23.09.2025 Views

Infinitas Mini Implant System Atlas - A Procedural Guide to Predictable Orthodontic Anchorage - Digital

Transform your PDFs into Flipbooks and boost your revenue!

Leverage SEO-optimized Flipbooks, powerful backlinks, and multimedia content to professionally showcase your products and significantly increase your reach.

Infinitas Mini Implant System Atlas

A Procedural Guide to Predictable

Orthodontic Anchorage

Exclusive to Infinitas

Users Group - BOC 2025 Edition



Contents

Designed by an Orthodontist,

for Orthodontists.................................................... 4

Why Choose Infinitas?.......................................... 5

DB Digital...................................................................6

Connecting with DB Digital..................................7

Infinitas Stent Guidance System.........................8

Infinitas palatal applications...............................9

Clinical Applications

- Intrusion.......................................................10

- Expansion....................................................11

- Mesialisation.............................................. 12

- Molar Protraction......................................13


Designed by an Orthodontist,

trusted by Orthodontists worldwide.

We owe much of our success to the dedication

of Dr Richard Cousley, who became our clinical

advisor, educator and collaborator.

Dr Cousley has amassed a wealth of experience

treating complex cases both as a Consultant

Orthodontist in both UK hospitals and private

practice.

He has published a landmark textbook on miniimplant

anchorage (second edition published

in 2020), plus numerous papers on clinical

and technical innovations in orthodontic bone

anchorage and biomechanics, and lectures widely

on this topic.

If you haven’t already, we invite you to book on to

one of our Infinitas course dates.

We created Infinitas mini-implants to satisfy the

demand for a simple and user-friendly miniimplant

system which met the needs of today’s

orthodontists.

The popular Infinitas course will build on your

existing confidence; introduce you to like-minded

individuals passionate about world class bone

anchorage and, give you the opportunity to ask

the Infinitas team questions directly.

Get Your Skills In Shape

Click here to view all our latest courses

4

Infinitas Mini Implant System Atlas

+44 (0) 1535 656999


Why Choose Infinitas?

Precision, reliability and simplicity in every case.

With its versatility, ease of use, and digital integration, the Infinitas Mini Implant System

is designed to support every indication for use—helping clinicians achieve predictable

results with maximum efficiency.

Unique Head Designs for Versatile Applications

The standard Infinitas head allows secure

attachment of all common forms of traction.

Auxiliaries such as closing coil springs, elastomeric

chain, and .021x.025 rectangular wire are held firmly

on a single traction level.

The new round head mini implants have been

purpose-designed for use with palatal sliders and

distalising appliances—broadening the scope of

treatment possibilities.

Self-Drilling Insertion

Every Infinitas mini implant is self-drilling, ensuring

easy insertion and maximum stability.

The advanced thread design eliminates the need

for full pilot holes, while the Infinitas cortical punch

minimizes torque in dense cortical bone.

Digital Innovation

In collaboration with DB Digital’s services, Infinitas

can be uniquely integrated with metal 3D-printed

appliances, including RME expansion and mesial

sliders.

This delivers:

• Clinically precise appliances for improved

outcomes

• No need for separators or molar bands,

enhancing patient comfort

• Reduced chair time for the clinician

5


In collaboration with

DB Digital Solutions offers a range of innovative orthodontic products

and services created by skilled technicians using the latest technology

advancements.

FAST

The use of digital processes cuts down turnaround

times, and so the time between taking the intra-oral

scan and receiving the custom-made appliance is

reduced.

EFFICIENT

Innovative techniques used when designing and

making appliances result in fewer appointments being

needed and less time being spent chairside.

PRECISE

Cutting-edge, digitally designed, and 3D-printed

appliances provide full customisation and high

precision.

COMFORTABLE

Putting patient comfort at the forefront of design, our

3D-printed appliances eliminate the need for bands

and separators.

CONVENIENT

Scans are accepted via various channels,

streamlining case submission for clinicians and

eliminating the need for alginate/silicone impressions.

6


CONNECTING

WITH DB DIGITAL

NO SCANNER? NO PROBLEM

We also accept Impressions!

Ring iTero Customer Service to

add Studio 8

Case type: iRecord

Studio8@dbortho.com

Log in to 3shape

communicate

Send request using

Studio8@dbortho.com

Send to:

Studio8@dbortho.com

Select Studio 8

(DB Orthodontics)

from the laboratory list

Please click here

download the

prescription form

Select Studio 8

(DB Orthodontics)

from the laboratory list

7


Infinitas Stent Guidance System

The Infinitas system combines highly specialised

instruments with a unique 3D guidance delivery

system. Using the guidance stent will give

confidence and peace of mind that the correct

insertion site and angles are achieved.

The stent contains a guide cylinder which

accurately guides all instrumentation to the

prescribed position.

The stent components, available in the Infinitas

Guidance Kit, simplify the production of a 3D stent

and ensure effortless and accurate mini-implant

insertion in any location.

DB Orthodontics offers a stent production service

from an impression or intra-oral scan; whether you

embrace digital or prefer a traditional workflow,

Infinitas fits.

• Provides a reproducible 3D insertion.

• Provides stable insertion point

• (no slippage of implant tip on bone) during

oblique insertion and especially helpful in

difficult to access sites e.g. palate.

• Reduces perforation risks.

• Inspires confidence in implant novices and

difficult

• access insertions.

• Prescribes insertion details for other clinicians.

• Reduces surgery time & stress.

8

Infinitas Mini Implant System Atlas

+44 (0) 1535 656999


Palatal Applications

Palatal mini implant placement requires the use of a specialist

handpiece. The recommended device is the NSK ISD900,

which is lightweight and provides sufficient torque at low

speed. This allows for controlled and precise mini implant

insertion.

The Infinitas system includes three mini inserts (mucotome,

cortical bone punch and screwdriver inserts) Each insert is

designed with a contra-angle latch grip connection, making

them compatible with the NSK ISD900 handpiece or any other

latch grip handpiece of similar design.

Mucotome insert used

when necessary to

remove soft tissue

Cortical bone punch used

when necessary to perforate

dense cortical bone

Screwdriver insert used in

all cases for mini implant

placement

Colour coded Diameter (mm) Body Length (mm) Neck Head Shape Sterile code

1.5 6 Short Standard DB10-0009

1.5 9 Short Standard DB10-0010

1.5 9 Long Standard DB10-0012

2.0 6 Long Standard DB10-0015

2.0 9 Long Standard DB10-0016

1.5 9 Long Round DB10-0018

2.0 6 Long Roiund DB10-0019

sales@dbortho.com www.dbortho.com 9


Intrusion

Sterile I DB10-0004

Non Sterile I DB10-0012

Mini implant position: Palatal alveolar

Appliance Type: Reverse offset Intrusion TPA

Protocol: Single Visit Protocol

Pre-Appointment:

Send Scan or Impression to Lab with Infinitas prescription

Lab requirements:

• Reverse offset intrusion TPA

• Stent(s)

• Thermoformed lower arch retainer

Clinical requirements:

• ISD900 handpiece (or similar)

• Mini Inserts (Mini Screwdriver, Mini Mucotome, Mini

Cortical Bone Punch)

Mini implant and appliance fit:

Place TADs using handpiece & unilateral stents

Fit and cement the intrusion TPA onto the molar teeth

Activation:

Power chain in a V or L formation as shown in fig. 2

Tip! Use a thermoformed retainer in the lower arch to

stabilise lower molars.

Click Here to

Watch Animation

10

Infinitas Mini Implant System Atlas

+44 (0) 1535 656999


Expansion

Sterile I DB10-0008

Non Sterile I DB10-0016

Mini implant position: Mid Palate

Appliance Type: 3D printed RME

Protocol: Single Visit Protocol

Pre-Appointment:

Send Scan or Impression to Lab with Infinitas prescription

Lab requirements:

• 3D Printed RME (Standard or Telescopic)

• Stent(s)

• Clinical validation of mini implant location

Clinical requirements:

• ISD900 handpiece (or similar)

• Mini Inserts (Mini Screwdriver, Mini Mucotome, Mini

Cortical Bone Punch)

• Mini implants

• Guidance stent

Mini implant and appliance fit:

Prepare the insertion site using mucotome and cortical bone

punch through guidance stent (fig. 1)

Fit and cement the appliance onto the molar teeth

Place mini implants using handpiece and guidance stent

(fig. 2)

Activation:

Immediate activation.

Slow expansion. Initially 1 turn per day for < 20 years, 1 turn

on alternate days for 20+ years age. Increase to 2 turns per

day once diastema appears.

Click Here to

Watch Animation

sales@dbortho.com www.dbortho.com 11


Mesialisation

Sterile I DB10-0019

Mini implant position: Mid Palate

Appliance Type: Palatal Clip mesialiser

Protocol: Two Visit Protocol

Appointment One

Clinical requirements:

• ISD900 handpiece (or similar)

• Mini Inserts (Mini Screwdriver, Mini Mucotome, Mini

Cortical Bone Punch)

Mini implant placement

Send Scan or Impression to DB Digital with Infinitas

prescription

Lab requirements:

• Palatal Clip Mesialiser (3D Printed or Traditional)

Appointment Two

Palatal Clip Mesialiser provided in appliance holder

Fit and cement the appliance onto the molar teeth

Use a Weingart plier to crimp the soft wire (‘clip’) around the

mini implant undercut

Activation:

Activate the appliance using elastomeric chain or nickel

titanium springs between the hooks on the appliance

Click Here to

Watch Animation

12

Infinitas Mini Implant System Atlas

+44 (0) 1535 656999


Molar Protraction

Sterile I DB10-0007

Non Sterile I DB10-0015

Mini implant position: Mid Palate

Appliance Type: 3D Printed T Bar

Protocol: Single Visit Protocol

Pre-Appointment:

Send Scan or Impression to Lab with Infinitas prescription

Lab requirements:

• 3D Printed T Bar

• Stent(s)

• Clinical validation of mini implant location

Clinical requirements:

• ISD900 handpiece (or similar)

• Mini Inserts (Mini Screwdriver, Mini Mucotome, Mini

Cortical Bone Punch)

• Mini implants

• Guidance stent

Mini implant and appliance fit:

Prepare the insertion site using mucotome and cortical bone

punch through guidance stent

Fit appliance with holding device

Place mini implants using handpiece and guidance stent

(fig. 2)

Composite the T bar onto the anterior teeth and in the mini

implant head

sales@dbortho.com www.dbortho.com 13


Ryefield Way I Silsden I West Yorkshire I BD20 0EF I United Kingdom

Tel: 01535 656999 E: sales@dbortho.com W: www.dbortho.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!