREENED SINGLE PAIR

Tinned copper conductor, polyethylene insulation,

twisted pair, aluminium/polyester foil screen,

tinned copper drain wire, PVC/LSF sheath. On duct

grade cables an additional UV stable LDPE jacket

is put over the standard PVC/LSF cables to give a

high degree of weather resistance.

TECHNICAL INFORMATION

Voltage Rating: 22AWG -18AWG: 300V

16AWG -14AWG: 600V

CE: 450/750V†

Temperature Rating: +60°C

UL Style*: 2092

Colour Code:

Black & clear

1601POFPL

Part No.

Alt. to

Belden

No. of

Pairs

AWG

CSA

mm 2

Weight

kg/km

O/D

mm

Nominal Capacitance

pF/m

C/C C/S

2201POFPL 8761 1 22(7) 0.35 25 4.5 79 154

2201POFPH LSHF 1 22(7) 0.35 25 4.5 79 154

2201POFPH06 VIOLET 1 22(7) 0.35 25 4.5 79 154

2201POFPD DUCT 1 22(7) 0.35 27 6.2 79 154

2001POFPL 8762 1 20(7) 0.56 35 5.2 89 161

2001POFPH LSHF 1 20(7) 0.56 35 5.2 89 161

2001POFPD DUCT 1 20(7) 0.56 38 6.5 89 161

1801POFPL 8760 1 18(16) 0.79 45 5.6 79 144

1801POFPH LSHF 1 18(16) 0.79 45 5.6 79 144

1801POFPH06 VIOLET 1 18(16) 0.79 45 5.6 79 144

1801POFPD DUCT 1 18(16) 0.79 48 8.1 79 144

1601POFPL 8719 1 16(19) 1.34 84 7.9 75 144

1601POFPH LSHF 1 16(19) 1.34 84 7.9 75 144

1401POFPL 8720 1 14(19) 1.92 109 9.0 79 154

1401POFPH LSHF 1 14(19) 1.92 109 9.0 79 154

1801POFPD

CONSTRUCTION - MINIATURE 22AWG

Tinned copper conductors, polypropylene

insulation, twisted pair, aluminium/polyester foil

screen tinned copper drain wire, PVC/LSF sheath.

TECHNICAL INFORMATION

Voltage Rating:

Temperature Rating:

Nominal Impedance:

Colour Code:

300V

CE: 450/750V†

+60°C

45 Ohms

Black & red

Part No.

Alt. to

Belden

No. of

Pairs

AWG

CSA

mm 2

Weight

kg/km

O/D

mm

Nominal Capacitance

pF/m

2201POFRL 8451 1 22(7) 0.35 20 3.5 111 220

2201POFRH LSHF 1 22(7) 0.35 20 3.5 111 220

C/C

C/S

† Applies to CE marked FSC branded stock only

* UL style numbers are given for cross reference purposes only. Not all the cables on this page are tested to or approved

by UL. If you require UL approved versions please tell us when you first enquire.

Low Smoke Halogen Free

Duct Grade

CPR-Compliant Options Available

Tel: 01727 840 841

DATA


10

Screened Triples

Three Core Overall Screened Data Cable

For use as audio or instrumentation wiring. Aluminium foil screening offers great protection from interference of the

signal and sufficiently reduces radiation from the cable. The tinned copper drain wire is kept in contact with the foil by

using a clear polyester separator tape during manufacture.

Low Smoke Halogen Free (LSHF) versions are available where indicated with

those that do not emit halogens or toxic smoke.

the sheath materials are replaced by

1803COFPL

CONSTRUCTION - 22AWG, 20AWG & 18AWG

Tinned copper conductor, polyethylene insulation,

cores laid up, aluminium/polyester foil screen,

tinned copper drain wire, PVC/LSF sheath.

TECHNICAL INFORMATION

Voltage Rating:

Temperature Rating:

300V

CE: 450/750V†

+60°C

UL Style*: 2093

Colour Code:

Black, red & clear

Part No.

Alt. to

Belden

No. of

Pairs

AWG

CSA

mm 2

Weight

kg/km

O/D

mm

Nominal Capacitance

pF/m

2203COFPL 8771 3 22(7) 0.35 35 5.1 75 134

2203COFPH LSHF 3 22(7) 0.35 35 5.1 75 134

2003COFPL 8772 3 20(7) 0.56 42 5.5 89 167

2003COFPH LSHF 3 20(7) 0.56 42 5.5 89 167

1803COFPL 8770 3 18(16) 0.79 56 6.3 79 157

1803COFPH LSHF 3 18(16) 0.79 56 6.3 79 157

C/C

C/S

† Applies to CE marked FSC branded stock only

* UL style numbers are given for cross reference purposes only. Not all the cables on this page are tested to or approved

by UL. If you require UL approved versions please tell us when you first enquire.

Low Smoke Halogen Free

CPR-Compliant Options Available

www.fscables.com | sales@fscables.com


Overall Screened Multicores

11

Overall Screened Multicored Data Cable RS232 24AWG

Uses include RS232 applications including instrumentation and sound where balanced lines are not required.

Low Smoke Halogen Free (LSHF) versions are available where indicated with the insulation and sheath materials are

replaced by those that do not emit halogens or toxic smoke.

CONSTRUCTION - 24AWG

Tinned copper conductor 24(7) AWG, 0.22mm 2 , PVC/LSF insulation. Cores laid up, overall aluminium/polyester

foil screen, tinned copper drain wire (24AWG), PVC/LSF sheath.

TECHNICAL INFORMATION

Voltage Rating:

Temperature Rating:

Nominal Capacitance:

300V

CE: 450/750V†

+60°C

UL Style*: 2464

Up to 8 core: Core to core 108pF/m, Core to screen 213pF/m

Above 8 core: Core to core 98pF/m, Core to screen 180pF/m

Colour Code: Up to 10 core Chart 1 page 210

Above 10 core Chart 2 page 210

Part No. Alt. to Belden No. of Cores Weight kg/km O/D mm

2403COFYL 9533 3 26 4.1

2404COFYL 9534 4 33 4.7

2404COFYH LSHF 4 33 4.7

2405COFYL 9535 5 35 4.8

2406COFYL 9536 6 42 5.3

2406COFYH LSHF 6 42 5.3

2407COFY 9537 7 45 5.3

2408COFYL 9538 8 49 5.7

2408COFYH LSHF 8 49 5.7

2409COFY 9539 9 60 6.2

2410COFYL 9540 10 61 6.2

2410COFYH LSHF 10 61 6.2

2415COFYL 9541 15 83 7.2

2415COFYH LSHF 15 83 7.2

2420COFY 9542 20 104 8.0

2425COFY 9543 25 139 8.6

2430COFY 9544 30 152 9.7

2440COFY 9545 40 195 10.9

2450COFY 9546 50 238 12.5

CONSTRUCTION - 18AWG

Tinned copper conductor 18(19) AWG, 0.79mm², PVC/LSF insulation, colour chart 1, page 210. Cores laid up,

overall aluminium/polyester foil screen, tinned copper drain wire (20AWG), PVC/LSF sheath. On duct grade

cables an additional UV stable LDPE jacket is put over the standard PVC/LSF cables to give a high degree of

weather resistance.

2415COFYL

1804COFYL

Part No. Alt. to Belden No. of Cores Weight kg/km O/D mm

1804COFYL 9418 4 78 6.2

1804COFYH LSHF 4 78 6.2

1804COFYD DUCT 4 102 8.4

† Applies to CE marked FSC branded stock only

A full range of 22AWG cored cables is available from stock with LSHF and duct grade versions available to order.

* UL style numbers are given for cross reference purposes only. Not all the cables on this page are tested to or approved

by UL. If you require UL approved versions please tell us when you first enquire.

Low Smoke Halogen Free

Duct Grade

CPR-Compliant Options Available

Tel: 01727 840 841

DATA


12

Overall Screened Multipairs

Overall Screened Multipair Data Cable RS232 24AWG & 22AWG

Widely used for computers, Point Of Sale, control systems and RS232 applications. This is a general purpose overall

screened twisted paired cable.

Low Smoke Halogen Free (LSHF) versions are available where indicated with

replaced by those that do not emit halogens or toxic smoke.

the insulation and sheath materials are

2403POFYD

CONSTRUCTION - 24AWG

Tinned copper conductor 24(7) AWG,

0.22mm 2 , PVC/LSF insulation. Twisted

into pairs, overall aluminium/polyester foil

screen, tinned copper drain wire (24AWG),

PVC/LSF sheath. On duct grade cables an

additional UV stable LDPE jacket is put over

the standard PVC/LSF cables to give a high

degree of weather resistance.

TECHNICAL INFORMATION - 24AWG & 22AWG

Voltage Rating:

Temperature Rating:

300V

CE: 450/750V†

+60°C

Nominal Capacitance: 1 Pair: Core to core 131pF/m

Core to screen 243pF/m

24AWG: Core to core 98pF/m

Core to screen 164pF/m

22AWG: Core to core 114pF/m

Core to screen 206pF/m

UL Style*: 2464

Colour Code: Chart 3 page 210

2206POFY

Part No.

Alt. to

Belden

No. of

Pairs

Weight

kg/km

O/D

mm

2401POFYL 9501 1 21 3.9

2401POFYH LSHF 1 21 3.9

2401POFYD DUCT 1 44 6.4

2402POFYL 9502 2 32 5.6

2402POFYH LSHF 2 32 5.6

2402POFYD DUCT 2 60 7.9

2403POFYL 9503 3 49 5.9

2403POFYH LSHF 3 49 5.9

2403POFYD DUCT 3 66 8.3

2404POFYL 9504 4 54 6.7

2404POFYH LSHF 4 54 6.7

2404POFYD DUCT 4 72 9.2

2405POFYL 9505 5 66 7.4

2405POFYH LSHF 5 66 7.4

2406POFYL 9506 6 72 7.4

2406POFYH LSHF 6 72 7.4

Part No.

Alt. to

Belden

No. of

Pairs

Weight

kg/km

O/D

mm

2406POFYD DUCT 6 93 9.6

2407POFYL 9507 7 80 7.5

2407POFYH LSHF 7 80 7.5

2408POFYL 9508 8 97 8.3

2408POFYH LSHF 8 97 8.3

2409POFYL 9509 9 104 8.5

2410POFYL 9510 10 119 9.5

2410POFYH LSHF 10 119 9.5

2415POFYL 9515 15 160 10.6

2415POFYH LSHF 15 160 10.6

2419POFYL 9519 19 192 11.4

2419POFYH LSHF 19 192 11.4

2425POFYL 9525 25 243 12.8

2425POFYH LSHF 25 243 12.8

2450POFY 9550 50 460 18.0

CONSTRUCTION - 22AWG

Tinned copper conductor 22(7) AWG, 0.34mm², PVC/LSF insulation. Twisted into pairs, overall aluminium/

polyester foil screen, tinned copper drain wire (24AWG), PVC/LSF sheath.

Part No. AWG No. of Pairs Weight kg/km O/D mm

2202POFY 22 2 38 5.8

2203POFY 22 3 50 6.1

2204POFY 22 4 71 6.8

2205POFY 22 5 81 7.4

2206POFY 22 6 88 7.9

2209POFY 22 9 123 9.1

2211POFY 22 11 160 9.9

2215POFY 22 15 190 10.9

2219POFY 22 19 234 12.8

† Applies to CE marked FSC branded stock only

* UL style numbers are given for cross reference purposes only. Not all the cables on this page are tested to or approved

by UL. If you require UL approved versions please tell us when you first enquire.

Low Smoke Halogen Free Duct Grade

CPR-Compliant Options Available

www.fscables.com | sales@fscables.com


Individually Screened Two Pair

13

Individually Screened Two Pair Data Cable 22AWG

Used extensively in the security industry for CCTV applications including telemetry. Also suitable for computer and

instrumentation applications where it is important to provide a high level of screening from external sources, together

with low levels of cross talk between pairs.

Low Smoke Halogen Free (LSHF) versions are available where indicated with

those that do not emit halogens or toxic smoke.

the sheath materials are replaced by

CONSTRUCTION - INDIVIDUALLY SCREENED

Tinned copper conductor 22(7) AWG 0.35mm 2 ,

polypropylene insulation, twisted into pairs, each

pair aluminium/polyester foil screened, common

tinned copper drain wire (24AWG), PVC/LSF

sheath. The duct grade version has a black UV

stable polyethylene sheath over the standard PVC/

LSF cable to provide a high degree of weather

resistance, while the armoured version is protected

by heavy galvanised steel wires and an external

grade sheath.

TECHNICAL INFORMATION

Voltage Rating:

Temperature Rating:

Nominal Impedance:

Nominal Capacitance:

Colour Code:

300V

CE: 450/750V†

+60°C

45 Ohms

Core to core 115pF/m

Core to screen 203pF/m

Red/Black & Green/White

2202PIFRL

Part No. Alt. to Belden No. of Pairs AWG Weight kg/km O/D mm

2202PIFRL 8723 2 22(7) 32 4.2

2202PIFRW WHITE 2 22(7) 32 4.2

2202PIFRH LSHF 2 22(7) 32 4.2

2202PIFRH06 VIOLET 2 22(7) 32 4.2

2202PIFRHW WHITE 2 22(7) 32 4.2

2202PIFRD DUCT 2 22(7) 50 6.2

2202PIFRA SWA 2 22(7) 210 9.8

CONSTRUCTION - INDIVIDUALLY AND

OVERALL SCREENED

Tinned copper conductor 22(7) AWG 0.35mm²,

polypropylene insulation, twisted into pairs, each

pair individually screened with aluminium/polyester

foil and 24AWG tinned copper drain wire, overall

aluminium/ polyester foil and 24AWG tinned

copper drain wire, PVC/LSF sheath.

TECHNICAL INFORMATION

Voltage Rating:

Temperature Rating:

Nominal Impedance:

Nominal Capacitance:

300V

CE: 450/750V†

+60°C

45 Ohms

UL Style*: 2717

Colour Code:

Core to core 115pF/m

Core to screen 203pF/m

Red/Black & Green/White

2202PIFRA

Part No. Alt. to Belden No. of Pairs AWG Weight kg/km O/D mm

2202PTFRL 8728 2 22(7) 42 5.5

2202PTFRH LSHF 2 22(7) 42 5.5

† Applies to CE marked FSC branded stock only

* UL style numbers are given for cross reference purposes only. Not all the cables on this page are tested to or approved

by UL. If you require UL approved versions please tell us when you first enquire.

Low Smoke Halogen Free Duct Grade SWA

CPR-Compliant Options Available

Tel: 01727 840 841

DATA


14

Individually Screened Multipairs

Individually Screened Multipair Data Cable 22AWG

These cables are used extensively within security, computer and instrumentation applications. Many sizes are also used

within the audio field as snake cables where the individual screening of pairs reduces cross talk.

The 3 pair version is particularly popular within the security industry for CCTV and access control systems.

Low Smoke Halogen Free (LSHF) versions are available where indicated with

those that do not emit halogens or toxic smoke.

the sheath materials are replaced by

2203PIFRD

CONSTRUCTION - 22AWG

Tinned copper conductor 22(7) AWG, 0.35mm 2 ,

polypropylene insulated. Twisted into pairs, each

pair aluminium/polyester foil screened, tinned

copper drain wire (24AWG), PVC/LSF sheath.

The duct grade version has a black UV stable

polyethylene sheath over the standard PVC/

LSF cable to provide a high degree of weather

resistance, while the armoured version is protected

by heavy galvanised steel wires and an external

grade sheath.

TECHNICAL INFORMATION

Voltage Rating:

Temperature Rating:

Nominal Impedance:

Nominal Capacitance:

300V

CE: 450/750V†

+60°C

50 Ohms

UL Style*: 2919

Core to core 98pF/m

Core to screen 180pF/m

Colour Code: Chart 3 page 210

2206PIFRL

Part No. Alt. to Belden No. of Pairs AWG Weight kg/km O/D mm

2203PIFRL 8777 3 22(7) 70 6.9

2203PIFRH LSHF 3 22(7) 70 6.9

2203PIFRD DUCT 3 22(7) 96 8.6

2203PIFRA SWA 3 22(7) 330 13.2

2206PIFRL 8778 6 22(7) 123 9.2

2206PIFRH LSHF 6 22(7) 123 9.2

2209PIFR 8774 9 22(7) 177 10.6

2209PIFRH LSHF 9 22(7) 177 10.6

2211PIFR 8775 11 22(7) 201 11.8

2212PIFRL 9768 12 22(7) 226 11.8

2212PIFRH LSHF 12 22(7) 226 11.8

2215PIFR 8776 15 22(7) 290 13.9

2217PIFR 9769 17 22(7) 331 14.7

2219PIFR 8769 19 22(7) 348 15.3

2227PIFR 8773 27 22(7) 502 18.0

2237PIFR 9767 37 22(7) 739 20.3

† Applies to CE marked FSC branded stock only

* UL style numbers are given for cross reference purposes only. Not all the cables on this page are tested to or approved

by UL. If you require UL approved versions please tell us when you first enquire.

Low Smoke Halogen Free Duct Grade SWA CPR-Compliant Options Available

www.fscables.com | sales@fscables.com


Individually Screened Multipairs

15

Individually Screened Multipair Data Cable Low Capacitance RS422 24AWG

For RS422 connection and any other application requiring both low capacitance and excellent isolation between pairs.

Used for CAD/CAM and many other industrial applications with high data rates.

Low Smoke Halogen Free (LSHF) versions are available where indicated with

those that do not emit halogens or toxic smoke.

the sheath materials are replaced by

CONSTRUCTION - 24AWG

Tinned copper conductor 24(7) AWG 0.22mm 2 ,

foam polyolefin insulation. Twisted into pairs,

each pair aluminium/polyester foil screened,

tinned copper drain wire (24AWG), PVC/LSF

sheath. The duct grade version has a black UV

stable polyethylene sheath over the standard PVC/

LSF cable to provide a high degree of weather

resistance, while the armoured version is protected

by heavy galvanised steel wires and an external

grade sheath.

TECHNICAL INFORMATION

Voltage Rating:

Temperature Rating:

Nominal Impedance:

Nominal Capacitance:

300V

CE: 450/750V†

+60°C

100 Ohms

UL Style*: 2493

Core to core 41 pF/m

Core to screen 76 pF/m

Colour Code: Chart 3 page 210

2402PIFFD

Part No. Alt. to Belden No. of Pairs Weight kg/km O/D mm

2402PIFFL 9729 2 66 6.8

2402PIFFH LSHF 2 66 6.8

2402PIFFD DUCT 2 79 9.6

2402PIFFA SWA 2 178 12.5

2403PIFFL 9730 3 80 8.5

2403PIFFH LSHF 3 80 8.5

2404PIFFL 9728 4 97 9.2

2404PIFFH LSHF 4 97 9.2

2406PIFF 9731 6 137 10.7

2406PIFFH LSHF 6 137 10.7

2409PIFF 9732 9 203 12.4

2411PIFF 9733 11 226 14.6

2412PIFF 9734 12 242 14.6

2415PIFF 9735 15 300 16.3

2417PIFF 9736 17 326 17.1

2419PIFF 9737 19 348 17.1

2427PIFF 9738 27 557 20.3

2406PIFF

† Applies to CE marked FSC branded stock only

* UL style numbers are given for cross reference purposes only. Not all the cables on this page are tested to or approved

by UL. If you require UL approved versions please tell us when you first enquire.

Low Smoke Halogen Free Duct Grade SWA CPR-Compliant Options Available

Tel: 01727 840 841

DATA


16

Overall Foil & Braid Screened Pairs

Overall Foil & Braid Screened Paired Data Cable RS485 Low Capacitance 24AWG

Designed for RS485 data connections. This cable combines low capacitance insulation with one of the highest levels of

screening to provide high speed, interference free, data transmission.

Low Smoke Halogen Free (LSHF) versions are available where indicated with

those that do not emit halogens or toxic smoke.

the sheath materials are replaced by

2401POHPH

CONSTRUCTION - 24AWG

Tinned copper conductor 24(7) AWG 0.22mm 2 ,

polyethylene insulation. Twisted into pairs, overall

aluminium/polyester foil screened, tinned copper

drain wire (24AWG), overall tinned copper braid

(90%). PVC/LSF sheath. The duct grade version

has a black UV stable polyethylene sheath over the

standard PVC/LSF cable to provide a high degree

of weather resistance, while the armoured version

is protected by heavy galvanised steel wires and an

external grade sheath.

TECHNICAL INFORMATION

Voltage Rating:

Temperature Rating:

Nominal Impedance:

Nominal Capacitance:

300V

CE: 450/750V†

+60°C

120 Ohms

UL Style*: 2919

Core to core 42 pF/m

Core to screen 76 pF/m

Colour Code: Chart 5 page 210

Part No. Alt. to Belden No. of Pairs Weight kg/km O/D mm

2401POHPL 9841 1 64 5.9

2401POHPH LSHF 1 64 5.9

2401POHPH06 VIOLET 1 64 5.9

2401POHPD DUCT 1 92 8.7

2401POHPA SWA 1 192 12.0

2402POHPL 9842 2 95 8.7

2402POHPH LSHF 2 95 8.7

2402POHPD DUCT 2 118 11.5

2402POHPA SWA 2 251 15.3

2403POHP 9843 3 108 9.2

2403POHPH LSHF 3 108 9.2

2404POHP 9844 4 125 9.9

2404POHPH LSHF 4 125 9.9

2402POHPL

† Applies to CE marked FSC branded stock only

* UL style numbers are given for cross reference purposes only. Not all the cables on this page are tested to or approved

by UL. If you require UL approved versions please tell us when you first enquire.

Low Smoke Halogen Free Duct Grade SWA CPR-Compliant Options Available

www.fscables.com | sales@fscables.com


Overall Foil & Braid Screened Cores

17

Overall Foil & Braid Screened Cored Data Cable RS232 & RS423 24AWG

A range of high-performance cables for use over extended distances at high data rates for RS232 and RS423

applications. Also well suited to industrial measurement where low signal distortion is required. These cables are widely

used in CAD/CAM applications.

CONSTRUCTION - 24AWG

Tinned copper conductor 24(7) AWG, 0.22mm 2 ,

foam polyolefin insulation. Cores laid up, overall

aluminium/polyester foil screen, tinned copper

drain wire (24AWG), overall tinned copper braid

(65%). PVC/LSF sheath.

TECHNICAL INFORMATION

Voltage Rating:

Temperature Rating:

Nominal Capacitance:

300V

+60°C

UL Style*: 2919

Colour Code:

Core to core 40 pF/m

Core to screen 72 pF/m

Up to 10 core:

Chart 1 page 210

Above 10 core:

Chart 2 page 210

2405CODF

Part No. Alt. to Belden No. of Cores Weight kg/km O/D mm

2402CODF N/A 2 33 4.7

2403CODF 9925 3 38 5.5

2404CODF 9927 4 45 5.8

2405CODF 9929 5 51 6.3

2406CODF 9931 6 58 6.7

2407CODF 9932 7 62 6.8

2408CODFL 9933 8 68 7.1

2409CODF 9934 9 77 7.6

2410CODF 9935 10 83 7.8

2415CODF 9936 15 107 8.9

2425CODF 9937 25 165 11.3

2437CODF 9938 37 207 12.7

* UL style numbers are given for cross reference purposes only. Not all the cables on this page are tested to or approved

by UL. If you require UL approved versions please tell us when you first enquire.

Tel: 01727 840 841

DATA


18

Overall Foil & Braid Screened Pairs

Overall Foil & Braid Screened Paired Data Cable RS232 & RS422 24AWG

A range of high-performance cables for use over extended distances at high data rates for RS232 and RS422

applications. Also well suited to industrial measurement applications where low signal distortion is required.

Low Smoke Halogen Free (LSHF) versions are available where indicated with

those that do not emit halogens or toxic smoke.

the sheath materials are replaced by

2406PODFL

CONSTRUCTION - 24AWG

Tinned copper conductor 24(7) AWG, 0.22mm 2 ,

foam polyolefin insulation. Twisted into pairs,

overall aluminium/polyester foil screen, tinned

copper drain wire (24AWG), overall tinned copper

braid (65%). PVC/LSF sheath.

TECHNICAL INFORMATION

Voltage Rating:

Temperature Rating:

Nominal Impedance:

Nominal Capacitance:

300V

CE: 450/750V†

+60°C

100 Ohms

UL Style*: 2919

Core to core 41 pF/m

Core to screen 72 pF/m

Colour Code: Chart 5 page 210

Part No. Alt. to Belden No. of Pairs Weight kg/km O/D mm

2402PODFL 8102 2 61 6.9

2402PODFH LSHF 2 61 6.9

2403PODFL 8103 3 71 7.2

2404PODFL 8104 4 80 7.7

2405PODF 8105 5 89 7.9

2406PODFL 8106 6 104 8.6

2406PODFH LSHF 6 104 8.6

2407PODF 8107 7 106 8.6

2408PODF 8108 8 118 9.3

2408PODFH LSHF 8 118 9.3

2410PODF 8110 10 150 10.9

2412PODF 8112 12.5+ 165 11.8

2415PODF 8115 15 196 12.6

2418PODF 8118 18 235 13.6

2419PODF N/A 19 248 13.6

2425PODF 8125 25 297 16.1

† Applies to CE marked FSC branded stock only

+ Twelve pairs plus one conductor.

* UL style numbers are given for cross reference purposes only. Not all the cables on this page are tested to or approved

by UL. If you require UL approved versions please tell us when you first enquire.

Low Smoke Halogen Free

CPR-Compliant Options Available

www.fscables.com | sales@fscables.com


Individual & Overall Screened Multipairs

19

Individual & Overall Screened Multipair Data Cable RS422 Low Capacitance

24AWG

Designed for RS422 data connections, this cable combines low capacitance insulation with very high levels of screening

to provide high speed, interference free, data transmission.

Low Smoke Halogen Free (LSHF) versions are available where indicated with

those that do not emit halogens or toxic smoke.

the sheath materials are replaced by

CONSTRUCTION - 24AWG

Tinned copper conductor 24(7) AWG 0.22mm 2 ,

foam polyolefin insulation. Twisted into pairs, each

pair individually aluminium/polyester foil screened

with an overall aluminium/polyester foil screen,

tinned copper drain wire (24AWG), overall tinned

copper braid (65%). PVC/LSF sheath.

TECHNICAL INFORMATION

Voltage Rating:

Temperature Rating:

Nominal Impedance:

Nominal Capacitance:

300V

CE: 450/750V†

+60°C

100 Ohms

UL Style*: 2493

Core to core 41 pF/m

Core to screen 72 pF/m

Colour Code: Chart 3 page 210

2402PTMFH

Part No. Alt. to Belden No. of Pairs Weight kg/km O/D mm

2402PTMFL 8162 2 92 8.7

2402PTMFH LSHF 2 92 8.7

2403PTMFL 8163 3 104 9.1

2403PTMFH LSHF 3 104 9.1

2404PTMFL 8164 4 121 9.9

2404PTMFH LSHF 4 121 9.9

2406PTMF 8166 6 150 11.3

2407PTMF 8167 7 158 11.3

2407PTMFH LSHF 7 158 11.3

2408PTMF 8168 8 177 12.0

2410PTMF 8170 10 245 15.0

2415PTMF 8175 15 325 17.0

2418PTMF 8178 18 354 17.5

2425PTMF 8185 25 522 21.0

† Applies to CE marked FSC branded stock only

* UL style numbers are given for cross reference purposes only. Not all the cables on this page are tested to or approved

by UL. If you require UL approved versions please tell us when you first enquire.

Low Smoke Halogen Free

CPR-Compliant Options Available

Tel: 01727 840 841

DATA


20

Individually Screened Multipairs

Individually Screened Multipair Data Cable 20AWG & 18AWG

Widely used in monitoring, computer, instrumentation and audio applications where the individually screened pairs

reduce cross talk. Reduced losses are achieved through the use of 20AWG or 18AWG conductors making this cable ideal

for long runs.

Low Smoke Halogen Free (LSHF) versions are available where indicated with

those that do not emit halogens or toxic smoke.

the sheath materials are replaced by

2009PIFPL

CONSTRUCTION - 20AWG

2 Pair - Tinned copper conductor 20(7)AWG,

0.56mm 2 , PVC/LSF insulated. Twisted into pairs,

each pair aluminium/polyester foil screened, tinned

copper drain wire (22AWG). PVC/LSF sheath.

Multipair - Tinned copper conductor 20(7)AWG,

0.56mm 2 , polypropylene insulated. Twisted into

pairs, each pair aluminium/polyester foil screened,

tinned copper drain wire (22AWG), PVC/LSF

sheath.

TECHNICAL INFORMATION

Voltage Rating:

Temperature Rating:

Nominal Impedance:

300V

CE: 450/750V†

+60°C

45 Ohms+

UL Style*: 2pair: 2464

Above 2pair: 2919

Colour Code:

2pair: Red/Black &

Green/White

Above 2pair: Chart 3 page 210

1802PIFYL

Part No.

Alt. to

Belden

No. of

Pairs

Weight

kg/km

O/D

mm

Nominal Capacitance

pF/m

C/C

C/S

2002PIFYL 9402 2 76 7.6 180 312

2002PIFYH LSHF 2 76 7.6 180 312

2003PIFPL 9873 3 104 8.7 98 180

2003PIFPH LSHF 3 104 8.7 98 180

2006PIFPL 9874 6 182 11.3 98 180

2009PIFPL 9875 9 270 14.1 98 180

2011PIFP 9876 11 302 15.2 98 180

2012PIFP 9877 12 322 15.7 98 180

2015PIFP 9879 15 384 17.5 98 180

2015PIFPH LSHF 15 384 17.5 98 180

CONSTRUCTION - 18AWG

2 Pair - Tinned copper conductor 18(19)AWG,

0.96mm 2 , PVC insulated. Twisted into pairs, each

pair aluminium/polyester foil screened, tinned

copper drain wire (20AWG). PVC/LSF sheath.

Multipair - Tinned copper conductor 18(19)AWG,

0.96mm 2 , polypropylene insulated. Twisted into

pairs, each pair aluminium/polyester foil screened,

tinned copper drain wire (20AWG), PVC/LSF

sheath.

TECHNICAL INFORMATION

Voltage Rating:

Temperature Rating:

Nominal Impedance:

300V

CE: 450/750V†

+60°C

45 Ohms+

UL Style*: 2pair: 2464

Above 2pair: 2919

Colour Code:

2pair: Red/Black

Above 2pair: Chart 3 page 210

Part No.

Alt. to

Belden

No. of

Pairs

Weight

kg/km

O/D

mm

Nominal Capacitance

pF/m

C/C

C/S

1802PIFYL 9368 2 103 9.6 187 335

1802PIFYH LSHF 2 103 9.6 187 335

1803PIFPL 9773 3 139 10.3 98 180

1803PIFPH LSHF 3 139 10.3 98 180

1806PIFPL 9774 6 259 13.2 98 180

1806PIFPH LSHF 6 259 13.2 98 180

† Applies to CE marked FSC branded stock only

* UL style numbers are given for cross reference purposes only. Not all the cables on this page are tested to or approved

by UL. If you require UL approved versions please tell us when you first enquire.

+ Impedence figure not applicable on two pair version

Low Smoke Halogen Free

CPR-Compliant Options Available

www.fscables.com | sales@fscables.com


Overall Foil & Braid Screened Pairs & Cores

21

Overall Foil & Braid Screened Data Cables RS232 & RS422 24AWG

A range of high-performance cables for use over extended distances at high data rates for RS232 applications. They are

also well suited to industrial measurement where low signal distortion is required.

The 24AWG foil & braid twisted paired cable runs over RS232 & RS422 protocols. Excellent dual screening enables this

cable to carry signals over long distances with minimum distortion.

Low Smoke Halogen Free (LSHF) versions are available where indicated with

that do not emit halogens or toxic smoke.

the sheath materials are replaced by those

CONSTRUCTION - 24AWG

Tinned copper conductor 24(7) AWG, 0.22mm 2 ,

polyethylene insulation. Twisted into pairs, overall

aluminium/polyester foil screen, tinned copper

drain wire (24AWG), overall tinned copper braid

(65%). PVC/LSF sheath.

TECHNICAL INFORMATION

Voltage Rating: 300V

Temperature Rating: +60°C

Nominal Impedance: 100 Ohms

Nominal Capacitance: Core to core 51 pF/m

Core to screen 90 pF/m

UL Style*: 2919

Colour Code: Chart 5 page 210

2402PODPL

Part No. Alt. to Belden No. of Pairs Weight kg/km O/D mm

2402PODPL 9829 2 61 7.4

2402PODPH LSHF 2 61 7.4

2403PODP 9830 3 70 7.7

2404PODP 9831 4 79 8.4

2405PODP 9832 5 84 8.6

2406PODP 9839 6 97 9.3

2407PODP 9833 7 103 9.4

2409PODP 9834 9 130 10.6

2410PODP 9835 10 140 11.5

2412PODP 9836 12 155 11.8

2418PODP 9837 18 225 14.4

2425PODP 9838 25 295 17.1

CONSTRUCTION - 22AWG

Tinned copper conductor 22(7) AWG,

0.35mm 2 , semi-rigid PVC insulation. Cores

laid up, overall aluminium/polyester foil

screen, tinned copper drain wire (24AWG),

overall tinned copper braid (65%). PVC/

LSF sheath

TECHNICAL INFORMATION

Voltage Rating:

300V

Temperature Rating: +60°C

Nominal Impedance: 100 Ohms

Nominal Capacitance:

Up to 5 core - Core to core 121 pF/m,

Core to screen 220 pF/m

Above 5 core - Core to core 115 pF/m

Core to screen 207 pF/m

UL Style*: 2464

Colour Code: Up to 10 core: Chart 1 page 210

Above 10 core: Chart 2 page 210

Part No. Alt. to Belden No. of Cores Weight kg/km O/D mm

2203CODY 9939 3 41 5.1

2204CODY 9940 4 48 5.5

2205CODY 9941 5 55 5.8

2206CODY 9942 6 63 6.2

2207CODY 9943 7 65 6.3

2208CODY 9944 8 74 6.6

2209CODY 9945 9 85 7.1

2210CODY 9946 10 94 7.6

2215CODY 9947 15 130 8.6

2225CODY 9948 25 189 10.4

2237CODY 9949 37 238 11.7

2250CODY 9950 50 348 14.1

* UL style numbers are given for cross reference purposes only. Not all the cables on this page are tested to or approved

by UL. If you require UL approved versions please tell us when you first enquire.

Low Smoke Halogen Free

CPR-Compliant Options Available

2209CODY

Tel: 01727 840 841

DATA


22

Instrumentation, Process Control & PLTC

Instrumentation, Process control & PLTC

Industrial process control and instrumentation cables suitable for use in a wide variety of industries from nuclear energy

generation to security and access control.

Low Smoke Halogen Free (LSHF) versions are available where indicated with

that do not emit halogens or toxic smoke.

the sheath materials are replaced by those

1802PTFNH

CONSTRUCTION - INDIVIDUALLY AND OVERALL SCREENED PAIRS

Plain copper conductor 18(7) AWG 0.88mm², LSHF insulation with a nylon skin.

Conductors twisted into pairs, black and white numbered pairs, each pair individually aluminium/polyester foil

screened with a 20(7) AWG tinned copper drain wire, pairs laid up with isolated screens. The overall screen is

aluminium/polyester foil screen with 20(7) AWG tinned copper drain wire. LSHF sheath.

Part No. Alt. to Belden No. of Pairs Weight kg/km O/D mm Voltage

1802PTFNH 1048A LSHF 2 115 9.9 600V

CONSTRUCTION - OVERALL SCREENED TRIPLE 22 & 18AWG

Tinned copper conductor, colour coded PVC insulation, black, red, white. Aluminium/polyester foil screen with

drain wire. PVC jacket.

Part No.

Alt. to

Belden

No. of

Cores

AWG

CSA

mm 2

Weight

kg/km

O/D mm

Voltage

2203COFY 9363 3 22(7) 0.35 39 5.3 300V

1803COFY 9365 3 18(16) 0.79 64 6.3 300V

IBM Cables

Part No.

Reference

Alt. to

Belden

IBM

Part No.

Description

O/D mm

2202PTDP IBM Type 1A 9688 4716748 2 x 2 x 22AWG 7.8 x 12

2404PUY IBM Type 3 - - 4 x 2 x 22AWG 4.7

2602PODF IBM Type 6 1215A 4716743 2 x 2 x 26(7)AWG 8.7

2601PODF IBM Type 7 - 4716746 1 x 2 x 26(7)AWG 6.3

Ethernet 10BASE5

Part No.

Alt. to

Belden

Description

Stranding

AWG

Capacitance pF/m

C/C

O/D mm

1201AXDD 9880 Trunk 12(1) 85 10.3

2004PTMFH 9901 LSHF Grey AUI Drop 4 x 2 x 20(7) 55 10.7

Ethernet 10BASE2

Part No.

Alt. to

Belden

Description

Stranding

AWG

Capacitance pF/m

C/C

O/D mm

2001AXD 9907 Thinnet 20(19) 86 4.6

2001AXDH LSHF Thinnet 20(19) 86 4.6

Low Smoke Halogen Free

www.fscables.com | sales@fscables.com


Coaxial & Twin-Axial

23

Coaxial & Twin-Axial Cables

A wide selection of coaxial cables, specifically designed for digital signal transmissions are listed. This market is changing

rapidly so if the cables you need are not listed please call us. You will also see two coaxes with London Underground

(LU) approval which are LSHF sheathed and designed to work in tunnels and high risk public areas. These are normally

available from stock.

Low Smoke Halogen Free (LSHF) versions are available where indicated with

that do not emit halogens or toxic smoke.

the sheath materials are replaced by those

Coaxial Cable

Part No.

Alt. to

Belden

AWG

Description

Sheath

Material

Weight

390006P 1152A 18(1) RG6 Type Quad Shield Plenum FEP 69 7.0

390059C08 1505A 20(1) RG59 Foil & Braid PVC 64 6.0

390011QAS 1617A 14(1) RG11 Quad Shield PVC 90 10.4

390006 1694A 18(1) RG6 Type Foil & TCWB PVC 62 7.0

390006Q 3092A 18(1) RG6 Quad Shield PVC 50 7.6

390006QH 3092A 18(1) RG6 Quad Shield LSHF 50 7.6

390H123A02 H123A02 22(1) H123 A02 LSHF 29 4.3

390H124HLU H124C02 1mm H124 C02 London Underground LSHF 53 7.0

390H124HTLU H124C01 1mm H124 C01 London Underground LSHF 100 8.8

O/D

mm

200278BPH

Twin-Axial

Twin-Axial cables were originally developed for I/O switching & process control applications. Now

widely used in commercial applications such as building management systems. Most types are also

stocked in LSHF versions as well as PVC.

If the Twin-Axial you are looking for is not shown please call us.

Part No.

Alt. to

Belden

AWG

O/D mm

Cap. pF/m

C/C

Imp. Ohms

Colour

220215FFL 9182 22(19) 9.0 29 150 Black

220215FFH LSHF 22(19) 9.0 29 150 Black

200278BP 9272 20(7) 6.2 65 78 Blue

200278BPH LSHF 20(7) 6.2 65 78 Blue

200278DP 9463 20(7) 6.2 65 78 Blue

200278DPH LSHF 20(7) 6.2 65 78 Blue

200210DP 9207 20(7) 8.4 51 100 Black

200210DPH LSHF 20(7) 8.4 51 100 Black

160212DP 9860 16(1) 11.2 36 124 Black

Low Smoke Halogen Free

CPR-Compliant Options Available

Tel: 01727 840 841

DATA


24

Transducer & Load Cell

Transducer & Load Cell Cables

Developed for accurate signal transmission in physically demanding conditions the FSC range of transducer and load

cell cables cover all the popular types. The ultra tough polyurethane jacket provides excellent protection against both

water and mechanical damage. To guard against the effects of nearby power cables or other sources of electromagnetic

radiation a choice of either a foil screen with drain wire or a high density tinned copper wire braid is offered.

9950020408

CONSTRUCTION - FOIL SCREENED

Tinned or plain copper conductor, colour coded PE

or PVC insulation, polyester tape, tinned copper

drain wire, inward facing aluminium/polyester

tape, tough polyurethane gloss jacket.

TECHNICAL INFORMATION

Voltage Rating:

Temperature Rating:

Max Conductor Resistance:

0.09mm 2 (28AWG):

0.22mm 2 (24AWG):

0.34mm 2 (22AWG):

300V

-30ºC to +80ºC

232 Ohms per km

92 Ohms per km

57 Ohms per km

Part No.

Cores x

mm 2

Weight

kg/km

O/D mm

Insulation

Type

Screen

Type

Colour

9950020408 4 x 0.22 29 4.6 PE Foil Orange

9950020608 6 x 0.22 36 6.2 PE Foil Orange

9950030408 4 x 0.34 35 6.0 PE Foil Orange

9950090405 4 x 0.09 21 4.0 PVC Foil Grey

9960050400

CONSTRUCTION - BRAID SCREENED

Tinned or plain copper conductor, colour coded

cold resistant PVC insulation, polyester tape,

high coverage tinned copper wire braid, tough

polyurethane gloss jacket.

TECHNICAL INFORMATION

Voltage Rating:

Temperature Rating:

Max Conductor Resistance:

0.22mm 2 (24AWG):

0.5mm 2 (20AWG):

300V

-30ºC to +80ºC

92 Ohms per km

39 Ohms per km

Part No.

Cores x

mm 2

Weight

kg/km

O/D mm

Insulation

Type

Screen

Type

Colour

9960020400 4 x 0.22 34 4.7 PVC Braid Black

9960050400 4 x 0.50 65 6.8 PVC Braid Black

Other sizes, colours and insulation types can be supplied for quantities as low as 2km. Cable can be printed with your

company name or message and phone number. See page 206 for details.

Full specifications sheets are available on the above giving electrical characteristics and colour codes.

www.fscables.com | sales@fscables.com


25

LAN - Structured Wiring

Introduction

The volumes of LAN or Structured wiring is set

to increase manyfold over the next few years.

Questions surround which category should be

specified or installed. The choice is expanding and

future proofing (at least for the next three years) is

important. Properly installed networks with good

quality products will carry significant amounts of

data at increasing speeds.

At FSC, the emphasis is on quality. Even some

poor quality cables with undersized conductors or

inferior insulations will usually carry data over very

short distances but where consistent performance

is needed over long runs or rapid transfer of large

data files it’s worth installing the best.

Contents

Cat 5E & Cat 5E UTP + Power 26

Cat 5E HDBaseT Recommended

& Cat 5E Bundled

27

Cat 6 & Cat 6 Bundled 28

Cat 6 HDBaseT Recommended 29

Cat 6A & Cat 6A HDBaseT

Recommended

30

Cat 7, Cat 7A and Cat 8 31

External Grade Structured Wiring 32

All FSC ethernet cables use pure copper conductors,

sized appropriately to ensure data transmission

at rates equal to or higher than the relevant TIA

standards. All test results are over the relevant

standard distance (normally 100m including 10m of

test leads) for example, be careful of suppliers that

specify Cat 6 performance up to 40m. It may not

work on longer runs due to lack of headroom.

The external duct grade and armoured versions use

full size conductors and are tested to the relevant

standards for maximum distance, all backed up by

datasheets and test certificates. Some types use the

latest water blocking tape technology.

In addition, much of the range has also been tested

and approved by the HDBaseT alliance ensuring

they are suitable for the ever growing requirement

of home automation including PoE (Power over

Ethernet).

Tel: 01727 840 841

STRUCTURED WIRING


26

Cat 5E & Cat 5E UTP + Power

Cat 5E Unscreened & Screened and Cat 5E UTP + Power

The FSC range of structured wiring cables are built for performance - we don’t skimp on conductor size or substitute

other materials - we figure that the cost of using a decent cable far outweighs the cost of ripping out an inferior one

and reinstalling something better. The range of Cat 5E cables are tested to a higher level than the industry standard of

100MHz over the full 100m test length. Many of the cables are also independently tested by HDBaseT for professional

video and home automation.

C5EHR

Cat 5E Unscreened 350MHz

TECHNICAL INFORMATION

Conductor Material: Solid Bare Copper

Conductor Size: 24AWG

Insulation:

Polyethylene

Screening:

Unscreened (U/UTP)

Pack Length: 500m Reel

Impedance:

Manufactured to:

Delay Skew:

Frequency:

100 Ohms

TIA 568-C.2

ISO/IEC 11801

<=45 ns/100m

Standard test 100MHz

Enhanced test 350MHz

Part No.

No. of Pairs

Sheath

Material

Colour

Weight

kg/km

O/D

mm

C5EHR 4 LSHF Grey 40 5.0

C5ERSHOTGUN 8 PVC Ivory 84 5.3 x 11.0

Cat 5E Screened 350MHz

C5EFHR

TECHNICAL INFORMATION

Conductor Material: Solid Bare Copper

Conductor Size: 24AWG

Insulation:

Polyethylene

Screening:

Overall Foil Screened (F/UTP)

Pack Length: 500m Reel

Impedance:

Manufactured to:

Delay Skew:

Frequency:

100 Ohms

TIA 568-C.2

ISO/IEC 11801

<=45 ns/100m

Standard test 100MHz

Enhanced test 350MHz

Part No.

No. of Pairs

Sheath

Material

Colour

Weight

kg/km

O/D

mm

C5EFR 4 PVC Grey 48 6.3

C5EFHR 4 LSHF Orange 48 6.3

Cat 5E UTP + Power

C5ER2D

TECHNICAL INFORMATION

CAT 5E UTP

Conductor Material: Solid Bare Copper

Conductor Size: 24AWG

Insulation:

Polyethylene

Screening:

Unscreened (U/UTP)

Pack Length: 500m Reel

Frequency:

100MHz

POWER

Conductor Material: Bare Copper

Conductor Size: 0.75mm², Class 5

Insulation:

PVC

Colour Code: Black & Red

Voltage Rating: 300/500V

Part No.

No. of

Pairs

No. of

Power Cores

Sheath

Material

Colour

Weight

kg/km

C5ER2 4 2 PVC Black 90 5.5 x 11.2

C5ER2D 4 2 PE Black 90 6.5 x 11.5

O/D

mm

Low Smoke Halogen Free Duct Grade CPR-Compliant Options Available

www.fscables.com | sales@fscables.com


Cat 5E HDBaseT Recommended & Cat 5E 25 Pair

27

Cat 5E HDBaseT Recommended and Cat 5E 25 Pair

Cat 5E HDBaseT cables have been tested and approved by the HDBaseT Alliance making it the ideal choice for high speed

data networks across a home or commercial building. The HDBaseT standard allows distribution of HD video, audio, 100BaseT

Ethernet, power and control across a single cable. Supplied on 305 metre pull boxes for easy handling and stacking.

Cat 5E HDBaseT Recommended

TECHNICAL INFORMATION

Conductor Material: Solid Bare Copper

Conductor Size: 24AWG

Insulation:

Polyethylene

Screening:

Unscreened (U/UTP)

Pack Length: 305m Box

Impedance:

Manufactured to:

Delay Skew:

Frequency:

100 Ohms

TIA 568-C.2

ISO/IEC 11801

<=45 ns/100m

Standard test 100MHz

Enhanced test 350MHz

C5T01

Part No.

No. of Pairs

Sheath

Material

Colour

Weight

kg/km

O/D

mm

C5T00 4 PVC Black 40 5.0

C5T01 4 PVC Blue 40 5.0

C5T03 4 PVC Red 40 5.0

C5T04 4 PVC White 40 5.0

C5T05 4 PVC Grey 40 5.0

C5T07 4 PVC Pink 40 5.0

C5T08 4 PVC Orange 40 5.0

C5T09 4 PVC Yellow 40 5.0

C5T10 4 PVC Green 40 5.0

C5TH00 4 LSHF Black 40 5.0

C5TH01 4 LSHF Blue 40 5.0

C5TH03 4 LSHF Red 40 5.0

C5TH04 4 LSHF White 40 5.0

C5TH05 4 LSHF Grey 40 5.0

C5TH06 4 LSHF Violet 40 5.0

C5TH07 4 LSHF Pink 40 5.0

C5TH08 4 LSHF Orange 40 5.0

C5TH09 4 LSHF Yellow 40 5.0

C5TH10 4 LSHF Green 40 5.0

C5TH03

Cat 5E Unscreened 25 Pair

Cable to support ADSL data rates are increasingly being flood wired in offices, airports, education and

commercial centres. Suitable for Gigabit Ethernet, Cat 5E 25 Pair data cables offer saving in installation

time and space. Stocked in Low Smoke Halogen Free (LSHF) or PE for duct grade or external installations.

C525H

TECHNICAL INFORMATION

Conductor Material: Solid Bare Copper

Conductor Size: 24AWG

Insulation:

Polyethylene

Screening:

Unscreened (U/UTP)

Pack Length: 500m Reel or Cut to Length

Impedance:

Manufactured to:

Delay Skew:

Frequency:

100 Ohms

TIA 568-C.2

ISO/IEC 11801

<=45 ns/100m

100MHz

Part No.

No. of Pairs

Sheath

Material

Colour

Weight

kg/km

O/D

mm

C525H 25 LSHF Grey 189 13.2

C525D 25 PE Black 278 13.5

Low Smoke Halogen Free Duct Grade CPR-Compliant Options Available

Tel: 01727 840 841

STRUCTURED WIRING


28

Cat 6 & Cat 6 Bundled

Cat 6 Unscreened & Screened and Cat 6 Bundled

Cat 6 cables are capable of carrying data at higher speeds with less crosstalk than the earlier Cat 5E cables. Ideal for

general data, telephony, security and BMS applications in commercial buildings. The FSC Cat 6 cables are tested to

500MHz and are fully compliant with the standard which specifies 250MHz at 100m.

C6RSHOTGUN

Cat 6 Unscreened 500MHz

TECHNICAL INFORMATION

Conductor Material: Solid Bare Copper

Impedance:

100 Ohms

Conductor Size:

Insulation:

Screening:

Pack Length:

23AWG

Polyethylene

Unscreened (U/UTP)

500m Reel

Manufactured to:

Delay Skew:

Frequency:

TIA 568-C.2

ISO/IEC 11801

<=45 ns/100m

Standard test 250MHz

Enhanced test 500MHz

Part No.

Cat 6 Screened 500MHz

No. of Pairs

Sheath

Material

Colour

Weight

kg/km

O/D

mm

C6HR08 4 LSHF Orange 46 6.6

C6RSHOTGUN 8 PVC Grey 94 6.2 x 13.4

C6HR09SHOTGUN 8 LSHF Yellow 94 6.2 x 13.4

TECHNICAL INFORMATION

C6FHR

Conductor Material:

Conductor Size:

Insulation:

Screening:

Pack Length:

Solid Bare Copper

23AWG

Polyethylene

Overall Foil Screened (F/UTP)

500m Reel

Impedance:

Manufactured to:

Delay Skew:

Frequency:

100 Ohms

TIA 568-C.2

ISO/IEC 11801

<=45 ns/100m

Standard test 250MHz

Enhanced test 500MHz

Part No.

Cat 6 Bundled

No. of Pairs

Sheath

Material

Colour

Weight

kg/km

O/D

mm

C6FR 4 PVC Grey 58 7.5

C6FHR 4 LSHF Orange 58 7.5

C6R6

Cat 6 bundled cables are available with 3, 4 and 6 Cat 6 UTP cables bundled into a single grey

overall jacket. These cables provide high speed data distribution and are suitable for Gigabit

Ethernet. They offer substantial savings in time & space compared to running individual cables and

also makes for a much easier installation.

TECHNICAL INFORMATION

Conductor Material:

Conductor Size:

Insulation:

Screening:

Pack Length:

Solid Bare Copper

23AWG

Polyethylene

Unscreened (U/UTP)

500m Reel, cut to length

Impedance:

Manufactured to:

Delay Skew:

Frequency:

100 Ohms

TIA 568-C.2

ISO/IEC 11801

<=45 ns/100m

Standard test 250MHz

Enhanced test 500MHz

Part No.

No. of Pairs

Sheath

Material

Colour

Weight

kg/km

O/D

mm

C6R3 12 PVC Grey 140 15.0

C6R4 16 PVC Grey 190 17.0

C6R6 24 PVC Grey 290 21.0

Low Smoke Halogen Free

CPR-Compliant Options Available

www.fscables.com | sales@fscables.com


Cat 6 HDBaseT Recommended

29

Cat 6 Unscreened & Screened HDBaseT Recommended Cable

Cat 6 HDBaseT cables have been tested and approved by the HDBaseT Alliance making it the ideal choice for high speed

data networks across a home or building. The HDBaseT standard allows distribution of HD video, audio, PoE, 100BaseT

Ethernet, power and control across a single cable. Supplied in sturdy 305 metre pull boxes for easy handling and

stacking. It’s also environmentally friendly and easy to recycle the packaging.

Cat 6 Unscreened HDBaseT Recommended

TECHNICAL INFORMATION

Conductor Material: Solid Bare Copper

Conductor Size: 23AWG

Insulation:

Polyethylene

Screening:

Unscreened (U/UTP)

Pack Length: 305m Box

Impedance:

Manufactured to:

Delay Skew:

Frequency:

100 Ohms

TIA 568-C.2

ISO/IEC 11801

<=45 ns/100m

Standard test 250MHz

Enhanced test 500MHz

C6T06

Part No.

No. of Pairs

Sheath

Material

Colour

Weight

kg/km

O/D

mm

C6T00 4 PVC Black 46 6.2

C6T01 4 PVC Blue 46 6.2

C6T03 4 PVC Red 46 6.2

C6T04 4 PVC White 46 6.2

C6T05 4 PVC Grey 46 6.2

C6T06 4 PVC Violet 46 6.2

C6T07 4 PVC Pink 46 6.2

C6T08 4 PVC Orange 46 6.2

C6T09 4 PVC Yellow 46 6.2

C6T10 4 PVC Green 46 6.2

C6TH00 4 LSHF Black 46 6.2

C6TH01 4 LSHF Blue 46 6.2

C6TH03 4 LSHF Red 46 6.2

C6TH04 4 LSHF White 46 6.2

C6TH06 4 LSHF Violet 46 6.2

C6TH07 4 LSHF Pink 46 6.2

C6TH08 4 LSHF Orange 46 6.2

C6TH09 4 LSHF Yellow 46 6.2

C6TH10 4 LSHF Green 46 6.2

C6TH10

Cat 6 Screened HDBaseT Recommended Cable

TECHNICAL INFORMATION

Conductor Material: Solid Bare Copper

Conductor Size: 23AWG

Insulation:

Polyethylene

Screening:

Overall Foil Screened (F/UTP)

Pack Length: 500m Reel, cut to length

Impedance:

Manufactured to:

Delay Skew:

Frequency:

100 Ohms

TIA 568-C.2

ISO/IEC 11801

<=45 ns/100m

Standard test 250MHz

Enhanced test 500MHz

C6TFH01

Part No.

No. of Pairs

Sheath

Material

Colour

Weight

kg/km

C6TFH01 4 LSHF Blue 58 7.5

O/D

mm

Low Smoke Halogen Free

CPR-Compliant Options Available

Tel: 01727 840 841

STRUCTURED WIRING


30

Cat 6A & Cat 6A HDBaseT Recommended

Cat 6A Unscreened & Screened and Cat 6A HDBaseT Recommended Cable

Cat 6A or Cat 6 Augmented to give it its full name is the next generation of data wiring. Available either unscreened (U/

UTP) or various levels of screening. Cat 6A is able to support 10 gigabits/sec over the full 100m at 500MHz and is great

for handling large files with minimum error rates.

C6GUUH

Cat 6A Unscreened 650MHz

TECHNICAL INFORMATION

Conductor Material: Solid Bare Copper

Impedance:

100 Ohms

Conductor Size:

Insulation:

Screening:

Pack Length:

23AWG

Polyethylene

Unscreened (U/UTP)

500m Reel

Manufactured to:

Delay Skew:

Frequency:

TIA 568-C.2

ISO/IEC 11801

<=45 ns/100m

Standard test 500MHz

Enhanced test 650MHz

Part No.

No. of Pairs

Sheath

Material

Colour

Weight

kg/km

C6GUUH 4 LSHF Blue 58 7.1

O/D

mm

Cat 6A Screened 650MHz

C6GFFH

TECHNICAL INFORMATION

Conductor Material:

Conductor Size:

Insulation:

Screening:

Pack Length:

Solid Bare Copper

23AWG

Foamed Polyethylene

Overall & Individually Foil

Screened (F/FTP)

500m Reel

Impedance:

Manufactured to:

Delay Skew:

Frequency:

100 Ohms

TIA 568-C.2

ISO/IEC 11801

<=45 ns/100m

Standard test 500MHz

Enhanced test 650MHz

Part No.

No. of Pairs

Sheath

Material

Colour

Weight

kg/km

C6GFFH 4 LSHF Blue 68 7.6

O/D

mm

Cat 6A Screened HDBaseT Recommended

TECHNICAL INFORMATION

Conductor Material:

Solid Bare Copper

Impedance:

100 Ohms

C6TGFUH04

Conductor Size:

Insulation:

Screening:

Pack Length:

23AWG

Polyethylene

Overall Foil Screened (F/UTP)

500m Reel

Manufactured to:

Delay Skew:

Frequency:

TIA 568-C.2

ISO/IEC 11801

<=45 ns/100m

Standard test 500MHz

Enhanced test 650MHz

Part No.

No. of Pairs

Sheath

Material

Colour

Weight

kg/km

O/D

mm

C6TGFUH01 4 LSHF Blue 62 7.5

C6TGFUH04 4 LSHF White 62 7.5

C6TGFUH06 4 LSHF Violet 62 7.5

Low Smoke Halogen Free

CPR-Compliant Options Available

www.fscables.com | sales@fscables.com


Cat 7, Cat 7A and Cat 8

31

Cat 7, Cat 7A and Cat 8

Cat 7, Cat 7A and Cat 8 are all shielded 4 twisted pair cables capable of carrying large quantities of data extremely

quickly. Speeds of 10 Gbps at 100MHz for Cat 7A are possible. The extensive shielding also reduces EMR creating a

healthier and safer environment.

Cat 7 Screened 600MHz

TECHNICAL INFORMATION

Conductor Material:

Conductor Size:

Insultation:

Screening:

Pack Length:

Solid Bare Copper

23AWG

Foamed Polyethylene

Individually Screened &

Overall Braid (S/FTP)

500m Reel

Impedance:

Manufactured to:

Delay Skew:

Frequency:

100 Ohms

TIA 568-C.2

ISO/IEC 11801, IEC 61156-5,

EN 50288-4

<=45 ns/100m

600MHz

C7HR08

Part No.

No. of Pairs

Sheath

Material

Colour

Weight

kg/km

O/D

mm

C7HR08 4 LSHF Orange 68 7.6

C7HR08SHOTGUN 8 LSHF Orange 110 7.2 x 15.4

Cat 7A Screened 1000MHz

TECHNICAL INFORMATION

Conductor Material: Solid Bare Copper

Conductor Size: 23AWG

Insulation:

Foamed Polyethylene

Screening:

Pack Length:

Part No.

Cat 8 2000MHz

Individually Screened &

Overall Braid (S/FTP)

500m Reel

No. of Pairs

Sheath

Material

Impedance:

Manufactured to:

Delay Skew:

Frequency:

Colour

100 Ohms

TIA 568-C.2

ISO/IEC 11801, IEC 61156-5,

EN 50288-4

<=45 ns/100m

1000MHz

Weight

kg/km

C7GHR08 4 LSHF Orange 68 7.6

The main application for Cat 8 cables is data centres and commercial or trading businesses where

vast amounts of data need to be transmitted. Cat 8 can carry two billion signals between 250 and

400 times faster than a Cat 5E cable which can carry 100 million signals. The test for Cat 8 is over 30

metres, so the cable is most likely to be used on small LAN’s in commercial premises. Cat 8 cables are

screened and the construction is all about achieving a known performance.

O/D

mm

C7HR08SHOTGUN

TECHNICAL INFORMATION

Conductor Material: Solid Bare Copper

Conductor Size: 23AWG

Insultation:

Foamed polyethylene

Screening:

Individually Screened &

Overall Braid (S/FTP)

Pack Length: 500m Reel

Impedance:

Manufactured to:

Delay Skew:

Frequency:

100 Ohms

TIA 568-C.2

ISO/IEC 11801

<=45 ns/100m

2000MHz

Cat 8.1 2000MHz

Part No.

No. of Pairs

Sheath

Material

Colour

Weight

kg/km

C8HR08 4 LSHF Orange 70 7.8

Cat 8.2 2000MHz

Part No.

No. of Pairs

Sheath

Material

Colour

Weight

kg/km

C8GHR05 4 LSHF Grey 74 8.8

Low Smoke Halogen Free

O/D

mm

O/D

mm

CPR-Compliant Options Available

Tel: 01727 840 841

STRUCTURED WIRING


32

External Grade Structured Wiring

External Grade Structured Wiring

For external installations, FSC offers an extensive range of UV resistant external grade cables from the simple commercial

grades, where the jacket has been replaced with a black PE, to our super tough double sheathed duct grade or SWA

(steel wire armoured) version, some with the revolutionary new water blocking tape, ideal for external applications.

C5EA

Cat 5E External Grade

TECHNICAL INFORMATION

Conductor Material: Solid Bare Copper

Conductor Size: 23AWG

Insulation:

Polyethylene

Screening:

Pack Length:

See Table

Bulk Reel (305m Box on

C5ECB only)

Impedance:

Manufactured to:

Delay Skew:

Frequency:

100 Ohms

TIA 568-C.2

ISO/IEC 11801

<=45 ns/100m

100MHz

Part No.

Cat 6 External Grade

Type

No. of

Pairs

Screening

Sheath

Material

Colour

Weight

kg/km

O/D

mm

C5EC Weatherproof 4 U/UTP PE Black 40 5.1

C5ECB Weatherproof 4 U/UTP PE Black 40 5.1

C5ED Duct Grade 4 U/UTP PE Black 67 7.8

C5EFD Duct Grade 4 F/UTP PE Black 68 8.6

C5EFD08 Duct Grade 4 F/UTP PE Orange 68 8.6

C525D Duct Grade 25 U/UTP PE Black 278 13.5

C5EA SWA 4 U/UTP PE Black 239 14.0

C5EFA SWA 4 F/UTP PE Black 275 14.8

C525A SWA 25 U/UTP PE Black 598 21.6

TECHNICAL INFORMATION

Conductor Material: Solid Bare Copper

Conductor Size: 23AWG

Insulation:

Polyethylene

Impedance:

Manufactured to:

100 Ohms

TIA 568-C.2

ISO/IEC 11801

C6FD

Screening:

Pack Length:

See Table

1000m Reel, cut to length

Delay Skew:

Frequency:

<=45 ns/100m

250MHz

Part No.

Cat 6A External Grade

Type

No. of

Pairs

Screening

Sheath

Material

Colour

Weight

kg/km

O/D

mm

C6C Weatherproof 4 U/UTP PE Black 46 6.2

C6FC Weatherproof 4 F/UTP PE Black 68 7.6

C6D Duct Grade 4 U/UTP PE Black 86 8.6

C6FD Duct Grade 4 F/UTP PE Black 105 10.0

C6A SWA 4 U/UTP PE Black 309 15.0

C6FA SWA 4 F/UTP PE Black 315 15.5

TECHNICAL INFORMATION

Conductor Material: Solid Bare Copper

Conductor Size: 23AWG

Insulation:

Foamed Polyethylene

Screening:

Pack Length:

Overall & Indivually Screened

(F/FTP)

1000m Reel, cut to length

Impedance:

Manufactured to:

Delay Skew:

Frequency:

100 Ohms

TIA 568-C.2

ISO/IEC 11801

<=45 ns/100m

500MHz

Part No.

Type

No. of

Pairs

Screening

Sheath

Material

Colour

Weight

kg/km

C6GFFHD Duct Grade 4 F/FTP PE Black 68 10.0

O/D

mm

Duct Grade

SWA

www.fscables.com | sales@fscables.com


33

Home Automation

& Audio

Introduction

Home Automation is one of the major growth

areas of the 21st century. With lifestyles changing

more rapidly than ever before, it is not just the

equipment we use to view or listen, it’s ‘our entire

surrounding’.

Home entertainment is no longer limited to

watching on a single screen in a single location,

increasingly users want to move from room to room

and even change the devices they use to consume

their entertainment without breaking continuity.

Every application involves cabling at some stage and

frequently people are moving away from relying

totally on Wi-Fi and wireless to hard wiring buildings

to meet future demands as well as today’s needs.

For this you need quality products. There is no

point installing cheap, substandard products when

performance is critical.

Contents

Trusound Speaker Cables 34 - 37

HD Media Composite Technical

Specifications

38

HD Media Composite Cables 39 - 41

FSTP & Line Level Audio Cables 42

Microphone & Star Quad Cables 43

Snake & DMX Cables 44

FSC’s range of home automation, audio and

speaker cables are built to last giving you the

confidence they will perform well into the future.

Designed for commercial and high-end residential

installations where quality matters.

Tel: 01727 840 841

HA & AUDIO


34

TruSound OFC Speaker Cable

TSS162

16awg, 14awg & 12awg OFC Speaker Cables

Developed from the American market, these cables use 16AWG, 14AWG or 12AWG oxygen free

copper conductors. Clearly identified by their distinctive colour and printing, they are widely used in

commercial and high-end residential installations. Also manufactured using halogen free materials

for both the jacket and core insulation, these versions are ideal for commercial installations

requiring LSHF cables.

The weatherproof versions feature a water blocking tape and a waterproof, UV resistant PE outer

jacket making them ideal for external applications.

TSS164C

Part No.

Cores x

AWG

Stranding

No. x mm

Weight

kg/km

O/D mm

Sheath

Material

Colour

TSS162 2 x 16 41 x 0.20 35 6.1 PVC Pink

TSS162W 2 x 16 41 x 0.20 35 6.1 PVC White

TSS162C 2 x 16 41 x 0.20 40 6.5 PE Black

TSS162H 2 x 16 41 x 0.20 35 6.1 LSHF Violet

TSS162H07 2 x 16 41 x 0.20 35 6.1 LSHF Pink

TSS162H08 2 x 16 41 x 0.20 35 6.1 LSHF Orange

TSS162HW 2 x 16 41 x 0.20 35 6.1 LSHF White

TSS164 4 x 16 41 x 0.20 54 7.0 PVC Pink

TSS164W 4 x 16 41 x 0.20 54 7.0 PVC White

TSS164C 4 x 16 41 x 0.20 61 7.4 PE Black

TSS164H 4 x 16 41 x 0.20 54 7.0 LSHF Violet

TSS164H07 4 x 16 41 x 0.20 54 7.0 LSHF Pink

TSS164H08 4 x 16 41 x 0.20 54 7.0 LSHF Orange

TSS164HW 4 x 16 41 x 0.20 54 7.0 LSHF White

TSS142 2 x 14 105 x 0.16 89 7.1 PVC Pink

TSS142H 2 x 14 105 x 0.16 89 7.1 LSHF Violet

TSS144 4 x 14 105 x 0.16 165 9.1 PVC Pink

TSS144H 4 x 14 105 x 0.16 165 9.1 LSHF Violet

TSS122 2 x 12 65 x 0.25 139 8.8 PVC Pink

TSS122H 2 x 12 65 x 0.25 139 8.8 LSHF Violet

TSS124 4 x 12 65 x 0.25 210 10.5 PVC Pink

TSS124H 4 x 12 65 x 0.25 210 10.5 LSHF Violet

Low Smoke Halogen Free

CPR-Compliant Options Available

www.fscables.com | sales@fscables.com


TruSound Multicore Speaker Cable

35

Multicore Speaker Cables

TSS02504

Designed for the professional, these multicore speaker cables are extremely flexible due to the high

rate of conductor twist and the insulation and jacket materials used. Ideal for winding on and off

drums when touring, they even remain flexible at low temperatures making rigging easier. They are

also great for large fixed installations where sound quality is important.

The range of conductor sizes enables long runs with very low power loss.

Part No. Cores x mm 2 Stranding No.

x mm

Weight

kg/km

O/D mm

Sheath

Material

Colour

TSS01502 2 x 1.5 30 x 0.25 75 7.0 PVC Black

TSS01502H 2 x 1.5 30 x 0.25 75 7.0 LSHF Black

TSS01504 4 x 1.5 30 x 0.25 120 8.0 PVC Black

TSS01504H 4 x 1.5 30 x 0.25 120 8.0 LSHF Black

TSS02502 2 x 2.5 50 x 0.25 90 8.0 PVC Black

TSS02502H 2 x 2.5 50 x 0.25 90 8.0 LSHF Black

TSS02504 4 x 2.5 50 x 0.25 175 10.0 PVC Black

TSS02504H 4 x 2.5 50 x 0.25 175 10.0 LSHF Black

TSS02508 8 x 2.5 50 x 0.25 300 15.8 PVC Black

TSS02508H 8 x 2.5 50 x 0.25 300 15.8 LSHF Black

TSS04002 2 x 4.0 56 x 0.30 170 10.5 PVC Black

TSS04002H 2 x 4.0 56 x 0.30 170 10.5 LSHF Black

TSS04004 4 x 4.0 56 x 0.30 265 11.5 PVC Black

TSS04004H 4 x 4.0 56 x 0.30 265 11.5 LSHF Black

TSS04008 8 x 4.0 56 x 0.30 495 18.5 PVC Black

TSS04008H 8 x 4.0 56 x 0.30 495 18.5 LSHF Black

TSS06002 2 x 6.0 84 x 0.30 170 11.2 PVC Black

TSS06002H 2 x 6.0 84 x 0.30 170 11.2 LSHF Black

TSS01502

Colour Code - Multicore Circular Speaker Cable:

01 Red 02 Blue 03 Black 04 White

Cables with 7 cores and above are number coded

Low Smoke Halogen Free

CPR-Compliant Options Available

Tel: 01727 840 841

HA & AUDIO


36

TruSound External Grade Speaker Cable

TSS01504D

External Grade Speaker Cables

The FSC range of external grade speaker cables is suitable to be either run through ducts or clipped

to buildings or other exposed areas when an armoured cables not required. The cables are rated

to 0.6/1kV and have XLPE insulation, a water blocking gel tape, a PVC bedding and a UV stable

black polyethylene sheath which also gives additional mechanical strength and water resistance.

The colour code is the conventional for simple wiring and despite their toughness they remain

remarkably flexible.

The gel tape remains dry until exposed to water when it swells to form a water barrier. This prevents

any mess during termination normally associated with petroleum jelly filled cables.

The cable is stocked on bulk drums and can be cut to length to reduce your wastage and save time.

If these cables require added protection we can also armour them with MOQs as low as a hundred

metres. Please see page 206 for more details or call us with your specific requirements.

CONSTRUCTION

Plain copper wire conductors to IEC/BS EN 60228

class 5, XLPE colour coded insulation, water

blocking tape, bedding compound of PVC, UV

resistant polyethylene sheath.

TECHNICAL INFORMATION

Voltage Rating:

0.6/1kV

Conductor Stranding: IEC/BS EN 60228 class 5

Temperature Rating:

Bending Radius:

Static -20°C to +80°C

Flexing -5°C to +70°C

10 x overall diameter

Part No.

Cores x

mm 2

Stranding

No. x mm

Weight

kg/km

O/D mm

Colour

TSS01502D 2 x 1.5 30 x 0.25 105 9.7 Black

TSS01503D 3 x 1.5 30 x 0.25 156 10.4 Black

TSS01504D 4 x 1.5 30 x 0.25 181 11.3 Black

TSS02502D 2 x 2.5 50 x 0.25 154 11.0 Black

TSS02503D 3 x 2.5 50 x 0.25 183 11.8 Black

TSS02504D 4 x 2.5 50 x 0.25 241 13.0 Black

Duct Grade

CPR-Compliant Options Available

www.fscables.com | sales@fscables.com


TruSound Parallel Speaker Cable

37

Parallel Speaker Cables

TS804002

Designed for installations in pubs, clubs, gyms and public buildings as well as high-end domestic

properties, these parallel speaker cables provide easy termination due to the longitudinal core

identification. The high number of pure copper strands and low resistance values enable the

speaker to operate at optimum levels. The question when specifying is to check the purity of the

copper as it is this which gives the lowest resistance figure. In TruSound speaker cables only pure

electrolytic copper is used so it can be classed as OFC (Oxygen Free Copper).

Part No. Size mm 2 Stranding No.

x mm

Weight

kg/km

O/D mm

Cap

pF/m

Sheath

Material

Colour

TS800702 0.75 24 x 0.20 23 2.5 x 5.6 82 PVC Clear

TS800702H 0.75 24 x 0.20 23 2.5 x 5.6 82 LSHF White

TS801502 1.5 189 x 0.10 42 3.0 x 6.2 67 PVC Clear

TS801502H 1.5 189 x 0.10 42 3.0 x 6.2 67 LSHF White

TS802502 2.5 322 x 0.10 60 3.6 x 7.4 57 PVC Clear

TS802502H 2.5 322 x 0.10 60 3.6 x 7.4 57 LSHF White

TS804002 4.0 511 x 0.10 105 4.5 x 9.7 54 PVC Clear

TS806002 6.0 777 x 0.10 141 6.1 x 12.5 58 PVC Clear

TS810002 10.0 1260 x 0.10 252 7.0 x 15.0 62 PVC Clear

42 & 79 Strand Flat Speaker Cable

TSS79W

The 42 & 79 strand pure copper speaker cables offer a great entry-level product. Insulated in white

PVC with a polarity stripe down one leg, the cores are easy to separate and strip. Widely used in

pubs, clubs, leisure centres and retail for PA systems and background music, these cables are also

popular with home HiFi enthusiasts.

Part No. Size mm 2 Stranding

No. x mm

Weight

kg/km

O/D mm

Colour

TSS42W 1.3 42 x 0.20 40 3.0 x 6.3 White/Black

TSS79W 2.5 79 x 0.20 62 3.5 x 7.5 White/Black

Low Smoke Halogen Free

CPR-Compliant Options Available

Tel: 01727 840 841

HA & AUDIO


38

HD Media Composite Cables

HD Media Composite Cables

The expectations of entertainment systems in high-end residential and commercial properties are constantly rising.

Distribution and control of HD video, audio and broadband, flawlessly around large buildings and even to remote

locations requires the best equipment. The FSC series of Home Automation cables combine high performance coaxial

cables with Cat 5E or Cat 6 data cables and can now even include fibre optic cables for future flexibility and expansion –

all within a single sheath.

By incorporating all elements in one distinctive outer jacket, these cables offer greater protection and simpler installation

with future flexibility. The range of HA composite cables enables you to cover both immediate needs and future

demand. The FSC custom design facility also allows you to develop a cable to meet your specific requirements with

elements for audio, video, building control and data, even when the quantities are as low as 100m, normally delivered

within 2-3 weeks.

TECHNICAL SPECIFICATION FOR EACH ELEMENT

TV100 Coaxial Cable

Conductor:

Dielectric:

1st Screen:

2nd Screen:

Sheath:

Overall Diameter:

Impedance:

Bare Copper

Foamed PE

Copper/PET Foil

Plain Copper Wire Braid

PVC

6.6mm

75 Ohm

Nominal Capacitance: 52pF/ft ± 3

Velocity: 85%

Return Loss:

23 dB @ 5 - 470MHz

20 dB @ 470 - 862MHz

18 dB @ 862 - 2150MHz

Attenuation: 50MHz 4.6 dB/100m

460MHz 15.0 dB/100m

1000MHz 21.5 dB/100m

1750MHz 29.0 dB/100m

2150MHz 32.5 dB/100m

Fibre

No. of Fibres:

Fibre Size:

Tube:

Building Control Lighting Cable

Data Pair - White & Blue

Conductor:

Insulation:

Screen:

Power Core - Black & Red

Conductor:

Insulation:

Overall Sheath:

4 Fibre

Singlemode OS2 or Multimode

OM1, OM3 or OM4

1 Loose Tube

Other fibre combinations and sizes are available to order, please

contact us for more details

22(7)awg tinned copper

PE

Foil screened pair with drain wire

18(7)awg tinned copper

PVC

PVC

HDBaseT Recommended Cat 5E UTP 350MHz 4Pair

Conductor:

24awg Pure Copper

Insulation:

PE

Sheath:

PVC or LSHF

Overall Diameter: 5.0mm

Impedance: 100 Ohm ± 15

Complies with TIA/EIA 568-C.2 & ISO/IEC 11801

HDBaseT Recommended Cat 6 UTP 500MHz 4Pair

Conductor:

23awg Pure Copper

Insulation:

PE

Sheath:

PVC or LSHF

Overall Diameter: 6.2mm

Impedance: 100 Ohm ± 15

Complies with TIA/EIA 568-C.2 & ISO/IEC 11801

www.fscables.com | sales@fscables.com


HD Media Composite Cables

39

Part No.

No. of

Coaxes

No. of

Cat 5E

No. of

Cat 6

Other

Components

O/D

mm

Weight

kg/km

Sheath & Stripe

HA1

1 x Black

1 x White

1 x Blue

1 x Red

- - 16.8 210 Pink PVC & White Stripe

HA1

Part No.

No. of

Coaxes

No. of

Cat 5E

No. of

Cat 6

Other

Components

O/D

mm

Weight

kg/km

Sheath & Stripe

HA2

1 x Black

1 x White

1 x Blue

1 x Red

-

Grey 18awg +

22awg

Lighting Control

19.5 270 Pink PVC & Blue Stripe

HA2

Part No.

No. of

Coaxes

No. of

Cat 5E

No. of

Cat 6

Other

Components

O/D

mm

Weight

kg/km

Sheath & Stripe

HA3

1 x Black

1 x White

-

1 x Grey

1 x Violet

- 17.5 220 Pink PVC & Black Stripe

HA3

Part No.

No. of

Coaxes

No. of

Cat 5E

No. of

Cat 6

Other

Components

O/D

mm

Weight

kg/km

Sheath & Stripe

HA4

1 x Black

1 x White

1 x Red

1 x Grey

1 x Violet

- 18.2 250 Pink PVC & Green Stripe

HA4

CPR-Compliant Options Available

Tel: 01727 840 841

HA & AUDIO


40

HD Media Composite Cables

Part No.

No. of

Coaxes

No. of

Cat 5E

No. of

Cat 6

Other

Components

O/D

mm

Weight

kg/km

Sheath & Stripe

HA5

1 x Black

1 x White

1 x Red

1 x Grey

1 x Violet

- 17.2 250 Pink LSHF & Violet Stripe

HA5

Part No.

No. of

Coaxes

No. of

Cat 5E

No. of

Cat 6

Other

Components

O/D

mm

Weight

kg/km

Sheath & Stripe

HA6

1 x Black

1 x White

-

1 x Grey

1 x Violet

4 fibre Orange 16.6 235 Pink PVC & Brown Stripe

HA6

Part No.

No. of

Coaxes

No. of

Cat 5E

HA15 1 x Black -

No. of

Cat 6

1 x Grey

1 x White

1 x Red

Other

Components

O/D

mm

Weight

kg/km

Sheath & Stripe

- 17.5 226 Pink PVC & Yellow Stripe

HA15

CPR-Compliant Options Available

www.fscables.com | sales@fscables.com


HD Media Composite Cables

41

Part No.

No. of

Coaxes

No. of

Cat 5E

C6R3 - -

No. of

Cat 6

1 x Red

1 x Blue

1 x Yellow

Other

Components

O/D

mm

Weight

kg/km

Sheath & Stripe

- 14.5 160 Grey PVC

C6R3

Part No.

No. of

Coaxes

No. of

Cat 5E

C6R4 - -

No. of

Cat 6

1 x Red

1 x Blue

1 x Yellow

1 x White

Other

Components

O/D

mm

Weight

kg/km

Sheath & Stripe

- 16.9 190 Grey PVC

C6R4

Part No.

No. of

Coaxes

No. of

Cat 5E

C6R6 - -

No. of

Cat 6

1 x Red

1 x Blue

1 x Yellow

1 x White

1 x Green

1 x Grey

Other

Components

O/D

mm

Weight

kg/km

Sheath & Stripe

- 21.0 265 Grey PVC

C6R6

CPR-Compliant Options Available

Tel: 01727 840 841

HA & AUDIO


42

TruSound FSTP & Line Level Audio

TSFSTP0201

Foil Screened Twisted Pair (FSTP)

Developed for analogue and digital audio transmissions this cable has a foil screen with a 100%

coverage around the single pair to ensure low signal distortion, the foil screen is bonded to the

outer sheath so when stripped back the outer sheath and screen come off together which makes

for quick and easy termination. Flexibility is maintained due to the soft materials used on the outer

sheath.

Part No.

Size AWG

No. of

Pairs

Weight

kg/km

O/D mm

Sheath

Material

Colour

TSFSTP0201 24(7) 1 21 4.0 PVC Black

TSFSTP0201H 24(7) 1 21 4.0 LSHF Black

Line Level Audio

Designed for fixed installations which connect line level audio equipment, FSC hold a range of

individually screened paired cables which reduces cross talk between each pair and other equipment

nearby to ensure you get the highest performance possible. With large stocks of either standard

PVC/LSF cables or versions for use in public buildings with a Low Smoke Halogen Free (LSHF) sheath

you are sure to find the one you need. Also stocked are types suitable for outdoor use with heavy

PE jackets, we can usually oversheath the standard cable for quantities as low as 100m. Please call

us to discuss your requirement further.

2202PIFRL

Part No.

Size

AWG

No. of

Pairs

Screen

Weight

kg/km

O/D

mm

Sheath

Material

Colour

2201POFPL 22(7) 1 Overall Foil 25 4.5 LSF Grey

2201POFRL 22(7) 1 Overall Foil 20 3.5 LSF Grey

2201POFRH 22(7) 1 Overall Foil 20 3.5 LSHF Grey

2001POFPL 20(7) 1 Overall Foil 35 5.2 LSF Grey

2001POFPH 20(7) 1 Overall Foil 35 5.2 LSHF Grey

1801POFPL 18(16) 1 Overall Foil 45 5.6 LSF Grey

1801POFPH 18(16) 1 Overall Foil 45 5.6 LSHF Grey

1601POFPL 16(19) 1 Overall Foil 84 7.9 LSF Grey

1601POFPH 16(19) 1 Overall Foil 84 7.9 LSHF Grey

1401POFPL 14(19) 1 Overall Foil 109 9.0 LSF Grey

1401POFPH 14(19) 1 Overall Foil 109 9.0 LSHF Grey

2202PIFRL 22(7) 2 Individual Screened Pairs 32 4.2 LSF Grey

2202PIFRH 22(7) 2 Individual Screened Pairs 32 4.2 LSHF Grey

2203PIFRL 22(7) 3 Individual Screened Pairs 70 6.9 LSF Grey

2203PIFRH 22(7) 3 Individual Screened Pairs 70 6.9 LSHF Grey

2206PIFRL 22(7) 6 Individual Screened Pairs 123 9.2 LSF Grey

2206PIFRH 22(7) 6 Individual Screened Pairs 123 9.2 LSHF Grey

2212PIFRL 22(7) 12 Individual Screened Pairs 226 11.8 LSF Grey

2212PIFRH 22(7) 12 Individual Screened Pairs 226 11.8 LSHF Grey

Low Smoke Halogen Free

CPR-Compliant Options Available

www.fscables.com | sales@fscables.com


TruSound Microphone & Star Quad

43

Microphone Cables

TSM02020

Microphone cables come in many shapes and sizes. Super flexibility even at low temperatures is

achieved through the use of a special insulation and highly flexible cotton fillers to maintain a

constant capacitance and avoid noise when the cable flexes. The super flexible jacket also offers

resistance against kinking and lies flat on stage.

The spiral copper shield offers excellent screening whilst remaining flexible and providing

mechanical support when the cable is under physical stress. The four core microphone cables are a

star quad format.

Part No.

Cores x

mm 2

Stranding

No. x mm

Weight

kg/km

O/D mm

Colour

TSM02020 2 x 0.22 28 x 0.10 45 6.0 Black

TSM02040 4 x 0.22 28 x 0.10 55 6.5 Black

TSM03020 2 x 0.34 40 x 0.10 52 6.5 Black

TSM03040 4 x 0.34 40 x 0.10 64 6.8 Black

Multiple Star Quad Cables

Designed for longer runs where it is beneficial to run a number of signals down a single cable using

the star quad format. These cables are highly flexible and robust enough for touring applications.

Part No.

Cores x

mm 2

Stranding

No. x mm

Screening

Weight

kg/km

O/D

mm

Colour

TSQ01010 1 x 4 x 0.15 19 x 0.10 Overall Braid 45 5.5 Black

TSQ02010 1 x 4 x 0.22 28 x 0.10 Overall Braid 60 6.5 Black

TSQ01010H 1 x 4 x 0.18 7 x 0.18 Overall Foil 45 4.7 Black

TSQ05010H 1 x 4 x 0.50 28 x 0.15 Overall Braid 60 6.5 Black

TSQ01040H 4 x 4 x 0.18 7 x 0.18 Individual Foil 150 11.6 Grey

TSQ01080H 8 x 4 x 0.18 7 x 0.18 Individual Foil 240 15.5 Grey

TSQ01012H 12 x 4 x 0.18 7 x 0.18 Individual Foil 425 19.3 Grey

TSM03040

Multipair versions up to 30 pair are available with or without individual pair screens.

LSHF versions are also offered for use in sensitive areas or where local regulations require.

Snake cables are shown on page 44.

Low Smoke Halogen Free

Tel: 01727 840 841

HA & AUDIO


44

Snake Cables & DMX

TSSN0208

Snake Cables

Snake cables are multicore audio cables usually linking a number of individual microphone cables

or audio feeds back to the mixing desk. Ideal for either fixed installation in permanent venues or on

temporary installations when the cables will be coiled up and stored after the show.

Part No.

Pairs x AWG

Stranding

No. x mm

Weight

kg/km O/D mm Sheath

Material

Colour

TSSN0202 2 x 2 x 24 7 x 0.20 68 8.1 PVC Black

TSSN0204 4 x 2 x 24 7 x 0.20 100 9.4 PVC Black

TSSN0208 8 x 2 x 24 7 x 0.20 183 12.3 PVC Black

TSSN0212 12 x 2 x 24 7 x 0.20 256 14.9 PVC Black

TSSN0216 16 x 2 x 24 7 x 0.20 345 17.1 PVC Black

TSSN0220 20 x 2 x 24 7 x 0.20 420 19.0 PVC Black

TSSN0224 24 x 2 x 24 7 x 0.20 486 21.7 PVC Black

TSSN0232 32 x 2 x 24 7 x 0.20 630 24.1 PVC Black

TSSN0240 40 x 2 x 24 7 x 0.20 780 26.2 PVC Black

DMX Cables

Developed to ensure accurate transmission of digital AES/EBU audio signals and digital DMX control

signals, these cables are used extensively in the entertainment industry. DMX is designed to work

between 90Ω and 120Ω impedance. The level of shielding enables interference-free transmission

even over long distances. The tough physical properties of the TruSound DMX cable make it one of

the best products on the market.

TSD02010

Part No. Pairs x mm 2 No. of Power

Cores x mm 2

Weight

kg/km O/D mm Sheath

Material

Colour

TSD02010 1 x 2 x 0.22 - 50 6.0 PVC Black

TSD02011 1 x 2 x 0.22 - 50 6.0 PVC Blue

TSD02020 2 x 2 x 0.22 - 75 8.0 PVC Black

TSD02150 1 x 2 x 0.22 3 x 1.5 275 15.2 PVC Black

TSD02250 1 x 2 x 0.22 3 x 2.5 370 17.5 PVC Black

TSD022110 4 x 2 x 0.22 3 x 2.5 460 18.2 PVC Black

Please note some of the cables above are also available in Low Smoke Halogen Free.

www.fscables.com | sales@fscables.com


45

BMS

Introduction

Building Management Control or Building

Automation operates at the core of a building’s

energy efficiency and usability.

With a myriad of different systems controlling

everything from lighting, HVAC, blind control

through to security systems and occupancy

monitoring, many installers and designers are

insisting on hard-wired systems for reliability and

practicality.

System manufacturers are increasingly standardising

on cables designed to carry data and power in a

single cable to making routing and installation fast

and simple. With open protocols from organisations

such as KNX and Dali, many systems will interface

seamlessly with a variety of manufacturers

equipment.

Contents

Simmtronic Specs 3 46

Trend 47

KNX 48

Lighting & Blind Control 49

Crestron, Control4 & Thorn 50

Honeywell & Loxone 51

DALI Lighting Control 52

Echelon LonWorks 53

With applications ranging from large office blocks,

hospitals, prisons and shopping centres, right

through to residential dwellings and multiple

dwelling units the use of BMS is set to grow in

our quest for greater efficiency linked to greater

comfort and convenience.

Many of the FSC range of BMS cables are Low

Smoke Halogen Free to minimise risk in the event of

a fire, making them ideal for use in public buildings.

They are also all classified to CPR where relevant.

Tel: 01727 840 841

BMS


46

Simmtronic Specs 3

Simmtronic Specs 3

FSC and Simmtronic have worked closely together to develop the Simmtronic SPECS3 cable range. As the only cables

endorsed by Simmtronic you can be confident you are fitting the best and that they will work first time, manufactured to

match the Ensto connectors perfectly.

New to the market is an E-Bus version fully compliant with requirements of CPR class Cca s1a, d1, a1 for higher CPR

building specifications. The entire range is printed with the Simmtronic logo as a sign of quality together with the CPR

classification.

1801PUYH07

CONSTRUCTION

E-Bus blue

1801PUYH01 - 1 pair 18AWG unscreened cable. Colour coded blue for fast identification this version of E-Bus

provides a DALI control pair for the SPECS 3 system. Low Smoke Halogen Free (LSHF) throughout.

E-Bus white

1801PUYH04 - 1 pair 18AWG unscreened cable. Coloured white for general applications, standard E-Bus is used

for connection of switches and sensors on the SPECS 3 system. LSHF throughout.

O-Bus/M-Bus pink

1801PUYH07 - 1 pair 18AWG unscreened cable for communications from the SPX 310 area controller and the

SPV.9 lighting control modules. Also used for O-Bus connections. LSHF throughout.

C-Bus grey

2201POFPH05 - 1 pair 22AWG screened cable for connection of SPX 310 area controllers and SPG.2 gateway

modules on legacy systems. LSHF throughout.

T-Bus grey

2202PTFRH - 2 pair 22AWG individual and overall foil screen for dual connections of SPX310 area controllers and

SPG.2 gateway modules. LSHF throughout.

1801PUYH04

Part No.

No. of

Pairs

System AWG Screen

Sheath

Material

Sheath

Colour

Weight

kg/km

1801PUYH01 1 E-Bus 18 U/UTP LSHF Blue 37 5.6

1801PUYH04 1 E-Bus 18 U/UTP LSHF White 37 5.6

1801PUYH01-C04* 1 E-Bus 18 U/UTP LSHF Blue 40 6.2

1801PUYH04-C04* 1 E-Bus 18 U/UTP LSHF White 40 6.2

1801PUYH07-C04* 1 O-Bus/M-Bus 18 U/UTP LSHF Pink 40 6.2

1801PUYH07 1 O-Bus/M-Bus 18 U/UTP LSHF Pink 37 5.6

2201POFPH05 1 C-Bus 22 F/UTP LSHF Grey 25 4.6

2202PTFRH 2 T-Bus 22 F/FTP LSHF Grey 42 5.5

O/D

mm

D-Power

1801PUYH01D1 - 1 pair 18AWG unscreened cable which is used for switches, sensors and a DALI control on the

SPECS3 system while the 3 x 1.5mm² or 2.5mm² is for powering the luminaries. The D-Power cable is ideal for

tidy installation in open ceiling offices and applications where cable remains on show.

Part No.

Description

Sheath

Material

Sheath

Colour

Weight

kg/km

1801PUYH01D1 1801PUYH01 + 3 x 1.5mm² LSHF White 110 11.4

1801PUYH02D2 1801PUYH01 + 3 x 2.5mm² LSHF White 145 12.6

O/D

mm

* Meets CPR classification Cca, s1a, d1, a1 and BS6701:2016+A1:2017

Low Smoke Halogen Free

CPR-Compliant Options Available

www.fscables.com | sales@fscables.com


Trend

47

Trend

The Trend Building Energy Management Systems (BEMS) are aimed at the commercial sector with a focus on reducing

energy consumption and CO2 emissions. Markets include education, healthcare, data centres, retail, sport & leisure as

well as offices and commercial buildings. To support the Trend systems, the FSC range of cables are all Low Smoke

Halogen Free (LSHF) and CPR-compliant.

CONSTRUCTION - 1601PUYH06

Tinned copper stranded conductor 16(19) AWG,

LSHF insulation, twisted into a pair, LSHF violet

sheath.

TECHNICAL INFORMATION

Voltage Rating:

Colour Code:

Temperature Rating:

Nominal Capacitance:

300V

CE: 450/750V†

Black & White

+60°C

Core to core 108pF/m

2202PIFRH06

CONSTRUCTION - 2201POFPH06

Tinned copper conductor 22(7) AWG, polyethylene

insulation, twisted pair, aluminium/polyester foil

screen, tinned copper drain wire, LSHF violet

sheath.

TECHNICAL INFORMATION

Voltage Rating:

Colour Code:

Temperature Rating:

Nominal Capacitance:

300V

CE: 450/750V†

Black & Clear

+60°C

Core to core 79pF/m

Core to screen 154pF/m

CONSTRUCTION - 2202PIFRH06

Tinned copper conductor 22(7) AWG 0.35mm²,

polypropylene insulation, twisted into pairs, each

pair aluminium/polyester foil screened, common

tinned copper drain wire (24AWG), LSHF violet

sheath.

CONSTRUCTION - 2401POHPH06

Tinned copper conductor 24(7) AWG 0.22mm²,

polyethylene insulation. Twisted into pairs, overall

aluminium/polyester foil screened, tinned copper

drain wire (24AWG), overall tinned copper braid

(90%), LSHF violet sheath.

TECHNICAL INFORMATION

Voltage Rating:

Colour Code:

Impedance:

Temperature Rating:

Nominal Capacitance:

TECHNICAL INFORMATION

Voltage Rating:

Colour Code:

Impedance:

Temperature Rating:

Nominal Capacitance:

300V

CE: 450/750V†

Red/Black, White/Green

45 Ohms

+60°C

Core to core 115pF/m

Core to screen 203pF/m

300V

CE: 450/750V†

Blue/White Stripe,

White/Blue Stripe

120 Ohms

+60°C

Core to core 42pF/m

Core to screen 76pF/m

2401POHPH06

Part No.

Alt. to Trend

No. of

Pairs

AWG

Screen

Sheath

Material

Sheath

Colour

Weight

kg/km

1601PUYH06 TP/1/0/16/HF 1 16 Unscreened LSHF Violet 56 7.0

2201POFPH06 TP/1/1/22/HF 1 22 Overall Foil LSHF Violet 25 4.5

2202PIFRH06 TP/2/2//22/HF 2 22 Ind. Foil Pairs LSHF Violet 32 4.2

2401POHPH06 TP/1/1/24/HF 1 24 Ovrl. Foil & Braid LSHF Violet 64 5.9

O/D

mm

† Applies to CE marked FSC branded stock only

Low Smoke Halogen Free

CPR-Compliant Options Available

Tel: 01727 840 841

BMS


48

KNX

KNX Cable

KNX is an open protocol, currently there are over 400 manufacturers producing products that will work together to

provide a complete Building Automation System (BAS). Controlling heating, ventilation, lighting, blinds, security systems,

audio & video as well as white goods. KNX system providers can monitor or control every aspect of a building’s use of

energy, making it more efficient and greener.

FSC stocks KNX certified cable and is a member of the KNX Association. The majority of the cables are 2 pair with solid

conductors of plain copper with an overall foil screen and stranded tinned copper drain wire. A single pair cable, with a

reduced outer diameter, is also available from stock, often used as a jumper or patch cable. The majority of KNX cables

stocked by FSC are Low Smoke Halogen Free (LSHF), a London Underground approved version is also available as are

outdoor and armoured (SWA) options.

31000502H

KNX Cable

CONSTRUCTION

Solid bare copper conductors, 0.8mm diameter,

polyethylene insulation, twisted into pairs,

pairs laid up with fillers if neccessary, polyester

tape, stranded tinned copper drain wire, overall

aluminium/polyester tape screen, LSHF sheath.

TECHNICAL INFORMATION

Voltage Rating: CE: 450/750V†

Temperature Rating: -20°C to +70°C

Capacitance:

90pF/m

Flame Retardant: IEC/BS EN 60332-1

Smoke Emission: IEC/BS EN 61034-2

Halogen Emission: IEC/BS EN 60754-1&2

Part No.

No. of

Pairs

Sheath

Material

Sheath

Colour

Approval

Weight

kg/km

O/D

mm

31000501H 1 LSHF Green KNX Association 40 5.2

31000502H 2 LSHF Green KNX Association 62 6.8

31000502HLU 2 LSHF Green KNX Association + LU 62 6.8

31000502H04 2 LSHF White KNX Association 62 6.8

31000502H-C04* 2 LSHF Green KNX Association 68 6.8

31000502D 2 PE Black KNX Association 95 9.2

31000502A 2 SWA/PE Black KNX Association 300 13.0

31000502A

KNX Jumper Cables

CONSTRUCTION

Solid bare copper conductors, 0.8mm diameter,

polyethylene insulation, twisted into a pair,

polyester tape, stranded tinned copper drain wire,

overall aluminium/polyester tape screen, LSHF

sheath.

TECHNICAL INFORMATION

Voltage Rating: CE: 450/750V†

Temperature Rating: -20°C to +70°C

Capacitance:

90pF/m

Flame Retardant: IEC/BS EN 60332-1

Smoke Emission: IEC/BS EN 61034-2

Halogen Emission: IEC/BS EN 60754-1&2

Part No.

No. of

Pairs

Sheath

Material

Sheath

Colour

Length mm

Weight

kg/km

31000501H190 1 LSHF Green 190 40 5.2

31000501H320 1 LSHF Green 320 40 5.2

O/D

mm

* Meets CPR classification Cca, s1a, d1, a1 and BS6701:2016+A1:2017

† Applies to CE marked FSC branded stock only

Low Smoke Halogen Free Duct Grade SWA

CPR-Compliant Options Available

www.fscables.com | sales@fscables.com


Lighting & Blind Control

49

Lighting & Blind Control Control Cable

A range of lighting, blind and building control cables are widely used by a number of manufacturers around the world.

Aimed at high-end residential, retail and commercial applications as well as restaurants and health care.

By using a single cable that combines 18awg power cores with a screened 22awg twisted pair for signalling, the cable is

neat and quick to install. Manufactured for indoor applications using flame retardant, Low Smoke Halogen Free (LSHF)

materials the cables are classified to CPR. For outdoor use duct grade or armoured (SWA) versions are also stocked. For

long runs or high-power requirements, 16awg and 12awg are also available.

Lighting Control Cable

CONSTRUCTION

POWER PAIR

Conductors: 12(7) or 18(7)AWG bare copper

Insulation: Polyethylene

Colour Code: Red & black

TECHNICAL INFORMATION

Voltage Rating: 300V

Temperature Rating: 0°C to +60°C

Flame Retardant: IEC/BS EN 60332-1

Smoke Emission: IEC/BS EN 61034-2

Halogen Emission: IEC/BS EN 60754-1&2

DATA PAIR

Conductors:

Insulation:

Screen:

Colour Code:

Nominal

Capacitance:

Impedance:

22(7)AWG bare copper

Polyethylene

Overall Aluminium Foil

Violet & White

Core to core 80pF/m

Core to screen 160pF/m

150 Ohm nominal

1822LCCH

Part No.

Description

Sheath

Material

Sheath

Colour

Weight

kg/km

1222LCCH 2core 12AWG + 1core 18AWG + 1pair 22AWG LSHF Blue 81 8.0

1822LCCH 2core 18AWG + 1pair 22AWG LSHF Blue 46 5.0

1822LCCHD 2core 18AWG + 1pair 22AWG Duct Grade PE Black 66 7.4

1822LCCHA 2core 18AWG + 1pair 22AWG SWA SWA/PE Black 120 11.5

O/D

mm

Blind Control Cable

CONSTRUCTION

POWER PAIR

Conductors: 16(26)AWG bare copper

Insulation: Polyethylene

Colour Code: Red & black

TECHNICAL INFORMATION

Voltage Rating: 300V

Temperature Rating: 0°C to +60°C

Flame Retardant: IEC/BS EN 60332-1

Smoke Emission: IEC/BS EN 61034-2

Halogen Emission: IEC/BS EN 60754-1&2

DATA PAIR

Conductors:

Insulation:

Screen:

Colour Code:

Nominal

Capacitance:

22(16)AWG bare copper

Polyethylene

Overall Aluminium Foil

Violet & White

Core to core 67pF/m

Core to screen 145pF/m

1622LCCH

Part No.

Description

Sheath

Material

Sheath

Colour

Weight

kg/km

1622LCCH 2core 16AWG + 1pair 22AWG LSHF White 70 6.3

O/D

mm

Low Smoke Halogen Free Duct Grade SWA

CPR-Compliant Options Available

Tel: 01727 840 841

BMS


50

Crestron, Control4 & Thorn

Crestron, Control4 & Thorn Lighting Control

1822CCCH

Crestron Lighting Control Cable

Popular for use on the Creston control systems for lighting, blind control, sensors and keypads the

Cresnet ® compatible cable offers small dimensions and a distinctive teal jacket with a yellow stripe.

The FSC version is made using Low Smoke Halogen Free (LSHF) materials making it ideal for use in

public and residential buildings.

CONSTRUCTION

POWER PAIR

Conductors:

Insulation:

Colour Code:

18(7)AWG bare copper

LSHF

Red & Black

TECHNICAL INFORMATION

Voltage Rating: 300V

CE: 450/750V†

Temperature Rating: -20°C to +70°C

Nominal Impedance: 100 Ohm

Nominal Capacitance: Core to core 41pF/m

DATA PAIR

Conductors:

Insulation:

Screen:

Colour Code:

22(7)AWG bare copper

Foamed polyethylene

Overall Aluminium Foil

White & Blue

Flame Retardant: IEC/BS EN 60332-1

Smoke Emission: IEC/BS EN 61034-2

Halogen Emission: IEC/BS EN 60754-1&2

Part No.

Alternative to

Sheath

Material

Sheath

Colour

Weight

kg/km

1822CCCH CRESNET-NP LSHF Teal 46 6.4

O/D

mm

Control4 Lighting Control Cable

28101502

If you are installing a Control4 or Mode Lighting system, we offer an alternative to Belden 1502R.

The cable is electrically the same as our Lighting Control Cable on page 49 with a reduced overall

diameter for easy routing. The SWA & duct grade versions are designed for external use and have a

UV resistant PE waterproof outer jacket.

Part No. Alt. to Belden No. of Pairs AWG

Sheath

Material

Sheath

Colour

Weight

kg/km

1822ECC 1502R 2 18/22 PVC Blue 65 6.4

1822ECCH 1502SB 2 18/22 LSHF Blue 65 6.4

1822ECCD 1502R 2 18/22 PE Black 79 8.8

1822ECCA 1502R 2 18/22 SWA/PE Black 120 10.6

O/D

mm

Thorn Lighting Control Cable

Designed for the Thorn lighting control system this is probably the simplest lighting cable we supply.

It’s LSHF and uses class 5 stranded plain copper flexible conductors for easy routing and termination.

CONSTRUCTION

Conductors: 1.5mm² class 5 bare copper

Insulation: Polyethylene

Colour Code: Red & black

TECHNICAL INFORMATION

Voltage Rating: 450/750V†

Temperature Rating: -20°C to +70°C

Nominal Capacitance: Core to Core 48pF/m

Part No. Cores x mm 2 Sheath

Material

Sheath

Colour

Weight

kg/km

O/D mm

28101502 2 x 1.5 LSHF Ivory 26 8.2

† Applies to CE marked FSC branded stock only

Low Smoke Halogen Free Duct Grade SWA

CPR-Compliant Options Available

www.fscables.com | sales@fscables.com


Honeywell & Loxone Systems

51

Honeywell Door Entry Cable & Tree Cable Designed for Loxone Systems

Honeywell Door Entry Cable

To meet the needs of installers of Honeywell equipment, FSC now stock a new door entry cable.

With an overall screen and 6 cores of 18(7) AWG, this PVC data cable is designed for use on card

reader systems, connecting the reader where a card is swiped to the processor. As an alternative

to Belden 5304FE, it is compatible with Win-PAK ® , Nstar and Pro-Watch ® software and N1000,

NetAXS panels, Pro2200 and PW6000 hardware panels. It can also be used on any card reader

system using the same Wiegand format.

1806COFRH

CONSTRUCTION - SINGLE PAIR

Plain copper stranded conductor, polypropylene

insulation, cores twisted together, overall

aluminium/polyester foil screeen, tinned copper

drain wire (24AWG), PVC/LSF or Low Smoke

Halogen Free (LSHF) sheath.

TECHNICAL INFORMATION

Voltage Rating:

Temperature Rating:

Capacitance:

300V

CE: 450/750V†

-20°C to +70°C

Core to core 89pF/m

Core to screen 159pF/m

Colour Code: Chart 1 page 210

Part No.

Alt. to

Belden

No. of

Cores

AWG

Sheath

Material

Sheath

Colour

Weight

kg/km

1806COFRL 5304FE 6 18 PVC/LSF Blue 63 5.8

1806COFRH 5304FE 6 18 LSHF Blue 63 5.8

O/D

mm

1806COFRL Honeywell part number: 2216

1806COFRH Honeywell part number: 3216

Many other cables suitable for Honeywell, access control, intruder detection and video surveillance

systems are available.

Tree Cable Designed for Loxone Systems

The Loxone system is aimed at making home automation usable and affordable for mid and highend

residential properties. It links lighting, shading, heating, ventilation, AV, security and so much

more, to provide an intelligent approach to building management. By using twin 1.5mm² power

cores and data pairs for signal and control the Loxone Tree compatible cable design provides the

perfect, simple wiring solution. A single distinctive green sheathed cable, now available in LSHF as

well as the standard PVC, packed on 100m, 200m, or 500m reels. Cables can be Armoured and

Sheathed with LDPE for quantities as low as 100m.

1523LLCH

CONSTRUCTION

POWER PAIR

Conductors:

Insulation:

Colour Code:

TECHNICAL INFORMATION

Voltage Rating:

Temperature Rating:

1.5mm² class 5 bare copper

PVC or LSHF

Orange, White/Orange

300V

-30°C to +70°C

DATA PAIR

Conductors:

Insulation:

Colour Code:

0.6mm solid bare copper

PVC or LSHF

Orange, White/Orange

Green, White/Green

Part No.

Alt. to

Loxone

Description

Sheath

Material

Sheath

Colour

Weight

kg/km

1523LLC 100344 2 x 1.5mm² + 2pair PVC Green 78 7.5

1523LLCH 100344 2 x 1.5mm² + 2pair LSHF Green 78 7.5

O/D

mm

† Applies to CE marked FSC branded stock only

Low Smoke Halogen Free

CPR-Compliant Options Available

Tel: 01727 840 841

BMS


52

DALI Lighting Control Cable

DALI Lighting Control Cable

DALI is an acronym for Digital Addressable Lighting Interface and like KNX, is an open protocol which is why so many

lighting manufacturers around the world have adopted it. By making the fittings addressable the system can be very

easily reconfigured, control can be influenced by pre-programmed lighting requirements, occupancy sensors, available

daylight sensors and lighting needs in the event of evacuation.

All FSC DALI cables are Low Smoke Halogen Free (LSHF).

1801PUYH

DALI Lighting Control Cable

CONSTRUCTION - SINGLE PAIR

Tinned copper stranded conductor, LSHF

insulation, twisted into a pair, LSHF sheath.

TECHNICAL INFORMATION

Voltage Rating: 20AWG -16AWG: 300V

14AWG:

600V

CE: 450/750V†

Colour Code:

20AWG -18AWG: Black & Red

16AWG -14AWG: Black & White

Part No.

Alt. to

Belden

No. of

Pairs

AWG

Sheath

Material

Sheath

Colour

Weight

kg/km

2001PUYH 8205NH 1 20(7) LSHF Grey 26 4.6

1801PUYH 9740NH 1 18(16) LSHF Grey 37 5.6

1601PUYH 8471NH 1 16(19) LSHF Grey 56 7.0

1401PUYH 8473NH 1 14(42) LSHF Grey 89 8.6

O/D

mm

3180150504DL

DALI Lighting Control Cable

CONSTRUCTION

Fine copper wire strands to IEC/BS EN 60228 class

5, LSHF insulation, white LSHF outer sheath.

TECHNICAL INFORMATION

Voltage Rating: 300/500V Test 3000V

Temperature Rating:

Bending Radius:

Current Rating:

-5°C to +70°C

Flexing 12 x cable diameter

Static 6 x cable diameter

Refer to IEE Regs Table 4F3A&B

Flame Retardant: IEC/BS EN 60332-1-2

Smoke Emission: IEC/BS EN 61034-2

Halogen Emission: IEC/BS EN 60754-1 & 2

& 50267-2-1

Manufactured to: BS EN 50525-3-11

Part No. Cores x mm 2 Sheath

Material

Sheath

Colour

Weight

kg/km

O/D mm

3180100504DL 5 x 1.0 LSHF White 120 8.6

3180150504DL 5 x 1.5 LSHF White 174 10.3

3180100604 6 x 1.0 LSHF White 150 9.5

3180150604 6 x 1.5 LSHF White 212 11.4

5 core

6 core

Blue Brown Green/Yellow Red White

Blue Brown Green/Yellow Black Red White

Low Smoke Halogen Free

CPR-Compliant Options Available

www.fscables.com | sales@fscables.com


Echelon LonWorks

53

Echelon LonWorks

A range of single pair Bus cables are available for the LonWorks system allowing convenient wiring via the Free Topology

concept. Due to the popularity of the system for building management applications in the public sector these cables

are now stocked in Low Smoke Halogen Free (LSHF) versions. Duct grade PE sheaths and SWA options can also be

manufactured for quantities as low as 100m.

Available as one and two pair cables, screened and unscreened, they provide the ideal low cost solution to Bus wiring.

CONSTRUCTION - 16AWG

Tinned copper stranded conductor 16(19)AWG,

PVC/LSF insulation on standard cable, twisted into

a pair, PVC/LSF sheath.

TECHNICAL INFORMATION

Voltage Rating:

Colour Code:

300V

CE: 450/750V†

Black & White

1601PUYH

Part No.

Alt. to

Belden

No. of

Pairs

AWG

Sheath

Material

Weight

kg/km

O/D

mm

Sheath

Colour

1601PUYL 8471 1 16(19) LSF 56 7.0 Grey

1601PUYH 8471 LSHF 1 16(19) LSHF 56 7.0 Grey

1601PUYD 8471 Duct 1 16(19) PE 89 9.4 Black

1601PUYA 8471 SWA 1 16(19) PE 280 13.4 Black

CONSTRUCTION - 22AWG UNSCREENED

Solid plain copper stranded conductors 22(1)AWG,

foamed polyethylene insulation, cores twisted into

pairs, LSHF sheath.

TECHNICAL INFORMATION

Voltage Rating:

Temperature Rating:

300V

CE: 450/750V†

+60°C

Colour Code: Chart 5 page 210

Part No.

Alt. to

Belden

No. of

Pairs

AWG

Sheath

Material

Weight

kg/km

O/D

mm

Sheath

Colour

2201PUGH 7701NH 1 22(1) LSHF 14 3.5 White

2201PUGD 7701 Duct 1 22(1) PE 19 5.4 Black

2202PUGH 7702NH 2 22(1) LSHF 27 5.0 White

2202PUGD 7702 Duct 2 22(1) PE 35 6.7 Black

2202POFGH

CONSTRUCTION - 22AWG SCREENED

Solid plain copper stranded conductors 22(1)AWG,

foamed polyethylene insulation, cores twisted

into pairs, overall aluminium/polyester foil screen,

tinned copper drain wire (24AWG), LSHF sheath.

TECHNICAL INFORMATION

Voltage Rating:

Temperature Rating:

300V

CE: 450/750V†

+60°C

Colour Code: Chart 5 page 210

Part No.

Alt. to

Belden

No. of

Pairs

AWG

Sheath

Material

Weight

kg/km

O/D

mm

Sheath

Colour

2201POFGH 7703NH 1 22(1) LSHF 23 4.5 White

2201POFGD 7703 Duct 1 22(1) PE 29 6.4 Black

2202POFGH 7704NH 2 22(1) LSHF 36 6.5 White

2202POFGD 7704 Duct 2 22(1) PE 43 8.3 Black

† Applies to CE marked FSC branded stock only

Low Smoke Halogen Free Duct Grade SWA

CPR-Compliant Options Available

Tel: 01727 840 841

BMS


CUT TO

LENGTH

BUY WHAT

YOU NEED

SAVE MONEY

NO WASTE


55

Fire & Security

Introduction

When it comes to alarm or security cables, quality

really counts. At FS Cables, the focus is on cables

that will do the job they’re designed to do, without

false alarms or more importantly, failures when

alarm conditions are triggered. In short, you will get

products you can rely on from Prysmian, Draka or

FSC own brand.

Customers increasingly require installations that

minimise the risk in the event of a fire and to

this end FSC stock flame retardant and Low

Smoke Halogen Free (LSHF) versions meeting CPR

classifications. LSHF must not be confused with LSF

grade which are normally PVC based (more of this

on page 85).

For applications that run outside the confines of a

building or where vandalism or rodent damage is a

problem duct grade and armoured versions are also

stocked in many types.

Fire alarm, emergency lighting and critical circuits

are all covered by the extensive, market leading,

Prysmian range of FP cables, and Draka Firetuf,

stocked on handy 100m, 200m or 500m reels.

Contents

Draka Firetuf Data & Coax 56

Prysmian FP100 57

Prysmian FP200 Gold 58

Draka FT30 Saffire 59

Prysmian FP Plus 60

Draka FT120 61

Prysmian FP600S 62

Access Control Cables 63

Unscreened & Screened

Burglar Alarm Cables

64 & 65

Outdoor Data & Coaxial 66

Armoured Data & Coaxial 67

Outdoor Control 68

Composite Coaxial & Door Entry

Cable

69

Tel: 01727 840 841

FIRE & SECURITY


56

Draka Firetuf Data & Coaxial

Draka Firetuf Data & Coaxial

Firetuf data is a group of high performance fire survival data cables manufactured by Draka and designed to carry on

functioning even in the event of a fire. This allows safe monitoring of evacuation routes without putting lives at risk.

The twisted pair cables provide high data transmission rates and have been developed to mimic Cat 5 cabling as closely

as possible. Increasingly popular with system integrators for BMS applications, the cables can be terminated using

traditional LAN Insulation Displacement Connector (IDC) modules making them ideal for use in horizontal backbone

wiring systems in offices and public buildings.

Where video is carried the coax performs in a similar way to RG59 which is widely used in the CCTV sector. This allows

continued monitoring of fire exits and evacuation routes in the event of a fire. BNC connectors part no. YFTCBC1# are

available to suit Firetuf Coax.

Where people and property come first the Draka Firetuf Data cable range provides the ideal solution.

387FTD403

387FTD5903

TECHNICAL INFORMATION

Design:

Flame Retardant:

Smoke Emission: IEC/BS EN 61034-2

Generally to ISO/IEC 11801:95, EN 50173 95 and EN 50288-2-1. Suitable for

standard insulation displacement connector L.A.N. sockets. RS-485 10Mb/s

IEC/BS EN 60332-1-2, IEC/BS EN 60332-3-24C

Halogen Emission: IEC/BS EN 60754-1&2, EN 50267-2-2,

LU 1-085 A2 - toxic fume emissions

Fire Resistant: BS 5839 Clause 26.2E > 2hrs @ 950°C

BS 6387 > 3hrs @ 950°C

IEC 60331-23 > 3hrs @ 750°C

BS EN 50200 > 3hrs @ 950°C

BS EN 50200:2000

BS 8438-2:2003

BS 8438-2 Class PH120 (120 minutes)

BS 5839-1 2002 +A2 2008

London Underground

Standard:

Firetuf Data

FSC Part No.

LU 1-085-A2 fire safety performance of materials. Approved for use below ground

without restriction.

CONSTRUCTION

22(1)AWG solid plain copper conductor, PE/silicone rubber composite insulation,

cores twisted into pairs, pairs laid up, woven glass tape, aluminium screen in

contact with stranded tinned copper drain wire, tinned copper wire braid, Low

Smoke Halogen Free sheath - red or white. Colour code: Chart 5 page 210

Draka

Part No.

Type

Draka Part

No. 2

Sheath

Colour

Weight

kg/km

387FTD103 910234 1 Pair 0.63mm [22(1)AWG] 60018006 Red 48 6.8

387FTD203 910244 2 Pair 0.63mm [22(1)AWG] 60018008 Red 97 8.1

387FTD403 910245 4 Pair 0.63mm [22(1)AWG] 60018010 Red 150 10.4

387FTD403W - 4 Pair 0.63mm [22(1)AWG] 60044019 White 150 10.4

O/D

mm

Firetuf Coax

CONSTRUCTION

1/0.65mm solid plain copper conductor, PE/silicone rubber composite

dielectric, woven glass tape, two plain copper wire braids, Low Smoke

Halogen Free (LSHF) sheath – red

FSC Part No.

Draka

Part No.

Type

Draka Part

No. 2

Sheath

Colour

Weight

kg/km

387FTD5903 660096 75Ohm Coax 1/0.65mm 60017668 Red 110 9.1

YFTCBC1# - BNC Connector - - - -

YTC10 - BNC Crimp tool - - - -

Due to the unique size of Firetuf Coax, special BNC connectors have been designed as standard types do not fit.

O/D

mm

www.fscables.com | sales@fscables.com


Prysmian FP100

57

FP100 Single Core Enhanced Circuit Integrity

Designed for fixed installations where circuit integrity is critical in the event of a fire. The Low Smoke Halogen Free

(LSHF) insulation also ensure minimal fumes and smoke are given off providing safety for both personnel and property.

Maximum fire performance requires installation in either metal conduit or trunking.

CONSTRUCTION

Stranded plain copper conductor to BS EN

60228 Class 2, mica glass tape, cross linked

LSHF insulation.

TECHNICAL INFORMATION

Voltage Rating:

Temperature Rating:

Minimum Bending

Radius:

0.6/1kV

-25°C to +90°C

Up to 8mm diameter = 4 x cable O/D

Above 9mm diameter = 6 x cable O/D

Flame Retardant: IEC/BS EN 60332-1-2

Smoke Emission: IEC/BS EN 61034-2

Halogen Emission:

Fire Resistant:

LPCB Approved

IEC/BS EN 50267-2-1 &

IEC/BS EN 60754-1&2

IEC 60331-21, BS 6387 Categories

CWZ (when applied to a single cable

appropriately protected in steel

conduit)

3871600199

Part No. Size mm 2 Weight kg/km Nominal O/D mm

Conductor Res.

@ 20°C Ohms/km

3871501xx 1.5 26 3.9 12.1

3872501xx 2.5 38 4.6 7.41

3874001xx 4.0 54 5.0 4.61

3876001xx 6.0 75 5.5 3.08

38710001xx 10 130 7.5 1.83

38716001xx 16 185 8.2 1.15

38725001xx 25 275 9.7 0.727

38735001xx 35 360 10.5 0.524

38750001xx 50 490 12.2 0.387

38770001xx 70 700 14.1 0.268

38795001xx 95 960 15.9 0.193

38712001xx 120 1190 17.5 0.153

38715001xx 150 1510 19.4 0.124

38718501xx 185 1840 21.8 0.0991

38724001xx 240 2350 25.2 0.0754

38730001xx 300 3070 27.3 0.0601

387250101

To show the colour required please replace xx in the part number with:

00 Black

01 Blue

02 Brown

03 Red

04 White

05 Grey

99 Green/Yellow

We are also able to offer Draka FT L-Sifer on short lead times, please call us to discuss your requirements.

Tel: 01727 840 841

FIRE & SECURITY


58

Prysmian FP200 Gold

Prysmian FP200 Gold

It is now recognised that in some buildings the continued functioning or circuit integrity of some cables is essential

in providing sufficient time for evacuation. The requirements divide ‘soft skin’ cables into 2 groups, Standard and

Enhanced.

The ‘Standard’ cables on this page are stocked in Red for alarm systems and White for emergency lighting feeds.

Stocked in 100m, 200m and 500m reels.

Easy to strip and dress the FP200 gold is deservedly market leader.

38701502FPGR

CONSTRUCTION

Solid (1.5 - 2.5mm²) or stranded (4.0mm²) plain annealed copper conductor, high performance damage

resistant Insudite insulation, bonded laminated aluminium tape screen in contact with tinned copper CPC,

thermoplastic LSHF Sheath.

TECHNICAL INFORMATION

Fire Resistant: BS7629-1, Standard 60

BS EN 50200 PH30, PH60, PH120 & ANNEX E

BS 6387 C, W & Z

BS 5839-1, 6, 8 & 9

Flame Retardant: IEC/BS EN 60332-1-2

Halogen Free:

IEC/BS EN 60754-1&2

Low Smoke: IEC/BS EN 61034-2

London Underground ID: 575

LPCB & BASEC Approved

Part No. No. of Cores Size mm 2 Sheath

Colour

Weight

kg/km

O/D

mm

38701502FPGR 2 + E 1.5 Red 90 7.9

38701503FPGR 3 + E 1.5 Red 115 8.3

38701504FPGR 4 + E 1.5 Red 150 10.0

38702502FPGR 2 + E 2.5 Red 140 9.5

38702503FPGR 3 + E 2.5 Red 180 10.5

38702504FPGR 4 + E 2.5 Red 225 12.0

38704002FPGR 2 + E 4.0 Red 205 12.0

38701502FPGW 2 + E 1.5 White 90 7.9

38701503FPGW 3 + E 1.5 White 115 8.3

38701504FPGW 4 + E 1.5 White 150 10.0

38702502FPGW 2 + E 2.5 White 140 9.5

38702504FPGW 4 + E 2.5 White 225 12.0

Popular sizes stocked in 100m, 200m and 500m drums, longer lengths to order.

www.fscables.com | sales@fscables.com


Draka FT30 Saffire

59

FT30 Saffire

Designed and manufactured to BS 7629-1, this Draka fire resistant cable is ideal for fire alarms and emergency lighting in

low risk applications.

Quick to strip and easy to install, FT30 saffire is a great alternative to FP200 Gold.

CONSTRUCTION

Solid (1.5 - 2.5mm²) or stranded (4.0mm²) plain annealed copper conductor, tough durolate insulation,

aluminium/polyester laminated tape screen in contact with tinned copper CPC, thermoplastic LSHF Sheath.

38701504FTR

TECHNICAL INFORMATION

Fire Resistant:

BS7629-1

BS EN 50200 PH30, PH60, PH120 & ANNEX E

BS 6387 C, W & Z

BS 5839-1:2013 Standard

Flame Retardant: IEC/BS EN 60332-1-2

IEC/BS EN 60332-3-24

Halogen Free: IEC/BS EN 50267-2-1

Low Smoke: IEC/BS EN 61034-2

LPCB & BASEC Approved

Part No. No. of Cores Size mm 2 Sheath

Colour

Weight

kg/km

O/D

mm

38701502FTR 2 + E 1.5 Red 95 8.1

38701503FTR 3 + E 1.5 Red 120 8.4

38701504FTR 4 + E 1.5 Red 145 10.0

38702502FTR 2 + E 2.5 Red 140 9.5

38702503FTR 3 + E 2.5 Red 180 10.4

38702504FTR 4 + E 2.5 Red 225 11.9

38704002FTR 2 + E 4.0 Red 195 11.6

38701502FTW 2 + E 1.5 White 95 8.1

38701503FTW 3 + E 1.5 White 120 8.4

38701504FTW 4 + E 1.5 White 145 10.0

38702502FTW 2 + E 2.5 White 140 9.5

38702504FTW 4 + E 2.5 White 225 11.9

Popular sizes stocked in 100m, 200m and 500m drums longer lengths to order.

Tel: 01727 840 841

FIRE & SECURITY


60

Prysmian FP Plus

Prysmian FP Plus

Prysmian FP Plus is the market leader within the fire alarm sector for good reasons. Prysmian lead the way in fire cable

safety and design.

The ‘enhanced’ versions shown below are suitable for installation where evacuation may be delayed, for example in

hospitals or high-rise buildings without sprinklers. The ‘enhanced’ group of cables offer a viable alternative to MICC

(Mineral Insulated Copper Clad) in many applications with the benefit of faster installation and easier routing.

387E01504FPR

CONSTRUCTION

Solid (1.5 - 2.5mm²) or stranded (4.0mm²) plain annealed copper conductor, high performance damage resistant

Insudite insulation (Mica Tape included in 2+E 4mm² and all 3 & 4 core cables), bonded laminated aluminium

tape screen in contact with tinned copper CPC, thermoplastic LSHF Sheath.

TECHNICAL INFORMATION

Fire Resistant: BS7629-1, Enhanced 120

BS EN 50200 PH30, PH60, PH120

BS 6387 CWZ

BS 5839-1, 6, 8 & 9 ‘Enhanced’

BS 5266-1 ‘Enhanced’

BS 8434-2 ‘Enhanced’

Flame Retardant: IEC/BS EN 60332-1-2

Halogen Free: IEC/BS EN 50267-2-1

Low Smoke: IEC/BS EN 61034-2

London Underground ID:

LPCB & BASEC Approved

3935 (all 1.5 & 2.5mm² cables)

Part No. No. of Cores Size mm 2 Sheath

Colour

Weight

kg/km

O/D

mm

387E01502FPR 2 + E 1.5 Red 115 9.2

387E01503FPR 3 + E 1.5 Red 175 11.7

387E01504FPR 4 + E 1.5 Red 210 12.5

387E02502FPR 2 + E 2.5 Red 180 11.5

387E02503FPR 3 + E 2.5 Red 230 12.7

387E02504FPR 4 + E 2.5 Red 270 13.5

387E04002FPR 2 + E 4.0 Red 235 12.2

387E01502FPW 2 + E 1.5 White 115 9.2

387E01503FPW 3 + E 1.5 White 175 11.7

387E01504FPW 4 + E 1.5 White 210 12.5

387E02502FPW 2 + E 2.5 White 180 11.5

387E02504FPW 4 + E 2.5 White 270 13.5

Popular sizes stocked in 100m, 200m and 500m drums, longer lengths to order.

www.fscables.com | sales@fscables.com


Draka FT120

61

FT120

Firetuf FT120 is the Draka enhanced fire resistant cable. Ideal for fire alarm systems, emergency lighting, critical circuits

and emergency audio circuits.

With London Underground approval, you can be confident this is a high performing fire safety cable.

CONSTRUCTION

Solid (1.5 - 2.5mm²) or stranded (4.0mm²) plain annealed copper conductor, high performance silicone rubber

insulation, glass fibre tape, aluminium/polyester tape screen in contact with tinned copper CPC, thermoplastic

LSHF Sheath.

387E01502FTR

TECHNICAL INFORMATION

Fire Resistant: BS7629-1, Enhanced 120

BS EN 50200 PH30, PH60, PH120

BS 6387 C, W & Z

BS 5839-1:2013 Clause 26.2(e) Enhanced

BS 5266-1:2011 Clause 8.2.2(b) Enhanced

BS 8434-2:2003+A2:2009

Flame Retardant: IEC/BS EN 60332-1-2

IEC/BS EN 60332-3-24

Halogen Free:

IEC/BS EN 60754-1&2

Low Smoke: IEC/BS EN 61034-2

London Underground ID: 422

LPCB & BASEC Approved

Part No. No. of Cores Size mm 2 Sheath

Colour

Weight

kg/km

O/D

mm

387E01502FTR 2 + E 1.5 Red 125 8.9

387E01503FTR 3 + E 1.5 Red 145 9.2

387E01504FTR 4 + E 1.5 Red 170 10.1

387E02502FTR 2 + E 2.5 Red 185 10.4

387E02503FTR 3 + E 2.5 Red 215 11.0

387E02504FTR 4 + E 2.5 Red 255 12.0

387E04002FTR 2 + E 4.0 Red 255 12.2

387E01502FTW 2 + E 1.5 White 125 8.9

387E01503FTW 3 + E 1.5 White 145 9.2

387E01504FTW 4 + E 1.5 White 170 10.1

387E02502FTW 2 + E 2.5 White 185 10.4

387E02504FTW 4 + E 2.5 White 255 12.0

Popular sizes stocked in 100m, 200m and 500m drums, longer lengths to order.

Tel: 01727 840 841

FIRE & SECURITY


62

Prysmian FP600S

Prysmian FP600S Circuit Integrity Cable

FP 600S is the ultimate fire resistant, armoured cable for critical circuits, enabling them to continue working in the event

of a fire. Essential for equipment associated with fire fighting or safe evacuation such as ventilation, fire curtains &

emergency lighting. FP 600S has been developed to meet the highest level of fire resistance for this cable type.

FP600S is Low Smoke Halogen Free (LSHF) throughout and flame retardant, meaning it will not contribute to the hazard

of the fire by either spreading it or creating toxic fumes that are so damaging to life and equipment.

38600403

CONSTRUCTION

Plain annealed class 2 copper conductor, mica glass fire tape, 90°C XLPE insulation, LSHF bedding, galvanised

steel wire armour, LSHF black Sheath.

TECHNICAL INFORMATION

Fire Resistance:

Part No.

BS 7846 F120

BS 8491 120 Minute

IEC/BS EN 60332-3-24

BS 8519 Category 1, 2, 3 power

Fire Retardant: IEC/BS EN 60332-1-2

Temperature

Range:

-25°C to +90°C

Cores x

mm 2

Weight

kg/km

O/D

mm

38600402 2 x 4 800 21.0

38600403 3 x 4 910 22.0

38600404 4 x 4 860 21.0

38600405 5 x 4 1050 24.0

38600602 2 x 6 850 21.0

38600603 3 x 6 860 21.0

38600604 4 x 6 1000 23.0

38600605 5 x 6 1150 24.0

38601002 2 x 10 1100 23.0

38601003 3 x 10 1200 25.0

38601004 4 x 10 1400 26.0

38601005 5 x 10 1650 29.0

38601602 2 x 16 1250 25.0

38601603 3 x 16 1400 26.0

38601604 4 x 16 1650 28.0

38601605 5 x 16 2100 32.0

38602502 2 x 25 1550 27.0

38602503 3 x 25 2000 30.0

38602504 4 x 25 2400 33.0

38602505 5 x 25 2800 35.0

Voltage: 600/1000V

Halogen Free:

Part No.

IEC/BS EN 60754-1&2

Low Smoke: IEC/BS EN 61034-2

London

Underground:

LPCB & BASEC Approved*

S1085 Approved Products

Register

Cores x

mm 2

Weight

kg/km

O/D

mm

38603502 2 x 35 2100 31.0

38603503 3 x 35 2500 33.0

38603504 4 x 35 3000 36.0

38603505 5 x 35 3300 39.0

38605002 2 x 50 2100 30.0

38605003 3 x 50 3400 33.0

38605004 4 x 50 3300 37.0

38607002 2 x 70 2600 33.0

38607003 3 x 70 3350 36.0

38607004 4 x 70 4500 41.0

38609502 2 x 95 3400 36.0

38609503 3 x 95 4600 41.0

38609504 4 x 95 5700 45.0

38612002 2 x 120 4100 39.0

38612003 3 x 120 5500 44.0

38612004 4 x 120 7300 50.0

Other sizes and core configurations are available on request, please call to check availability.

We are also able to offer Draka FTP120 on short lead times.

*5 core cables are not LPCB approved

www.fscables.com | sales@fscables.com


Access Control

63

Access Control

Specifically designed for proprietary access control systems, these cables are widely used in public buildings including

hospitals, government and local authority offices as well as commercial and retail organisations where security and safety

are important.

The Low Smoke Halogen Free (LSHF) versions ensure minimum risk in the event of fire to both property and personnel.

Composite Access Control - Purple Pipe 3993P9CHP

CONSTRUCTION

Pair 1: 1 twisted pair 20(7)AWG tinned copper strands, foam PE insulation, 20(7)AWG tinned copper

drain wire, aluminium/polyester foil. Colour code: Black/Green.

Pairs 2 & 3: 2 twisted pairs 22(7)AWG tinned copper strands, foam PE insulation, 22(7)AWG tinned copper

drain wire, each individual pair aluminium/polyester foil screened. Pair colour code: Black/Red &

Black/White.

Cores: 9 single cores 22(7)AWG tinned copper wire strands, solid polyethylene insulation.

Colour code: Black, White, Red, Green, Brown, Blue, Orange, Yellow, Purple.

Overall Screen: aluminium/polyester foil, 22(7)AWG tinned copper drain wire.

Sheath: LSHF, Purple.

3993P9CHP

Part No.

Alt. to

Belden

No. of

Pairs

AWG

Screen

Type

Weight

kg/km

3993P9CHP - - - - 114 9.5

O/D

mm

Access Control

Part No.

Alt. to

Belden

No. of

Pairs

AWG

Screen

Type

Weight

kg/km

O/D

mm

Protocol

2202PIFRL 8723 2 22 Individual foils 32 4.2 Traditional security

2202PIFRH 8723NH 2 22 Individual foils 32 4.2 Traditional security

2203PIFRL 8777 3 22 Individual foils 70 6.9 Traditional security

2203PIFRH 8777NH 3 22 Individual foils 70 6.9 Traditional security

2402POHPL 9842 2 24 O/A foil & braid 95 8.7 RS-485

2402POHPH 9842NH 2 24 O/A foil & braid 95 8.7 RS-485

2802PODGH 8132NH 2 28 O/A foil & braid 45 5.6 RS-485

2803PODGH 8133NH 3 28 O/A foil & braid 52 6.8 RS-485

2202PIFRL

Access control cables are also available from stock in PVC/LSF versions either in standard pack sizes or cut to length from

bulk drums and shown at the front section of this book, or call to discuss your requirements.

Low Smoke Halogen Free

CPR-Compliant Options Available

Tel: 01727 840 841

FIRE & SECURITY


64

Alarm Cables

Unscreened Burglar Alarm Cables

Designed for connecting detectors, sensors, keypads and control panels, Alarm cables are the “bread and butter” of

the security industry. Due to the unregulated nature of the cables coming onto the market a new standard has been

introduced. BS 4737-3.30 2015 sets out the construction of the cables and the maximum resistance of the conductors.

The FSC range of unscreened alarm cables are manufactured with a rip cord for easy stripping, available in PVC, LSHF or

a black PE sheathed duct grade version. Packed on 100m, 200m, and 500m reels.

39800208WH

CONSTRUCTION

Type 2 PVC: Tinned copper wire strands, PVC/LSF

insulation, rip cord, PVC/LSF sheath

Type 1 LSHF: Tinned copper wire strands, Low Smoke

Halogen Free (LSHF) insulation, rip cord,

LSHF sheath

Type 2 Duct: Tinned copper wire strands, PVC

insulation, rip cord, PVC inner sheath,

black LDPE outer sheath

TECHNICAL INFORMATION

Temperature Rating:

Conductor Size:

Max Conductor

Resistance:

Max Working Voltage:

Max Current:

0°C to +70°C

0.22mm 2 (24AWG)

100 Ohm/Km

50V

1 amp per core

Standards: BS 4737-3.30 2015

FS Cables do not sell the low grade, high resistance aluminium version to type 3.

PVC/LSF Unscreened Alarm Cable

Part No.

Cores

Weight

kg/km

O/D

mm

39800204WL 4 18 3.4

39800206WL 6 25 4.0

39800208WL 8 30 4.3

39800212WL 12 37 5.5

Duct Grade Unscreened Alarm Cable

Part No.

Cores

Weight

kg/km

O/D

mm

39200206D 6 52 7.2

39200208D 8 56 8.1

39200212D 12 68 8.9

LSHF Unscreened Alarm Cable

Part No.

Cores

Weight

kg/km

O/D

mm

39800204WH 4 18 3.4

39800206WH 6 25 4.0

39800208WH 8 30 4.3

39800212WH 12 37 5.5

Armoured Unscreened Alarm Cable

Part No.

Cores

Weight

kg/km

O/D

mm

39200206A 6 328 10.9

39200208A 8 342 11.8

39200212A 12 356 12.6

Core Colour Code:

4-core: Red, Blue, Yellow, Black

6-core: Red, Blue, Yellow, Black, White, Green

8-core: Red, Blue, Yellow, Black, White, Green, Orange*, Brown

12-core: Red, Blue, Yellow, Black, White, Green, Orange, Brown, Grey, Pink, Violet, Turquoise

*On duct grade and armoured cables core 7 is violet.

Brown or black PVC alarm cable also available.

Standard packing 100m, 200m & 500m spools.

Low Smoke Halogen Free Duct Grade Amoured CPR-Compliant Options Available

www.fscables.com | sales@fscables.com


Alarm Cables

65

Screened Burglar Alarm Cables

The screened versions of the FSC range of Alarm cables are used where the environment is electrically noisy, this may be

where the alarm cables will be crossing or near to mains or control cables or where equipment or machinery is emitting

large amounts of Electro Magnetic Radiation (EMR) Stocked in three types, PVC, LSHF and duct grade meeting BS 4737-

3.30 2015 you can be sure quality hasn’t been compromised.

CONSTRUCTION

Type 2 PVC: Tinned copper wire strands, PVC/LSF

insulation, aluminium/polyester foil,

stranded tinned copper drain wire, rip

cord, PVC/LSF sheath

Type 1 LSHF: Tinned copper wire strands, Low Smoke

Halogen Free (LSHF) insulation, rip cord,

LSHF sheath

Type 2 Duct: Tinned copper wire strands, PVC

insulation, aluminium/polyester foil,

stranded tinned copper drain wire, rip

cord, PVC inner sheath, black LDPE outer

sheath

TECHNICAL INFORMATION

Temperature Rating:

Conductor Size:

Max Conductor

Resistance:

Max Working Voltage:

Max Current:

0°C to +70°C

0.22mm 2 (24AWG)

100 Ohm/Km

50V

1 amp per core

Standards: BS 4737-3.30 2015

39900208WH

FS Cables do not sell the low grade, high resistance aluminium version to type 3.

PVC/LSF Foil Screened Alarm Cable

Part No.

Cores

Weight

kg/km

O/D

mm

39900204WL 4 24 3.7

39900206WL 6 28 4.3

39900208WL 8 34 4.6

39900212WL 12 47 6.2

Duct Grade Screened Alarm Cable

Part No.

Cores

Weight

kg/km

O/D

mm

39400206D 6 53 7.5

39400208D 8 58 8.6

39400212D 12 72 9.6

LSHF Foil Screened Alarm Cable

Part No.

Cores

Weight

kg/km

O/D

mm

39900204WH 4 24 3.7

39900206WH 6 28 4.3

39900208WH 8 34 4.6

39900212WH 12 47 6.2

Armoured Screened Alarm Cable

Part No.

Cores

Weight

kg/km

O/D

mm

39400206A 6 342 11.2

39400208A 8 358 12.3

39400212A 12 372 13.3

Core Colour Code:

4-core: Red, Blue, Yellow, Black

6-core: Red, Blue, Yellow, Black, White, Green

8-core: Red, Blue, Yellow, Black, White, Green, Orange*, Brown

12-core: Red, Blue, Yellow, Black, White, Green, Orange, Brown, Grey, Pink, Violet, Turquoise

*On duct grade and armoured cables core 7 is violet.

Brown or black PVC alarm cable also available.

Standard packing 100m, 200m & 500m spools.

Low Smoke Halogen Free Duct Grade Amoured

CPR-Compliant Options Available

Tel: 01727 840 841

FIRE & SECURITY


66

Outdoor Data & Coaxial

2403POFYD

Outdoor Data & Coaxial

With the increased use of data and signal cables in security, BMS, access control and monitoring

applications the need for suitable cables to run outside or through ducts has grown. FSC offer an

over-sheathing service for any stock product for quantities as low as 100m.

The products listed below are all stock items and have heavy additional black UV resistant

polyethylene sheaths similar to those used on external telephone cables you see strung between

poles or run through ducts.

Outdoor Data Cables

Part No.

Alt. to Belden

Number of

Pairs & AWG

Weight

kg/km

O/D

mm

Colour

1801POFPD 8760 1 x 2 x 18 48 8.1 Black

2202PIFRD 8723 2 x 2 x 22 50 6.2 Black

2203PIFRD 8777 3 x 2 x 22 96 8.6 Black

2401POFYD 9501 1 x 2 x 24 44 6.4 Black

2402POFYD 9502 2 x 2 x 24 60 7.9 Black

2403POFYD 9503 3 x 2 x 24 66 8.3 Black

2404POFYD 9504 4 x 2 x 24 72 9.2 Black

2406POFYD 9506 6 x 2 x 24 93 9.6 Black

2402PIFFD 9729 2 x 2 x 24 79 9.6 Black

2401POHPD 9841 1 x 2 x 24 92 8.7 Black

2402POHPD 9842 2 x 2 x 24 118 11.5 Black

C5ED

Exterior Grade Structured Wiring

Part No.

Description

Number of

Pairs & AWG

Weight

kg/km

O/D

mm

Colour

C5ED Cat 5E UTP Duct Grade 4 x 2 x 24 67 8.6 Black

C5EFD Cat 5E FTP Duct Grade 4 x 2 x 24 68 8.8 Black

C525D Cat 5 UTP Duct Grade 25 x 2 x 24 278 17.0 Black

C6D Cat 6 UTP Duct Grade 4 x 2 x 23 86 9.9 Black

C6FD Cat 6 FTP Duct Grade 4 x 2 x 23 98 10.0 Black

C6GFFHD Cat 6A F/FTP Duct Grade 4 x 2 x 23 102 10.0 Black

C7HRD Cat 7 S/FTP Duct Grade 4 x 2 x 23 105 10.2 Black

Outdoor Coaxial Cables

Part No.

Description

Weight

kg/km

O/D

mm

Colour

390011D RG11 A/U Duct Grade 194 12.1 Black

390058D RG58 C/U Duct Grade 59 6.5 Black

390059D RG59 B/U Duct Grade 76 7.9 Black

391070D URM 70 Duct Grade 72 8.0 Black

392100D TV 100 Duct Grade 30 7.0 Black

392125D TV 125 Duct Grade 52 9.5 Black

392167D TV 167 Duct Grade 110 11.7 Black

Duct Grade

CPR-Compliant Options Available

www.fscables.com | sales@fscables.com


Armoured Data & Coaxial

67

Armoured Data & Coaxial

390059A

Where data or signal cables may be exposed to mechanical damage, additional protection of

galvanised steel wire armour or SWA is ideal. Suitable for direct burial these cables are also popular

in applications above ground where accidental or deliberate damage may occur.

Common applications include CCTV installations in football stadiums, shopping centres and other

public areas where systems need to continue functioning despite the activities of trouble makers.

Equally important may be data or security cabling in car parks, warehouses and factories where

vehicle damage may severely compromise the operation of business.

Armoured Data Cables

Part No.

Alt. to Belden

Number of

Pairs & AWG

Weight

kg/km

O/D

mm

Colour

2202PIFRA 8723 2 x 2 x 22 210 9.5 Black

2203PIFRA 8777 3 x 2 x 22 330 13.2 Black

2402PIFFA 9729 2 x 2 x 24 176 12.5 Black

2401POHPA 9841 1 x 2 x 24 192 12.0 Black

2402POHPA 9842 2 x 2 x 24 251 15.3 Black

Armoured Structured Wiring

Part No.

Description

Number of

Pairs & AWG

Weight

kg/km

O/D

mm

Colour

C5EA Cat 5E UTP 4 x 2 x 24 239 12.6 Black

C5EFA Cat 5E FTP 4 x 2 x 24 275 12.2 Black

C525A Cat 5E UTP 25 x 2 x 24 598 21.6 Black

C6A Cat 6 UTP 4 x 2 x 23 309 14.2 Black

C6FA Cat 6 FTP 4 x 2 x 23 315 14.5 Black

2202PIFRA

Armoured Coaxial Cables

Part No.

Description

Weight

kg/km

O/D

mm

Colour

390011A RG11 A/U 380 15.7 Black

390059A RG59 B/U 250 10.3 Black

390062A RG62 A/U 210 10.4 Black

SWA

CPR-Compliant Options Available

Tel: 01727 840 841

FIRE & SECURITY


68

Outdoor Control

10001504D

Outdoor Control

The FSC range of duct grade YY cable is suitable to be either run through ducts or clipped to

buildings or other exposed areas when an armoured cable is not required. The cables are rated

to 0.6/1kV and have XLPE insulation, a water blocking gel tape, a PVC bedding and a UV stable

black polyethylene sheath which also gives additional mechanical strength and water resistance.

The colour code is the conventional brown, blue, green/yellow (on three core) for simple wiring.

Despite their toughness they remain remarkably flexible.

The gel tape remains dry until exposed to water when it swells to form a water barrier. This

prevents any mess during termination normally associated with petroleum jelly filled cables.

The cable is stocked on bulk drums and can be cut to length to reduce your wastage and save

time. If these cables require added protection we can also armour them with MOQs as low as a

hundred metres. Please see page 206 for more details or call us with your specific requirements.

Tough and flexible, they can also be used as a direct alternative to the old Draka Hi-Tuf cables.

CONSTRUCTION

Plain copper wire conductors to IEC/BS EN 60228

class 5, XLPE colour coded insulation, water

blocking tape, bedding compound of PVC, UV

resistant polyethylene sheath.

TECHNICAL INFORMATION

Voltage Rating:

0.6/1kV

Conductor Stranding: IEC/BS EN 60228 class 5

Temperature Rating:

Bending Radius:

Static -20°C to +80°C

Flexing -5°C to +70°C

10 x overall diameter

10002503D

Part No.

Cores x

mm 2

Colour Code

Weight

kg/km

O/D

mm

10001002D 2 x 1.0 Blue, Brown 83 8.8

10001003D 3 x 1.0 Blue, Brown, Green/Yellow 103 9.2

10001004D 4 x 1.0 Brown, Black, Grey, Green/Yellow 121 9.6

10001005D 5 x 1.0 Blue, Brown, Black, Grey, Green/Yellow 149 10.7

10001502D 2 x 1.5 Blue, Brown 118 9.7

10001503D 3 x 1.5 Blue, Brown, Green/Yellow 135 10.4

10001504D 4 x 1.5 Brown, Black, Grey, Green/Yellow 152 11.4

10001505D 5 x 1.5 Blue, Brown, Black, Grey, Green/Yellow 201 12.3

10002502D 2 x 2.5 Blue, Brown 152 11.0

10002503D 3 x 2.5 Blue, Brown, Green/Yellow 188 11.8

10002504D 4 x 2.5 Brown, Black, Grey, Green/Yellow 225 12.8

10002505D 5 x 2.5 Blue, Brown, Black, Grey, Green/Yellow 304 14.2

10004003D 3 x 4.0 Blue, Brown, Green/Yellow 260 13.5

Duct Grade

www.fscables.com | sales@fscables.com


Composite Coaxial & Door Entry

69

Composite Coaxial & Door Entry

39005922H

To meet the increasing demands for camera cables containing a coax with power and control cores

for Pan, Tilt, Zoom (PTZ) or audio we are now stocking a variety of options.

These can either be within one circular jacket for easy glanding or in a shotgun style with a web

between the individual elements for branching off at termination or glanding points.

Designed to meet the need of the installer of proprietary door entry systems, door entry cables

cover video, voice and door release. Stocked on bulk drums, cutting to length is offered to reduce

your wastage and cut costs. Armoured and duct grade versions are also available.

Composite Coaxial

Part No.

Coax

Power

Cores

Signal

Cores

Construction

O/D

mm

Colour

39005922D RG59 B/U 2 x 1.5mm² 2 x 0.22mm² Circular Duct 13.9 Black

39005922H RG59 B/U 2 x 1.5mm² 2 x 0.22mm² Circular LSHF 11.5 Black

3900592L RG59 2 x 0.75mm² - Shotgun LSF 6.1 x 12.0 Black

3900592D RG59 2 x 0.75mm² - Circular Duct 6.1 x 12.0 Black

3910702L URM70 2 x 0.75mm² - Shotgun LSF 5.8 x 11.2 White

Bus Wiring & Door Release

Part No.

Alt. to

Belden

No. of

Pairs

AWG

Screen Type

Weight

kg/km

O/D

mm

Protocol

1601PUYL 8471 1 16(19) Unscreened 56 7.0 Echelon

1601PUYH 8471NH 1 16(19) Unscreened 56 7.0 Echelon

1601POFPL 8719 1 16(19) Over foil 84 7.9 -

1601POFPH 8719 1 16(19) Over foil 84 7.9 -

1806COFRH

Honeywell Door Entry Cable

To meet the needs of installers of Honeywell equipment, FS Cables now stock a new door entry

cable.

With an overall screen and 6 cores of 18(7) AWG, this PVC data cable is for use on card reader

systems, connecting the reader where a card is swiped to the processor. As an alternative to Belden

5304FE, it is compatible with Win-PAK ® , Nstar and Pro-Watch ® software and N1000, NetAXS panels,

Pro2200 and PW6000 hardware panels. It can also be used on any card reader system using the

same Wiegand format.

Part No.

Alt. to

Belden

No. of

Cores

AWG

Sheath

Material

Colour

Weight

kg/km

1806COFRL 5304FE 6 18 PVC/LSF Blue 63 5.8

1806COFRH 5304FE 6 18 LSHF Blue 63 5.8

O/D

mm

1806COFRL Honeywell part number: 2216

1806COFRH Honeywell part number: 3216

Low Smoke Halogen Free

Duct Grade

Tel: 01727 840 841

FIRE & SECURITY


3500

PRODUCT LINES HELD IN

OUR 67,000sqft

WAREHOUSE FOR

NEXT DAY DELIVERY


71

Fibre Optic

Introduction

Fibre Optic cables offer significant advantages over

copper data cables in the right applications.

The majority of the FSC range of Fibre cables are

manufactured by Draka, some using BendBright

technology to ensure trouble-free operation even

where installation and routing are difficult.

Fibre optic cables fall into two categories,

singlemode (OS1 & OS2) for long distances and

multimode (OM1, OM2, OM3 & OM4) for more

localised data distribution. Cables can be supplied

with various numbers of fibres, loose tube or tight

buffered construction, with or without armours.

Compared to copper data cables, fibre is relatively

low cost, lightweight and has small overall

diameters for the number of fibres. It is also immune

to the effects of electromagnetic radiation, so they

can be run alongside power cables or in electrically

noisy environments.

The cost of terminations or connectors and the

electronics at either end can push the system cost

up but fibre offers incredible bandwidth and is able

to carry vast amounts of error-free information over

very small cables. It is the natural choice in an everincreasing

number of applications.

Contents

OS2 Loose Tube Fibre Optic 72

OS2 Tight Buffered Fibre Optic 73

OM1 Loose Tube Fibre Optic 74

OM1 Tight Buffered Fibre Optic 75

OM3 Loose Tube Fibre Optic 76

OM3 Tight Buffered Fibre Optic 77

OM4 Loose Tube Fibre Optic 78

OM4 Tight Buffered Fibre Optic 79

Firetuf Fire Resistant Fibre Optic

Unarmoured

Firetuf Fire Resistant Fibre Optic

Armoured

80

81

Duplex Fibre Optic 82

Pre Terminated Fibre Optic 83

In addition to the internal/external and armoured

options, FSC also stocks the Draka Firetuf range of

Fibre Optic cables. Designed to carry on operating

in the event of a fire, in a similar test to the copper

fire alarm cables, the Draka Firetuf Optical cables

are ideal for critical data circuits. CCTV, evacuation

monitoring and where data needs to be transferred

in emergency situations are ideal applications. Fire

safety is further enhanced by the limited smoke

generation, Halogen free properties and limited fire

spread, making it ideal for use in transport systems,

data centres and hospitals.

Tel: 01727 840 841

FIBRE OPTIC


72

OS2 Loose Tube Fibre Singlemode

OS2 9/125µm Loose Tube Fibre Optic Cable Unarmoured & Armoured Int/Ext

Singlemode Loose Tube fibre (OS2) aimed at LAN and WAN backbones, telecoms, as well as Fibre to the Building (FTTB)

and Fibre to the Home (FTTH). Ideal for internal and external applications the tough sheathing compound is LSHF and UV

resistant. Fibres are contained in a Gel filled tube to prevent moisture ingress. Designed for direct burial, the armoured

version also offers excellent rodent and mechanical protection.

FOS212LUH00

OS2 Singlemode 9/125µm Loose Tube Fibre Optic Unarmoured - U-DQ(ZN)BH

CONSTRUCTION

Single jelly filled central tube surrounded by waterblocked E-Glass fibre elements, LSHF UV resistant sheath to IEC

50290-2-27.

OPTICAL FIBRE TECHNICAL INFORMATION

Fibre Type: G652D, OS2

Optical Fibre

Standards:

EN 60793-2-50 Category B.1.3

ITU-T Recommendation G.652.D and

C, B, A

EN 50173-1-2007, cat. OS2 & OS1

ISO / IEC 11801:2002, cat. OS2 & OS1

ISO / IEC 24702:2006, cat. OS2 & OS1

IEEE 802.3 - 2002 incl.802.3ae

FINISHED CABLE TECHNICAL INFORMATION

Standards:

ISO 11801 2nd Edition

EN 50173-1-2002

IEC 60794-1

Temperature Rating: Flexing -30°C to +40°C

Static -30°C to +60°C

Minimum Bend Radius: Unloaded 60mm

Loaded 100mm

Flame Retardant: IEC/BS EN 60332-1-2

Smoke Emission: IEC/BS EN 61034-2

Halogen Emission: IEC/BS EN 60754-1&2

Part No.

No. of Fibres

Sheath

Material

Sheath

Colour

Weight

kg/km

O/D

mm

FOS204LUH00 4 LSHF Black 40 6.0

FOS208LUH00 8 LSHF Black 40 6.0

FOS212LUH00 12 LSHF Black 40 6.0

FOS216LUH00 16 LSHF Black 40 6.0

FOS224LUH00 24 LSHF Black 45 6.5

OS2 Singlemode 9/125µm Loose Tube Fibre Optic Armoured - U-DQ(ZN)(SR)H

FOS212LUHC00

CONSTRUCTION

Single jelly filled central tube surrounded by waterblocked E-Glass fibre elements, corrugated steel tape armour,

LSHF UV resistant sheath to IEC 50290-2-27

OPTICAL FIBRE TECHNICAL INFORMATION

Fibre Type: G652D, OS2

Optical Fibre

Standards:

EN 60793-2-50 Category B.1.3

ITU-T Recommendation G.652.D and

C, B, A

EN 50173-1-2007, cat. OS2 & OS1

ISO / IEC 11801:2002, cat. OS2 & OS1

ISO / IEC 24702:2006, cat. OS2 & OS1

FINISHED CABLE TECHNICAL INFORMATION

Standards:

ISO 11801 2nd Edition

EN 50173-1-2002

IEC 60794-1

Temperature Rating: Flexing -40°C to +70°C

Static -40°C to +70°C

Minimum Bend Radius: 55mm

Flame Retardant: IEC/BS EN 60332-1-2

Smoke Emission: IEC/BS EN 61034-2

Halogen Emission: IEC/BS EN 60754-1&2

Part No.

No. of

Fibres

Armour

Sheath

Material

Sheath

Colour

Weight

kg/km

FOS204LUHC00 4 CST LSHF Black 75 8.5

FOS208LUHC00 8 CST LSHF Black 75 8.5

FOS212LUHC00 12 CST LSHF Black 75 8.5

FOS216LUHC00 16 CST LSHF Black 75 8.5

FOS224LUHC00 24 CST LSHF Black 85 8.5

O/D

mm

Low Smoke Halogen Free

Armoured

CPR-Compliant Options Available

www.fscables.com | sales@fscables.com


OS2 Tight Buffered Fibre Singlemode

73

OS2 9/125µm Tight Buffered Fibre Optic Cable Int/Ext

Tight buffered cables hold the Fibres in a bedding or buffering of aramid or glass yarn. This has the advantage of not

containing gel making termination easier and is ideal for indoor applications. The FSC range of OS2 Tight buffered fibre

cables are designed for LAN and WAN backbones, particularly in commercial applications such as Data Centres where it

is installed on trays or dry ducts. The cable can be run outdoors due to the tough, water resistant UV stable jacket but it

does not have the longitudinal water blocking properties of the version on page 72.

OS2 Singlemode 9/125µm Tight Buffered Fibre Optic Unarmoured - U-V(ZN)H

CONSTRUCTION

Tight buffered fibres packed along with E-glass roving strength members, LSHF UV resistant sheath to IEC

50290-2-27.

FOS208TUH00

OPTICAL FIBRE TECHNICAL INFORMATION

Fibre Type: G652D, OS2

Optical Fibre

Standards:

EN 60793-2-50 Category B.1.3

ITU-T Recommendation G.652.D and

C, B, A

EN 50173-1-2007, cat. OS2 & OS1

ISO / IEC 11801:2002, cat. OS2 & OS1

ISO / IEC 24702:2006, cat. OS2 & OS1

FINISHED CABLE TECHNICAL INFORMATION

Standards:

ISO 11801 2nd Edition

EN 50173-1-2002

IEC 60794-2

Temperature Rating: Flexing -20°C to +70°C

Static -20°C to +70°C

Minimum Bend Radius: Up to 8 fibre 50mm

12 & 16 fibre 75mm

Flame Retardant: IEC/BS EN 60332-1-2

Smoke Emission: IEC/BS EN 61034-2

Halogen Emission: IEC/BS EN 60754-1&2

Part No.

No. of Cores

Sheath

Material

Sheath

Colour

Weight

kg/km

O/D

mm

FOS204TUH00 4 LSHF Black 34 6.5

FOS208TUH00 8 LSHF Black 39 7.0

FOS212TUH00 12 LSHF Black 43 7.5

FOS216TUH00 16 LSHF Black 52 8.0

FOS224TUH00 24 LSHF Black 63 8.5

Low Smoke Halogen Free

CPR-Compliant Options Available

Tel: 01727 840 841

FIBRE OPTIC


74

OM1 Loose Tube Fibre Multimode

OM1 62.5/125µm Loose Tube Fibre Optic Cable Unarmoured & Armoured Int/Ext

OM1 loose tube, gel-filled cables are multi-mode fibre optic cables using 62.5/125µm fibre. Ideal for extending existing

OM1 installations and where low data rates are needed over short distances. OM1 Fibre has been popular for many

years but new installations are increasingly needing to carry more data where OM3 and OM4 cables are better suited.

Available in both armoured and unarmoured versions the optional corrugated steel tape armour type can be easily

routed on a tray or clipped to walls.

FOM112LUH00

OM1 Multimode 62.5/125µm Loose Tube Fibre Optic Unarmoured - U-DQ(ZN)BH

CONSTRUCTION

Single jelly filled central tube surrounded by waterblocked E-Glass fibre elements, LSHF UV resistant sheath to IEC

50290-2-27.

OPTICAL FIBRE TECHNICAL INFORMATION

Fibre Type: OM1

Optical Fibre

Standards:

EN 60793-2-10 type A1b

TIA/EIA-492 AAAA

ANSI/TIA/EIA - 568.B.3 - 2000

EN 50173-1:2007 category OM1

ISO / IEC 11801 category OM1

IEEE 802.3 - 2002 with ammendment

802.3ae - 2002

FINISHED CABLE TECHNICAL INFORMATION

Standards:

ISO 11801 2nd Edition

EN 50173-1-2002

IEC 60794-1

Temperature Rating: Flexing -30°C to +40°C

Static -30°C to +60°C

Minimum Bend Radius: Unloaded 60mm

Loaded 100mm

Flame Retardant: IEC/BS EN 60332-1-2

Smoke Emission: IEC/BS EN 61034-2

Halogen Emission: IEC/BS EN 60754-1&2

Part No.

No. of Fibres

Sheath

Material

Sheath

Colour

Weight

kg/km

O/D

mm

FOM104LUH00 4 LSHF Black 40 6.0

FOM108LUH00 8 LSHF Black 40 6.0

FOM112LUH00 12 LSHF Black 40 6.0

FOM116LUH00 16 LSHF Black 40 6.0

FOM124LUH00 24 LSHF Black 45 6.5

OM1 Multimode 62.5/125µm Loose Tube Fibre Optic Armoured - U-DQ(ZN)(SR)H

FOM112LUHC00

CONSTRUCTION

Single jelly filled central tube surrounded by waterblocked E-Glass fibre elements, corrugated steel tape armour,

LSHF UV resistant sheath to IEC 50290-2-27.

OPTICAL FIBRE TECHNICAL INFORMATION

Fibre Type: OM1

Optical Fibre

Standards:

EN 60793-2-10 type A1b

TIA/EIA-492 AAAA

ANSI/TIA/EIA - 568.B.3 - 2000

EN 50173-1:2007 category OM1

ISO / IEC 11801 category OM1

IEEE 802.3 - 2002 with ammendment

802.3ae - 2002

FINISHED CABLE TECHNICAL INFORMATION

Standards:

ISO 11801 2nd Edition

EN 50173-1-2002

IEC 60794-1

Temperature Rating: Flexing -40°C to +70°C

Static -40°C to +70°C

Minimum Bend Radius: 55mm

Flame Retardant: IEC/BS EN 60332-1-2

Smoke Emission: IEC/BS EN 61034-2

Halogen Emission: IEC/BS EN 60754-1&2

Part No.

No. of

Fibres

Armour

Sheath

Material

Sheath

Colour

Weight

kg/km

FOM104LUHC00 4 CST LSHF Black 75 8.5

FOM108LUHC00 8 CST LSHF Black 75 8.5

FOM112LUHC00 12 CST LSHF Black 75 8.5

FOM116LUHC00 16 CST LSHF Black 75 8.5

FOM124LUHC00 24 CST LSHF Black 85 8.5

O/D

mm

Low Smoke Halogen Free

Armoured

CPR-Compliant Options Available

www.fscables.com | sales@fscables.com


OM1 Tight Buffered Fibre Multimode

75

OM1 62.5/125µm Tight Buffered Fibre Optic Cable Int/Ext

OM1 62.5/125µm tight buffered fibre optic cables lay up, the colour coded fibres surrounded by E-Glass to give it

good tensile strength and protection against crush. Ideally suited to indoor applications the cable also has a Low Smoke

Halogen Free (LSHF), flame retardant jacket that is UV resistant so can be used outdoors as well.

OM1 Multimode 62.5/125µm Tight Buffered Fibre Optic Unarmoured - U-V(ZN)H

CONSTRUCTION

Tight buffered fibres packed along with E-glass roving strength members, LSHF UV resistant sheath to IEC

50290-2-27.

FOM108TUH00

OPTICAL FIBRE TECHNICAL INFORMATION

Fibre Type: OM1

Optical Fibre

Standards:

EN 60793-2-10 type A1b

TIA/EIA-492 AAAA

ANSI/TIA/EIA - 568.B.3 - 2000

EN 50173-1:2007 category OM1

ISO / IEC 11801 category OM1

IEEE 802.3 - 2002 with ammendment

802.3ae - 2002

FINISHED CABLE TECHNICAL INFORMATION

Standards:

ISO 11801 2nd Edition

EN 50173-1-2002

IEC 60794-1

Temperature Rating: Flexing -20°C to +70°C

Static -20°C to +70°C

Minimum Bend Radius: Up to 8 fibre 50mm

12 & 16 fibre 75mm

Flame Retardant: IEC/BS EN 60332-1-2

Smoke Emission: IEC/BS EN 61034-2

Halogen Emission: IEC/BS EN 60754-1&2

Part No.

No. of Fibres

Sheath

Material

Sheath

Colour

Weight

kg/km

O/D

mm

FOM104TUH00 4 LSHF Black 34 6.5

FOM108TUH00 8 LSHF Black 39 7.0

FOM112TUH00 12 LSHF Black 43 7.5

FOM116TUH00 16 LSHF Black 52 8.0

FOM124TUH00 24 LSHF Black 63 8.5

Low Smoke Halogen Free

CPR-Compliant Options Available

Tel: 01727 840 841

FIBRE OPTIC


76

OM3 Loose Tube Fibre Multimode

OM3 50/125µm Loose Tube Fibre Optic Cable Unarmoured & Armoured Int/Ext

OM3 50/125µm fibre, also known as 10Gig fibre, is now the entry level standard for a lot of new installations where

the requirement to transfer data is classed as moderate. Using lasers as the drivers OM2 and OM3 cables can carry vast

amounts of data at either 850nm or 1300nm in some cases up to 550m. Loose tube versions are available in either

armoured or unarmoured versions and are designed for internal or external applications.

FOM312LUH00

OM3 Multimode 50/125µm Loose Tube Fibre Optic Unarmoured - U-DQ(ZN)BH

CONSTRUCTION

Single jelly filled central tube surrounded by waterblocked E-Glass fibre elements, LSHF UV resistant sheath to IEC

50290-2-27.

OPTICAL FIBRE TECHNICAL INFORMATION

Fibre Type: G651.1, OM3

Optical Fibre

Standards:

EN 60793-2-10 type A1a.2

TIA/EIA-492 AAAC

ANSI/TIA/EIA - 568.C

EN 50173-1:2007 category OM3

ISO / IEC 11801 category OM3

ITU G.651.1

ISO/IEC 24764

FINISHED CABLE TECHNICAL INFORMATION

Standards:

ISO 11801 2nd Edition

EN 50173-1-2002

IEC 60794-1

Temperature Rating: Flexing -30°C to +40°C

Static -30°C to +60°C

Minimum Bend Radius: Unloaded 60mm

Loaded 100mm

Flame Retardant: IEC/BS EN 60332-1-2

Smoke Emission: IEC/BS EN 61034-2

Halogen Emission: IEC/BS EN 60754-1&2

Part No.

No. of Fibres

Sheath

Material

Sheath

Colour

Weight

kg/km

O/D

mm

FOM304LUH00 4 LSHF Black 40 6.0

FOM308LUH00 8 LSHF Black 40 6.0

FOM312LUH00 12 LSHF Black 40 6.0

FOM316LUH00 16 LSHF Black 40 6.0

FOM324LUH00 24 LSHF Black 45 6.5

OM3 Multimode 50/125µm Loose Tube Fibre Optic Armoured - U-DQ(ZN)(SR)H

FOM312LUHC00

CONSTRUCTION

Single jelly filled central tube surrounded by waterblocked E-Glass fibre elements, corrugated steel tape armour,

LSHF UV resistant sheath to IEC 50290-2-27.

OPTICAL FIBRE TECHNICAL INFORMATION

Fibre Type: G651.1, OM3

Optical Fibre

Standards:

EN 60793-2-10 type A1a.2

TIA/EIA-492 AAAC

ANSI/TIA/EIA - 568.C

EN 50173-1:2007 category OM3

ISO / IEC 11801 category OM3

ITU G.651.1

ISO/IEC 24764

FINISHED CABLE TECHNICAL INFORMATION

Standards:

ISO 11801 2nd Edition

EN 50173-1-2002

IEC 60794-1

Temperature Rating: Flexing -40°C to +70°C

Static -40°C to +70°C

Minimum Bend Radius: 55mm

Flame Retardant: IEC/BS EN 60332-1-2

Smoke Emission: IEC/BS EN 61034-2

Halogen Emission: IEC/BS EN 60754-1&2

Part No.

No. of

Fibres

Armour

Sheath

Material

Sheath

Colour

Weight

kg/km

FOM304LUHC00 4 CST LSHF Black 75 8.5

FOM308LUHC00 8 CST LSHF Black 75 8.5

FOM312LUHC00 12 CST LSHF Black 75 8.5

FOM316LUHC00 16 CST LSHF Black 75 8.5

FOM324LUHC00 24 CST LSHF Black 85 8.5

O/D

mm

Low Smoke Halogen Free

Armoured

CPR-Compliant Options Available

www.fscables.com | sales@fscables.com


OM3 Tight Buffered Fibre Multimode

77

OM3 50/125µm Tight Buffered Fibre Optic Cable Int/Ext

Using the OM3 50/125µm fibre in a tight buffered format makes for a simple, easy installation indoors. With no messy

gel to clean up and simple fibre termination, the tight buffered OM3 fibre comes in a range of fibre counts and is

rugged enough to take on difficult routing over long distances. The UV resistant LSHF jacket also enables it to be used

outdoors or run between buildings in ducts.

OM3 Multimode 50/125µm Tight Buffered Fibre Optic Unarmoured - U-V(ZN)H

CONSTRUCTION

Tight buffered fibres packed along with E-glass roving strength members, LSHF UV resistant sheath to IEC

50290-2-27.

FOM308TUH00

OPTICAL FIBRE TECHNICAL INFORMATION

Fibre Type: G651.1, OM3

Optical Fibre

Standards:

EN 60793-2-10 type A1a.2

TIA/EIA-492 AAAC

ANSI/TIA/EIA - 568.C

EN 50173-1:2007 category OM3

ISO / IEC 11801 category OM3

ITU G.651.1

ISO/IEC 24764

FINISHED CABLE TECHNICAL INFORMATION

Standards:

ISO 11801 2nd Edition

EN 50173-1-2002

IEC 60794-1

Temperature Rating: Flexing -20°C to +70°C

Static -20°C to +70°C

Minimum Bend Radius: Up to 8 fibre 50mm

12 & 16 fibre 75mm

24 fibre 115mm

Flame Retardant: IEC/BS EN 60332-1-2

Smoke Emission: IEC/BS EN 61034-2

Halogen Emission: IEC/BS EN 60754-1&2

Part No.

No. of Fibres

Sheath

Material

Sheath

Colour

Weight

kg/km

O/D

mm

FOM304TUH00 4 LSHF Black 34 6.5

FOM308TUH00 8 LSHF Black 39 7.0

FOM312TUH00 12 LSHF Black 43 7.5

FOM316TUH00 16 LSHF Black 52 8.0

FOM324TUH00 24 LSHF Black 63 8.5

Low Smoke Halogen Free

CPR-Compliant Options Available

Tel: 01727 840 841

FIBRE OPTIC


78

OM4 Loose Tube Fibre Multimode

OM4 50/125µm Loose Tube Fibre Optic Cable Unarmoured & Armoured Int/Ext

OM4 50/125µm fibres are great for high-speed data transfer around and between buildings. With lower losses than

OM3 fibre, OM4 is becoming the “go to” standard. OM4 fibre is backwards compatible with OM3 and can use the

same connectors. Although more expensive, OM4 fibre is coming down in price as volumes increase. Stocked in

armoured and unarmoured.

FOM412LUH00

OM4 Multimode 50/125µm Loose Tube Fibre Optic Unarmoured - U-DQ(ZN)BH

CONSTRUCTION

Single jelly filled central tube surrounded by waterblocked E-Glass fibre elements, LSHF UV resistant sheath to IEC

50290-2-27.

OPTICAL FIBRE TECHNICAL INFORMATION

Fibre Type: G651.1, OM4

Optical Fibre

Standards:

EN 60793-2-10 type A1a.3

TIA/EIA-492 AAAD

ANSI/TIA/EIA - 568.C

EN 50173-1 category OM4

ISO / IEC 11801 category OM4

ITU G.651.1

ISO/IEC 24764

IEEE 802.3

FINISHED CABLE TECHNICAL INFORMATION

Standards:

ISO 11801 2nd Edition

EN 50173-1-2002

IEC 60794-1

Temperature Rating: Flexing -30°C to +40°C

Static -30°C to +60°C

Minimum Bend Radius: Unloaded 60mm

Loaded 100mm

Flame Retardant: IEC/BS EN 60332-1-2

Smoke Emission: IEC/BS EN 61034-2

Halogen Emission: IEC/BS EN 60754-1&2

Part No.

No. of Fibres

Sheath

Material

Sheath

Colour

Weight

kg/km

O/D

mm

FOM404LUH00 4 LSHF Black 40 6.0

FOM408LUH00 8 LSHF Black 40 6.0

FOM412LUH00 12 LSHF Black 40 6.0

FOM416LUH00 16 LSHF Black 40 6.0

FOM424LUH00 24 LSHF Black 45 6.5

OM4 Multimode 50/125µm Loose Tube Fibre Optic Armoured - U-DQ(ZN)(SR)H

FOM412LUHC00

CONSTRUCTION

Single jelly filled central tube surrounded by waterblocked E-Glass fibre elements, corrugated steel tape armour,

LSHF UV resistant sheath to IEC 50290-2-27.

OPTICAL FIBRE TECHNICAL INFORMATION

Fibre Type: G651.1, OM4

Optical Fibre

Standards:

EN 60793-2-10 type A1a.3

TIA/EIA-492 AAAD

ANSI/TIA/EIA - 568.C

EN 50173-1 category OM4

ISO / IEC 11801 category OM4

ITU G.651.1

ISO/IEC 24764

IEEE 802.3

FINISHED CABLE TECHNICAL INFORMATION

Standards:

ISO 11801 2nd Edition

EN 50173-1-2002

IEC 60794-1

Temperature Rating: Flexing -40°C to +70°C

Static -40°C to +70°C

Minimum Bend Radius: 55mm

Flame Retardant: IEC/BS EN 60332-1-2

Smoke Emission: IEC/BS EN 61034-2

Halogen Emission: IEC/BS EN 60754-1&2

Part No.

No. of

Fibres

Armour

Sheath

Material

Sheath

Colour

Weight

kg/km

FOM404LUHC00 4 CST LSHF Black 75 8.5

FOM408LUHC00 8 CST LSHF Black 75 8.5

FOM412LUHC00 12 CST LSHF Black 75 8.5

FOM416LUHC00 16 CST LSHF Black 75 8.5

FOM424LUHC00 24 CST LSHF Black 85 8.5

O/D

mm

Low Smoke Halogen Free

Armoured

CPR-Compliant Options Available

www.fscables.com | sales@fscables.com


OM4 Tight Buffered Fibre Multimode

79

OM4 50/125µm Tight Buffered Fibre Optic Cable Int/Ext

Tight buffered OM4 50/125µm fibre is laid in a bed of E-Glass yarn and offers great tensile strength and crush resistance

whilst being easy to terminate. Due to the low loss performance OM4 fibre provides, installations can either be over

greater distances or have more couplings in them whilst still providing superior performance over OM3, with which it is

fully backward compatible. LSHF UV resistance jackets make the cable suitable for installation internally clipped to tray or

externally run through ducts.

OM4 Multimode 50/125µm Tight Buffered Fibre Optic Unarmoured - U-V(ZN)H

CONSTRUCTION

Tight buffered fibres packed along with E-glass roving strength members, LSHF UV resistant sheath to IEC

50290-2-27.

FOM408TUH00

OPTICAL FIBRE TECHNICAL INFORMATION

Fibre Type: G651.1, OM4

Optical Fibre

Standards:

EN 60793-2-10 type A1a.3

TIA/EIA-492 AAAD

ANSI/TIA/EIA - 568.C

EN 50173-1 category OM4

ISO / IEC 11801 category OM4

ITU G.651.1

ISO/IEC 24764

IEEE 802.3

FINISHED CABLE TECHNICAL INFORMATION

Standards:

ISO 11801 2nd Edition

EN 50173-1-2002

IEC 60794-1

Temperature Rating: Flexing -20°C to +70°C

Static -20°C to +70°C

Minimum Bend Radius: Up to 8 fibre 50mm

12 & 16 fibre 75mm

24 fibre 115mm

Flame Retardant: IEC/BS EN 60332-1-2

Smoke Emission: IEC/BS EN 61034-2

Halogen Emission: IEC/BS EN 60754-1&2

Part No.

No. of Fibres

Sheath

Material

Sheath

Colour

Weight

kg/km

O/D

mm

FOM404TUH00 4 LSHF Black 34 6.5

FOM408TUH00 8 LSHF Black 39 7.0

FOM412TUH00 12 LSHF Black 43 7.5

FOM416TUH00 16 LSHF Black 52 8.0

FOM424TUH00 24 LSHF Black 63 8.5

Low Smoke Halogen Free

CPR-Compliant Options Available

Tel: 01727 840 841

FIBRE OPTIC


80

Firetuf Optical Cable Unarmoured

Firetuf Fire Resistant Fibre Optic Cable Unarmoured

For critical circuits carrying essential data such as evacuation monitoring or backup instructions the Draka Firetuf fibre

optic cables are ideal. Tested to European and British standards that subject the cable to fire, for up to 2 hours, with

mechanical shock and water spray, the cables carry on functioning. Available using OS2, OM1, OM3 and OM4 fibre the

cables are used in Data centres, Transport systems, Tunnels, Hospitals and many other applications. Multi loose tube

and SWA armoured versions are also available. For more details, please visit www.fscables.com/ftfibre

FOM412LFTO03

Firetuf Fire Resistant Fibre Optic Cable Unarmoured - A/I-DQ(ZN)H

CONSTRUCTION

Single jelly filled central tube surrounded by waterblocked E-Glass fibre elements, LSHF Red UV resistant sheath

to IEC 50290-2-27.

OS2 OPTICAL FIBRE TECHNICAL INFORMATION

Fibre Type: G652D, OS2

Optical Fibre

Standards:

EN 60793-2-50 Category B.1.3

ITU-T Recommendation G.652.D and

C, B, A

EN 50173-1-2007, cat. OS2 & OS1

ISO / IEC 11801:2002, cat. OS2 & OS1

ISO / IEC 24702:2006, cat. OS2 & OS1

IEEE 802.3 - 2002 incl.802.3ae

OM3 OPTICAL FIBRE TECHNICAL INFORMATION

Fibre Type: G651.1, OM3

Optical Fibre

Standards:

EN 60793-2-10 type A1a.2

TIA/EIA-492 AAAC

ANSI/TIA/EIA - 568.C

EN 50173-1:2007 category OM3

ISO / IEC 11801 category OM3

ITU G.651.1

ISO/IEC 24764

FINISHED CABLE TECHNICAL INFORMATION

Standards:

ISO 11801 2nd Edition

EN 50173-1-2002

IEC 60794-1

Temperature Rating: Flexing 0°C to +50°C

Static -25°C to +70°C

Min. Bend Radius: Unloaded 121mm

Loaded 240mm

OM1 OPTICAL FIBRE TECHNICAL INFORMATION

Fibre Type: OM1

Optical Fibre

Standards:

EN 60793-2-10 type A1b

TIA/EIA-492 AAAA

ANSI/TIA/EIA - 568.B.3 - 2000

EN 50173-1:2007 category OM1

ISO / IEC 11801 category OM1

IEEE 802.3 - 2002 with ammendment

802.3ae - 2002

OM4 OPTICAL FIBRE TECHNICAL INFORMATION

Fibre Type: G651.1, OM4

Optical Fibre

Standards:

EN 60793-2-10 type A1a.3

TIA/EIA-492 AAAD

ANSI/TIA/EIA - 568.C

EN 50173-1 category OM4

ISO / IEC 11801 category OM4

ITU G.651.1

ISO/IEC 24764

IEEE 802.3

Flame Retardant: IEC/BS EN 60332-1-2,

IEC/BS EN 60332-3-24C

Fire Resistant: BS 8434-2, IEC 60332-25

(120), EN 50200 PH 120, EN

50200 ANNEX E PH 30

Smoke Emission: IEC/BS EN 61034-2

Halogen Emission: IEC/BS EN 60754-1&2

Part No.

No. of

Fibres

Fibre

Type

Sheath

Material

Sheath

Colour

Weight

kg/km

O/D

mm

FOM104LFTO03 4 OM1 LSHF Red 167 12.1

FOM108LFTO03 8 OM1 LSHF Red 167 12.1

FOM112LFTO03 12 OM1 LSHF Red 167 12.1

FOM124LFTO03 24 OM1 LSHF Red 167 12.1

FOM304LFTO03 4 OM3 LSHF Red 167 12.1

FOM308LFTO03 8 OM3 LSHF Red 167 12.1

FOM312LFTO03 12 OM3 LSHF Red 167 12.1

FOM324LFTO03 24 OM3 LSHF Red 167 12.1

FOM404LFTO03 4 OM4 LSHF Red 167 12.1

FOM408LFTO03 8 OM4 LSHF Red 167 12.1

FOM412LFTO03 12 OM4 LSHF Red 167 12.1

FOM424LFTO03 24 OM4 LSHF Red 167 12.1

FOS204LFTO03 4 OS2 LSHF Red 167 12.1

FOS208LFTO03 8 OS2 LSHF Red 167 12.1

FOS212LFTO03 12 OS2 LSHF Red 167 12.1

FOS224LFTO03 24 OS2 LSHF Red 167 12.1

Low Smoke Halogen Free

www.fscables.com | sales@fscables.com


Firetuf Optical Cable Armoured

81

Firetuf Fire Resistant Fibre Optic Cable Armoured

The Draka Firetuf armoured optical fibre cables are designed to cope with the toughest conditions when it comes to

both fire and mechanical damage. Being fire resistant these cables are outside the scope of CPR but it is reassuring

to know that they are LSHF and so they can be run in a single length between buildings without the need to cut and

terminate to a different cable, keeping losses to a minimum. Multi loose tube and SWA armoured versions are also

available. For more details, please visit www.fscables.com/ftfibre

Firetuf Fire Resistant Fibre Optic Cable Armoured - A/I-DQ(ZN)H(SR)H

CONSTRUCTION

Single jelly filled central tube surrounded by waterblocked E-Glass fibre elements, LSHF UV resistant sheath to IEC

50290-2-27.

FOM412LAFTO03

OS2 OPTICAL FIBRE TECHNICAL INFORMATION

Fibre Type: G652D, OS2

Optical Fibre

Standards:

EN 60793-2-50 Category B.1.3

ITU-T Recommendation G.652.D and

C, B, A

EN 50173-1-2007, cat. OS2 & OS1

ISO / IEC 11801:2002, cat. OS2 & OS1

ISO / IEC 24702:2006, cat. OS2 & OS1

IEEE 802.3 - 2002 incl.802.3ae

OM3 OPTICAL FIBRE TECHNICAL INFORMATION

Fibre Type: G651.1, OM3

Optical Fibre

Standards:

EN 60793-2-10 type A1a.2

TIA/EIA-492 AAAC

ANSI/TIA/EIA - 568.C

EN 50173-1:2007 category OM3

ISO / IEC 11801 category OM3

ITU G.651.1

ISO/IEC 24764

FINISHED CABLE TECHNICAL INFORMATION

Standards:

ISO 11801 2nd Edition

EN 50173-1-2002

IEC 60794-1

Temperature Rating: Flexing 0°C to +50°C

Static -40°C to +70°C

Min. Bend Radius: Unloaded 255mm

Loaded 340mm

OM1 OPTICAL FIBRE TECHNICAL INFORMATION

Fibre Type: OM1

Optical Fibre

Standards:

EN 60793-2-10 type A1b

TIA/EIA-492 AAAA

ANSI/TIA/EIA - 568.B.3 - 2000

EN 50173-1:2007 category OM1

ISO / IEC 11801 category OM1

IEEE 802.3 - 2002 with ammendment

802.3ae - 2002

OM4 OPTICAL FIBRE TECHNICAL INFORMATION

Fibre Type: G651.1, OM4

Optical Fibre

Standards:

EN 60793-2-10 type A1a.3

TIA/EIA-492 AAAD

ANSI/TIA/EIA - 568.C

EN 50173-1 category OM4

ISO / IEC 11801 category OM4

ITU G.651.1

ISO/IEC 24764

IEEE 802.3

Flame Retardant: IEC/BS EN 60332-1-2,

IEC/BS EN 60332-3-24C

Fire Resistant: BS 8434-2 , IEC 60332-25

(120), EN 50200 PH 120, EN

50200 ANNEX E PH 30

Smoke Emission: IEC/BS EN 61034-2

Halogen Emission: IEC/BS EN 60754-1&2

Part No.

No. of

Fibres

Fibre

Type

Sheath

Material

Sheath

Colour

Weight

kg/km

O/D

mm

FOM104LAFTO03 4 OM1 LSHF Black 351 17.0

FOM108LAFTO03 8 OM1 LSHF Black 351 17.0

FOM112LAFTO03 12 OM1 LSHF Black 351 17.0

FOM124LAFTO03 24 OM1 LSHF Black 351 17.0

FOM304LAFTO03 4 OM3 LSHF Black 351 17.0

FOM308LAFTO03 8 OM3 LSHF Black 351 17.0

FOM312LAFTO03 12 OM3 LSHF Black 351 17.0

FOM324LAFTO03 24 OM3 LSHF Black 351 17.0

FOM404LAFTO03 4 OM4 LSHF Black 351 17.0

FOM408LAFTO03 8 OM4 LSHF Black 351 17.0

FOM412LAFTO03 12 OM4 LSHF Black 351 17.0

FOM424LAFTO03 24 OM4 LSHF Black 351 17.0

FOS204LAFTO03 4 OS2 LSHF Black 351 17.0

FOS208LAFTO03 8 OS2 LSHF Black 351 17.0

FOS212LAFTO03 12 OS2 LSHF Black 351 17.0

FOS224LAFTO03 24 OS2 LSHF Black 351 17.0

Armoured

Tel: 01727 840 841

FIBRE OPTIC


82

Duplex Fibre Optic

Duplex Fibre Optic Cable

Duplex Fibre cables were originally developed as a convenient way to manufacture patch cables in various lengths.

Although this is still their primary use, some customers are using them, pre-terminated in longer lengths, to run between

rooms or floors. This is particularly popular with Home Automation and high-end AV installers. Available in OS2, OM1,

OM3 and OM4 and colour coded and easy to strip and terminate.

FOM302TUH

OM3 Duplex Fibre Optic Cable - J-V(ZN)H 2

CONSTRUCTION

Two tight buffered fibres surrounded by high strength aramid glass yarn, LSHF UV resistant sheath to IEC 50290-

2-27.

OS2 OPTICAL FIBRE TECHNICAL INFORMATION

Fibre Type: G652D, OS2

Optical Fibre

Standards:

EN 60793-2-50 Category B.1.3

ITU-T Recommendation G.652.D and

C, B, A

EN 50173-1-2007, cat. OS2 & OS1

ISO / IEC 11801:2002, cat. OS2 & OS1

ISO / IEC 24702:2006, cat. OS2 & OS1

IEEE 802.3 - 2002 incl.802.3ae

OM1 OPTICAL FIBRE TECHNICAL INFORMATION

Fibre Type: OM1

Optical Fibre

Standards:

EN 60793-2-10 type A1b

TIA/EIA-492 AAAA

NSI/TIA/EIA - 568.B.3 - 2000

EN 50173-1:2007 category OM1

ISO / IEC 11801 category OM1

IEEE 802.3 - 2002 with ammendment

802.3ae - 2002

OM3 OPTICAL FIBRE TECHNICAL INFORMATION

Fibre Type: G651.1, OM3

Optical Fibre

Standards:

EN 60793-2-10 type A1a.2

TIA/EIA-492 AAAC

ANSI/TIA/EIA - 568.C

EN 50173-1:2007 category OM3

ISO / IEC 11801 category OM3

ITU G.651.1

ISO/IEC 24764

FINISHED CABLE TECHNICAL INFORMATION

Standards:

ISO 11801 2nd Edition

EN 50173-1-2002

IEC 60794-1

Temperature Rating: Flexing -40°C to +70°C

Static -30°C to +60°C

Min. Bend Radius: 20mm

OM4 OPTICAL FIBRE TECHNICAL INFORMATION

Fibre Type: G651.1, OM4

Optical Fibre

Standards:

EN 60793-2-10 type A1a.3

TIA/EIA-492 AAAD

ANSI/TIA/EIA - 568.C

EN 50173-1 category OM4

ISO / IEC 11801 category OM4

ITU G.651.1

ISO/IEC 24764

IEEE 802.3

Flame Retardant: IEC/BS EN 60332-1-2,

IEC/BS EN 60332-3-24C

Smoke Emission: IEC/BS EN 61034-2

Halogen Emission: IEC/BS EN 60754-1&2

Part No.

No. of

Fibres

Fibre

Type

Sheath

Material

Sheath

Colour

Weight

kg/km

FOS202TUH09 2 Duplex OS2 LSHF Yellow 20 2.9 x 5.9

FOM102TUH05 2 Duplex OM1 LSHF Grey 20 2.9 x 5.9

FOM302TUH 2 Duplex OM3 LSHF Aqua 20 2.9 x 5.9

FOM402TUH 2 Duplex OM4 LSHF Aqua 20 2.9 x 5.9

O/D

mm

Low Smoke Halogen Free

www.fscables.com | sales@fscables.com


Pre Terminated Fibre Optic

83

Pre Terminated Fibre Optic Cable

Pre-terminated fibre optic leads are becoming increasingly popular with installers where fibre is not their main business.

Pre-tested to ensure performance, it avoids the need for the installer to invest in costly test and termination equipment.

A wide range of both cable types and connectors are available with individual leads manufactured to order in the length

you need on short lead times.

SELECTING YOUR FIBRE OPTIC CABLE

Select from each of the options in the table below and let us know the length you require. Then call a member

of our technical sales team or email us at sales@fscables.com and we will contact you with a quote and lead

time. It is also possible to add multiple connector types at a single end, call to discuss your requirements on

01727 840841.

Fibre Type Singlemode OS2 Multimode OM1 Multimode OM3 Multimode OM4

No. of Fibres 4 8 12 16 24 48

Construction Tight Buffered Loose Tube Breakout Fibre

Connector Type End 1 ST LC SC FC MTRJ

Connector Type End 2 ST LC SC FC MTRJ

Armouring Unarmoured Corrugated Steel Tape Steel Wire Armour

LENGTH - ARE THERE PRE-DEFINDED LENGTHS?

These pre-terminated fibre optic cables all come complete with a pulling sock to protect the connector and make

installation easier.

Tel: 01727 840 841

FIBRE OPTIC


84

NEK Marine Approved Fibre Optic

NEK Marine Approved Fibre Optic Cables

Designed for use on yachts, tankers, cargo carriers and offshore rigs the range of marine fibre optic cables have been

tested and approved by DNV-GL and ABS as well as being fully compliant with the relevant IEC standards.

Using some of the highest grade LSZH compounds to SHF1, SHF2 and SHF2-Mud-NEK606 they provide excellent

resistance to UV, Oil and many chemicals and operate at low temperatures. See pages 188 - 191 in the Marine section

for more information.

QFCI Fire Resistant Fibre Optic Cable

TECHNICAL INFORMATION

Type:

QFCI Loose Tube

Armour:

Galvansied Steel Wire Braid

Fire Resistant: IEC 60331-25

Core Count Options: 2, 4, 6, 8, 12, 24, 48

Approval:

DNV-GL & ABS

Fibre Grade Options: 62.5/125μm multimode OM1

50/125μm multimode OM2, OM3, OM4

9/125μm singlemode OS2

Sheath Material Options: SHF1 - LSHF Thermoplastic

SHF2 - LSHF Thermoset

SHF2 - MUD LSHF Thermoset

Page: 188 - 191

AICI Fibre Optic Cable

TECHNICAL INFORMATION

Type:

AICI Tight Buffered

Armour:

Galvansied Steel Wire Braid

Core Count Options: 4, 6, 8, 12, 24

Approval:

DNV-GL & ABS

Fibre Grade Options: 62.5/125μm multimode OM1

50/125μm multimode OM2, OM3, OM4

9/125μm singlemode OS2

Sheath Material Options: SHF1 - LSHF Thermoplastic

SHF2 - LSHF Thermoset

SHF2 - MUD LSHF Thermoset

Page: 191

www.fscables.com | sales@fscables.com


85

LSHF

Introduction

Recent figures show that around 4,000 people die each

year in fires in Europe. Of these, 90% of the deaths are

in buildings and around 90% of these are overcome

by smoke & fumes and not by the fire itself. That’s over

3,200 people killed by toxic fumes & gases.

Low Smoke Halogen Free (LSHF) cables emit minimal

levels of toxic fumes and smoke in the event of a fire.

They are ideal for installations in areas that may be

difficult to evacuate in the event of fire such as airports,

hospitals or Underground/Metro stations or confined

areas such as computer rooms and other sensitive

environments.

Standard PVC cables are made up of Hydrocarbons

which, when burnt, give off toxic gases such as

hydrogen chloride gas. Specifying Low Smoke Halogen

Free (LSHF) cable goes a long way to reducing this risk.

Compared to standard PVC which emits around 28%

acid gas, LSHF cables produce less than 0.5% HCl

(Gases Evolved During Combustion BS EN 60754-2).

Visibility through smoke emission is measured using a

3m³ smoke test to BS EN/IEC 61034. Most LSHF cables

produce very little smoke as opposed to standard PVC

which gives off dense black smoke.

Confusion still surrounds the terminology used to

describe LSHF cables. While LSHF, LS0H, LSZH, LSNH

and 0HLS are all the same, LSF (Low Smoke & Fume)

may not be.

LSF data, signal, control & flexible cables often contain

PVC compounds and can still emit in excess of 22%

HCl. They should be regarded as only slightly better

than PVC in the event of fire. The LSF cables in this

book are PVC based and not halogen free.

If you are unsure of what you are buying, ask for

written confirmation that the cable is LSHF throughout.

A PVC insulation with an LSHF jacket is very dangerous

in the event of a fire.

At FSC when you select LSHF, you can be confident

you are buying a high quality Low Smoke Halogen Free

cable throughout - cores, jacket and other elements.

Contents

Niltox LF-249, H05Z-K & H07ZK 86

Niltox LF-318, H05Z1Z1-F 87

Niltox LF-319 Unscreened 88 & 89

Niltox LF-329 Foil & Braid Screened 90 & 91

RiserFlex 0.6/1kV 92

RiserShield 0.6/1kV 93

Niltox LF-315 Miniature

Braid Screened

Niltox LF-316 Twisted Pair

Braid Screened

94

95

LSHF Def-Standard 96 & 97

Niltox LF-349 GSWB 98

Tel: 01727 840 841

LSHF


86

Niltox ® LF-249 H05Z-K & H07Z-K (2491B & 6701B)

Niltox ® LF-249 H05Z-K & H07Z-K (2491B & 6701B)

2491B and 6701B are flexible single cores with class 5 stranding conforming to the harmonisation standard H05Z-K and

H07Z-K for Low Smoke Halogen Free (LSHF) single core cable. Applications include panel and conduit wiring where its

flexibility makes installation easier.

Public and government buildings are increasingly using LSHF cabling to reduce the risk of injury through smoke

inhalation in the event of a fire. The cables also produce fewer gases which are less corrosive when burnt, which is

particularly important where sensitive electronic equipment is installed such as in computer rooms.

24901501

CONSTRUCTION

Plain fine copper wire strands to BS EN 60228 class

5. Thermosetting insulation of LSHF compound.

TECHNICAL INFORMATION

Voltage Rating: Up to 1.0mm 2 300/500V

1.5mm 2 and above 450/750V

Temperature Rating:

Current Rating:

15°C to +90°C

4E1A & B

Conductor Stranding: BS EN 60228 Class 5

Manufactured to: BS EN 50525-3-41

Flame Retardant: IEC/BS EN 60332-1-2

24916099

Part No. Size mm 2 No. of Strands/mm* Weight kg/km O/D mm

249005xx 0.5 16/0.20 10 2.1

249007xx 0.75 24/0.20 13 2.7

249010xx 1.0 32/0.20 16 2.8

249015xx 1.5 30/0.25 21 3.3

249025xx 2.5 50/0.25 33 4.1

249040xx 4.0 56/0.30 49 4.7

249060xx 6.0 84/0.30 70 5.3

249100xx 10 80/0.40 125 6.9

249160xx 16 126/0.40 180 8.2

249250xx 25 196/0.40 275 10.3

249350xx 35 276/0.40 380 11.7

249500xx 50 400/0.40 560 14.0

249700xx 70 356/0.50 780 15.8

249950xx 95 485/0.50 1000 18.0

249120xx 120 614/0.50 1300 20.4

249150xx 150 765/0.50 1600 22.6

249185xx 185 944/0.50 2000 24.6

249240xx 240 1225/0.50 2600 28.5

To show the colour required please replace xx in the part number with:

00 Black

01 Blue

02 Brown

03 Red

04 White

05 Grey

06 Violet

07 Pink

08 Orange

09 Yellow

10 Green

99 Green/Yellow

Standard pack size for conductor sizes up to and including 16mm 2 is 100m, with some sizes/colours stocked on 500m

reels. 25mm² and above is normally stocked on bulk reels and can be cut to the length you require. Not all colours are

available in the larger sizes.

* Stranding column is for guidance only, the conductors meet

BS EN/IEC 60228 Class 5 as shown on page 209.

CPR-Compliant Options Available

www.fscables.com | sales@fscables.com


Niltox ® LF-318 LSHF Colour Coded Multicore

87

Niltox ® LF-318 LSHF Colour Coded Multicore

Low Smoke Halogen Free (LSHF) compounds are used to produce this high quality flexible cable that meets the

requirements of 318* B and H05Z1Z1-F. Niltox LF-318 is ideal for applications where the cable will be visible. Examples

include lighting pendant drops, supply leads and general wiring in public areas.

As an option, these cables can be oversheathed in a wide variety of colours in LSHF compounds. This is particularly useful

when quantities are small or cables are needed quickly.

CONSTRUCTION

Fine copper wire strands to BS EN 60228 class 5,

LSHF insulation, colour coded to BS 7671 HD 308

S2. White or black LSHF outer sheath.

TECHNICAL INFORMATION

Voltage Rating: 300/500V Test 3000V

Temperature Rating:

Bending Radius:

Current Rating:

-5°C to +70°C

Flexing 12 x cable diameter

Static 6 x cable diameter

Refer to IEE Regs Table 4F3A&B

Flame Retardant: IEC/BS EN 60332-1-2

Smoke Emission: IEC/BS EN 61034-2

Halogen Emission:

IEC/BS EN 60754-1 & 2 &

50267-2-1

Manufactured to: BS EN 50525-3-11

3180150300

Part No.

Cores x

mm 2

Weight

kg/km

O/D

mm

31800702xx 2 x 0.75 55 6.2

31800703xx 3 x 0.75 66 6.6

31800704xx 4 x 0.75 81 7.2

31800705xx 5 x 0.75 100 8.0

31801002xx 2 x 1.0 64 6.6

31801003xx 3 x 1.0 77 7.0

31801004xx 4 x 1.0 98 7.8

31801005xx 5 x 1.0 120 8.6

3180100504DL 5 x 1.0 120 8.6

31801006xx 6 x 1.0 150 9.5

31801502xx 2 x 1.5 87 7.6

31801503xx 3 x 1.5 109 8.2

31801504xx 4 x 1.5 141 9.3

31801505xx 5 x 1.5 174 10.3

3180150504DL 5 x 1.5 174 10.3

31801506xx 6 x 1.5 212 11.4

Part No.

Cores x

mm 2

Weight

kg/km

O/D

mm

31802502xx 2 x 2.5 132 9.2

31802503xx 3 x 2.5 166 10.0

31802504xx 4 x 2.5 205 10.9

31802505xx 5 x 2.5 254 12.1

31804003xx 3 x 4.0 229 11.4

31804004xx 4 x 4.0 286 12.5

31804005xx 5 x 4.0 362 14.1

3180150404

To show the colour required please replace xx in the part number with:

04 White 00 Black

Colour Code:

2 core Blue Brown

3 core Blue

4 core Brown

5 core Blue

6 core Blue

5 core Dali Blue

Brown Green/Yellow

Black Grey Green/Yellow

Brown Black Grey Green/Yellow

Brown Black Red White Green/Yellow

Brown Green/Yellow Red White CPR-Compliant Options Available

Tel: 01727 840 841

LSHF


88

Niltox ® LF-319 LSHF

Niltox ® LF-319 LSHF Multicore

Developed to meet the need for Low Smoke Halogen Free (LSHF) control cables, the Niltox LF-319 range of LSHF YY

control cables covers all the popular sizes. Applications include airports, hospitals, lift shafts, tunnels, heating and

ventilating controls, in fact anywhere that conventional PVC YY cables were previously used. In addition to its LSHF

properties, this cable offers a high degree of flame retardance thereby reducing the risk of spreading fire. Stocked on

bulk reels, Niltox LF-319 cables can be cut to the length you require, saving you money.

31901507

CONSTRUCTION

Fine copper wire strands to BS EN 60228 class 5,

LSHF insulation, number or colour coding, a green/

yellow earth core is included in cables with more

than 2 cores, grey LSHF outer sheath.

TECHNICAL INFORMATION

Voltage Rating: 300/500V

Temperature Rating:

Bending Radius:

Current Rating:

Flexing -15ºC to +90ºC

Static -25ºC to +90ºC

Flexing 15 x cable diameter

Static 7.5 x cable diameter

Refer to IEE Regs Table 4F3A&B

Flame Retardant: IEC/BS EN 60332-1-2,

IEC/BS EN 60332-3-24C, UL 1685

Smoke Emission: IEC/BS EN 61034-2, UL 1685

Halogen Emission: IEC/BS EN 60754-1 & 2

Part No.

Cores x

mm 2

Weight

kg/km

O/D

mm

Part No.

Cores x

mm 2

Weight

kg/km

O/D

mm

Number Coded 1 2 3 4 5

31900702 2 x 0.75 45 5.4

31900703 3 x 0.75 55 5.9

31900704 4 x 0.75 65 6.4

31900705 5 x 0.75 76 7.0

31900707 7 x 0.75 93 7.5

31900712 12 x 0.75 140 10.1

31900718 18 x 0.75 240 12.1

31900725 25 x 0.75 343 14.2

31900730 30 x 0.75 470 15.5

31900734 34 x 0.75 525 16.5

31900741 41 x 0.75 620 17.8

31900750 50 x 0.75 750 19.8

31901002 2 x 1.0 49 5.7

31901003 3 x 1.0 59 6.2

31901004 4 x 1.0 75 6.7

31901005 5 x 1.0 88 7.4

31901007 7 x 1.0 112 8.0

31901012 12 x 1.0 170 10.7

31901018 18 x 1.0 252 12.9

31901025 25 x 1.0 363 15.0

31901034 34 x 1.0 685 17.6

31901041 41 x 1.0 790 18.8

31901050 50 x 1.0 870 21.2

Number Coded 1 2 3 4 5

31901502 2 x 1.5 73 6.8

31901503 3 x 1.5 78 7.3

31901504 4 x 1.5 105 8.0

31901505 5 x 1.5 133 9.0

31901507 7 x 1.5 165 9.7

31901512 12 x 1.5 274 13.0

31901518 18 x 1.5 402 15.5

31901525 25 x 1.5 533 18.3

31901534 34 x 1.5 850 19.9

31901550 50 x 1.5 1285 23.9

31901561 61 x 1.5 1475 25.4

31901565 65 x 1.5 1650 26.2

31902502 2 x 2.5 94 7.7

31902503 3 x 2.5 123 8.4

31902504 4 x 2.5 158 9.3

31902505 5 x 2.5 192 10.1

31902507 7 x 2.5 246 11.1

31902512 12 x 2.5 360 14.9

31902518 18 x 2.5 780 18.3

31902525 25 x 2.5 1050 22.1

31904002 2 x 4.0 172 9.3

31904003 3 x 4.0 185 10.4

31904004 4 x 4.0 198 11.6

31904005 5 x 4.0 270 13.3

31904007 7 x 4.0 475 15.5

31904012 12 x 4.0 800 18.5

Also available with a black sheath in some sizes.

Other sizes are available on short lead times.

CPR-Compliant Options Available

www.fscables.com | sales@fscables.com


Niltox ® LF-319 LSHF

89

Part No.

Cores x

mm 2

Weight

kg/km

O/D

mm

Number Coded 1 2 3 4 5

31906002 2 x 6.0 243 10.9

31906003 3 x 6.0 260 11.9

31906004 4 x 6.0 285 13.5

31906005 5 x 6.0 420 14.7

31906007 7 x 6.0 640 16.2

31910003 3 x 10 550 15.1

31910004 4 x 10 710 17.4

31910005 5 x 10 875 19.3

31916003 3 x 16 850 17.8

31916004 4 x 16 1050 21.9

31916005 5 x 16 1300 24.5

31925003 3 x 25 1150 22.6

31925004 4 x 25 1600 26.6

31925005 5 x 25 2100 29.5

31935003 3 x 35 1600 25.5

31935004 4 x 35 2210 33.4

31935005 5 x 35 2700 37.0

31950003 3 x 50 2600 30.0

31950004 4 x 50 3100 37.8

31950005 5 x 50 4000 42.9

31970003 3 x 70 3250 37.2

31970004 4 x 70 4100 41.4

31970005 5 x 70 5500 46.2

31995003 3 x 95 4750 41.5

31995004 4 x 95 5600 46.3

31995005 5 x 95 7000 50.8

31912003 3 x 120 5600 46.0

31912004 4 x 120 7150 50.5

Part No.

Colour Coded

Cores x

mm 2

Weight

kg/km

O/D

mm

31901502C 2 x 1.5 73 6.8

31901503C 3 x 1.5 78 7.3

31901504E 4 x 1.5 105 8.0

31901505E 5 x 1.5 133 9.0

31902502C 2 x 2.5 94 7.7

31902503C 3 x 2.5 123 8.4

31902504E 4 x 2.5 158 9.3

31902505E 5 x 2.5 192 10.1

31904003C 3 x 4.0 185 10.4

31904004E 4 x 4.0 198 11.6

31904005E 5 x 4.0 270 13.3

31906003C 3 x 6.0 260 11.5

31906004E 4 x 6.0 285 13.5

31906005E 5 x 6.0 420 14.7

31910003C 3 x 10 550 15.1

31910004C 4 x 10 710 17.4

31910005C 5 x 10 875 19.3

31916003C 3 x 16 850 17.8

31916004C 4 x 16 1050 21.9

31916005C 5 x 16 1300 24.5

31925003C 3 x 25 1150 22.6

31925004C 4 x 25 1600 26.6

31925005C 5 x 25 2100 29.5

31935003C 3 x 35 1600 25.5

31935004C 4 x 35 2210 33.4

31935005C 5 x 35 2700 37.0

31950003C 3 x 50 2600 30.0

31950004C 4 x 50 3100 37.8

31950005C 5 x 50 4000 42.9

31906003E

Colour Code:

2 core Blue Brown

3 core Blue Brown Green/Yellow

4 core Brown Black Grey Green/Yellow

5 core Blue Brown Black Grey Green/Yellow CPR-Compliant Options Available

Tel: 01727 840 841

LSHF


90

Niltox ® LF-329 LSHF

Niltox ® LF-329 Dual Screened LSHF Multicore

Niltox LF-329 is a Low Smoke Halogen Free (LSHF) alternative to the popular PVC LiYCY screened signal, control & power

cable but with dual screening. This offers a higher level of screening against both high and low-frequency electromagnetic

interference (EMI). Available from 0.75mm² to 120mm² these cables are LSHF throughout. Flexibility is excellent making

installation easy. Core identification is straightforward with cores being either clearly number coded or colour coded and

a green/yellow earth core included in cables with more than 2 cores. Applications include hospitals, airports, computer

suites and control rooms, in fact anywhere where power or signals need to be protected from electromagnetic radiation

or from corrupting other cables or equipment. The LSHF properties protect both people and equipment.

32900707

CONSTRUCTION

Fine copper wire strands to BS EN 60228 class

5, LSHF insulation, number or colour coding,

a green/yellow earth core is included in cables

with more than 2 cores, cores twisted together,

polyester tape, overall aluminium foil & tinned

copper wire braid, grey LSHF sheath.

TECHNICAL INFORMATION

Voltage Rating: 300/500V

Temperature Rating:

Bending Radius:

Flexing -15ºC to +90ºC

Static -25ºC to +90ºC

Flexing 10 x cable diameter

Static 7.5 x cable diameter

Flame Retardant: IEC/BS EN 60332-1-2,

IEC/BS EN 60332-3-24C, UL 1685

Smoke Emission: IEC/BS EN 61034-2, UL 1685

Halogen Emission: IEC/BS EN 60754-1 & 2

Part No.

Cores x

mm 2

Weight

kg/km

O/D

mm

Part No.

Cores x

mm 2

Weight

kg/km

O/D

mm

Number Coded 1 2 3 4 5

32900702 2 x 0.75 56 6.1

32900703 3 x 0.75 64 6.4

32900704 4 x 0.75 74 6.9

32900705 5 x 0.75 83 7.6

32900707 7 x 0.75 106 8.1

32900712 12 x 0.75 200 10.9

32900718 18 x 0.75 295 12.5

32900725 25 x 0.75 420 14.8

32901002 2 x 1.0 60 6.4

32901003 3 x 1.0 66 6.7

32901004 4 x 1.0 83 7.4

32901005 5 x 1.0 100 8.1

32901007 7 x 1.0 130 9.0

32901012 12 x 1.0 270 11.8

32901018 18 x 1.0 390 13.7

32901025 25 x 1.0 545 16.2

32901502 2 x 1.5 72 7.7

32901503 3 x 1.5 97 8.1

32901504 4 x 1.5 114 9.0

32901505 5 x 1.5 135 10.0

32901507 7 x 1.5 176 10.6

32901512 12 x 1.5 300 14.1

32901518 18 x 1.5 500 16.4

32901525 25 x 1.5 710 19.5

Number Coded 1 2 3 4 5

32902502 2 x 2.5 123 8.8

32902503 3 x 2.5 132 9.3

32902504 4 x 2.5 152 10.1

32902505 5 x 2.5 215 11.1

32902507 7 x 2.5 250 12.1

32902512 12 x 2.5 580 15.9

32904002 2 x 4.0 190 11.1

32904003 3 x 4.0 220 11.7

32904004 4 x 4.0 310 13.0

32904005 5 x 4.0 395 13.4

32904007 7 x 4.0 510 14.1

32906002 2 x 6.0 280 11.6

32906003 3 x 6.0 325 13.2

32906004 4 x 6.0 360 15.5

32906005 5 x 6.0 520 16.2

32906007 7 x 6.0 675 16.7

32910003 3 x 10 450 16.8

32910004 4 x 10 790 18.5

32910005 5 x 10 620 20.8

32916003 3 x 16 690 19.0

32916004 4 x 16 1300 22.7

32916005 5 x 16 2200 25.3

CPR-Compliant Options Available

www.fscables.com | sales@fscables.com


Niltox ® LF-329 LSHF

91

Part No.

Cores x

mm 2

Weight

kg/km

O/D

mm

Number Coded 1 2 3 4 5

32925003 3 x 25 1450 23.3

32925004 4 x 25 1950 26.4

32925005 5 x 25 2450 29.5

32935003 3 x 35 2000 25.9

32935004 4 x 35 2575 30.5

32935005 5 x 35 3200 34.0

32950003 3 x 50 3100 30.2

32950004 4 x 50 3600 34.8

32950005 5 x 50 4800 40.0

32970003 3 x 70 3900 37.8

32970004 4 x 70 5000 41.4

32970005 5 x 70 6600 46.3

32995003 3 x 95 5700 41.3

32995004 4 x 95 6700 46.4

32995005 5 x 95 8400 51.5

32912003 3 x 120 6400 46.7

32912004 4 x 120 8500 51.2

Part No.

Colour Coded

Cores x

mm 2

Weight

kg/km

O/D

mm

32901502C 2 x 1.5 72 7.7

32901503C 3 x 1.5 97 8.1

32901504E 4 x 1.5 114 9.0

32901505E 5 x 1.5 135 10.0

32902502C 2 x 2.5 123 8.8

32902503C 3 x 2.5 132 9.3

32902504E 4 x 2.5 152 10.1

32902505E 5 x 2.5 215 11.1

32904003C 3 x 4.0 220 11.7

32904004E 4 x 4.0 310 13.0

32904005E 5 x 4.0 395 13.4

32906003C 3 x 6.0 325 13.2

32906004E 4 x 6.0 360 15.5

32906005E 5 x 6.0 520 16.2

32910003C 3 x 10 450 16.8

32910004E 4 x 10 790 18.5

32910005E 5 x 10 620 20.8

32916003C 3 x 16 690 19.0

32916004E 4 x 16 1300 22.7

32916005E 5 x 16 2200 25.3

32925003C 3 x 25 1450 23.3

32925004E 4 x 25 1950 26.4

32925005E 5 x 25 2450 29.5

32935003C 3 x 35 2000 25.9

32935004E 4 x 35 2575 30.5

32935005E 5 x 35 3200 34.0

32901503C

Colour Code:

2 core Blue Brown

3 core Blue Brown Green/Yellow

4 core Brown Black Grey Green/Yellow

5 core Blue Brown Black Grey Green/Yellow CPR-Compliant Options Available

Tel: 01727 840 841

LSHF


92

RiserFlex 0.6/1kV

RiserFlex 0.6/1kV

Developed to meet the latest building requirements this Low Smoke Halogen Free (LSHF) cable is 0.6/1kV rated making it

ideal to run in risers or under floors.

The conductors are finely stranded to BS EN 60228 class 5 making installation simple and routing easy. Cores are colour

coded in cables up to 5 cores. Above this, they are black with white numbers. Cores are also rated at 0.6/1kV to comply

with regulations for power cables in protected installations. Applications include wiring to computer systems, lift shafts,

HVAC, security systems and BMS.

32801504

CONSTRUCTION

Fine copper wire strands to BS EN 60228 class 5,

XLPE insulation, cores laid up, black LSHF sheath.

TECHNICAL INFORMATION

Voltage Rating:

Temperature Rating:

Bending Radius:

Working 0.6/1kV

Static -20ºC to +70ºC

Static 4 x cable diameter

Flame Retardant: IEC/BS EN 60332-1-2

Smoke Emission: IEC/BS EN 61034-2

Halogen Emission: IEC/BS EN 60754-1 & 2

Core Identification:

Up to 5 core in accordance with

BS7671. Above 5 core, black

numbered cores & G/Y earth

32802507

Part No.

Cores x

mm 2

Weight

kg/km

O/D

mm

32800702 2 x 0.75 75 6.8

32800703 3 x 0.75 95 7.5

32800704 4 x 0.75 120 8.0

32800705 5 x 0.75 150 8.9

32800707 7 x 0.75 185 10.3

32801002 2 x 1.0 100 8.9

32801003 3 x 1.0 120 9.4

32801004 4 x 1.0 140 9.8

32801005 5 x 1.0 170 10.5

32801007 7 x 1.0 210 11.3

32801502 2 x 1.5 140 9.4

32801503 3 x 1.5 165 10.0

32801504 4 x 1.5 190 10.6

32801505 5 x 1.5 225 11.7

32801507 7 x 1.5 270 12.8

32801512 12 x 1.5 420 16.4

Part No.

Cores x

mm 2

Weight

kg/km

O/D

mm

32802502 2 x 2.5 190 9.9

32802503 3 x 2.5 220 11.1

32802504 4 x 2.5 265 12.0

32802505 5 x 2.5 310 13.1

32802507 7 x 2.5 390 14.2

32804003 3 x 4.0 280 12.3

32804004 4 x 4.0 345 13.8

32804005 5 x 4.0 410 14.7

32806003 3 x 6.0 395 14.7

32806004 4 x 6.0 460 15.3

32806005 5 x 6.0 550 16.6

32810003 3 x 10 595 16.5

32810004 4 x 10 680 18.4

Colour Code:

2 core Blue Brown

3 core Blue

4 core Brown

Brown Green/Yellow

Black Grey Green/Yellow

5 core Blue Brown Black Grey Green/Yellow CPR-Compliant Options Available

www.fscables.com | sales@fscables.com


RiserShield 0.6/1kV

93

RiserShield 0.6/1kV

RiserShield is a 0.6/1kV dual screened power, control and signal cable using Low Smoke Halogen Free (LSHF) materials

throughout. Developed to run alongside power cables RiserShield is particularly popular for running clean supplies to

computer equipment.

The double shield is effective at reducing both radiated and induced interference. The class 5 flexible conductors ensure

the cable can be easily routed even through confined spaces.

CONSTRUCTION

Fine copper wire strands to BS EN 60228 class 5,

XLPE insulation, cores laid up, overall aluminium

foil and tinned copper wire braid, black LSHF

sheath.

TECHNICAL INFORMATION

Voltage Rating:

Temperature Rating:

Bending Radius:

Working 0.6/1kV

Static -20ºC to +70ºC

Static 7.5 x cable diameter

Flame Retardant: IEC/BS EN 60332-1-2

Smoke Emission: IEC/BS EN 61034-2

Halogen Emission: IEC/BS EN 60754-1 & 2

Core Identification:

Up to 5 core in accordance with

BS7671. Above 5 core, black

numbered cores & G/Y earth

42601507

Part No.

Cores x

mm 2

Weight

kg/km

O/D

mm

42600702 2 x 0.75 105 7.9

42600703 3 x 0.75 111 8.4

42600704 4 x 0.75 132 9.0

42600705 5 x 0.75 149 9.8

42600707 7 x 0.75 215 10.9

42601002 2 x 1.0 126 9.4

42601003 3 x 1.0 141 9.9

42601004 4 x 1.0 167 10.6

42601005 5 x 1.0 196 11.4

42601007 7 x 1.0 282 12.1

42601502 2 x 1.5 149 10.5

42601503 3 x 1.5 173 11.1

42601504 4 x 1.5 191 11.9

42601505 5 x 1.5 216 12.5

42601507 7 x 1.5 314 13.5

Part No.

Cores x

mm 2

Weight

kg/km

O/D

mm

42602502 2 x 2.5 206 11.5

42602503 3 x 2.5 263 12.2

42602504 4 x 2.5 299 13.2

42602505 5 x 2.5 329 14.0

42602507 7 x 2.5 471 15.5

42604003 3 x 4.0 295 13.8

42604004 4 x 4.0 376 14.9

42604005 5 x 4.0 483 16.2

42606003 3 x 6.0 390 15.6

42606004 4 x 6.0 459 26.4

42606005 5 x 6.0 597 17.7

42610003 3 x 10 882 19.2

42610004 4 x 10 1049 20.4

42606004

Colour Code:

2 core Blue Brown

3 core Blue

4 core Brown

Brown Green/Yellow

Black Grey Green/Yellow

5 core Blue Brown Black Grey Green/Yellow CPR-Compliant Options Available

Tel: 01727 840 841

LSHF


94

Niltox ® LF-315 LSHF

Niltox ® LF-315 Screened LSHF Multicore

Developed for signal and control applications in sensitive areas, the Niltox LF-315 range offers excellent flame retardance

while emitting no halogens or other corrosive gases when exposed to fire. These cables are colour coded to the DIN

47100 standard and offer excellent flexibility and durability.

31500712

31500212

CONSTRUCTION

Fine copper wire strands to BS EN 60228. Low

Smoke Halogen Free (LSHF) insulation, colour

coded cores twisted together with overall polyester

tape and tinned copper wire braid. Flame retardant

LSHF grey sheath.

Part No.

Cores x

mm 2

Weight

kg/km

O/D

mm

31500102 2 x 0.14 18 3.9

31500103 3 x 0.14 22 4.1

31500104 4 x 0.14 24 4.3

31500105 5 x 0.14 29 4.7

31500107 7 x 0.14 32 5.2

31500110 10 x 0.14 46 6.5

31500112 12 x 0.14 53 6.9

31500118 18 x 0.14 72 7.8

31500202 2 x 0.25 21 4.3

31500203 3 x 0.25 23 4.4

31500204 4 x 0.25 27 4.7

31500205 5 x 0.25 34 5.3

31500207 7 x 0.25 41 5.7

31500210 10 x 0.25 55 7.3

31500212 12 x 0.25 64 7.5

31500218 18 x 0.25 89 9.0

31500302 2 x 0.34 25 5.0

31500303 3 x 0.34 30 5.2

31500304 4 x 0.34 36 5.6

31500305 5 x 0.34 44 6.3

31500307 7 x 0.34 54 6.9

31500310 10 x 0.34 76 8.9

31500312 12 x 0.34 86 9.1

TECHNICAL INFORMATION

Voltage Rating: 0.14mm 2 : 300V

0.25mm 2 to 1.5mm 2 : 300/500V

Temperature Rating:

Bending Radius:

Part No.

Flexing -5°C to +70°C

Static -20°C to +80°C

Flexing 10 x cable diameter

Static 6 x cable diameter

Flame Retardant: IEC/BS EN 60332-1-2

Smoke Emission: IEC/BS EN 61034-2

Halogen Emission: IEC/BS EN 60754-1 & 2

Colour Code: DIN 47100 see page 212

Cores x

mm 2

Weight

kg/km

O/D

mm

31500502 2 x 0.5 42 5.3

31500503 3 x 0.5 49 5.6

31500504 4 x 0.5 64 6.2

31500505 5 x 0.5 79 6.9

31500507 7 x 0.5 99 7.4

31500512 12 x 0.5 142 9.8

31500702 2 x 0.75 49 5.9

31500703 3 x 0.75 64 6.4

31500704 4 x 0.75 81 7.1

31500705 5 x 0.75 106 7.7

31500707 7 x 0.75 122 8.7

31500712 12 x 0.75 187 11.0

31501002 2 x 1.0 61 6.1

31501003 3 x 1.0 82 6.8

31501004 4 x 1.0 102 7.2

31501005 5 x 1.0 119 8.4

31501007 7 x 1.0 149 9.1

31501502 2 x 1.5 76 7.1

31501503 3 x 1.5 104 7.9

31501504 4 x 1.5 117 8.4

31501505 5 x 1.5 149 9.3

31501507 7 x 1.5 188 10.4

Other sizes and numbers of cores are often available

on short delivery times, please ask for details.

CPR-Compliant Options Available

www.fscables.com | sales@fscables.com


Niltox ® LF-316 LSHF

95

Niltox ® LF-316 Screened LSHF Multipair

The Niltox LF-316 paired and screened range of Low Smoke Halogen Free (LSHF) data cables offer excellent flexibility

and durability. Identification of the cores is made easy due to the DIN 47100 colour code. The cable is screened with an

overall tinned copper wire braid offering excellent protection from electromagnetic interference.

CONSTRUCTION

Fine copper wire strands to BS EN 60228. LSHF

insulation, colour coded, two cores twisted

together to form a pair, pairs then twisted

together to form multipair cables, overall polyester

tape and overall tinned copper wire braid. Flame

retardant LSHF grey sheath.

TECHNICAL INFORMATION

Voltage Rating: 0.14mm 2 : 300V

0.25mm 2 to 0.75mm 2 : 500V

Temperature Rating:

Bending Radius:

Flexing +5°C to +70°C

Static -20°C to +70°C

7.5 x cable diameter

Flame Retardant: IEC/BS EN 60332-1-2

Smoke Emission: IEC/BS EN 61034-2

Halogen Emission: IEC/BS EN 60754-1 & 2

Colour Code: DIN 47100 see page 212

31600506

Part No.

Pairs

x mm 2

Weight

kg/km

O/D

mm

31600102 2 x 2 x 0.14 36 5.3

31600103 3 x 2 x 0.14 47 5.9

31600104 4 x 2 x 0.14 65 6.7

31600106 6 x 2 x 0.14 86 8.1

31600107 7 x 2 x 0.14 94 8.7

31600112 12 x 2 x 0.14 134 10.1

31600201 1 x 2 x 0.25 21 4.8

31600202 2 x 2 x 0.25 44 5.9

31600203 3 x 2 x 0.25 65 6.5

31600204 4 x 2 x 0.25 80 7.2

31600206 6 x 2 x 0.25 114 9.0

31600207 7 x 2 x 0.25 121 9.4

31600212 12 x 2 x 0.25 173 10.9

31600302 2 x 2 x 0.34 67 7.3

31600303 3 x 2 x 0.34 91 7.8

31600304 4 x 2 x 0.34 109 9.5

31600306 6 x 2 x 0.34 140 10.0

31600307 7 x 2 x 0.34 155 11.0

31600312 12 x 2 x 0.34 246 13.7

Part No.

Pairs

x mm 2

Weight

kg/km

O/D

mm

31600501 1 x 2 x 0.5 42 5.8

31600502 2 x 2 x 0.5 76 7.6

31600503 3 x 2 x 0.5 108 8.3

31600504 4 x 2 x 0.5 135 10.2

31600505 5 x 2 x 0.5 152 10.9

31600506 6 x 2 x 0.5 168 11.3

31600507 7 x 2 x 0.5 186 11.9

31600512 12 x 2 x 0.5 331 14.7

31600702 2 x 2 x 0.75 106 8.9

31600703 3 x 2 x 0.75 138 10.0

31600704 4 x 2 x 0.75 165 11.6

31600705 5 x 2 x 0.75 234 13.5

31600707 7 x 2 x 0.75 259 13.8

31600712 12 x 2 x 0.75 439 16.8

Other sizes and numbers of cores are often available

on short delivery times, please ask for details.

CPR-Compliant Options Available

Tel: 01727 840 841

LSHF


96

Def-Standard LSHF

Def-Standard LSHF Multicore

For installations that call for Low Smoke Halogen Free (LSHF) signal cables, the range of Def-Standard LSHF miniature

multicores are the ideal solution. Manufactured in the style of the Def Style PVC multicores on pages 110 - 112,

these cables are suitable for use in public buildings & sensitive areas as they contain no halogen emitting compounds.

Screened and unscreened options are held in stock. This cable is not suitable for direct connection to the mains.

39200206H

CONSTRUCTION

Fine tinned copper wire strands, colour coded

LSHF insulation, cores laid-up with a LSHF outer

sheath. Screened type ‘C’ has a polyester tape

with a tinned copper wire braid screen. Screened

type ‘S’ has an aluminium foil screen and tinned

copper drain wire.

TECHNICAL INFORMATION

Voltage Rating: 440V rms up to 1600Hz

Temperature Rating: 0ºC to +70ºC

Current Rating: 0.22mm 2 1amp

Nominal Conductor

Max. Resistance @ 20ºC: 0.22mm 2 - 92 ohms per km

Bending Radius: Static 7.5 x cable diameter

Flame Retardant: IEC/BS EN 60332-1-2

Smoke Emission: IEC/BS EN 61034-2

Halogen Emission: IEC/BS EN 60754-1 & 2

Colour Code: Def-Standard see page 211

Part No. Size No. of Cores Weight kg/km O/D mm

LSHF Unscreened 7/0.2mm - 0.22mm 2

Type ‘A’

39200202H 7-2-2A 2 14 3.4

39200203H 7-2-3A 3 17 3.5

39200204H 7-2-4A 4 22 3.8

39200206H 7-2-6A 6 32 5.0

39200208H 7-2-8A 8 47 5.7

39200212H 7-2-12A 12 56 6.4

39200218H 7-2-18A 18 82 7.4

39200225H 7-2-25A 25 100 8.7

39200236H 7-2-36A 36 146 9.8

LSHF Braided Screened 7/0.2mm - 0.22mm 2

Type ‘C’

39300202H 7-2-2C 2 25 3.8

39300203H 7-2-3C 3 29 4.0

39300204H 7-2-4C 4 33 4.6

39300206H 7-2-6C 6 57 5.9

39300208H 7-2-8C 8 66 6.4

39300212H 7-2-12C 12 87 7.0

39300218H 7-2-18C 18 115 8.4

39300225H 7-2-25C 25 153 9.5

39300236H 7-2-36C 36 207 10.7

LSHF Foil Screened 7/0.2mm - 0.22mm 2

Type ‘S’

39400202H 7-2-2S 2 23 3.9

39400203H 7-2-3S 3 28 4.0

39400204H 7-2-4S 4 31 4.6

39400206H 7-2-6S 6 52 5.5

39400208H 7-2-8S 8 60 6.0

39400212H 7-2-12S 12 79 6.8

39400218H 7-2-18S 18 103 7.9

39400225H 7-2-25S 25 141 8.8

39400236H 7-2-36S 36 183 10.2

Please see next page for 16/0.2mm 0.5mm 2 LSHF version

CPR-Compliant Options Available

www.fscables.com | sales@fscables.com


Def-Standard LSHF

97

Def-Standard LSHF Multicore

CONSTRUCTION

Fine tinned copper wire strands, colour coded

Low Smoke Halogen Free (LSHF) insulation, cores

laid-up with a LSHF outer sheath. Screened type

‘C’ has a polyester tape with a tinned copper wire

braid screen. Screened type ‘S’ has an aluminium

foil screen and tinned copper drain wire.

TECHNICAL INFORMATION

Voltage Rating: 440V rms up to 1600Hz

Temperature Rating: 0ºC to +70ºC

Current Rating: 0.5mm 2 2.5amps

Nominal Conductor

Max. Resistance @ 20ºC: 0.5mm 2 - 40.1 ohms per km

Bending Radius: Static 7.5 x cable diameter

Flame Retardant: IEC/BS EN 60332-1-2

Smoke Emission: IEC/BS EN 61034-2

Halogen Emission: IEC/BS EN 60754-1 & 2

Colour Code: Def-Standard see page 211

39300212

Part No. Size No. of Cores Weight kg/km O/D mm

LSHF Unscreened 16/0.2mm - 0.5mm 2

Type ‘A’

39200502H 16-2-2A 2 35 5.5

39200503H 16-2-3A 3 42 6.2

39200504H 16-2-4A 4 54 6.8

39200506H 16-2-6A 6 76 7.9

39200508H 16-2-8A 8 96 7.7

39200512H 16-2-12A 12 120 10.1

39200518H 16-2-18A 18 180 11.0

39200525H 16-2-25A 25 274 13.2

LSHF Braided Screened 16/0.2mm - 0.5mm 2

Type ‘C’

39300502H 16-2-2C 2 71 6.5

39300503H 16-2-3C 3 82 6.8

39300504H 16-2-4C 4 97 7.1

39300506H 16-2-6C 6 130 8.3

39300508H 16-2-8C 8 152 9.4

39300512H 16-2-12C 12 202 10.5

39300518H 16-2-18C 18 270 12.0

39300525H 16-2-25C 25 350 14.1

39300536H 16-2-36C 36 475 16.1

LSHF Foil Screened 16/0.2mm - 0.5mm 2

Type ‘S’

39400502H 16-2-2S 2 47 5.2

39400503H 16-2-3S 3 56 6.2

39400504H 16-2-4S 4 61 6.3

39400506H 16-2-6S 6 75 7.6

39400508H 16-2-8S 8 89 8.5

39400512H 16-2-12S 12 132 9.7

39400518H 16-2-18S 18 198 12.0

39400525H 16-2-25S 25 235 14.1

39400508H

Please see previous page for 7/0.2mm 0.22mm 2 LSHF version

CPR-Compliant Options Available

Tel: 01727 840 841

LSHF


98

Niltox ® LF-349 LSHF

Niltox ® LF-349 Steel Braided LSHF Multicore

LF-349 is a Low Smoke Halogen Free (LSHF) alternative to SY cables. The heavy black LSHF outer sheath covers a tough

galvanised steel wire braid armour, offering a high level of protection to the cores. Insulation and inner sheath are also

both LSHF which makes this cable a little less flexible than conventional PVC SY, however, offers excellent performance

in the event of a fire.

34901507

CONSTRUCTION

Fine copper wire strands to BS EN 60228 class 5,

LSHF insulation, colour coded cores up to 5 core

with the 7 core and above having black cores with

white numbers and a green/yellow earth core, grey

LSHF bedding, overall galvanised steel wire braid,

black LSHF outer sheath.

TECHNICAL INFORMATION

Voltage Rating: 300/500V

Temperature Rating:

Bending Radius:

Flexing +5°C to +70°C

Static -20°C to +70°C

10 x cable diameter

Flame Retardant: IEC/BS EN 60332-1-2

Smoke Emission: IEC/BS EN 61034-2

Halogen Emission:

IEC/BS EN 60754-1&2

34901504C

Part No. Cores x mm 2 Weight kg/km

O/D

mm

34901502C 2 x 1.5 108 8.9

34901503C 3 x 1.5 131 9.7

34901504C 4 x 1.5 163 10.5

34901505C 5 x 1.5 188 11.7

34901507 7 x 1.5 239 12.3

34902502C 2 x 2.5 152 9.9

34902503C 3 x 2.5 185 11.2

34902504C 4 x 2.5 235 13.1

34902505C 5 x 2.5 263 13.9

34902507 7 x 2.5 325 15.1

34904003C 3 x 4.0 280 12.3

34904004C 4 x 4.0 330 13.1

34904005C 5 x 4.0 462 15.5

34906003C 3 x 6.0 391 14.7

34906004C 4 x 6.0 498 16.7

34906005C 5 x 6.0 620 18.2

34910003C 3 x 10 610 17.5

34910004C 4 x 10 771 19.4

34910005C 5 x 10 928 21.7

34916003C 3 x 16 995 20.5

34916004C 4 x 16 1081 22.7

34916005C 5 x 16 1225 24.9

Colour Code:

2 core Blue Brown

3 core Blue

4 core Brown

Brown Green/Yellow

Black Grey Green/Yellow

5 core Blue Brown Black Grey Green/Yellow CPR-Compliant Options Available

www.fscables.com | sales@fscables.com


99

Signal & Control

Introduction

From simple PVC flexes to high-performance robotic

cables, the FSC range has them all!

Large stocks of the relatively conventional YY, CY,

and SY cables are held ranging from 2-50 core and

from 0.5mm² to 35mm². These are a popular choice

for many industrial and commercial installations.

Def Stans and LiYY or LiYCY are ideal where

miniature conductor sizes are needed. Stocked in

unscreened and screened versions they are colour

coded for easy identification when terminating.

Where frequent movement is needed, highly

flexible cables with special insulation and sheaths

are required. Spiral cables are ideal for some

applications whereas the HF series is specifically

designed for repetitive movement through a drag

chain or under guidance.

Give us a call to talk through your application; we

are bound to have a cable to suit.

Contents

YY 100 & 101

SY 102 & 103

LiYCY 104 & 105

LiYY 106

Miniature LiYCY 107

LiYCY TP 108 & 109

Def-Standard PVC 110 - 112

Bedded CY 113

BS5308 114 - 117

Spiral Cables 118 & 119

Robotics HF-100 & HF-100-C PUR 120 & 121

Robotics HF-120 & HF-120-C PUR 122

Robotics HF-120-C Twisted Pair 123

Robotics HF-265 PUR Encoder 124

Robotics HF-275 PUR

Servo & Feedback Cables

125

Robotic Bus Cables 126

Tel: 01727 840 841

SIGNAL & CONTROL


100

YY PVC

YY PVC Multicore

Flexibility is ensured through the use of fine copper wire stranding and pliable PVC compounds. This makes the cable

ideal for use on portable or movable equipment or where flexibility will make installation considerably easier.

A 600/1000V grade is also now available in sizes above 0.75mm² as are American UL listed versions. Where resistance to

water or oils is required, polyurethane (PUR) jackets offer excellent protection and are available on short lead times. For

Low Smoke Halogen Free (LSHF) types, please see LF-319 on pages 88 & 89.

10001507

CONSTRUCTION

Fine copper wire strands to BS EN 60228 class 5

depending on cross section. PVC insulation with

either number or colour coding. A green/yellow

earth core is normally included in cables with more

than 2 cores. Cores twisted together, grey PVC

sheath.

TECHNICAL INFORMATION

Voltage Rating: 300/500V Test 3000V

Temperature Rating:

Min. Bending Radius:

Static -20°C to +70°C

Flexing -5°C to +70°C

Static 6 x cable diameter

Flexing 15 x cable diameter

Part No.

Cores x

mm 2

Weight

kg/km

O/D

mm

Number Coded 1 2 3 4 5

10000502 2 x 0.5 33 4.9

10000503 3 x 0.5 43 5.2

10000504 4 x 0.5 46 5.7

10000505 5 x 0.5 53 6.4

10000507 7 x 0.5 75 6.6

10000512 12 x 0.5 113 8.9

10000518 18 x 0.5 167 10.7

10000521 21 x 0.5 194 11.7

10000540 40 x 0.5 347 15.5

10000702 2 x 0.75 41 5.2

10000703 3 x 0.75 54 5.7

10000704 4 x 0.75 58 6.1

10000705 5 x 0.75 69 6.7

10000707 7 x 0.75 97 7.2

10000708 8 x 0.75 109 8.6

10000710 10 x 0.75 133 9.3

10000712 12 x 0.75 151 9.9

10000718 18 x 0.75 216 11.5

10000721 21 x 0.75 263 13.8

10000725 25 x 0.75 296 14.1

10000734 34 x 0.75 392 15.9

10000741 41 x 0.75 466 16.9

10000742 42 x 0.75 496 17.6

10000750 50 x 0.75 585 19.3

10000761 61 x 0.75 693 20.9

10001002 2 x 1.0 50 5.5

10001003 3 x 1.0 60 5.9

10001004 4 x 1.0 63 6.6

10001005 5 x 1.0 81 7.1

10001007 7 x 1.0 126 7.6

10001010 10 x 1.0 157 9.9

10001012 12 x 1.0 183 10.5

Part No.

Cores x

mm 2

Weight

kg/km

O/D

mm

10001018 18 x 1.0 266 12.4

10001021 21 x 1.0 313 14.2

10001025 25 x 1.0 356 14.7

10001034 34 x 1.0 469 16.6

10001041 41 x 1.0 588 18.3

10001042 42 x 1.0 601 18.5

10001050 50 x 1.0 691 19.9

10001080 80 x 1.0 1099 24.6

10001502 2 x 1.5 64 6.2

10001503 3 x 1.5 80 6.6

10001504 4 x 1.5 99 7.3

10001505 5 x 1.5 112 7.9

10001507 7 x 1.5 150 8.9

10001510 10 x 1.5 212 11.2

10001512 12 x 1.5 250 11.7

10001514 14 x 1.5 289 12.8

10001518 18 x 1.5 362 13.9

10001521 21 x 1.5 426 15.5

10001525 25 x 1.5 515 17.2

10001532 32 x 1.5 634 18.7

10001534 34 x 1.5 671 19.3

10001542 42 x 1.5 836 20.4

10001550 50 x 1.5 973 22.6

10001561 61 x 1.5 1181 25.2

10001565 65 x 1.5 1359 26.8

10002502 2 x 2.5 96 7.6

10002503 3 x 2.5 125 8.0

10002504 4 x 2.5 152 8.8

10002505 5 x 2.5 173 9.8

10002507 7 x 2.5 238 11.9

10002512 12 x 2.5 384 14.5

10002518 18 x 2.5 559 17.4

Other core counts and sizes are available please ask for more details. Overall diameters (O/D) are approximate and for

guidance only and will vary from one manufacturer to another. If the O/D is critical please check at time of order and we

will measure it.

CPR-Compliant Options Available

www.fscables.com | sales@fscables.com


YY PVC

101

Part No.

Cores x

mm 2

Weight

kg/km

O/D

mm

10002521 21 x 2.5 737 21.5

10002525 25 x 2.5 793 22.1

10002534 34 x 2.5 1086 23.8

10002550 50 x 2.5 1579 28.9

10004003 3 x 4.0 182 9.7

10004004 4 x 4.0 235 10.6

10004005 5 x 4.0 276 11.8

10004007 7 x 4.0 358 13.0

10006003 3 x 6.0 273 11.9

10006004 4 x 6.0 337 12.8

10006005 5 x 6.0 407 14.3

10006007 7 x 6.0 498 16.7

10010004 4 x 10 532 15.8

10010005 5 x 10 675 17.9

10010007 7 x 10 894 19.5

10016004 4 x 16 849 19.2

10016005 5 x 16 1053 21.7

10016007 7 x 16 1389 23.8

10025004 4 x 25 1275 23.3

10025005 5 x 25 1580 25.9

10025007 7 x 25 2109 28.5

10035004 4 x 35 1686 27.3

10035005 5 x 35 2106 29.6

10050004 4 x 50 2534 32.1

10070004 4 x 70 3365 36.3

10095004 4 x 95 4535 41.4

10120004 4 x 120 5486 45.3

Colour Coded

10000702C 2 x 0.75 41 5.2

10000703C 3 x 0.75 54 5.7

10000704E 4 x 0.75 58 6.1

10000705E 5 x 0.75 69 6.7

10000707C 7 x 0.75 97 7.2

10000712C 12 x 0.75 151 9.9

10001002C 2 x 1.0 50 5.5

10001003C 3 x 1.0 60 5.9

10001004E 4 x 1.0 63 6.6

10001005E 5 x 1.0 81 7.1

10001007C 7 x 1.0 126 7.6

10001012C 12 x 1.0 183 10.5

Part No.

Cores x

mm 2

Weight

kg/km

O/D

mm

10001502C 2 x 1.5 64 6.2

10001503C 3 x 1.5 80 6.6

10001504E 4 x 1.5 99 7.3

10001505E 5 x 1.5 112 7.9

10001507C 7 x 1.5 150 8.9

10001512C 12 x 1.5 250 11.7

10002502C 2 x 2.5 96 7.6

10002503C 3 x 2.5 125 8.0

10002504E 4 x 2.5 152 8.8

10002505E 5 x 2.5 173 9.8

10002507C 7 x 2.5 238 11.9

10002512C 12 x 2.5 384 14.5

10004003C 3 x 4.0 260 11.9

10004004E 4 x 4.0 302 12.6

10004005E 5 x 4.0 359 13.8

10004007C 7 x 4.0 482 15.5

10006003C 3 x 6.0 319 12.8

10006004E 4 x 6.0 396 13.7

10006005E 5 x 6.0 493 15.8

10006007C 7 x 6.0 660 17.5

10010003C 3 x 10 521 16.1

10010004E 4 x 10 655 17.7

10010005E 5 x 10 798 19.8

10010007C 7 x 10 1063 21.8

10016003C 3 x 16 920 18.4

10016004E 4 x 16 1095 20.6

10016005E 5 x 16 1379 22.9

10025003C 3 x 25 1371 23.2

10025004E 4 x 25 1592 25.6

10025005E 5 x 25 2012 28.4

10035003C 3 x 35 1782 25.7

10035004E 4 x 35 2151 28.6

10035005E 5 x 35 2863 31.8

10050003C 3 x 50 2561 31.1

10050004E 4 x 50 2983 34.8

10050005E 5 x 50 3860 38.5

10070003C 3 x 70 3215 35.5

10070004E 4 x 70 4123 39.4

10070005E 5 x 70 4834 44.3

10095003C 3 x 95 4721 41.5

10095004E 4 x 95 5583 45.9

10095005E 5 x 95 6513 50.3

10120004E 4 x 120 7135 52.3

10004003E

Colour Code:

2 core Blue Brown

3 core Blue Brown Green/Yellow

4 core Brown Black Grey Green/Yellow

5 core Blue Brown Black Grey Green/Yellow

CPR-Compliant Options Available

Tel: 01727 840 841

SIGNAL & CONTROL


102

SY PVC

SY PVC Steel Braided Multicore

Where mechanical protection is called for on a flexible cable, SY is a popular choice. The tough, flexible, clear outer

sheath provides excellent abrasion resistance. Whilst the galvanised steel wire braid protects against cuts, hot swarf and

even rodents. Suitable as a supply or control cable for motors, plant, machinery and many other applications. For Low

Smoke Halogen Free (LSHF) types, please see LF-349 on page 98.

11001507

CONSTRUCTION

Fine copper wire strands to BS EN 60228 Class 5.

Black PVC insulation with white numbers or colour

coded. Cables with more than 2 cores include a

green/yellow earth, cores twisted together. Grey

PVC inner sheath, steel wire braid, clear PVC outer

sheath.

TECHNICAL INFORMATION

Voltage Rating: 300/500V Test 3000V

Temperature Rating:

Bending Radius:

Static -20°C to +70°C

Flexing -5°C to +70°C

Static 10 x cable diameter

Flexing 20 x cable diameter

Part No.

Cores x

mm 2

Weight

kg/km

O/D

mm

Number Coded 1 2 3 4 5

11000502 2 x 0.5 77 7.0

11000503 3 x 0.5 101 8.6

11000504 4 x 0.5 116 9.1

11000505 5 x 0.5 127 9.4

11000507 7 x 0.5 163 10.4

11000512 12 x 0.5 251 13.1

11000518 18 x 0.5 340 15.2

11000525 25 x 0.5 540 19.3

11000534 34 x 0.5 660 21.4

11000550 50 x 0.5 820 24.9

11000702 2 x 0.75 105 8.3

11000703 3 x 0.75 100 8.5

11000704 4 x 0.75 136 9.6

11000705 5 x 0.75 172 10.9

11000707 7 x 0.75 208 11.5

11000712 12 x 0.75 337 15.0

11000718 18 x 0.75 330 17.5

11000725 25 x 0.75 641 20.7

11000734 34 x 0.75 771 22.9

11000750 50 x 0.75 929 27.1

11001002 2 x 1.0 124 9.1

11001003 3 x 1.0 139 9.7

11001004 4 x 1.0 150 9.9

11001005 5 x 1.0 190 11.2

11001007 7 x 1.0 238 12.1

11001012 12 x 1.0 324 14.4

11001018 18 x 1.0 482 17.4

11001025 25 x 1.0 723 21.6

11001034 34 x 1.0 908 24.0

11001050 50 x 1.0 1343 28.7

Part No.

Cores x

mm 2

Weight

kg/km

O/D

mm

11001502 2 x 1.5 153 10.0

11001503 3 x 1.5 162 10.3

11001504 4 x 1.5 193 11.2

11001505 5 x 1.5 234 12.2

11001507 7 x 1.5 302 13.5

11001512 12 x 1.5 487 17.4

11001518 18 x 1.5 676 20.5

11001525 25 x 1.5 925 24.1

11001542 42 x 1.5 1424 29.6

11002502 2 x 2.5 192 11.1

11002503 3 x 2.5 237 12.2

11002504 4 x 2.5 297 13.6

11002505 5 x 2.5 365 14.8

11002507 7 x 2.5 434 15.7

11002512 12 x 2.5 727 20.9

11002518 18 x 2.5 1005 24.5

11004003 3 x 4.0 353 14.7

11004004 4 x 4.0 458 16.8

11004005 5 x 4.0 556 18.1

11004007 7 x 4.0 687 19.8

11006003 3 x 6.0 451 16.2

11006004 4 x 6.0 570 18.2

11006005 5 x 6.0 693 19.5

11006007 7 x 6.0 729 21.8

11010004 4 x 10 906 22.7

11010005 5 x 10 1077 24.5

11010007 7 x 10 1230 25.8

11016004 4 x 16 1406 27.9

11016005 5 x 16 1780 31.1

11025004 4 x 25 2058 33.8

11025005 5 x 25 2529 37.3

11035004 4 x 35 2571 36.7

11050004 4 x 50 3613 39.9

11070004 4 x 70 4893 45.6

11095004 4 x 95 6423 50.2

CPR-Compliant Options Available

www.fscables.com | sales@fscables.com


SY PVC

103

Part No.

Colour Coded

Cores x

mm 2

Weight

kg/km

O/D

mm

11000702C 2 x 0.75 105 8.3

11000703C 3 x 0.75 100 8.5

11000704E 4 x 0.75 136 9.6

11000705E 5 x 0.75 172 10.9

11000707C 7 x 0.75 208 11.5

11000712C 12 x 0.75 337 15.0

11001002C 2 x 1.0 124 9.1

11001003C 3 x 1.0 139 9.7

11001004E 4 x 1.0 150 9.9

11001005E 5 x 1.0 190 11.2

11001007C 7 x 1.0 238 12.1

11001012C 12 x 1.0 324 14.4

11001502C 2 x 1.5 153 10.0

11001503C 3 x 1.5 162 10.3

11001504E 4 x 1.5 193 11.2

11001505E 5 x 1.5 234 12.2

11001507C 7 x 1.5 302 13.5

11001512C 12 x 1.5 487 17.4

11002502C 2 x 2.5 192 11.1

11002503C 3 x 2.5 237 12.2

11002504E 4 x 2.5 297 13.6

11002505E 5 x 2.5 365 14.8

11002507C 7 x 2.5 434 15.7

11002512C 12 x 2.5 727 20.9

11004003C 3 x 4.0 353 14.7

11004004E 4 x 4.0 458 16.8

11004005E 5 x 4.0 556 18.1

11004007C 7 x 4.0 687 19.8

Part No.

Cores x

mm 2

Weight

kg/km

O/D

mm

11006003C 3 x 6.0 451 16.2

11006004E 4 x 6.0 570 18.2

11006005E 5 x 6.0 693 19.5

11006007C 7 x 6.0 729 21.8

11010003C 3 x 10 744 19.7

11010004E 4 x 10 906 22.7

11010005E 5 x 10 1077 24.5

11016003C 3 x 16 1108 22.7

11016004E 4 x 16 1406 27.9

11016005E 5 x 16 1780 31.1

11025003C 3 x 25 1681 27.6

11025004E 4 x 25 2058 33.8

11025005E 5 x 25 2529 37.3

11035003C 3 x 35 1973 32.9

11035004E 4 x 35 2621 36.7

11035005E 5 x 35 3268 41.1

11050003C 3 x 50 2731 35.7

11050004E 4 x 50 3613 39.9

11050005E 5 x 50 4367 44.3

11070003C 3 x 70 2832 42.8

11070004E 4 x 70 4893 45.6

11070005E 5 x 70 5869 51.7

11095003C 3 x 95 4996 46.4

11095004E 4 x 95 6423 50.2

11095005E 5 x 95 8162 56.9

11120004E 4 x 120 8235 56.1

11150004E 4 x 150 10324 63.2

11001504E

Colour Code:

2 core Blue Brown

3 core Blue Brown Green/Yellow

4 core Brown Black Grey Green/Yellow

5 core Blue Brown Black Grey Green/Yellow

CPR-Compliant Options Available

Tel: 01727 840 841

SIGNAL & CONTROL


104

LiYCY PVC

LiYCY PVC Screened Multicore

LiYCY has a tinned copper wire braid screen, providing protection from electromagnetic interference (EMI) and reducing

electromagnetic radiation (EMR). This can be important when trying to ensure electromagnetic compatibility (EMC). Core

identification is either number coded or colour coded.

Miniature versions with cores between 0.14mm² and 0.34mm² and unscreened types with colour coding to DIN 47100

are shown on pages 106 & 107.

With the cores twisted into pairs and overall screens known as LiYCY-TP, part numbers starting 325 please see pages

108 & 109; or twisted pairs without a screen LiYY-TP - part numbers starting 305.

For Low Smoke Halogen Free (LSHF) types, please see the LF-315 & LF 329 range, page 94 and pages 90 & 91 respectively.

32001503C

CONSTRUCTION

Fine copper wire strands to BS EN 60228. PVC

insulation colour or number coded. Cores twisted

together with overall polyester tape and tinned

copper wire braid. Grey PVC outer sheath.

TECHNICAL INFORMATION

CORE IDENTIFICATION

Number Coded:

Colour Coded:

Voltage Rating: 0.5mm² - 1.5mm 2 : Working 300V

2.5mm² - 16mm 2 :

Working 500V

Temperature Rating: Static -20°C to +70°C Flexing -5°C to +70°C

Min. Bending Radius: Static 6 x cable diameter Flexing 15 x cable diameter

Conductor Stranding: Flexible to BS EN 60228 Class 5.

0.5mm 2 - 35mm 2 . Black cores

with white numbers + G/Y on

cables with more than 2 cores.

Between 2 and 5 cores to BS

7671 HD 308 S2

Part No. Cores x mm 2 Weight kg/km O/D mm

Colour Coded

32000702C 2 x 0.75 56 6.7

32000703C 3 x 0.75 70 7.1

32000704E 4 x 0.75 95 7.6

32000705E 5 x 0.75 130 8.2

32001002C 2 x 1.0 84 7.7

32001003C 3 x 1.0 110 8.5

32001004E 4 x 1.0 130 9.2

32001005E 5 x 1.0 156 9.9

32001502C 2 x 1.5 97 8.1

32001503C 3 x 1.5 125 8.9

32001504E 4 x 1.5 165 9.7

32001505E 5 x 1.5 193 10.5

32002502C 2 x 2.5 148 10.1

32002503C 3 x 2.5 188 10.6

32002504E 4 x 2.5 236 11.6

32002505E 5 x 2.5 270 12.6

32004003C 3 x 4.0 250 12.4

32004004E 4 x 4.0 302 13.5

32004005E 5 x 4.0 370 14.8

Colour Code:

2 core Blue Brown

3 core Blue

4 core Brown

5 core Blue

Brown Green/Yellow

Black Grey Green/Yellow

Brown Black Grey Green/Yellow

CPR-Compliant Options Available

www.fscables.com | sales@fscables.com


LiYCY PVC

105

Part No. Cores x mm 2 Weight kg/km O/D mm

Number Coded 1 2 3 4 5

32000502 2 x 0.5 42 5.4

32000503 3 x 0.5 51 5.8

32000504 4 x 0.5 61 6.5

32000505 5 x 0.5 80 6.9

32000507 7 x 0.5 98 7.8

32000512 12 x 0.5 156 10.1

32000518 18 x 0.5 215 11.8

32000525 25 x 0.5 314 14.4

32000702 2 x 0.75 56 6.7

32000703 3 x 0.75 70 7.1

32000704 4 x 0.75 95 7.6

32000705 5 x 0.75 130 8.2

32000707 7 x 0.75 168 8.9

32000712 12 x 0.75 232 12.0

32000718 18 x 0.75 315 13.9

32000725 25 x 0.75 418 16.5

32001002 2 x 1.0 84 7.7

32001003 3 x 1.0 110 8.5

32001004 4 x 1.0 130 9.2

32001005 5 x 1.0 156 9.9

32001007 7 x 1.0 192 10.7

32001012 12 x 1.0 265 13.7

32001018 18 x 1.0 380 15.9

32001025 25 x 1.0 475 17.5

32001502 2 x 1.5 97 8.1

32001503 3 x 1.5 125 8.9

32001504 4 x 1.5 165 9.7

32001505 5 x 1.5 193 10.5

32001507 7 x 1.5 245 11.3

32001512 12 x 1.5 365 14.5

32001518 18 x 1.5 553 16.9

32001525 25 x 1.5 720 20.1

32001530 30 x 1.5 776 20.7

32002502 2 x 2.5 148 10.1

32002503 3 x 2.5 188 10.6

32002504 4 x 2.5 236 11.6

32002505 5 x 2.5 270 12.6

32002507 7 x 2.5 340 13.7

32002512 12 x 2.5 585 18.5

32002518 18 x 2.5 725 19.7

32004003 3 x 4.0 250 12.4

32004004 4 x 4.0 302 13.5

32004005 5 x 4.0 370 14.8

32004007 7 x 4.0 473 16.1

32006003 3 x 6.0 285 13.9

32006004 4 x 6.0 412 15.2

32006005 5 x 6.0 505 16.7

32010004 4 x 10 620 20.8

32010005 5 x 10 796 22.9

32016004 4 x 16 1090 23.2

32016005 5 x 16 2070 25.6

CPR-Compliant Options Available

32000707

Tel: 01727 840 841

SIGNAL & CONTROL


106

LiYY PVC Multicore

LiYY Miniature Signal Cable with DIN 47100

Flexibility is ensured through the use of fine copper wire stranding and pliable PVC compounds. This makes the cable

ideal for use on portable or movable equipment or where flexibility will make installation considerably easier. Large sizes

are also available on short lead times as are American UL listed versions. Where resistance to water or oils is required,

polyurethane (PUR) jackets offer excellent protection and are available on short lead times.

30000325

CONSTRUCTION

Fine copper wire strands to BS EN 60228 class 5 or

class 6 depending on cross section. PVC insulation

with DIN 47100 colour coding. Cores twisted

together, grey PVC sheath.

TECHNICAL INFORMATION

Voltage Rating: 0.14mm 2 - 0.34mm 2 :

Working 250V

0.5mm 2 and above:

Working 300/500V

Temperature Rating:

Min. Bending Radius:

Static -20°C to +70°C

Flexing -5°C to +70°C

Static 6 x cable diameter

Flexing 15 x cable diameter

Part No.

Cores x

mm 2

Weight

kg/km

O/D

mm

30000102 2 x 0.14 12 3.3

30000103 3 x 0.14 15 3.5

30000104 4 x 0.14 17 3.7

30000105 5 x 0.14 22 4.0

30000107 7 x 0.14 26 4.7

30000112 12 x 0.14 43 5.7

30000118 18 x 0.14 65 7.2

30000121 21 x 0.14 79 7.5

30000125 25 x 0.14 93 8.1

30000132 32 x 0.14 112 8.8

30000140 40 x 0.14 132 9.6

30000152 52 x 0.14 177 10.9

30000161 61 x 0.14 204 11.6

30000202 2 x 0.25 25 3.7

30000203 3 x 0.25 29 3.9

30000204 4 x 0.25 31 4.2

30000205 5 x 0.25 38 4.6

30000207 7 x 0.25 48 5.3

30000212 12 x 0.25 75 7.1

30000218 18 x 0.25 110 8.2

30000221 21 x 0.25 128 8.5

30000225 25 x 0.25 146 9.8

30000232 32 x 0.25 186 10.7

30000240 40 x 0.25 207 11.5

30000252 52 x 0.25 258 12.8

30000261 61 x 0.25 324 13.9

30000302 2 x 0.34 28 4.4

30000303 3 x 0.34 30 4.6

Part No.

Cores x

mm 2

Weight

kg/km

O/D

mm

30000304 4 x 0.34 40 4.9

30000305 5 x 0.34 44 5.6

30000307 7 x 0.34 60 6.2

30000312 12 x 0.34 88 8.1

30000318 18 x 0.34 135 9.7

30000321 21 x 0.34 151 10.4

30000325 25 x 0.34 181 11.5

30000332 32 x 0.34 223 12.4

30000340 40 x 0.34 266 13.5

30000352 52 x 0.34 337 15.5

30000361 61 x 0.34 392 16.5

30000502 2 x 0.5 31 4.9

30000503 3 x 0.5 35 5.2

30000504 4 x 0.5 42 5.7

30000505 5 x 0.5 49 6.2

30000507 7 x 0.5 73 7.2

30000512 12 x 0.5 130 9.2

30000518 18 x 0.5 166 11.3

30000521 21 x 0.5 185 13.1

30000525 25 x 0.5 250 13.4

30000532 32 x 0.5 291 14.7

30000540 40 x 0.5 345 16.1

30000552 52 x 0.5 454 19.7

30000561 61 x 0.5 536 20.4

The cables above are colour coded to DIN 47100. This colour code can be

found on page 212. Other core counts and sizes are available please ask for

more details. Overall diameters (O/D) are approximate and for guidance only

and will vary from one manufacturer to another. If the O/D is critical please

check at time of order and we will measure it.

CPR-Compliant Options Available

www.fscables.com | sales@fscables.com


Miniature LiYCY PVC 250V

107

Miniature LiYCY PVC

Miniature LiYCY has a tinned copper wire braid screen, providing protection from electromagnetic interference (EMI)

and reducing electromagnetic radiation (EMR). Larger core sizes over 0.5mm² are also available number coded or colour

coded on pages 104 & 105.

These cables are available unscreened type LiYY with part numbers starting 300 please see previous page, or with the

cores twisted into pairs and overall screens known as LiYCY-TP, part numbers starting 325 please see pages 108 & 109;

or twisted pairs without a screen LiYY-TP - part numbers starting 305.

For Low Smoke Halogen Free (LSHF) types, please see the LF-315 & LF 329 range, page 94 and pages 90 & 91 respectively.

CONSTRUCTION

Fine copper wire strands to BS EN 60228. PVC

insulation colour coded to DIN 47100. Cores

twisted together with overall polyester tape and

tinned copper wire braid. Grey PVC sheath.

CORE IDENTIFICATION

Colour Coded to DIN 47100.

32000325F

TECHNICAL INFORMATION

Voltage Rating: Working 250V

Temperature Rating: Static -20°C to +70°C Flexing -5°C to +70°C

Min. Bending Radius: Static 6 x cable diameter Flexing 15 x cable diameter

Conductor Stranding: Flexible to BS EN 60228

Part No.

Cores x

mm 2

Weight

kg/km

O/D

mm

32000101F 1 x 0.14 16 3.6

32000102F 2 x 0.14 20 3.8

32000103F 3 x 0.14 25 4.0

32000104F 4 x 0.14 30 4.3

32000105F 5 x 0.14 36 4.6

32000106F 6 x 0.14 40 5.0

32000107F 7 x 0.14 41 5.2

32000108F 8 x 0.14 44 5.6

32000110F 10 x 0.14 56 6.3

32000112F 12 x 0.14 60 6.4

32000114F 14 x 0.14 65 6.7

32000116F 16 x 0.14 81 7.2

32000118F 18 x 0.14 93 7.6

32000121F 21 x 0.14 103 8.3

32000124F 24 x 0.14 117 9.0

32000125F 25 x 0.14 120 9.0

32000127F 27 x 0.14 124 9.1

32000130F 30 x 0.14 136 9.4

32000136F 36 x 0.14 160 10.0

32000140F 40 x 0.14 170 10.3

32000144F 44 x 0.14 186 11.1

32000152F 52 x 0.14 200 11.5

32000161F 61 x 0.14 250 12.1

Part No.

Cores x

mm 2

Weight

kg/km

O/D

mm

32000201F 1 x 0.25 17 3.7

32000202F 2 x 0.25 30 4.5

32000203F 3 x 0.25 37 5.1

32000204F 4 x 0.25 44 5.2

32000205F 5 x 0.25 51 5.7

32000206F 6 x 0.25 55 6.1

32000207F 7 x 0.25 60 6.4

32000208F 8 x 0.25 77 7.1

32000210F 10 x 0.25 93 8.1

32000212F 12 x 0.25 104 8.4

32000214F 14 x 0.25 115 8.7

32000216F 16 x 0.25 132 8.9

32000218F 18 x 0.25 137 9.4

32000221F 21 x 0.25 173 10.4

32000224F 24 x 0.25 184 11.4

32000225F 25 x 0.25 190 11.5

32000227F 27 x 0.25 198 11.6

32000230F 30 x 0.25 212 11.9

32000236F 36 x 0.25 238 12.7

32000240F 40 x 0.25 260 13.1

32000244F 44 x 0.25 290 14.3

32000252F 52 x 0.25 333 14.9

32000261F 61 x 0.25 382 15.8

Part No.

Cores x

mm 2

Weight

kg/km

O/D

mm

32000302F 2 x 0.34 33 5.0

32000303F 3 x 0.34 42 5.4

32000304F 4 x 0.34 49 5.8

32000305F 5 x 0.34 59 6.1

32000306F 6 x 0.34 64 6.6

32000307F 7 x 0.34 69 6.7

32000308F 8 x 0.34 84 7.4

32000310F 10 x 0.34 106 8.5

32000312F 12 x 0.34 119 8.7

32000314F 14 x 0.34 132 9.1

32000316F 16 x 0.34 146 9.6

32000318F 18 x 0.34 188 10.1

32000321F 21 x 0.34 193 10.9

32000325F 25 x 0.34 213 12.0

32000327F 27 x 0.34 232 12.3

32000330F 30 x 0.34 253 12.7

32000336F 36 x 0.34 292 13.6

32000340F 40 x 0.34 318 14.0

32000352F 52 x 0.34 400 15.8

32000361F 61 x 0.34 454 16.6

CPR-Compliant Options Available

Tel: 01727 840 841

SIGNAL & CONTROL


108

LiYCY-TP PVC

LiYCY-TP PVC Screened Paired Cables

Popular as a European alternative to the American style data cables, LiYCY-TP has the cores twisted into pairs to

reduce cross talk. The DIN 47100 colour code makes it easy to identify each conductor. The effects of electromagnetic

interference (EMI) are also minimised by the use of an overall tinned copper wire braid screen. Used extensively for signal

& data transmission where flexibility is important LiYCY-TP is designed for fixed or occasional movement although the

cable construction makes installation and routing through confined spaces simple.

32500506F

CONSTRUCTION

Plain copper wire conductors to BS EN 60228, PVC

insulation, cores twisted in pairs, polyester tape,

overall tinned copper wire braid, grey PVC sheath.

TECHNICAL INFORMATION

Voltage Rating:

≤ 0.34mm² = 300V

≥ 0.5mm² = 300/500V

Conductor Stranding: Stranded to BS EN 60228 class 5

or class 6 for 0.14mm 2

Temperature Rating:

Bending Radius:

Static -30°C to +70°C

Flexing -5 to +70°C

Colour code: DIN 47100

Static 5 x overall diameter

Flexing 10 x overall diameter

DIN 47100 EUROPEAN COLOUR CODES

The DIN 47100 standard specifies the core colour for up to 44 cores. Above this, it is usual practice to repeat the

colours. The first colour is the colour of the base insulation and the second colour is that of either a longitudinal

stripe or printed rings.

1 White

2 Brown

3 Green

4 Yellow

5 Grey

6 Pink

7 Blue

8 Red

9 Black

10 Violet

11 Grey/Pink

12 Red/Blue

13 White/Green

14 Brown/Green

15 White/Yellow

16 Yellow/Brown

17 White/Grey

18 Grey/Brown

19 White/Pink

20 Pink/Brown

21 White/Blue

22 Brown/Blue

23 White/Red

24 Brown/Red

25 White/Black

26 Brown/Black

27 Grey/Green

28 Yellow/Grey

29 Pink/Green

30 Yellow/Pink

31 Green/Blue

32 Yellow/Blue

33 Green/Red

34 Yellow/Red

35 Green/Black

36 Yellow/Black

37 Grey/Blue

38 Pink/Blue

39 Grey/Red

40 Pink/Red

41 Grey/Black

42 Pink/Black

43 Blue/Black

44 Red/Black

CPR-Compliant Options Available

www.fscables.com | sales@fscables.com


LiYCY-TP PVC

109

Part No. Pairs x mm 2 Weight

kg/km

O/D

mm

32500102F 2 x 2 x 0.14 42 5.4

32500103F 3 x 2 x 0.14 51 6.0

32500104F 4 x 2 x 0.14 58 6.5

32500105F 5 x 2 x 0.14 77 7.2

32500106F 6 x 2 x 0.14 86 7.6

32500107F 7 x 2 x 0.14 88 7.7

32500108F 8 x 2 x 0.14 104 8.2

32500110F 10 x 2 x 0.14 128 9.0

32500112F 12 x 2 x 0.14 142 9.5

32500114F 14 x 2 x 0.14 160 10.1

32500116F 16 x 2 x 0.14 156 10.6

32500118F 18 x 2 x 0.14 178 11.3

32500120F 20 x 2 x 0.14 195 11.6

32500124F 24 x 2 x 0.14 239 12.5

32500125F 25 x 2 x 0.14 243 12.9

32500126F 26 x 2 x 0.14 249 13.1

32500130F 30 x 2 x 0.14 287 13.5

32500132F 32 x 2 x 0.14 298 13.6

32500134F 34 x 2 x 0.14 321 14.6

32500136F 36 x 2 x 0.14 330 14.7

32500140F 40 x 2 x 0.14 372 15.5

32500144F 44 x 2 x 0.14 385 16.2

32500146F 46 x 2 x 0.14 433 16.5

32500150F 50 x 2 x 0.14 450 17.5

32500202F 2 x 2 x 0.25 47 6.2

32500203F 3 x 2 x 0.25 58 6.7

32500204F 4 x 2 x 0.25 75 7.5

32500205F 5 x 2 x 0.25 90 8.1

32500206F 6 x 2 x 0.25 101 8.5

32500207F 7 x 2 x 0.25 123 9.0

32500208F 8 x 2 x 0.25 130 9.4

32500210F 10 x 2 x 0.25 168 10.3

32500212F 12 x 2 x 0.25 196 10.9

32500214F 14 x 2 x 0.25 218 12.1

32500216F 16 x 2 x 0.25 221 12.5

32500218F 18 x 2 x 0.25 250 13.4

32500220F 20 x 2 x 0.25 278 13.7

32500224F 24 x 2 x 0.25 334 14.6

32500225F 25 x 2 x 0.25 337 15.2

32500226F 26 x 2 x 0.25 346 15.8

32500230F 30 x 2 x 0.25 375 16.6

32500232F 32 x 2 x 0.25 403 16.9

32500234F 34 x 2 x 0.25 412 17.5

32500236F 36 x 2 x 0.25 421 17.9

32500240F 40 x 2 x 0.25 489 18.4

32500244F 44 x 2 x 0.25 508 19.1

32500246F 46 x 2 x 0.25 540 19.4

32500250F 50 x 2 x 0.25 640 20.5

Part No. Pairs x mm 2 Weight

kg/km

O/D

mm

32500302F 2 x 2 x 0.34 65 7.1

32500303F 3 x 2 x 0.34 87 7.8

32500304F 4 x 2 x 0.34 115 8.5

32500305F 5 x 2 x 0.34 121 9.4

32500306F 6 x 2 x 0.34 139 9.9

32500307F 7 x 2 x 0.34 149 10.1

32500308F 8 x 2 x 0.34 165 10.9

32500310F 10 x 2 x 0.34 232 12.2

32500312F 12 x 2 x 0.34 239 13.3

32500314F 14 x 2 x 0.34 248 13.6

32500316F 16 x 2 x 0.34 267 14.6

32500318F 18 x 2 x 0.34 296 15.7

32500321F 21 x 2 x 0.34 308 16.3

32500325F 25 x 2 x 0.34 410 18.1

32500330F 30 x 2 x 0.34 451 19.2

32500334F 34 x 2 x 0.34 525 20.3

32500340F 40 x 2 x 0.34 623 21.6

32500344F 44 x 2 x 0.34 648 22.4

32500350F 50 x 2 x 0.34 714 23.8

32500502F 2 x 2 x 0.50 102 7.8

32500503F 3 x 2 x 0.50 135 8.4

32500504F 4 x 2 x 0.50 159 9.5

32500505F 5 x 2 x 0.50 168 9.9

32500506F 6 x 2 x 0.50 210 11.3

32500508F 8 x 2 x 0.50 268 12.2

32500510F 10 x 2 x 0.50 315 13.6

32500512F 12 x 2 x 0.50 355 14.4

32500516F 16 x 2 x 0.50 475 16.8

32500520F 20 x 2 x 0.50 532 18.5

32500525F 25 x 2 x 0.50 623 20.2

32500532F 32 x 2 x 0.50 810 22.5

32500702F 2 x 2 x 0.75 109 8.5

32500703F 3 x 2 x 0.75 142 9.4

32500704F 4 x 2 x 0.75 179 10.2

32500705F 5 x 2 x 0.75 218 11.6

32500706F 6 x 2 x 0.75 247 12.2

32500708F 8 x 2 x 0.75 306 13.5

32500710F 10 x 2 x 0.75 356 15.2

32500712F 12 x 2 x 0.75 410 16.5

32500716F 16 x 2 x 0.75 550 19.0

32500720F 20 x 2 x 0.75 686 21.3

32500725F 25 x 2 x 0.75 810 22.9

32501002F 2 x 2 x 1.0 125 9.2

32501003F 3 x 2 x 1.0 165 10.3

32501004F 4 x 2 x 1.0 220 11.1

32501502F 2 x 2 x 1.5 172 10.3

32501503F 3 x 2 x 1.5 231 12.4

32501504F 4 x 2 x 1.5 270 13.7

32500212F

CPR-Compliant Options Available

Tel: 01727 840 841

SIGNAL & CONTROL


110

Def-Standard PVC

Def-Standard PVC Multicore

Originally developed for military use, these cables are now widely used commercially and within the industry. They

offer compact sizing, high working voltage and a large range of sizes to suit most situations. Applications include data

processing, information transfer, process control and security as well as many industrial uses.

A robust and economical choice which can also be oversheathed or armoured for duct installation or direct burial. These

cables should not be used as mains connection cables.

39200206

CONSTRUCTION

Unscreened type ‘A’ has fine tinned copper wire strands, colour coded PVC insulation, cores twisted together,

polyester tape, PVC outer sheath.

Screened type ‘C’ has an overall polyester tape with tinned copper wire braid screen.

Screened type ‘S’ has an overall aluminium/polyester foil screen and tinned copper drain wire.

Duct grade versions have a heavy duty black LDPE sheath over the standard PVC sheath.

Armoured versions use the duct grade cable above as a base, applying galvanised steel wires around the cable

with an additional heavy LDPE black jacket.

Normally packed on 100m, 500m or 1000m spools, cables can also be cut to length when required.

For colour codes up to 36 cores see page 211.

TECHNICAL INFORMATION

Voltage Rating: 0.055mm 2 250V rms up to 1600Hz

0.22mm 2 ,0.5mm 2

440V rms up to 1600Hz

Temperature Rating:

Bending Radius:

0ºC to +70ºC

Static 7.5 cable diameter

Current Rating: 0.055mm 2 0.25 amps 0.22mm 2 1 amp 0.5mm 2 2.5 amps

Nominal Conductor

Max. Resistance @ 20ºC: 0.055mm 2 384 Ohm/km 0.22mm 2 92 Ohm/km 0.5mm 2 40.1 Ohm/km

Part No. Size No. of Cores Weight kg/km O/D mm

Unscreened 7/0.1mm - 0.055mm 2

Type ‘A’

39200102 7-1-2A 2 7 2.5

39200103 7-1-3A 3 8 2.6

39200104 7-1-4A 4 10 2.8

39200106 7-1-6A 6 14 3.3

39200109 7-1-9A 9 18 3.9

39200112 7-1-12A 12 24 4.3

39200115 7-1-15A 15 27 4.5

39200118 7-1-18A 18 32 5.4

39200125 7-1-25A 25 42 5.8

39200136 7-1-36A 36 63 6.4

39200150 7-1-50A 50 76 7.3

Braid Screen 7/0.1mm - 0.055mm 2

Type ‘C’

39300102 7-1-2C 2 9 3.0

39300103 7-1-3C 3 11 3.2

39300104 7-1-4C 4 17 3.4

39300106 7-1-6C 6 22 3.8

39300108 7-1-8C 8 25 4.2

39300109 7-1-9C 9 27 4.4

39300112 7-1-12C 12 44 4.6

39300115 7-1-15C 15 46 5.4

39300118 7-1-18C 18 54 5.8

39300125 7-1-25C 25 64 6.6

39300136 7-1-36C 36 83 7.2

39300150 7-1-50C 50 114 8.3

CPR-Compliant Options Available

www.fscables.com | sales@fscables.com


Def-Standard PVC

111

Part No. Size No. of Cores Weight kg/km O/D mm

Unscreened 7/0.2mm - 0.22mm 2

Type ‘A’

39200202 7-2-2A 2 14 3.4

39200203 7-2-3A 3 17 3.5

39200204 7-2-4A 4 22 3.8

39200206 7-2-6A 6 32 5.0

39200208 7-2-8A 8 47 5.7

39200212 7-2-12A 12 56 6.4

39200218 7-2-18A 18 82 7.4

39200220 7-2-20A 20 90 7.8

39200225 7-2-25A 25 100 8.7

39200236 7-2-36A 36 146 9.8

Unscreened Duct 7/0.2mm - 0.22mm 2

Type ‘A’

39200206D 7-2-6A 6 52 7.2

39200208D 7-2-8A 8 56 8.1

39200212D 7-2-12A 12 68 8.9

Foil Screened Duct 7/0.2mm - 0.22mm 2

Type ‘S’

39400206D 7-2-6S 6 53 7.5

39400208D 7-2-8S 8 58 8.6

39400212D 7-2-12S 12 72 9.6

Braid Screen 7/0.2mm - 0.22mm 2

Type ‘C’

39300202 7-2-2C 2 25 3.8

39300203 7-2-3C 3 29 4.0

39300204 7-2-4C 4 33 4.6

39300206 7-2-6C 6 57 5.9

39300208 7-2-8C 8 66 6.4

39300212 7-2-12C 12 87 7.0

39300215 7-2-15C 15 105 7.6

39300218 7-2-18C 18 115 8.4

39300220 7-2-20C 20 124 8.6

39300225 7-2-25C 25 153 9.5

39300236 7-2-36C 36 207 10.7

Foil Screened 7/0.2mm - 0.22mm 2

Type ‘S’

39400202 7-2-2S 2 23 3.9

39400203 7-2-3S 3 28 4.0

39400204 7-2-4S 4 31 4.6

39400206 7-2-6S 6 52 5.5

39400208 7-2-8S 8 60 6.0

39400212 7-2-12S 12 79 6.8

39400218 7-2-18S 18 103 7.9

39400225 7-2-25S 25 141 8.8

39400236 7-2-36S 36 175 10.5

39300212

Part No.

Size

Weight

kg/km

O/D

mm

Armoured Unscreened Def-Stan Cable Type A

39200206A 7-2-6A 328 10.9

39200208A 7-2-8A 342 11.8

39200212A 7-2-12A 356 12.6

Part No.

Size

Weight

kg/km

O/D

mm

Armoured Foil Screened Def-Stan Type S

39400206A 7-2-6S 342 11.2

39400208A 7-2-8S 358 12.3

39400212A 7-2-12S 372 13.3

Please see next page for 16/0.2mm 0.5mm 2 PVC version

Duct Grade

SWA

CPR-Compliant Options Available

Tel: 01727 840 841

SIGNAL & CONTROL


112

Def-Standard PVC

Def-Standard PVC Multicore

39400508

CONSTRUCTION

Unscreened type ‘A’ has fine tinned copper wire strands, colour coded PVC insulation, cores twisted together,

PVC outer sheath.

Screened type ‘C’ has an overall polyester tape with tinned copper wire braid screen.

Screened type ‘S’ has an overall aluminium/polyester foil screen and tinned copper drain wire.

Normally packed on 100m, 500m or 1000m spools, cables can also be cut to length when required.

For colour codes up to 36 cores see page 211.

Part No. Size No. of Cores Weight kg/km O/D mm

Unscreened 16/0.2mm - 0.5mm 2

Type ‘A’

39200502 16-2-2A 2 35 5.5

39200503 16-2-3A 3 42 6.2

39200504 16-2-4A 4 54 6.8

39200506 16-2-6A 6 76 7.9

39200508 16-2-8A 8 88 7.7

39200512 16-2-12A 12 120 10.1

39200518 16-2-18A 18 180 11.0

39200525 16-2-25A 25 265 13.2

39200536 16-2-36A 36 341 14.1

Braid Screen 16/0.2mm - 0.5mm 2

Type ‘C’

39300502 16-2-2C 2 71 6.5

39300503 16-2-3C 3 82 6.8

39300504 16-2-4C 4 97 7.1

39300506 16-2-6C 6 130 8.3

39300508 16-2-8C 8 152 9.4

39300512 16-2-12C 12 202 10.5

39300518 16-2-18C 18 270 12.0

39300525 16-2-25C 25 350 14.1

39300536 16-2-36C 36 475 16.1

Foil Screen Cored or Paired 16/0.2mm - 0.5mm 2

Type ‘S’

39400502 16-2-2S 2 47 5.2

39400503 16-2-3S 3 56 6.2

39400504 16-2-4S 4 61 6.3

39400506 16-2-6S 6 75 7.6

39400508 16-2-8S 8 89 8.5

39400512 16-2-12S 12 132 9.7

39400518 16-2-18S 18 198 12.0

39400525 16-2-25S 25 269 14.1

39400536 16-2-36S 36 387 15.9

CPR-Compliant Options Available

www.fscables.com | sales@fscables.com


CY PVC

113

CY PVC Bedded Screened Multicore

Protecting signals from electromagnetic interference (EMI) or reducing electromagnetic radiation (EMR) from supply

cables has substantially increased the need for screened multicore cables. Fine copper wire strands insulated with PVC

and combined with pliable PVC inner and outer sheaths ensure excellent flexibility, while the tinned copper wire braid

forms an effective screen.

Clear white numbering on black cores enables fast ‘right first time’ termination, vital when working with large numbers

of cores or under artificial lighting which may distort core colours. CY has many uses including general wiring in machine

tool applications especially in conjunction with PLC or microprocessor controlled manufacturing operations where signal

interference could cause major problems.

Also used as a supply cable where circumstances result in power and data cables being run in close proximity to each

other. In these cases, EMR can be significantly reduced. Not to be confused with SY which has a steel wire braid

normally of much lower coverage.

CONSTRUCTION

Fine copper wire strands to BS EN 60228 Class 5.

Black PVC insulation with white numbers, a green/

yellow earth conductor in cables with more than 2

cores. (Colour coded versions also available). Cores

twisted together. Grey PVC inner sheath, tinned

copper wire braid, clear PVC outer sheath.

TECHNICAL INFORMATION

Voltage Rating: 300/500V

Temperature Rating:

Bending Radius:

Static -20°C to +70°C

Flexing -5°C to +70°C

Static 10 x cable diameter

Flexing 20 x cable diameter

12001007

Part No.

Cores x

mm 2

Weight

kg/km

O/D

mm

Number Coded 1 2 3 4 5

12000502 2 x 0.5 91 6.8

12000503 3 x 0.5 102 7.4

12000504 4 x 0.5 114 7.9

12000505 5 x 0.5 126 8.6

12000507 7 x 0.5 155 9.2

12000512 12 x 0.5 213 11.6

12000518 18 x 0.5 338 13.4

12000525 25 x 0.5 406 15.5

12000702 2 x 0.75 102 7.2

12000703 3 x 0.75 118 7.7

12000704 4 x 0.75 134 8.3

12000705 5 x 0.75 158 8.9

12000707 7 x 0.75 183 9.7

12000712 12 x 0.75 263 12.1

12000718 18 x 0.75 393 15.3

12000725 25 x 0.75 544 16.8

12001002 2 x 1.0 117 7.6

12001003 3 x 1.0 134 8.1

12001004 4 x 1.0 154 8.6

12001005 5 x 1.0 182 9.7

12001007 7 x 1.0 202 10.5

12001012 12 x 1.0 346 13.4

12001018 18 x 1.0 476 15.6

12001025 25 x 1.0 644 18.1

12001041 41 x 1.0 1008 22.1

Part No.

Cores x

mm 2

Weight

kg/km

O/D

mm

12001502 2 x 1.5 142 8.6

12001503 3 x 1.5 165 9.1

12001504 4 x 1.5 189 10.1

12001505 5 x 1.5 223 10.6

12001507 7 x 1.5 268 11.5

12001512 12 x 1.5 441 15.1

12001518 18 x 1.5 626 17.4

12002503 3 x 2.5 214 10.4

12002504 4 x 2.5 258 11.3

12002505 5 x 2.5 306 12.9

12002507 7 x 2.5 422 13.9

12004004 4 x 4.0 411 13.5

12004005 5 x 4.0 482 14.8

12006004 4 x 6.0 533 15.9

12006005 5 x 6.0 657 17.4

12010004 4 x 10 932 19.1

12010005 5 x 10 1085 22.6

Colour Coded

12016004E 4 x 16 1195 22.3

12025004E 4 x 25 1918 32.5

12035004E 4 x 35 2516 35.6

12050004E 4 x 50 3374 38.7

12070004E 4 x 70 3819 43.8

12095004E 4 x 95 5859 47.9

12120004E 4 x 120 7351 58.2

Colour Code:

4 core Brown

Black Grey Green/Yellow

CPR-Compliant Options Available

Tel: 01727 840 841

SIGNAL & CONTROL


114

BS 5308

(BS 5308 Part 1 Type 1) Unarmoured PVC Instrumentation Cable

Originally developed for process control and communications, BS 5308 is now widely used in other industrial and

commercial applications. Available with collective aluminium tape (CAT) screening or individual and collective aluminium

tape (ICAT) screens to prevent electrical interference and crosstalk. These cables are suitable for fixed installation where

the risk of mechanical damage is minimal.

CONSTRUCTION

Type: CAT – Collective Aluminium Tape Screen

Plain annealed copper wire conductors to BS EN 60228, class 2

or 5, PE insulation, cores twisted into pairs, overall aluminium/

polyester foil screen and 0.5mm² tinned copper drain wire, PVC

sheath – black or blue.**

Type: ICAT – Individual & Collective Aluminium Tape Screen

Plain annealed copper wire conductors to BS EN 60228, class 2

or 5, PE insulation, cores twisted into pairs, each pair aluminium/

polyester foil screen and 0.5mm² tinned copper drain wire, units

laid up, collective aluminium/ polyester foil screen and 0.5mm²

tinned copper drain wire, PVC sheath – black or blue.**

Pair Identification:

CAT: Cables up to 50 pair are colour coded in accordance with BS

5308 pt 1, appendix A, see page 213. Two pair cables are twisted

as a quad and coloured black, blue, green, brown.

ICAT: Each pair black, blue and numbered cores or tapes.

TECHNICAL INFORMATION

Voltage Rating:

Temperature Rating:

Conductor Stranding:

L/R Ratio:

300V

0.6/1kV versions can be made to order.

+65°C (minimum 0°C for installation)

BS EN 60228 Class 2 or 5 plain

copper conductors

0.5mm² & 0.75mm² = 25 µH/Ohm

1.5mm² = 40 µH/Ohm

Flame Retardant: IEC/BS EN 60332-1-2

Manufactured

Generally To: PAS 5308 Part 1

5311O15100 Part No. Pairs x mm 2 Stranding

Condusctor

mm

Screen

Type

Colour

Weight

kg/km

O/D

mm*

Cap.

pF/m

Conductor

Resistance

Ohms/Km

Part 1, Type 1 - PE Insulation, Unarmoured, Collective Aluminium Tape Screen, PVC Sheath

5311O05010 1 x 2 x 0.5 16/0.2 CAT Black 54 6.8 115 39.7

5311O05020 2 x 2 x 0.5 16/0.2 CAT Black 75 7.7 115 39.7

5311O05050 5 x 2 x 0.5 16/0.2 CAT Black 187 12.9 75 39.7

5311O05100 10 x 2 x 0.5 16/0.2 CAT Black 310 17.0 75 39.7

5311O05200 20 x 2 x 0.5 16/0.2 CAT Black 527 22.1 75 39.7

5311O07010 1 x 2 x 0.75 24/0.2 CAT Black 73 7.0 115 26.5

5311O07020 2 x 2 x 0.75 24/0.2 CAT Black 105 8.0 115 26.5

5311O07050 5 x 2 x 0.75 24/0.2 CAT Black 255 14.0 75 26.5

5311O07100 10 x 2 x 0.75 24/0.2 CAT Black 430 18.4 75 26.5

5311O07200 20 x 2 x 0.75 24/0.2 CAT Black 740 24.2 75 26.5

5311O15010 1 x 2 x 1.5 7/0.53 CAT Black 84 7.8 120 12.3

5311O15020 2 x 2 x 1.5 7/0.53 CAT Black 129 9.1 120 12.3

5311O15050 5 x 2 x 1.5 7/0.53 CAT Black 310 15.5 85 12.3

5311O15100 10 x 2 x 1.5 7/0.53 CAT Black 570 20.3 85 12.3

5311O15200 20 x 2 x 1.5 7/0.53 CAT Black 1043 26.9 85 12.3

Part 1, Type 1 - PE Insulation, Unarmoured, Individual & Collective Aluminium Tape Screen, PVC Sheath

5311I05020 2 x 2 x 0.5 16/0.2 ICAT Black 130 11.7 115 39.7

5311I05050 5 x 2 x 0.5 16/0.2 ICAT Black 217 14.3 115 39.7

5311I05100 10 x 2 x 0.5 16/0.2 ICAT Black 403 19.6 115 39.7

5311I05200 20 x 2 x 0.5 16/0.2 ICAT Black 667 25.4 115 39.7

5311I07020 2 x 2 x 0.75 24/0.2 ICAT Black 190 12.5 115 26.5

5311I07050 5 x 2 x 0.75 24/0.2 ICAT Black 300 16.0 115 26.5

5311I07100 10 x 2 x 0.75 24/0.2 ICAT Black 530 22.3 115 26.5

5311I07200 20 x 2 x 0.75 24/0.2 ICAT Black 667 29.2 115 26.5

5311I15020 2 x 2 x 1.5 7/0.53 ICAT Black 230 14.4 120 12.3

5311I15050 5 x 2 x 1.5 7/0.53 ICAT Black 410 18.5 120 12.3

5311I15100 10 x 2 x 1.5 7/0.53 ICAT Black 730 26.1 120 12.3

5311I15200 20 x 2 x 1.5 7/0.53 ICAT Black 1283 34.2 120 12.3

Capacitance figures are mutual @1kHz. ** For a Blue sheath, change the last character of the part number (0) to 1.

Larger pair counts and triple configurations are available on request.

CPR-Compliant Options Available

* Outer diameter are for reference only and can vary between manufacturers, please check at time of order.

www.fscables.com | sales@fscables.com


BS 5308

115

(BS 5308 Part 1 Type 1) Unarmoured LSHF Instrumentation Cable

Low Smoke Halogen Free (LSHF) versions of BS 5308 have been widely adopted in commercial building management

and industrial applications where fire safety is paramount. Available with collective aluminium tape (CAT) screening or

individual and collective aluminium tape (ICAT) screens to prevent electrical interference.

CONSTRUCTION

Type: CAT – Collective Aluminium Tape Screen

Plain annealed copper wire conductors to BS EN 60228, class 2

or 5, PE insulation, cores twisted into pairs, overall aluminium/

polyester foil screen and 0.5mm² tinned copper drain wire, LSHF

sheath – black or blue.**

Type: ICAT – Individual & Collective Aluminium Tape Screen

Plain annealed copper wire conductors to BS EN 60228, class 2

or 5, PE insulation, cores twisted into pairs, each pair aluminium/

polyester foil screen and 0.5mm² tinned copper drain wire, units

laid up, collective aluminium/ polyester foil screen and 0.5mm²

tinned copper drain wire, LSHF sheath – black or blue.**

Pair Identification:

CAT: Cables up to 50 pair are colour coded in accordance with BS

5308 pt 1, appendix A, see page 213. Two pair cables are twisted

as a quad and coloured black, blue, green, brown.

ICAT: Each pair black, blue and numbered cores or tapes.

TECHNICAL INFORMATION

Voltage Rating: 300/500V

Temperature Rating:

Conductor Stranding:

L/R Ratio:

+65°C (minimum 0°C for installation)

BS EN 60228 Class 2 or 5 plain

copper conductors

0.5mm² & 0.75mm² = 25 µH/Ohm

1.5mm² = 40 µH/Ohm

Flame Retardant: IEC/BS EN 60332-1-2

Smoke Emission: IEC/BS EN 61034-2

Halogen Emission: IEC/BS EN 60754-1 & 2

Manufactured

Generally To: PAS 5308 Part 1

Increased flame retardant versions to IEC/BS EN 60332-3-24 Cat

C and fire resistant versions to IEC/BS EN 60331-21 are available

on request. 0.6/1kV versions can be manufactured to order.

Part No. Pairs x mm 2 Stranding

Condusctor

mm

Screen

Type

Colour

Weight

kg/km

O/D

mm*

Cap.

pF/m

Conductor

Resistance

Ohms/Km

Part 1, Type 1 - PE Insulation, Unarmoured, Collective Aluminium Tape Screen, LSHF Sheath

5311O05010H 1 x 2 x 0.5 16/0.2 CAT Black 54 6.8 115 39.7

5311O05020H 2 x 2 x 0.5 16/0.2 CAT Black 75 7.7 115 39.7

5311O05050H 5 x 2 x 0.5 16/0.2 CAT Black 187 12.9 75 39.7

5311O05100H 10 x 2 x 0.5 16/0.2 CAT Black 310 17.0 75 39.7

5311O05200H 20 x 2 x 0.5 16/0.2 CAT Black 527 22.1 75 39.7

5311O07010H 1 x 2 x 0.75 24/0.2 CAT Black 73 7.0 115 26.5

5311O07020H 2 x 2 x 0.75 24/0.2 CAT Black 105 8.0 115 26.5

5311O07050H 5 x 2 x 0.75 24/0.2 CAT Black 255 14.0 75 26.5

5311O07100H 10 x 2 x 0.75 24/0.2 CAT Black 430 18.4 75 26.5

5311O07200H 20 x 2 x 0.75 24/0.2 CAT Black 740 24.2 75 26.5

5311O15010H 1 x 2 x 1.5 7/0.53 CAT Black 84 7.8 120 12.3

5311O15020H 2 x 2 x 1.5 7/0.53 CAT Black 129 9.1 120 12.3

5311O15050H 5 x 2 x 1.5 7/0.53 CAT Black 310 15.5 85 12.3

5311O15100H 10 x 2 x 1.5 7/0.53 CAT Black 570 20.3 85 12.3

5311O15200H 20 x 2 x 1.5 7/0.53 CAT Black 1043 26.9 85 12.3

Part 1, Type 1 - PE Insulation, Unarmoured, Individual & Collective Aluminium Tape Screen, LSHF Sheath

5311I05020H 2 x 2 x 0.5 16/0.2 ICAT Black 130 11.7 115 39.7

5311I05050H 5 x 2 x 0.5 16/0.2 ICAT Black 217 14.3 115 39.7

5311I05100H 10 x 2 x 0.5 16/0.2 ICAT Black 403 19.6 115 39.7

5311I05200H 20 x 2 x 0.5 16/0.2 ICAT Black 667 25.4 115 39.7

5311I07020H 2 x 2 x 0.75 24/0.2 ICAT Black 190 12.5 115 26.5

5311I07050H 5 x 2 x 0.75 24/0.2 ICAT Black 300 16.0 115 26.5

5311I07100H 10 x 2 x 0.75 24/0.2 ICAT Black 530 22.3 115 26.5

5311I07200H 20 x 2 x 0.75 24/0.2 ICAT Black 667 29.2 115 26.5

5311I15020H 2 x 2 x 1.5 7/0.53 ICAT Black 230 14.4 120 12.3

5311I15050H 5 x 2 x 1.5 7/0.53 ICAT Black 410 18.5 120 12.3

5311I15100H 10 x 2 x 1.5 7/0.53 ICAT Black 730 26.1 120 12.3

5311I15200H 20 x 2 x 1.5 7/0.53 ICAT Black 1283 34.2 120 12.3

5311O15050H

Capacitance figures are mutual @1kHz. ** For a Blue sheath, change the last character of the part number (0) to 1.

Larger pair counts and triple configurations are available on request.

* Outer diameter are for reference only and can vary between manufacturers, please check at time of order.

Low Smoke Halogen Free

CPR-Compliant Options Available

Tel: 01727 840 841

SIGNAL & CONTROL


116

BS 5308

(BS 5308 Part 1 Type 2) Armoured PVC Instrumentation Cable

BS 5308 part 1 type 2 cables incorporate a Steel Wire Armour (SWA) for use in aggressive process control and

instrumentation applications where mechanical damage is possible. Like the unarmoured versions, they are available with

collective aluminium tape (CAT) screening or individual and collective aluminium tape (ICAT) screens.

CONSTRUCTION

Type: CAT – Collective Aluminium Tape Screen

Plain annealed copper wire conductors to BS EN 60228, class 2

or 5, PE insulation, cores twisted into pairs, overall aluminium/

polyester foil screen and 0.5mm² tinned copper drain wire, PE

bedding GSWA armour, PVC sheath – black or blue.**

Type: ICAT – Individual & Collective Aluminium Tape Screen

Plain annealed copper wire conductors to BS EN 60228, class 2

or 5, PE insulation, cores twisted into pairs, each pair aluminium/

polyester foil screen and 0.5mm² tinned copper drain wire, units

laid up, collective aluminium/polyester foil screen and 0.5mm²

tinned copper drain wire, PE bedding, GSWA armour, PVC sheath

– black or blue.**

Pair Identification:

CAT: Cables up to 50 pair are colour coded in accordance with BS

5308 pt 1, appendix A, see page 213. Two pair cables are twisted

as a quad and coloured black, blue, green, brown.

ICAT: Each pair black, blue and numbered cores or tapes.

TECHNICAL INFORMATION

Voltage Rating: 300/500V

Temperature Rating:

Conductor Stranding:

L/R Ratio:

+65°C (minimum 0°C for installation)

BS EN 60228 Class 2 or 5 plain

copper conductors

0.5mm² & 0.75mm² = 25 µH/Ohm

1.5mm² = 40 µH/Ohm

Flame Retardant: IEC/BS EN 60332-1-2

Manufactured

Generally To: PAS 5308 Part 1

0.6/1kV versions can be manufactured to order.

5312I15050 Part No. Pairs x mm 2 Condusctor

Stranding

Screen

Type

Colour

Weight

kg/km

O/D

mm*

Cap.

pF/m

Conductor

Resistance

Ohms/Km

Part 1, Type 2 - PE Insulation, Collective Aluminium Tape Screen, PE, GSWA, PVC Sheath

5312O05010 1 x 2 x 0.5 16/0.2 CAT Black 237 11.2 115 39.7

5312O05020 2 x 2 x 0.5 16/0.2 CAT Black 287 12.1 115 39.7

5312O05050 5 x 2 x 0.5 16/0.2 CAT Black 530 17.7 75 39.7

5312O05100 10 x 2 x 0.5 16/0.2 CAT Black 917 22.7 75 39.7

5312O05200 20 x 2 x 0.5 16/0.2 CAT Black 1550 28.9 75 39.7

5312O07010 1 x 2 x 0.75 24/0.2 CAT Black 260 11.4 115 26.5

5312O07020 2 x 2 x 0.75 24/0.2 CAT Black 310 12.6 115 26.5

5312O07050 5 x 2 x 0.75 24/0.2 CAT Black 675 19.0 75 26.5

5312O07100 10 x 2 x 0.75 24/0.2 CAT Black 1170 25.0 75 26.5

5312O07200 20 x 2 x 0.75 24/0.2 CAT Black 1725 31.0 75 26.5

5312O15010 1 x 2 x 1.5 7/0.53 CAT Black 320 12.7 120 12.3

5312O15020 2 x 2 x 1.5 7/0.53 CAT Black 413 14.1 120 12.3

5312O15050 5 x 2 x 1.5 7/0.53 CAT Black 910 21.9 85 12.3

5312O15100 10 x 2 x 1.5 7/0.53 CAT Black 1383 28.2 85 12.3

5312O15200 20 x 2 x 1.5 7/0.53 CAT Black 2400 35.8 85 12.3

Part 1, Type 2 - PE Insulation, Individual & Collective Aluminium Tape Screen, PE, GSWA, PVC Sheath

5312I05020 2 x 2 x 0.5 16/0.2 ICAT Black 457 16.8 115 39.7

5312I05050 5 x 2 x 0.5 16/0.2 ICAT Black 757 20.9 115 39.7

5312I05100 10 x 2 x 0.5 16/0.2 ICAT Black 1293 27.9 115 39.7

5312I05200 20 x 2 x 0.5 16/0.2 ICAT Black 2237 34.3 115 39.7

5312I07020 2 x 2 x 0.75 24/0.2 ICAT Black 500 17.6 115 26.5

5312I07050 5 x 2 x 0.75 24/0.2 ICAT Black 935 22.0 115 26.5

5312I07100 10 x 2 x 0.75 24/0.2 ICAT Black 1630 29.5 115 26.5

5312I07200 20 x 2 x 0.75 24/0.2 ICAT Black 2410 37.8 115 26.5

5312I15020 2 x 2 x 1.5 7/0.53 ICAT Black 737 20.4 120 12.3

5312I15050 5 x 2 x 1.5 7/0.53 ICAT Black 1187 25.4 120 12.3

5312I15100 10 x 2 x 1.5 7/0.53 ICAT Black 1847 33.5 120 12.3

5312I15200 20 x 2 x 1.5 7/0.53 ICAT Black 3053 42.6 120 12.3

Capacitance figures are mutual @1kHz. ** For a Blue sheath, change the last character of the part number (0) to 1.

Larger pair counts and triple configurations are available on request.

CPR-Compliant Options Available

* Outer diameter are for reference only and can vary between manufacturers, please check at time of order.

www.fscables.com | sales@fscables.com


BS 5308

117

(BS 5308 Part 1 Type 2) Armoured LSHF Instrumentation Cable

These armoured cables are ideal for use in industrial and commercial applications where smoke/toxic gas release is a

problem in the event of a fire and mechanical damage is a threat. Although they were originally conceived for industrial

instrumentation applications BS 5308 cables are now used within a wide variety of industries including commercial

building management control.

BS 5308 cables are available with collective aluminium tape (CAT) screening or individual and collective aluminium tape

(ICAT) screens to ensure correct signal transmission in noisy electrical environments.

CONSTRUCTION

Type: CAT – Collective Aluminium Tape Screen

Plain annealed copper wire conductors to BS EN 60228, class 2 or

5, PE insulation, cores twisted into pairs, overall aluminium/polyester

foil screen and 0.5mm² tinned copper drain wire, PE bedding GSWA

armour, Low Smoke Halogen Free (LSHF) sheath – black or blue.**

Type: ICAT – Individual & Collective Aluminium Tape Screen

Plain annealed copper wire conductors to BS EN 60228, class 2

or 5, PE insulation, cores twisted into pairs, each pair aluminium/

polyester foil screen and 0.5mm² tinned copper drain wire, units

laid up, collective aluminium/polyester foil screen and 0.5mm²

tinned copper drain wire, PE bedding, GSWA armour, LSHF sheath

– black or blue.**

Pair Identification:

CAT: Cables up to 50 pair are colour coded in accordance with BS

5308 pt 1, appendix A, see page 213. Two pair cables are twisted

as a quad and coloured black, blue, green, brown.

ICAT: Each pair black, blue and numbered cores or tapes.

TECHNICAL INFORMATION

Voltage Rating: 300/500V

Temperature Rating:

Conductor Stranding:

L/R Ratio:

+65°C (minimum 0°C for installation)

BS EN 60228 Class 2 or 5 plain

copper conductors

0.5mm² & 0.75mm² = 25 µH/Ohm

1.5mm² = 40 µH/Ohm

Flame Retardant: IEC/BS EN 60332-1-2

Smoke Emission: IEC/BS EN 61034-2

Halogen Emission: IEC/BS EN 60754-1 & 2

Manufactured

Generally To: PAS 5308 Part 1

Increased flame retardant versions to IEC/BS EN 60332-3-24 Cat

C and fire resistant versions to IEC/BS EN 60331-21 are available

on request. 0.6/1kV versions can be manufactured to order.

Part No. Pairs x mm 2 Condusctor

Stranding

Screen

Type

Colour

Weight

kg/km

O/D

mm*

Cap.

pF/m

Conductor

Resistance

Ohms/Km

Part 1, Type 2 - PE Insulation, Collective Aluminium Tape Screen, PE, GSWA, LSHF sheath

5312O05010H 1 x 2 x 0.5 16/0.2 CAT Black 237 11.2 115 39.7

5312O05020H 2 x 2 x 0.5 16/0.2 CAT Black 287 12.1 115 39.7

5312O05050H 5 x 2 x 0.5 16/0.2 CAT Black 530 17.7 75 39.7

5312O05100H 10 x 2 x 0.5 16/0.2 CAT Black 917 22.7 75 39.7

5312O05200H 20 x 2 x 0.5 16/0.2 CAT Black 1550 28.9 75 39.7

5312O07010H 1 x 2 x 0.75 24/0.2 CAT Black 260 11.4 115 26.5

5312O07020H 2 x 2 x 0.75 24/0.2 CAT Black 310 12.6 115 26.5

5312O07050H 5 x 2 x 0.75 24/0.2 CAT Black 675 19.0 75 26.5

5312O07100H 10 x 2 x 0.75 24/0.2 CAT Black 1170 25.0 75 26.5

5312O07200H 20 x 2 x 0.75 24/0.2 CAT Black 1725 31.0 75 26.5

5312O15010H 1 x 2 x 1.5 7/0.53 CAT Black 320 12.7 120 12.3

5312O15020H 2 x 2 x 1.5 7/0.53 CAT Black 413 14.1 120 12.3

5312O15050H 5 x 2 x 1.5 7/0.53 CAT Black 910 21.9 85 12.3

5312O15100H 10 x 2 x 1.5 7/0.53 CAT Black 1383 28.2 85 12.3

5312O15200H 20 x 2 x 1.5 7/0.53 CAT Black 2400 35.8 85 12.3

Part 1, Type 2 - PE Insulation, Individual & Collective Aluminium Tape Screen, PE, GSWA, LSHF Sheath

5312I05020H 2 x 2 x 0.5 16/0.2 ICAT Black 457 16.8 115 39.7

5312I05050H 5 x 2 x 0.5 16/0.2 ICAT Black 757 20.9 115 39.7

5312I05100H 10 x 2 x 0.5 16/0.2 ICAT Black 1293 27.9 115 39.7

5312I05200H 20 x 2 x 0.5 16/0.2 ICAT Black 2237 34.3 115 39.7

5312I07020H 2 x 2 x 0.75 24/0.2 ICAT Black 500 17.6 115 26.5

5312I07050H 5 x 2 x 0.75 24/0.2 ICAT Black 935 22.0 115 26.5

5312I07100H 10 x 2 x 0.75 24/0.2 ICAT Black 1630 29.5 115 26.5

5312I07200H 20 x 2 x 0.75 24/0.2 ICAT Black 2410 37.8 115 26.5

5312I15020H 2 x 2 x 1.5 7/0.53 ICAT Black 737 20.4 120 12.3

5312I15050H 5 x 2 x 1.5 7/0.53 ICAT Black 1187 25.4 120 12.3

5312I15100H 10 x 2 x 1.5 7/0.53 ICAT Black 1847 33.5 120 12.3

5312I15200H 20 x 2 x 1.5 7/0.53 ICAT Black 3053 42.6 120 12.3

Capacitance figures are mutual @1kHz. ** For a Blue sheath, change the last character of the part number (0) to 1.

Larger pair counts and triple configurations are available on request.

* Outer diameter are for reference only and can vary between manufacturers, please check at time of order.

Low Smoke Halogen Free

CPR-Compliant Options Available

5312O07050H

Tel: 01727 840 841

SIGNAL & CONTROL


118

Spiral Cables

Spiral Cables

FSC offers both signal and power versions of retractable spiral cables. The variations in conductor size, insulation and

sheath materials are enormous. Having decided on the conductor size and the number of cores it is important to choose

the insulation and sheath materials most suitable for the task. The retracted length of the spiral can be made to your

requirements up to 5m.

Although once popular, PVC is now giving way to polyurethane as a sheathing material which has a much better

memory. Rubber is still popular with hytrel, used for the highest performance cables. The sizes and types shown on the

page opposite are a small selection of the spiral cables offered. There are many other sheathing, insulation materials and

voltage ratings as well as screened versions available. Please call with your exact requirement.

These cables are manufactured to order, to meet your needs precisely. You can specify tail lengths (the straights bits at

either end). The standard length is at least 150mm and they can be supplied in line (straight) or at right angles to the coil.

Delivery is normally around 14 working days but please check when ordering. Many other core combinations are

available. Please call to discuss your requirements.

SPIRAL

CONSTRUCTION - PVC SPIRAL CABLE

Fine copper wire strands. PVC insulation,

colour coded cores, twisted together, PVC

jacket.

TECHNICAL INFORMATION

Voltage Rating: Working 300/500V

Temperature Rating:

-5°C to +70°C

Approximate Extension Ratio: 3.5:1

PVC Spirals

Part No. Cores x mm 2

88200702 2 x 0.75

88200703 3 x 0.75

88200704 4 x 0.75

88200705 5 x 0.75

88201002 2 x 1.0

88201003 3 x 1.0

Part No. Cores x mm 2

88201004 4 x 1.0

88201005 5 x 1.0

88201502 2 x 1.5

88201503 3 x 1.5

88201504 4 x 1.5

Part No. Cores x mm 2

88201505 5 x 1.5

88202502 2 x 2.5

88202503 3 x 2.5

88202504 4 x 2.5

88202505 5 x 2.5

CONSTRUCTION: PUR SCREENED

SPIRAL CABLE

Fine copper wire strands of class 5 or 6.

TPE insulation, colour coded cores, twisted

together, overall tinned copper wire braid,

PUR jacket.

TECHNICAL INFORMATION

Voltage Rating:

Temperature Rating:

Approximate Extension Ratio: 4:1

Working ≤0.25mm² 100V

≥ 0.5mm² 300V

25°C to +80°C

PUR Screened Spirals

Part No. Cores x mm 2

88300102 2 x 0.14

88300103 3 x 0.14

88300104 4 x 0.14

88300105 5 x 0.14

88300106 6 x 0.14

88300107 7 x 0.14

88300108 8 x 0.14

88300112 12 x 0.14

88300118 18 x 0.14

88300125 25 x 0.14

Part No. Cores x mm 2

88300202 2 x 0.25

88300203 3 x 0.25

88300204 4 x 0.25

88300205 5 x 0.25

88300206 6 x 0.25

88300207 7 x 0.25

88300208 8 x 0.25

88300212 12 x 0.25

88300218 18 x 0.25

88300225 25 x 0.25

Part No. Cores x mm 2

88300503 3 x 0.5

88300504 4 x 0.5

88300505 5 x 0.5

88300506 6 x 0.5

88300507 7 x 0.5

88300508 8 x 0.5

88300512 12 x 0.5

88300518 18 x 0.5

88300525 25 x 0.5

Please note at high or low ambient temperatures all spiral cables will loose some of their memory

www.fscables.com | sales@fscables.com


Spiral Cables

119

CONSTRUCTION: PUR SPIRAL CABLE

Fine copper wire strands of class 5 or 6. TPE or EPR insulation,

colour coded cores, twisted together, PUR jacket.

TECHNICAL INFORMATION

Voltage Rating: Working 300/500V

Temperature Rating:

-25°C to +85°C

Approximate Extension Ratio: 4:1

PUR Unscreened Spirals

Part No. Cores x mm 2

Part No. Cores x mm 2

Part No. Cores x mm 2

Part No. Cores x mm 2

88100102 2 x 0.14

88100103 3 x 0.14

88100104 4 x 0.14

88100105 5 x 0.14

88100106 6 x 0.14

88100107 7 x 0.14

88100108 8 x 0.14

88100110 10 x 0.14

88100112 12 x 0.14

88100116 16 x 0.14

88100125 25 x 0.14

88100202 2 x 0.25

88100203 3 x 0.25

88100204 4 x 0.25

88100205 5 x 0.25

88100206 6 x 0.25

88100207 7 x 0.25

88100208 8 x 0.25

88100210 10 x 0.25

88100212 12 x 0.25

88100216 16 x 0.25

88100225 25 x 0.25

88100502 2 x 0.5

88100503 3 x 0.5

88100504 4 x 0.5

88100505 5 x 0.5

88100506 6 x 0.5

88100507 7 x 0.5

88100508 8 x 0.5

88100510 10 x 0.5

88100512 12 x 0.5

88100516 16 x 0.5

88100525 25 x 0.5

88100702 2 x 0.75

88100703 3 x 0.75

88100704 4 x 0.75

88100705 5 x 0.75

88101002 2 x 1.0

88101003 3 x 1.0

88101004 4 x 1.0

88101005 5 x 1.0

88101007 7 x 1.0

88101012 12 x 1.0

88101502 2 x 1.5

88101503 3 x 1.5

88101504 4 x 1.5

88101505 5 x 1.5

88101507 7 x 1.5

88101512 12 x 1.5

88102503 3 x 2.5

88102504 4 x 2.5

88102505 5 x 2.5

88104004 4 x 4.0

88104005 5 x 4.0

88106004 4 x 6.0

CONSTRUCTION: RUBBER TPE SPIRAL CABLE

Fine copper wire strands of class 5. Special PVC insulation, colour

coded cores, twisted together, black TPE synthetic rubber jacket.

TECHNICAL INFORMATION

Voltage Rating: Working 300/500V

Temperature Rating:

-15°C to +80°C

Approximate Extension Ratio: 5:1

Rubber TPE Spirals

Part No. Cores x mm 2

88000702 2 x 0.75

88000703 3 x 0.75

88000704 4 x 0.75

88000705 5 x 0.75

88000707 7 x 0.75

88000710 10 x 0.75

88000715 15 x 0.75

88001002 2 x 1.0

88001003 3 x 1.0

88001004 4 x 1.0

88001005 5 x 1.0

Part No. Cores x mm 2

88001007 7 x 1.0

88001010 10 x 1.0

88001015 15 x 1.0

88001502 2 x 1.5

88001503 3 x 1.5

88001504 4 x 1.5

88001505 5 x 1.5

88001507 7 x 1.5

88001510 10 x 1.5

88001515 15 x 1.5

Part No. Cores x mm 2

88002502 2 x 2.5

88002503 3 x 2.5

88002504 4 x 2.5

88002505 5 x 2.5

88002507 7 x 2.5

88004003 3 x 4.0

88004004 4 x 4.0

88004005 5 x 4.0

88006003 3 x 6.0

88006004 4 x 6.0

ST

LC

LE

ST

ST

RA

Length of

straight tail (Axial)

Length of tail

at right angles (Tangent)

DS

LE Length extended

LC Length closed

RA

RA

DS Diameter of spiral

DC

DC Diameter of cable

Tel: 01727 840 841

SIGNAL & CONTROL


120

Hi-Flex HF-100 & HF-100-C PUR

Hi-Flex HF-100 & HF-100-C PUR

Abrasion on cables that are constantly flexing is becoming a much more widespread problem. To overcome this, FSC has

introduced the HF-100 range of polyurethane sheathed cables which will outlast conventional PVC sheathing.

The low friction polyurethane sheath resists wear caused by constant rubbing either in a cable chain or where free

movement brings the cable into contact with part of the machine. Suitable for use in cable chains as well as for free

movement the HF-100 range will provide a long term solution to many regular flexing applications.

Both the screened and unscreened versions use fleece tapes and talcum to enable the core bundle and, where

appropriate, the screening braid to move as the cable flexes. This reduces the stress imposed on the conductors and braid.

22501007

CONSTRUCTION - HF-100

Very fine copper wire strands to BS EN 60228

Class 6. Black polyolefin insulation with white

numbers. A green/yellow earth core is included in

cables with more than 2 cores. Cores twisted in

layers & fleece taped. Grey polyurethane sheath

to RAL 7001

CONSTRUCTION - HF-100-C SCREENED

Very fine copper wire strands to BS EN 60228

Class 6. Black polyolefin insulation with white

numbers. A green/yellow earth core is included

in cables with more than 2 cores. Cores twisted

in layers & textile taped. Grey PVC inner sheath.

Fleece tape. Tinned copper wire braid. Fleece

wrap. Grey polyurethane outer sheath

to RAL 7001.

HF-100 Unscreened

Part No. Cores x mm 2 O/D mm

20500502 2 x 0.5 5.5

20500503 3 x 0.5 5.8

20500504 4 x 0.5 6.2

20500505 5 x 0.5 6.7

20500507 7 x 0.5 7.7

20500512 12 x 0.5 9.7

20500518 18 x 0.5 10.8

20500520 20 x 0.5 11.4

20500525 25 x 0.5 12.7

20500527 27 x 0.5 13.5

20500530 30 x 0.5 13.9

20500536 36 x 0.5 14.5

20500702 2 x 0.75 6.1

20500703 3 x 0.75 6.4

20500704 4 x 0.75 6.8

20500705 5 x 0.75 7.4

20500707 7 x 0.75 8.8

20500712 12 x 0.75 10.3

20500718 18 x 0.75 11.9

20500720 20 x 0.75 12.6

20500725 25 x 0.75 14.1

20500734 34 x 0.75 15.3

TECHNICAL INFORMATION

Voltage Rating: Working 300/500V

Test

3000V

Temperature Rating:

Bending Radius:

Conductor Stranding:

Flexing -30°C to+80°C

Flexing 5 x cable diameter

To BS EN 60228 Class 6 & VDE

0295 Table 4

Also available in 0.14mm 2 , 0.25mm 2 and 0.34mm 2

screened or unscreened with DIN 47100 colour codes.

Please see page 212.

Part No. Cores x mm 2 O/D mm

20500730 30 x 0.75 15.0

20500736 36 x 0.75 15.9

20501002 2 x 1.0 6.7

20501003 3 x 1.0 7.1

20501004 4 x 1.0 7.5

20501005 5 x 1.0 8.6

20501007 7 x 1.0 9.3

20501012 12 x 1.0 11.1

20501018 18 x 1.0 12.9

20501020 20 x 1.0 13.6

20501025 25 x 1.0 15.4

20501027 27 x 1.0 16.2

20501030 30 x 1.0 16.5

20501036 36 x 1.0 18.2

20501502 2 x 1.5 7.4

20501503 3 x 1.5 7.7

20501504 4 x 1.5 8.3

20501505 5 x 1.5 9.0

20501507 7 x 1.5 10.3

20501512 12 x 1.5 12.6

20501518 18 x 1.5 14.6

20501520 20 x 1.5 15.3

www.fscables.com | sales@fscables.com


Hi-Flex HF-100 & HF-100-C PUR

121

Part No. Cores x mm 2 O/D mm

20501525 25 x 1.5 17.6

20501527 27 x 1.5 17.9

20501530 30 x 1.5 18.4

20501536 36 x 1.5 19.7

20502503 3 x 2.5 8.9

20502504 4 x 2.5 9.7

20502505 5 x 2.5 10.5

20502507 7 x 2.5 12.0

20502512 12 x 2.5 14.3

20502518 18 x 2.5 17.1

20502525 25 x 2.5 21.0

Part No. Cores x mm 2 O/D mm

20504004 4 x 4.0 12.1

20504005 5 x 4.0 13.2

20506004 4 x 6.0 13.1

20506005 5 x 6.0 14.9

20510004 4 x 10 16.6

20516004 4 x 16 19.5

HF-100-C Screened

Part No. Cores x mm 2 O/D mm

22500502 2 x 0.5 8.2

22500503 3 x 0.5 8.6

22500504 4 x 0.5 8.9

22500505 5 x 0.5 9.2

22500507 7 x 0.5 909

22500512 12 x 0.5 11.1

22500518 18 x 0.5 12.7

22500520 20 x 0.5 13.9

22500525 25 x 0.5 15.5

22500530 30 x 0.5 15.8

22500536 36 x 0.5 17.0

22500702 2 x 0.75 8.1

22500703 3 x 0.75 8.6

22500704 4 x 0.75 9.1

22500705 5 x 0.75 9.9

22500707 7 x 0.75 10.5

22500712 12 x 0.75 12.4

22500718 18 x 0.75 14.2

22500720 20 x 0.75 15.1

22500725 25 x 0.75 16.8

22500730 30 x 0.75 18.1

22500736 36 x 0.75 18.9

22501002 2 x 1.0 8.9

22501003 3 x 1.0 9.2

22501004 4 x 1.0 9.7

22501005 5 x 1.0 10.5

22501007 7 x 1.0 11.4

22501012 12 x 1.0 13.7

22501018 18 x 1.0 15.5

Part No. Cores x mm 2 O/D mm

22501020 20 x 1.0 16.4

22501025 25 x 1.0 18.3

22501030 30 x 1.0 19.3

22501036 36 x 1.0 20.8

22501502 2 x 1.5 9.2

22501503 3 x 1.5 9.8

22501504 4 x 1.5 10.5

22501505 5 x 1.5 11.1

22501507 7 x 1.5 12.4

22501512 12 x 1.5 15.0

22501518 18 x 1.5 17.2

22501520 20 x 1.5 18.5

22501525 25 x 1.5 20.9

22501530 30 x 1.5 21.5

22501536 36 x 1.5 23.7

22502503 3 x 2.5 11.1

22502504 4 x 2.5 11.7

22502505 5 x 2.5 12.8

22502507 7 x 2.5 14.5

22502512 12 x 2.5 17.2

22502518 18 x 2.5 20.8

22504004 4 x 4.0 14.5

22504005 5 x 4.0 16.1

22506004 4 x 6.0 16.1

22506005 5 x 6.0 17.6

22510004 4 x 10 19.8

22510005 5 x 10 22.5

22516004 4 x 16 23.4

22516005 5 x 16 25.4

Tel: 01727 840 841

SIGNAL & CONTROL


122

HF-120 Unscreened & HF-120-C Screened

HF-120 Unscreened & HF-120-C Screened

Hi-Flex 120 & 120-C screened data cables are designed to last in even the most hostile chain or free movement

applications. The HF-120-C copper braid screened version protects the signal from EMI while the TPE insulation supports

the highly flexible conductors. Abrasion is reduced to a minimum by using a polyurethane low friction sheath. For

maximum life, Hi-Flex data cables should not be exposed to any torsional stresses or twisting. Many sizes are now

available with UL approval.

20500112

CONSTRUCTION - HF-120 & HF-120-C

Very fine copper wire strands. Polyolefin insulation

colour coded to DIN 47100. Cores twisted in

layers & fleece taped. (Screened versions have

a tinned copper wire braid & fleece wrap). Low

friction polyurethane outer sheath. Colour chart

page 212.

TECHNICAL INFORMATION

Voltage Rating: Working 250V

Temperature Rating: Flexing -30°C to +80°C

Bending Radius: Flexing 7.5 x cable diameter

22500207

HF-120 Unscreened

Part No.

Cores x

mm 2

Weight

kg/km

O/D

mm

20500102 2 x 0.14 14 3.7

20500103 3 x 0.14 17 4.2

20500104 4 x 0.14 20 4.4

20500105 5 x 0.14 24 4.6

20500107 7 x 0.14 29 5.1

20500110 10 x 0.14 37 5.9

20500112 12 x 0.14 43 6.2

20500114 14 x 0.14 49 6.4

20500118 18 x 0.14 58 6.9

20500125 25 x 0.14 81 7.6

20500202 2 x 0.25 18 4.3

20500203 3 x 0.25 21 4.5

20500204 4 x 0.25 25 4.8

20500205 5 x 0.25 29 5.2

20500207 7 x 0.25 41 5.9

20500210 10 x 0.25 58 6.9

20500212 12 x 0.25 61 7.2

20500214 14 x 0.25 68 7.4

20500218 18 x 0.25 85 8.0

20500225 25 x 0.25 101 9.3

20500302 2 x 0.34 20 4.3

20500303 3 x 0.34 25 4.7

20500304 4 x 0.34 30 5.0

20500305 5 x 0.34 36 5.5

20500307 7 x 0.34 45 6.0

20500310 10 x 0.34 69 6.9

20500312 12 x 0.34 71 7.1

20500314 14 x 0.34 81 7.4

20500318 18 x 0.34 97 8.5

20500325 25 x 0.34 136 9.9

HF-120-C Screened

Part No.

Cores x

mm 2

Weight

kg/km

O/D

mm

22500102 2 x 0.14 20 4.2

22500103 3 x 0.14 24 4.5

22500104 4 x 0.14 27 4.7

22500105 5 x 0.14 32 5.0

22500107 7 x 0.14 36 5.5

22500110 10 x 0.14 40 6.4

22500112 12 x 0.14 45 6.7

22500114 14 x 0.14 58 7.1

22500118 18 x 0.14 62 7.4

22500125 25 x 0.14 89 8.3

22500202 2 x 0.25 29 4.6

22500203 3 x 0.25 33 4.9

22500204 4 x 0.25 36 5.1

22500205 5 x 0.25 41 5.6

22500207 7 x 0.25 52 6.0

22500210 10 x 0.25 68 7.1

22500212 12 x 0.25 74 7.5

22500214 14 x 0.25 81 7.9

22500218 18 x 0.25 100 8.5

22500225 25 x 0.25 134 9.5

22500302 2 x 0.34 31 4.9

22500303 3 x 0.34 38 5.2

22500304 4 x 0.34 43 5.6

22500305 5 x 0.34 49 5.8

22500307 7 x 0.34 60 6.6

22500310 10 x 0.34 74 7.8

22500312 12 x 0.34 81 8.1

22500314 14 x 0.34 90 8.4

22500318 18 x 0.34 125 9.0

22500325 25 x 0.34 166 10.3

www.fscables.com | sales@fscables.com


HF-120-C-TP Paired Screened

123

HF-120-C-TP Paired Screened

The Hi-Flex twisted pair data cable is ideally suited to mechanically challenging data transmission applications. The tough

polyurethane jacket is cut and abrasion resistant, while being unaffected by solvents and oils. The tinned copper braid

screen copes well with frequent flexing and at the same time maintains signal integrity by minimising the effects of

electromagnetic interference. Many sizes are now available with UL approval. Not suitable for torsional stress or twisting

applications.

CONSTRUCTION - HF-120-C SCREENED

Very fine copper wire strands. Polyolefin insulation

colour coded to DIN 47100. Cores twisted in pairs

and laid up with fleece wrap, tinned copper wire

braid. Fleece wrap. Low friction polyurethane

outer sheath. Colour chart page 212.

TECHNICAL INFORMATION

Voltage Rating: Working 250V

Temperature Rating: Flexing -30°C to +80°C

Bending Radius: Flexing 10 x cable diameter

22600504

Part No.

Pairs x

mm 2

Weight

kg/km

O/D

mm

22600201 1 x 2 x 0.25 38 4.7

22600202 2 x 2 x 0.25 44 5.6

22600203 3 x 2 x 0.25 46 6.5

22600204 4 x 2 x 0.25 59 7.0

22600205 5 x 2 x 0.25 70 7.5

22600206 6 x 2 x 0.25 79 8.2

22600208 8 x 2 x 0.25 117 8.9

22600210 10 x 2 x 0.25 126 10.4

22600214 14 x 2 x 0.25 163 11.2

22600501 1 x 2 x 0.5 51 5.9

22600502 2 x 2 x 0.5 79 8.0

22600503 3 x 2 x 0.5 90 8.9

22600504 4 x 2 x 0.5 118 10.1

22600505 5 x 2 x 0.5 135 10.9

22600506 6 x 2 x 0.5 162 11.3

22600508 8 x 2 x 0.5 240 13.7

22600510 10 x 2 x 0.5 255 14.7

22600514 14 x 2 x 0.5 328 15.9

Part No.

Pairs x

mm 2

Weight

kg/km

O/D

mm

22600701 1 x 2 x 0.75 108 6.4

22600702 2 x 2 x 0.75 115 8.6

22600703 3 x 2 x 0.75 123 10.0

22600704 4 x 2 x 0.75 148 10.5

22600705 5 x 2 x 0.75 180 12.0

22600706 6 x 2 x 0.75 209 13.1

22600708 8 x 2 x 0.75 305 15.2

22600710 10 x 2 x 0.75 327 16.3

22600714 14 x 2 x 0.75 420 18.5

22601001 1 x 2 x 1.0 108 6.7

22601002 2 x 2 x 1.0 128 9.1

22601003 3 x 2 x 1.0 140 10.4

22601004 4 x 2 x 1.0 171 11.3

22601005 5 x 2 x 1.0 206 12.5

Tel: 01727 840 841

SIGNAL & CONTROL


124

HF-265 PUR Encoder

HF-265 PUR Encoder

Used for precise data transmission, these cables meet the specific requirements of automation control gear manufacture.

Fine copper wire strands with high-performance insulation and sheathing materials make them ideal for regular flexing

applications including use in cable chains where cut and abrasion resistance is vital.

Manufactured to DESINA ® with UL and CSA approval these cables also conform to EU low voltage directive

73/23/EEC , ensuring they are widely accepted around the world.

A wide variety of core combinations are manufactured as standard but please call us to discuss your specific needs. We

are constantly increasing the standard range and will produce special designs for low minimum order quantities.

26500241

CONSTRUCTION - HF-265 PUR ENCODER

Very fine copper wire strands to BS EN 60228

Class 6. Polypropylene insulation, colour coded.

Cores twisted in layers, including screened pairs

& fleece taped. Tinned copper wire braid. Fleece

wrap. Low friction green polyurethane outer

sheath. Please note individual types may

vary in construction from the above.

TECHNICAL INFORMATION

Voltage Rating: Working 300V

Test

2000V

Temperature Rating:

Bending Radius:

Flexing -30°C to +80°C

Flexing 10 x cable diameter

Part No. Cores x mm 2 Weight

kg/km

O/D

mm

System

265001125 10 x 0.14 + 2 x 0.5 70 8.1 Heidenhain

265001145 10 x 0.14 + 4 x 0.5 86 8.5 Heidenhain

265001545 15 x 0.14 + 4 x 0.5 127 8.9 Bosch

26500135 3 x (2 x 0.14) + 2 x (0.5) 101 9.6 Siemens GFX8008-1BD31

26500131 3 x (2 x 0.14) + 2 x (1.0) 109 8.5 Heidenhain

26500145 4 x 2 x 0.14 + 4 x 0.5 111 8.3 Heidenhain

26500275 4 x 2 x 0.25 + 2 x 0.5 123 8.9 Indramat INK0448

26500241 4 x 2 x 0.25 + 2 x 1.0 135 8.9 Indramat INK0209

26500345 4 x 2 x 0.38 + 4 x 0.5 199 8.7 Siemens GFX8008-1BD21

26500509 9 x 0.5 126 8.7 Indramat INK0208

26500132 3 x (2 x 0.14)+4 x 0.14 + 2 x 0.5 127 9.1 Siemens GFX8008-1BD41

26500134 3x(2x0.14)+4x0.14+4x0.23+2x0.5 149 10.2 Siemens GFX8008-1BD51

26500102 2 x 2 x 0.18 45 5.7 Siemens GFX8008-1BD71

26500104 4 x 2 x 0.18 57 6.6 Siemens GFX8008-1BD61

26500108 8 x 2 x 0.18 126 8.7 Siemens GFX8008-1BD11

26500224 4 x (2 x 0.14) 92 5.9 Heidenhain

26500144 4 x 2 x 0.14 + 4 x 0.25 97 6.3 Heidenhain

26500149 4 x 2 x 0.14 + 4 x 0.14 + 4 x 1.0 145 9.9 Indramat INK0532

26500222 2 x 2 x 0.25 + 2 x 0.5 90 7.8 Indramat INK0750

www.fscables.com | sales@fscables.com


HF-275 PUR Servo & Feedback Cables

125

HF-275 PUR Servo & Feedback Cables

Cables combining control, signal and power cores are now commonly used in industrial automation. Fine copper wire

strands with high-performance insulation and sheathing material make them ideal for regular flexing applications. A

wide variety of core combinations are manufactured as standard but please call us to discuss your specific needs. We are

constantly increasing the standard range and will produce special designs for low minimum order quantities.

CONSTRUCTION - HF-275 PUR SERVO

Power cores: very fine copper wire strands,

polyolefin insulation with cores 1-3 black with

white numbers, the fourth core is a green/yellow

earth.

Control or signal cores: very fine copper wire

strands, black TPE insulation with white numbers.

Aluminium/polyester foil with a tinned copper

braid screen, around each pair there is a polyester

foil wrap.

Power & signal cores are twisted together with

very short lay lengths. Synthetic fleece with overall

tinned copper wire braid, low friction polyurethane

sheath.

TECHNICAL INFORMATION

Voltage Rating:

Temperature Rating:

Bending Radius:

EC 0.6/1kV

Power cores Test V. 4000V

UL/CSA 1000V Control cores

Test V. 2000V

Flexing -30°C to +80°C

Flexing 7.5 x cable diameter

These cables have UL and CSA approval as well as meeting

the requirements of DESINA ® .

275025415

Part No. Cores x mm 2 Weight kg/km O/D mm

275007403 4G 0.75 + 2 x (2 x 0.34) 172 11.1

275010407 4G 1 + 2 x (2 x 0.75) 286 12.1

275015405 4G 1.5 + 2 x (2 x 0.5) 342 12.2

275015407 4G 1.5 + 2 x (2 x 0.75) 376 12.3

275025415 4G 2.5 + 2 x (2 x 1.5) 447 15.1

275040415 4G 4 + 2 x (2 x 1.5) 567 17.9

275060415 4G 6 + 2 x (2 x 1.5) 664 18.2

275100414 4G 10 + 2 x (2 x 1.5) 893 21.9

275160415 4G 16 + 2 x (2 x 1.5) 1298 26.9

275250415 4G 25 + 2 x (2 x 1.5) 1784 29.2

275350415 4G 35 + 2 x (2 x 1.5) 2588 32.7

275500425 4G 50 + 2 x (2 x 2.5) 3348 37.1

275015215 4G 1.5 + (2 x 1.5) 233 12.1

275025215 4G 2.5 + (2 x 1.5) 290 12.9

275040215 4G 4 + (2 x 1.5) 376 14.5

275060215 4G 6 + (2 x 1.5) 461 17.8

275100215 4G 10 + (2 x 1.5) 739 20.6

275160215 4G 16 + (2 x 1.5) 1123 23.6

275250215 4G 25 + (2 x 1.5) 1451 28.1

275350215 4G 35 + (2 x 1.5) 1919 32.1

275500215 4G 50 + (2 x 1.5) 2852 35.3

Tel: 01727 840 841

SIGNAL & CONTROL


126

Robotic Bus Cable

Robotic Bus Cable

To reflect the increasing need for higher data transmission rates that can be achieved with standard signal cables FSC

have brought together a selection of Bus and Industrial Ethernet Cables for frequent flexing. Normally available for quick

delivery and with no minimum order quantities they are the ideal choice for your flexible high-speed data application.

28100502

C5S26HF

Part No. Description No. of Pairs Size

2201PODFHF

Profibus DP PUR

High Flex UL

Weight

kg/km

O/D

mm

Sheath

Colour

1 0.64mm Ø 42 5.2 Violet

28100201 Can Bus PUR High Flex 1 0.22mm² 41 6.2 Violet

28100202 Can Bus PUR High Flex 2 0.22mm² 60 6.5 Violet

28100301 Can Bus PUR High Flex 1 0.34mm² 53 6.8 Violet

28100302 Can Bus PUR High Flex 2 0.34mm² 64 7.1 Violet

28100501 Can Bus PUR High Flex 1 0.50mm² 67 7.1 Violet

28100502 Can Bus PUR High Flex 2 0.50mm² 75 7.6 Violet

2403POBPHF Interbus PUR High Flex 3 0.22mm² 41 8.2 Violet

2403/3POBPHF

15ABDYHF

22ABDYHF

C52SHF

C5SHF

C5S26HF

2204CODPQHFPUR

Interbus PUR High Flex

DeviceNet Thick PUR

High Flex

DeviceNet Thin PUR

High Flex

Industrial Ethernet PUR

High Flex

Industrial Ethernet PUR

High Flex

Industrial Ethernet PUR

High Flex

Profinet Type C PUR

High Flex

3pair x 0.22

+ 3core x 1.0

1pair 15awg

+ 1pair 18awg

1pair 22awg

+ 1pair 24awg

61 9.3 Violet

209 12.1 Yellow

64 7.0 Yellow

2 24(19)awg 65 6.1 Green

4 24(19)awg 82 8.0 Green

4 26(19)awg 72 6.3 Green

2 22(7)awg 65 6.6 Green

www.fscables.com | sales@fscables.com


127

Coaxial

Introduction

Advances in the design and performance of coaxial

cables have been significant over the past few

years. As production techniques have evolved

producing triple layer dielectrics to increasingly

precise tolerances the performance has enabled

phenomenal data transmission rates to be achieved.

FSC cover all of the popular types from the

traditional RG military style to the widely used

commercial types such as WF100 Satellite and the

latest corrugated and braided varieties for mobile

and satellite communications.

You can be confident if you have a specific coaxial

need we can cross reference it and with massive

stocks, your cable may be with you on our standard

next working day delivery service.

Contents

RG 128 - 131

URM 132 & 133

WF Coaxial 134

TV Coaxial 135

Antennax Feeder 136

Antennax Connectors 137

Low Loss Coaxial 138

Composite Coaxial 139

To accompany the cable range we also stock a wide

range of connectors perfectly matched to suit the

cables.

Tel: 01727 840 841

COAXIAL


128

RG Coaxial

RG Coaxial

Originally developed for the American military the range of RG cables now has a wider use within the commercial

sectors. Most of the RG cables have been modified from the original military specification to increase their commercial

success. In some cases this is just a change to jacket or dielectric materials, in other cases its more fundamental,

changing braids and conductors. We are happy to provide full data sheets on the constructions of the cable we offer.

The most popular types are also kept in stock in both armoured and duct grade. For other types, armoured, coloured or

duct grade versions can be easily supplied often in quantities as low as 100m.

390059L

RG Coax Cable

Part No.

Description

Imp.

Ohms

Central

Cond.

Shield

Dielectric

Outer Weight

Sheath kg/km

390006C RG6 Type 75 1/1.02 AFS & AWB FPE PVC 47 6.8

390006CH RG6 Type LSHF 75 1/1.02 AFS & AWB FPE LSHF 47 6.8

390006Q RG6 Quad Shield 75 1/1.02 2 x AFS & AWB FPE PVC 49 7.6

390006QH RG6 Quad Shield LSHF 75 1/1.02 2 x AFS & AWB FPE PVC 49 7.6

390008C RG8 Type 50 1/2.74 AFS & TCWB PE PE 207 10.2

390008CH RG8 Type LSHF 50 1/2.74 AFS & TCWB PE LSHF 207 10.2

390011 RG11 A/U 75 7/0.40 PCWB PE PVC 149 10.3

390011H RG11 A/U LSHF 75 7/0.40 PCWB PE LSHF 149 10.3

390011A RG11 A/U SWA 75 7/0.40 PCWB PE PE 380 15.7

390058 RG58 C/U 50 19/0.18 TCWB PE PVC 46 5.1

390058H RG58 C/U LSHF 50 19/0.18 TCWB PE LSHF 46 5.1

390058D RG58 C/U Duct 50 19/0.18 TCWB PE PE 59 6.5

390059L RG59 B/U 75 1/0.58 PCWB PE LSF 60 6.1

390059H RG59 B/U LSHF 75 1/0.58 PCWB PE LSHF 60 6.1

390059D RG59 B/U Duct 75 1/0.58 PCWB PE PE 76 7.9

390059A RG59 B/U SWA 75 1/0.58 PCWB PE PE 250 10.3

390059MB RG59 B/U Mini Black 75 1/0.41 PCWB PE PVC 16 3.6

390059MW RG59 B/U Mini White 75 1/0.41 PCWB PE PVC 16 3.6

390059MBH RG59 B/U Mini Black LSHF 75 1/0.41 PCWB PE LSHF 16 3.6

390059MWH RG59 B/U Mini White LSHF 75 1/0.41 PCWB PE LSHF 16 3.6

390062 RG62 A/U 93 1/0.69 PCWB PESS PVC 60 6.2

390062H RG62 A/U LSHF 93 1/0.69 PCWB PESS LSHF 60 6.2

390062A RG62 A/U SWA 93 1/0.69 PCWB PESS PE 210 10.4

390108 RG108 Twin-Ax 78 2x7/0.32 TCWB PE PVC 48 5.9

390115 RG115 A/U 50 7/0.71 2 x SPCWB PTFE GFB 240 10.6

O/D

mm

YTC1

(Yellow)

Crimp tool 1 for RG58;

RG59; RG62; RG59 Mini

YTC2

(Green)

Crimp tool 2 for RG59;

CT100; CT125

YTC3

(Blue)

Crimp tool 3 for RG11;

RG213; CT125RBS BNC only

Low Smoke Halogen Free Duct Grade SWA CPR-Compliant Options Available

www.fscables.com | sales@fscables.com


RG Coaxial

129

SHEATH, DIELECTRIC AND SHIELD CODES

FEP Fluorinated Ethylene Propylene

FPE: Foamed Polyethylene

LDPE: Low Density Polyethylene

PTFE: PolyTetraFluoroEthylene

PESS: Polyethylene Semi Solid

TFE: TetraFluoroEthylene

PEAS: Polyethylene Air Spaced

PVC: Polyvinyl Chloride

PEC:

GFB:

SPCWB:

AFS:

TCWB:

PCWB:

AWB:

Polyethylene Cellular

Glass Fibre Braid

Silver Plated Copper Wire Braid

Aluminium Foil Screen

Tinned Copper Wire Braid

Plain Copper Wire Braid

Aluminium Wire Braid

Connectors

Description

Crimp

Plug

BNC F-Type N-Type N-Type

Crimp

Jack

Boots*

Crimp

Plug

Crimp

Jack

Crimp

Plug

Crimp

Jack

Crimp

Plug

Crimp

Jack

Crimp

Tool

RG6 Type YB1BC1 YB1BC2 - YB1FC1 YB1FC1 - - - - YTC2

RG6 Type LSHF YB1BC1 YB1BC2 - YB1FC1 YB1FC1 - - - - YTC2

RG6 Quad Shield - - - - - - - - - -

RG6 Quad Shield LSHF - - - - - - - - - -

RG8 Type 390L40EZCB1 - - - - 390L40EZCN1390L40EZCN2390L40EZCT1390L40EZCT2 390L40T1

RG8 Type LSHF 390L40EZCB1 - - - - 390L40EZCN1390L40EZCN2390L40EZCT1390L40EZCT2 390L40T1

RG11 A/U YA2BC1 YA2BC2 - YA2FC1 YA2FC2 YA2NC1 YA2NC2 - - YTC3

RG11 A/U LSHF YA2BC1 YA2BC2 - YA2FC1 YA2FC2 YA2NC1 YA2NC2 - - YTC3

RG11 A/U SWA YA2BC1 YA2BC2 - YA2FC1 YA2FC2 YA2NC1 YA2NC2 - - YTC3

RG58 C/U YA3BC1 YA3BC2 YA3BX700 - - YA3NC1 YA3NC2 YA3TC1 YA3TC2 YTC1

RG58 C/U LSHF YA3BC1 YA3BC2 YA3BX700 - - YA3NC1 YA3NC2 YA3TC1 YA3TC2 YTC1

RG58 C/U Duct YA3BC1 YA3 BC2 YA3BX700 - - YA3NC1 YA3NC2 YA3TC1 YA3TC2 YTC1

RG59 B/U LSF YA1BC1 YA1BC2 YA1BX7xx YA1FC1 YA1FC2 YA1NC1 YA1NC2 YA1TC1 YA1TC2 YTC1

RG59 B/U LSHF YA1BC1 YA1BC2 YA1BX7xx YA1FC1 YA1FC2 YA1NC1 YA1NC2 YA1TC1 YA1TC2 YTC1

RG59 B/U Duct YA1BC1 YA1BC2 YA1BX7xx YA1FC1 YA1FC2 YA1NC1 YA1NC2 YA1TC1 YA1TC2 YTC1

RG59 B/U SWA YA1BC1 YA1BC2 YA1BX7xx YA1FC1 YA1FC2 YA1NC1 YA1NC2 YA1TC1 YA1TC2 YTC1

RG59 B/U Mini Black YA8BC1 YA8BC2 YA8BX700 YA8FC1 YA8FC2 YA8NC1 YA8NC2 YA8TC1 YA8TC2 YTC1

RG59 B/U Mini White YA8BC1 YA8BC2 YA8BX704 YA8FC1 YA8FC2 YA8NC1 YA8NC2 YA8TC1 YA8TC2 YTC1

RG59 B/U Mini Black LSHF YA8BC1 YA8BC2 YA8BX700 YA8FC1 YA8FC2 YA8NC1 YA8NC2 YA8TC1 YA8TC2 YTC1

RG59 B/U Mini White LSHF YA8BC1 YA8BC2 YA8BX704 YA8FC1 YA8FC2 YA8NC1 YA8NC2 YA8TC1 YA8TC2 YTC1

RG62 A/U YA1BC1 YA1BC2 YA1BX7xx YA1FC1 YA1FC2 YA1NC1 YA1NC2 YA1TC1 YA1TC2 YTC1

RG62 A/U LSHF YA1BC1 YA1BC2 YA1BX7xx YA1FC1 YA1FC2 YA1NC1 YA1NC2 YA1TC1 YA1TC2 YTC1

RG62 A/U SWA YA1BC1 YA1BC2 YA1BX7xx YA1FC1 YA1FC2 YA1NC1 YA1NC2 YA1TC1 YA1TC2 YTC1

RG108 Twin-Ax - - - - - - - - - -

RG115 A/U - - - - - - - - - -

BNC PLUG

TO PLUG

BNC

CRIMP PLUG

BNC JACK

TO JACK

BNC JACK

F-TYPE

PLUG

N-TYPE

PLUG

N-TYPE JACK

*To show the colour of Boots required please replace xx in the part number with:

04 White 00 Black

Low Smoke Halogen Free Duct Grade SWA

Tel: 01727 840 841

COAXIAL


130

RG Coaxial

RG Coaxial

Originally developed for the American military the range of RG cables now has a wider use within the commercial

sectors. Most of the RG cables have been modified from the original military specification to increase their commercial

success. In some cases this is just a change to jacket or dielectric materials, in other cases its more fundamental,

changing braids and conductors. We are happy to provide full data sheets on the constructions of the cable we offer.

The most popular types are also kept in stock in both armoured and duct grade. For other types armoured, coloured or

duct grade versions can be easily supplied, often in quantities as low as 100m.

390213H

RG Coax Cable

Part No.

Description

Imp.

Ohms

Central

Cond.

Shield

Dielectric

Outer Weight

Sheath kg/km

390142 RG142 B/U 50 1/0.91 2 x SPCWB PTFE FEP 74 4.9

390165 RG165 50 7/0.81 SPCWB PTFE GFB 180 10.4

390174 RG174 A/U 50 7/0.16 TCWB PE PVC 16 2.6

390174H RG174 A/U LSHF 50 7/0.16 TCWB PE LSHF 16 2.6

390178 RG178 B/U 50 7/0.10 SPCWB PTFE FEP 10 1.8

390178DB RG178 B/U Double Braid 50 7/0.10 2 x SPCWB PTFE FEP 14 2.3

390179 RG179 B/U 75 7/0.10 SPCWB PTFE FEP 15 2.5

390179Y RG179 PVC 75 1/0.35 TCWB PE PVC 12 2.6

390179H RG179 LSHF 75 1/0.35 TCWB PE LSHF 12 2.6

390179YS RG179 Stranded PVC 75 7/0.12 TCWB PE PVC 12 2.6

390179HS RG179 Stranded LSHF 75 7/0.12 TCWB PE LSHF 12 2.6

390180 RG180 95 7/0.10 SPCWB PTFE FEP 29 3.7

390188 RG188 50 7/0.17 SPCWB PTFE FEP 17 2.5

390196 RG196 50 7/0.10 SPCWB PTFE FEP 9 2.0

390212 RG212 50 1/1.41 2 x SPCWB PE PVC 123 8.4

390213 RG213 /U 50 7/0.75 PCWB PE PVC 166 10.3

390213H RG213 /U LSHF 50 7/0.75 PCWB PE LSHF 166 10.3

390214 RG214 /U 50 7/0.75 2 x SPCWB PE PVC 173 10.8

390214H RG214 /U LSHF 50 7/0.75 2 x SPCWB PE LSHF 173 10.8

390216 RG216 75 7/0.40 2 x PCWB PE PVC 169 10.8

390216H RG216 LSHF 75 7/0.40 2 x PCWB PE LSHF 169 10.8

390218 RG218 50 1/4.95 PCWB PE PVC 658 22.0

390223 RG223 /U 50 1/0.90 2 x SPCWB PE PVC 49 5.4

390223H RG223 /U LSHF 50 1/0.90 2 x SPCWB PE LSHF 49 5.4

390225 RG225 50 7/0.79 2 x SPCWB PTFE GFB 268 10.9

390302 RG302 75 1/0.63 SPCWB PTFE FEP 4.7 5.3

390303 RG303 50 1/0.99 SPCWB PTFE FEP 47 5.3

390304 RG304 50 1/1.49 2 x SPCWB PTFE FEP 131 7.1

390316 RG316 50 7/0.17 SPCWB PTFE FEP 15 2.5

390316DB RG316 Double Braid 50 7/0.17 2 x SPCWB PTFE FEP 22 2.6

390393 RG393 50 7/0.80 2 x SPCWB PTFE FEP 245 10.0

390400 RG400 50 19/0.20 2 x SPCWB PTFE FEP 55 5.1

O/D

mm

YTC1

(Yellow)

Crimp tool 1 for

RG58; RG59; RG62;

RG59 Mini

YTC2

(Green)

Crimp tool 2 for

RG59; CT100;

CT125

YTC3

(Blue)

Crimp tool 3 for RG11;

RG213; CT125RBS

BNC only

We are also able to offer semi ridgid coaxes to RG401, RG402 and RG405. Call for more details.

Low Smoke Halogen Free

CPR-Compliant Options Available

www.fscables.com | sales@fscables.com


RG Coaxial

131

SHEATH, DIELECTRIC AND SHIELD CODES

FEP Fluorinated Ethylene Propylene

FPE: Foamed Polyethylene

LDPE: Low Density Polyethylene

PTFE: PolyTetraFluoroEthylene

PESS: Polyethylene Semi Solid

TFE: TetraFluoroEthylene

PEAS: Polyethylene Air Spaced

PVC: Polyvinyl Chloride

PEC:

GFB:

SPCWB:

AFS:

TCWB:

PCWB:

AWB:

Polyethylene Cellular

Glass Fibre Braid

Silver Plated Copper Wire Braid

Aluminium Foil Screen

Tinned Copper Wire Braid

Plain Copper Wire Braid

Aluminium Wire Braid

Connectors

Description

Crimp

Plug

BNC F-Type N-Type N-Type

Crimp

Jack

Boots*

Crimp

Plug

Crimp

Jack

Crimp

Plug

Crimp

Jack

Crimp

Plug

Crimp

Jack

Crimp

Tool

RG142 B/U - - - - - - - - - -

RG165 - - - - - - - - - -

RG174 A/U YA7BC1 YA7BC2 YA7BX7xx YA7FC1 - - - - - YTC1

RG174 A/U LSHF YA7BC1 YA7BC2 YA7BX7xx YA7FC1 - - - - - YTC1

RG178 B/U YC6BC1 - - - - - - - - -

RG178 B/U Double Braid YC6BC1 - - - - - - - - -

RG179 B/U YA7BC1 YA7BC2 YA7BX7xx YA7FC1 - - - - - YTC1

RG179 PVC YA7BC1 YA7BC2 YA7BX7xx YA7FC1 - - - - - YTC1

RG179 LSHF YA7BC1 YA7BC2 YA7BX7xx YA7FC1 - - - - - YTC1

RG179 Stranded PVC YA7BC1 YA7BC2 YA7BX7xx YA7FC1 - - - - - YTC1

RG179 Stranded LSHF YA7BC1 YA7BC2 YA7BX7xx YA7FC1 - - - - - YTC1

RG180 - - - - - - - - - -

RG188 - - - - - - - - - -

RG196 - - - - - - - - - -

RG212 - - - - - - - - - -

RG213 /U YA4BC1 YA4BC2 - - - YA4NC1 YA4NC2 YA4TC1 YA4TC2 390L40T1

RG213 /U LSHF YA4BC1 YA4BC2 - - - YA4NC1 YA4NC2 YA4TC1 YA4TC2 390L40T1

RG214 /U YA5BC1 YA5BC2 - - - YA5NC1 YA5NC2 - - YTC7

RG214 /U LSHF YA5BC1 YA5BC2 - - - YA5NC1 YA5NC2 - - YTC7

RG216 - - - - - - - - - -

RG216 LSHF - - - - - - - - - -

RG218 - - - - - - - - - -

RG223 /U YA6BC1 YA6BC2 - - - YA6NC1 YA6NC2 YA6TC1 YA6TC2 YTC1

RG223 /U LSHF YA6BC1 YA6BC2 - - - YA6NC1 YA6NC2 YA6TC1 YA6TC2 YTC1

RG225 - - - - - - - - - -

RG302 - - - - - - - - - -

RG303 - - - - - - - - - -

RG304 - - - - - - - - - -

RG316 YC4BC1 YC4BC2 - - - - - YC4TC1 YA4TC2 YTC1

RG316 Double Braid YC4BC1 YC4BC2 - - - - - YC4TC1 YA4TC2 YTC1

RG393 - - - - - - - - - -

RG400 YA6BC1 YA6BC2 - - - YA6NC1 YA6NC2 YA6TC1 YA6TC2 YTC1

BNC PLUG

TO PLUG

BNC

CRIMP PLUG

BNC JACK

TO JACK

BNC JACK

F-TYPE

PLUG

N-TYPE

PLUG

N-TYPE JACK

*To show the colour of Boots required please replace xx in the part number with:

04 White 00 Black

Low Smoke Halogen Free

Tel: 01727 840 841

COAXIAL


132

URM

URM Coaxial

The URM (Uni Radio-Metric) BS 2316 cables listed cover the majority of high frequency data and signal transmission

requirements. Other types can be supplied on request, as can armoured, duct grade or alternative sheath colours.

URM 70 is widely used for security applications connecting CCTV equipment where the stranded centre conductor is

less likely to break than the RG 59 type. This may be important where the camera pans and tilts. Other URM cables are

available to order.

391067

391070H

URM Coaxial Cable

Part No.

Description

Imp.

Ohms

Central

Cond.

Shield

Dielectric

Outer Weight

Sheath kg/km

391043 URM 43 50 1/0.81 PCWB PE PVC 40 5.0

391054 URM 54 50 7/0.19 2 x PCWB PE PVC 118 8.3

391057 URM 57 75 1/1.15 PCWB PE PVC 158 10.3

391065 URM 65 75 1/1.15 PCWB PE PVC 158 10.3

391067 URM 67 50 7/0.77 PCWB PE PVC 162 10.3

391067H URM 67 LSHF 50 7/0.77 PCWB PE LSHF 162 10.3

391070 URM 70 75 7/0.19 PCWB PE PVC 59 5.8

391070W URM 70 White 75 7/0.19 PCWB PE PVC 59 5.8

391070L URM 70 LSF 75 7/0.19 PCWB PE LSF 59 5.8

391070H URM 70 LSHF 75 7/0.19 PCWB PE LSHF 59 5.8

391070D URM 70 Duct 75 7/0.19 PCWB PE LDPE 72 8.0

391074 URM 74 50 1/4.78 PCWB PE PVC 710 22.0

391076 URM 76 50 7/0.32 PCWB PE PVC 41 5.1

391091 URM 91 50 7/0.76 2 x PCWB PE PVC 170 11.0

391095 URM 95 50 1/0.46 PCWB PE Nylon 13 2.3

391106 URM 106 75 1/0.65 SPCWB PTFE FEP 45 5.3

391109 URM 109 50 7/0.18 SPCWB PTFE FEP 14 2.4

391110 URM 110 50 7/0.11 SPCWB PTFE FEP 12 1.8

391111 URM 111 75 7/0.10 SPCWB PTFE FEP 14 2.4

391112 URM 112 50 7/0.76 2 x SPCWB PE PVC 176 11.0

391115 URM 115 50 1/0.90 2 x PCWB PE PVC 85 7.2

391202 URM 202 75 7/0.25 PCWB PEC PVC 85 5.1

O/D

mm

Low Smoke Halogen Free

Duct Grade

CPR-Compliant Options Available

www.fscables.com | sales@fscables.com


URM

133

SHEATH, DIELECTRIC AND SHIELD CODES

FEP Fluorinated Ethylene Propylene

FPE: Foamed Polyethylene

LDPE: Low Density Polyethylene

PTFE: PolyTetraFluoroEthylene

PESS: Polyethylene Semi Solid

TFE: TetraFluoroEthylene

PEAS: Polyethylene Air Spaced

PVC: Polyvinyl Chloride

PEC:

GFB:

SPCWB:

AFS:

TCWB:

PCWB:

AWB:

Polyethylene Cellular

Glass Fibre Braid

Silver Plated Copper Wire Braid

Aluminium Foil Screen

Tinned Copper Wire Braid

Plain Copper Wire Braid

Aluminium Wire Braid

Connectors

Description

Crimp

Plug

Crimp

Jack

BNC F-Type N-Type N-Type

Twist-on

Plug

Boots*

Crimp

Plug

Crimp

Jack

Crimp

Plug

Crimp

Jack

Crimp

Plug

Crimp

Jack

Crimp

Tool

URM 43 YA3BC1 YA3BC2 YA3BT1 YA3BX700 - - YA3NC1 YA3NC1 YA3TC1 YA3TC2 YTC1

URM 54 - - - - - - - - - - -

URM 57 - - - - - - - - - - -

URM 65 - - - - - - - - - - -

URM 67 YA4BC1 YA4BC2 - - - - YA4NC1 YA4NC2 YA4TC1 YA4TC2 YTC3

URM 67 LSHF YA4BC1 YA4BC2 - - - - YA4NC1 YA4NC2 YA4TC1 YA4TC2 YTC3

URM 70 YA1BC1 YA1BC2 YA1BT1 YA1BX7xx YA1FC1 YA1FC2 YA1NC1 YA1NC2 YA1TC1 YA1TC2 YTC1

URM 70 White YA1BC1 YA1BC2 YA1BT1 YA1BX7xx YA1FC1 YA1FC2 YA1NC1 YA1NC2 YA1TC1 YA1TC2 YTC1

URM 70 LSF YA1BC1 YA1BC2 YA1BT1 YA1BX7xx YA1FC1 YA1FC2 YA1NC1 YA1NC2 YA1TC1 YA1TC2 YTC1

URM 70 LSHF YA1BC1 YA1BC2 YA1BT1 YA1BX7xx YA1FC1 YA1FC2 YA1NC1 YA1NC2 YA1TC1 YA1TC2 YTC1

URM 70 Duct YA1BC1 YA1BC2 YA1BT1 - YA1FC1 YA1FC2 YA1NC1 YA1NC2 YA1TC1 YA1TC2 YTC1

URM 74 - - - - - - - - - - -

URM 76 - - - - - - - - - - -

URM 91 - - - - - - - - - - -

URM 95 - - - - - - - - - - -

URM 106 - - - - - - - - - - -

URM 109 YC4BC1 YC4BC2 - - - - - - YC4TC1 YC4TC2 YTC1

URM 110 - - - - - - - - - - -

URM 111 - - - - - - - - - - -

URM 112 - - - - - - - - - - -

URM 115 - - - - - - - - - - -

URM 202 - - - - - - - - - - -

BNC PLUG

TO PLUG

BNC

CRIMP PLUG

BNC JACK

TO JACK

BNC JACK

F-TYPE

PLUG

N-TYPE

PLUG

N-TYPE JACK

*To show the colour of Boots required please replace xx in the part number with:

04 White 00 Black

Tel: 01727 840 841

COAXIAL


134

WF Coaxial

WF Coaxial Cable

The CAI approved range of coaxial cables from Webro are recognised as the industry’s benchmark and the preferred

choice of the cable TV and satellite service providers around the UK for reliable, error-free communication.

All available with high quality, easy to use Cablecon F-Type connectors.

392100LCAI

WF Coaxial Cables

CONSTRUCTION

WF100: 1.00mm solid plain copper conductor,

foamed polyethylene dielectric, copper foil tape,

plain copper wire braid, PVC/LSF sheath.

WF125: 1.25mm solid plain copper conductor,

foamed polyethylene dielectric, copper foil tape,

plain copper wire braid, PVC/LSF sheath.

TECHNICAL INFORMATION

Impedance:

Capacitance:

Velocity of Prop: 81%

Temperature Rating:

75 ± 3ohm

WF100 - 55 pF/m

WF125 - 60 pF/m

Flexing -5°C to +70°C

Static -15°C to +70°C

Manufactured to: BS EN 50117

Flame Retardant: IEC/BS EN 60332-1-2

CAI Certificate No:

WF100 - 0116D

WF125 - 0142B

392100L5

Part No.

Description

Sheath

Material

Colour

Weight

kg/km

O/D

mm

392100LCAI WF100 PVC/LSF Black 49 6.5

392100L02CAI WF100 PVC/LSF Brown 49 6.5

392100L03CAI WF100 PVC/LSF Red 49 6.5

392100L09CAI WF100 PVC/LSF Yellow 49 6.5

392100L10CAI WF100 PVC/LSF Green 49 6.5

392100LWCAI WF100 PVC/LSF White 49 6.5

392100HCAI WF100 LSHF Black 49 6.5

392100H02CAI WF100 LSHF Brown 49 6.5

392100HWCAI WF100 LSHF White 49 6.5

392100L5 WF100 5 Core + 4mm² PVC/LSF Black 630 21.0

392125F5 WF125 5 Core + 4mm² PVC/LSF Black 710 24.0

We are also able to offer WF125, WF165, WF233 and WF340. Call for more details.

Low Smoke Halogen Free

CPR-Compliant Options Available

www.fscables.com | sales@fscables.com


TV Coaxial

135

TV Coaxial Cable

Originally developed to meet the needs of satellite installers, these cables complement the WF series.

These cables are also popular with other RF transmission users and applications, including long runs for 75 Ohm

camera systems, distribution of TV signals around hotels, conference centres and MDU, cables can also be armoured for

quantities as low as 100m.

TV100 Shotgun Coaxial Cable

CONSTRUCTION

Two 1.00mm solid plain copper conductor,

foamed polyethylene dielectric, copper foil tape,

plain copper wire braid, PVC/LSF outer sheath.

TECHNICAL INFORMATION

Impedance:

Capacitance:

75 ± 3ohm

55 pF/m

Velocity of Prop: 81%

Temperature Rating:

Static -15°C to +70°C

Flexing -5°C to +70°C

Manufactured to: BS EN 50117

392100FSHOTGUN

Part No.

Description

Sheath

Material

Colour

Weight

kg/km

O/D

mm

392100FSHOTGUN TV100 Shotgun PVC/LSF Black 95 6.5 x 12.8

TV100 Coaxial Cable

Part No.

Description

Sheath

Material

Colour

Weight

kg/km

O/D

mm

392100D TV100 Duct Grade PE Black 70 9.3

392100A TV100 Armoured SWA/PE Black 140 13.5

TV125 Coaxial Cable

CONSTRUCTION

1.25mm solid plain copper conductor, foamed polyethylene dielectric, copper foil tape, plain copper wire braid,

PE outer sheath.

Part No.

Description

Sheath

Material

Colour

Weight

kg/km

O/D

mm

392125F TV125 PE Black 58 7.8

392125H TV125 LSHF Black 58 7.8

392125D TV125 Duct Grade PE Black 90 10.6

392125A TV125 Armoured SWA/PE Black 160 12.0

392125D

TV167 Coaxial Cable

CONSTRUCTION

1.67mm solid plain copper conductor, foamed polyethylene dielectric, copper foil tape, plain copper wire braid,

PE outer sheath.

Part No.

Description

Sheath

Material

Colour

Weight

kg/km

O/D

mm

392167F TV167 PE Black 115 10.1

392167H TV167 LSHF Black 115 10.1

392167D TV167 Duct Grade PE Black 149 12.5

392167A TV167 Armoured SWA/PE Black 160 14.4

Low Smoke Halogen Free Duct Grade SWA

Tel: 01727 840 841

COAXIAL


136

Antennax Feeder Cables

Antennax Feeder Coax

Antennax ultra-low loss microwave cables are the ideal choice for LMR (Land Mobile Radio) communications, the

interconnection of transceivers, satellite & base stations.

Specifically designed to offer high performance across the bandwidth spectrum and sweep tested up to 5.8GHz they

offer a real advantage over traditional corrugated cables. The double-sided bonded and flexible braided design allows

Antennax cables to be used throughout the installation, removing the need for jumper cables which are traditionally

used to connect corrugated coax cables. With faster termination and reduced risk of kinking, installations can be

completed quicker with cost savings on materials and labour.

Typical applications for Antennax cables include LMR, mobile phone transmitters, broadband services, satellite antennas,

marine satellite systems, Wi-Fi, military, traffic control and terrestrial microwave.

The Antennax LSZH (Low Smoke Zero Halogen) versions have been tested to European flame retardant safety standards

and are widely used in the offshore industry for airborne broadband, satellite TV and point to point communications.

These cables are ideal where ultra-low loss and a superior performance is required replacing traditional corrugated coax

and “RG” types such as RG58, RG8, RG213, RG223 and RG214.

If you are looking for a great alternative to Times Microwave LMR ® cables or Commscope ® , Andrew ® , CNT ® , try

Antennax, exclusively available from FSC.

390L40H

Antennax 50 Ohm

Part No.

Cable Type

Sheath

Material

Size mm Weight kg/km O/D mm

390L19 ANT-195 UV PE 1/0.94 30 4.9

390L19H ANT-195H LSHF 1/0.94 30 4.9

390L20 ANT-200 UV PE 1/1.12 30 4.9

390L20H ANT-200H LSHF 1/1.12 30 4.9

390L24 ANT-240 UV PE 1/1.42 50 6.1

390L24H ANT-240H LSHF 1/1.42 50 6.1

390L30 ANT-300 UV PE 1/1.78 80 7.6

390L30H ANT-300H LSHF 1/1.78 80 7.6

390L40 ANT-400 UV PE 1/2.74 100 10.3

390L40H ANT-400H LSHF 1/2.74 100 10.3

390L60 ANT-600 UV PE 1/4.47 200 12.7

390L60H ANT-600H LSHF 1/4.47 200 12.7

Antennax 75 Ohm

Part No.

Cable Type

Sheath

Material

Size mm Weight kg/km O/D mm

390L20H75 ANT-200H LSHF 1/0.64 31 5.0

390L24H75 ANT-240H LSHF 1/0.82 49 6.1

390L40H75 ANT-400H LSHF 1/1.65 101 10.3

390L60H75 ANT-600H LSHF 1/2.74 201 15.0

Antennax 400 & 600 50 ohm & 75 ohm have been Independently

tested by BRE (Watford) and passed IEC/BS EN 60332-3-24C

Full technical datasheets and test reports are available for each

cable showing attenuation, return loss and resistance

Low Smoke Halogen Free

CPR-Compliant Options Available

www.fscables.com | sales@fscables.com


Antennax Connectors

137

Antennax Feeder Coax

The Antennax TM connectors are matched perfectly with the cables, minimise loss and provide easy termination either in

the field or on the assembly bench. To ensure reliable weatherproof terminations a full range of tools, boots, shrouds,

self amalgamating tapes and weatherproof PVC tape is also available.

If the connector type you need is not shown please ask us as we may well have added it to the range.

Connectors

BNC Crimp N-Type Crimp TNC Crimp SMA Crimp

Male Female Male Female

Right

Angle

Male

Male

Female

Reverse

Polarity

Male

Reverse

Polarity

Female

Male

Reverse

Polarity

Male

Reverse

Polarity

Female

Crimp

Tool

Stripping

Tool

390L19 390L19 390L19 390L19 390L19 390L19 390L19 390L19 390L19 390L19 390L19 390L19 390L24 390L24

EZCB1 CB2 EZCN1 EZCN2 CN3 CT1 CT2 CT6 CT7 CS1 CS6 CS7 T1 S1

390L20 390L20 390L20 390L20 390L20 390L20 390L20 390L20 390L20 390L20 390L20 390L20 390L24 390L24

CB1 CB2 CN1 CN2 CN3 CT1 CT2 CT6 CT7 CS1 CS6 CS7 T1 S1

390L24 390L24 390L24 390L24 390L24 390L24 390L24 390L24 390L24 390L24 390L24 390L24 390L24 390L24

CB1 CB2 EZCN1 CN2 CN3 CT1 CT2 EZCT6 EZCT7 CS1 CS6 CS7 T1 S1

390L30 390L30 390L30 390L30 390L30 390L30 390L30 390L30 390L30 390L30 390L30 390L30 390L30 390L30

CB1 CB2 CN1 CN2 CN3 CT1 CT2 CT6 CT7 CS1 CS6 CS7 T1 T1

390L40 390L40 390L40 390L40 390L40 390L40 390L40 390L40 390L40 390L40 390L40 390L40 390L40 390L40

EZCB1 CB2 EZCN1 EZCN2 CN3 EZCT1 EZCT2 EZCT6 EZCT7 CS1 CS6 CS7 T1 S1

- -

- -

- -

- -

- -

390L60 390L60 390L60 390L60 390L60 390L60 390L60

390L60 390L60

- - -

EZCN1 EZCN2 CN3 CT1 CT2 CT6 CT7 T1 EZS1

390L2075 390L2075 - 390L2075 390L2075

CN1 CN2 CT1 CT2

390L2475 390L2475 - 390L2475 390L2475

CN1 CN2 CT1 CT2

390L4075 390L4075 - 390L4075 390L4075

CN1 CN2 CT1 CT2

390L6075 390L6075 - 390L6075 390L6075

CN1 CN2 CT1 CT2

- - - - - - -

- - - - - - -

- - - - - - -

- - - - - - -

Tel: 01727 840 841

COAXIAL


138

Low Loss Coaxial Cables

Low Loss Coaxial Cables

When you install the FSC Low Loss Coaxial cables you can be confident you are installing quality. Using the latest

development and design techniques these products combine both high performance and low cost.

Through working closely with communication and service providers the product range covers almost every need. Fast

delivery and products that are engineered to last are just two of the reasons to specify or order from FSC.

Call us now to discuss your requirements in detail.

390AC1250

Corrugated Coax Series

Part No.

Alternative to

Andrew

Imp.

ohm

Inner

Cond. mm

Capitance

pF/m

Max.

Frequency GHz

Weight

kg/km

390AC1450 LDF1-50 1/4” 50 2.4 80.0 15.8 110 10.0

390AC1450H LDF1RK-50 1/4” LSHF 50 2.4 80.0 15.8 110 10.0

390AC3850 LDF2-50 3/8” 50 3.1 76.0 13.5 120 11.2

390AC3850H LDF2RK-50 3/8” LSHF 50 3.1 76.0 13.5 120 11.2

390AC1250 LDF4-50A 1/2” 50 4.8 76.0 8.8 220 16.2

390AC1250H LDF4RK-50A 1/2” LSHF 50 4.8 76.0 8.8 220 16.2

390AC1275 LDF4-75A 1/2” 75 3.0 50.5 10.0 210 16.0

390AC1275H LDF4RK-75A 1/2” LSHF 75 3.0 50.5 10.0 210 16.0

390AC7850 LDF5-50A 7/8” 50 9.3 74.0 5.0 510 27.8

390AC7850H LDF5RK-50A 7/8” LSHF 50 9.3 74.0 5.0 510 27.8

390AC7875 LDF5-75 7/8” 75 5.6 49.5 5.3 450 27.5

O/D

mm

Superflexible Series

Part No.

Alternative to

Andrew

Imp.

ohm

Inner

Cond. mm

Capitance

pF/m

Max.

Frequency GHz

Weight

kg/km

390ACF1450 FSJ1-50A 1/4” 50 1.9 82.0 20.4 70 7.8

390ACF1450H FSJ1RK-50B 1/4” LSHF 50 1.9 82.0 20.4 70 7.8

390ACF1475 FSJ1-75 1/4” 75 1.0 57.0 22.0 67 7.4

390ACF1475H FSJ1RK-75A 1/4” LSHF 75 1.0 57.0 22.0 67 7.4

390ACF3850 FSJ2-50 3/8” 50 2.6 82.0 13.4 120 10.2

390ACF3850H FSJ2RK-50 3/8” LSHF 50 2.6 82.0 13.4 120 10.2

390ACF1250 FSJ4-50B 1/2” 50 3.6 82.0 11.7 210 13.7

390ACF1250H FSJ4RK-50B 1/2” LSHF 50 3.6 82.0 11.7 210 13.7

390ACF1275 FSJ4-75A 1/2” 75 3.0 54.9 11.5 210 13.2

390ACF1275H FSJ4RK-75A 1/2” LSHF 75 3.0 54.9 11.5 210 13.2

O/D

mm

A full range of suitable connectors and accessories are available, please call for more details.

Low Smoke Halogen Free

CPR-Compliant Options Available

www.fscables.com | sales@fscables.com


Composite Coaxial

139

Composite Coaxial Cables

Composite cables including coax, power, signal or control are required for many CCTV applications, for example

heaters in camera housing to prevent misting. Control for pan, tilt & zoom (PTZ) and signal to carry audio are now all

commonplace requirements.

The FSC range of composite cable covers many applications. If you have a specific requirement, please call us, special

manufacture can be offered for quantities as low as 1000m.

Coax, Power + Signal Composite Cable

Part No.

Description

Coax Power Cores Signal Cores

Outer

Sheath

Colour

Weight

kg/km

390059L RG59 B/U - - LSF Black 60 6.1

390059H RG59 B/U - - LSHF Black 60 6.1

3900592L RG59 B/U 2 x 0.75mm² - LSF Black 115 6.1 x 12.0

3900592D RG59 B/U 2 x 0.75mm² - PE Black 125 6.1 x 12.0

39005922H RG59 B/U 2 x 1.5mm² 2 x 0.22mm² LSHF Black 185 11.5

39005922D RG59 B/U 2 x 1.5mm² 2 x 0.22mm² PE Black 225 13.9

3910702L URM 70 2 x 0.75mm² - LSF White 100 5.8 x 11.2

O/D

mm

39005922H

RG179 + RGB Composite Cable

Part No.

Coax

Description

Screen

Outer

Sheath

Colour

Weight

kg/km

390179Y3 3 x RG179 Unscreened PVC Black 63 7.4

390179Y4 4 x RG179 Overall Foil Screen PVC Black 85 8.3

390179Y5FS 5 x RG179 Overall Foil Screen PVC Black 104 9.4

390179Y5FHS 5 x RG179 Overall Foil Screen LSHF Grey 104 9.4

O/D

mm

392100C6H

Cat 6 UTP + TV100 Coaxial Shotgun Cable

Cat 6 UTP + TV 100 coax cable in shotgun format. This ‘one cable’ solution is perfect for running

network and satellite signals – ideal for MDU/hotel installations.

Where data needs to be carried outdoors, a tough weatherproof version is also stocked. Featuring

a PE (Polyethylene) outer jacket, this robust dual cable provides water resistance, UV stability and

extra durability while maintaining flexibility.

Part No.

Coax

Description

Data

Outer

Sheath

Colour

Weight

kg/km

392100C6 TV 100 Cat 6 UTP PVC Green 92 6.5 x 14.0

392100C6H TV 100 Cat 6 UTP LSHF Orange 92 6.5 x 14.0

392100C6C TV 100 Cat 6 UTP PE Black 92 6.5 x 14.0

O/D

mm

Low Smoke Halogen Free

Duct Grade

CPR-Compliant Options Available

Tel: 01727 840 841

COAXIAL


EXPORT REQUIREMENTS

OUR DEDICATED EXPORT TEAM IS ON HAND.

OFFERING A FAST AND COMPREHENSIVE

SERVICE, SUPPLYING YOU WITH EXPORT

PACKAGING, CABLES CUT TO LENGTH,

ESSENTIAL PAPERWORK AND CERTIFICATES.


141

Telephone

Introduction

Based on the British Telecom (BT) designs for

telephone cables the CW range covers all common

copper applications.

Internal cables in PVC or Low Smoke Halogen Free

(LSHF) versions are stocked from 2-100 pairs. Whilst

cables to be run outdoors either through ducts or

for direct burial are stocked alongside drop wire for

running between poles and buildings.

Most of the range is stocked on bulk drums and can

be cut to length to reduce wastage and save you

money.

Contents

CW1308 PVC Internal 142

CW1600 LSHF Internal 143

CW1128 External 144

CW1128/CW1198 External 145

CW1308B and Drop Wire 146

If you need telephone cable to European or ESI

specifications call us.

Tel: 01727 840 841

TELEPHONE


142

CW1308 PVC

CW1308 PVC Internal

Manufactured to British Telecom Specification CW1308, this cable is used for internal connection of telephone systems

and other communications equipment.

Insulated and sheathed in PVC, these cables offer an extremely cost effective general signal cable for fixed installation.

Standard sheath colour is white although some sizes are available in black or grey.

A full range of European specification telephone cables is also available on short lead times such as J-YY and J-Y(St)Y,

please call us with your requirements.

30810E

CONSTRUCTION

Solid copper conductor, colour coded

PVC insulation, twisted in pairs, rip

cord, PVC sheath.

In cables with over 10 pairs a cream

earth conductor may be included.

TECHNICAL INFORMATION

Conductor Diameter: 0.5mm Earth 1.38mm

Max. Conductor Resistance: 97.8 Ohm/km 12.4 Ohm/km

Max. Capacitance Unbalanced: 500pF/500m

Temperature Rating: Working 0°C to +70°C

Min. Bend Radius Fixed: 8 x cable diameter

Part No. No. of Pairs Weight kg/km O/D mm

30802 2 21 4.2

30803 3 28 5.0

30804 4 34 5.8

30806 6 44 6.8

30810 10 67 8.3

30810E 10+E 85 8.6

30820 20 150 10.7

30820E 20+E 183 12.0

30825 25 184 11.4

30830 30 226 12.2

30840E 40+E 371 15.0

30850E 50+E 427 17.0

30880E 80+E 610 22.5

308100E 100+E 708 27.0

308160E 160+E 1059 30.3

308200E 200+E 1393 33.1

308320E 320+E 1980 39.5

Other pair combinations or larger numbers of pairs and alternative conductor sizes are available on request.

Cables ending with E include a 1.38mm Earth core.

Colour code to BT Standard, see page 210.

CPR-Compliant Options Available

www.fscables.com | sales@fscables.com


CW1600 LSHF

143

CW1600 LSHF Limited Fire Hazard

Used for the internal wiring of buildings where the need to protect people and equipment from smoke and fumes is

paramount. CW1600 has the added advantage of an aluminium/polyester foil screen, drain wire and fire barrier tape.

This cable is similar in design and application to CW1308 but Low Smoke Halogen Free (LSHF) cores and sheath. A rip

cord is located directly under the jacket to make stripping the outer sheath easier.

CONSTRUCTION

Solid copper conductor, colour coded

Polyethylene insulation. Twisted into

pairs, screened with an aluminium/

polyester tape in contact with solid

copper drain wire, fire barrier tape,

LSHF sheath.

TECHNICAL INFORMATION

Conductor Diameter:

0.5mm

Max. Conductor Resistance: 97.8 Ohm/km

Max. Capacitance Unbalanced: 500pF/500m

Temperature Rating: Working 0°C to +70°C

Min. Bend Radius Fixed: 8 x cable diameter

Flame Retardant: IEC/BS EN 60332-1-2

BS EN 50266-2-4

BS EN 50266-2-5 Category C

Smoke Emission: IEC/BS EN 61034-2

Halogen Emission: BS EN 50267-2-1

60010

Part No. No. of Pairs Weight kg/km O/D mm

60003 3 35 5.0

60004 4 39 5.8

60006 6 66 6.9

60010 10 102 8.6

60020 20 167 12.0

60040 40 295 15.0

60050 50 358 18.0

600100 100 692 27.0

Colour code to BT Standard, see page 211.

All sizes are normally available from stock.

Armoured versions can be produced to order for quantities as low as 100m.

CPR-Compliant Options Available

Tel: 01727 840 841

TELEPHONE


144

CW1128

CW1128 External

CW1128 external telephone cables are suitable for installation outdoors where an armoured cable is not necessary. They

offer a lightweight, compact, tough solution for cables that will have to endure a variety of weather conditions, from

rain and snow to bright sunlight.

CW1128 is ideal for clipping around the outside of buildings or running through ducting. The outer sheath is made from

tough, durable polyethylene which is also UV and sunlight resistant. The pairs are bedded in petroleum jelly to protect

against the ingress of moisture.

12800520

CONSTRUCTION

Solid plain copper conductor, colour

coded polyethylene insulation,

petroleum jelly filled, separator tape

and a black polyethylene sheath.

TECHNICAL INFORMATION

Conductor Diameter: 0.5mm 0.9mm

Max. Conductor Resistance: 91 Ohm/km 28 Ohm/km

Insulation Resistance:

1500 Mohm/km 1500 Mohm/km

Capacitance Unbalanced: >3pair 275pF/m 275pF/m

Colour Code: see page 211 To CW1128 To CW1128

Solid 0.5mm Conductor

Part No. No. of Pairs Conductor Dia. mm Weight kg/km O/D mm

12800502 2 (Quad) 0.5 50 5.9

12800503 3 0.5 58 6.6

12800505 5 0.5 76 8.0

12800510 10 0.5 113 9.5

12800520 20 0.5 184 12.0

12800530 30 0.5 249 13.0

12800550 50 0.5 381 16.5

128005100 100 0.5 710 22.0

Solid 0.9mm Conductor

Part No. No. of Pairs Conductor Dia. mm Weight kg/km O/D mm

12800901Q 2 (Quad) 0.9 72 7.2

12800905 5 0.9 160 11.5

12800910 10 0.9 261 14.0

12800920 20 0.9 452 18.0

12800950 50 0.9 1076 26.5

128009100 100 0.9 2033 36.0

Aluminium screened/moisture barrier versions of this cable are also available in the style of CW1179 with some sizes

from stock. Please call to check availability.

Duct Grade

CPR-Compliant Options Available

www.fscables.com | sales@fscables.com


CW1128/CW1198

145

CW1128/1198 Armoured

CW1128/1198 type telephone cables are used for external connection of telephone systems and other communications

equipment where the added protection of steel wire armouring is needed. This cable is ideally suited for direct burial or

protection against rodents and vandalism.

The outer sheath is made from tough, durable polyethylene which is UV and sunlight resistant. The cores are bedded in

petroleum jelly to protect against the ingress of moisture.

CONSTRUCTION

Solid plain copper conductor, colour

coded polyethylene insulation,

petroleum jelly filled, separator tape,

polyethylene bedding, galvanised

steel wire armour and a black

polyethylene external grade sheath.

TECHNICAL INFORMATION

Conductor Diameter: 0.5mm 0.9mm

Max. Conductor Resistance: 91 Ohm/km 28 Ohm/km

Insulation Resistance:

1500 Mohm/km 1500 Mohm/km

Capacitance Unbalanced: >3pair 275pF/m 275pF/m

Colour Code: see page 211 To CW1128 To CW1128

19800520

Solid 0.5mm Conductor

Part No. No. of Pairs Conductor Dia. mm Weight kg/km O/D mm

19800501Q 2 (Quad) 0.5 187 10.1

19800505 5 0.5 218 13.2

19800510 10 0.5 285 14.7

19800520 20 0.5 378 17.2

19800550 50 0.5 896 23.3

198005100 100 0.5 1368 29.0

Solid 0.9mm Conductor

Part No. No. of Pairs Conductor Dia. mm Weight kg/km O/D mm

19800901Q 2 (Quad) 0.9 320 12.8

19800905 5 0.9 496 13.9

19800910 10 0.9 738 17.4

19800920 20 0.9 1257 23.6

19800950 50 0.9 2310 32.3

198009100 100 0.9 3487 40.6

Larger pair counts and screened or moisture barrier versions to CW1179 are also available. Please call to check

availability.

SWA

CPR-Compliant Options Available

Tel: 01727 840 841

TELEPHONE


146

CW1308B & Dropwire

CW1308B Internal/External

Originally developed for use on transport systems these cables have PVC insulation and a heavy black flame retardant

LSHF outer sheath. Due to the PVC insulation, we do not regard them as safe to use in high risk areas, however, they are

ideal for running in low rise buildings and externally when the alternative would be to joint the cable.

They also have a bonded heavy aluminium foil moisture barrier which can be earthed and used as a screen.

37804

CONSTRUCTION

Solid plain copper conductor,

colour coded PVC insulation, cores

twisted into pairs with a cream

earth conductor, bonded aluminium

laminated moisture barrier, LSHF

outer sheath.

TECHNICAL INFORMATION

Conductor Diameter: 0.5mm Earth 1.38mm

Max. Conductor Resistance: 97.8 Ohm/km 12.4 Ohm/km

Max. Capacitance Unbalanced: 500pF/500m

Temperature Rating: Working 0°C to +70°C

Minimum Bending Radius: 8 x cable diameter

Part No. No. of Pairs Weight kg/km O/D mm

308B10E 10 100 8.6

308B20E 20 160 12.0

308B30E 30 330 12.2

308B50E 50 620 18.0

308B100E 100 1030 27.0

308B160E 160 1140 30.3

308B200E 200 1200 32.0

308B320E 320 1725 39.5

Stocked on bulk drums these cables can be cut to the length required

Colour code to BT Standard, see page 210.

CW1415 & CW1411 & CW1420 Dropwire Cable

The FSC range of self supporting aerial cables is designed for use in local area networks to link

between pole and building or between two buildings. The brass coated PVC insulated high tensile

steel strainer wires are incorporated within the cable. A black polyethylene sheath (HDPE) which is

UV stable offers excellent weather resistance and service life.

1 pair Ref: CW1415 Colour code: Orange/White

2 pair Ref: CW1411 Colour code: Orange/White, Green/White

4 pair Ref: CW1420 Colour code: Orange/White, Green/White, Red/Grey, Blue/Brown

Part No. BT Ref No. of Pairs

Conductor

Dia. mm

Weight

kg/km

Nominal

O/D mm

37801 11 1 0.5 29 5.3

37802 10B 2 0.5 32 5.3

37804 15 4 0.5 35 5.4

Standard packing on Drop Wire is 350m reels.

CPR-Compliant Options Available

www.fscables.com | sales@fscables.com


147

Power

Introduction

The applications for power cables are immense. At

FSC we’ve built a stock of the most popular sizes

for low voltage power requirements. The two most

popular British types are BS5467, a PVC sheathed

armoured cable and its LSHF cousin BS6724. We

primarily stock Prysmian Draka, British made BASEC

approved, armoured cables.

The unarmoured German specification NYY power

cables are ideal when the cable is already protected

or doesn’t need protecting for example when it’s

used for low voltage or DC circuits. Alongside it

are the German LSHF range of N2XH unarmoured

power cables.

Contents

BS5467 PVC Armoured 148

BS6724 LSHF Armoured 149

NYY 150 & 151

N2XH 152 & 153

Safe-T-Shield 154

Safe-T-Shield is a Low Smoke Halogen Free (LSHF)

cable that is both lighter and quicker to install

than conventional armoured cables. It is ideal

for installations in partitions or stud work where

accidental puncture by a screw or nail could result

in electric shock. The heavy bonded Aluminium foil

safely earths the fault to the CPC.

Tel: 01727 840 841

POWER CABLES


148

BS5467 Armoured

BS5467 Armoured PVC Power Cables - 0.6/1kV

BS5467 cables are used for mains or low voltage power and control circuits. They offer excellent mechanical protection

from damage through the use of a heavy Galvanised Steel Wire Armour (GSWA). The GSWA and black PVC jacket

makes them suitable for use inside and outside buildings or for direct burial in the ground.

CONSTRUCTION

Plain copper conductors to BS EN 60228 class

2 (stranded), XLPE insulation, PVC inner sheath,

galvanised steel wire armour, black PVC sheath.

CORE IDENTIFICATION

2 Core Brown, Blue

3 Core Brown, Black, Grey

4 Core Brown, Black, Grey, Blue

5 Core Brown, Black, Grey, Blue, Green/Yellow

7 Core and above, including all sizes of auxiliary

cables - White cores with black numbering

TECHNICAL INFORMATION

Voltage Rating:

Conductor Stranding:

Temperature Rating:

Bending Radius:

0.6/1kV

BS EN 60228 class 2 shaped or circular

-15°C to +90°C max conductor temperature

6 x overall diameter

Flame Retardant: BS EN 60332-1-2

Manufactured To: BS5467 / IEC 60502

If a Low Smoke Halogen Free (LSHF) version is required please use BS6724 which

can be found on the page opposite.

54600103

Part No. Cores x mm 2 Weight kg/km Dia. over bedding O/D mm

54600102 2 x 1.5 305 7.0 10.8

54600103 3 x 1.5 338 7.4 11.2

54600104 4 x 1.5 381 8.4 11.9

54600105 5 x 1.5 426 8.9 12.9

54600105AUX 5 x 1.5 426 8.9 12.9

54600107 7 x 1.5 490 10.6 15.1

54600202 2 x 2.5 352 8.3 12.2

54600203 3 x 2.5 397 8.7 12.7

54600204 4 x 2.5 452 9.6 13.6

54600205 5 x 2.5 549 10.6 14.6

54600205AUX 5 x 2.5 549 10.6 14.6

54600207 7 x 2.5 600 12.5 17.0

54600402 2 x 4.0 419 9.3 13.3

54600403 3 x 4.0 481 9.9 13.9

54600404 4 x 4.0 563 10.9 14.9

54600405 5 x 4.0 810 12.0 16.3

54600405AUX 5 x 4.0 810 12.0 16.3

54600407 7 x 4.0 950 13.9 19.3

54600602 2 x 6.0 498 10.4 14.4

54600603 3 x 6.0 569 11.2 15.1

54600604 4 x 6.0 795 12.3 17.2

54600605 5 x 6.0 865 13.6 18.5

54601002 2 x 10* 764 12.0 16.2

54601003 3 x 10* 869 12.8 17.7

54601004 4 x 10* 1064 14.2 19.0

54601602 2 x 16* 900 14.1 19.0

54601603 3 x 16* 1159 15.1 20.1

54601604 4 x 16* 1410 16.6 21.8

*Circular or compacted circular stranded conductors (class 2) .

Weights and dimensions will vary from manufacturer, if critical please check at time of order.

Other conductor sizes and core counts available upon request.

CPR-Compliant Options Available

www.fscables.com | sales@fscables.com


BS6724 Armoured

149

BS6724 Armoured LSHF Power – 0.6/1kV

BS6724 mains voltage armoured power and control cables are manufactured using Low Smoke Halogen Free (LSHF)

compounds. This makes them ideal for use in public buildings, tunnels and areas of increased safety such as refineries

and power stations where mechanical damage and fire risk is a concern.

CONSTRUCTION

Plain copper conductors to BS EN 60228 class 2,

XLPE insulation, LSHF bedding, galvanised steel

wire armour, black LSHF sheath.

CORE IDENTIFICATION

2 Core Brown, Blue

3 Core Brown, Black, Grey

4 Core Brown, Black, Grey, Blue

5 Core Brown, Black, Grey, Blue, Green/Yellow

7 Core and above, including all sizes of auxiliary

cables - White cores with black numbering

TECHNICAL INFORMATION

Voltage Rating:

Conductor Stranding:

Temperature Rating:

Bending Radius:

Flame Retardant:

0.6/1kV

IEC/BS EN 60228 class 2 shaped or circular

-15°C to +90°C maximum conductor temperature

6 x overall diameter

IEC/BS EN 60332-1-2, IEC/BS EN 60332-3-24 cat C

Smoke Emission: IEC/BS EN 61034-2, BS EN 50268

Halogen Emission: IEC/BS EN 60754-1 & 2

Manufactured To: BS6724 / IEC 60502

We are also able to supply fire resistant versions such as Prysmian FP600S, Draka

FTP120 and Nexans NX600, see page 62.

Please specify sizes and quantity and if you require a specific manufacturer.

Part No. Cores x mm 2 Weight kg/km Dia. over bedding O/D mm

72400102 2 x 1.5 305 7.0 10.8

72400103 3 x 1.5 338 7.4 11.2

72400104 4 x 1.5 381 8.4 11.9

72400105 5 x 1.5 426 8.9 12.9

72400105AUX 5 x 1.5 426 8.9 12.9

72400107 7 x 1.5 490 10.6 15.1

72400202 2 x 2.5 352 8.3 12.2

72400203 3 x 2.5 397 8.7 12.7

72400204 4 x 2.5 452 9.6 13.6

72400205 5 x 2.5 549 10.6 14.6

72400205AUX 5 x 2.5 549 10.6 14.6

72400207 7 x 2.5 600 12.5 17.0

72400402 2 x 4.0 419 9.3 13.3

72400403 3 x 4.0 481 9.9 13.9

72400404 4 x 4.0 563 10.9 14.9

72400405 5 x 4.0 810 12.0 16.3

72400405AUX 5 x 4.0 810 12.0 16.3

72400407 7 x 4.0 950 13.9 19.3

72400602 2 x 6.0 498 10.4 14.4

72400603 3 x 6.0 639 11.2 15.1

72400604 4 x 6.0 795 12.3 17.2

72400605 5 x 6.0 865 13.6 18.5

72401002 2 x 10* 764 12.0 16.2

72401003 3 x 10* 908 12.8 17.7

72401004 4 x 10* 1064 14.2 19.0

72401602 2 x 16* 900 14.1 19.0

72401603 3 x 16* 1220 15.1 20.1

72401604 4 x 16* 1410 16.6 21.8

72400604

*Circular or compacted circular stranded conductors (class 2).

Weights and dimensions will vary from manufacturer, if critical please check at time of order.

Other conductor sizes and core counts are available upon request.

CPR-Compliant Options Available

Tel: 01727 840 841

POWER CABLES


150

NYY

NYY PVC/PVC Unarmoured Power – 0.6/1kV

NYY cables are an economical solution to power and control wiring where mechanical protection is not required.

Used both indoor and outdoor these cables are suitable for direct burial or can be run through ducts, local regulations

permitting. Originating in Germany they are now popular in many parts of the world where cost, weight and size savings

through not having an armour can offer many benefits. They are also easy to gland and terminate and require less

containment.

N0100107E

CONSTRUCTION

Plain copper wire conductors to IEC 60228

class 1 or 2, PVC insulation, bedding

compound, black PVC sheath.

TECHNICAL INFORMATION

Voltage Rating:

0.6/1kV

Conductor Stranding: ≤ 16 mm² solid. IEC 60228 class 1

Temperature Rating:

Bending Radius:

-30°C to +70°C fixed

-5°C to +70°C for installation

Single core 15 x overall diameter

Multicore 12 x overall diameter

Flame Retardant: VDE 0472 test B,

IEC/BS EN 60332-1-2

Manufactured To:

VDE 0276 pt 603 up to 5 core,

pt 627 for 7 core & above, IEC 60502

NYY can be supplied with a green/yellow earth conductor -

reference NYY-J or without an earth conductor – reference NYY-O.

CORE IDENTIFICATION

Type NYY-J with protective earth NYY-O without protective earth

1 Core Green/yellow Black

2 Core - Brown, Blue

3 Core Brown, Blue, G/Y earth Brown, Black, Grey

4 Core Brown, Black, Grey, G/Y earth Brown, Black, Grey, Blue

5 Core Brown, Black, Grey, Blue, G/Y earth Black, Blue, Brown, Grey, Black

7 Core and above Number coded with a G/Y earth Number coded

Part No.

NYY-J

Part No.

NYY-O

Cores x mm 2 Weight kg/km O/D mm

- N0100102 2 x 1.5 163 10.5

N0100103E N0100103 3 x 1.5 172 11.0

N0100104E N0100104 4 x 1.5 224 12.0

N0100105E N0100105 5 x 1.5 268 13.0

N0100107E N0100107 7 x 1.5 294 13.3

N0100110E N0100110 10 x 1.5 439 16.4

N0100112E N0100112 12 x 1.5 463 16.6

N0100114E N0100114 14 x 1.5 539 17.9

N0100116E N0100116 16 x 1.5 600 18.8

N0100119E N0100119 19 x 1.5 641 19.2

N0100121E N0100121 21 x 1.5 780 21.5

N0100124E N0100124 24 x 1.5 833 22.0

N0100130E N0100130 30 x 1.5 989 23.8

CPR-Compliant Options Available

www.fscables.com | sales@fscables.com


NYY

151

Part No.

NYY-J

Part No.

NYY-O

Cores x mm 2 Weight kg/km O/D mm

- N0100202 2 x 2.5 199 11.3

N0100203E N0100203 3 x 2.5 213 11.4

N0100204E N0100204 4 x 2.5 273 13.0

N0100205E N0100205 5 x 2.5 338 14.0

N0100207E N0100207 7 x 2.5 408 15.0

N0100210E N0100210 10 x 2.5 558 17.6

N0100212E N0100212 12 x 2.5 610 18.1

N0100214E N0100214 14 x 2.5 717 19.6

N0100216E N0100216 16 x 2.5 863 21.8

N0100219E N0100219 19 x 2.5 970 22.8

N0100221E N0100221 21 x 2.5 1012 23.4

N0100224E N0100224 24 x 2.5 1152 24.6

N0100230E N0100230 30 x 2.5 1398 26.9

N0100401E N0100401 1 x 4.0 105 7.9

- N0100402 2 x 4.0 294 13.4

N0100403E N0100403 3 x 4.0 340 14.0

N0100404E N0100404 4 x 4.0 354 15.1

N0100405E N0100405 5 x 4.0 459 15.8

N0100601E N0100601 1 x 6.0 132 8.5

- N0100602 2 x 6.0 361 14.4

N0100603E N0100603 3 x 6.0 426 15.1

N0100604E N0100604 4 x 6.0 515 16.3

N0100605E N0100605 5 x 6.0 595 17.3

N0101001E N0101001 1 x 10 180 9.4

- N0101002 2 x 10 479 15.9

N0101003E N0101003 3 x 10 580 16.8

N0101004E N0101004 4 x 10 716 18.3

N0101005E N0101005 5 x 10 836 19.5

N0101601E N0101601 1 x 16 245 10.3

- N0101602 2 x 16 661 18.0

N0101603E N0101603 3 x 16 814 19.0

N0101604E N0101604 4 x 16 1016 20.8

N0101605E N0101605 5 x 16 1230 22.7

N0100604E

Larger sizes up to 630mm² can be supplied cut to length on short lead-times, please call us with your specific

requirement.

‘E’ at the end of the part number indicates the cable contains an earth core included in the number of cores.

CPR-Compliant Options Available

Tel: 01727 840 841

POWER CABLES


152

N2XH

N2XH XLPE/LSHF Unarmoured Power – 0.6/1kV

N2XH is an unarmoured, Low Smoke Halogen Free (LSHF) power cable. Originating from Germany, it is now widely used

in much of Europe as a simple, easy to install 0.6/1kV power or control cable. It is the Low Smoke Zero Halogen and

flame-retardant version of NYY with solid conductors up to 16mm 2 and stranded or shaped conductors in larger sizes. In

applications where an armour is not needed, e.g. where the cable is not likely to suffer mechanical damage the weight

saving over armoured cable makes it ideal for indoor applications.

N0200107HE

CONSTRUCTION

Plain copper wire conductors to IEC 60228

class 1 or 2, XLPE insulation, bedding

compound, black LSHF sheath.

TECHNICAL INFORMATION

Voltage Rating:

0.6/1kV

Conductor Stranding: ≤ 16 mm² solid. IEC 60228 class 1

Temperature Rating:

Bending Radius:

-30°C to +70°C fixed

-5°C to +70°C for installation

Single core 15 x overall diameter

Multicore 12 x overall diameter

Flame Retardant: VDE 0472 test B, IEC 60332-1-2,

EN 60332-1-2

Manufactured To:

VDE 0276 pt 603 up to 5 core,

pt 627 for 7 core & above, IEC 60502

N2XH can be supplied with a green/yellow earth conductor -

reference N2XH-J or without an earth conductor – reference

N2XH-O.

CORE IDENTIFICATION

Type N2XH-J with protective earth N2XH-O without protective earth

1 Core Green/yellow Black

2 Core - Brown, Blue

3 Core Brown, Blue, G/Y earth Brown, Black, Grey

4 Core Brown, Black, Grey, G/Y earth Brown, Black, Grey, Blue

5 Core Brown, Black, Grey, Blue, G/Y earth Black, Blue, Brown, Grey, Black

7 Core and above Number coded with a G/Y earth Number coded

Part No.

N2XH-J

Part No.

N2XH-O

Cores x mm 2 Weight kg/km O/D mm

- N0200102H 2 x 1.5 163 10.5

N0200103HE N0200103H 3 x 1.5 173 11.0

N0200104HE N0200104H 4 x 1.5 224 12.0

N0200105HE - 5 x 1.5 268 13.0

N0200107HE - 7 x 1.5 294 13.3

N0200110HE - 10 x 1.5 439 16.4

N0200112HE - 12 x 1.5 463 16.6

N0200114HE - 14 x 1.5 539 17.9

N0200116HE - 16 x 1.5 600 18.8

N0200119HE - 19 x 1.5 641 19.2

N0200124HE - 24 x 1.5 833 22.0

N0200130HE - 30 x 1.5 989 23.8

CPR-Compliant Options Available

www.fscables.com | sales@fscables.com


N2XH

153

Part No.

N2XH-J

Part No.

N2XH-O

Cores x mm 2 Weight kg/km O/D mm

- N0200202H 2 x 2.5 199 11.3

N0200203HE N0200203H 3 x 2.5 213 11.4

N0200204HE N0200204H 4 x 2.5 273 13.0

N0200205HE - 5 x 2.5 338 14.0

N0200207HE - 7 x 2.5 408 15.0

N0200210HE - 10 x 2.5 558 17.6

N0200212HE - 12 x 2.5 610 18.1

N0200214HE - 14 x 2.5 717 19.6

N0200216HE - 16 x 2.5 863 21.8

N0200219HE - 19 x 2.5 970 22.8

N0200224HE - 24 x 2.5 1152 24.6

N0200230HE - 30 x 2.5 1398 26.9

- N0200402H 2 x 4.0 294 13.4

N0200403HE - 3 x 4.0 340 14.0

N0200404HE N0200404H 4 x 4.0 354 15.1

N0200405HE - 5 x 4.0 459 15.8

- N0200601H 1 x 6.0 132 8.5

- N0200602H 2 x 6.0 361 14.4

N0200603HE - 3 x 6.0 426 15.1

N0200604HE N0200604H 4 x 6.0 515 16.3

N0200605HE - 5 x 6.0 595 17.3

- N0201001H 1 x 10 180 9.4

- N0201002H 2 x 10 479 15.9

- N0201003H 3 x 10 580 16.8

N0201004HE N0201004H 4 x 10 716 18.3

N0201005HE - 5 x 10 836 19.5

- N0201601H 1 x 16 245 10.3

- N0201602H 2 x 16 661 18.0

- N0201603H 3 x 16 814 19.0

N0201604HE N0201604H 4 x 16 1016 20.8

N0201605HE - 5 x 16 1230 22.7

N0200604HE

Larger sizes up to 630mm² can be supplied cut to length on short lead-times, please call us with your specific

requirement.

‘E’ at the end of the part number indicates the cable contains an earth core included in the number of cores.

CPR-Compliant Options Available

Tel: 01727 840 841

POWER CABLES


154

Safe-T-Shield

Safe-T-Shield

Safe-T-Shield Low Smoke Halogen Free (LSHF) cable offers substantial advantages over conventional wiring methods.

It is ideal for fixed wiring in hospitals, airports, computer rooms and other sensitive environments. The high level of

screening ensures substantially reduced levels of electromagnetic interference (EMI) making it the right choice where

electromagnetic capability (EMC) is a priority.

Safe-T-Shield is manufactured and tested to the performance criteria of BS 8436. Because it is faster to install and lighter

than small armoured cables or conduit, cost savings of up to 40% can be achieved. Ideal for use behind partitions or in

stud work walls. If the cable is pierced or accidentally cut for example by a screw or nail the aluminium screen and CPC

minimise the chance of personal injury.

This cable is an alternative to Multi-Plus, Guardian & Afumex LSX.

38802502E

CONSTRUCTION

Plain copper wire strands to BS EN 60228

class 2, Halogen Free XLPE insulation

to BS7655-1.3, full size tinned copper

earth conductor to BS EN 13603:2002,

longitudinal aluminium tape, LSHF sheath to

BS EN 50267-2-1 & IEC/BS EN 61034-2.

TECHNICAL INFORMATION

Voltage Rating: 1.5mm² - 4mm² 300/500V

6mm² 600/1000V

Conductor Temp:

+70°C

Min. Installation Temp: -30°C

Sheath Colour:

Current Rating:

White, other colours on request

All cables have a full size bare earth

or CPC

Refer to IEE Regs table 4E2A

Flame Retardant: IEC/BS EN 60332-1-2

Smoke Emission: IEC/BS EN 61034-2

Halogen Emission:

Manufactured To:

IEC/BS EN 60754-1&2

BS8436 and BASEC Approved

Part No. Cores x mm 2 Conductor

Stranding/mm

Weight kg/km

O/D mm

38801502E 2 E 1.5 7/0.53 98 7.6

38801503E 3 E 1.5 7/0.53 135 8.4

38801504E 4 E 1.5 7/0.53 200 9.4

38802502E 2 E 2.5 7/0.67 140 8.5

38802503E 3 E 2.5 7/0.67 200 9.6

38802504E 4 E 2.5 7/0.67 220 10.5

38804002E 2 E 4.0 7/0.85 195 9.7

38804003E 3 E 4.0 7/0.85 240 11.0

38804004E 4 E 4.0 7/0.85 305 12.5

38806002E 2 E 6.0 7/1.04 280 12.3

38806003E 3 E 6.0 7/1.04 355 13.4

38806004E 4 E 6.0 7/1.04 430 16.2

Standard pack size 100m or 500m.

Available in black in some sizes, please put B after the part number when ordering. CPR-Compliant Options Available

www.fscables.com | sales@fscables.com


155

Rubber & Crane

Introduction

Where cables are exposed to the elements

or operating in harsh conditions, synthetic rubbers

can offer huge advantages. Neoprene or PCP is

now widely used as a sheathing material; it retains

flexibility over a wide temperature range and

has excellent abrasion resistance. Often used for

applications outdoors where water and weather

resistance is important, Neoprene offers many

advantages over PVC or other synthetic rubbers.

Crane, festoon and trailing cables are designed for

flexibility and durability and are unaffected by many

oils. FSC stock the popular sizes with others on

quick delivery times.

Contents

H07RN-F 156 & 157

WRAS Clean Water Cables 158 & 159

H05RR-F 160

Flat PVC 161

NSHTöu Drum Reeling 162

Also in this section are WRAS approved clean

water cables for use in fresh and drinking water

applications without risk of contamination.

Tel: 01727 840 841

RUBBER & CRANE


156

H07RN-F

H07RN-F Single & Multicores

The much heavier duty brother of H05RR-F these cables are 450/750V rated. Used extensively for trailing and flexible

supply leads in either single or multicore versions, these rubber cables remain flexible even at sub-zero temperatures.

H07RN-F uses neoprene (PCP) for its sheath. The improved abrasion resistance and the ability to withstand many oils and

chemicals make the neoprene sheathed cables suitable for the most arduous conditions.

Applications include portable saws, grinders, welders, pumps, transformers, as temporary lighting cable and feed cable to

heavy mobile equipment. Single cores and large multicores are often used as distribution cables from mobile generators.

57102507

CONSTRUCTION

Fine copper wire strands to BS EN

60228 class 5. Rubber insulation

colour coded to BS 7671/HD 308 S2

(cables with over 5 cores, A07RN-F,

are number coded). Cores twisted

together. Black neoprene (PCP) outer

sheath to BS 7919:2001.

TECHNICAL INFORMATION

Voltage Rating: Working 450/750V

Temperature Rating: -20°C to +60°C

+ 90°C for static applications

Bending Radius: Flexing 15 x cable diameter

Static 6 x cable diameter

Current Rating: H07RN-F Refer to IET Regs Table 4F1A&B

Conductor Stranding: BS EN 60228 Class 5 & VDE 0295 Class 5

Manufactured to: EN 50525-2-21

Part No. Cores x mm 2 Weight kg/km O/D mm

57101002 2 x 1.0 92 8.3

57101003 3 G 1.0 111 8.9

57101004 4 G 1.0 134 9.9

57101501 1 x 1.5 48 5.9

57101502 2 x 1.5 109 8.7

57101503 3 G 1.5 137 9.7

57101504 4 G 1.5 169 10.7

57101505 5 G 1.5 206 11.6

57101507 7 G 1.5 371 16.0

57101512 12 G 1.5 546 20.0

57101519 19 G 1.5 777 23.5

57101527 27 G 1.5 1090 27.5

57101537 37 G 1.5 1300 31.0

57102501 1 x 2.5 62 6.5

57102502 2 x 2.5 162 10.6

57102503 3 G 2.5 198 11.4

57102504 4 G 2.5 244 13.1

57102505 5 G 2.5 299 14.0

57102507 7 G 2.5 461 18.2

57102512 12 G 2.5 758 24.0

57102519 19 G 2.5 1100 24.5

57102527 27 G 2.5 1590 32.1

57104001 1 x 4.0 88 7.5

57104002 2 x 4.0 220 12.4

57104003 3 G 4.0 276 13.1

57104004 4 G 4.0 343 14.8

57104005 5 G 4.0 431 16.3

57106001 1 x 6.0 116 8.3

57106002 2 x 6.0 295 13.7

57106003 3 G 6.0 370 14.8

57106004 4 G 6.0 474 16.7

57106005 5 G 6.0 585 18.4

G = With Green/Yellow X = Without Green/Yellow CPR-Compliant Options Available

The overall diameter given has been taken from measuring actual cables, however, rubber cables vary considerably in diameter

from one manufacturer to another. If the diameter is critical, please ask at time of order and we will check the stock you will

be sent. Also available in a special blue sheathed version suitable for use in drinking water. See pages 158-159.

www.fscables.com | sales@fscables.com


H07RN-F

157

Part No. Cores x mm 2 Weight kg/km O/D mm

57110001 1 x 10 182 10.1

57110002 2 x 10 522 18.1

57110003 3 G 10 668 20.1

57110004 4 G 10 822 21.6

57110005 5 G 10 1010 24.2

57116001 1 x 16 250 11.4

57116002 2 x 16 738 21.6

57116003 3 G 16 906 22.6

57116004 4 G 16 1120 24.6

57116005 5 G 16 1380 27.1

57125001 1 x 25 361 13.4

57125003 3 G 25 1360 27.4

57125004 4 G 25 1730 30.7

57125005 5 G 25 2110 33.6

57135001 1 x 35 469 14.7

57135003 3 G 35 1700 29.7

57135004 4 G 35 2180 33.2

57135005 5 G 35 2680 41.3

57150001 1 x 50 671 17.5

57150003 3 G 50 2410 35.4

57150004 4 G 50 3060 39.2

57150005 5 G 50 4383 47.3

57170001 1 x 70 892 19.6

57170003 3 G 70 3180 39.6

57170004 4 G 70 4040 43.8

57170005 5 G 70 5398 56.2

57195001 1 x 95 1140 22.0

57195003 3 G 95 4070 45.2

57195004 4 G 95 5300 50.5

57112001 1 x 120 1420 24.2

57112003 3 G 120 4936 53.7

57112004 4 G 120 6499 59.5

57115001 1 x 150 1760 26.6

57115004 4 G 150 8101 65.5

57118501 1 x 185 2090 28.8

57118504 4 G 185 10029 76.5

57124001 1 x 240 2710 32.2

57130001 1 x 300 3310 34.9

57110003

G = With Green/Yellow X = Without Green/Yellow CPR-Compliant Options Available

The overall diameter given has been taken from measuring actual cables, however, rubber cables vary considerably in diameter

from one manufacturer to another. If the diameter is critical, please ask at time of order and we will check the stock you will

be sent. Also available in a special blue sheathed version suitable for use in drinking water. See pages 158-159.

Tel: 01727 840 841

RUBBER & CRANE


158

WRAS Clean Water Cables

WRAS Approved Clean Water Cables

Designed for power and control of submersible pumps these WRAS approved cables are perfect for drinking water

applications. These are jacketed using non-toxic and non-leaching cross-linked rubber, reducing the chance of aquatic

bacteria or other micro-organisms forming, they offer significant protection from potential health risks. But their uses don’t

stop there, any fresh or salt water, river, pond or stream is at risk from contamination, as are drinking fountains and food &

drink manufacturing facilities. At 0.6/1kV they will meet the same or a higher safety standard than many power cables.

59101504

CONSTRUCTION

Bare copper class 5 conductors to BS

EN 60228, cross linked polyethylene

insulation, cross linked rubber blue

sheath.

TECHNICAL INFORMATION

Voltage Rating: Working 0.6/1kV

Test 4000V

Temperature Rating: Static -40ºC to +80ºC

Flexing -25ºC to +50ºC

Conductor Stranding: BS EN 60228 Class 5

Insulation resistance: > 200 MΩ km

Maximum Temp in drinking water:

Halogen Gas Emission:

Approvals:

+40°C

IEC/BS EN 60754-1&2 &

EN 50267-2

WRAS, ACS, KTW, D.M.174.

& AD8 classification

Part No. Cores x mm 2 Weight kg/km O/D mm

59101003 3 G 1.0 82 8.6

59101004 4 G 1.0 102 9.5

59101503 3 G 1.5 106 9.7

59101504 4 G 1.5 130 10.6

59102501 1 x 2.5 53 6.2

59102503 3 G 2.5 149 10.9

59102504 4 G 2.5 186 12.0

59104001 1 x 4.0 69 7.0

59104003 3 G 4.0 214 12.4

59104004 4 G 4.0 272 13.6

59106001 1 x 6.0 93 7.7

59106003 3 G 6.0 292 13.9

59106004 4 G 6.0 377 15.4

59110001 1 x 10 138 9.1

59110003 3 G 10 459 16.8

59110004 4 G 10 588 18.5

G = With Green/Yellow X = Without Green/Yellow

Colour Code:

3 core Blue

4 core Brown

Brown Green/Yellow

Black Grey Green/Yellow

The overall diameter given has been taken from measuring actual cables, however, rubber cables vary considerably in

diameter from one manufacturer to another. If the diameter is critical, please ask at time of order and we will check the

stock you will be sent.

www.fscables.com | sales@fscables.com


WRAS Clean Water Cables

159

WRAS Approved Clean Water Cables

59116003

Part No. Cores x mm 2 Weight kg/km O/D mm

59116001 1 x 16 198 10.4

59116003 3 G 16 689 19.6

59116004 4 G 16 880 21.5

59125001 1 x 25 304 12.3

59125003 3 G 25 1060 23.9

59125004 4 G 25 1365 26.4

59135001 1 x 35 417 14.0

59135003 3 G 35 1385 27.0

59135004 4 G 35 1784 30.1

59150001 1 x 50 570 15.8

59150003 3 G 50 2012 31.3

59150004 4 G 50 2610 34.6

59170001 1 x 70 991 18.2

59170003 3 G 70 2640 35.8

59170004 4 G 70 3593 39.7

59195001 1 x 95 991 20.7

59195003 3 G 95 3500 41.9

59195004 4 G 95 4774 46.8

59112001 1 x 120 1234 23.0

59115001 1 x 150 1639 25.4

59118501 1 x 185 1994 27.4

59124001 1 x 240 2532 30.5

59130001 1 x 300 3350 34.0

G = With Green/Yellow X = Without Green/Yellow

Colour Code:

3 core Blue

4 core Brown

Brown Green/Yellow

Black Grey Green/Yellow

The overall diameter given has been taken from measuring actual cables, however, rubber cables vary considerably in

diameter from one manufacturer to another. If the diameter is critical, please ask at time of order and we will check the

stock you will be sent.

Tel: 01727 840 841

RUBBER & CRANE


160

H05RR-F

H05RR-F Multicores

Used extensively for trailing and flexible supply leads, these lightweight rubber cables remain flexible even at sub-zero

temperatures.

H05RR-F also known as TRS uses a standard grade rubber compound for the outer sheath and is suitable for light

duty applications.

Applications include light portable tools, temporary or portable lighting, extension leads for indoor or outdoor use where

there is minimal physical damage expected.

55101503

CONSTRUCTION

Fine copper wire strands to BS EN

60228 class 5. Rubber insulation

colour coded to BS 7671/HD 308 S2.

Cores twisted together. Black rubber

outer sheath.

TECHNICAL INFORMATION

Voltage Rating: Working 300/500V

Temperature Rating:

Bending Radius:

Current Rating:

-25°C to +60°C

Flexing 15 x cable diameter

Static 6 x cable diameter

H05RR-F Refer to IEE Regs Table 4HF3A&B

Conductor Stranding: To BS EN 60228 Class 5 & VDE 0295 Class 5

Manufactured to: EN 50525-2-21

Part No. Cores x mm 2 Weight kg/km O/D mm

55100702 2 x 0.75 58 6.6

55100703 3 G 0.75 74 7.1

55101002 2 x 1.0 69 7.1

55101003 3 G 1.0 84 7.6

55101004 4 G 1.0 107 8.1

55101502 2 x 1.5 105 8.5

55101503 3 G 1.5 123 8.9

55101504 4 G 1.5 155 9.9

55101505 5 G 1.5 190 11.0

55102502 2 x 2.5 148 10.2

55102503 3 G 2.5 181 10.5

55102504 4 G 2.5 228 11.7

55102505 5 G 2.5 280 13.1

G = With Green/Yellow X = Without Green/Yellow

The overall diameter given has been taken from measuring actual cables, however, rubber cables vary considerably in

diameter from one manufacturer to another. If the diameter is critical, please ask at time of order and we will check the

stock you will be sent.

H05RN-F is also available with a neoprene rubber sheath and rated at 300/500V. This is a tougher version of the

H05RR-F and ideal for portable tools.

CPR-Compliant Options Available

www.fscables.com | sales@fscables.com


Flat PVC Cables

161

Flat PVC Cables

Flat PVC cables offer good low-temperature durability, flexing to -15ºC. Their relatively light weight increases the options

available to designers as does the tight bending radius of 10 x the thickness of the cable. Used mainly on moving and

lifting equipment in a wide variety of applications. These cables are not suitable for use in elevators.

CONSTRUCTION

Fine copper wire strands to BS EN

60228 class 5. PVC insulation, colour

coded for cables with 2-5 cores, six

cores and above black with white

numbers. A green/yellow earth

conductor is included. Cores laid

parallel. Black cold resistant PVC

outer sheath.

TECHNICAL INFORMATION

Voltage Rating: 0.75 & 1.0mm 2 300/500V

1.5 - 50mm 2 450/750V

Temperature Rating:

Bending Radius:

Current Rating:

Flexing -15°C to +70°C

Flexing 10 x cable thickness

Refer to IEE Regs Table 4F3A&B

Conductor Stranding: BS EN 60228 Class 5

58101512

Part No. Cores x mm 2 Weight kg/km O/D mm

58100712 12 x 0.75 260 4.2 x 33.8

58100718 18 x 0.75 380 4.2 x 50.2

58100724 24 x 0.75 490 4.2 x 65.6

58101005 5 x 1.0 120 4.4 x 15.5

58101008 8 x 1.0 205 4.4 x 24.8

58101012 12 x 1.0* 335 9.5 x 22.5

58101016 16 x 1.0* 465 9.5 x 28.7

58101018 18 x 1.0 450 4.4 x 53.8

58101024 24 x 1.0 590 4.4 x 70.4

58101504 4 x 1.5 170 4.5 x 13.6

58101505 5 x 1.5 190 4.5 x 18.2

58101507 7 x 1.5 220 4.5 x 23.9

58101508 8 x 1.5 270 4.9 x 27.2

58101510 10 x 1.5 320 4.9 x 34.0

58101512 12 x 1.5 390 4.9 x 39.8

58101518 18 x 1.5 670 4.9 x 61.6

58101524 24 x 1.5 790 4.9 x 82.0

58102504 4 x 2.5 200 5.6 x 16.8

58102505 5 x 2.5 260 5.6 x 22.0

58102507 7 x 2.5 350 5.6 x 29.2

58102508 8 x 2.5 390 5.6 x 32.8

58102510 10 x 2.5 490 6.0 x 41.4

58102512 12 x 2.5 580 6.0 x 48.6

58102524 24 x 2.5 1200 6.0 x 104

58104004 4 x 4.0 320 7.0 x 21.2

58104005 5 x 4.0 400 7.0 x 27.4

58104007 7 x 4.0 540 7.0 x 36.6

58106004 4 x 6.0 432 8.2 x 24.8

58110004 4 x 10 680 10.0 x 29.6

58116004 4 x 16 970 11.2 x 34.4

58125004 4 x 25 1490 13.7 x 42.6

58135004 4 x 35 1980 15.4 x 47.6

58150004 4 x 50 2800 18.2 x 57.5

* Cores can be laid in Quad Format or Flat, please check at time of enquiry.

Low Smoke Halogen Free (LSHF) versions, other core combinations and individually screened cores are

available on request. Please call us with your requirements.

Tel: 01727 840 841

RUBBER & CRANE


162

NSHTöu

NSHTöu Drum Reeling

NSHTöu is designed specifically for drum reeling applications. On anything from dockside cranes to automated conveyor

systems, NSHTöu copes with incredible workloads. Good UV and weather resistance makes the cable suitable for exposed

outdoor installation.

A special low temperature type is available to work down to -40°C. Other sizes and high tensile versions using Kevlar

strain relief elements are also available. Medium and high voltage variants are available usually with red PCP outer

sheaths.

51106004

CONSTRUCTION

Fine copper wire strands to BS EN 60228. Rubber

insulation, 4 & 5 core colour coded, six core and

above, black with white numbers. Green/yellow

earth core in all cables. Cores twisted together

with short lay length. Black neoprene (PCP) dual

layer outer sheath with integral textile braid.

TECHNICAL INFORMATION

Voltage Rating:

Temperature Rating:

Bending Radius:

Working 0.6/1kV

Flexing -25°C to +60°C

Up to 20mm diameter:

10 x cable diameter

Flexing above 20mm diameter:

12.5 x cable diameter

Part No. Cores x mm 2 Weight

kg/km

O/D

mm

51101504 4 x 1.5 301 15.0

51101505 5 x 1.5 342 16.0

51101507 7 x 1.5 419 20.0

51101512 12 x 1.5 620 22.0

51101518 18 x 1.5 875 27.0

51101524 24 x 1.5 1020 29.0

51101530 30 x 1.5 1362 31.0

51101542 42 x 1.5 1724 35.0

51102504 4 x 2.5 374 17.0

51102505 5 x 2.5 486 19.0

51102507 7 x 2.5 506 22.0

51102508 8 x 2.5 704 24.0

51102512 12 x 2.5 891 26.0

51102516 16 x 2.5 1103 28.0

51102518 18 x 2.5 1208 30.0

51102519 19 x 2.5 1282 31.0

51102524 24 x 2.5 1562 35.0

51102530 30 x 2.5 1819 36.0

51102536 36 x 2.5 2327 40.0

51102542 42 x 2.5 2860 45.0

Part No. Cores x mm 2 Weight

kg/km

O/D

mm

51104004 4 x 4.0 526 19.0

51104005 5 x 4.0 636 21.0

51104008 8 x 4.0 1015 27.0

51106004 4 x 6.0 688 21.0

51106005 5 x 6.0 855 23.0

51110004 4 x 10 1047 26.0

51110005 5 x 10 1190 28.0

51116004 4 x 16 1280 29.0

51116005 5 x 16 1803 32.0

51125004 4 x 25 2102 35.0

51135004 4 x 35 2751 39.0

51150004 4 x 50 3695 45.0

51170004 4 x 70 5401 49.0

51195004 4 x 95 6985 57.0

51112004 4 x 120 8294 60.0

51115004 4 x 150 8989 65.0

51301525* 25x1.5+5x1.5(C) 2142 40.0

51302519* 19x2.5+5x1.5(C) 1757 34.0

51302525* 25x2.5+5x1.5(C) 2010 37.0

51501506 3 x (2 x 1.5)(C) 608 23.0

51501512 6 x (2 x 1.5)(C) 984 31.0

* The 5 x 1.5mm 2 signal cores are individually screened.

Also available are PUR-H versions which feature a polyurethane, halogen free sheath. Please call with your requirements.

www.fscables.com | sales@fscables.com


163

High Temperature

Introduction

High temperature or heat resistant cables are

stocked up to 750°C. The most popular range use

silicone as an insulating material and as a sheath on

the multicore versions. With an operating window

between -50°C to +180°C silicone is an extremely

flexible material. Stocked up to 185mm² in single

core and 25mm² in multicore they may well be the

solution to your temperature related needs.

Thermocouples or compensating & extension cables

are used for temperature measurement. If you need

single or multipair, screened or unscreened, solid or

stranded, call us for a solution.

Contents

Silicone Single Cores 164 & 165

Silicone Multicores 166 & 167

PTFE Single Cores 168

P-Temp 260 169

G-Temp 600 170

Thermocouple Cables 171 & 172

If you want to go higher, PTFE works well up to

260°C with glass braided G-Temp designed to cope

with 750°C.

Very large stocks are held of many sizes and colours

and most are available on a cut to length basis. Call

us to discuss your specific heat related cabling needs

– we probably have the one you want in stock.

Tel: 01727 840 841

HIGH TEMPERATURE


164

Silicone Single Cores

Silicone SiF, SiF-GL, SiD Single Cores

Silicone insulated conductors offer you an economical solution to many temperature related wiring problems. Capable

of working at extremes as far apart as -50°C right up to +180°C, silicone insulated cables have grown substantially in

popularity. Flexibility is retained even at very low temperatures where conventional rubber or PVC cable would become

brittle and crack.

At high temperatures, applications include heating elements, lighting, manufacturing and food processing and for

control circuits where heat is involved. At low temperatures silicone insulated cables are used in cold stores and

refrigeration plants for lighting, portable equipment and motor feeds.

45104000

TECHNICAL INFORMATION

Voltage Rating: Working 300/500V

Temperature Rating: Flexing -25°C to +180°C Static -50°C to +180°C

SiD Static -50°C to +180°C

Bending Radius: Flexing 15 x cable diameter Static 7.5 x cable diameter

SiD Static 7.5 x cable diameter

Current Rating:

Refer to IEE Regs Table 4F2A&B

Conductor Stranding: Flexible cables To BS EN 60228 Class 5 & VDE 0295 Class 5

SiD To BE EN 60228 Class 1 & VDE 0295 Class 1

Most of the silicone insulated cables on the following page are available from stock in standard pack sizes of

100m or 500m. For conductor sizes above 10mm 2 , the cable can be cut to the length you require.

Other voltages, strandings and approvals available on request.

SiF CONSTRUCTION

Fine tinned copper wire strands, class 5 flexible, silicone insulation in various colours.

SiF Flexible

Part No. Size mm 2 Weight

kg/km

O/D

mm

451002xx 0.25 5 1.9

451005xx 0.50 8 2.1

451007xx 0.75 11 2.4

451010xx 1.0 13 2.5

451015xx 1.5 18 2.8

451025xx 2.5 30 3.4

451040xx 4.0 48 4.2

451060xx 6.0 71 4.9

451100xx 10 120 6.7

451160xx 16 187 7.4

451250xx 25 289 9.2

Part No. Size mm 2 Weight

kg/km

O/D

mm

451350xx 35 399 10.3

451500xx 50 559 12.2

451700xx 70 766 14.2

451950xx 95 1032 16.6

451120xx 120 1285 18.0

451150xx 150 1565 20.0

451185xx 185 1915 22.5

451240xx 240 2550 25.2

451300xx 300 3190 28.0

451400xx 400 4130 36.3

451510xx 500 5210 40.3

To show the colour required please replace xx in the part number with:

00 Black

01 Blue

02 Brown

03 Red

04 White

05 Grey

06 Violet

07 Pink

08 Orange

09 Yellow

10 Green

99 Green/Yellow

www.fscables.com | sales@fscables.com


Silicone Single Cores

165

SiD CONSTRUCTION

Solid tinned copper wire strands, class 1 solid, silicone insulation in various colours.

44101003

SiD Solid

Part No. Size mm 2 Weight

kg/km

O/D

mm

441005xx 0.50 9 2.0

441007xx 0.75 13 2.2

441010xx 1.0 15 2.3

441015xx 1.5 21 2.6

Part No. Size mm 2 Weight

kg/km

O/D

mm

441025xx 2.5 34 3.2

441040xx 4.0 52 3.9

441060xx 6.0 71 4.6

SiF-GL CONSTRUCTION

Fine tinned copper wire strands, class 5 flexible, silicone insulation. Impregnated glass fibre braid.

In various colours.

SiF-GL Glass Braided

Part No. Size mm 2 Weight

kg/km

O/D

mm

46100204 0.25 8 2.1

46100504 0.50 11 2.5

461007xx 0.75 14 2.8

461010xx 1.0 16 2.9

461015xx 1.5 22 3.2

461025xx 2.5 34 3.8

46104004 4.0 53 4.6

46106004 6.0 76 5.4

Part No. Size mm 2 Weight

kg/km

O/D

mm

46110004 10 137 7.6

46116004 16 200 8.4

46125004 25 300 10.2

46135004 35 400 11.3

46150004 50 550 13.4

46170004 70 750 15.4

46195004 95 1000 17.8

SiF-HT CONSTRUCTION

Flexible tinned copper wire strands, class 5, silicone high voltage insulation.

46102504

SiF-HT High Voltage

Part No. Size mm 2 Volts kV O/D mm Colour

45201000 1.0 7.5 7.0 Red

45501004 1.0 10 7.0 White

45301003 1.0 5.0 5.0 Red

SiF-G-Si-HT CONSTRUCTION

Flexible tinned copper wire strands, class 5, silicone high voltage insulation, glass fibre braid, blue silicone sheath.

SiF-G-Si-HT High Voltage

Part No. Size mm 2 Volts kV O/D mm Colour

45601000 1.0 16 8.0 Blue

45601500 1.5 16 8.5 Blue

To show the colour required please replace xx in the part number with:

00 Black

01 Blue

02 Brown

03 Red

04 White

05 Grey

06 Violet

07 Pink

08 Orange

09 Yellow

10 Green

99 Green/Yellow

Tel: 01727 840 841

HIGH TEMPERATURE


166

Silicone Multicores

Silicone SiHF, SiHFP, SiHF-C-Si Multicores

Silicone insulated and sheathed multicore cables offer electrical engineers and specifiers a superb range of options.

Ideally suited to high or low temperature applications, these cables will work between -50°C and +180°C. When

exposed to fire they produce minimal smoke or fumes.

Silicone is a relatively soft material and is easily cut, a tougher version EWKF is available to special order, otherwise

suitable protection should be allowed for. Options include a galvanised steel wire braid for mechanical protection or a

tinned copper wire braid for screening against EMI.

Applications within the industry include plastic forming and moulding, packaging, food processing, refrigeration,

furnaces and lighting. Also used within spa and sauna facilities and domestic heating and cooking equipment.

47101503

TECHNICAL INFORMATION

Voltage Rating: Working 300/500V

Temperature Rating: Flexing -25°C to +180°C Static -50°C to +180°C

Bending Radius SiHF: Flexing 15 x cable diameter Static 7.5 x cable diameter

Braided Cables: Flexing 20 x cable diameter Static 10 x cable diameter

Current Rating:

Refer to IEE Regs Table 4F2A&B and 4F3A&B

Conductor Stranding: To BS EN 60228 Class 5 & VDE 0295 Class 5

SiHF CONSTRUCTION

Fine tinned copper wire strands with silicone rubber insulation. Cores twisted together. Reddish brown silicone

rubber outer sheath. (Some sizes available with black or white sheaths or an overall glass fibre braid).

47101512

SiHF

Part No.

Cores x

mm 2

Weight

kg/km

O/D mm

47100702 2 x 0.75* 60 6.3

47100703 3 x 0.75* 71 6.8

47100704 4 x 0.75 91 7.7

47100705 5 x 0.75 114 8.5

47101002 2 x 1.0 67 6.6

47101003 3 x 1.0* 81 7.0

47101004 4 x 1.0 104 8.0

47101005 5 x 1.0 130 9.0

47101006 6 x 1.0 153 9.7

47101007 7 x 1.0 161 9.8

47101502 2 x 1.5 92 7.6

47101503 3 x 1.5* 111 8.0

47101504 4 x 1.5 137 9.0

47101505 5 x 1.5 167 9.7

47101506 6 x 1.5 197 10.5

47101507 7 x 1.5 208 10.5

47101508 8 x 1.5 242 11.5

47101510 10 x 1.5 316 13.2

47101512 12 x 1.5 371 14.1

47101518 18 x 1.5 549 17.2

47101524 24 x 1.5 741 20.0

Part No.

Cores x

mm 2

Weight

kg/km

O/D mm

47102502 2 x 2.5 131 8.8

47102503 3 x 2.5* 171 9.7

47102504 4 x 2.5 212 10.6

47102505 5 x 2.5 258 11.8

47102507 7 x 2.5 324 12.7

47102512 12 x 2.5 581 17.3

47104002 2 x 4.0 200 10.8

47104003 3 x 4.0 248 11.5

47104004 4 x 4.0 310 12.6

47104005 5 x 4.0 386 14.1

47104007 7 x 4.0 502 15.8

47106002 2 x 6.0 275 12.4

47106003 3 x 6.0 344 13.0

47106004 4 x 6.0 439 14.7

47106005 5 x 6.0 556 16.4

47110004 4 x 10 731 19.5

47116004 4 x 16 1043 21.3

47125004 4 x 25 1621 26.6

47135004 4 x 35 2146 29.5

* Also available from stock with a black or white sheath.

www.fscables.com | sales@fscables.com


Silicone Multicores

167

SiHFP CONSTRUCTION

Fine tinned copper wire strands with silicone rubber insulation. Cores twisted together. Reddish brown silicone

rubber sheath. Glass fibre tape with an overall galvanised steel wire braid.

48102504E

SiHFP

Part No.

Cores x

mm 2

Weight

kg/km

O/D mm

48100702 2 x 0.75 94 7.5

48100703 3 x 0.75 105 7.9

48100704 4 x 0.75 125 8.6

48100705 5 x 0.75 157 9.7

48100706 6 x 0.75 176 10.2

48100707 7 x 0.75 182 10.2

48101002 2 x 1.0 101 7.8

48101003 3 x 1.0 115 8.2

48101004 4 x 1.0 146 9.0

48101005 5 x 1.0 173 9.8

48101007 7 x 1.0 203 10.7

48101502 2 x 1.5 126 8.8

48101503 3 x 1.5 154 9.2

48101504 4 x 1.5 180 9.9

48101505 5 x 1.5 209 10.8

48101506 6 x 1.5 248 11.6

48101507 7 x 1.5 259 11.6

48101508 8 x 1.5 301 12.4

48101512 12 x 1.5 457 15.1

48101518 18 x 1.5 646 18.5

48101524 24 x 1.5 855 21.3

Part No.

Cores x

mm 2

Weight

kg/km

O/D mm

48102502 2 x 2.5 174 9.9

48102503 3 x 2.5 214 10.9

48102504 4 x 2.5 263 11.8

48102505 5 x 2.5 317 12.8

48102507 7 x 2.5 588 13.9

48102512 12 x 2.5 679 18.5

48104002 2 x 4.0 251 11.9

48104003 3 x 4.0 308 12.8

48104004 4 x 4.0 369 13.8

48104005 5 x 4.0 472 15.3

48104007 7 x 4.0 588 17.1

48106002 2 x 6.0 334 13.5

48106003 3 x 6.0 418 14.5

48106004 4 x 6.0 525 15.8

48106005 5 x 6.0 654 17.9

48110004 4 x 10 845 20.8

48116004 4 x 16 1171 22.7

48125004 4 x 25 1785 27.9

48101512

SiHF-C-Si CONSTRUCTION

Fine tinned copper wire strands with silicone rubber insulation. Cores twisted together. Reddish brown silicone

rubber inner sheath or polyester tape. Tinned copper wire braid. Reddish brown silicone rubber sheath.

SiHF-C-Si

Part No.

Cores x

mm 2

Weight

kg/km

O/D mm

49100702 2 x 0.75 135 9.1

49100703 3 x 0.75 148 9.5

49100704 4 x 0.75 179 10.1

49100705 5 x 0.75 210 10.7

49100707 7 x 0.75 247 11.6

49100712 12 x 0.75 357 14.8

49101002 2 x 1.0 149 9.4

49101003 3 x 1.0 162 9.7

49101004 4 x 1.0 209 10.3

49101005 5 x 1.0 240 11.2

49101007 7 x 1.0 281 11.9

Part No.

Cores x

mm 2

Weight

kg/km

O/D mm

49101502 2 x 1.5 191 10.6

49101503 3 x 1.5 212 11.0

49101504 4 x 1.5 247 11.9

49101505 5 x 1.5 286 13.2

49101507 7 x 1.5 332 14.2

49101512 12 x 1.5 536 18.0

49102502 2 x 2.5 241 12.0

49102503 3 x 2.5 290 12.9

49102504 4 x 2.5 334 14.2

49102505 5 x 2.5 398 15.4

49102507 7 x 2.5 466 16.8

Tel: 01727 840 841

HIGH TEMPERATURE


168

PTFE Single Cores

PTFE Single Cores BS 3G 210

PTFE is a remarkable material. It is unaffected by most oils, fuels and fluids. The high-temperature range makes it

resistant to damage from heat sources such as soldering irons or components.

These cables are manufactured to BS 3G 210 and operate up to +200°C or +250°C short term with silver plated copper

conductors. Nickel plated conductor versions to work up to +260°C are available to special order. Other standards

available include American Mil, VDE, DIN and Lloyds.

Multicore and screened or braid armoured versions can also be manufactured in many sizes and styles.

Please note due to the manufacturing process this cable may be supplied in multiple lengths on a reel. For example,

100m may be made up of two or more lengths. This is common to all manufacturers using the Ram extrusion process.

BSG31819B01

TECHNICAL INFORMATION

Voltage Rating: Working Type A 300V Test: 2500V

Type B 600V Test: 3400V

Type C 1000V Test: 5000V

Temperature Rating: Static -55°C to +200°C Short term +250°C

Bending Radius: Static 6 x cable diameter

Conductor Material:

Silver plated copper

Manufactured to BS 3G 210.

BSG31419C04

Part No.

AWG

Stranding

mm

CSA

mm 2

Voltage

Grade

Weight

kg/km

min

O/D mm

BSG33007Axx 30 7/0.10 0.056 A 1.1 0.50 0.65

BSG32807Axx 28 7/0.12 0.089 A 1.4 0.56 0.71

BSG32807Bxx 28 7/0.12 0.089 B 2.1 0.76 0.96

BSG32607Axx 26 7/0.15 0.14 A 1.7 0.65 0.80

BSG32607Bxx 26 7/0.15 0.14 B 3.09 0.85 1.05

BSG32407Axx 24 7/0.20 0.22 A 3.04 0.80 0.95

BSG32407Bxx 24 7/0.20 0.22 B 3.89 1.00 1.20

BSG32407Cxx 24 7/0.20 0.22 C 4.64 1.26 1.52

BSG32219Axx 22 19/0.15 0.35 A 4.41 0.95 1.10

BSG32219Bxx 22 19/0.15 0.35 B 5.44 1.15 1.35

BSG32219Cxx 22 19/0.15 0.35 C 6.43 1.41 1.67

BSG32019Axx 20 19/0.20 0.61 A 7.19 1.20 1.35

BSG32019Bxx 20 19/0.20 0.61 B 8.43 1.40 1.60

BSG32019Cxx 20 19/0.20 0.61 C 9.08 1.66 1.92

BSG31819Bxx 18 19/0.25 0.96 B 12.1 1.65 1.85

BSG31819Cxx 18 19/0.25 0.96 C 14.3 1.91 2.17

BSG31619Cxx 16 19/0.30 1.23 C 16.5 2.16 2.46

BSG31419Cxx 14 19/0.36 1.94 C 23.9 2.34 2.74

BSG31219Cxx 12 19/0.45 3.08 C 38.5 2.91 3.31

BSG31037Cxx 10 37/0.40 4.65 C 56 3.46 3.86

max

To show the colour required please replace xx in the part number with:

00 Black

01 Blue

02 Brown

03 Red

04 White

05 Grey

06 Violet

07 Pink

08 Orange

09 Yellow

10 Green

99 Green/Yellow

www.fscables.com | sales@fscables.com


P-Temp 260

169

P-Temp 260

P-Temp 260 cables are designed to operate at conductor temperatures up to +260°C. The PTFE insulation is covered by

a layer of mica that is protected from abrasion or mechanical damage by an impregnated and varnished glass fibre braid.

The cable is also capable of withstanding higher temperatures for short periods. This is a direct alternative to In-Temp

250 that used to be manufactured by BICC.

The fine stranded nickel plated copper conductor provides flexibility during installation and routing with substantially

improved high temperature performance over tinned or plain copper.

Multicore versions can be made to your requirements normally with stainless steel or glass fibre braids. Other types of

PTFE insulated wires are also available with tinned, nickel, or silver plated conductors. Please ask for details.

CONSTRUCTION

Fine nickel plated copper wire strands to BS EN

60228 Class 5 or finer. White PTFE insulation. Mica

tape. Impregnated and varnished glass fibre braid.

Standard colour white, other colours to special

order.

TECHNICAL INFORMATION

Voltage Rating:

Temperature Rating:

Bending Radius:

Working 0.6/1kV

Test 5000V

Static -55°C to +260°C

Static 10 x cable diameter

Conductor Stranding: To BS EN 60228 class 5

flexible or finer

76002500

Part No. Size mm 2 Stranding

x mm

Weight kg/km O/D mm Current amps*

76001000 1.0 32 x 0.20 22 3.2 25

76001500 1.5 30 x 0.25 30 3.6 40

76002500 2.5 50 x 0.25 39 3.9 54

76004000 4.0 56 x 0.30 56 4.7 74

76006000 6.0 84 x 0.30 80 6.1 98

76010000 10 133 x 0.30 120 6.9 135

76016000 16 126 x 0.40 193 8.7 180

76025000 25 196 x 0.40 287 10.2 240

76010000

*Current rating at +80°C ambient for conductor temperature of +250°C.

Up to 25mm² held in stock. Larger sizes or multicores are available to order.

We also hold stocks of some sizes of Unipren, Uniefglas, Uniminyvin, Uninyvin and Unitersil. Please ask for details.

Tel: 01727 840 841

HIGH TEMPERATURE


170

G-Temp 600

G-Temp 600

Pure nickel conductors offer excellent high temperature performance. The conductor can withstand temperatures up

to +750°C. The high temperature glass insulation enables the nickel conductor to operate continuously at +600°C

and for short periods up to +750°C. Applications include furnaces, ovens, kilns and other extremely high-temperature

environments. For use in dry conditions only.

These cables can also be supplied in multicore versions with overall glass fibre or stainless steel braids for quantities as

low as 100m.

Higher voltages are available by special order. These include a mica tape in the cable construction. Please call if you have

a specific requirement.

78504056

CONSTRUCTION

Pure nickel strands, double glass yarn lapped,

impregnated, glass braided, double silicone

varnished, colour Natural/White.

TECHNICAL INFORMATION

Voltage Rating:

Temperature Rating:

Working 250V

Continuous +600°C

Intermittent +750°C

Part No.

Size

mm 2

Stranding

x mm

Lug

Type

Weight

kg/km

O/D

mm

Current ratings in Amps

at +30°C Ambient.

Conductor Temp.

+180°C +200°C +250°C

78500516 0.50 16/0.20 A 9 2.0 5 6 7.5

78500724 0.75 24/0.20 A 11 2.3 6 7 9

78501032 1.0 32/0.20 A 16 2.5 9 9 10

78501530 1.5 30/0.25 B 22 2.7 15 16 17

78502550 2.5 50/0.25 B 32 3.3 21 22 23

78504056 4.0 56/0.30 C 46 3.9 26 28 29

78506084 6.0 84/0.30 C 59 5.2 31 33 34

NICKEL CRIMP LUGS

Copper is not suitable for crimp lugs at very high temperatures due to its greater expansion rate. This can result

in nickel conductors simply dropping out.

We are able to offer high temperature stable crimp lugs that will work at over +800ºC designed to match the

FSC G-Temp-600.

Part No.

Lug Type

Conductor Size

Stud Size

Max

Length

Max

Width

Min Max

LUGN02/1/4 A 0.25mm 2 1.0mm 2 4mm 14.8 6.8

LUGN10/2/4 B 1.0mm 2 2.5mm 2 4mm 16.4 8.3

LUGN20/6/4 C 2.5mm 2 6.0mm 2 4mm 20.0 9.9

www.fscables.com | sales@fscables.com


Thermocouple Cables

171

Thermocouple and Compensating Cables

A thermocouple cable is typically a pair of insulated conductors made from two different metals with the same or similar

properties to the thermocouple probe. They carry the signal from the probe back to the measuring unit. To transmit the

signal there must be a positive (+) and negative (-) conductor. These conductors are often referred to as legs. Two legs

make a pair and you must have a pair for a thermocouple to operate. Multiple pair cables are also used where a number

of sensors or probes in one area link back to a control panel. Cables can be supplied as standard measurement industry

designs or to specific standards including BS 5308, IEC 60092 and EN 50288-7. RTD (PT-100) cables can also be supplied

in three core versions.

Selecting your thermocouple cable:

To choose a suitable cable please view the following sections and the appropriate materials to meet your needs. When you have

chosen your thermocouple cable please email the completed pages or call us with the information and we will provide you with a quote

and lead time.

International Colour Codes for Thermocouple Cable

Cable Type

EUROPEAN

BS 4937 Part 30

IEC 60584

BRITISH

BS 1843

AMERICAN

ANSI MC96.1

GERMAN

DIN 43710.4

Extension Cables

KX

Nicro

Nial

+

+

+

+

+

+

+

+

+

+

+

+

+

+

+

+

+

+

+

+

JX

TX

EX

NX

Iron

Constantan

Copper

Constanan

Nicro

Constanan

Nicrosil

Nisil

Compensating Cables

KCB

Compensation

for Type K

(was Vx)

RCA/

SCA

Compensation

for Type R or S

Copper

Constantan

Copper

Cupronic

+

+

+

+

+

+

+

+

Tel: 01727 840 841

HIGH TEMPERATURE


172

Thermocouple Cables

Number of Pairs

Quantity Required (m)

Insulation material options

Material Operating Temperature Properties

PVC -30°C to +70°C General usage

PVC-HT -20°C to +105°C High temperature applications

XLPE -30°C to +90°C Low Smoke Halogen Free

XLPE + Mica -30°C to +90°C Fire resistant barrier (IEC 60331-21)

Silicone -60°C to +180°C High temperature applications

FEP -100°C to +205°C Chemical & heat resistant

PFA -190°C to +260°C Chemical & heat resistant

PTFE -190°C to +260°C Chemical & heat resistant

Glass -50°C to +600°C Dry environments only

Screening options

Not Required

Collective Screen Options

Aluminium/polyester foil & drain wire

Tinned copper braid

Silver plated copper braid

Nickel plated copper braid

Sheathing and bedding materials

Individual Screen Options

Individual & collective aluminium/polyester foil & drain wires

Individual aluminium/polyester & drain wire, each pair jacketed

Ind & collective aluminium/polyester foil & drain wires + TCu braid

Individual tinned copper braids

Not Required

Sheathing Bedding Material Operating Temperature Properties

PVC -30°C to +70°C General usage

PVC-HT -20°C to +105°C High temperature applications

LDPE -50°C to +70°C Water resistant

LSHF -30°C to +90°C Low Smoke Halogen Free

Tri-Barrier (Ali/HDPE/PA) -50°C to +70°C Hydrocarbon resistant barrier

Silicone -60°C to +180°C High Temperature applications

FEP -100°C to +205°C Chemical & heat resistant

PFA -190°C to +260°C Chemical & heat resistant

PTFE -190°C to +260°C Chemical & heat resistant

Glass -50°C to +600°C Dry environments only

Armour protection

Not Required

Material Operating Temperature Properties

GSWA Galvanised Steel Wire Armour Mechanical protection

GSWB Galvanised Steel Wire Braid Flexibility for installation in confined areas

GSTA Galvanised Steel Tape Armour Mechanical protection

CWB Copper Wire Braid armour Mechanical protection (mainly offshore)

SSWB Stainless Steel Wire Braid Armouring for very high temperature cables

Conductor size & stranding options

Size mm² Strands mm Strands mm Strands mm AWG/Strands

0.22 1/0.51 7/0.20 - 24/7

0.44 1/0.37 7/0.28 13/0.20 22/7

0.50 1/0.80 7/0.30 16/0.20 20/7

0.75 1/0.97 7/0.37 24/0.20 18/16

1.0 1/1.13 7/0.43 32/0.20 18/7

1.5 1/1.38 7/0.53 30/0.25 16/19

www.fscables.com | sales@fscables.com


173

Bus

Introduction

Prior to bus systems being developed each switch,

sensor, detector or contact needed wiring back to

the process controller via its own pair or cable. Bus

systems changed that, instead of using a dedicated

pair, signals are coded and sent over a common bus

cable which connects all the equipment together

allowing the sensors and detectors to communicate

between each other as well as back to the

controller.

The use of bus technology has expanded into almost

every industry from controlling manufacturing

lines through to building automation which has

seen a growth in proprietary systems aimed at

specific applications. Each system has its own cable

specifically designed to optimise efficiency and

speed allowing us to measure, detect and control

almost anything and everything!

Contents

Foundation Fieldbus 174

Profibus 175

DeviceNet & CAN Bus 176

Echelon LonWorks & Interbus 177

Modbus & ASI Bus 178

Industrial Ethernet, CC-Link,

Piltz & Sensalink

179

The bus cables in this section cover the most

popular types however we are constantly adding

to the range as new systems are developed. If

you need a bit of help or cannot see the type you

require please call us, it’s likely we have an option

in stock.

Tel: 01727 840 841

BUS


174

Foundation Fieldbus

1801PODF

Foundation Fieldbus Cables

Foundation Fieldbus is primarily used in the process control automation industry and is an open

protocol, all digital, serial, two-way communication system which interconnects devices at speeds

of 31.25kB/s. Carrying signals between different devices is simpler because of the twisted pair

cable design. Due to the open Fieldbus network, all products interoperate.

Foundation Fieldbus Type A

Part No.

Alt. to

Belden

No. of

Pairs

AWG

Screen

Sheath

Material

Weight

kg/km

O/D

mm

Sheath

Colour

1801PODF 1334A 1 18(7) Foil & Braid PVC 75 8.0 Blue

1801PODFH LSHF 1 18(7) Foil & Braid LSHF 75 8.0 Blue

1801PODFD DUCT 1 18(7) Foil & Braid PE 91 10.4 Black

1801PODFA SWA 1 18(7) Foil & Braid PE 283 12.0 Black

1802PTFPH N/A 2 18(7) Ind. & Ovrl. Foil LSHF 128 9.8 Orange

1805PTFPH N/A 5 18(7) Ind. & Ovrl. Foil LSHF 262 16.7 Orange

1802PTFPHA SWA 2 18(7) Ind. & Ovrl. Foil LSHF 382 14.8 Black

1805PTFPHA SWA 5 18(7) Ind. & Ovrl. Foil LSHF 735 18.1 Black

1801POFO 3076F 1 18(7) Foil PVC 51 7.4 Orange

1801POFOH 3076F LSHF 1 18(7) Foil LSHF 51 7.4 Orange

1801POFOA 3076F SWA 1 18(7) Foil PE 221 10.4 Black

Foundation Fieldbus Type B

1801POFOH

A single pair 22AWG bi-directional digital Fieldbus cable for type B applications (31.25 KBits/sec)

available in PVC, LSHF and SWA versions.

Part No.

Alt. to

Belden

No. of

Pairs

AWG

Screen

Sheath

Material

Weight

kg/km

O/D

mm

Sheath

Colour

2201POFO 3077F 1 22(7) Foil PVC 29 4.9 Orange

2201POFOH 3077F LSHF 1 22(7) Foil LSHF 29 4.9 Orange

2201POFOA 3077F SWA 1 22(7) Foil PE 213 8.1 Black

Foundation Fieldbus High Speed

A high speed single pair 22AWG bi-directional digital Fieldbus cable for 1.0 & 2.5MBit/sec

applications available in PVC, LSHF and SWA versions.

Part No.

Alt. to

Belden

No. of

Pairs

AWG

Screen

Sheath

Material

Weight

kg/km

O/D

mm

Sheath

Colour

2201POFF 3078F 1 22(7) Foil PVC 65 9.4 Orange

2201POFFH 3078F LSHF 1 22(7) Foil LSHF 65 9.4 Orange

2201POFFA 3078F SWA 1 22(7) Foil PE 287 12.6 Black

Low Smoke Halogen Free Duct Grade SWA CPR-Compliant Options Available

www.fscables.com | sales@fscables.com


Profibus

175

Profibus Cables

2201PODF

A range of single pair Bus cables for process and field communication in cellular networks. The

Profibus protocol has been widely adopted for production and process automation applications

providing transmission rates up to 12Mbits/sec.

Profibus DP

Part No.

Alt. to

Belden

No. of

Pairs

AWG

Screen

Sheath

Material

Weight

kg/km

O/D

mm

Sheath

Colour

2201PODF 3079A 1 22(1) Foil & Braid PVC 61 8.0 Violet

2201PODFHQ 3079A LSHF 1 22(1) Foil & Braid LSHF 61 8.0 Violet

2201POFPD 3079A Duct 1 22(1) Foil & Braid PE 88 9.5 Black

2201PODFHA 3079A SWA 1 22(1) Foil & Braid PE 188 11.5 Black

2201PODFHF 3079A High-Flex 1 22(7) Foil & Braid PUR 78 8.3 Violet

Profibus PA

A single pair 18AWG bi-directional digital Fieldbus cable for type A applications (31.25 KBits/sec)

available in PVC, LSHF and SWA versions.

Part No.

Alt. to

Belden

No. of

Pairs

AWG

Screen

Sheath

Material

Weight

kg/km

O/D

mm

Sheath

Colour

1801PODF 1334A 1 18(7) Foil & Braid PVC 75 8.0 Blue

1801PODF00 1334A 1 18(7) Foil & Braid PVC 75 8.0 Black

1801PODFH LSHF 1 18(7) Foil & Braid LSHF 75 8.0 Blue

1801PODFH00 LSHF 1 18(7) Foil & Braid LSHF 75 8.0 Black

1801PODFD DUCT 1 18(7) Foil & Braid PE 91 10.4 Black

1801PODFA SWA 1 18(7) Foil & Braid PE 283 12.0 Black

1801POFOIS 3076F 1 18(7) Foil PVC 60 7.4 Blue

1801POFOHIS 3076F LSHF 1 18(7) Foil LSHF 60 7.4 Blue

1801POFOIS

Profibus PA - Long Distance

Part No.

Alt. to

Belden

No. of

Pairs

AWG

Screen

Sheath

Material

Weight

kg/km

O/D

mm

Sheath

Colour

1601PODF N/A 1 16(7) Foil & Braid PVC 130 9.6 Black

1601PODFIS N/A 1 16(7) Foil & Braid PVC 130 9.6 Blue

1401PODF N/A 1 14(7) Foil & Braid PVC 136 11.7 Black

1401PODFIS N/A 1 14(7) Foil & Braid PVC 136 11.7 Blue

Low Smoke Halogen Free Duct Grade SWA CPR-Compliant Options Available

Tel: 01727 840 841

BUS


176

DeviceNet & CAN Bus

15ABDY

DeviceNet

Designed for use on Allen Bradley DeviceNet systems, the ‘thick’ cable construction incorporates a

power and data pair for backbone wiring. ‘Thin’ cables are designed to connect sensors, actuators

and switches to the DeviceNet backbone (thick cable) on the Allen Bradley DeviceNet system.

Similar in construction to the backbone cable, the ‘thin’ cable incorporates a power and data pair.

Several sheathing options are available for different installation environments. These cables are also

referred to as DeviceNet Trunk and Drop cables.

28100502

DeviceNet Thick Cables

Part No. Alt. to Belden Description

Sheath

Material

Weight

kg/km

O/D

mm

15ABDY 3082A 1pair 15awg + 1pair 18awg PVC 174 12.2

15ABDH 3082A LSHF 1pair 15awg + 1pair 18awg LSHF 174 12.2

15ABDR 3083A 1pair 15awg + 1pair 18awg CPE 174 12.1

15ABDYD 3082A Duct 1pair 15awg + 1pair 18awg PE 220 14.4

15ABDYA 3082A SWA 1pair 15awg + 1pair 18awg PE 359 16.1

15ABDYHF 3082A Hi-Flex 1pair 15awg + 1pair 18awg PUR 209 12.1

DeviceNet Thin Cables

Part No. Alt. to Belden Description

Sheath

Material

Weight

kg/km

O/D

mm

22ABDY 3084A 1pair 22awg + 1pair 24awg PVC 65 7.0

22ABDH 3084A LSHF 1pair 22awg + 1pair 24awg LSHF 65 7.0

22ABDR 3085A 1pair 22awg + 1pair 24awg CPE 68 7.1

22ABDYD 3084A Duct 1pair 22awg + 1pair 24awg PE 80 9.2

22ABDYA 3084A SWA 1pair 22awg + 1pair 24awg PE 240 11.9

22ABDYHF 3084A Hi-Flex 1pair 22awg + 1pair 24awg PUR 64 7.0

CAN Bus

CAN Bus (Control Area Network) is a non-addressable system which treats all devices as equal

allowing for fast transmission of data. Due to its robust nature, it has been widely adopted in the

automotive industry.

Part No. No. of Pairs CSA mm 2 Sheath

Material

Weight

kg/km

O/D

mm

Sheath

Colour

28100201Y 1 0.22 PVC 41 5.2 Violet

28100202Y 2 0.22 PVC 60 6.2 Violet

28100301Y 1 0.34 PVC 53 6.5 Violet

28100302Y 2 0.34 PVC 64 6.8 Violet

28100501Y 1 0.50 PVC 67 7.1 Violet

28100502Y 2 0.50 PVC 75 7.6 Violet

28100701Y 1 0.75 PVC 105 8.5 Violet

28100702Y 2 0.75 PVC 120 9.3 Violet

CAN Bus for Dynamic Applications

Part No. No. of Pairs CSA mm 2 Sheath

Material

Weight

kg/km

O/D

mm

Sheath

Colour

28100201 1 0.22 PUR 41 5.2 Violet

28100202 2 0.22 PUR 60 6.2 Violet

28100301 1 0.34 PUR 53 6.5 Violet

28100302 2 0.34 PUR 64 6.8 Violet

28100501 1 0.50 PUR 67 7.1 Violet

28100502 2 0.50 PUR 75 7.6 Violet

28100701 1 0.75 PUR 105 8.5 Violet

28100702 2 0.75 PUR 120 9.3 Violet

Low Smoke Halogen Free Duct Grade SWA

www.fscables.com | sales@fscables.com


Echelon LonWorks & Interbus

177

Echelon LonWorks

2202POFGH

A range of single pair Bus cables is available for the LonWorks system allowing convenient wiring via

the Free Topology concept. Due to the popularity of the system for building management applications

in the public sector these cables are now stocked in Low Smoke Halogen Free (LSHF) versions. Duct

grade PE sheaths and SWA options can also be manufactured for quantities as low as 100m.

Available as one and two pair cables, screened and unscreened, they provide the ideal low cost solution

to Bus wiring.

Echelon LonWorks

Part No.

Alt. to

Belden

No. of

Pairs

AWG

Sheath

Material

Weight

kg/km

O/D

mm

Sheath

Colour

1601PUYL 8471 1 16(19) LSF 56 7.0 Grey

1601PUYH 8471 LSHF 1 16(19) LSHF 56 7.0 Grey

1601PUYD 8471 Duct 1 16(19) PE 89 9.4 Black

1601PUYA 8471 SWA 1 16(19) PE 280 13.4 Black

2201PUGH 7701NH 1 22(1) LSHF 14 3.5 White

2201PUGD 7701 Duct 1 22(1) PE 19 5.4 Black

2202PUGH 7702NH 2 22(1) LSHF 27 5.0 White

2202PUGD 7702 Duct 2 22(1) PE 35 6.7 Black

2201POFGH 7703NH 1 22(1) LSHF 23 4.5 White

2201POFGD 7703 Duct 1 22(1) PE 29 6.4 Black

2202POFGH 7704NH 2 22(1) LSHF 36 6.5 White

2202POFGD 7704 Duct 2 22(1) PE 43 8.3 Black

Interbus

The Interbus open ring topology allows integration of different field devices from control level

down to sensor switches over one system. Unlike traditional ring systems, Interbus uses one cable

to route data back and forth to all devices. Each device or unit will amplify the signal before

sending it on to the next station. The data is transmitted over a 3 pair screened cable. For remote

applications a composite data and power cable is available.

2403POBP

Part No.

Alt. to

Belden

Pairs x

mm 2

Sheath

Material

Weight

kg/km

O/D

mm

Sheath

Colour

2403POBP N/A 3P x 0.22 PVC 39 6.7 Violet

2403POBPHF 3102A 3P x 0.22 PUR 41 7.4 Violet

2403/3POBPHF 3119A

3P x 0.22 +

3C x 1.0

PUR 61 9.3 Violet

Low Smoke Halogen Free Duct Grade SWA

CPR-Compliant Options Available

Tel: 01727 840 841

BUS


178

Modbus

2201PODGH

Modbus & ASI Bus Cables

Developed by Modicon, Modbus provides a master/slave communication between intelligent

automation devices. Based on Belden 9841, the Modbus cable has an increased jacket thickness to

ensure a correct termination into the Modbus connectors.

Modbus Plus RS/EIA-485

Part No.

Alt. to

Belden

No. of

Pairs

AWG

Sheath

Material

Weight

kg/km

O/D

mm

Sheath

Colour

2401POHPH+ YM29560 1 24(7) LSHF 63 6.7 Grey

2201PODGH 3105A 1 22(7) LSHF 66 7.2 Black

2201PCODGH 3106A 1.5 22(7) LSHF 73 7.7 Black

2202PODGH 3107A 2 22(7) LSHF 110 9.9 Black

2203PODGH 3108A 3 22(7) LSHF 130 10.6 Black

2204PODGH 3109A 4 22(7) LSHF 150 11.2 Black

Modbus RS232

Part No.

Alt. to

Belden

No. of

Pairs

AWG

Sheath

Material

Weight

kg/km

O/D

mm

Sheath

Colour

2203PIFRL 8777 3 22(7) LSF 70 6.9 Grey

2203PIFRH 8777 LSHF 3 22(7) LSHF 70 6.9 Grey

2203PIFRD 8777 Duct 3 22(7) PE 96 8.6 Black

2203PIFRA 8777 SWA 3 22(7) PE 330 13.2 Black

28001502Y

Modbus Coaxial

Part No.

Alt. to

Belden

No. of

Pairs

AWG

Sheath

Material

Weight

kg/km

O/D

mm

Sheath

Colour

390006Q 3092A N/A 18(1) PVC 49 7.6 Black

390006QH 3092A LSHF N/A 18(1) LSHF 49 7.6 Black

390006QD 3092A Duct N/A 18(1) PE 68 9.4 Black

390006QA 3092A SWA N/A 18(1) PE 228 11.5 Black

ASI Bus

A twin parallel core Bus cable using a profiled flat rubber jacket. Connection is simple using a

puncture based connector to clip over the cable and pierce the conductors. Popular in industrial

and machine applications.

Part No.

No. of

Cores

Size mm 2

Sheath

Material

Weight

kg/km

Voltage

Sheath

Colour

28001502Y 2 1.5 Rubber 58 Data Yellow

28001502B 2 1.5 Rubber 58 24 D.C Black

28001502R 2 1.5 Rubber 58 230 A.C Red

Low Smoke Halogen Free Duct Grade SWA CPR-Compliant Options Available

www.fscables.com | sales@fscables.com


Industrial Ethernet, CC-Link & Pilz

179

Industrial Ethernet, CC-Link & Pilz

C5SHF

Through the use of Lan style cables, Industrial Ethernet provides a stable platform for linking

automation systems and workstations. They are also suitable for interlinking different Bus

protocols such as Profibus and Interbus. The use of finely stranded conductors and PUR sheathing

compounds makes them ideal for frequent flexing and dynamic applications.

Industrial Ethernet

Part No.

No. of

Pairs

AWG

Sheath

Material

Weight

kg/km

O/D

mm

Sheath

Colour

C52SHF 2 24(19) PUR 65 6.1 Green

C5SHF 4 24(19) PUR 82 8.0 Green

C5S26HF 4 26(19) PUR 72 6.3 Green

C6SHF 4 26(19) PUR 79 7.9 Green

C7SHF 4 23(1) PUR 68 8.2 Green

CC-Link

Developed by Mitsubishi, CC-Link allows high speed communication between controllers and field

devices. CC-Link is particularly popular in Asia and is used worldwide for time critical applications

in conjunction with Mitsubishi Automation products. CC-Link is certified by CLPA and ensures

product compatibility.

Part No.

Alt. to

Belden

No. of

Pairs

AWG

Sheath

Material

Weight

kg/km

O/D

mm

Sheath

Colour

2003CODF03 1348A 3 20(7) PVC 186 7.6 Red

2003CODFD00 1348A Duct 3 20(7) PE 212 9.9 Black

2003CODFA00 1348A SWA 3 20(7) PE 276 12.0 Black

2003CODFA03 1348A SWA 3 20(7) PE 276 12.0 Red

2003CODF03

Pilz Safety Bus p ®

Safety Bus p ® is an open Fieldbus system based on well established CAN Bus technology. Safety

Bus p ® modules must be self monitoring, perform intelligent checks and react independently,

therefore remaining ‘safe’. Several versions of Safety Bus p ® cables are available depending on the

application and environmental conditions.

Part No.

No. of

Cores

Size mm 2

Sheath

Material

Weight

kg/km

O/D

mm

Sheath

Colour

28100703 3 0.75 PVC 89 7.5 Yellow

28100703H 3 0.75 LSHF 89 7.5 Yellow

28100702HF 3 0.75 PUR 89 7.5 Yellow

Low Smoke Halogen Free Duct Grade SWA

Tel: 01727 840 841

BUS


ORDER

BY 6PM

AND IF WE

CAN SHIP IT

WE WILL


181

Marine & Offshore

Introduction

The technology used in marine and offshore

applications is advancing at an incredible rate and

the need for cables to link equipment or systems to

enable reliable communications is rapidly increasing.

Until recently the availability of products with the

relevant approvals has often caused problems,

however, FSC are pleased to have built a range of

products tested and approved by DNV-GL and ABS.

The increase in the amount of data transmitted

around a vessel has led to more sophisticated and

higher performance cable being routinely specified.

That’s why we are constantly increasing our stock to

meet your requirements.

Construction focuses on performance in difficult

operating conditions with fire retardant and Low

Smoke Halogen Free (LSHF) materials being central.

MUD resistant sheaths are also an option where

there is a risk of contamination from hydrocarbons

on drilling rigs etc.

Contents

Cat 5E, Cat 6 & Cat 6A 182

Cat 7, Cat 7A & Cat 8.1 183

RG Coaxial 184

RF400 & RF LLF Coaxial 185

Bus Cables 186 & 187

QFCI Fibre Optic 188 - 190

AICI Fibre Optic 191

XT Power & Insturmentation 192 - 195

XAT Power & Instrumentation 196 - 199

XAT-331 Power & Instrumentation 200 - 203

XTS Single Core 204

Reliable delivery is critical to ports around the world,

where tight deadlines are common, to complete

refits, maintenance and repairs. FSC are able to

offer delivery where and when required to meet

your project deadline.

Tel: 01727 840 841

MARINE & OFFSHORE


182

LAN/Structured Wiring

Cat 5E, Cat 6 & Cat 6A LAN Cables

LAN cables for marine applications are often installed in more hostile environments than conventional land-based cables,

that’s why the FSC range of structured wiring has been engineered to perform to the relevant standards even in some of

the most arduous conditions. Vibration, solvents, pollutants, gases and climatic changes can all reduce a cables ability to

carry data at the required rates.

Cat 5E, Cat 6 and Cat 6A are used for traditional data transfer monitoring systems, CCTV and video distribution as well

as Wi-Fi and telephony. Along with a range of approvals for marine applications, the cables’ also feature various levels of

screening.

SM000007

Cat 5E Offshore Marine Approved LAN Cables DNV-GL Approved

TECHNICAL INFORMATION

Impedance:

100 Ohms

Capacitance Unbalanced:

Temperature Rating:

Min. Bend Radius:

1600 pF/km

-40°C to +80°C

10 x OD

Smoke Emission: IEC/BS EN 61034-2

Halogen Emission: IEC/BS EN 60754-1 & 2

Flame Retardant: IEC/BS EN 60332-1,

IEC/BS EN 60332-3-24

Cat.C

IEC/BS EN 60332-3-22

Cat.A

Sheathing Material: IEC 60092-360 (359)

Part No.

AWG

No. of

Pairs

Screen

Sheath

Material

Sheath

Colour

Approval

Weight

kg/km

SM000007 24(7) 4 S/FTP SHF1 Grey DNV-GL, LR 68 7.7

SM000102 24(7) 4 S/FTP SHF1 Grey DNV-GL 68 8.4

O/D

mm

Cat 6 F/UTP Offshore Marine Approved LAN Cables DNV-GL Approved

TECHNICAL INFORMATION

Impedance:

100 Ohms

Capacitance Unbalanced:

Temperature Rating:

Min. Bend Radius:

1600 pF/km

-40°C to +80°C

10 x OD

Smoke Emission: IEC/BS EN 61034-2

Halogen Emission: IEC/BS EN 60754-1 & 2

Flame Retardant: IEC/BS EN 60332-1-2,

IEC/BS EN 60332-3-22

Cat.A

Sheathing Material: IEC 60092-360 (359)

SM000141

Part No.

AWG

No. of

Pairs

Screen

Sheath

Material

Sheath

Colour

Approval

Weight

kg/km

SM000141 23(1) 4 F/UTP SHF1 Grey DNV-GL 60 7.8

O/D

mm

Cat 6A Offshore Marine Approved LAN Cables DNV-GL Approved

TECHNICAL INFORMATION

Impedance:

100 Ohms

Capacitance Unbalanced:

Temperature Rating:

1600 pF/km

-40°C to +80°C

Min. Bend Radius: 10 x OD

Smoke Emission: IEC/BS EN 61034-2

Halogen Emission: IEC/BS EN 60754-1 & 2

Flame Retardant: IEC/BS EN 60332-1-2,

IEC/BS EN 60332-3-22

Cat.A

Sheathing Material: IEC 60092-360 (359)

Part No. Armour AWG

No. of

Pairs

Screen

Sheath

Material

Sheath

Colour

Approval

Weight

kg/km

O/D

mm

SM000086 - 23(7) 4 S/FTP SHF1 Grey DNV-GL 80 8.3

SM000140 GSWB 23(7) 4 S/FTP SHF1 Black DNV-GL 103 11.2

Armoured and MUD resistant sheath versions are also available on request.

www.fscables.com | sales@fscables.com


LAN/Structured Wiring

183

Cat 7, Cat 7A & Cat 8.1 LAN Cables

For large file transfers or higher data rates Cat 7, Cat 7A and Cat 8 all offer greater bandwidth. They also offer high

levels of screening which may be particularly important in electrically noisy environments where physical separation of

cables may not be possible due to routing constraints. With approvals including ABS and DNV-GL options include SHF1

or MUD resistant jackets making them suitable for vessels and rigs alike.

Cat 7 S/FTP Offshore Marine Approved LAN Cables DNV-GL & ABS Approved

TECHNICAL INFORMATION

Impedance:

100 Ohms

Capacitance Unbalanced:

Temperature Rating:

Min. Bend Radius:

1600 pF/km

-40°C to +80°C

10 x OD

Smoke Emission: IEC/BS EN 61034-2

Halogen Emission: IEC/BS EN 60754-1 & 2

Flame Retardant: IEC/BS EN 60332-1,

IEC/BS EN 60332-3-22

Cat.A

IEC BS/EN 60332-3-24

Cat.C

Sheathing Material: IEC 60092-360 (359)

SM000145

Part No.

AWG

No. of

Pairs

Screen

Sheath

Material

Sheath

Colour

Approval

Weight

kg/km

SM000022 23(7) 4 S/FTP SHF1 Grey DNV-GL & ABS 97 8.5

SM000145 23(7) 4 S/FTP SHF1 Grey DNV-GL 97 8.5

SM000028 23(7) 4 S/FTP MUD Black DNV-GL & ABS 120 10.0

O/D

mm

Cat 7A S/FTP Offshore Marine Approved LAN Cables DNV-GL Approved

TECHNICAL INFORMATION

Impedance:

100 Ohms

Capacitance Unbalanced:

Temperature Rating:

Conductor Size:

Min. Bend Radius:

1600 pF/km

Part No. Armour AWG

-40°C to +80°C

23AWG

10 x OD

Smoke Emission: IEC/BS EN 61034-2

Halogen Emission: IEC/BS EN 60754-1 & 2

No. of

Pairs

Screen

Flame Retardant: IEC/BS EN 60332-1,

IEC/BS EN 60332-3-22

Cat.A

Sheathing Material: IEC 60092-360 (359)

Sheath

Material

Sheath

Colour

Approval

Weight

kg/km

SM000143 - 23(1) 4 S/FTP SHF1 Grey DNV-GL 98 8.0

SM000144 - 23(7) 4 S/FTP SHF1 Grey DNV-GL 105 9.0

SM000146 GSWB 23(1) 4 S/FTP SHF1 Black DNV-GL 120 12.2

O/D

mm

SM000146

Cat 8.1 S/FTP Offshore Marine Approved LAN Cables DNV-GL Approved

TECHNICAL INFORMATION

Impedance:

100 Ohms

Capacitance Unbalanced: 1600 pF/km

Temperature Rating:

Min. Bend Radius:

-40°C to +80°C

10 x OD

Smoke Emission: IEC/BS EN 61034-2

Halogen Emission: IEC/BS EN 60754-1 & 2

Flame Retardant: IEC/BS EN 60332-1,

IEC/BS EN 60332-3-22

Cat.A

Sheathing Material: IEC 60092-360 (359)

Part No.

AWG

No. of

Pairs

Screen

Sheath

Material

Sheath

Colour

Approval

Weight

kg/km

SM000142 23(1) 4 S/FTP SHF1 Black DNV-GL 100 8.0

O/D

mm

Armoured and MUD resistant sheath versions are also available on request.

Tel: 01727 840 841

MARINE & OFFSHORE


184

RG Coaxial Cables

RG Coaxial Cables

Coaxial cables have a wide range of applications from radio and antenna mast links, through to computer and data

signalling, monitoring and sensing. For offshore applications or situations when the environment is hostile and the

survival of the cable is vital the FSC range of Marine grade coax cables cover most applications. Sheathed with SHF1 Low

Smoke Halogen Free (LSHF) or MUD resistant compounds to NEK TS 606 and approved to DNV-GL & ABS, these cables

offer extremely good protection against oils and chemicals involved in drilling and oil production.

SM000053

TECHNICAL INFORMATION

Flame Retardant: IEC/BS EN 60332-1-2,

IEC/BS EN 60332-3-22

Cat.A

RG6 Offshore Marine Approved Coax Cables DNV-GL & ABS

Part No.

Stranding

No. x mm Armour Imp.

(Ohms)

SM000038 1 x 0.72 - 75

SM000055 1 x 0.72 GSWB 75

Screen

Foil &

2 x Braid

Foil &

2 x Braid

RG11 Offshore Marine Approved Coax Cables DNV-GL & ABS

Part No.

Stranding

No. x mm Armour Imp.

(Ohms)

SM000039 7 x 0.40 - 75

SM000056 7 x 0.40 GSWB 75

Screen

Foil &

Braid

Foil &

Braid

RG58 Offshore Marine Approved Coax Cables DNV-GL & ABS

Part No.

Stranding

No. x mm Armour Imp.

(Ohms)

SM000015 19 x 0.18 - 50

SM000047 19 x 0.18 - 50

SM000057 19 x 0.18 GSWB 50

Screen

Foil &

Braid

Foil &

Braid

Foil &

Braid

RG59 Offshore Marine Approved Coax Cables DNV-GL & ABS

Part No.

Stranding

No. x mm Armour Imp.

(Ohms)

SM000053 1 x 0.58 - 75

SM000059 1 x 0.58 GSWB 75

SM000069 7 x 0.20 - 75

Screen

Foil &

Braid

Foil &

Braid

Foil &

Braid

RG213 Offshore Marine Approved Coax Cables DNV-GL & ABS

Part No.

Stranding

No. x mm Armour Imp.

(Ohms)

SM000050 7 x 0.75 - 50

SM000061 7 x 0.75 GSWB 50

Screen

Foil &

Braid

Foil &

Braid

RG214 Offshore Marine Approved Coax Cables DNV-GL & ABS

Part No.

Stranding

No. x mm Armour Imp.

(Ohms)

SM000021 7 x 0.75 - 50

SM000060 7 x 0.75 GSWB 50

Smoke Emission: IEC/BS EN 61034-1 & 2

Halogen Emission: IEC/BS EN 60754-1 & 2

3rd Party Approvals:

Screen

Foil &

2 x Braid

Foil &

2 x Braid

Sheath

Material

Sheath

Colour

Weight

kg/km

O/D

mm

SHF1 Black 115 8.5

SHF1 Black 230 11.5

Sheath

Material

Sheath

Colour

Weight

kg/km

O/D

mm

SHF1 Black 150 10.3

SHF1 Black 277 13.5

Sheath

Material

Sheath

Colour

Weight

kg/km

O/D

mm

SHF1 Black 42 5.0

MUD Black 53 7.0

MUD Black 171 11.0

Sheath

Material

Sheath

Colour

Weight

kg/km

O/D

mm

SHF1 Black 53 6.2

SHF1 Black 143 9.4

SHF1 Black 53 6.2

Sheath

Material

Sheath

Colour

Weight

kg/km

O/D

mm

SHF1 Black 167 10.3

SHF1 Black 295 13.5

Sheath

Material

Sheath

Colour

DNV-GL & ABS

Weight

kg/km

O/D

mm

SHF1 Black 206 10.8

SHF1 Black 324 14.8

For more information and technical datasheets, please visit www.fscables.com/marine

www.fscables.com | sales@fscables.com


Coaxial Cables

185

RF400 & Corrugated Coaxial Cables

The NEK range of low-loss corrugated coax cables are ideal for use on offshore antennae offering similar performance

to CommScope®, Andrew® and Heliax® cables with the benefit of DNV-GL approval and a Low Smoke Halogen Free

(LSHF) construction.

To complement the range, DNV-GL approved RF400 ultra low-loss coax cable provides a highly flexible jumper cable

solution for easy termination providing a marine approved alternative to Times Microwave® LMR400 style cables.

RF LLF Hiflex & RF LLF Offshore Marine Approved Corrugated Coax Cables DNV-GL

Part No.

Description

Imp.

(Ohms)

Screen

Sheath

Material

Sheath

Colour

Approval

Weight

kg/km

SM000108 RF LLF 1/2"Hiflex 50 Corrugated Cu SHF1 Black DNV-GL 190 13.7

SM000111 RF LLF 1/2" 50 Corrugated Cu SHF1 Black DNV-GL 250 16.4

SM000112 RF LLF 7/8" Hiflex 50 Corrugated Cu SHF1 Black DNV-GL 430 27.5

SM000114 RF LLF 7/8" 50 Corrugated Cu SHF1 Black DNV-GL 450 28.5

SM000115 RF LLF 1 1/4" 50 Corrugated Cu SHF1 Black DNV-GL 850 39.0

SM000116 RF LLF 1/2" Hiflex 50 Corrugated Cu SHF2 Black DNV-GL 190 13.7

SM000119 RF LLF 1/2" 50 Corrugated Cu SHF2 Black DNV-GL 250 16.4

SM000120 RF LLF 7/8" Hiflex 50 Corrugated Cu SHF2 Black DNV-GL 430 27.5

SM000122 RF LLF 7/8" 50 Corrugated Cu SHF2 Black DNV-GL 450 28.5

SM000123 RF LLF 1/2" Hiflex 50 Corrugated Cu MUD Black DNV-GL 210 14.9

SM000126 RF LLF 1/2" 50 Corrugated Cu MUD Black DNV-GL 270 18.0

SM000127 RF LLF 7/8" Hiflex 50 Corrugated Cu MUD Black DNV-GL 450 29.5

O/D

mm

SM000108

Marine Approved Ultra Low-Loss Coaxial Cables DNV-GL

Part No.

Stranding

No. x mm Description Imp.

(Ohms)

SM000105 7 x 1.0 RF400 UF 50

SM000106 1 x 2.74 RF400 50

Screen

Foil &

Braid

Foil &

Braid

Sheath

Material

Sheath

Colour

Approval

Weight

kg/km

O/D

mm

SHF1 Black DNV-GL 155 10.3

SHF1 Black DNV-GL 127 10.3

For more information and technical datasheets, please visit www.fscables.com/marine

Tel: 01727 840 841

MARINE & OFFSHORE


186

Bus Cables

Profibus and Industrial Bus Cables

The popularity of Bus systems is not limited to land-based installations. The range of Profibus and Profinet cables

for process automation meets IEC 61158 and are designed to enable equipment and devices from a variety of

manufacturers to communicate with one another. Profibus cables with DNV-GL and NEK606 approval cover most ship

and rig based applications.

SM000029

TECHNICAL INFORMATION

Voltage Rating: 100V

Temperature Rating: -40°C to +90°C

Conductor Stranding: Class 5

Bending Radius Static: 10 x OD

Flame Retardant: IEC BS EN 60332-1-2,

IEC/BS EN 60332-3-22

Cat.A

Smoke Emission: IEC/BS EN 61034-1 & 2

Halogen Emission: IEC/BS EN 60754-1 & 2

Profibus DP Offshore Marine Approved Bus Cables DNV-GL & ABS

CONSTRUCTION

Plain copper or tinned copper conductors, foamskin polyethylene insulation, aluminium/polyester tape screen,

overall tinned copper wire braid, Low Smoke Halogen Free (LSHF) sheath - Black.

Part No. AWG mm²

No. of

Pairs

SM000136 22 0.35 1

SM000029 22 0.35 1

SM000151 22 0.35 1

SM000037 22 0.35 1

Screen

Ovrl. Foil

& Braid

Ovrl. Foil

& Braid

Ovrl. Foil

& Braid

Ovrl. Foil

& Braid

Sheath

Material

Sheath

Colour

Approval

Weight

kg/km

O/D

mm

SHF1 Black DNV-GL 85 7.8

SHF2

Black

DNV-GL

& ABS

95 8.6

SHF2 Black DNV-GL 95 8.6

MUD

Black

DNV-GL

& ABS

110 10.0

Profibus PA Offshore Marine Approved Bus Cables DNV-GL

CONSTRUCTION

Plain copper conductors, foamskin polyethylene insulation, overall tinned copper wire braid, LSHF sheath - Black.

Part No.

mm²

No. of

Pairs

SM000137 1.0 1

Part No.

AWG

No. of

Cores

SM000153 22(7) 4

Part No.

AWG

No. of

Cores

SM000152 22(7) 4

Screen

Overall

Braid

Screen

Ovrl. Foil

& Braid

Screen

Ovrl. Foil

& Braid

Sheath

Material

Sheath

Colour

Approval

Weight

kg/km

O/D

mm

SHF1 Black DNV-GL 73 7.9

Industrial Bus RS485 120 Ohm Offshore Marine Approved Cable DNV-GL

CONSTRUCTION

Stranded tinned copper conductors, foamed polyethylene insulation, aluminium/mylar screen, overall tinned

copper wire braid (85%), LSHF SHF1 sheath – Green.

Sheath

Material

Sheath

Colour

Industrial Bus Profinet B Offshore Marine Approved Cable DNV-GL

Approval

Weight

kg/km

O/D

mm

SHF1 Green DNV-GL 58 6.5

CONSTRUCTION

Stranded tinned copper conductors, polyethylene insulation, LSHF bedding, collective aluminium/mylar tape

screen, overall tinned copper wire braid (85%), LSHF SHF1 sheath – Green.

Sheath

Material

Sheath

Colour

For more information and technical datasheets, please visit www.fscables.com/marine

Approval

Weight

kg/km

O/D

mm

SHF1 Green DNV-GL 64 7.3

www.fscables.com | sales@fscables.com


Bus Cables

187

CAN-Bus Cables

CAN-Bus offer many advantages on vessels and rigs, their small diameters and light weight enable easy routing even

in confined spaces. Large amounts of data can be sent between intelligent devices over a single cable. CAN-Bus which

stands for Control Area Network is ideal for sensing, measuring and control of a wide range of aspects of a ship or rig

operating to the requirements of ISO 11898-2. Manufactured in a variety of formats including SHF1, SHF2, armoured or

MUD resistant.

CONSTRUCTION

Plain copper or tinned copper stranded conductors,

polyethylene insulation, collective aluminium/mylar or

aluminium/polyester & aluminium tape screen, overall

tinned copper wire braid, Low Smoke Halogen Free

(LSHF) sheath - Black.

TECHNICAL INFORMATION

Voltage Rating: 100V

Temperature Rating: -40°C to +90°C

Conductor Stranding: Class 5

Bending Radius Static: 10 x OD

Flame Retardant: IEC BS EN 60332-1-2,

IEC/BS EN 60332-3-22

Cat.A

Smoke Emission: IEC/BS EN 61034-1 & 2

Halogen Emission: IEC/BS EN 60754-1 & 2

SM000138

CAN Bus Offshore Marine Approved Bus Cables DNV-GL & ABS

Part No.

No. of

Pairs

mm²

Screen

Sheath

Material

Sheath

Colour

Approval

Weight

kg/km

O/D

mm

SM000138* 1 0.75 Ovrl. Foil & Braid SHF1 Black DNV-GL 120 11.2

SM000040* 1 0.75 Ovrl. Foil & Braid SHF2 Black

DNV-GL

& ABS

200 11.1

SM000150 2 0.75 Ovrl. Foil & Braid SHF2 Black DNV-GL 143 10.5

SM000041* 1 0.75 Ovrl. Foil & Braid MUD Black DNV-GL 260 14.0

SM000139 2 0.75 Ovrl. Foil & Braid SHF1 Black DNV-GL 110 10.5

SM000042 2 0.75 Ovrl. Foil & Braid SHF2 Black

DNV-GL

& ABS

170 10.5

SM000149* 1 0.75 Ovrl. Foil & Braid SHF2 Black DNV-GL 203 11.2

SM000042

SM000043 2 0.75 Ovrl. Foil & Braid MUD Black DNV-GL 170 12.7

*Includes an additional Green/Yellow tinned copper 0.75mm² earth wire.

For more information and technical datasheets, please visit www.fscables.com/marine

Tel: 01727 840 841

MARINE & OFFSHORE


188

QFCI Fibre

QFCI Multimode 62.5/125µm Fibre Optic Cable Armoured

QFCI fibre optic cables to NEK 606 provides the perfect fibre optic cable solution for offshore emergency communication

links requiring fire resistant cables. QFCI fibre cables meet the circuit integrity requirements of IEC 60331-25 and are

designed to continue operating in a fire for 3 hours at 750°C, ensuring safety systems keep functioning.

The loose tube construction and steel braid armour keeps QFCI flexible for installation on rigs and ships whilst protecting

the optical fibre cores. The cable is sheathed in a Low Smoke Halogen Free (LSHF) compound in accordance with IEC

60092-359 providing weather, UV & oil resistance making the cable ideal for indoor and outdoor use on offshore

installations and designed for use on yachts, boats and larger commercial ships.

The QFCI fibre optic cable range are flame retardant and 3rd party approved by DNV-GL & ABS ensuring quality and

safety for a hazardous industry within the shipping and offshore sector.

FOM112QFCI1

CONSTRUCTION

Multi gel filled tubes each tube mica glass taped, tubes

laid up around a central steel wire and all surrounded

by waterblocked E-Glass fibre elements, SHF1 LSHF

bedding, galvanised steel wire braid, SHF1 LSHF UV

resistant sheath – Black.

TECHNICAL INFORMATION

Temperature Rating: -40°C to +70°C

Bending Radius: Static: 15 x O/D

Flexible: 20 x O/D

Flame Retardant: IEC/BS EN 60332-3-22

Cat.A

Smoke Emission: IEC/BS EN 61034-1 & 2

EN 50268-2

Halogen Emission: IEC/BS EN 60754-1 & 2

Fire Resistant: IEC 60331-25

Sheathing Material:

Weather Resistant:

IEC 60092-360 (359) NEK

TS 606 F101 (F1) NEK 606

IEC 60794-1-22-F1

Ozone Resistant: IEC 60811-2-1

Oil, Fuel and

Hydrocarbons Resistant: IEC 60811-404 IRM 903

UV Resistant: ASTM G 154

3rd Party Approvals:

DNV-GL, ABS

QFCI OM1 Multimode 62.5/125µm Loose Tube Fibre Optic Armoured

Part No.

Armour

No. of

Cores

Sheath

Material

Sheath

Colour

Weight

kg/km

O/D mm

FOM104QFCI1 GSWB 4 SHF1 Black 260 13.5

FOM104QFCI2 GSWB 4 SHF2 Black 350 16.5

FOM104QFCIM GSWB 4 MUD Black 350 16.5

FOM106QFCI1 GSWB 6 SHF1 Black 260 13.5

FOM106QFCI2 GSWB 6 SHF2 Black 350 16.5

FOM106QFCIM GSWB 6 MUD Black 350 16.5

FOM108QFCI1 GSWB 8 SHF1 Black 260 13.5

FOM108QFCI2 GSWB 8 SHF2 Black 350 16.5

FOM108QFCIM GSWB 8 MUD Black 350 16.5

FOM112QFCI1 GSWB 12 SHF1 Black 260 13.5

FOM112QFCI2 GSWB 12 SHF2 Black 350 16.5

FOM112QFCIM GSWB 12 MUD Black 350 16.5

FOM124QFCI1 GSWB 24 SHF1 Black 260 13.5

FOM124QFCI2 GSWB 24 SHF2 Black 350 16.5

FOM124QFCIM GSWB 24 MUD Black 350 16.5

QFAI non-metallic armoured marine approved fibre optic cables are also offered - www.fscables.com/qfai

Larger fibre counts and copper or bronze armour versions are also available.

For more information and technical datasheets, please visit www.fscables.com/marine-fibre

www.fscables.com | sales@fscables.com


QFCI Fibre

189

QFCI Multimode 50/125µm Fibre Optic Cable Armoured

QFCI OM2 Multimode 50/125µm Loose Tube Fibre Optic Armoured

Part No.

Armour

No. of

Cores

Sheath

Material

Sheath

Colour

Weight

kg/km

O/D

mm

FOM204QFCI1 GSWB 4 SHF1 Black 260 13.5

FOM204QFCI2 GSWB 4 SHF2 Black 350 16.5

FOM204QFCIM GSWB 4 MUD Black 350 16.5

FOM206QFCI1 GSWB 6 SHF1 Black 260 13.5

FOM206QFCI2 GSWB 6 SHF2 Black 350 16.5

FOM206QFCIM GSWB 6 MUD Black 350 16.5

FOM208QFCI1 GSWB 8 SHF1 Black 260 13.5

FOM208QFCI2 GSWB 8 SHF2 Black 350 16.5

FOM208QFCIM GSWB 8 MUD Black 350 16.5

FOM212QFCI1 GSWB 12 SHF1 Black 260 13.5

FOM212QFCI2 GSWB 12 SHF2 Black 350 16.5

FOM212QFCIM GSWB 12 MUD Black 350 16.5

FOM224QFCI1 GSWB 24 SHF1 Black 260 13.5

FOM224QFCI2 GSWB 24 SHF2 Black 350 16.5

FOM224QFCIM GSWB 24 MUD Black 350 16.5

QFCI OM3 Multimode 50/125µm Loose Tube Fibre Optic Armoured

Part No.

Armour

No. of

Cores

Sheath

Material

Sheath

Colour

Weight

kg/km

O/D

mm

FOM304QFCI1 GSWB 4 SHF1 Black 260 13.5

FOM304QFCI2 GSWB 4 SHF2 Black 350 16.5

FOM304QFCIM GSWB 4 MUD Black 350 16.5

FOM306QFCI1 GSWB 6 SHF1 Black 260 13.5

FOM306QFCI2 GSWB 6 SHF2 Black 350 16.5

FOM306QFCIM GSWB 6 MUD Black 350 16.5

FOM308QFCI1 GSWB 8 SHF1 Black 260 13.5

FOM308QFCI2 GSWB 8 SHF2 Black 350 16.5

FOM308QFCIM GSWB 8 MUD Black 350 16.5

FOM312QFCI1 GSWB 12 SHF1 Black 260 13.5

FOM312QFCI2 GSWB 12 SHF2 Black 350 16.5

FOM312QFCIM GSWB 12 MUD Black 350 16.5

FOM324QFCI1 GSWB 24 SHF1 Black 260 13.5

FOM324QFCI2 GSWB 24 SHF2 Black 350 16.5

FOM324QFCIM GSWB 24 MUD Black 350 16.5

QFCI OM4 Multimode 50/125µm Loose Tube Fibre Optic Armoured

Part No.

Armour

No. of

Cores

Sheath

Material

Sheath

Colour

Weight

kg/km

O/D

mm

FOM404QFCI1 GSWB 4 SHF1 Black 260 13.5

FOM404QFCI2 GSWB 4 SHF2 Black 350 16.5

FOM404QFCIM GSWB 4 MUD Black 350 16.5

FOM406QFCI1 GSWB 6 SHF1 Black 260 13.5

FOM406QFCI2 GSWB 6 SHF2 Black 350 16.5

FOM406QFCIM GSWB 6 MUD Black 350 16.5

FOM408QFCI1 GSWB 8 SHF1 Black 260 13.5

FOM408QFCI2 GSWB 8 SHF2 Black 350 16.5

FOM408QFCIM GSWB 8 MUD Black 350 16.5

FOM412QFCI1 GSWB 12 SHF1 Black 260 13.5

FOM412QFCI2 GSWB 12 SHF2 Black 350 16.5

FOM412QFCIM GSWB 12 MUD Black 350 16.5

FOM424QFCI1 GSWB 24 SHF1 Black 260 13.5

FOM424QFCI2 GSWB 24 SHF2 Black 350 16.5

FOM424QFCIM GSWB 24 MUD Black 350 16.5

FOM424QFCI1M

The unarmoured version to the AIAI specification is also available. The non-conductive design is ideal for applications

where metallic elements cannot be used and conductive paths are forbidden.

Please ask for details or visit www.fscables.com/marine-fibre

Tel: 01727 840 841

MARINE & OFFSHORE


190

QFCI Fibre

QFCI Singlemode 9/125µm Fibre Optic Cable Armoured DNV-GL & ABS

QFCI fibre optic cables to NEK 606 provides the perfect fibre optic cable solution for offshore emergency communication

links requiring fire resistant cables. QFCI fibre cables meet the circuit integrity requirements of IEC 60331-25 and are

designed to continue operating in a fire for 3 hours at 750°C, ensuring safety systems keep functioning.

The loose tube construction and steel braid armour keeps QFCI flexible for installation on rigs and ships whilst protecting

the optical fibre cores. The cable is sheathed in a Low Smoke Halogen Free (LSHF) compound in accordance with IEC

60092-359 providing weather, UV & oil resistance making the cable ideal for indoor and outdoor use on offshore

installations and designed for use on yachts, boats and larger commercial ships.

The QFCI fibre optic cable range are flame retardant and 3rd party approved by DNV-GL & ABS ensuring quality and

safety for a hazardous industry within the shipping and offshore sector.

FOS204QFCIM

CONSTRUCTION

Multi gel filled tubes each tube mica glass taped, tubes

laid up around a central steel wire and all surrounded

by waterblocked E-Glass fibre elements, SHF1 LSHF

bedding, galvanised steel wire braid, SHF1 LSHF UV

resistant sheath – Black.

TECHNICAL INFORMATION

Temperature Rating: -40°C to +70°C

Bending Radius: Static: 15 x O/D

Flexible: 20 x O/D

Flame Retardant: IEC/BS EN 60332-3-22

Cat.A

Smoke Emission: IEC/BS EN 61034-1 & 2

EN 50268-2

Halogen Emission: IEC/BS EN 60754-1 & 2

Fire Resistant: IEC 60331-25

Sheathing Material:

Weather Resistant:

IEC 60092-360 (359) NEK

TS 606 F101 (F1) NEK 606

IEC 60794-1-22-F1

Ozone Resistant: IEC 60811-2-1

Oil, Fuel and

Hydrocarbons Resistant: IEC 60811-404 IRM 903

UV Resistant: ASTM G 154

3rd Party Approvals:

DNV-GL, ABS

QFCI OS2 Singlemode 9/125µm Loose Tube Fibre Optic Armoured

Part No.

Armour

No. of

Cores

Sheath

Material

Sheath

Colour

Weight

kg/km

O/D mm

FOS204QFCI1 GSWB 4 SHF1 Black 260 13.5

FOS204QFCI2 GSWB 4 SHF2 Black 350 16.5

FOS204QFCIM GSWB 4 MUD Black 350 16.5

FOS206QFCI1 GSWB 6 SHF1 Black 260 13.5

FOS206QFCI2 GSWB 6 SHF2 Black 350 16.5

FOS206QFCIM GSWB 6 MUD Black 350 16.5

FOS208QFCI1 GSWB 8 SHF1 Black 260 13.5

FOS208QFCI2 GSWB 8 SHF2 Black 350 16.5

FOS208QFCIM GSWB 8 MUD Black 350 16.5

FOS212QFCI1 GSWB 12 SHF1 Black 260 13.5

FOS212QFCI2 GSWB 12 SHF2 Black 350 16.5

FOS212QFCIM GSWB 12 MUD Black 350 16.5

FOS224QFCI1 GSWB 24 SHF1 Black 260 13.5

FOS224QFCI2 GSWB 24 SHF2 Black 350 16.5

FOS224QFCIM GSWB 24 MUD Black 350 16.5

QFAI marine approved fibre optic cables are also offered - www.fscables.com/qfai

Larger fibre counts and copper or bronze armour versions are also available.

For more information and technical datasheets, please visit www.fscables.com/marine-fibre

www.fscables.com | sales@fscables.com


AICI Fibre

191

AICI Multimode & Singlemode Fibre DNV-GL & ABS Approved

AICI fibre optic cable is armoured with a flexible steel braid for easy installation in restricted areas on rigs and ships.

Designed specifically for use offshore, AICI cables are tight buffered and provide fast and easy termination without

splicing. The AICI range of cables use marine grade sheathing compounds in accordance with IEC 60092-359 enabling

AICI to be used inside and outside reducing the need to change cable types. Designed for use on yachts, boats and

larger commercial ships as well as rigs.

The AICI range of fibre optic cables is flame retardant to IEC 60332-3-22 Category A and 3rd party approved by DNV-GL

& ABS ensuring quality and safety for a hazardous industry within the shipping and offshore sector.

CONSTRUCTION

Tight buffered fibres surrounded by waterblocked E-Glass fibre elements, SHF1 Low Smoke Halogen Free (LSHF)

bedding, galvanised steel wire braid, SHF1 LSHF UV resistant sheath - Black.

TECHNICAL INFORMATION

Temperature Rating: -40°C to +70°C

Bending Radius: Static: 10 x O/D

Flexible: 15 x O/D

Flame Retardant: IEC/BS EN 60332-3-22

Cat.A

Smoke Emission: IEC/BS EN 61034-1 & 2

EN 50268-2

AICI OM1 Multimode 62.5/125µm Loose Tube Fibre Optic Armoured

Part No.

Armour

No. of

Cores

Sheath

Material

Sheath

Colour

Weight

kg/km

O/D

mm

FOM104AICI1 GSWB 4 SHF1 Black 105 8.5

FOM108AICI1 GSWB 8 SHF1 Black 125 9.4

FOM112AICI1 GSWB 12 SHF1 Black 145 10.3

FOM124AICI1 GSWB 24 SHF1 Black 185 12.1

AICI OM2 Multimode 50/125µm Loose Tube Fibre Optic Armoured

Part No.

Armour

No. of

Cores

Sheath

Material

Sheath

Colour

Weight

kg/km

O/D

mm

FOM204AICI1 GSWB 4 SHF1 Black 105 8.5

FOM208AICI1 GSWB 8 SHF1 Black 125 9.4

FOM212AICI1 GSWB 12 SHF1 Black 145 10.3

FOM224AICI1 GSWB 24 SHF1 Black 185 12.1

AICI OM3 Multimode 50/125µm Loose Tube Fibre Optic Armoured

Part No.

Armour

No. of

Cores

Sheath

Material

Sheath

Colour

Weight

kg/km

O/D

mm

FOM304AICI1 GSWB 4 SHF1 Black 105 8.5

FOM308AICI1 GSWB 8 SHF1 Black 125 9.4

FOM312AICI1 GSWB 12 SHF1 Black 145 10.3

FOM324AICI1 GSWB 24 SHF1 Black 185 12.1

AICI OM4 Multimode 50/125µm Loose Tube Fibre Optic Armoured

Part No.

Armour

No. of

Cores

Sheath

Material

Sheath

Colour

Weight

kg/km

O/D

mm

FOM404AICI1 GSWB 4 SHF1 Black 105 8.5

FOM408AICI1 GSWB 8 SHF1 Black 125 9.4

FOM412AICI1 GSWB 12 SHF1 Black 145 10.3

FOM424AICI1 GSWB 24 SHF1 Black 185 12.1

AICI OS2 Singlemode 9/125µm Loose Tube Fibre Optic Armoured

Part No.

Armour

No. of

Cores

Halogen Emission: IEC/BS EN 60754-1 & 2

Weather Resistant:

Sheath

Material

Sheath

Colour

IEC 60794-1-22-F1

Ozone Resistant: IEC 60811-2-1

Oil, Fuel and

Hydrocarbons Resistant: IEC 60811-3-1

UV Resistant: ASTM G 154

3rd Party Approvals:

DNV-GL, ABS

Weight

kg/km

O/D

mm

FOS204AICI1 GSWB 4 SHF1 Black 105 8.5

FOS208AICI1 GSWB 8 SHF1 Black 125 9.4

FOS212AICI1 GSWB 12 SHF1 Black 145 10.3

FOS224AICI1 GSWB 24 SHF1 Black 185 12.1

FOM112AICI1

AIAI marine approved fibre optic cables are also offered - www.fscables.com/aiai

Tel: 01727 840 841

MARINE & OFFSHORE


192

XT Unarmoured Power

XT Unarmoured Power Cable

XT unarmoured power cables offer a light weight method of wiring within marine and off-shore applications where there

is minimal risk of mechanical damage. The compact sizes allow routing in restricted areas and the LSHF insulation and

SHF1 sheath increase safety in the event of a fire. Manufactured in accordance with European Standard IEC 60092 series

This cable can be used as an alternative to Nexans MPRXCX, Finnish type LKSM-HF, Prysmian HFX-A and UNIKA SH-PC-U.

XT002512

CONSTRUCTION

Plain copper or tinned copper conductors, XLPE

insulation, bedding or filler tape, SHF1 Low Smoke

Halogen Free (LSHF) sheath - Black.

CORE IDENTIFICATION

Generally colour coded up to 5 core and numbered

cores above 5 core. Cables including a Green/

Yellow earth core are available on request.

TECHNICAL INFORMATION

Voltage Rating: 0.6/1kV

Temperature Rating:

-40°C to +85°C or +90°C

Conductor Stranding: IEC 60228 class 2 or class 5,

plain copper or tinned copper

Bending Radius Static: 6 x overall diameter

Flame Retardant: IEC/BS EN 60332-1-2,

IEC/BS EN 60332-3-22 Cat A

Smoke Emission: IEC/BS EN 61034-1 & 2

Halogen Emission: IEC/BS EN 60754-1 & 2

Manufactured To: IEC 60092 series

3rd Party Approvals: Lloyds, DNV-GL, ABS, BV, Rina

Part No.

No. of Cores

Size

mm²

Weight

kg/km

O/D

mm

XT001502 2 1.5 81 8.1

XT001503 3 1.5 108 8.7

XT001504 4 1.5 131 9.5

XT001505 5 1.5 156 10.4

XT001507 7 1.5 206 11.5

XT001512 12 1.5 335 15.1

XT001519 19 1.5 495 17.9

XT001524 24 1.5 625 21.1

XT001527 27 1.5 700 22.5

XT001537 37 1.5 911 24.3

XT002502 2 2.5 111 9.1

XT002503 3 2.5 144 9.6

XT002504 4 2.5 179 10.5

XT002505 5 2.5 221 11.7

XT002507 7 2.5 287 12.7

XT002512 12 2.5 478 17.0

XT002519 19 2.5 718 20.1

XT004002 2 4.0 150 10.3

XT004003 3 4.0 200 10.9

XT004004 4 4.0 257 12.1

XT004005 5 4.0 311 13.3

XT006001 1 6.0 100 6.5

XT006002 2 6.0 203 11.5

XT006003 3 6.0 274 12.2

XT006004 4 6.0 346 13.3

XT006005 5 6.0 431 14.8

XT010001 1 10 145 7.5

XT010003 3 10 412 14.5

XT010004 4 10 529 16.0

XT010005 5 10 652 17.7

www.fscables.com | sales@fscables.com


XT Unarmoured Power

193

XT Unarmoured Power Cable

Part No.

No. of Cores

Size

mm²

Weight

kg/km

O/D

mm

XT016001 1 16 215 8.8

XT016003 3 16 620 17.1

XT016004 4 16 796 18.8

XT016005 5 16 988 20.9

XT025001 1 25 327 10.5

XT025003 3 25 959 20.9

XT025004 4 25 1249 23.3

XT035001 1 35 448 12.0

XT035003 3 35 1311 23.9

XT035004 4 35 1718 26.6

XT050001 1 50 594 13.6

XT050003 3 50 1778 27.8

XT050004 4 50 2331 30.9

XT070001 1 70 819 15.6

XT070003 3 70 2448 31.8

XT070004 4 70 3265 35.6

XT095001 1 95 1095 18.3

XT095003 3 95 3319 37.6

XT120001 1 120 1370 20.6

XT120003 3 120 3456 42.5

XT150001 1 150 1703 23.3

XT150003 3 150 5163 48.3

XT185001 1 185 2039 24.4

XT240001 1 240 2567 27.6

XT300001 1 300 3143 30.8

XT016004

The IEC 60092 shipwiring standard allows for many variations in the cable construction including different

conductor stranding, the use of tinned or plain copper conductors, extruded inner sheaths or binder tapes and

optional core identification methods.

This can result in a change of weight, diameter, look and feel of the cable between different manufacturers. If

you need to size for glands or have a specific construction preference please specify at the time of enquiry.

Tel: 01727 840 841

MARINE & OFFSHORE


194

XT Screened Instrumentation

XT Unarmoured Instrumentation Cable Collective Screen

XT Instrumentation marine cables were originally designed as a lightweight ship wiring cable. They have become popular

throughout the petrochemical and process control industries due to their low smoke, low gas generation and increased

flame retardant properties. XT-C offers collective foil screening.

XT-C can be used as an alternative to Nexans TX (C), Finnish type RFA-HF, Prysmian HFX-OSU and UNIKA SH-CI-C-U.

XTC0501P

CONSTRUCTION

Plain copper or tinned copper conductors, XLPE

insulation, aluminium/polyester foil screen and drain

wire, SHF1 Low Smoke Halogen Free (LSHF) sheath

(LSHF) – Grey.

CORE IDENTIFICATION

Pairs are colour coded or number coded. This can

vary depending on the manufacturer, please specify

if you have a preference.

TECHNICAL INFORMATION

Voltage Rating: 150/250V (300V)

Temperature Rating:

-40°C to +85°C or +90°C

Conductor Stranding: IEC 60228 class 2 or class 5,

plain copper or tinned copper

Bending Radius Static: 6 x overall diameter

Flame Retardant: IEC/BS EN 60332-1-2,

IEC/BS EN 60332-3-22 Cat A

Smoke Emission: IEC/BS EN 61034-1 & 2

Halogen Emission: IEC/BS EN 60754-1 & 2

Manufactured To: IEC 60092 series

3rd Party Approvals: Lloyds, DNV-GL, ABS, BV, Rina

Part No.

No. of

Pairs

Size

mm²

Weight

kg/km

O/D

mm

XTC0501P 1 0.5 40 6.5

XTC0502P 2 0.5 74 7.9

XTC0504P 4 0.5 107 9.3

XTC0507P 7 0.5 158 11.0

XTC0510P 10 0.5 216 12.7

XTC0514P 14 0.5 284 15.4

XTC0519P 19 0.5 378 17.3

XTC0524P 24 0.5 472 20.4

XTC0537P 37 0.5 678 23.4

XTC0702P 2 0.75 103 9.4

XTC0704P 4 0.75 154 10.8

XTC0707P 7 0.75 249 13.1

XTC0710P 10 0.75 330 17.1

XTC0714P 14 0.75 430 18.5

XTC0719P 19 0.75 548 20.8

XTC0724P 24 0.75 687 24.5

The IEC 60092 shipwiring standard allows for many variations in the cable construction including different

conductor stranding, the use of tinned or plain copper conductors, extruded inner sheaths or binder tapes and

optional core identification methods.

This can result in a change of weight, diameter, look and feel of the cable between different manufacturers. If

you need to size for glands or have a specific construction preference please specify at the time of enquiry.

www.fscables.com | sales@fscables.com


XT Screened Instrumentation

195

XT Unarmoured Instrumentation Cable Individual Screen

XT Instrumentation marine cables were originally designed as a lightweight ship wiring cable. They have become popular

throughout the petrochemical and process control industries due to their low smoke, low gas generation and increased

flame retardant properties. XT-I includes an additional foil screen around each pair to prevent crosstalk.

XT-I can be used as an alternative to Finnish type RFA-HF (i), Prysmian HFX-ISOSU and UNIKA SH-CI-IC-U.

CONSTRUCTION

Plain copper or tinned copper conductors, XLPE

insulation, each pair aluminium/polyester foil

screened with a drain wire, pairs laid up, SHF1 Low

Smoke Halogen Free (LSHF) sheath – Grey.

CORE IDENTIFICATION

Pairs are colour coded or number coded. This can

vary depending on the manufacturer, please specify

if you have a preference.

TECHNICAL INFORMATION

Voltage Rating: 150/250V (300V)

Temperature Rating:

-40°C to +85°C or +90°C

Conductor Stranding: IEC 60228 class 2 or class 5,

plain copper or tinned copper

Bending Radius Static: 6 x overall diameter

Flame Retardant: IEC/BS EN 60332-1-2,

IEC/BS EN 60332-3-22 Cat A

Smoke Emission: IEC/BS EN 61034-1 & 2

Halogen Emission: IEC/BS EN 60754-1 & 2

Manufactured To: IEC 60092 series

3rd Party Approvals: Lloyds, DNV-GL, ABS, BV, Rina

XTI0707P

Part No.

No. of

Pairs

Size

mm²

Weight

kg/km

O/D

mm

XTI0702P 2 0.75 122 10.0

XTI0704P 4 0.75 198 11.8

XTI0707P 7 0.75 303 14.2

XTI0710P 10 0.75 432 18.3

XTI0714P 14 0.75 564 20.0

XTI0719P 19 0.75 742 22.5

XTI0724P 24 0.75 950 26.5

The IEC 60092 shipwiring standard allows for many variations in the cable construction including different

conductor stranding, the use of tinned or plain copper conductors, extruded inner sheaths or binder tapes and

optional core identification methods.

This can result in a change of weight, diameter, look and feel of the cable between different manufacturers. If

you need to size for glands or have a specific construction preference please specify at the time of enquiry.

Tel: 01727 840 841

MARINE & OFFSHORE


196

XAT Armoured Power

XAT Armoured Power Cable

XAT power cables provide lightweight wiring in marine applications where mechanical protection is required and

personnel safety in the event of a fire is important. Manufactured in accordance with European standard IEC 60092

series.

The heavy copper wire braid offers good mechanical protection whilst remaining flexible enough to enable routing

through confined spaces. The copper braid armour will also act as a screen to reduce electromagnetic radiation.

Can be used as an alternative to Nexans MPRXCX, Finnish type LKSM-HF, Prysmian HFX-A and UNIKA SH-PC-A.

XAT001504

CONSTRUCTION

Plain copper or tinned copper conductors, XLPE

insulation, bedding, copper wire braid armour or

tinned copper wire braid, SHF1 Low Smoke Halogen

Free (LSHF) sheath - Black.

CORE IDENTIFICATION

Generally colour coded up to 5 core and numbered

cores above 5 core. Cables including a Green/

Yellow earth core are available on request.

Cables ending with E include an Earth core.

TECHNICAL INFORMATION

Voltage Rating: 0.6/1kV

Temperature Rating:

-40°C to +85°C or +90°C

Conductor Stranding: IEC 60228 class 2 or class 5,

plain copper or tinned copper

Bending Radius Static: 6 x overall diameter

Flame Retardant: IEC/BS EN 60332-1-2,

IEC/BS EN 60332-3-22 Cat A

Smoke Emission: IEC/BS EN 61034-1 & 2

Halogen Emission: IEC/BS EN 60754-1 & 2

Manufactured To: IEC 60092 series

3rd Party Approvals: Lloyds, DNV-GL, ABS, BV, Rina

Part No.

No. of Cores

Size

mm²

Weight

kg/km

O/D

mm

XAT001502 2 1.5 96 9.1

XAT001503 3 1.5 120 9.5

XAT001504 4 1.5 143 10.3

XAT001505 5 1.5 175 11.4

XAT001507 7 1.5 221 12.3

XAT001512 12 1.5 378 16.3

XAT001519 19 1.5 545 19.3

XAT001524 24 1.5 684 22.5

XAT001527 27 1.5 855 24.0

XAT001537 37 1.5 979 25.7

XAT002502 2 2.5 123 9.9

XAT002503 3 2.5 156 10.4

XAT002504 4 2.5 198 11.5

XAT002505 5 2.5 236 12.5

XAT002507 7 2.5 323 14.1

XAT002512 12 2.5 517 18.2

XAT002519 19 2.5 763 21.3

XAT004002 2 4.0 169 11.3

XAT004003 3 4.0 220 11.9

XAT004003E 2+E 4.0 220 11.9

XAT004004 4 4.0 273 12.9

XAT004005 5 4.0 349 14.7

XAT006001 1 6.0 112 7.4

XAT006002 2 6.0 218 12.3

XAT006003 3 6.0 290 13.0

XAT006003E 2+E 6.0 290 13.0

The IEC 60092 shipwiring standard allows for many variations in the cable construction including different

conductor stranding, the use of tinned or plain copper conductors, extruded inner sheaths or binder tapes and

optional core identification methods.

This can result in a change of weight, diameter, look and feel of the cable between different manufacturers. If

you need to size for glands or have a specific construction preference please specify at the time of enquiry.

www.fscables.com | sales@fscables.com


XAT Armoured Power

197

XAT Armoured Power Cable

Part No.

No. of Cores

Size

mm²

Weight

kg/km

O/D

mm

XAT006004 4 6.0 384 14.7

XAT006005 5 6.0 465 16.0

XAT010001 1 10 163 8.6

XAT010002 2 10 332 14.9

XAT010003 3 10 445 15.7

XAT010004 4 10 573 17.4

XAT010005 5 10 692 18.9

XAT016001 1 16 231 9.7

XAT016002 2 16 481 17.3

XAT016003 3 16 658 18.3

XAT016003E 2+E 16 658 18.3

XAT016004 4 16 848 20.2

XAT016005 5 16 1035 22.3

XAT025001 1 25 352 11.6

XAT025002 2 25 727 20.9

XAT025003 3 25 1018 22.3

XAT025004 4 25 1314 24.7

XAT035001 1 35 469 12.9

XAT035003 3 35 1377 25.3

XAT035004 4 35 1792 28.0

XAT050001 1 50 640 15.1

XAT050003 3 50 1841 29.0

XAT050004 4 50 2400 32.1

XAT070001 1 70 872 17.1

XAT070003 3 70 2536 33.2

XAT070004 4 70 3355 37.2

XAT095001 1 95 1157 19.8

XAT095003 3 95 3433 39.4

XAT120001 1 120 1427 22.1

XAT120003 3 120 4270 44.3

XAT150001 1 150 1765 23.5

XAT150003 3 150 5300 50.1

XAT185001 1 185 2101 25.9

XAT240001 1 240 2629 28.9

XAT300001 1 300 3205 32.1

XAT016004

The IEC 60092 shipwiring standard allows for many variations in the cable construction including different

conductor stranding, the use of tinned or plain copper conductors, extruded inner sheaths or binder tapes and

optional core identification methods.

This can result in a change of weight, diameter, look and feel of the cable between different manufacturers. If

you need to size for glands or have a specific construction preference please specify at the time of enquiry.

Tel: 01727 840 841

MARINE & OFFSHORE


198

XAT Armoured Instrumentation

XAT-U Armoured Instrumentation Cable

XAT-U armoured instrumentation marine cables are manufactured in accordance with IEC 60092. Originally designed

for ship wiring, they have become popular throughout the petrochemical and process control industries due to their

low smoke, low gas generation and increased flame retardant properties. XAT-U offers a combined braid screen copper

armour to provide mechanical protection and reduce levels of electromagnetic interference (EMI).

Can be used as an alternative to Finnish type RFE-HF and UNIKA SH-CI-U-A.

XATU1519P

CONSTRUCTION

Plain copper or tinned copper conductors, XLPE

insulation, pairs laid up, bedding filler tape, copper

wire braid screen or tinned copper wire braid

armour, SHF1 Low Smoke Halogen Free (LSHF)

sheath – Grey, Blue or Black.

CORE IDENTIFICATION

Pairs and cores are colour coded or number coded.

This can vary depending on the manufacturer,

please specify if you have a preference.

TECHNICAL INFORMATION

Voltage Rating: 150/250V (300V)

Temperature Rating:

-40°C to +85°C or +90°C

Conductor Stranding: IEC 60228 class 2 or class 5,

plain copper or tinned copper

Bending Radius Static: 6 x overall diameter

Flame Retardant: IEC/BS EN 60332-1-2,

IEC/BS EN 60332-3-22 Cat A

Smoke Emission: IEC/BS EN 61034-1 & 2

Halogen Emission: IEC/BS EN 60754-1 & 2

Manufactured To:

3rd Party Approvals:

IEC 60092 series

Lloyds, DNV-GL, ABS, BV, Rina

Part No. No. of Pairs Size mm² Weight kg/km O/D mm

XATU0701P 1 0.75 90 7.5

XATU0702P 2 0.75 150 11.0

XATU0704P 4 0.75 205 12.5

XATU0707P 7 0.75 290 15.0

XATU0708P 8 0.75 350 16.0

XATU0710P 10 0.75 425 18.0

XATU0712P 12 0.75 475 19.0

XATU0714P 14 0.75 530 20.0

XATU0719P 19 0.75 680 23.0

XATU0724P 24 0.75 820 25.5

XATU1501P 1 1.5 140 10.0

XATU1502P 2 1.5 235 14.5

XATU1504P 4 1.5 280 17.0

XATU1507P 7 1.5 555 20.0

XATU1508P 8 1.5 635 21.5

XATU1510P 10 1.5 770 24.5

XATU1512P 12 1.5 865 26.0

XATU1514P 14 1.5 975 27.5

XATU1519P 19 1.5 1250 31.5

Part No. No. of Cores Size mm² Weight kg/km O/D mm

XATU0502 2 0.5 71 6.4

XATU0503 3 0.5 82 6.7

XATU0504 4 0.5 96 7.2

XATU0507 7 0.5 130 8.2

XATU0510 10 0.5 170 10.1

XATU0514 14 0.5 206 10.9

XATU0519 19 0.5 258 12.1

XATU0524 24 0.5 279 14.4

XATU0530 30 0.5 352 15.2

XATU0537 37 0.5 408 16.2

XATU0702 2 0.75 87 7.2

XATU0703 3 0.75 102 7.6

XATU0704 4 0.75 119 8.1

XATU0707 7 0.75 163 9.6

XATU0710 10 0.75 226 11.9

XATU0714 14 0.75 278 12.8

XATU0719 19 0.75 387 14.7

XATU0724 24 0.75 481 17.0

XATU0730 30 0.75 554 17.9

XATU0737 37 0.75 652 19.4

For Blue sheath, add 01 at the end of part number or add 00 for Black sheath.

www.fscables.com | sales@fscables.com


XAT Armoured Instrumentation

199

XAT-I Armoured Instrumentation Cable Individual Screen

XAT-I armoured instrumentation marine cables are manufactured in accordance with IEC 60092. Originally designed

for ship wiring, they have become popular throughout the petrochemical and process control industries due to their

low smoke, low gas generation and increased flame retardant properties. XAT-I offers a combined braid screen copper

armour and an additional foil screen around each pair to prevent crosstalk.

Can be used as an alternative to Nexans TCX (i), Finnish type RFE-HF (i), Prysmian HFX-ISA and UNIKA SH-CI-I-A.

CONSTRUCTION

Plain copper or tinned copper conductors, XLPE

insulation, each pair aluminium/polyester foil

screened with a drain wire, bedding or filler tape,

copper wire braid screen or tinned copper wire

braid armour, SHF1 Low Smoke Halogen Free

(LSHF) sheath – Blue or Grey.

CORE IDENTIFICATION

Pairs are colour coded or number coded. This can

vary depending on the manufacturer, please specify

if you have a preference.

TECHNICAL INFORMATION

Voltage Rating: 150/250V (300V)

Temperature Rating:

-40°C to +85°C or +90°C

Conductor Stranding: IEC 60228 class 2 or class 5,

plain copper or tinned copper

Bending Radius Static: 6 x overall diameter

Flame Retardant: IEC/BS EN 60332-1-2,

IEC/BS EN 60332-3-22 Cat A

Smoke Emission: IEC/BS EN 61034-1 & 2

Halogen Emission: IEC/BS EN 60754-1 & 2

Manufactured To:

3rd Party Approvals:

IEC 60092 series

Lloyds, DNV-GL, ABS, BV, Rina

XATI0707P

Part No.

No. of Pairs

Size

mm²

Weight

kg/km

O/D

mm

XATI0702P 2 0.75 190 11.0

XATI0704P 4 0.75 275 12.8

XATI0705P 5 0.75 205 13.0

XATI0707P 7 0.75 379 15.7

XATI0708P 8 0.75 400 16.5

XATI0710P 10 0.75 580 20.0

XATI0712P 12 0.75 640 20.7

XATI0714P 14 0.75 734 21.6

XATI0719P 19 0.75 934 24.1

XATI0724P 24 0.75 1163 28.4

XATI1502P 2 1.5 239 13.9

XATI1504P 4 1.5 415 16.0

XATI1507P 7 1.5 615 19.3

XATI1508P 8 1.5 705 22.0

XATI1510P 10 1.5 854 24.5

XATI1512P 12 1.5 975 26.0

XATI1514P 14 1.5 1103 26.7

XATI1519P 19 1.5 1399 29.9

For Blue sheath, add 01 at the end of part number or add 00 for Black sheath.

The IEC 60092 shipwiring standard allows for many variations in the cable construction including different

conductor stranding, the use of tinned or plain copper conductors, extruded inner sheaths or binder tapes and

optional core identification methods.

This can result in a change of weight, diameter, look and feel of the cable between different manufacturers. If

you need to size for glands or have a specific construction preference please specify at the time of enquiry.

Tel: 01727 840 841

MARINE & OFFSHORE


200

XAT-331 Armoured Power

XAT-331 Fire Resistant Armoured Power Cable

XAT-331 fire resistant marine power cables offer a lightweight method of wiring in applications where mechanical

protection is required and circuit integrity is critical whilst remaining sufficiently flexible for installation in confined spaces

or through difficult routes. Manufactured in accordance with European IEC 60092 series and fire resistant to

IEC 60331-21.

Can be used as an alternative to Nexans MPRX-331, Finnish type LKSM-FRHF, Prysmian HFX-A/Fr and UNIKA SH-PC-A-F.

XAT001519M

CONSTRUCTION

Plain copper or tinned copper conductors, mica

glass tape (or silicone insulation), XLPE insulation,

bedding tape, plain copper wire braid armour, SHF1

Low Smoke Halogen Free (LSHF) sheath - Orange

CORE IDENTIFICATION

Generally colour coded up to 5 core and numbered

cores above 5 core. Cables including a Green/

Yellow earth core are available on request.

TECHNICAL INFORMATION

Voltage Rating: 0.6/1kV

Temperature Rating:

-40°C to +85°C or +90°C

Conductor Stranding: IEC 60228 class 2 or class 5,

plain copper or tinned copper

Bending Radius Static: 6 x overall diameter

Flame Retardant: IEC/BS EN 60332-1-2,

IEC/BS EN 60332-3-22 Cat A

Fire Resistant: IEC 60331-21

Smoke Emission: IEC/BS EN 61034-1 & 2

Halogen Emission: IEC/BS EN 60754-1 & 2

Manufactured To:

3rd Party Approvals:

IEC 60092 series

Lloyds, DNV-GL, ABS, BV, Rina

Part No.

No. of Cores

Size

mm²

Weight

kg/km

O/D

mm

XAT001502M 2 1.5 119 10.3

XAT001503M 3 1.5 148 10.9

XAT001504M 4 1.5 188 12.0

XAT001505M 5 1.5 221 13.1

XAT001507M 7 1.5 303 14.7

XAT001512M 12 1.5 479 19.1

XAT001519M 19 1.5 715 22.5

XAT001524M 24 1.5 897 26.3

XAT001527M 27 1.5 950 26.0

XAT001537M 37 1.5 1304 30.3

XAT002502M 2 2.5 152 11.3

XAT002503M 3 2.5 195 11.9

XAT002504M 4 2.5 239 13.0

XAT002505M 5 2.5 308 14.7

XAT002507M 7 2.5 394 15.9

XAT002512M 12 2.5 643 20.9

XAT002519M 19 2.5 963 24.7

XAT004002M 2 4.0 197 12.5

XAT004003M 3 4.0 272 13.6

XAT004004M 4 4.0 344 15.0

XAT004005M 5 4.0 410 16.4

XAT006001M 1 6.0 125 7.9

XAT006002M 2 6.0 265 13.9

XAT006003M 3 6.0 348 14.7

XAT006004M 4 6.0 436 16.0

XAT006005M 5 6.0 531 17.6

For Blue sheath, add 01 at the end of part number or add 00 for Black sheath.

www.fscables.com | sales@fscables.com


XAT-331 Armoured Power

201

XAT-331 Fire Resistant Armoured Power Cable

Part No.

No. of Cores

Size

mm²

Weight

kg/km

O/D

mm

XAT010001M 1 10 185 9.3

XAT010002M 2 10 379 16.3

XAT010003M 3 10 516 17.5

XAT010004M 4 10 653 19.1

XAT010005M 5 10 802 21.1

XAT016001M 1 16 261 10.5

XAT016002M 2 16 544 18.9

XAT016003M 3 16 750 20.3

XAT016004M 4 16 967 22.4

XAT016005M 5 16 1192 24.7

XAT025001M 1 25 387 12.5

XAT025002M 2 25 812 22.9

XAT025003M 3 25 1121 24.3

XAT025004M 4 25 1454 26.9

XAT035001M 1 35 529 14.2

XAT035003M 3 35 1493 26.9

XAT035004M 4 35 1945 29.8

XAT050001M 1 50 692 16.1

XAT050003M 3 50 2004 31.4

XAT050004M 4 50 2612 34.8

XAT070001M 1 70 911 18.1

XAT070003M 3 70 2647 36.0

XAT070004M 4 70 3529 39.9

XAT095001M 1 95 1208 20.6

XAT095003M 3 95 3609 41.4

XAT120001M 1 120 1508 22.3

XAT120003M 3 120 4502 44.8

XAT150001M 1 150 1827 24.7

XAT150003M 3 150 5478 49.9

XAT185001M 1 185 2163 26.5

XAT240001M 1 240 2710 30.5

XAT300001M 1 300 3315 34.0

XAT016004M

For Blue sheath, add 01 at the end of part number or add 00 for Black sheath.

The IEC 60092 shipwiring standard allows for many variations in the cable construction including different

conductor stranding, the use of tinned or plain copper conductors, extruded inner sheaths or binder tapes and

optional core identification methods.

This can result in a change of weight, diameter, look and feel of the cable between different manufacturers. If

you need to size for glands or have a specific construction preference please specify at the time of enquiry.

Tel: 01727 840 841

MARINE & OFFSHORE


202

XAT-331 Armoured Instrumentation

XAT-331 Fire Resistant Armoured Instrumentation Cable Unscreened

XAT-331 armoured instrumentation marine cables are manufactured in accordance with IEC 60092 and IEC 60331-21

providing circuit integrity to critical circuits on ships and rigs. In the event of a fire, the cable will carry on functioning in

accordance with the tests. XAT-U-331 offers a combined braid screen copper armour and is remarkably flexible, resulting

in easy installation in confined spaces and through difficult routes.

Can be used as an alternative to Finnish type RFE-FRHF and UNIKA SH-CI-U-A-F.

XATU0704PM

CONSTRUCTION

Plain copper or tinned copper conductors, mica

glass tape (or silicone insulation), XLPE insulation,

bedding or filler tape, copper wire braid or tinned

copper wire braid armour, SHF1 Low Smoke

Halogen Free (LSHF) sheath - Orange.

CORE IDENTIFICATION

Pairs and cores are colour coded or number coded.

This can vary depending on the manufacturer,

please specify if you have a preference.

TECHNICAL INFORMATION

Voltage Rating: 150/250V (300V)

Temperature Rating:

-40°C to +85°C or +90°C

Conductor Stranding: IEC 60228 class 2 or class 5,

plain copper or tinned copper

Bending Radius Static: 6 x overall diameter

Flame Retardant: IEC/BS EN 60332-1-2,

IEC/BS EN 60332-3-22 Cat A

Fire Resistant: IEC 60331-21

Smoke Emission: IEC/BS EN 61034-1 & 2

Halogen Emission: IEC/BS EN 60754-1 & 2

Manufactured To:

3rd Party Approvals:

IEC 60092 series

Lloyds, DNV-GL, ABS, BV, Rina

Part No.

No. of Pairs

Size

mm²

Weight

kg/km

O/D

mm

XATU0701PM 1 0.75 55 9.0

XATU0702PM 2 0.75 200 14.0

XATU0704PM 4 0.75 285 16.0

XATU0707PM 7 0.75 445 19.5

XATU0710PM 10 0.75 615 24.0

XATU0712PM 12 0.75 685 25.0

Part No.

No. of Cores

Size

mm²

Weight

kg/km

O/D mm

XATU0702M 2 0.75 75 7.8

XATU0704M 4 0.75 141 9.0

XATU0707M 7 0.75 206 10.4

XATU0710M 10 0.75 285 13.0

XATU0714M 14 0.75 397 14.6

XATU0719M 19 0.75 485 16.0

XATU0724M 24 0.75 602 18.6

For Blue sheath, add 01 at the end of part number or add 00 for Black sheath.

The IEC 60092 shipwiring standard allows for many variations in the cable construction including different

conductor stranding, the use of tinned or plain copper conductors, extruded inner sheaths or binder tapes and

optional core identification methods.

This can result in a change of weight, diameter, look and feel of the cable between different manufacturers. If

you need to size for glands or have a specific construction preference please specify at the time of enquiry.

www.fscables.com | sales@fscables.com


XAT-331 Screened Instrumentation

203

XAT-331 Fire Resistant Armoured Instrumentation Cable Individual Screen

XAT-331 armoured instrumentation marine cables are manufactured in accordance with IEC 60092 and IEC 60331-21

providing circuit integrity to critical circuits on ships and rigs. In the event of a fire, the cable will carry on functioning in

accordance with the tests. XAT-I includes an overall copper wire braid screen with an additional foil screen around each

pair to reduce cross-talk. The cable is remarkably flexible resulting in easy installation in confined spaces and through

difficult routes.

Can be used as an alternative to Nexans TCX (i), Finnish type RFE-FRHF (i), Prysmian HFX-ISA/Fr and UNIKA SH-CI-I-A-F

CONSTRUCTION

Plain copper or tinned copper conductors, mica

glass tape (or silicone insulation), XLPE insulation,

each pair aluminium/polyester foil screened with a

drain wire, bedding filler tape, copper wire screen

or tinned copper wire braid armour, SHF1 Low

Smoke Halogen Free (LSHF) sheath - Orange.

CORE IDENTIFICATION

Pairs are colour coded or number coded. This can

vary depending on the manufacturer, please specify

if you have a preference.

TECHNICAL INFORMATION

Voltage Rating: 150/250V (300V)

Temperature Rating:

-40°C to +85°C or +90°C

Conductor Stranding: IEC 60228 class 2 or class 5,

plain copper or tinned copper

Bending Radius Static: 6 x overall diameter

Flame Retardant: IEC/BS EN 60332-1-2,

IEC/BS EN 60332-3-22 Cat A

Fire Resistant: IEC 60331-21

Smoke Emission: IEC/BS EN 61034-1 & 2

Halogen Emission: IEC/BS EN 60754-1 & 2

Manufactured To:

3rd Party Approvals:

IEC 60092 series

Lloyds, DNV-GL, ABS, BV, Rina

XATI1507PM

Part No.

No. of Pairs

Size

mm²

Weight

kg/km

O/D

mm

XATI0702PM 2 0.75 201 12.2

XATI0704PM 4 0.75 292 14.7

XATI0707PM 7 0.75 480 17.5

XATI0710PM 10 0.75 666 22.3

XATI0714PM 14 0.75 844 24.2

XATI0719PM 19 0.75 1062 27.0

XATI0724PM 24 0.75 1326 31.8

XATI1502PM 2 1.5 312 14.6

XATI1504PM 4 1.5 466 17.0

XATI1507PM 7 1.5 692 20.4

XATI1510PM 10 1.5 961 26.1

XATI1514PM 14 1.5 1232 28.5

XATI1519PM 19 1.5 1571 31.8

For Blue sheath, add 01 at the end of part number or add 00 for Black sheath.

The IEC 60092 shipwiring standard allows for many variations in the cable construction including different

conductor stranding, the use of tinned or plain copper conductors, extruded inner sheaths or binder tapes and

optional core identification methods.

This can result in a change of weight, diameter, look and feel of the cable between different manufacturers. If

you need to size for glands or have a specific construction preference please specify at the time of enquiry.

Tel: 01727 840 841

MARINE & OFFSHORE


204

XTS Single Core

XTS Single Core Cable

XTS is a marine specification flexible single core cable using cross-linked, Low Smoke Halogen Free (LSHF) insulation.

Applications include panel and instrument wiring as well as power to lighting, motors and battery leads or where the

cable is to be run through conduit.

Many other types of single core cables for marine applications are also available. Different insulation materials, fire

resistance options for critical circuits and cables capable of handling extreme climatic conditions are all available, please

let us know what you need.

This cable can be used as an alternative to Unika SH-W and the Finnish type LKEM-HF.

XTS000700

CONSTRUCTION

Plain copper or tinned copper conductors,

cross linked LSHF insulation.

TECHNICAL INFORMATION

Voltage Rating: 0.5mm² & 0.75mm²: 150/250V (300V)

1mm² and above: 0.6/1kV

Temperature Rating: to +90°C

Conductor Stranding:

Bending Radius Static:

IEC 60228 class 5, plain copper or

tinned copper

Flame Retardant: IEC/BS EN 60332-1-2

Smoke Emission: IEC/BS EN 61034-1 & 2

Halogen Emission: IEC/BS EN 60754-1 & 2

Manufactured To:

3rd Party Approvals:

IEC 60092 series

DNV-GL

XTS000701

Part No. Size mm² Weight kg/km O/D mm

XTS0005xx 0.5 10 2.3

XTS0007xx 0.75 13 2.5

XTS0010xx 1.0 16 2.7

XTS0015xx 1.5 22 3.0

XTS0025xx 2.5 33 3.4

XTS0040xx 4.0 50 4.0

XTS0060xx 6.0 60 4.4

XTS0100xx 10 112 5.4

XTS0160xx 16 173 6.4

XTS0250xx 25 270 8.3

XTS0350xx 35 371 9.6

XTS0500xx 50 526 11.2

XTS0700xx 70 731 13.0

XTS0950xx 95 985 15.2

XTS1200xx 120 1239 16.7

XTS1500xx 150 1556 18.8

XTS1850xx 185 1925 21.2

XTS2400xx 240 3055 24.0

XTS3000xx 300 3105 27.0

To show the colour required please replace xx in the part number with:

00 Black

01 Blue

02 Brown

03 Red

04 White

05 Grey

99 Green/Yellow

The IEC 60092 shipwiring standard allows for many variations in the cable construction including different

conductor stranding, the use of tinned or plain copper conductors, extruded inner sheaths or binder tapes and

optional core identification methods.

This can result in a change of weight, diameter, look and feel of the cable between different manufacturers. If

you need to size for glands or have a specific construction preference please specify at the time of enquiry.

www.fscables.com | sales@fscables.com


205

Special Manufacture

Introduction

Despite the phenomenal range of specialist cables

available on the market today a significant amount

of our business still comes from cables designed to

meet the customers exact requirements. It makes

a lot of sense to buy a cable that fits your needs

perfectly rather than run several cables that almost

do what you want.

Some of the cables that customers need are

composites using a variety of existing cables within

a single outer jacket for example combining coaxial

cables with power and signal cables to run up

camera masts. Or customers wanting multicore

versions of a single core cable that have very precise

electrical characteristics for monitoring. Others need

cables combining different elements for example

nylon tubes for pneumatic equipment alongside

multiple conductors and specialist grade sheaths

to protect against environmental challenges and

chemicals.

Contents

Special Manufacture 206 & 207

Colour Codes 210 - 213

Index 214 & 215

Cables Standards Cross Ref Chart 216

Whatever your requirements call us, we can talk

you through likely order quantities and production

times, any potential pitfalls and where you may be

able to save money and don’t forget you can order

up to a years requirement in one go which we’ll

hold in stock so you can call it off for immediate

delivery.

On page 206 there is an outline of what can be

done to standard cables to make them better suited

to your needs. On page 207 there is a brief checklist

to help us work together to design your perfect

cable. Call us now and start the ball rolling.

Tel: 01727 840 841

SPECIAL MANUFACTURE


206

Special Manufacture

Custom-made and Composite Cables

You specify, we supply – with quantities as low as 100 metres in some cases. The options outlined

on these pages are the main variations and can be combined in any way to meet your particular

specifications. This can be as basic as a special colour code or jacket colour, right through to cables

containing mixed core sizes or elements with various levels of screening or armouring. Talk to us

about cost-effective solutions for applications that are not mentioned here. Also, see the next

page for things to consider when specifying or designing a cable.

Outdoor and Duct Grade Sheaths

In situations where the cable runs outside or through ducts polyethylene sheathing is the ideal

solution. This material is tough, water-resistant and has natural low friction, making it easy to pull

through ducts. It is also ideal for clipping to the outside of buildings offering good resistance to

sunlight.

Two types of polyethylene are commonly used, Low Density (LDPE) and High Density (HDPE). LDPE

offers reasonable flexibility and mechanical protection. It is particularly suited to small data cables,

while HDPE is much stiffer and is normally used for larger cables where no flexibility is required.

Even quantities as low as 100m can be oversheathed, which allows you to use the same basic

cable throughout an installation but with the added protection needed.

Special Colours

Many cables can be supplied in a range of jacket colours. Existing cables can be coloured by

oversheathing to match an existing colour scheme or for identifying circuits, for example alarm or

data wiring. Talk to us about the options available.

Braiding

For added protection cables can be braided with a galvanised steel wire braid (GSWB) stainless

steel or heavy tinned copper wire. It is then over sheathed in a material of your choice. Braiding

maintains a degree of flexibility whilst offering mechanical protection or electrical screening. This

may be important during installation or if the equipment needs to be moved for maintenance or is

subject to vibration.

Armouring

Armouring is best suited for fixed installations and particularly direct burial either galvanised steel

wire (SWA) or aluminium armour can be applied. Both types of protection are then sheathed with

either an exterior grade PVC or polyethylene. Low Smoke Halogen Free sheaths for installations

where fire safety is critical are also available. Standard stock cables can be braided or armoured for

quantities as low as 100m.

Custom Made Leads & Assemblies

For most jobs time is money and you cannot afford to make a mistake. To reduce installation time

and cost many system manufacturers are now operating a plug and play design allowing the

installer to simply plug pre-manufactured leads into modules for right first time termination.

To meet these growing demands we are able to supply many of the coax, data and

instrumentation cables listed in this book as pre-terminated leads to save you time and money. All

we need to know is the length and the connector type you require - we will do the rest.

Printed Sheaths

Cables can be printed with your company name, telephone number or an identification code such

as a batch or location number.

www.fscables.com | sales@fscables.com


Special Manufacture

207

Cable Considerations

Here are a few points to think about when designing your custom cable. But don’t forget we are here to help and with

many years experience there isn’t a lot we haven’t come across so we can help you avoid a lot of pitfalls and suggest the

most effective solution.

Choosing the core size and conductor type is the first important step ensuring that you take into account the current

carrying capacity required, volts drop and resistance of the material. Is the cable going to be flexed either during installation

or once installed?

Do you require different elements within the cable, i.e. coax, data, power, signal, optical fibre or pneumatic

tubes to name just a few?

This can save time in installation and offer better protection to the components in the cable. It may also result in a neater job.

Does the cable need to deal with any specific climatic conditions, i.e. heat, cold, sunlight, sea or freshwater?

If the cable is only for temporary installations this may not be so relevant but most installations require a cable to last for

years so it’s worth getting it right in the first place.

Will the cable be used in an application where third party standards must be met, i.e. Low Smoke Halogen Free,

marine approvals or national approvals?

Testing can also be important but fire tests in particular can be expensive.

What lengths do you need it supplied in and what lengths will the cable be used in, what is the total quantity

you need and what type of reels or boxes do you want it packed in?

This can be very important in reducing wastage or making the cable easy to handle or install.

Are there likely to be any solvents, oils or contaminants that the cable will come in contact with?

Some jacket materials are resistant to oils, acids and waste but still retain flexibility others will breakdown or age

permanently if contaminated.

What type of mechanical protection is needed?

This may vary from a light PVC jacket to a heavy steel wire armour. Braids can give good protection whilst maintaining

flexibility.

Is the cable likely to emit or be affected by Electromagnetic Interference?

If this is the case screens, foils, braids or lapped screens may be necessary.

What voltage is the cable going to carry, is it AC or DC?

Will the cable run next to any other cables carrying different voltages?

Are there any restrictions on overall diameters?

This may affect glanding, connectors or the containment used.

Do you need to match the colour of the jacket or outer sheath to suit other equipment?

If so, you could use a different colour to identify particular circuits.

Tel: 01727 840 841

SPECIAL MANUFACTURE


208

AWG/Metric Conversion

American Wire Gauge to Metric Conversion

Listed below are some of the most popular strandings, however, many other combinations exist.

Resistance figures are approximate and are given for guidance only.

AWG

Cross Section

mm 2

Stranding

Resistance

Ohm/km

38 0.008 1 x 0.10 2125

38 0.009 7 x 0.04 1930

36 0.013 1 x 0.12 1360

36 0.014 7 x 0.05 1217

34 0.020 1 x 0.16 856

34 0.022 7 x 0.06 777

32 0.032 1 x 0.20 538

32 0.034 7 x 0.08 538

32 0.035 19 x 0.05 446

30 0.051 1 x 0.25 338

30 0.057 7 x 0.10 338

30 0.059 19 x 0.06 286

28 0.080 1 x 0.32 213

28 0.089 7 x 0.12 213

28 0.090 19 x 0.08 186

26 0.128 1 x 0.40 134

26 0.141 7 x 0.16 122

26 0.155 19 x 0.10 113

24 0.205 1 x 0.51 84

24 0.227 7 x 0.20 76

24 0.241 19 x 0.12 69

22 0.324 1 x 0.64 53

22 0.355 7 x 0.25 48

22 0.382 19 x 0.16 45

20 0.519 1 x 0.81 33

20 0.563 7 x 0.32 30.4

AWG

Cross Section

mm 2

Stranding

Resistance

Ohm/km

16 1.30 1 x 1.29 13.2

16 1.23 19 x 0.28 14.0

14 2.08 1 x 1.62 8.28

14 1.94 19 x 0.36 8.86

12 3.31 1 x 2.05 5.20

12 3.08 19 x 0.45 5.58

10 5.26 1 x 2.58 3.28

10 5.26 19 x 0.6 3.28

8 8.38 1 x 3.26 2.06

8 8.35 19 x 0.75 2.06

6 13.29 1 x 4.11 1.59

6 13.29 19 x 0.96 1.59

4 21.15 1 x 5.18 0.815

4 21.14 19 x 1.19 0.815

2 33.63 1 x 6.54 0.513

2 33.61 19 x 1.50 0.513

1 42.41 1 x 7.34 0.424

1 42.38 19 x 1.68 0.424

1/0 53.4 19 x 1.89 0.253

2/0 67.4 19 x 2.17 0.291

4/0 107 19 x 2.68 0.182

250 MCM 127 37 x 2.09 0.139

300 MCM 152 37 x 2.29 0.119

350 MCM 177 37 x 2.47 0.102

400 MCM 202 37 x 2.64 0.091

500 MCM 253 37 x 2.95 0.072

20 0.616 19 x 0.20 28.3

18 0.785 16 x 0.25 21.2

18 0.823 1 x 1.02 20.9

18 0.90 7 x 0.40 19.2

18 0.96 19 x 0.25 17.9

www.fscables.com | sales@fscables.com


Stranding Chart

209

IEC/BS EN 60228 Conductors for insulated cables

Cross Section

mm 2

Nearest

AWG Size*

Stranding

Class 1

Stranding

Class 2

Resistance

Ohm/km

Classes 1 & 2

Stranding

Class 5

Stranding

Class 6

Resistance

Ohm/km

Classes 5 & 6

Approx

Weight

kg/km

0.14 26 - - - - 18 x 0.10 138 1.35

0.25 24 - - - 14 x 0.16 32 x 0.10 79 2.4

0.34 22 - - - 19 x 0.16 42 x 0.10 57 3.3

0.50 20 1 x 0.80 7 x 0.30 36.0 16 x 0.21 28 x 0.16 38 4.8

0.75 18 1 x 0.97 7 x 0.37 24.5 24 x 0.21 42 x 0.16 26 7.2

1.0 18 1 x 1.13 7 x 0.43 18.1 32 x 0.21 56 x 0.16 19.5 9.6

1.5 16 1 x 1.38 7 x 0.53 12.1 30 x 0.26 84 x 0.16 13.3 14.4

2.5 14 1 x 1.78 7 x 0.67 7.41 50 x 0.26 140 x 0.16 7.98 24

4.0 12 1 x 2.26 7 x 0.85 4.61 56 x 0.31 224 x 0.16 4.95 38

6.0 10 1 x 2.76 7 x 1.04 3.08 84 x 0.31 192 x 0.21 3.3 58

10 8 1 x 3.57 7 x 1.35 1.83 80 x 0.41 320 x 0.21 1.91 96

16 6 1 x 4.5 7 x 1.70 1.15 128 x 0.41 512 x 0.21 1.21 154

25 4 – 7 x 2.14 0.72 200 x 0.41 800 x 0.21 0.78 240

35 2 – 7 x 2.52 0.52 280 x 0.41 1120 x 0.21 0.55 336

50 1/0 – 19 x 1.78 0.39 400 x 0.41 705 x 0.31 0.39 480

70 2/0 – 19 x 2.14 0.27 356 x 0.51 990 x 0.31 0.27 672

95 3/0 – 19 x 2.52 0.19 485 x 0.51 1340 x 0.31 0.21 912

120 250mcm – 37 x 2.03 0.15 614 x 0.51 1690 x 0.31 0.16 1152

150 300mcm – 37 x 2.25 0.12 765 x 0.51 2123 x 0.31 0.13 1440

185 400mcm – 37 x 2.52 0.10 944 x 0.51 1470 x 0.41 0.11 1776

240 500mcm – 61 x 2.25 0.07 1225 x 0.51 1905 x 0.41 0.08 2304

300 600mcm – 61 x 2.52 0.06 1530 x 0.51 2385 x 0.41 0.064 2880

400 750mcm – 61 x 2.85 0.05 2035 x 0.51 – 0.068 3840

500 1000mcm – 61 x 3.20 0.04 1768 x 0.60 – 0.0384 4800

The number of strands according to IEC/BS EN 60228 (replacing the old BS 6360) shown in classes 1 & 2 is obligatory.

Stranding shown in classes 5 & 6 gives the maximum strand diameters and may have fewer strands provided the conductor does not exceed the

resistance figures shown. In either case, the standard gives the maximum resistance in ohms/km that is permissible for non-tinned conductors.

*AWG sizes are approximate and for information only. Please contact us for exact sizing.

Tel: 01727 840 841

TECHNICAL


210

Colour Codes - American Style

Colour Chart 1: Conductor/Colour

1 Black

2 White

3 Red

4 Green

5 Brown

6 Blue

7 Orange

8 Yellow

9 Purple

10 Grey

11 Pink

12 Tan

Colour Chart 2: Conductor/Colour

1 Black

2 White

3 Red

4 Green

5 Orange

6 Blue

7 White/Black

8 Red/Black

9 Green/Black

10 Orange/Black

11 Blue/Black

12 Black/White

13 Red/White

14 Green/White

15 Blue/White

16 Black/Red

17 White/Red

18 Orange/Red

19 Blue/Red

20 Red/Green

21 Orange/Green

22 Black/White/Red

23 White/Black/Red

24 Red/Black/White

25 Green/Black/White

26 Orange/Black/White

27 Blue/Black/White

28 Black/Red/Green

29 White/Red/Green

30 Red/Black/Green

31 Green/Black/Orange

32 Orange/Black/Green

33 Blue/White/Orange

34 Black/White/Orange

35 White/Red/Orange

36 Orange/White/Blue

37 White/Red/Blue

38 Black/White/Green

39 White/Black/Green

40 Red/White/Green

41 Green/White/Blue

42 Orange/Red/Green

43 Blue/Red/Green

44 Black/White/Blue

45 White/Black/Blue

46 Red/White/Blue

47 Green/Orange/Red

48 Orange/Red/Blue

49 Blue/Orange/Red

50 Black/Orange/Red

Colour Chart 3: Pair/Number Colour Combination

1 Black/Red

2 Black/White

3 Black/Green

4 Black/Blue

5 Black/Yellow

6 Black/Brown

7 Black/Orange

8 Red/White

9 Red/Green

10 Red/Blue

11 Red/Yellow

12 Red/Brown

13 Red/Orange

14 Green/White

15 Green/Blue

16 Green/Yellow

17 Green/Brown

18 Green/Orange

19 White/Blue

20 White/Yellow

21 White/Brown

22 White/Orange

23 Blue/Yellow

24 Blue/Brown

25 Blue/Orange

26 Brown/Yellow

27 Brown/Orange

28 Orange/Yellow

29 Purple/Orange

30 Purple/Red

31 Purple/White

32 Purple/Dark Green

33 Purple/Light Blue

34 Purple/Yellow

35 Purple/Brown

36 Purple/Black

37 Grey/White

Colour Chart 5: Western Electric Standard & CW1308 Telephone Cable Colour Chart

Pair number/colour combination. The second colour denotes the band or stripe, however due to environmental

issues the cores may be solid colours instead of bi-colours.

1 White/Blue Blue/White

2 White/Orange Orange/White

3 White/Green Green/White

4 White/Brown Brown/White

5 White/Grey Grey/White

6 Red/Blue Blue/Red

7 Red/Orange Orange/Red

8 Red/Green Green/Red

9 Red/Brown Brown/Red

10 Red/Grey Grey/Red

11 Black/Blue Blue/Black

12 Black/Orange Orange/Black

13 Black/Green Green/Black

14 Black/Brown Brown/Black

15 Black/Grey Grey/Black

16 Yellow/Blue Blue/Yellow

17 Yellow/Orange Orange/Yellow

18 Yellow/Green Green/Yellow

19 Yellow/Brown Brown/Yellow

20 Yellow/Grey Grey/Yellow

21 Purple/Blue Blue/Purple

22 Purple/Orange Orange/Purple

23 Purple/Green Green/Purple

24 Purple/Brown Brown/Purple

25 Purple/Grey Grey/Purple

26 Pink/Blue Blue/Pink

27 Pink/Orange Orange/Pink

28 Pink/Green Green/Pink

29 Pink/Brown Brown/Pink

30 Pink/Grey Grey/Pink

www.fscables.com | sales@fscables.com


Colour Codes - European / UK

211

CW1600 Colour Code

Pairs

Colour of insulation

A-Wire B-Wire

1 White/Blue Blue

2 White/Orange Orange

3 White/Green Green

4 White/Brown Brown

5 White/Grey Grey

6 Red/Blue Blue

7 Red/Orange Orange

8 Red/Green Green

9 Red/Brown Brown

Pairs

Colour of insulation

A-Wire B-Wire

10 Red/Grey Grey

11 Black/Blue Blue

12 Black/ Orange Orange

13 Black/Green Green

14 Black/Brown Brown

15 Black/Grey Grey

16 Yellow/Blue Blue

17 Yellow/Orange Orange

18 Yellow/Green Green

Pairs

Colour of insulation

A-Wire B-Wire

19 Yellow/Brown Brown

20 Yellow/Grey Grey

21 Violet/Blue Blue

22 Violet/Orange Orange

23 Violet/Green Green

24 Violet/Brown Brown

25 Violet/Grey Grey

On cables with over 25 pairs the first 20 pairs will be repeated with coloured separators or binder tapes to indicate each bundle.

CW1128 & CW1128/1198 Colour Coding

Pair A-Wire B-Wire

1 White Blue

2 White Orange

3 White Green

4 White Brown

5 White Grey

6 Red Blue

7 Red Orange

8 Red Green

9 Red Brown

10 Red Grey

Colours of tape lappings

1 Blue

2 Orange

3 Green

4 Brown

5 Grey

6 White

7 Red

8 Black

9 Yellow

10 Violet

Other colour codes for external telephone

cables also exist.

Def Style Miniature Cables

1 Red

2 Blue

3 Green

4 Yellow

5 White

6 Black

7 Brown

8 Violet

9 Orange

10 Pink

11 Turquoise

12 Grey

13 Red/Blue

14 Green/Red

15 Yellow/Red

16 White/Red

17 Red/Black

18 Red/Brown

19 Yellow/Blue

20 White/Blue

21 Blue/Black

22 Orange/Blue

23 Green/Blue*

24 Grey/Blue*

25 Yellow/Green

26 White/Green*

27 Green/Black

28 Orange/Green*

29 Grey/Green

30 Yellow/Brown

31 White/Brown

32 Brown/Black

33 Grey/Brown

34 Yellow/Violet

35 Violet/Black

36 White/Violet

* Note: The colour code of 25 core cables has core colours 23 & 24

replaced with colours 26 & 28.

For colour codes above 36 cores please ask for details.

HD 308 S2 BS 7671 Amendment 2: 2004 Colour Code European Harmonised Standard For Mains Cables

The new colour code for mains cables is obligatory and applies to flexible and fixed cables connected to the

mains. It does not apply to control or signal.

Two Core

Blue

Brown

Three Core

Green/Yellow

Blue

Brown

Cables without earth core:

Brown

Black

Grey

Four Core

Green/Yellow

Brown

Black

Grey

or Green /Yellow

Blue

Brown

Black

Cables without earth core:

Blue

Brown

Black

Grey

Five Core

Green/Yellow

Blue

Brown

Black

Grey

Cables without earth core:

Blue

Brown

Black

Grey

Black

Tel: 01727 840 841

TECHNICAL


212

Colour Codes

DIN 47100 Colour Codes

Twisted pair cable with DIN 47100 colour code is identified by twisting colour 1 with colour 2, colour 3 with

colour 4, colour 5 with colour 6 and so on.

1 White 16 Yellow/Brown 31 Green/Blue

2 Brown 17 White/Grey 32 Yellow/Blue

3 Green 18 Grey/Brown 33 Green/Red

4 Yellow 19 White/Pink 34 Yellow/Red

5 Grey 20 Pink/Brown 35 Green/Black

6 Pink 21 White/Blue 36 Yellow/Black

7 Blue 22 Brown/Blue 37 Grey/Blue

8 Red 23 White/Red 38 Pink/Blue

9 Black 24 Brown/Red 39 Grey/Red

10 Violet 25 White/Black 40 Pink/Red

11 Grey/Pink 26 Brown/Black 41 Grey/Black

12 Red/Blue 27 Grey/Green 42 Pink/Black

13 White/Green 28 Yellow/Grey 43 Blue/Black

14 Brown/Green 29 Pink/Green 44 Red/Black

15 White/Yellow 30 Yellow/Pink

NYY-J & NYY-O Colour Code

No. of Cores NYY-J with protective earth NYY-O without protective earth

1 Core Green/Yellow Black

2 Core N/A Brown, Blue

3 Core Brown, Blue, G/Y Brown, Black, Grey

4 Core Brown, Black, Grey, G/Y Brown, Blue, Black, Grey

5 Core Brown, Blue, Black, Grey, G/Y Brown, Blue, Black, Black, Grey

7 Core & Above Number Coded with a G/Y Number Coded

JB & OB Colour Code for YY, SY & CY

No. of Cores JB - Colour Coded with Green/Yellow OB - Colour Coded without Green/Yellow

2 Cores N/A Brown, Blue

3 Cores Brown, Blue, G/Y Brown, Black, Grey

4 Cores Brown, Black, Grey, G/Y Brown, Blue, Black, Grey

5 Cores Brown, Blue, Black, Grey, G/Y Brown, Blue, Black, Black, Grey

JZ is Number Coded with a Protective Green/Yellow Earth.

OZ is Number Coded without a Protective Green/Yellow Earth.

www.fscables.com | sales@fscables.com


Colour Codes - BS 5308/PAS5308

213

BS 5308 Part 1 Colour Code

Unscreened & Collective Screened

Pair No. A-Wire B-Wire

1 Black Blue

2 Black Green

3 Blue Green

4 Black Brown

5 Blue Brown

6 Green Brown

7 Black White

8 Blue White

9 Green White

10 Brown White

11 Black Red

12 Blue Red

13 Green Red

14 Brown Red

15 White Red

16 Black Orange

17 Blue Orange

18 Green Orange

19 Brown Orange

20 White Orange

21 Red Orange

22 Black Yellow

23 Blue Yellow

24 Green Yellow

25 Brown Yellow

26 White Yellow

27 Red Yellow

28 Orange Yellow

29 Black Grey

30 Blue Grey

31 Green Grey

32 Brown Grey

33 White Grey

34 Red Grey

35 Orange Grey

36 Yellow Grey

37 Black Grey

38 Blue Grey

39 Green Violet

40 Brown Violet

41 White Violet

42 Red Violet

43 Orange Violet

44 Yellow Violet

45 Grey Violet

46 Black Turquoise

47 Blue Turquoise

48 Green Turquoise

49 Brown Turquoise

50 White Turquoise

Single Quad (2 pair):

Single Triple:

Black, Blue, Green, Brown

Blue, Black, Green

Individually screened pairs can also be identified by a polyester tape

over black and blue pairs.

BS 5308 Part 2 Colour Code

Unscreened & Collective Screened

Pair No. A-Wire B-Wire

1 White Blue

2 White Orange

3 White Green

4 White Brown

5 White Grey

6 Red Blue

7 Red Orange

8 Red Green

9 Red Brown

10 Red Grey

11 Black Blue

12 Black Orange

13 Black Green

14 Black Brown

15 Black Grey

16 Yellow Blue

17 Yellow Orange

18 Yellow Green

19 Yellow Brown

20 Yellow Grey

21 White-Blue Blue

22 White-Blue Orange

23 White-Blue Green

24 White-Blue Brown

25 White-Blue Grey

26 Red-Blue Blue

27 Red-Blue Orange

28 Red-Blue Green

29 Red-Blue Brown

30 Red-Blue Grey

31 Blue-Black Blue

32 Blue-Black Orange

33 Blue-Black Green

34 Blue-Black Brown

35 Blue-Black Grey

36 Yellow-Blue Blue

37 Yellow-Blue Orange

38 Yellow-Blue Green

39 Yellow-Blue Brown

40 Yellow-Blue Grey

41 White Orange Blue

42 White Orange Orange

43 White Orange Green

44 White Orange Brown

45 White Orange Grey

46 Orange-Red Blue

47 Orange-Red Orange

48 Orange-Red Green

49 Orange-Red Brown

50 Orange-Red Grey

Single Quad (2 pair):

Single Triple:

Blue, Green, Orange, Brown

Blue, White, Orange

Individually screened pairs can also be identified by a polyester tape

over white and blue pairs.

Tel: 01727 840 841

TECHNICAL


214

Index

Product

Page

2491B 86

318*B 87

6701B 86

A

AICI Fibre Cables, Marine 191

Alternative to Belden 8 to 23

Armoured Data & Coaxial 67

ASI Bus Cables 178

AWG/Metric Conversion Chart 208

B

Bedded CY 113

Blind Control Cables 49

BS 3G 210 168

BS 5308 114 to 117

BS5467 148

BS6724 149

BS8436 154

Burglar Alarm Cables 64, 65

C

Cable Standards Cross Reference Chart 216

CAN Bus Cables 176

CAN Bus, Marine 186

Cat 5E 26

Cat 5E HDBaseT 27

Cat 5E, Marine 182

Cat 6 28

Cat 6 HDBaseT 29

Cat 6, Marine 182

Cat 6A 30

Cat 6A HDBaseT 30

Cat 6A, Marine 182

Cat 7 31

Cat 7, Marine 183

Cat 7A 31

Cat 7A, Marine 183

Cat 8 31

Cat 8.1, Marine 183

CC-Link Cables 179

Coaxial Cables, Antennax 136, 137

Coaxial Cables, Composite 139

Coaxial Cables, Corrugated, Marine 185

Coaxial Cables, Low Loss 138

Coaxial Cables, RF 400, Marine 185

Coaxial Cables, RG 128 to 131

Coaxial Cables, RG, Marine 184

Coaxial Cables, Satellite 134, 135

Coaxial Cables, URM 132, 133

Product

Page

Colour Codes 212

Colour Codes - American Style 210

Colour Codes - BS 5308 213

Colour Codes - European / UK 211

Composite Coaxial & Door Entry 69

Control Cables, External 68

Control4 Cables 50

Crestron Cables 50

CW1128 144

CW1128/1198 145

CW1308 142

CW1308B 146

CW1411 146

CW1415 146

CW1420 146

CW1600 143

CY LSHF 90, 91

D

DALI Cables 52

Def-Stan, LSHF 96, 97

Def-Stan, PVC 110 to 112

DeviceNet 176

DMX Cables 44

Drum Reeling Cables 162

E

Echelon LonWorks 53, 177

F

Fibre Cables, Marine 188 to 191

Fibre Optic Cable 72 to 83

Fibre Optic Cable Fire Resistant 80, 81

Fieldbus Cables 174

Firetuf Coaxial 56

Firetuf Data 56

Flat PVC Cables 161

FP Plus 60

FP100 57

FP200 58

FP600S 62

FST Cables 42

FT120 61

FT30 59

G

G-Temp 600 170

H

H05RR-F 160

H05VVH6-F 161

H05Z1Z1-F 87

www.fscables.com | sales@fscables.com


Index

215

Product

Page

H07RN-F 156, 157

H07VVH6-F 161

H07Z-K 86

HD Media Composite Cables 38 to 41

Honeywell Door Entry Cables 51

I

Industrial Bus, Marine 186

Industrial Ethernet Cables 179

Interbus Cables 177

K

KNX Cables 48

L

Lan Cables, External 32

Lighting Control Cables 49

LiHCH 94

LiHCH-TP 95

Line Level Audio 42

LiYCY Din 47100 PVC 107

LiYCY LSHF 90, 91

LiYCY PVC 104, 105

LiYCY-TP 108, 109

LiYY PVC 106

M

Microphone Cables 43

Modbus Cables 178

N

N2XH 152, 153

NSHTou 162

NYY 150, 151

O

Outdoor Data & Coaxial 66

P

Pilz Cables 179

Profibus Cables 175

Profibus, Marine 186

P-Temp 260 169

PTFE Single Cores 168

Purple Pipe 63

Q

QFCI Fibre Cables, Marine 188 to 190

R

RiserFlex 0.6/1kV 92

RiserShield 0.6/1kV 93

Robotic Cables, Bus 126

Robotic Cables 120 to 123

Robotic Cables, Encoder 124

Robotic Cables, Servo & Feedback 125

Product

Page

S

Safe-T-Shield 154

Sensalink Cables 179

Shipboard Cables 192 to 204

Silicone, SiD 165

Silicone, SiF 164

Silicone, SiF-GL 165

Silicone, SiF-G-SI-HT 165

Silicone, SiF-HT 165

Silicone, SiHF 166

Silicone, SiHF-C-Si 167

Silicone, SiHF-GL-P 167

Silicone, SiHFP 167

Simmtronic Cables 46

Snake Cables 44

Speaker Cables External 36

Speaker Cables Multicore 34, 35

Speaker Cables Parallel 37

Spiral Cables 118, 119

Star Quad Cables 43

Stranding Chart 209

SY LSHF 98

SY PVC 102, 103

T

Thermocouple Cables 171

Thorn Lighting Cables 50

Transducer & Load Cell Cables 24

Tree Cable for Loxone Systems 51

Trend Cables 47

W

WRAS Cables 158, 159

X

XAT Armoured Power 196, 197

XAT Instrumentation 198, 199

XAT-331 Armoured Instrumentation 202, 203

XAT-331 Armoured Power 200, 201

XT Screened Instrumentation 194, 195

XT Unarmoured Power 192, 193

XTS Single Core 204

Y

YY LSHF 88, 89

YY PVC 100, 101

Tel: 01727 840 841

TECHNICAL


216

Cable Standards Cross Reference Chart

Conductor Stranding

BS EN 60228

Conductor class, stranding and resistance for

electric cables.

Alternative Standard References

IEC 60228 BS 6360 VDE 0295

Flame Retardant Tests

BS EN 60332-1-2 Vertical flame test on a single wire or cable. IEC 60332-1-2

BS EN 60332-3-21 Cat

A F/R

BS EN 60332-3-22 Cat A

BS EN 50266-2-2 Cat A

BS EN 60332-3-23 Cat B

BS EN 50266-2-3 Cat B

BS EN 60332-3-24 Cat C

BS EN 50266-2-4 Cat C

BS EN 60332-3-25 Cat D

Bunched cables 40 minute burn test.

7.0 litres/metre of combustible material.

Bunched cables 40 minute burn test.

7.0 litres/metre of combustible material.

Bunched cables 40 minute burn test.

3.5 litres/metre of combustible material.

Bunched cables 20 minute burn test.

1.5 litres/metre of combustible material.

Bunched cables 20 minute burn test.

0.5 litres/metre of combustible material.

Alternative Standard References

IEC 60332-3-21

Cat A F/R

IEC 60332-3-22

Cat A

IEC 60332-3-23

Cat B

IEC 60332-3-24

Cat C

IEC 60332-3-25

Cat D

IEC 60332-1

VDE 0482-265-2-1

EN 50266-2-1 Cat A F/R

IEC 60332-3A

VDE 0482-266-2-2 Cat A

IEC 60332-3B

VDE 0482-266-2-3 Cat B

IEC 60332-3C

VDE 0482-266-2-4 Cat C

EN 50266-2-5 Cat D

BS 4066-1

BS 4066 pt 3A

BS 4066 pt 3B

BS 4066 pt 3C

Fire Resistant Circuit Integrity Tests

IEC 60331-21

IEC 60331-23

IEC 60331-25

IEC 60331-1 & 2

BS 6387 Cat C

BS 6387 Cat W

BS 6387 Cat Z

BS 8434-1 Standard

BS 8434-2 Enhanced

EN 50200 PH30

EN 50200 PH60

EN 50200 PH120

Alternative Standard References

Cables up to and including 0.6/1kV.

90 minutes minimum @ 750°C with fire. IEC 60331 VDE 0472 FE180

Data cables. 90 minutes @ 750°C with fire.

Optical fibre cables. 90 minutes @ 750°C with fire.

Cables up to and including 0.6/1kV.

120 minutes @ 830°C with fire & mechanical shock.

Circuit integrity for 3 hours @ 950°C with fire.

Circuit integrity for 30 minutes @ 650°C.

15 mins with fire, 15 mins with fire & water spray.

Circuit integrity for 15 minutes @ 950°C with fire

& mechanical shock.

Circuit integrity for 30 minutes @ 850°C.

15mins fire, 15 mins with fire & water spray.

Circuit integrity for 2 hours @ 950°C. 60 mins fire

& shock, 60 mins fire, shock & water spray.

Circuit integrity for 30 minutes @ 850°C with fire

and mechanical shock.

Circuit integrity for 60 minutes @ 850°C with fire

and mechanical shock.

Circuit integrity for 120 minutes @ 850°C with fire

and mechanical shock.

IEC 60331-31

BS 5839-1 Clause 26.2d

BS 5839-1 Clause 26.2e

Similar to BS 8434-1 without the water spray test

Similar to BS 8434-2 without the water spray test

Halogen Gas Emission Tests

BS EN 60754-1

BS EN 60754-2

Determination of halogen acid gas generation.

Not suitable for materials with less than 5mg/g

halogen acid (5% content)

Not suitable for Low Smoke Halogen Free

classification.

Determination of the degree of acidity of gases

evolved during combustion by measuring pH levels

and conductivity.

Suitable for Low Smoke Halogen Free

classification.

Alternative Standard References

EN 50267-2-1

IEC 60754-1

EN 50267-2-2

IEC 60754-2

BS 6425-1 VDE 0482-267-2-1

BS 6425-2 VDE 0482-267-2-2

Smoke Generation Tests

BS EN 61034-1

BS EN 61034-2

Test apparatus for measuring the smoke density

of cables.

Test proceedure and requirements. Minimum of

60% light transmission.

Alternative Standard References

IEC 61034-1 EN 50268-1 BS 7622-1 VDE 0482-1034-1

IEC 61034-2 EN 50268-2 BS 7622-2 VDE 0482-1034-2

www.fscables.com | sales@fscables.com