09.01.2013 Views

Cables for Installations and Industry - Draka

Cables for Installations and Industry - Draka

Cables for Installations and Industry - Draka

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

CONTENTS


INSTALLATION CABLES<br />

– General in<strong>for</strong>mation about cables . . . . . . . . . . . . 3<br />

– Electrical properties. . . . . . . . . . . . . . . . . . . . 4<br />

– Identification of insulated conductors . . . . . . . . . . 5<br />

– Notes <strong>and</strong> symbols . . . . . . . . . . . . . . . . . . . . 6<br />

INSTALLATION CABLES<br />

– ML H07V-U . . . . . . . . . . . . . . . . . . . . . . . 7<br />

– MK 90 H07V2-R . . . . . . . . . . . . . . . . . . . . . 8<br />

MKEM 90 H07V2-K . . . . . . . . . . . . . . . . . . . 10<br />

– MMJ . . . . . . . . . . . . . . . . . . . . . . 12<br />

– MPLM . . . . . . . . . . . . . . . . . . . . . . 14<br />

– MKEMP . . . . . . . . . . . . . . . . . . . . . . 15<br />

– MJAM . . . . . . . . . . . . . . . . . . . . . . 16<br />

– MJAM ARM . . . . . . . . . . . . . . . . . . . . . . 18<br />

POWER CABLES 0,6/1 kV<br />

– MCMK . . . . . . . . . . . . . . . . . . . . . . 20<br />

– MCMK . . . . . . . . . . . . . . . . . . . . . . 22<br />

– AMCMK . . . . . . . . . . . . . . . . . . . . . . 24<br />

– MCCMK . . . . . . . . . . . . . . . . . . . . . . 26<br />

CONTROL CABLES<br />

– MMO . . . . . . . . . . . . . . . . . . . . . . 29<br />

– MCMO . . . . . . . . . . . . . . . . . . . . . . 30<br />

JUMPER WIRES<br />

– MKJE 90 H05V2-U, MKJ 90 H05V2-K,<br />

– MKJT 90 H05V2-K . . . . . . . . . . . . . . . . . . . 32<br />

– MKEMT 90 H07V2-K . . . . . . . . . . . . . . . . . . 35<br />

– MVJ 8 kV . . . . . . . . . . . . . . . . . . . . . . 36<br />

FLEXIBLE CORDS<br />

– MST H03VH-H . . . . . . . . . . . . . . . . . . . . . . 37<br />

– MSO H03VVH2-F . . . . . . . . . . . . . . . . . . . . 38<br />

– MSOY H03VV-F . . . . . . . . . . . . . . . . . . . . . 39<br />

– MSK H05VV-F . . . . . . . . . . . . . . . . . . . . . . 40<br />

INSTRUMENTATION CABLES<br />

– General:<br />

– Data transmission cables. . . . . . . . . . . . . . . . 42<br />

– Electrical properties. . . . . . . . . . . . . . . . . . . 42<br />

– Selection of the cable type . . . . . . . . . . . . . . . 43<br />

– Industrial networks . . . . . . . . . . . . . . . . . . . 44<br />

– Symmetrical halogen-free instrumentation cables . . . 44<br />

– Optical fibre cables in industry . . . . . . . . . . . . . 45<br />

INSTRUMENTATION CABLES<br />

– JAMAK . . . . . . . . . . . . . . . . . . . . . . 46<br />

– JAMAK ARM . . . . . . . . . . . . . . . . . . . . . . 47<br />

– JAMAK-C . . . . . . . . . . . . . . . . . . . . . . 48<br />

– NOMAK . . . . . . . . . . . . . . . . . . . . . . 50<br />

– NOMAK-E . . . . . . . . . . . . . . . . . . . . . . 51<br />

– FKAR-PG . . . . . . . . . . . . . . . . . . . . . . 52<br />

– KLAM . . . . . . . . . . . . . . . . . . . . . . 53<br />

– RD- . . . . . . . . . . . . . . . . . . . . . . 54<br />

– RD-Y(St)Y . . . . . . . . . . . . . . . . . . . . . . 55<br />

– JAMAK & JAMAK ARM JOINTIG . . . . . . . . . . . 56<br />

2<br />

CONTENTS<br />

SIGNAL CABLES<br />

– LON CABLING<br />

– Distributed data system of building technology . . . . . 57<br />

– LONAK 2 x 1,3 <strong>and</strong> LONAK ARM 2 x 1,3 . . . . . . . 58<br />

– LONAK 2 x 2 x 0,8 <strong>and</strong> LONAK 2 x 2 x 0,65. . . . . . 59<br />

– KLM . . . . . . . . . . . . . . . . . . . . . . 60<br />

– KLMA . . . . . . . . . . . . . . . . . . . . . . 61<br />

– MMSA . . . . . . . . . . . . . . . . . . . . . . 62<br />

– MMVDMA (MMPMA) . . . . . . . . . . . . . . . . . . 63<br />

DATA CABLES<br />

– Generic cabling systems<br />

– General . . . . . . . . . . . . . . . . . . . . . . 64<br />

– St<strong>and</strong>ards . . . . . . . . . . . . . . . . . . . . . . 64<br />

– Screening . . . . . . . . . . . . . . . . . . . . . . 64<br />

– Application <strong>and</strong> transmission classes . . . . . . . . . 64<br />

– Recommendations . . . . . . . . . . . . . . . . . . . 64<br />

– Data transmission cables. . . . . . . . . . . . . . . . 64<br />

– Generic cabling construction . . . . . . . . . . . . . . 65<br />

– Atm . . . . . . . . . . . . . . . . . . . . . . 65<br />

– Meaning of the symbols . . . . . . . . . . . . . . . . 65<br />

– Generic cabling cable type . . . . . . . . . . . . . . . 66<br />

– The colour system of the conductors. . . . . . . . . . 66<br />

– Compliance statement . . . . . . . . . . . . . . . . . 67<br />

– UC 300 S 24 4P/ UC 300 DS 24 2 x 4P . . . . . . . . 68<br />

– UC 300 24 4P/ UC 300 D 24 2 x 4P . . . . . . . . . . 70<br />

– UC 400 S 24 4P/ UC 400 DS 24 4P . . . . . . . . . . 72<br />

– UC 400 24 4P/ UC 400 D 24 2 x 4P . . . . . . . . . . 74<br />

– UC 600 SS 23/ 1 4P FRNC <strong>and</strong><br />

UC 1200 SS 22 4P FRNC. . . . . . . . . . . . . . . . 76<br />

– SUPERCAT . . . . . . . . . . . . . . . . . . . . . . 78<br />

FIBRE OPTIC CABLES<br />

FIBRE OPTIC ACCESSORIES<br />

– Fibre optic cables in premises data networks . . . . . . 80<br />

– General<br />

– Type coding of optical fibre cables . . . . . . . . . . . 81<br />

– Colour coding system of optical fibre cables. . . . . . 81<br />

– Optical fiber types . . . . . . . . . . . . . . . . . . . 81<br />

– Different constructions of optical fibre cables . . . . . 82<br />

– Optical fibre cables of NK <strong>Cables</strong> <strong>for</strong> different<br />

applications . . . . . . . . . . . . . . . . . . . . . . 82<br />

– Fymsu-term . . . . . . . . . . . . . . . . . . . . . . 83<br />

– Connectorised riser cables . . . . . . . . . . . . . . . 83<br />

– Distribution panels <strong>and</strong> cabinets . . . . . . . . . . . . 83<br />

– Data <strong>and</strong> instrumentation cable<br />

DATAJAMAK . . . . . . . . . . . . . . . . . . . . . . 84<br />

– Wiring <strong>and</strong> installation cables<br />

KLVMAAM, KLVMAM . . . . . . . . . . . . . . . . . . 86<br />

CATV/ RG CABLES<br />

– TELLU 13 . . . . . . . . . . . . . . . . . . . . . . 87<br />

– RG 58, (50 Ω), RG 59, (75 Ω) . . . . . . . . . . . . . 88<br />

– RG 213, RG 214, RG 223 (50 Ω) . . . . . . . . . . . . 89<br />

CABLE DRUMS<br />

– Maximum length of cable per drum, in meters . . . . . . 90<br />

– Dimensions <strong>and</strong> weights . . . . . . . . . . . . . . . . . 91


GE NE RAL IN FOR MA TI ON ABOUT CAB LES<br />

CATA LOGUE IN FOR MA TION<br />

The di men sions <strong>and</strong> weights are rounded nomi nal<br />

val ues.<br />

The let ters “D” <strong>and</strong> “A” ap pear ing in the prod uct<br />

speci fi ca tions in di cate:<br />

D = nomi nal over all di ame ter<br />

A = ca ble’s to tal cop per cross- section<br />

Bold print ing in di cates an item nor mally kept in stock<br />

AP PLI CA TION<br />

The har moni za tion docu ment HD 516 (Guide to use of<br />

low- voltage har mo nized ca bles) pro vides a guide to<br />

the pro posed safe use of har mo nized elec tric ca bles<br />

ac cord ing to HD 21.<br />

Ca bles should be se lected so that they are suit able <strong>for</strong><br />

the op er at ing con di tions.<br />

Ex am ples of op er at ing con di tions are:<br />

- volt age<br />

- over cur rent<br />

- pro tec tive meas ures<br />

- group ing of ca bles<br />

- method of in stal la tion<br />

- ac ces si bil ity<br />

Ca bles should be se lected so that they are suit able <strong>for</strong> any<br />

ex ter nal in flu ences which may ex ist.<br />

Ex am ples of ex ter nal in flu ences are:<br />

- am bi ent tem pera ture; mini mum <strong>and</strong> maxi mum<br />

- pre cence of rain, steam or ac cu mu la tion of wa ter<br />

- pre cense of cor ro sive, chemi cal or pol lut ing<br />

sub stances<br />

- me chani cal stresses (im pact, ten sion, com pres sion,<br />

sharp edges)<br />

- fauna (such as ro dents)<br />

- flora (such as mould)<br />

- ra dia tion (such as sun light)<br />

LI NYL<br />

Plastic- insulated con duc tors, ML, MK, MKEM <strong>and</strong><br />

plastic- sheated ca bles MMJ as well as plastic- sheated<br />

con trol ca bles MMO are coated with the Li nyl plas tic<br />

com pound. The Li nyl con pound makes the ca ble very slick<br />

<strong>and</strong> nearly fric tion less, <strong>and</strong> thus re quires only<br />

one- fifth of the pull ing <strong>for</strong>ce of an or di nary ca ble when<br />

drawn in ducts. As a re sult of this “fric tion less ness”,<br />

it is no longer nec es sary to use lu bri cants, which can be<br />

det ri men tal to plas tics. In stal la tion is eas ier, faster, lighter<br />

<strong>and</strong> con sid era bly more eco nomi cal <strong>and</strong> re li able.<br />

IN STAL LA TION OF THE CA BLE ON<br />

THE DRUM<br />

In stal la tion of a ca ble onto ca ble drum as well as<br />

wind ing to an other drum must be done in the man ner<br />

de picted be low.<br />

CE SYM BOL<br />

The CE sym bol on ca ble pack ages in di cates<br />

com pli ance with the EU’s low- voltage di rec tive.<br />

STAN DARDS<br />

The ca bles in the cata logue are manu fac tured<br />

ac cord ing to valid Fin nish SFS stan dards or<br />

in ter na tional CENE LEC stan dards.<br />

The in de pend ent <strong>and</strong> con trolled qual ity la bels,<br />

the sym bol <strong>and</strong> the pan- European sym bol,<br />

in di cate that the ca bles have been tested <strong>and</strong> cer ti fied.<br />

ISO 9001 QUAL ITY SYS TEM<br />

The Qual ity Man age ment Sys tem of <strong>Draka</strong> NK Ca bles Ltd<br />

has been ap proved by Lloyd’s Reg is ter Qual ity As sur ance<br />

Ltd to ISO 9001 <strong>and</strong> 14001:1994 Qual ity Man age ment<br />

Sys tem Stan dard.<br />

3


4<br />

RATED VOLT AGE<br />

The rated volt age of ca bles is marked Uo/U, where:<br />

- U o = rated volt age be tween the con duc tor <strong>and</strong> earth<br />

or me tal lic screen<br />

- U = rated volt age be tween con duc tors.<br />

DI RECT CUR RENT RE SIS TANCE OF<br />

CON DUC TORS<br />

The cata logue lists <strong>for</strong> each ca ble, the maxi mum di rect<br />

cur rent re sis tance val ues <strong>for</strong> the con duc tor at<br />

a tem pera ture of +20 °C, per mit ted by the con struc tion<br />

stan dard.The cur rent in a con duc tor heats up<br />

the con duc tor. The rise in tem pera ture in creases<br />

the con duc tor’s re sis tance. The fol low ing ta ble shows<br />

some pre- calculated cor rec tion fac tors <strong>for</strong> the di rect<br />

cur rent re sis tance of cop per con duc tor:<br />

Conductor temperature °C Correction factor<br />

20<br />

40<br />

60<br />

70<br />

80<br />

90<br />

ELECT RI CAL PRO PER TIES<br />

1,0<br />

1,079<br />

1,157<br />

1,196<br />

1,236<br />

1,275<br />

CA BLES CUR RENT CAR RY ING<br />

CA PAC ITY<br />

Cur rent car ry ing ca paci ties of in stal la tion ca bles are given<br />

in HD 384.5.523 (or IEC 364- 5- 523):<br />

Elec tri cal in stal la tion of build ings sec tion 523:<br />

Cur rent car ry ing ca paci ties.<br />

Cur rent rat ing ta bles are based on the re quire ments of<br />

the maxi mum per mis si ble con duc tor tem pera tures in<br />

con tinu ous use <strong>and</strong> as sumed in stal la tion con di tions.<br />

The cor rec tion fac tors must be used when the con di tions<br />

dif fer from the in stal la tion con di tions as sumed in<br />

the cur rent rat ing ta bles.<br />

Cur rent rat ings <strong>for</strong> flexi ble ca bles<br />

(PVC ca bles ac cord ing to HD 21)<br />

HD 516 Ta ble 7a<br />

Cross-section of<br />

conductors<br />

mm 2<br />

0,75<br />

1,0<br />

1,5<br />

2,5<br />

4<br />

Current rating<br />

2 cores load<br />

A<br />

6<br />

10<br />

16<br />

25<br />

32<br />

Current rating<br />

3 cores load<br />

A<br />

As sump tions <strong>for</strong> ta ble are:<br />

- Con duc tor tem pera ture in PVC- insulated ca bles<br />

+70 °C.<br />

- Am bi ent air tem pera ture +30 °C.<br />

Ta ble <strong>for</strong> con trol ca bles.<br />

6<br />

10<br />

16<br />

20<br />

25<br />

The maxi mum per mis si ble con tinu ous<br />

cur rent load in am peres <strong>for</strong> PVC- insulated con trol ca ble<br />

U o /U=450/750 V in stalled in open air.<br />

Number of<br />

conductors with<br />

load<br />

4<br />

7<br />

12<br />

19<br />

27<br />

37<br />

48<br />

Copper conductor cross-section<br />

mm 2<br />

0,75 1,5 2,5<br />

–<br />

8<br />

7<br />

6<br />

5<br />

4<br />

4<br />

As sump tions <strong>for</strong> ta ble are:<br />

- Con duc tor tem pera ture +70 °C<br />

- Am bi ent air tem pera ture +25 °C<br />

–<br />

13<br />

11<br />

9<br />

8<br />

7<br />

6<br />

20<br />

16<br />

13<br />

11<br />

10<br />

9<br />


IDEN TI FI CA TI ON OF IN SU LA TED<br />

CON DUC TORS<br />

PREVIOUS AND NEW STANDARD,<br />

HD 308 S2<br />

MMJ, MJAM <strong>and</strong> MPLM<br />

m<br />

e<br />

t<br />

s<br />

y<br />

s<br />

-<br />

N<br />

m<br />

e<br />

t<br />

s<br />

y<br />

-<br />

S<br />

Previous<br />

2-wires<br />

4-wires<br />

5-wires<br />

3-wires<br />

4-wires<br />

4-wires*<br />

5-wires<br />

MSK, MSO <strong>and</strong> MSOY<br />

m<br />

e<br />

t<br />

s<br />

y<br />

s<br />

-<br />

N<br />

Previous<br />

MCMK <strong>and</strong> MCCMK<br />

m<br />

e<br />

t<br />

s<br />

y<br />

-<br />

S<br />

Previous<br />

Previous<br />

Previous<br />

3-wires<br />

2-wires<br />

3-wires<br />

4-wires<br />

5-wires<br />

3-wires<br />

4-wires<br />

5-wires<br />

HD 308 S2<br />

New<br />

New<br />

*Only <strong>for</strong> 1,5 <strong>and</strong> 2,5 mm 2 cables<br />

HD 308 S2<br />

New<br />

New<br />

HD 308 S2<br />

New<br />

AB BRE VIA TIONS OF COL OURS<br />

AP PEAR ING IN CATA LOGUE<br />

(on drum, reel or coil la bels)<br />

MU = BK Black<br />

SI = BU Blue<br />

KEVI = GNYE Green/yel low<br />

RU = BN Brown<br />

VA = WH White<br />

PU = RD Red<br />

KE = YE Yel low<br />

ORA = OG Or ange<br />

HA = GY Grey<br />

CON TROL CA BLES<br />

Con duc tors in con trol ca bles are of the same col our<br />

(black ) <strong>and</strong> con secu tively num bered start ing from<br />

the centre of the ca ble.<br />

SHEATH MARK INGS<br />

The fol low ing em bossed or col our mark ings are marked<br />

on the outer sheath of in stal la tion, power <strong>and</strong> con trol<br />

ca bles used in fixed in stal la tions<br />

- manu fac tur er’s code<br />

- type des ig na tion, number <strong>and</strong> cross- section of<br />

con duc tors, iden ti fi ca tion let ters of the in su la tion<br />

col ours, <strong>and</strong> rated volt age<br />

- manu fac tur er’s in ter nal code<br />

- con tinu ous me ter mark ing<br />

- SGS FIMKO cer ti fi ca tion mark<br />

Ex am ple:<br />

NK CABLES MMJ 5x2,5 mm 2 S 300/500 V 24AS45<br />

00001<br />

CER TI FI CA TIONS<br />

SGS FIMKO -ce rf ified<br />

HAR -marked<br />

Russian Certification St<strong>and</strong>ard<br />

5


6<br />

N<br />

SYM BOLS<br />

AP PLI CA TION<br />

MAXI MUM TEM PERA TURE<br />

LOW EST TEM PERA TURE<br />

BEND ING RA DIUS<br />

TEN SILE STRESS<br />

VOLT AGE<br />

STAN DARD<br />

CER TI FI CA TIONS<br />

IDEN TI FI CA TION OF CORES<br />

CON STRUC TION<br />

SELF- EXTINGUISHING IEC 332-1<br />

SELF-EXTINGUISHING IEC 332-3<br />

ELEC TRO MAG NETIC COM PATI BIL ITY<br />

HALO GEN FREE<br />

FIRE- RESISTANT IEC 331<br />

NOTE<br />

NOTES AND SYM BOLS<br />

See more info<br />

www.drakankc.fi all these<br />

cables you find in NK Club.<br />

EAN CODE<br />

The EAN number (Euro pean Ar ti cle Num ber) will be<br />

adopted in ad di tion to the na tional elec tri cal ar ti cle<br />

number. It is <strong>for</strong>med from the na tional elec tri cal ar ti cle<br />

number as fol lows:<br />

64 (= Fin l<strong>and</strong>’s coun try code)<br />

100 (= manu fac turer code ap plied <strong>for</strong> by<br />

Fin nish Elec tri cal Whole sal ers’ Fed era tion SSTL)<br />

04 067 22 (= SSTL’s elec tri cal number)<br />

2 (con trol number cal cu lated<br />

ac cord ing to the EAN regu la tion)<br />

Ex am ple. MMJ 3x1,5 S coil 64 100 04 067 22-2


1,5 mm 2<br />

AP PLI CA TION<br />

For fixed in stal la tion in a con duit, <strong>and</strong> <strong>for</strong> wir ing in<br />

ap pli ances, switch gear <strong>and</strong> con trol gear with<br />

a maxi mum volt age of 1000 V (a.c.) or a maxi mum of<br />

750 V (d.c.) to earth.<br />

Cur rent car ry ing ca paci ties ac cord ing to HD 384.5.523<br />

(or IEC 364- 5- 523): “Elec tri cal in stal la tion of build ings”<br />

-se ction 523: Cur rent car ry ing ca paci ties.<br />

Maxi mum per mis si ble tem pera ture of con duc tor:<br />

– in con tinu ous use +70 °C<br />

– in short cir cuit (max. 5 s) +160 °C<br />

Low est rec om mended han dling<br />

tem pera ture: -25 °C<br />

Mini mum rec om mended bend ing ra dius:<br />

– dur ing in stal la tion 8xD<br />

– in a fi nal in stal la tion if bent only once 3xD<br />

INSTALLATION CABLES<br />

Maxi mum per mis si ble ten sile stress<br />

dur ing in stal la tion: Ax50 N/mm²<br />

RATED VOLT AGE<br />

U o /U = 450/750 V<br />

STAN DARD<br />

SFS 5523 <strong>and</strong> CENE LEC HD 21<br />

Cross-section of conductor<br />

<strong>and</strong> colour mm² 1,5 VA 1,5 RU 1,5 MU 1,5 SI 1,5 KEVI<br />

EAN code (SSTL code) 64 100+<br />

coil 04 008 00-3 04 008 02-7 04 008 03-4 04 008 07-2 04 008 08-9<br />

Nominal overall diameter mm 2,7 2,7 2,7 2,7 2,7<br />

Total weight kg/km 20 20 20 20 20<br />

Direct current resistance of<br />

conductorat+20 °C max. Ω/km 12,1 12,1 12,1 12,1 12,1<br />

St<strong>and</strong>ard delivery length m 200 200 200 200 200<br />

2,5 mm 2<br />

CON STRUC TION<br />

Con duc tor An nealed cop per wire<br />

Cross-section of conductor <strong>and</strong><br />

colour mm² 2,5 VA 2,5 RU 2,5 MU 2,5 SI 2,5 KEVI<br />

EAN code (SSTL code) 64 100+<br />

coil 04 008 20-1 04 008 22-5 04 008 23-2 04 008 27-0 04 008 28-7<br />

Nominal overall diameter mm 3,3 3,3 3,3 3,3 3,3<br />

Total weight kg/km 31 31 31 31 31<br />

Direct current resistance of<br />

conductorat+20 °C max. Ω/km 7,41 7,41 7,41 7,41 7,41<br />

St<strong>and</strong>ard delivery length m 200 200 200 200 200<br />

Coil = shrink-wrapped coil<br />

Plas tic- in su la ted con duc tor<br />

ML H07V-U<br />

So lid con duc tor<br />

N<br />

Self- extinguishing IEC 332-1<br />

In su la tion Lead- free Li nyl PVC,<br />

core iden ti fi ca tion by col ours<br />

7


IN STAL LA TION CA BLES<br />

8<br />

N<br />

AP PLI CA TION<br />

For per ma nent in stal la tion in a con duit, <strong>and</strong> <strong>for</strong> wir ing<br />

in ap pli ances, switch gear <strong>and</strong> con trol gear with<br />

a maxi mum volt age of 1000 V (a.c.) or a maxi mum of<br />

750 V (d.c.) to earth.<br />

Plas tic- in su la ted con duc tor<br />

MK 90 H07V2-R<br />

Stran ded con duc tor<br />

Cur rent car ry ing ca paci ties ac cord ing to HD 384.5.523<br />

(or IEC 364- 5- 523): “Elec tri cal in stal la tion of build ings”<br />

-se ction 523: Cur rent car ry ing ca paci ties.<br />

Maxi mum per mis si ble tem pera ture of con duc tor:<br />

- in con tinu ous use +90 °C<br />

- in a short cir cuit (max. 5 s) +160 °C<br />

Low est rec om mended han dling<br />

tem pera ture: -25 °C<br />

Mini mum rec om mended bend ing ra dius:<br />

- dur ing in stal la tion 8xD<br />

- in a fi nal in stal la tion if bent only once 3xD<br />

Maxi mum per mis si ble ten sile stress<br />

dur ing in stal la tion Ax50 N/mm²<br />

CON STRUC TION<br />

RATED VOLT AGE<br />

U o /U = 450/750 V<br />

STAN DARD<br />

SFS 5523 <strong>and</strong> CENE LEC HD 21<br />

Con duc tor An nealed cop per wires, str<strong>and</strong>ed In su la tion Lead-free Li nyl PVC, core iden ti fi ca tion<br />

by col ours<br />

1,5 mm2 2,5 mm2<br />

Cross-section of conductor <strong>and</strong><br />

colour mm² 1,5 RU 1,5 MU 1,5 SI 1,5 KEVI 2,5 RU 2,5 MU 2,5 SI 2,5 KEVI<br />

EAN code (SSTL code) 64 100+<br />

coil 04 017 04-3 04 017 03-6 04 017 05-0 04 017 02-9 04 017 08-1 04 017 07-4 04 017 09-8 04 017 06-7<br />

Nominal overall diameter mm 3,0 3,0 3,0 3,0 3,7 3,7 3,7 3,7<br />

Total weight kg/km 22 22 22 22 35 35 35 35<br />

Direct current resistance of<br />

conductorat+20 °C max. Ω/km 12,1 12,1 12,1 12,1 7,41 7,41 7,41 7,41<br />

St<strong>and</strong>ard delivery length m 250 250 250 250 200 200 200 200<br />

Coil = shrink-wrapped coil<br />

Self- extinguishing IEC 332-1


Cross-section of conductor <strong>and</strong><br />

colour mm² 4 MU 4 SI 4 KEVI 6 RU 6 MU 6 SI 6 KEVI<br />

EAN code (SSTL code) 64 100+ 04 017 11-91 04 017 13-5 04 017 10-4 04 017 16-6 04 017 15-9 04 017 17-3 04 017 14-2<br />

Nominal overall diameter mm 4,2 4,2 4,2 4,8 4,8 4,8 4,8<br />

Total weight kg/km 52 52 52 70 70 70 70<br />

Direct current resistance of<br />

conductorat+20 °C max. Ω/km 4,61 4,61 4,61 3,08 3,08 3,08 3,08<br />

St<strong>and</strong>ard delivery length<br />

coil m 150 150 150 100 100 100 100<br />

Cross-section of conductor <strong>and</strong><br />

colour mm² 10 MU 10 SI 10 KEVI 16 MU 16 SI 16 KEVI<br />

EAN code (SSTL code) 64 100+ 04 017 19-5 04 017 20-3 04 017 18-0 04 017 22-7 04 017 23-4 04 017 21-0<br />

Nominal overall diameter mm 6,1 6,1 6,1 7,2 7,2 7,2<br />

Total weight kg/km 115 115 115 175 175 175<br />

Direct current resistance of<br />

conductorat+20 °C max. Ω/km 1,83 1,83 1,83 1,15 1,15 1,15<br />

St<strong>and</strong>ard delivery length<br />

coil m 100 100 100 100 100 100<br />

Cross-section of conductor <strong>and</strong><br />

colour mm² 25 MU 25 SI 25 KEVI 35 MU 35 SI 35 KEVI<br />

EAN code (SSTL code) 64 100+ 04 022 14-6 04 022 15-3 04 022 16-0 04 522 22-6 04 522 23-3 04 522 27-1<br />

Nominal overall diameter mm 8,9 8,9 8,9 10,0 10,0 10,0<br />

Total weight kg/km 270 270 270 370 370 370<br />

Direct current resistance of<br />

conductorat+20 °C max. Ω/km 0,727 0,727 0,727 0,524 0,524 0,524<br />

St<strong>and</strong>ard delivery length<br />

coil m<br />

drum m<br />

100 100 100<br />

500/6C 500/6C 500/6C<br />

Cross-section of conductor <strong>and</strong><br />

colour mm² 50 MU 50 SI 50 KEVI 70 KEVI 95 KEVI 120 KEVI<br />

EAN code (SSTL code) 64 100+ 04 522 33-2 04 522 37-0 04 522 38-7 04 022 48-6 04 022 58-0 04 022 66-5<br />

Nominal overall diameter mm 11,7 11,7 11,7 13,4 16,0 18<br />

Total weight kg/km 510 510 510 710 1000 1200<br />

Direct current resistance of<br />

conductorat+20 °C max. Ω/km 0,387 0,387 0,387 0,268 0,193 0,153<br />

St<strong>and</strong>ard delivery length<br />

drum m 200/6C 200/6C 200/6C 200/6C 500/8E 800/11G<br />

Coil = shrink-wrapped coil<br />

Plas tic- in su la ted con duc tor<br />

MK90 H07V2-R<br />

Stran ded con duc tor<br />

INSTALLATION CABLES<br />

9


INSTALLATION CABLES<br />

10<br />

N<br />

AP PLI CA TION<br />

For fixed in stal la tion in a con duit, <strong>and</strong> <strong>for</strong> wir ing in<br />

ap pli ances, switch gear <strong>and</strong> con trol gear with<br />

a maxi mum volt age of 1000 V (a.c.) or a maxi mum of<br />

750 V (d.c.) to earth.<br />

Plas tic- in su la ted con duc tor<br />

MKEM 90 H07V2-K<br />

Fle xib le con duc tor<br />

Cur rent car ry ing ca paci ties ac cord ing to HD 384.5.523<br />

(or IEC 364- 5- 523): “Elec tri cal in stal la tion of build ings”<br />

-se ction 523: Cur rent car ry ing ca paci ties.<br />

Maxi mum per mis si ble tem pera ture of con duc tor:<br />

- in con tinu ous use +90 °C<br />

- in a short cir cuit (max. 5 s) +160 °C<br />

Low est rec om mended han dling<br />

tem pera ture: – 25 °C<br />

Mini mum rec om mended bend ing ra dius:<br />

- dur ing in stal la tion 8xD<br />

- in a fi nal in stal la tion if bent only once 3xD<br />

Maxi mum per mis si ble ten sile stress<br />

dur ing in stal la tion Ax50 N/mm²<br />

CON STRUC TION<br />

Con duc tor An nealed cop per wires, str<strong>and</strong>ed<br />

flexi ble<br />

RATED VOLT AGE<br />

U o /U = 450/750 V<br />

STAN DARD<br />

SFS 5523 <strong>and</strong> CENE LEC HD 21<br />

Self- extinguishing IEC 332-1<br />

In su la tion Lead-free Li nyl PVC, core iden ti fi ca tion<br />

by col ours<br />

Cross-section of conductor <strong>and</strong><br />

colour mm² 1,5 RU 1,5 MU 1,5 SI 1,5 KEVI 2,5 RU 2,5 MU 2,5 SI 2,5 KEVI<br />

EAN code (SSTL code) 64 100+ 04 031 02-5 04 031 03-2 04 031 07-0 04 031 08-7 04 031 22-3 04 031 23-0 04 031 27-8 04 031 28-5<br />

Nominal overall diameter mm 3,0 3,0 3,0 3,0 3,6 3,6 3,6 3,6<br />

Total weight kg/km 21 21 21 21 32 32 32 32<br />

Direct current resistance of<br />

conductor at+20 °C max. Ω/km 13,3 13,3 13,3 13,3 7,98 7,98 7,98 7,98<br />

St<strong>and</strong>ard delivery length<br />

coil m 250 250 250 250 200 200 200 200


Plas tic- in su la ted con duc tor<br />

MKEM 90 H07V2-K<br />

Fle xib le con duc tor<br />

Cross-section of conductor <strong>and</strong><br />

colour mm² 4 MU 4 SI 4 KEVI 6 MU 6 SI 6 KEVI<br />

EAN code (SSTL code) 64 100+ 04 031 43-8 04 031 47-6 04 031 48-3 04 031 63-6 04 031 67-4 04 031 68-1<br />

Nominal overall diameter mm 4,1 4,1 4,1 5,0 5,0 5,0<br />

Total weight kg/km 45 45 45 70 70 70<br />

Direct current resistance of<br />

conductorat+20 °C max. Ω/km 4,95 4,95 4,95 3,30 3,30 3,30<br />

St<strong>and</strong>ard delivery length , coil m 100 100 100 100 100 100<br />

Cross-section of conductor <strong>and</strong><br />

colour mm² 10 MU 10 SI 10 KEVI 16 MU 16 SI 16 KEVI<br />

EAN code (SSTL code) 64 100+ 04 031 83-4 04 031 87-2 04 031 88-9 04 032 03-9 04 032 07-7 04 032 08-4<br />

Nominal overall diameter mm 6,5 6,5 6,5 7,6 7,6 7,6<br />

Total weight kg/km 115 115 115 170 170 170<br />

Direct current resistance of<br />

conductorat+20 °C max. Ω/km 1,91 1,91 1,91 1,21 1,21 1,21<br />

St<strong>and</strong>ard delivery length, coil m 100 100 100 100 100 100<br />

Cross-section of conductor <strong>and</strong><br />

colour mm² 25 MU 25 SI 25 KEVI 35 MU 35 SI 35 KEVI<br />

EAN code (SSTL code) 64 100+ 04 032 13-8 04 032 17-6 04 032 18-3 04 532 23-2 04 532 27-0 04 532 28-7<br />

Nominal overall diameter mm 9,4 9,4 9,4 11,0 11,0 11,0<br />

Total weight kg/km 270 270 270 370 370 370<br />

Direct current resistance of<br />

conductorat+20 °C max. Ω/km 0,780 0,780 0,780 0,554 0,554 0,554<br />

St<strong>and</strong>ard delivery length<br />

coil m<br />

drum m<br />

100 100 100<br />

INSTALLATION CABLES<br />

500/6C 500/6C 500/6C<br />

Cross-section of conductor <strong>and</strong><br />

colour mm² 50 MU 50 SI 50 KEVI 70 MU 70 SI 70 KEVI<br />

EAN code (SSTL code) 64 100+ 04 532 33-1 04 532 37-9 04 532 38-6 04 532 43-0 04 532 47-8 04 532 48-5<br />

Nominal overall diameter mm 13,0 13,0 13,0 13,0 15,0 15,0<br />

Total weight kg/km 520 520 520 730 730 730<br />

Direct current resistance of<br />

conductorat+20 °C max. Ω/km 0,386 0,386 0,386 0,272 0,272 0,272<br />

St<strong>and</strong>ard delivery length, drum m 200/6C 200/6C 200/6C 200/6C 200/6C 200/6C<br />

Cross-section of conductor <strong>and</strong><br />

colour mm² 95 MU 95 SI 120 MU 150 MU 240 MU<br />

EAN code (SSTL code) 64 100+ 04 032 53-4 04 032 57-2 04 032 63-3 04 032 73-2 04 032 93-0<br />

Nominal overall diameter mm 17,5 17,5 19 22 27<br />

Total weight kg/km 940 940 1200 1450 2400<br />

Direct current resistance of<br />

conductorat+20 °C max. Ω/km 0,206 0,206 0,161 0,129 0,0801<br />

St<strong>and</strong>ard delivery length, drum m 200/7E 200/7E 200/7E 200/7E 450/11G<br />

11


INSTALLATION CABLES<br />

12<br />

N<br />

AP PLI CA TION<br />

For fixed sur face or flush- mounted in stal la tions,<br />

in doors <strong>and</strong> out doors.<br />

- Suit able <strong>for</strong> in stal la tion in a slot cov ered with plas ter<br />

- Not <strong>for</strong> in stal la tion di rectly in ground nor di rectly in<br />

con crete with out pro tec tive duct ing.<br />

- Not <strong>for</strong> in stal la tions sub ject to elec tri cal in ter fer ence<br />

(see MCCMK <strong>and</strong> MJAM).<br />

- Di rect sun light may change col our of sheath<br />

Cur rent car ry ing ca paci ties ac cord ing to HD 384.5.523<br />

(or IEC 364- 5- 523): “Elec tri cal in stal la tion of build ings”<br />

-se ction 523: Cur rent car ry ing ca paci ties.<br />

Maxi mum per mis si ble tem pera ture of con duc tor:<br />

- in con tinu ous use +70 °C<br />

- in a short cir cuit (max. 5 s) +160 °C<br />

Low est rec om mended han dling<br />

tem pera ture: -15 °C<br />

Mini mum rec om mended bend ing ra dius:<br />

- dur ing in stal la tion 10xD<br />

- in a fi nal in stal la tion if bent only once 3xD<br />

Maxi mum per mis si ble ten sile stress<br />

dur ing in stal la tion Ax50 N/mm²<br />

CON STRUC TION<br />

Con duc tor An nealed cop per 1,5 <strong>and</strong> 2,5 mm², solid<br />

6...25 mm², str<strong>and</strong>ed<br />

In su la tion Lead free PVC, core iden ti fi ca tion by col ours<br />

Plas tic- sheat hed cab le<br />

MMJ<br />

RATED VOLT AGE<br />

U o /U = 300/500 V, 1,5 mm² <strong>and</strong> 2,5 mm²<br />

U o /U = 450/750 V, 6 mm² ... 25 mm²<br />

STAN DARD<br />

SFS 2091 <strong>and</strong> SFS 5524<br />

CORE IDEN TI FI CA TION<br />

WITH PROTECTIVE CONDUCTOR<br />

Number of conductors <strong>and</strong><br />

cross-section nxmm² 3 x 1,5 S 3 x 2,5 S 3 x 6 S 3 x 10 S<br />

EAN code (SSTL code)<br />

(coil) 64 100+<br />

(reel) 64 100+<br />

(drum) 64 100+<br />

04 067 22-2<br />

04 567 72-2<br />

04 567 22-7<br />

04 067 23-9<br />

04 567 73-9<br />

04 567 23-4<br />

04 067 25-3<br />

–<br />

04 567 25-8<br />

–<br />

–<br />

04 067 26-0<br />

Nominal overall diameter mm 8,8 10,0 14,1 17,1<br />

Total weight kg/km 130 180 350 540<br />

Direct current resistance of<br />

conductor at +20 °C.max. Ω/km 12,1 7,41 3,08 1,83<br />

St<strong>and</strong>ard delivery length<br />

coil m<br />

reel m<br />

drum m<br />

100<br />

300<br />

1000/K7<br />

2-wires<br />

3-wires<br />

4-wires<br />

5-wires<br />

100<br />

200<br />

1000/K7<br />

N-system<br />

Self- extinguishing IEC 332-1<br />

Fill ing Fill ing com pound<br />

Sheath White, lead free Li nyl PVC<br />

- marked by me ters<br />

50<br />

–<br />

500/K8<br />

3-wires<br />

4-wires<br />

4-wires*<br />

5-wires<br />

S-ystem<br />

*Only <strong>for</strong> 1,5 <strong>and</strong> 2,5 mm 2 cables<br />

–<br />

–<br />

400/K8


WITH PROTECTIVE CONDUCTOR<br />

Number of conductors <strong>and</strong><br />

cross-section nxmm² 4 x 1,5 S 4 x 2,5 S 4 x 6 S 4 x 10 S 4 x 16 S<br />

EAN code (SSTL code)<br />

(coil) 64 100+<br />

(reel) 64 100+<br />

(drum) 64 100+<br />

04 067 32-1<br />

04 567 82-1<br />

04 567 32-6<br />

04 067 33-8<br />

–<br />

04 567 33-3<br />

–<br />

–<br />

04 567 35-7<br />

–<br />

–<br />

04 067 36-4<br />

–<br />

–<br />

04 567 37-1<br />

Nominal overall diameter mm 9,6 11,0 15,3 18,8 21,0<br />

Total weight kg/km 155 220 430 670 940<br />

Direct current resistance of<br />

conductor at +20 °C.max. Ω/km 12,1 7,41 3,08 1,83 1,15<br />

St<strong>and</strong>ard delivery length<br />

coil m<br />

reel m<br />

drum m<br />

100<br />

250<br />

1000/K7<br />

100<br />

–<br />

750/K7<br />

–<br />

–<br />

500/K8<br />

WITH PROTECTIVE CONDUCTOR<br />

–<br />

–<br />

400/K8<br />

–<br />

–<br />

250/K8<br />

Number of conductors <strong>and</strong><br />

cross-section nxmm² 5 x 1,5 S 5 x 2,5 S 5 x 6 S 5 x 10 S 5 x 16 S 5 x 25 S<br />

EAN code (SSTL code)<br />

(coil) 64 100+<br />

(reel) 64 100+<br />

(drum) 64 100+<br />

04 067 42-0<br />

04 567 92-0<br />

04 567 42-5<br />

04 067 43-7<br />

04 567 93-7<br />

04 567 43-2<br />

–<br />

–<br />

04 567 45-6<br />

–<br />

–<br />

04 067 46-8<br />

–<br />

–<br />

04 067 47-5<br />

–<br />

–<br />

04 067 48-2<br />

Nominal overall diameter mm 10,3 11,8 16,6 21,0 23,0 31,0<br />

Total weight kg/km 180 260 510 830 1200 1900<br />

Direct current resistance of<br />

conductor at +20 °C.max. Ω/km 12,1 7,41 3,08 1,83 1,15 0,727<br />

St<strong>and</strong>ard delivery length<br />

coil m<br />

reel m<br />

drum m<br />

100<br />

200<br />

1000/K7<br />

50<br />

150<br />

750/K8<br />

–<br />

–<br />

500/K8<br />

–<br />

–<br />

250/K8<br />

WITHOUT PROTECTIVE CONDUCTOR<br />

–<br />

–<br />

250/K9<br />

–<br />

–<br />

250/K11<br />

Number of conductors <strong>and</strong><br />

cross-section nxmm² 2 x 1,5 N 2 x 2,5 N 3 x 1,5 N 4 x 1,5 N 5 x 1,5 N<br />

EAN code (SSTL code)<br />

(coil) 64 100+<br />

(drum) 64 100+<br />

04 064 12-2<br />

04 564-12-7<br />

04 064 13-9<br />

04 564 13-4<br />

04 064 22-1<br />

04 564 22-6<br />

04 064 32-0<br />

04 564 32-5<br />

04 064 42-9<br />

04 564 42-4<br />

Nominal overall diameter mm 8,4 9,6 8,8 9,6 10,3<br />

Total weight kg/km 105 150 130 155 180<br />

Direct current resistance of<br />

conductor at +20 °C.max. Ω/km 12,1 7,41 12,1 12,1 12,1<br />

St<strong>and</strong>ard delivery length<br />

coil m<br />

drum m<br />

100<br />

1000/K7<br />

Plas tic- sheat hed cab le<br />

MMJ<br />

100<br />

1000/K7<br />

100<br />

1000/K7<br />

INSTALLATION CABLES<br />

100<br />

1000/K7<br />

100<br />

1000/K7<br />

13


INSTALLATION CABLES<br />

14<br />

N<br />

AP PLI CA TION<br />

For fixed sur face in stal la tion in doors.<br />

Cur rent car ry ing ca paci ties ac cord ing to HD 384.5.523<br />

(or IEC 364- 5- 523): “Elec tri cal in stal la tion of build ings”<br />

-se ction 523: Cur rent car ry ing ca paci ties.<br />

Maxi mum per mis si ble tem pera ture of con duc tor:<br />

- in con tinu ous use +70 °C<br />

- in a short cir cuit (max. 5 s) +160 °C<br />

Low est rec om mended han dling<br />

tem pera ture: –15 °C<br />

Mini mum rec om mended bend ing ra dius:<br />

- dur ing in stal la tion 10xD<br />

- in a fi nal in stal la tion if bent only once 3xD<br />

Maxi mum per mis si ble ten sile stress<br />

dur ing in stal la tion Ax50 N/mm²<br />

CON STRUC TION<br />

Con duc tor An nealed cop per wire<br />

In su la tion PVC, core iden ti fi ca tion by col ours<br />

Fill ing Fill ing com pound<br />

Surfa ce instal la ti on cab le NOT KA<br />

MPLM<br />

WITH PROTECTIVE CONDUCTOR<br />

RATED VOLT AGE<br />

U o /U = 300/500 V<br />

STAN DARD<br />

SS 424 02 19-2<br />

CORE IDEN TI FI CA TION<br />

Self- extinguishing IEC 332-1<br />

Drain wire Tinned copper wires<br />

Metal sheath Lon gi tu di nal alu min ium tape<br />

Sheath White PVC<br />

WITHOUT<br />

PROTECTIVE<br />

CONDUCTOR<br />

Number of conductors <strong>and</strong><br />

cross-section nxmm² 3 x 1,5/1 S 3 x 2,5/1 S 4 x 1,5/1 S 5 x 1,5/1 S 2 x 1,5/1 N 3 x 1,5/1 N<br />

EAN code (SSTL code) 64 100+ 04 055 26-7 04 055 27-4 04 055 36-6 04 055 46-5 04 055 11-3 04 055 23-6<br />

Nominal overall diameter mm 8,5 9,8 9,2 10,0 8,0 8,5<br />

Total weight kg/km 130 185 165 185 110 130<br />

Direct current resistance of<br />

conductor at +20 °C.max. Ω/km 12,1 7,41 12,1 12,1 12,1 12,1<br />

St<strong>and</strong>ard delivery length<br />

coil m 50 50 50 50 50 50<br />

2-wires<br />

3-wires<br />

N-system S-ystem<br />

3-wires<br />

4-wires<br />

5-wires


N<br />

AP PLI CA TION<br />

For fixed in stal la tion mainly as a con nect ing ca ble <strong>for</strong><br />

post mounted lu mi naires.<br />

Maxi mum per mis si ble tem pera ture of con duc tor:<br />

- in con tinu ous use +70 °C<br />

- in a short cir cuit (max. 5 s) +160 °C<br />

Low est rec om mended<br />

han dling tem pera ture: -25 °C<br />

Mini mum rec om mended bend ing ra dius:<br />

- dur ing ca ble pull ing 10xD<br />

- in a fi nal in stal la tion if bent only once 3xD<br />

Maxi mum per mis si ble ten sile stress: Ax50 N/mm²<br />

CON STRUC TION<br />

Con duc tor An nealed cop per wires,<br />

str<strong>and</strong>ed flexi ble<br />

In su la tion PVC<br />

Cab le <strong>for</strong> lamp- posts<br />

MKEMP<br />

Fle xib le con duc tor<br />

RATED VOLT AGE<br />

U o /U = 450/750 V<br />

STAN DARDI<br />

SFS 5523 <strong>and</strong> SFS 2091<br />

Self- extinguishing IEC 332-1<br />

Sheath PVC<br />

INSTALLATION CABLES<br />

Cross-section of conductors<br />

<strong>and</strong> colour mm² 2,5 MU 2,5 SI 2,5 KEVI<br />

EAN code (SSTL code) 64 100+ 04 034 03-3 04 034 07-1 04 034 08-8<br />

Nominal overall diameter mm 8,0 8,0 8,0<br />

Total weight kg/km 82 82 82<br />

Direct current resistance of<br />

conductor at +20 °C max. Ω/km 7,98 7,98 7,98<br />

St<strong>and</strong>ard delivery length<br />

coil m 100 100 100<br />

15


INSTALLATION CABLES<br />

16<br />

N<br />

AP PLI CA TION<br />

Ca ble <strong>for</strong> the con trol, meas ur ing <strong>and</strong> sig nal cir cuits of<br />

elec tri cal equip ment <strong>and</strong> feeder ca ble <strong>for</strong> elec tronic<br />

equip ment <strong>for</strong> fixed sur face <strong>and</strong> flush- mounted<br />

in stal la tions, in doors <strong>and</strong> out doors.<br />

The lapped Al- PE lami nate <strong>for</strong>ms a good screen against<br />

elec tri cal in ter fer ence <strong>and</strong> the lami nate<br />

com bined with the PE- sheath <strong>for</strong>ms a good mois ture<br />

bar rier.<br />

Cur rent car ry ing ca paci ties ac cord ing to HD 384.5.523<br />

(or IEC 364- 5- 523): “Elec tri cal in stal la tion of build ings”<br />

-se ction 523: Cur rent car ry ing ca paci ties.<br />

Maxi mum per mis si ble tem pera ture of con duc tor:<br />

- in con tinu ous use +70 °C<br />

- in a short cir cuit (max. 5 s) +160 °C<br />

Low est rec om mended<br />

han dling tem pera ture: –15 °C<br />

Mini mum rec om mended bend ing ra dius:<br />

- dur ing in stal la tion 12xD<br />

- in a fi nal in stal la tion if bent only once 8xD<br />

Maxi mum per mis si ble ten sile stress<br />

dur ing in stal la tion Ax50 N/mm²<br />

Me tal sheat hed cab le<br />

MJAM<br />

3-wires<br />

4-wires<br />

4-wires*<br />

5-wires<br />

RATED VOLT AGE<br />

U o /U = 450/750 V<br />

STAN DARD<br />

SS 4240219<br />

CORE IDEN TI FI CA TION<br />

S-ystem<br />

*Only <strong>for</strong> 1,5 <strong>and</strong> 2,5 mm 2 cables<br />

Control cables 7...19 wires; numbers<br />

Self- extinguishing IEC 332-1<br />

Elec tro mag netic com pati bil ity


CON STRUC TION<br />

Con duc tor An nealed cop per:<br />

1,5 <strong>and</strong> 2,5 mm 2 solid<br />

6 <strong>and</strong> 10 mm 2 str<strong>and</strong>ed<br />

In su la tion Lead free PVC, core iden ti fi ca tion by<br />

col ours <strong>and</strong>/or num bers<br />

WITH PROTECTIVE CONDUCTOR<br />

Number of conductors <strong>and</strong><br />

cross-section nxmm² 3 x 1,5 S 3 x 2,5 S 3 x 6 S<br />

EAN code (SSTL code) 64 100+ 04 130 01-8 04 130 02-5 04 130 04-9<br />

Nominal overall diameter mm 10 11,5 15<br />

Total weight kg/km 145 200 360<br />

Direct current resistance of<br />

conductor at +20 °C.max. Ω/km 12,1 7,41 3,08<br />

St<strong>and</strong>ard delivery length<br />

drum m 500/K6 500/K7 250/K8<br />

WITH PROTECTIVE CONDUCTOR<br />

Number of conductors <strong>and</strong><br />

cross-section nxmm² 5 x 1,5 S 5 x 2,5 S 5 x 6 S<br />

EAN code (SSTL code) 64 100+ 04 130 07-0 04 130 08-7 04 130 10-0<br />

Nominal overall diameter mm 11,5 13 18<br />

Total weight kg/km 200 280 520<br />

Direct current resistance of<br />

conductor at +20 °C.max. Ω/km 12,1 7,41 3,08<br />

St<strong>and</strong>ard delivery length<br />

drum m 500/K7 500/K7 250/K8<br />

WITHOUT PROTECTIVE CONDUCTOR<br />

Number of conductors <strong>and</strong><br />

cross-section nxmm² 7 x 1,5 12 x 1,5 19 x 1,5<br />

EAN code (SSTL code) 64 100+ 04 130 15-5 04 130 18-6 04 130 20-9<br />

Nominal overall diameter mm 12,5 16 19<br />

Total weight kg/km 250 380 550<br />

Direct current resistance of<br />

conductor at +20 °C.max. Ω/km 12,1 12,1 12,1<br />

St<strong>and</strong>ard delivery length<br />

drum m 400/K7 400/K8 400/K9<br />

Electrical properties<br />

Capacitance between<br />

two adjacent conductors<br />

at +20 °C <strong>and</strong> 50 Hz nF/km<br />

Capacity to earth of<br />

one conductor<br />

at +20 °C <strong>and</strong> 50 Hz nF/km<br />

130...160<br />

210...280<br />

Me tal sheat hed cab le<br />

MJAM<br />

130...160<br />

210...280<br />

INSTALLATION CABLES<br />

Fill ing Fill ing com pound<br />

Me tal lic screen AI- PE lami nate <strong>and</strong> drain wire,<br />

1,0 mm²<br />

Sheath White PE/lead free PVC<br />

- marked by me ters<br />

130...160<br />

210...280<br />

17


INSTALLATION CABLES<br />

18<br />

N<br />

AP PLI CA TION<br />

Ca ble <strong>for</strong> the con trol, meas ur ing <strong>and</strong> sig nal cir cuits of<br />

elec tri cal equip ment <strong>and</strong> feeder ca ble <strong>for</strong> elec tronic<br />

equip ment <strong>for</strong> fixed sur face <strong>and</strong> flush- mounted<br />

in stal la tions, in doors <strong>and</strong> out doors.<br />

The ar mour ing <strong>and</strong> the lapped AI- PE lami nate <strong>for</strong>ms<br />

a good me chani cal, elec tri cal <strong>and</strong> elec tro mag neti cal<br />

shield <strong>for</strong> the ca ble, <strong>and</strong> the lami nate com bined with the<br />

PE- sheath <strong>for</strong>ms a good mois ture bar rier.<br />

Cur rent car ry ing ca paci ties ac cord ing to HD 384.5.523<br />

(or IEC 364- 5- 523): “Elec tri cal in stal la tion of build ings”<br />

-se ction 523: Cur rent car ry ing ca paci ties.<br />

Maxi mum per mis si ble tem pera ture of con duc tor:<br />

- in con tinu ous use +70 °C<br />

- in a short cir cuit (max. 5 s) +160 °C<br />

Low est rec om mended<br />

han dling tem pera ture: -15 °C<br />

Mini mum rec om mended bend ing ra dius:<br />

- dur ing in stal la tion 12xD<br />

- in a fi nal in stal la tion if bent only once 8xD<br />

Maxi mum per mis si ble ten sile stress<br />

dur ing in stal la tion Ax50 N/mm²<br />

Ar mou red me tal- sheat hed cab le<br />

MJAMARM<br />

3-wires<br />

4-wires<br />

4-wires*<br />

5-wires<br />

RATED VOLT AGE<br />

U o /U = 450/750 V<br />

STAN DARD<br />

SFS 5247 <strong>and</strong> SS 4240219<br />

CORE IDEN TI FI CA TION<br />

S-ystem<br />

*Only <strong>for</strong> 1,5 <strong>and</strong> 2,5 mm 2 cables<br />

Control cables 7...19 wires; numbers<br />

Self- extinguishing IEC 332-1<br />

Elec tro mag netic com pati bil ity


CON STRUC TION<br />

Con duc tor An nealed cop per:<br />

1,5 <strong>and</strong> 2,5 mm 2 solid<br />

6 <strong>and</strong> 10 mm 2 str<strong>and</strong>ed<br />

In su la tion Lead free PVC, core iden ti fi ca tion by<br />

col ours <strong>and</strong>/or num bers<br />

Fill ing Fill ing com pound<br />

WITH PROTECTIVE CONDUCTORS<br />

Number of conductors <strong>and</strong><br />

cross-section nxmm² 3 x 1,5 S 3 x 2,5 S<br />

EAN code (SSTL code) 64 100+ 04 130 51-3 04 130 52-0<br />

Nominal overall diameter mm 13 15<br />

Total weight kg/km 290 360<br />

Direct current resistance of<br />

conductor at +20 °C.max. Ω/km 12,1 7,41<br />

St<strong>and</strong>ard delivery length<br />

drum m 300/6C 300/7E<br />

WITH PROTECTIVE CONDUCTORS<br />

Number of conductors <strong>and</strong><br />

cross-section nxmm² 5 x 1,5 S 5 x 2,5 S<br />

EAN code (SSTL code) 64 100+ 04 130 57-5 04 130 58-2<br />

Nominal overall diameter mm 15 17<br />

Total weight kg/km 360 460<br />

Direct current resistance of<br />

conductor at +20 °C.max. Ω/km 12,1 7,41<br />

St<strong>and</strong>ard delivery length<br />

drum m 300/7E 300/8E<br />

WITHOUT PROTECTIVE CONDUCTORS<br />

Number of conductors <strong>and</strong><br />

cross-section nxmm² 7 x 1,5 7 x 2,5 12 x 1,5 19 x 1,5<br />

EAN code (SSTL code) 64 100+ 04 130 65-0 04 130 66-7 04 130 68-1 04 130 70-4<br />

Nominal overall diameter mm 16 18 20 23<br />

Total weight kg/km 430 560 610 820<br />

Direct current resistance of<br />

conductor at +20 °C.max. Ω/km 12,1 7,41 12,1 12,1<br />

St<strong>and</strong>ard delivery length<br />

drum m 400/8E 400/9E 400/11G 400/11G<br />

Electrical properties<br />

Capacitance between<br />

two adjacent conductors<br />

at +20 °C <strong>and</strong> 50 Hz nF/km<br />

Capacity to earth of<br />

one conductor<br />

at +20 °C <strong>and</strong> 50 Hz nF/km<br />

Ar mou red me tal- sheat hed cab le<br />

MJAMARM<br />

130...160<br />

210...280<br />

130...160<br />

220...290<br />

INSTALLATION CABLES<br />

Me tal lic screen AI- PE lami nate <strong>and</strong><br />

drain wire, 1,0 mm²<br />

Sheath White PE/lead free PVC<br />

Ar mour ing Two zinc- coated steel tapes<br />

Sheath Black lead free PVC<br />

- marked by me ters<br />

130...160<br />

210...280<br />

130...160<br />

210...280<br />

19


POWER INSTALLATION CABLES<br />

20<br />

N<br />

AP PLI CA TION<br />

For fixed in stal la tion in doors, out doors <strong>and</strong><br />

un der ground as well as in build ing struc tures,<br />

e.g. di rectly in con crete.<br />

Not <strong>for</strong> in stal la tions sub ject to se vere elec tri cal<br />

in ter fer ence (see MCCMK <strong>and</strong> MJAM).<br />

Cur rent car ry ing ca paci ties ac cord ing to HD 384.5.523<br />

(or IEC 364- 5- 523): “Elec tri cal in stal la tion of build ings”<br />

-se ction 523: Cur rent car ry ing ca paci ties.<br />

Maxi mum per mis si ble tem pera ture of con duc tor:<br />

- in con tinu ous use +70 °C<br />

- in a short cir cuit (max. 5 s) +160 °C<br />

Low est rec om mended<br />

han dling tem pera ture: –15 °C<br />

Mini mum rec om mended bend ing ra dius:<br />

- dur ing in stal la tion 12xD<br />

- in a fi nal in stal la tion if bent only once 8xD<br />

Maxi mum per mis si ble ten sile stress<br />

dur ing in stal la tion Ax50 N/mm²<br />

Elec tro mag netic com pati bil ity<br />

MCMK<br />

2-wires<br />

3-wires<br />

4-wires<br />

RATED VOLT AGE<br />

U o /U = 0,6/1 kV U m = 1,2 kV<br />

STAN DARD<br />

SFS 4880, HD 603-3F S1, IEC 60502-1<br />

CORE IDEN TI FI CA TION<br />

Self- extinguishing IEC 332-1


CON STRUC TION<br />

Con duc tor An nealed cop per<br />

1,5 ... 6 mm², solid<br />

10 <strong>and</strong> 16 mm² , str<strong>and</strong>ed<br />

In su la tion Lead free PVC, core iden ti fi ca tion by<br />

col ours <strong>and</strong>/or num bers<br />

Fill ing Fill ing com pound<br />

Number of conductors <strong>and</strong><br />

cross-section nxmm² 2 x 1,5/1,5 2 x 1,5/1,5 2 x 2,5/2,5 2 x 2,5/2,5 2 x 6/6 2 x 10/10 RM<br />

EAN code (SSTL code) 64 100+ 06 021 12-3 06 021 22-2 06 021 13-0 06 021 23-9 06 021 25-3 06 021 26-0<br />

Nominal overall diameter mm 11,5 11,5 12,3 12,3 16,2 19,0<br />

Total weight kg/km 165 165 200 200 370 550<br />

Direct current resistance of<br />

conductor at +20 °C.max. Ω/km 12,1 12,1 7,41 7,41 3,08 1,83<br />

St<strong>and</strong>ard delivery length<br />

coil m<br />

drum m<br />

100<br />

1000/8E<br />

100<br />

1000/K9 500/K8 500/K9<br />

Number of conductors <strong>and</strong><br />

cross-section nxmm² 3 x 1,5/1,5 3 x 2,5/2,5 3 x 6/6 3 x 10/10 RM 3 x 16/16 RM<br />

EAN code (SSTL code) 64 100+ 06 021 52-9 06 021 53-6 06 021 55-0 06 021 56-7 06 021 57-4<br />

Nominal overall diameter mm 12 13 17 20,0 23,0<br />

Total weight kg/km 190 240 450 680 970<br />

Direct current resistance of<br />

conductor at +20 °C.max. Ω/km 12,1 7,41 3,08 1,83 1,15<br />

St<strong>and</strong>ard delivery length<br />

drum m 1000/K8 1000/K9 500/K8 500/K9 500/K11<br />

Number of conductors <strong>and</strong><br />

cross-section nxmm² 4 x 1,5/1,5 4 x 1,5/1,5 4 x 2,5/2,5 4 x 2,5/2,5 4 x 6/6 4 x 10/10 RM 4 x 16/16 RM<br />

EAN code (SSTL code) 64 100+ 06 021 92-5 06 021 72-7 06 021 93-2 06 021 43-7 06 021 45-1 06 021 76-5 06 021 47-5<br />

Nominal overall diameter mm 13 13 14 14 18,5 22 25<br />

Total weight kg/km 210 210 270 270 520 790 1150<br />

Direct current resistance of<br />

conductor at +20 °C.max. Ω/km 12,1 12,1 7,41 7,41 3,08 1,83 1,15<br />

St<strong>and</strong>ard delivery length<br />

coil m<br />

drum m<br />

100<br />

MCMK<br />

1000/K9<br />

100<br />

POWER INSTALLATION CABLES<br />

Con cen tric<br />

con duc tor A layer of cop per wires <strong>and</strong> an open<br />

he lix of par al lel cop per wires<br />

Sheath Black, lead free PVC<br />

- marked by me ters<br />

1000/K9 500/K9 500/K11 500/K11<br />

21


POWER INSTALLATION CABLES<br />

22<br />

N<br />

AP PLI CA TION<br />

For fixed in stal la tion in doors, out doors <strong>and</strong><br />

un der ground as well as in build ing struc tures,<br />

e.g. di rectly in con crete.<br />

Not <strong>for</strong> in stal la tions sub ject to se vere elec tri cal<br />

in ter fer ence (see MCCMK).<br />

Cur rent car ry ing ca paci ties ac cord ing to HD 384.5.523<br />

(or IEC 364- 5- 523): “Elec tri cal in stal la tion of build ings”<br />

-se ction 523: Cur rent car ry ing ca paci ties.<br />

Maxi mum per mis si ble tem pera ture of con duc tor:<br />

- in con tinu ous use +70 °C<br />

- in a short cir cuit (max. 5 s) +160 °C<br />

Low est rec om mended<br />

han dling tem pera ture: –15 °C<br />

Mini mum rec om mended bend ing ra dius:<br />

- dur ing in stal la tion 12xD<br />

- in a fi nal in stal la tion if bent only once 8xD<br />

Maxi mum per mis si ble ten sile stress<br />

dur ing in stal la tion Ax50 N/mm²<br />

MCMK 1kV<br />

RATED VOLT AGE<br />

U o /U = 0,6/1 kV U m = 1,2 kV<br />

STAN DARD<br />

SFS 4880, HD 603-3F S1, IEC 60502-1,<br />

IEC 60332-3<br />

CORE IDEN TI FI CA TION<br />

3-wires<br />

4-wires<br />

Self- extinguishing IEC 332-3


MCMK 3½<br />

Number of conductors <strong>and</strong><br />

cross-section nxmm² 3 x 25/16 AN 1kV 3 x 35/16 AN 1kV 3 x 50/25 AN 1kV 3 x 70/35 AN 1kV 3 x 95/50 AN 1kV<br />

EAN code (SSTL code) 64 100+ 06 001 30-9 06 001 31-6 06 001 32-3 06 001 33-3 06 001 34-7<br />

Nominal overall diameter mm 25 27 28 32 36<br />

Total weight kg/km 1450 1800 2100 2700 3600<br />

St<strong>and</strong>ard delivery length m 500 500 500 500 500<br />

St<strong>and</strong>ard delivery drum K11 K12 K12 K14 K16<br />

Weight (gable + drum) kg 780 1000 1150 1470 2000<br />

MCMK 3½<br />

Number of conductors <strong>and</strong><br />

cross-section nxmm² 3 x 120/70 AN 1kV 3 x 150/70 AN 1kV 3 x 185/95 AN 1kV 3 x 240/120 AN 1kV<br />

EAN code (SSTL code) 64 100+ 06 001 35-4 06 001 36-1 06 001 37-8 06 001 38-5<br />

Nominal overall diameter mm 40 43 48 54<br />

Total weight kg/km 4500 5500 6750 9000<br />

St<strong>and</strong>ard delivery length m 500 500 500 500<br />

St<strong>and</strong>ard delivery drum K18 K18 K20 K22<br />

Weight (gable + drum) kg 2500 3000 3750 4950<br />

MCMK 4½<br />

Number of conductors <strong>and</strong><br />

cross-section nxmm² 4 x 25/16 AN 1kV 4 x 35/16 AN 1kV 4 x 50/25 AN 1kV 4 x 70/35 AN 1kV 4 x 95/50 AN 1kV<br />

EAN code (SSTL code) 64 100+ 06 001 40-8 06 001 41-5 06 001 42-2 06 001 43-9 06 001 44-6<br />

Nominal overall diameter mm 28 30 33 35 41<br />

Total weight kg/km 1750 2200 2650 3400 4650<br />

St<strong>and</strong>ard delivery length m 500 500 500 500 500<br />

St<strong>and</strong>ard delivery drum K12 K12 K14 K16 K18<br />

Weight (gable + drum) kg 970 1200 1450 1900 2550<br />

MCMK 4½<br />

CON STRUC TION<br />

Con duc tor Compacted, an nealed (AN), cop per<br />

conductor 25 <strong>and</strong> 35 mm²,<br />

round 50 mm² <strong>and</strong> larger , sector<br />

shaped<br />

Installation Lead-free PVC, core identification<br />

by colours<br />

MCMK 1kV<br />

POWER INSTALLATION CABLES<br />

Laying up Three phase conductors<br />

<strong>and</strong> neutral str<strong>and</strong>ed together<br />

PE/PEN-conductor A layer of cop per wires <strong>and</strong> an<br />

open he lix of cop per tape<br />

Sheath Black, lead free PVC compound<br />

Number of conductors <strong>and</strong><br />

cross-section nxmm² 4 x 120/70 AN 1kV 4 x 150/70 AN 1kV 4 x 185/95 AN 1kV 4 x 240/120 AN 1kV<br />

EAN code (SSTL code) 64 100+ 06 001 45-3 06 001 46-0 06 001 47-7 06 001 48-4<br />

Nominal overall diameter mm 44 49 55 59<br />

Total weight kg/km 5700 7000 8700 11500<br />

St<strong>and</strong>ard delivery length m 500 500 500 500<br />

St<strong>and</strong>ard delivery drum K20 K22 K22 K24<br />

Weight (gable + drum) kg 3200 4900 4800 6200<br />

23


POWER INSTALLATION CABLES<br />

24<br />

N<br />

AP PLI CA TION<br />

For fixed in stal la tion in doors, out doors <strong>and</strong><br />

un der ground installation.<br />

Maxi mum per mis si ble tem pera ture of con duc tor:<br />

- in con tinu ous use +70 °C<br />

- in a short cir cuit (max. 5 s) +160 °C<br />

Low est rec om mended<br />

han dling tem pera ture: –15 °C<br />

Mini mum rec om mended bend ing ra dius:<br />

- dur ing in stal la tion 12xD<br />

- in a fi nal in stal la tion if bent only once 8xD<br />

Maxi mum per mis si ble ten sile stress<br />

dur ing in stal la tion<br />

AMCMK 1 kV<br />

RATED VOLT AGE<br />

U o /U = 0,6/1 kV U m = 1,2 kV<br />

STAN DARD<br />

SFS 4880, HD 603-3F S1, IEC 60502-1,<br />

IEC 60332-3B<br />

CORE IDEN TI FI CA TION<br />

3-wires<br />

4-wires<br />

Self- extinguishing IEC 332-1<br />

Self- extinguishing IEC 332-3


CON STRUC TION<br />

Con duc tor Compacted, an nealed (AN), aluminium<br />

conductor 25 <strong>and</strong> 35 mm²,<br />

round 50 mm² <strong>and</strong> larger , sector<br />

shaped<br />

Installation Lead-free PVC, core identification<br />

by colours<br />

AMCMK 3½<br />

AMCMK 1 kV<br />

Laying up Three phase conductors <strong>and</strong><br />

neutral str<strong>and</strong>ed together<br />

PE/PEN-conductor A layer of cop per wires <strong>and</strong> an<br />

open he lix of cop per tape<br />

Sheath Black, lead free PVC compound<br />

Number of conductors <strong>and</strong><br />

cross-section nxmm² 3 x16/10 AN 1kV 3 x 35/10 AN 1kV 3 x 70/21 AN 1kV<br />

EAN code (SSTL code) 64 100+ 06 225 57-6 06 003 31-0 06 003 33-4<br />

Nominal overall diameter mm 22 27 32<br />

Total weight kg/km 600 1100 1400<br />

St<strong>and</strong>ard delivery length m 1000 500 500<br />

St<strong>and</strong>ard delivery drum K14 K12 K14<br />

Weight (gable + drum) kg 720 650 820<br />

AMCMK 3½<br />

Number of conductors <strong>and</strong><br />

cross-section nxmm² 3 x 120/41 AN 1kV 3 x 185/57 AN 1kV 3 x 240/72 AN 1kV<br />

EAN code (SSTL code) 64 100+ 06 003 35-8 06 003 37-2 06 003 38-9<br />

Nominal overall diameter mm 40 47 53<br />

Total weight kg/km 2100 3000 3900<br />

St<strong>and</strong>ard delivery length m 500 500 500<br />

St<strong>and</strong>ard delivery drum K16 K20 K22<br />

Weight (gable + drum) kg 1250 1850 2350<br />

AMCMK 4½<br />

POWER INSTALLATION CABLES<br />

Number of conductors <strong>and</strong><br />

cross-section nxmm² 4 x 16/10 AN 1kV 4 x 35/16 AN 1kV 4 x 50/15 AN 1kV 4 x 70/21 AN 1kV 4 x 95/29 AN 1kV<br />

EAN code (SSTL code) 64 100+ 06 225 77-4 06 003 41-9 06 003 42-6 06 003 43-3 06 003 44-0<br />

Nominal overall diameter mm 23 31 32 36 41<br />

Total weight kg/km 680 1300 1400 1800 2400<br />

St<strong>and</strong>ard delivery length m 1000 500 500 500 500<br />

St<strong>and</strong>ard delivery drum K14 K14 K14 K16 K18<br />

Weight (gable + drum) kg 800 800 850 1100 1450<br />

AMCMK 4½<br />

Number of conductors <strong>and</strong><br />

cross-section nxmm² 4 x 120/41 AN 1kV 4 x 150/41 AN 1kV 4 x 185/57 AN 1kV 4 x 240/72 AN 1kV 4 x 300/88 AN 1kV<br />

EAN code (SSTL code) 64 100+ 06 003 45-7 06 003 46-04 06 003 47-1 06 003 48-8 06 003 49-5<br />

Nominal overall diameter mm 44 49 53 60 68<br />

Total weight kg/km 2600 3100 3800 4850 6050<br />

St<strong>and</strong>ard delivery length m 500 500 500 500 250<br />

St<strong>and</strong>ard delivery drum K20 K20 K22 K24 K22<br />

Weight (gable + drum) kg 1650 1900 2300 2900 1950<br />

25


INTERFERENCE- PROTECTED 1 kV CA BLES<br />

26<br />

AP PLI CA TION<br />

Fixed indoor, outdoor <strong>and</strong> underground installation<br />

where EMC-properties are required<br />

The EU di rec tive 89/336/EEC on elec tro mag netic<br />

com pati bil ity (EMC) be came ef fec tive on 1st Jan 1996.<br />

The EMC di rec tive to elec tri cal equip ment <strong>and</strong> sys tems.<br />

The equip ment <strong>and</strong> sys tems tar geted in the di rec tive<br />

must be con structed so that their elec tro mag netic<br />

emis sion does not ex ceed a level that would af fect<br />

the proper op era tion of ra dio, tele com mu ni ca tions,<br />

medi cal equip ment, <strong>and</strong> other de vices. The equip ment<br />

must be im mune to in ter fer ence so it can op er ate as<br />

in tended.<br />

Screen ing is es sen tial in en vi ron ments where high<br />

fre quency dis tur bance cur rents <strong>and</strong> fields ex ist.<br />

Such en vi ron ments in clude in dus trial fa cili ties util is ing<br />

fre quency trans <strong>for</strong>mer drives. The in ter fer ing<br />

fre quen cies pro duced by these drives can rise to<br />

hun dreds of mega hertz. There <strong>for</strong>e, the im por tance of<br />

the ca ble’s trans fer im ped ance grows de ci sively.<br />

The smaller the ca ble’s trans fer im ped ance at high<br />

fre quen cies, the bet ter the ca ble’s screen ing abili ties.<br />

Cur rent car ry ing ca paci ties ac cord ing to HD 384.5.523<br />

(or IEC 364- 5- 523): “Elec tri cal in stal la tion of build ings”<br />

-se ction 523: Cur rent car ry ing ca paci ties.<br />

Maxi mum per mis si ble tem pera ture of con duc tor:<br />

- in con tinu ous use +70 °C<br />

- in a short cir cuit (max. 5 s) +160 °C<br />

MCCMK<br />

N<br />

Low est rec om mended<br />

han dling tem pera ture: -15 °C<br />

Mini mum rec om mended bend ing ra dius:<br />

- dur ing in stal la tion 12xD<br />

- in a fi nal in stal la tion if bent only once 8xD<br />

Maxi mum per mis si ble ten sile stress<br />

dur ing in stal la tion Ax50 N/mm²<br />

RATED VOLT AGE<br />

U o /U = 0,6/1 kV<br />

STAN DARD<br />

SFS 4880, HD 603-3F S1, IEC 60502-1<br />

CORE IDEN TI FI CA TION<br />

3-wires<br />

4-wires<br />

Self- extinguishing IEC 332-1


CON STRUC TION<br />

Con duc tor An nealed cop per<br />

2,5 <strong>and</strong> 6 mm² solid<br />

10 <strong>and</strong> 16 mm² str<strong>and</strong>ed<br />

In su la tion Lead- free PVC, core iden ti fi ca tion by<br />

num bers<br />

INTERFERENCE- PROTECTED 1 kV CA BLES<br />

MCCMK<br />

Number of conductors <strong>and</strong><br />

cross-section nxmm² 3 x 2,5/2,5 3 x 6/6 3 x 10/10 RM<br />

3 x 16/16 RM<br />

EAN code (SSTL code) 64 100+ 06 020 53-9 06 020 55-3 06 020 56-0 06 020 57-7<br />

Nominal overall diameter mm 14 18 21 24<br />

Total weight kg/km 260 470 700 1050<br />

Direct current resistance of<br />

conductor at +20 °C.max. Ω/km 7,41 3,08 1,83 1,15<br />

Bending radius m 0,16 0,22 0,25 0,3<br />

St<strong>and</strong>ard delivery length<br />

drum m 1000/K9 1000/K11 1000/K12 1000/15G<br />

Number of conductors <strong>and</strong><br />

cross-section nxmm² 4 x 2,5/2,5 4 x 6/6 4 x 10/10 RM<br />

Fill ing Fill ing com pound<br />

Con cen tric<br />

con duc tor A layer of cop per wires, cop per foil <strong>and</strong><br />

an open he lix of par al lel cop per wires<br />

Sheath Black, lead- free PVC<br />

- marked by me ters<br />

4 x 16/16 RM<br />

EAN code (SSTL code) 64 100+ 06 020 73-7 06 020 75-1 06 020 76-8 06 020 77-5<br />

Nominal overall diameter mm 14,5 19 22 25<br />

Total weight kg/km 290 540 830 1200<br />

Direct current resistance of<br />

conductor at +20 °C.max. Ω/km 7,41 3,08 1,83 1,15<br />

Bending radius m 0,18 0,23 0,27 0,3<br />

St<strong>and</strong>ard delivery length<br />

drum m 1000/K9 1000/K11 1000/13G 1000/15G<br />

27


N<br />

AP PLI CA TION<br />

Ca ble <strong>for</strong> the con trol, meas ur ing <strong>and</strong> sig nal cir cuits<br />

of elec tri cal equip ment <strong>for</strong> fixed sur face <strong>and</strong><br />

flush- mounted in stal la tions, in doors <strong>and</strong> out doors.<br />

Di rect sun light may change col our of sheath.<br />

Maxi mum per mis si ble tem pera ture of con duc tor:<br />

- in con tinu ous use +70 °C<br />

- in a short cir cuit (max. 5 s) +160 °C<br />

Low est rec om mended<br />

han dling tem pera ture: -15 °C<br />

Mini mum rec om mended<br />

bend ing ra dius:<br />

- dur ing in stal la tion 10xD<br />

- in a fi nal in stal la tion if bent only once 8xD<br />

Maxi mum per mis si ble ten sile stress<br />

dur ing in stal la tion : Ax50 N/mm²<br />

CON STRUC TION<br />

Con duc tor An nealed cop per wire<br />

In su la tion Black lead free PVC,<br />

core iden ti fi ca tion by num bers<br />

Plas tic- sheat hed cont rol cab le<br />

MMO<br />

RATED VOLT AGE<br />

U o /U = 450/750 V<br />

STAN DARD<br />

SFS 3714<br />

Self- extinguishing IEC 332-1<br />

Sheath White lead free Li nyl PVC<br />

- marked by me ters<br />

CON TROL CA BLES<br />

Number of conductors <strong>and</strong><br />

cross-section nxmm² 7 x 1,5 12 x 1,5 19 x 1,5 27 x 1,5 37 x 1,5 7 x 2,5 12 x 2,5 19 x 2,5<br />

EAN code (SSTL code) 64 100+ 04 120 22-4 04 120 23-1 04 120 24-8 04 120 25-5 04 120 26-2 04 120 33-0 04 120 34-7 04 120 35-4<br />

Nominal overall diameter mm 12 15 18 21 24 14 18 21<br />

Total weight kg/km 230 350 500 700 950 310 500 750<br />

Direct current resistance of<br />

conductor at +20 °C max. Ω/km 12,1 12,1 12,1 12,1 12,1 7,41 7,41 7,41<br />

St<strong>and</strong>ard delivery length<br />

drum m 1000/8E 500/8E 500/8E 500/11G 500/11G 500/8E 500/8E 500/11G<br />

Electrical properties<br />

Capacitance between two<br />

adjacent conductors<br />

at +20 °C <strong>and</strong> 50 Hz nF/km 120...150 120...150 120...150 120...150 120...150 120...150 120...150 120...150<br />

29


CON TROL CA BLES<br />

30<br />

N<br />

AP PLI CA TION<br />

Ca ble <strong>for</strong> the con trol, meas ur ing <strong>and</strong> sig nal cir cuits<br />

of elec tri cal equip ment <strong>for</strong> fixed sur face <strong>and</strong><br />

flush- mounted in stal la tions, in doors <strong>and</strong> out doors.<br />

The con cen tric cop per con duc tor <strong>for</strong>ms a good<br />

elec tro me chani cal pro tec tion <strong>and</strong> a mod er ate<br />

pro tec tion against elec tri cal in ter fer ence.<br />

Maxi mum per mis si ble tem pera ture of con duc tor:<br />

- in con tinu ous use +70 °C<br />

- in a short cir cuit (max. 5 s) +160 °C<br />

Low est rec om mended han dling<br />

tem pera ture: -15 °C<br />

Mini mum rec om mended bend ing ra dius:<br />

- dur ing in stal la tion 10xD<br />

- in a fi nal in stal la tion if bent only once 8xD<br />

Maxi mum per mis si ble ten sile stress<br />

dur ing in stal la tion Ax50 N/mm²<br />

Elec tro mag netic com pati bil ity<br />

Plas tic- sheat hed cont rol cab le<br />

MCMO<br />

with con cent ric cop per con duc tor<br />

RATED VOLT AGE<br />

U o /U = 450/750 V<br />

STAN DARD<br />

SFS 3713<br />

Self- extinguishing IEC 332-1


CON STRUC TION<br />

Con duc tor An nealed cop per wire<br />

In su la tion Black lead free PVC,<br />

core iden ti fi ca tion by num bers<br />

Fill ing Fill ing com pound<br />

Number of conductors <strong>and</strong><br />

cross-section nxmm² 7 x 1,5 12 x 1,5 19 x 1,5 27 x 1,5 37 x 1,5<br />

EAN code (SSTL code) 64 100+ 06 019 01-4 06 019 02-1 06 019 03-8 06 019 04-5 06 019 05-2<br />

Nominal overall diameter mm 15 19 22 26 28<br />

Total weight kg/km 350 500 680 950 1200<br />

Direct current resistance of<br />

conductor at +20 °C max.<br />

conductor’s Ω/km<br />

concentric conductor Ω/km<br />

12,1<br />

3,08<br />

12,1<br />

3,08<br />

St<strong>and</strong>ard delivery length<br />

drum m 500/8E 400/8E 500/11G 500/11G 400/11G<br />

Electrical properties<br />

Capacitance between two<br />

adjacent conductors<br />

at +20 °C <strong>and</strong> 50 Hz nF/km<br />

Capacity to earth of one<br />

conductor at +20 °C <strong>and</strong> 50 Hz nF/km<br />

130...160<br />

200...270<br />

130...160<br />

200...270<br />

12,1<br />

3,08<br />

130...160<br />

200...270<br />

12,1<br />

3,08<br />

130...160<br />

200...270<br />

12,1<br />

2,60<br />

130...160<br />

200...270<br />

Number of conductors <strong>and</strong><br />

cross-section nxmm² 7 x 2,5 12 x 2,5 19 x 2,5 27 x 2,5 37 x 2,5<br />

EAN code (SSTL code) 64 100+ 06 019 21-2 06 019 22-9 06 019 23-6 06 019 24-3 06 019 25-0<br />

Nominal overall diameter mm 18 21 25 29 32<br />

Total weight kg/km 480 690 950 1350 1700<br />

Direct current resistance of<br />

conductor at +20 °C max.<br />

conductor’s Ω/km<br />

concentric conductor Ω/km<br />

7,41<br />

3,08<br />

7,41<br />

3,08<br />

St<strong>and</strong>ard delivery length<br />

drum m 500/8E 500/11G 500/11G 400/11G 300/11G<br />

Electrical properties<br />

Capacitance between two<br />

adjacent conductors<br />

at +20 °C <strong>and</strong> 50 Hz nF/km<br />

Capacity to earth of one<br />

conductor at +20 °C <strong>and</strong> 50 Hz nF/km<br />

130...160<br />

210...280<br />

Plas tic- sheat hed cont rol cab le<br />

MCMO<br />

with con cent ric cop per con duc tor<br />

130...160<br />

210...280<br />

7,41<br />

3,08<br />

130...160<br />

210...280<br />

7,41<br />

2,60<br />

130...160<br />

210...280<br />

CON TROL CA BLES<br />

Con cen tric<br />

con duc tor A layer of cop per wires <strong>and</strong> an open<br />

he lix of par al lel cop per wires<br />

Sheath Black lead free PVC<br />

7,41<br />

2,60<br />

130...160<br />

210...280<br />

31


JUMPER WIRES<br />

32<br />

Plas tic- in su la ted jum per wi res<br />

MKJE 90 H05V2-U, MKJ 90 H05V2-K,<br />

MKJT 90 H05V2-K<br />

AP PLI CA TION<br />

For per ma nent in stal la tion as in te rior ca bling in light ing<br />

<strong>and</strong> other equip ment.<br />

Maxi mum per mis si ble tem pera ture of con duc tor:<br />

- in con tinu ous use +90 °C<br />

- in a short cir cuit (max. 5 s) +160 °C<br />

Low est rec om mended han dling<br />

tem pera ture: +5 °C<br />

Mini mum rec om mended bend ing ra dius:<br />

- in a fi nal in stal la tion if bent only once 2xD<br />

MKJE 90 H05V2-U<br />

MKJ 90 H05V2-K<br />

MKJT 90 H05V2-K<br />

RATED VOLT AGE<br />

U o /U = 300/500 V<br />

STAN DARD<br />

SFS 5527 = CENE LEC HD 21<br />

H05V2-U (MKJE 90)<br />

H05V2-K (MKJ 90, MKJT 90)<br />

Self- extinguishing IEC 332-1


CON STRUC TION<br />

Con duc tor MKJE 90 annealed cop per wire,<br />

solid<br />

MKJ 90 an nealed c opper wires,<br />

str<strong>and</strong>ed flexible<br />

MKJT 90 tinned, an nealed c opper<br />

wires, str<strong>and</strong>ed flexible<br />

Cross-section of conductors<br />

<strong>and</strong> colour mm²<br />

MKJE 90<br />

H05V2-U<br />

0,75 VA<br />

MKJE 90<br />

H05V2-U<br />

0,75 RU<br />

MKJE 90<br />

H05V2-U<br />

0,75 MU<br />

MKJE 90<br />

H05V2-U<br />

0,75 SI<br />

EAN code (SSTL code) 64 100+ 04 162 20-0 04 162 22-4 04 156 03-2 04 156 07-0<br />

Nominal overall diameter mm 2,2 2,2 2,2 2,2<br />

Total weight kg/km 11 11 11 11<br />

Direct current resistance of<br />

conductor at +20 °C max. Ω/km 24,5 24,5 24,5 24,5<br />

St<strong>and</strong>ard delivery length<br />

spool m 500 500 500 500<br />

Cross-section of conductors<br />

<strong>and</strong> colour mm²<br />

MKJ 90<br />

H05V2-K<br />

0,75 VA<br />

MKJ 90<br />

H05V2-K<br />

0,75 RU<br />

MKJ 90<br />

H05V2-K<br />

0,75 MU<br />

MKJ 90<br />

H05V2-K<br />

0,75 PU<br />

MKJ 90<br />

H05V2-K<br />

0,75 SI<br />

EAN code (SSTL code) 64 100+ 04 156 50-6 04 162 02-6 04 156 53-7 04 162 26-4 04 156 57-5<br />

Nominal overall diameter mm 2,3 2,3 2,3 2,3 2,3<br />

Total weight kg/km 11 11 11 11 11<br />

Direct current resistance of<br />

conductor at +20 °C max. Ω/km 26,0 26,0 26,0 26,0 26,0<br />

St<strong>and</strong>ard delivery length<br />

spool m 500 500 500 500 500<br />

Cross-section of conductors<br />

<strong>and</strong> colour mm²<br />

MKJ 90<br />

H05V2-K<br />

0,75 SI<br />

MKJ 90<br />

H05V2-K<br />

0,75 KEVI<br />

MKJT 90<br />

H05V2-K<br />

0,75 SI<br />

MKJT 90<br />

H05V2-K<br />

0,75 MU<br />

EAN code (SSTL code) 64 100+ 04 162 07-1 04 156 58-2 04 161 07-4 04 156 73-5<br />

Nominal overall diameter mm 2,3 2,3 2,3 2,3<br />

Total weight kg/km 11 11 11 11<br />

Direct current resistance of<br />

conductor at +20 °C max. Ω/km 26,0 26,0 26,7 26,7<br />

St<strong>and</strong>ard delivery length<br />

spool m 500 500 500 500<br />

JUMPER WIRES<br />

Plas tic- in su la ted jum per wi res<br />

MKJE 90 H05V2-U, MKJ 90 H05V2-K,<br />

MKJT 90 H05V2-K<br />

In su la tion PVC, core iden ti fi ca tion by colours<br />

33


JUMPER WIRES<br />

34


AP PLI CA TION<br />

For fixed in stal la tion in a con duit, <strong>and</strong> <strong>for</strong> wir ing in<br />

ap pli ances, switch gear <strong>and</strong> con trol gear with<br />

a maxi mum volt age of 1000 V (a.c.) or a maxi mum of<br />

750 V (d.c.) to earth.<br />

Maxi mum per mis si ble tem pera ture of con duc tor:<br />

- in con tinu ous use +90 °C<br />

- in a short cir cuit (max. 5 s) +160 °C<br />

Low est rec om mended<br />

han dling tem pera ture: -25 °C<br />

Mini mum rec om mended<br />

bend ing ra dius:<br />

- dur ing in stal la tion 8xD<br />

- in a fi nal in stal la tion if bent only once 3xD<br />

CON STRUC TION<br />

Con duc tor Tinned, an nealed cop per wires,<br />

str<strong>and</strong>ed flexi ble<br />

Plas tic- in su la ted jum per wire<br />

MKEMT 90 H07V2-K<br />

Tin ned, fle xib le con duc tor<br />

RATED VOLT AGE<br />

U o /U = 450/750 V<br />

STAN DARD<br />

SFS 5523 <strong>and</strong> CENE LEC HD 21<br />

Self- extinguishing IEC 332-1<br />

JUMPER WIRES<br />

In su la tion Lead-free Li nyl PVC, core iden ti fi ca tion<br />

by col ours<br />

Cross-section of conductors<br />

<strong>and</strong> colour mm² 1,5 MU 1,5 SI 1,5 KEVI 2,5 MU 2,5 SI 2,5 KEVI<br />

EAN code (SSTL code) 64 100+ 04 031 53-7 04 031 57-5 04 031 58-2 04 031 73-5 04 031 77-3 04 031 78-0<br />

Nominal overall diameter mm 3,1 3,1 3,1 3,7 3,7 3,7<br />

Total weight kg/km 21 21 21 32 32 32<br />

Direct current resistance of<br />

conductor at +20 °C max. Ω/km 13,7 13,7 13,7 8,21 8,21 8,21<br />

St<strong>and</strong>ard delivery length<br />

spool m 250 250 250 200 200 200<br />

35


JUMPER WIRES<br />

36<br />

AP PLI CA TION<br />

For fixed in stal la tion in neon lu mi naires.<br />

Maxi mum per mis si ble tem pera ture of con duc tor:<br />

- in con tinu ous use +70 °C<br />

- in a short cir cuit (max. 5 s) +160 °C<br />

Low est rec om mended<br />

han dling tem pera ture: -15 °C<br />

Mini mum rec om mended<br />

bend ing ra dius:<br />

- dur ing in stal la tion 8xD<br />

- in a fi nal in stal la tion if bent only once 4xD<br />

CON STRUC TION<br />

Con duc tor An nealed cop per wires,<br />

str<strong>and</strong>ed flexi ble<br />

Plas tic- in su la ted con duc tor<br />

MVJ 8 kV<br />

Fle xib le con duc tor<br />

RATED VOLT AGE<br />

U o /U = 8/8 kV<br />

STAN DARD<br />

SFS 5680<br />

Cross-section of conductors<br />

<strong>and</strong> colour mm² 1,5 KE<br />

EAN code (SSTL code) 64 100+ 04 201 03-9<br />

Nominal overall diameter mm 6,7<br />

Total weight kg/km 56<br />

Direct current resistance of<br />

conductor at +20 °C max. Ω/km 13,3<br />

St<strong>and</strong>ard delivery length<br />

coil m 100<br />

Self- extinguishing IEC 332-1<br />

In su la tion PVC, yel low


AP PLI CA TION<br />

Non- sheat hed, flat, fle xib le, plas tic- in su la ted cord<br />

MST H03VH-H<br />

Cord <strong>for</strong> very light duty use <strong>for</strong> light port able ap pli ences<br />

in do mes tic prem ises, kitch ens <strong>and</strong> of fices.<br />

- Not <strong>for</strong> kitchen or heat ing ap pli ances<br />

- Not <strong>for</strong> out door use, in dus trial use, ag ri cul tural use or<br />

<strong>for</strong> port able tools<br />

- Not <strong>for</strong> sus pend ing light ing fix tures<br />

Maxi mum per mis si ble tem pera ture of con duc tor:<br />

- in con tinu ous use +40 °C<br />

- in a short cir cuit (max. 5 s) +150 °C<br />

Low est rec om mended<br />

han dling tem pera ture: +5 °C<br />

Mini mum rec om mended<br />

bend ing ra dius:<br />

- in nor mal us age 6xD<br />

CON STRUC TION<br />

Con duc tor An nealed cop per wires,<br />

str<strong>and</strong>ed flexi ble<br />

In su la tion PVC cov er ing two par al lel con duc tors<br />

RATED VOLT AGE<br />

U o /U = 300/300 V<br />

STAN DARD<br />

SFS 5525 = CENE LEC HD 21<br />

H03VH-H<br />

Self- extinguishing IEC 332-1<br />

Iden ti fi ca tion<br />

of con duc tors A lon gi tu di nal ridge on the sur face of<br />

in su la tion on one of the con duc tor’s<br />

Number <strong>and</strong> cross-section of conductors<br />

<strong>and</strong> insulation colour nxmm² 2 x 0,75 VA 2 x 0,75 HA 2 x 0,75 KIR 2 x 0,75 MU<br />

EAN code (SSTL code) 64 100+ 04 171 20-2 04 171 21-9 04 171 28-8 04 171 23-3<br />

Nominal overall diameter mm 2,8x5,6 2,8x5,6 2,8x5,6 2,8x5,6<br />

Total weight kg/km 26 26 26 26<br />

Direct current resistance of<br />

conductor at +20 °C max. Ω/km 26,0 26,0 26,0 26,0<br />

St<strong>and</strong>ard delivery length<br />

spool m 200 200 200 200<br />

FLEXI BLE CORDS<br />

37


FLEXI BLE CORDS<br />

38<br />

N<br />

AP PLI CA TION<br />

Cord <strong>for</strong> light duty use <strong>for</strong> port able ap pli ences in<br />

do mes tic prem ises, kitch ens <strong>and</strong> of fices.<br />

- Not <strong>for</strong> kitchen or heat ing ap pli ances<br />

- Not <strong>for</strong> out door use, in dus trial use, ag ri cul tural use or<br />

<strong>for</strong> non do mes tic port able tools<br />

The weight of the light ing fix ture hang ing from the ca ble<br />

must not ex ceed 2 kg.<br />

Maxi mum per mis si bletem pera ture of con duc tor:<br />

- in con tinu ous use +60 °C<br />

- in a short cir cuit (max. 5 s) +150 °C<br />

Low est rec om mended<br />

han dling tem pera ture: +5 °C<br />

Mini mum rec om mended<br />

bend ing ra dius:<br />

- in nor mal us age 6xD<br />

CON STRUC TION<br />

Con duc tor An nealed cop per wires, str<strong>and</strong>ed<br />

flexi ble<br />

Light, flat, fle xib le, plas tic- in su la ted cord<br />

MSO H03VVH2-F<br />

2-wires<br />

RATED VOLT AGE<br />

U o /U = 300/300 V<br />

STAN DARD<br />

SFS 5525 = CENE LEC HD 21<br />

H03VVH2-F<br />

CORE IDEN TI FI CA TION<br />

N-system<br />

Self- extinguishing IEC 332-1<br />

Insulation PVC, core identification by colours<br />

Sheath PVC cov er ing two in su lated <strong>and</strong> par al lel<br />

con duc tors, flat<br />

WITHOUT PROTECTIVE CONDUCTOR<br />

Number <strong>and</strong> cross-section of<br />

conductors <strong>and</strong> sheath colour nxmm² 2 x 0,75 N VA 2 x 0,75 N HA 2 x 0,75 N RU 2 x 0,75 N MU<br />

EAN code (SSTL code) 64 100+ 04 181 20-1 04 181 21-8 04 181 22-5 04 181 23-2<br />

Nominal overall diameter mm 3,3x5,4 3,3x5,4 3,3x5,4 3,3x5,4<br />

Total weight kg/km 31 31 31 31<br />

Direct current resistance of<br />

conductor at +20 °C max. Ω/km 26,0 26,0 26,0 26,0<br />

St<strong>and</strong>ard delivery length<br />

spool m 200 200 200 200


N<br />

AP PLI CA TION<br />

Cord <strong>for</strong> light duty use <strong>for</strong> port able ap pli ences in<br />

do mes tic prem ises, kitch ens <strong>and</strong> of fices.<br />

- Not <strong>for</strong> kitchen or heat ing ap pli ances<br />

- Not <strong>for</strong> out door use, in dus trial use, ag ri cul tural use or<br />

<strong>for</strong> non do mes tic port able tools<br />

The weight of the light ing fix ture hang ing from the ca ble<br />

must not ex ceed 2 kg.<br />

Maxi mum per mis si bletem pera ture of con duc tor:<br />

- in con tinu ous use +60 °C<br />

- in a short cir cuit (max. 5 s) +150 °C<br />

Low est rec om mended<br />

han dling tem pera ture: +5 °C<br />

Mini mum rec om mended<br />

bend ing ra dius:<br />

- in nor mal us age 6xD<br />

CON STRUC TION<br />

Con duc tor An nealed cop per wires, str<strong>and</strong>ed<br />

flexi ble<br />

Light, round, fle xib le, plas tic- in su la ted cord<br />

MSOY H03VV-F<br />

2-wires<br />

RATED VOLT AGE<br />

U o /U = 300/300 V<br />

STAN DARD<br />

SFS 5525 = CENE LEC HD 21<br />

H03VV-F<br />

CORE IDEN TI FI CA TION<br />

N-system<br />

Self- extinguishing IEC 332-1<br />

Insulation PVC, core identification by colours<br />

Sheath PVC cov er ing two in su lated str<strong>and</strong>ed<br />

con duc tors, round<br />

WITHOUT PROTECTIVE CONDUCTOR<br />

Number <strong>and</strong> cross-section of<br />

conductors <strong>and</strong> sheath colour nxmm² 2 x 0,75 N VA 2 x 0,75 N MU<br />

EAN code (SSTL code) 64 100+ 04 181 70-6 04 181 73-7<br />

Nominal overall diameter mm 5,4 5,4<br />

Total weight kg/km 41 41<br />

Direct current resistance of<br />

conductor at +20 °C max. Ω/km 26,0 26,0<br />

St<strong>and</strong>ard delivery length<br />

spool m 100 100<br />

FLEXI BLE CORDS<br />

39


FLEXI BLE CORDS<br />

40<br />

N<br />

AP PLI CA TION<br />

Cord <strong>for</strong> or di nary duty use <strong>for</strong> port able ap pli ences in<br />

do mes tic prem ises, kitch ens <strong>and</strong> of fices.<br />

- For house hold ap pli ences in dry <strong>and</strong> damp prem ises.<br />

- Not <strong>for</strong> out door use, in dus trial use, ag ri cul tural use<br />

The weight of a light ing fix ture hang ing from the ca ble<br />

must not ex ceed 2 kg.<br />

Maxi mum per mis si bletem pera ture of con duc tor:<br />

- in con tinu ous use +60 °C<br />

- in a short cir cuit (max. 5 s) +150 °C<br />

Low est rec om mended<br />

han dling tem pera ture: +5 °C<br />

Mini mum rec om mended<br />

bend ing ra dius:<br />

- in nor mal us age 6xD<br />

Fle xib le, plas tic- in su la ted cord<br />

MSK H05VV-F<br />

2-wires<br />

RATED VOLT AGE<br />

U o /U = 300/500 V<br />

STAN DARD<br />

SFS 5525 = CENE LEC HD 21<br />

H05VV-F<br />

CORE IDEN TI FI CA TION<br />

N-system<br />

3-wires<br />

4-wires<br />

5-wires<br />

Self- extinguishing IEC 332-1<br />

S-ystem


CON STRUC TION<br />

Con duc tor An nealed cop per wires,<br />

str<strong>and</strong>ed flexi ble<br />

Fle xib le, plas tic- in su la ted cord<br />

MSK H05VV-F<br />

In su la tion PVC, core iden ti fi ca tion by col ours<br />

Sheath PVC, round<br />

WITH PROTECTIVE CONDUCTOR<br />

Number <strong>and</strong> cross-section of<br />

conductors <strong>and</strong> sheath colour nxmm² 3 x 0,75 S VA 3 x 1,0 S VA 3 x 1,5 S VA 4 x 0,75 S VA 4 x 1,5 S VA<br />

EAN code (SSTL code) 64 100+ 04 197 20-2 04 197 21-9 04 197 22-6 04 197 30-1 04 197 32-5<br />

Nominal overall diameter mm 6,6 7,0 8,3 7,2 9,3<br />

Total weight kg/km 61 72 100 75 130<br />

Direct current resistance of<br />

conductor at +20 °C max. Ω/km 26,0 19,5 13,3 26,0 13,3<br />

St<strong>and</strong>ard delivery length<br />

coil m 100 100 100 100 100<br />

WITH PROTECTIVE CONDUCTOR<br />

Number <strong>and</strong> cross-section of<br />

conductors <strong>and</strong> sheath colour nxmm² 5 x 1,0 S VA 5 x 1,5 S VA 5 x 2,5 S VA 3 x 1,5 S HA<br />

EAN code (SSTL code) 64 100+ 04 197 41-7 04 197 42-4 04 197 43-1 04 198 22-3<br />

Nominal overall diameter mm 8,6 10,3 12,2 8,3<br />

Total weight kg/km 110 165 250 102<br />

Direct current resistance of<br />

conductor at +20 °C max. Ω/km 19,5 13,3 7,98 13,3<br />

St<strong>and</strong>ard delivery length<br />

coil m 100 100 50 100<br />

WITHOUT PROTECTIVE CONDUCTOR<br />

Number <strong>and</strong> cross-section of<br />

conductors <strong>and</strong> sheath colour nxmm² 2 x 0,75 N VA 2 x 1,0 N VA 2 x 1,5 N VA<br />

EAN code (SSTL code) 64 100+ 04 194 10-2 04 194 11-9 04 194 12-6<br />

Nominal overall diameter mm 6,2 6,6 7,6<br />

Total weight kg/km 51 60 80<br />

Direct current resistance of<br />

conductor at +20 °C max. Ω/km 26,0 19,5 13,3<br />

St<strong>and</strong>ard delivery length<br />

coil m 100 100 100<br />

FLEXI BLE CORDS<br />

41


42<br />

DATA TRANS MIS SION CA BLES<br />

All auto ma tion ca bles, such as in stru men ta tion, sig nal <strong>and</strong><br />

data net work ca bles, are data trans mis sion ca bles.<br />

They are cop per ca bles with a maxi mum op er at ing<br />

volt age of 75 V or op ti cal fi bre ca bles.<br />

They trans mit in <strong>for</strong> ma tion in an elec tric or op ti cal <strong>for</strong>m.<br />

The trans mit ted in <strong>for</strong> ma tion may con sist of speech, sound,<br />

mov ing or still pic tures, text, data, meas ur ing or con trol<br />

data or it may be the sig nal of a fire de tec tor or<br />

a bur glar alarm.<br />

The trans mit ted sig nal may be ana log or digi tal.<br />

The ca pac ity of an ana log trans mis sion is meas ured by<br />

a b<strong>and</strong> width which is the fre quency range re quired to<br />

trans mit a cer tain sig nal. In digi tal trans mis sion a cer tain<br />

number of sig nals are trans mit ted in a time unit <strong>and</strong> this is<br />

called trans mis sion speed. A cer tain trans mis sion speed<br />

cor re sponds to a cer tain b<strong>and</strong> width. That is why the term<br />

b<strong>and</strong> width can also be used in digi tal trans mis sion.<br />

The b<strong>and</strong> width re quired by a digi tal sig nal is al ways<br />

wider than that of a cor re spond ing ana log sig nal.<br />

Ca ble de sign<br />

Data trans mis sion ca bles are di vided into three groups:<br />

sym met ri cal ca bles, co ax ial ca bles <strong>and</strong> op ti cal fi bre<br />

ca bles.<br />

a)<br />

b)<br />

c)<br />

conductor<br />

insulation<br />

inner conductor<br />

insulation<br />

outer conductor<br />

core<br />

shell<br />

(a) The ba sic struc ture of a sym met ri cal pair, (b) a co ax ial<br />

pair <strong>and</strong> (c) an op ti cal fi bre.<br />

A sym met ri cal ca ble con sist of one or sev eral sym met ri cal<br />

pairs. A pair con sists of two or four iden ti cal in su lated<br />

con duc tors which are mutually twisted into a pair.<br />

The con duc tors of a pair are alike in their elec tric<br />

dis po si tion. Sym met ri cal ca bles are either screened or<br />

un screened.<br />

A co ax ial pair is the ba sic ele ment of the co ax ial ca ble.<br />

It con sists of two con duc tors, an in ner con duc tor <strong>and</strong><br />

an outer con duc tor. These are dif fer ent in their struc ture<br />

<strong>and</strong> elec tric dis po si tion. The cy lin dri cal outer con duc tor<br />

is con cen tri cally around the in ner con duc tor.<br />

In an op ti cal fi bre ca ble, the sig nal pro ceeds in the <strong>for</strong>m of<br />

light along the op ti cal fi bre. The fi bre, con sist ing of a core<br />

<strong>and</strong> a shell, is made from quartz glass or plas tic.<br />

The re frac tive in dex of the core is higher than that of<br />

the shell, <strong>and</strong> this causes a re flec tion when the light hits<br />

the shell.<br />

GE NE RAL<br />

De pend ing on the dif fer ent in stal la tion con di tions,<br />

the ca bles are also di vided into in door ca bles <strong>and</strong> out door<br />

ca bles. Sel fex tin guish ing <strong>and</strong> bend abil ity are typi cal<br />

prop er ties of in door ca bles. They are also lighter in<br />

con struc tion <strong>and</strong> smaller in size than the cor re sponding<br />

out door ca bles. The serv ice tem pera ture range of out door<br />

ca bles is wide. They are re sis tant to e.g. hu mid ity, sun light<br />

<strong>and</strong> han dling in out door con di tions. De pend ing on<br />

the in stal lat ion site, out door ca bles can also be di vided<br />

into duct, bur ied, sub ma rine <strong>and</strong> aer ial ca bles.<br />

ELEC TRI CAL PROP ER TIES<br />

The trans mis sion ca pac ity of the ca ble is es sen tially<br />

ef fected by re sis tance, ca paci tance, im ped ance,<br />

at tenua tion <strong>and</strong> cros stalk.<br />

Re sis tance<br />

Re sis tance is caused by the con duc tor to<br />

the elec tric cur rent <strong>and</strong> it is de pend ent on the cross<br />

sec tion <strong>and</strong> the ma te rial of the con duc tor,<br />

the tem pera ture, the sig nal fre quency <strong>and</strong> the metals<br />

close to the con duc tor.<br />

For twisted- pair ca bles it is given as loop re sis tance which<br />

in cludes the ef fect of both the sup ply con duc tor <strong>and</strong><br />

the re turn con duc tor. The re sis tance is given per unit of<br />

the length, i.e Ω /km.<br />

Ca paci tance<br />

Ca paci tance is in er tia to volt age changes be tween<br />

the con duc tors of a pair. It is de pend ent on the di ame ter of<br />

the con duc tors, the dis tance be tween them,<br />

the in su la tion, the ma te rial around the in su la tion <strong>and</strong><br />

the elec tric po ten tial of the in su la tion.<br />

The ca paci tance in creases if the dis tance be tween<br />

the con duc tors is re duced or if the di ame ter of<br />

the con duc tors in creases. It is di rectly pro por tional to<br />

the di elec tric con stant which is spe cific to every in su la tion<br />

ma te rial. The ca paci tance is given per unit of the length,<br />

i.e. nF/km.<br />

Im ped ance<br />

Im ped ance gives the ra tio of the volt age be tween<br />

the con duc tors to the cur rent car ried therein. It is also<br />

known as surge im ped ance or char ac ter is tic im ped ance.<br />

With trans mis sion ca bles all these terms have the same<br />

mean ing. The unit of im ped ance is ohm (Ω).<br />

The im ped ance of ho mo ge ne ous pair is con stant across<br />

the whole length of the pair. The volt age <strong>and</strong> the cur rent<br />

are at tenu ated but their ra tio is con stant, i.e. equal to<br />

the im ped ance. The im ped ance is there <strong>for</strong>e one of<br />

the char ac ter is tics of a pair. At low fre quen cies,<br />

the im ped ance is sig nifi cant only with long ca bles.<br />

For ex am ple at a fre quency be low 29 kHz it be gins to have<br />

sig nifi cance if the ca ble is longer than 1,000 m.<br />

At a fre quency of 1,000 kHz or higher, the im ped ance is<br />

very im por tant <strong>for</strong> match ing. This means that<br />

the im ped ance of the unit or com po nent con nected to<br />

the pair must be equiva lent to that of the pair.


At tenua tion<br />

When the sig nal pro ceeds in the pair, it loses some of its<br />

ef fect, while both the volt age <strong>and</strong> the cur rent de crease<br />

as a func tion of the dis tance. The at tenua tion is given in<br />

deci bels per unit of length, e.g. dB/100 m, <strong>and</strong> it is<br />

af fected by the di ame ter of the in su la tion, the con duc tance<br />

of the con duc tor <strong>and</strong> the in su la tion prop er ties. The<br />

at tenua tion in creases with a higher fre quency <strong>and</strong> at a<br />

ris ing tem pera ture. With an in crease of one de gree in the<br />

tem pera ture, the in cre ment in the at tenua tion is 2 ‰.<br />

Cros stalk<br />

Cros stalk ap pears when sig nals are cou pled from one pair<br />

to an other. In sym met ri cal ca bles the cros stalk arises<br />

above all be cause of in com plete sym me try.<br />

Also the im ped ance match ings <strong>and</strong> cou pling modes of<br />

the pairs play a role in cros stalk which is an un de sired<br />

phe nome non. For a suc cess ful sig nal trans mis sion, it is<br />

im por tant to keep cros stalk within cer tain lim its.<br />

In ap pli ca tions with great dif fer ences in the sig nal lev els of<br />

the pairs, the ca ble must be es pe cially re sis tant to<br />

cros stalk.<br />

SE LEC TION OF THE CA BLE TYPE<br />

Data trans mis sion ca bles are speci fied in great de tail <strong>for</strong><br />

a number of ap pli ca tions. The choice is to be made<br />

ac cord ing to a speci fi ca tion or a stan dard. But this is not<br />

al ways pos si ble, which is why the fol low ing facts are very<br />

use ful.<br />

It is im por tant to con sider the pur pose <strong>for</strong> the use of<br />

the ca ble <strong>and</strong> the serv ice en vi ron ment be <strong>for</strong>e the ca bling<br />

plan is made.<br />

A ca ble is sub jected to me chani cal loads dur ing<br />

the in stal la tion. It may also be ex posed to vi bra tion, shock<br />

<strong>and</strong> fric tion in its serv ice en vi ron ment. These can of ten be<br />

avoided by proper rout ing or by shield ing the ca ble with<br />

a tube. Str<strong>and</strong>ed con duc tors are rec om mended <strong>for</strong> use in<br />

dif fi cult in stal la tion con di tions, be cause they are eas ier to<br />

bend <strong>and</strong> fatigue- resistant <strong>and</strong> will not break as eas ily as<br />

JA MAK ®<br />

JA MAK ® ARM<br />

CONTENTS<br />

wire con duc tors. Most str<strong>and</strong>ed con duc tors are tinned<br />

to pre vent cor ro sion.<br />

Ca bles are sub jected to chemi cal loads es pe cially in<br />

in dus trial en vi ron ments where they may be ex posed to oil<br />

<strong>and</strong> chemi cal spills <strong>and</strong> cor ro sive gases like sul phur<br />

di ox ide.<br />

Also high tem pera tures, a high rela tive hu mid ity <strong>and</strong><br />

fire risks must be taken into ac count when the ca ble is<br />

se lected.<br />

The sheath ing ma te rial has also a great sig nifi cance when<br />

air prop er ties are con sidered. The most com monly used<br />

ma te ri als are poly eth yl ene (PE) <strong>and</strong> poly vinyl chlo ride<br />

(PVC). PVC is the most popu lar sheath ing ma te rial in<br />

in door in stal la tions be cause it meets the re quire ments of<br />

the IEC 332-1 burn ing test, in which the ca ble is clas si fied<br />

as self- extinguishing. A PVC- sheathed ca ble is not<br />

self- burning <strong>and</strong> will not spread the fire. But, al most all<br />

or ganic mat ter is de stroyed by fire, which is why also<br />

the emis sion of smoke <strong>and</strong> the com bus tion resi due of<br />

the ca ble need to be taken into ac count. Burn ing PVC<br />

re leases chlo rine <strong>and</strong> it <strong>for</strong>ms with wa ter va pour<br />

haz ard ous hy dro chlo ric acid. This is why halogen- free<br />

ca bles are getting more popular (see sym met ri cal<br />

halogen- free lnstru men ta tion ca bles).<br />

And fluoro plas tics are the best of all - both elec tri cally <strong>and</strong><br />

me chani cally.<br />

The maxi mum serv ice tem pera ture with or di nary PE <strong>and</strong><br />

PVC ca bles is + 70 de grees Cel sius.<br />

The ca bles which are to be bur ied di rectly are gen er ally<br />

ar moured.<br />

Screen ing<br />

The elec tro mag netic in ter fer ence in the ca bles are<br />

ca paci tive, in duc tive or caused by a ra dia tion field.<br />

A gal vanic cou pling may also cause in ter fer ence.<br />

43


44<br />

The ta ble be low shows the types of in ter fer ence <strong>and</strong><br />

re spec tive screen ing:<br />

In ter fer ence Cause Screen ing<br />

Ca paci tive<br />

In duc tive<br />

Ra dia tion<br />

Gal vanic<br />

Cros stalk<br />

Elec tric field<br />

e.g. high- voltage ca ble<br />

Mag netic field<br />

e.g. power ca ble<br />

Ra dia tion field<br />

e.g. Radiotransmitter,<br />

ra dar, re lay or tran sis tor<br />

E.g. in cor rectly earthed<br />

serv ice net work<br />

Elec tro mag netic<br />

cou pling be tween the<br />

dif fer ent pairs of<br />

the ca ble<br />

Pair twist ing,con duct ing<br />

metal shields<br />

Pair twist ing, ar mour ing,<br />

fer ro mag netic screen ing<br />

Pair twist ing, con duct ing<br />

metal shields, proper<br />

earth ing<br />

The cir cuits are in su lated<br />

from each other <strong>and</strong> the<br />

ground<br />

Suit able twist length<br />

pairshielding<br />

Of course price is also an im por tant fac tor in<br />

the se lec tion of a ca ble. When you com pare the costs of<br />

e.g. screened <strong>and</strong> un screened ca bles, the fol low ing<br />

de tails are im por tant to re mem ber:<br />

— ca ble in vest ments are small com pared with<br />

the equip ment in vest ments<br />

— fail ures, <strong>for</strong> ex am ple be cause of in ade quate<br />

screen ing, are usu ally de tected in the serv ice -<br />

not be <strong>for</strong>e<br />

— re place ment of a ca ble af ter wards is ex pen sive,<br />

time- consuming <strong>and</strong> dif fi cult<br />

Ease of in stal la tion<br />

The slid ing prop er ties of the ca ble are im por tant <strong>for</strong><br />

in stal la tion.<br />

The ca ble is eas ier to pull if the sheath is made of<br />

low fric tion LINYL- PVC. This is the sheath ing ma te rial<br />

used by NK Ca bles uses in our in door ca bles. The rat ings<br />

should be ob served in the in stal la tion of each ca ble type.<br />

Avail abil ity, qual ity <strong>and</strong> tech ni cal sup port are other<br />

ma jor con sid era tions in the se lec tion of a ca ble.<br />

The fol low ing sum ma rized ques tions cover most of<br />

the es sen tial de tails:<br />

CONTENTS<br />

1. What is the type of the ca ble? (Even if the type is<br />

not known, get in touch <strong>and</strong> check if there is<br />

a simi lar type.)<br />

2. What kind of con nec tion or cou pling is used in<br />

the sys tem?<br />

3. What is the trans mis sion fre quency or the data<br />

trans mis sion speed?<br />

4. How many con duc tors or fi bres are needed in<br />

the ca ble?<br />

5. What is the im ped ance of the equip ment?<br />

6. What in ter fer ence is there in the en vi ron ment?<br />

(See the sec tion on screen ing.)<br />

7. What is the serv ice en vi ron ment <strong>for</strong> the ca bles <strong>and</strong><br />

what are they used <strong>for</strong>? Are they in door or out door<br />

ca bles? Is the in stal la tion fixed, semi fixed or mo bile?<br />

8. Is the ca ble sub jected to me chani cal or chemi cal<br />

loads?<br />

9. Con <strong>for</strong>mity to stan dards?<br />

IN DUS TRIAL NET WORKS<br />

In dus trial auto ma tion has developed rap idly in the past few<br />

years <strong>and</strong> will de velop at an ac cel er ated speed in<br />

the fu ture. Ca ble de sign fol low the lat est trends very<br />

closely. The ex ist ing ca ble de signs can be used in digi tal<br />

field buses, but also new designs are to come. Lo cal area<br />

net works have be come a part of in dus trial net works.<br />

At the mo ment they are used to han dle the trans mis sion<br />

at the high est level of in dus trial net works, i.e. Between<br />

the plant com puter <strong>and</strong> the pro cess com puter.<br />

More de tails must be taken into consideration in<br />

the de sign of in dus trial auto ma tion than in of fice.<br />

The buses of in dus trial auto ma tion sys tems are in tended<br />

<strong>for</strong> con tinu ing serv ice. It is im por tant that the mes sages<br />

are ab so lutely fault less <strong>and</strong> the re sponse times ac cu rate.<br />

Pro tec tion against in ter fer ences must be firm. This is seen<br />

e.g.in the ca ble con struc tions <strong>and</strong> their routings.<br />

Ca bles have a long serv ice life <strong>and</strong> are there <strong>for</strong>e<br />

an im por tant part of the in dus trial plant. Well- designed<br />

ca bling works <strong>for</strong> sev eral ma chine gen era tion. That is why<br />

spe cial at ten tion should be paid to the de sign <strong>and</strong><br />

im ple men ta tion of the ca bling.<br />

SYM MET RI CAL HALOGEN- FREE<br />

IN STRU MEN TA TION CA BLES<br />

Halogen free, HF-ca bles, pro vide bet ter fire safety than<br />

tra di tional PVC- sheathed ca bles. They are selfex<br />

tin guish ing like PVC- sheathed ca bles <strong>and</strong> do not spread<br />

the fire. In a fire they emit much less visi bil ity-re duc ing<br />

smoke than PVC- sheathed ca bles giv ing peo ple more time<br />

to es cape from the haz ard ous area <strong>and</strong> also more time <strong>for</strong><br />

fire fight ing. The smoke is also less ir ri tat ing <strong>and</strong> toxic. It<br />

doesn’t con tain harmfull hydrochloric acid or other<br />

cor ro sive gases <strong>for</strong> equipment of the structures. This<br />

pre vents smoke dam ages which are of ten larger than<br />

those caused by the fire.<br />

The self- extinguishing prop erty of the halogen free<br />

sheath ing ma te rial is based on eth yl ene co poly mers <strong>and</strong><br />

it’s sub stance which de com poses respond to heat with<br />

cool ing the ca ble <strong>and</strong> re leas ing wa ter va pour. The re sult<br />

of a pro tect ing layer of ash is <strong>for</strong>med on the ca ble <strong>and</strong><br />

around the ca ble an ex tin guish ing shield ing<br />

at mos phere of wa ter va pour. A dis ad van tage of<br />

the halogen- free ma te rial is that the sheath is less re sis tant<br />

to me chani cal loads <strong>and</strong> stiffer than a PVC sheath.<br />

Halogenfree ca bles are also sup plied by NK Ca bles.<br />

Fir e per<strong>for</strong>mance prop er ties of ca bles<br />

Prop erty Stan dard<br />

Flame re tar dant<br />

Fire re tar dant<br />

Fire re sis tant<br />

IEC 332-1<br />

IEC 332-3<br />

IEC 331<br />

Low smoke IEC 1034-1 ja IEC 1034-2<br />

Halo gen free,<br />

zero halo gen<br />

IEC 754-1 ja IEC 754-2<br />

(hal.quan tity


OP TI CAL FI BRE CA BLES IN IN DUS TRY<br />

Op ti cal fi bre ca bles are in creas ingly used in in dus try.<br />

This is di rectly pro por tional to the ex p<strong>and</strong> ing data<br />

trans mis sion. Op ti cal fi bre cables are used gen er ally at<br />

the high est level of in dus trial net works. There is also more<br />

<strong>and</strong> more needed <strong>for</strong> data trans mis sion at the lower lev els<br />

of the net work hi er ar chy. The mi cro com put ers used <strong>for</strong><br />

pro duc tion con trol are of ten next to the pro duc tion<br />

equip ment.<br />

The closer to the ma chines <strong>and</strong> equip ment the data<br />

trans mis sion lines run, the greater the elec tro mag netic<br />

in ter fer ence. Power trans fers, elec tric mo tor fields,<br />

thy ris tor con trols <strong>and</strong> elec tric weld ing are some of<br />

the ma jor sources of in ter fer ence. Also earth po ten tial<br />

dif fer ences <strong>and</strong> light ning may cause dis tur bances.<br />

The op ti cal fi bre ca ble is an ideal so lu tion <strong>for</strong><br />

an en vi ron ment ex posed to in ter fer ence. Since it is to tally<br />

in sen si tive to elec tro mag netic in ter fer ence, <strong>for</strong> ex am ple<br />

the ca ble rout ing can be made in the easi est pos si ble way.<br />

Even po ten tial dif fer ences are not a prob lem be cause<br />

fi bres are glass. A small at tenua tion will not cause<br />

prob lems at long trans mis sion dis tances. The large<br />

trans mis sion ca pac ity of the op ti cal fi bre ca ble can also be<br />

util ized in the fu ture, be cause the same ca ble sys tem will<br />

be suf fi cient <strong>for</strong> fu ture gen era tions of com put ers.<br />

Op ti cal fi bre ca ble does not cause spark ing <strong>and</strong> its small<br />

size is ad van ta geous <strong>for</strong> ex am ple in rout ing so lu tions.<br />

CONTENTS<br />

Price of fibre optics is high but in the in ter fer ence<br />

conditions to day fi bre op tics are also an eco nomi cally<br />

sen si ble so lu tion. Be sides it is of ten the only way of<br />

mak ing the con nec tion.<br />

Knowl edge of fi bre op tics is not nec es sary <strong>for</strong><br />

the con struc tion of an op ti cal fi bre con nec tion be cause<br />

there are ready- made so lu tions. The op ti cal fi bre<br />

con nec tion may be be tween two elec tric in ter faces or<br />

be tween two op ti cal fi bre con nec tors. The cli ent must only<br />

spec ify the length of the ca ble, the number of fi bres <strong>and</strong><br />

the con nec tor suited <strong>for</strong> the equip ment or the elec tric<br />

con nec tion. Es pe cially <strong>for</strong> short dis tances, it is sen si ble to<br />

in stall ready- made har nes sies in which the con nec tors are<br />

pro tected against me chani cal loads dur ing the in stal la tion.<br />

At long dis tances <strong>and</strong> with a large number of fi bres,<br />

the op ti cal fi bre ca ble should be ter mi nated at<br />

the in stal la tion site. This is a pro cess that re quires spe cial<br />

equip ment <strong>and</strong> knowl edge, <strong>and</strong> it may be pur chased as<br />

a serv ice from e.g. NK Ca bles, to gether with the ca ble <strong>and</strong><br />

the ter mi nal equip ment.<br />

More in <strong>for</strong> ma tion about op ti cal fi bre trans <strong>for</strong>m ers <strong>and</strong><br />

ca bles, ter mi na tion boxes <strong>and</strong> cross- connection sys tems<br />

<strong>for</strong> fi bre op tics are found in the prod uct cata logues<br />

“Op ti cal Tele com mu ni ca tions <strong>and</strong> Lo cal Area Ca bles” <strong>and</strong><br />

“Ac ces so ries <strong>and</strong> Sup plies <strong>for</strong> Op ti cal Fi bre Ca bles”.<br />

45


IN STRU MEN TA TION CA BLES<br />

46<br />

AP PLI CA TIONS<br />

— Fixed in door — Proc ess con trol<br />

in stal la tions — Audio sys tems<br />

— Auto ma tion — Suit able <strong>for</strong> Maxi<br />

— In stru men ta tion Ter mipoint con nec tions<br />

Suit able spe cially <strong>for</strong> digi tal <strong>and</strong> low level analog sig nal<br />

trans mis sion. The con struc tion gives an ex cel lent<br />

pro tec tion against elec tro mag netic in ter fer en cies.<br />

Maxi mum ambient tem pera ture:<br />

- in operation +70 °C<br />

CON STRUC TION<br />

Con duc tor Str<strong>and</strong>ed tinned cop per<br />

In su la tion PE<br />

Unit Twisted <strong>and</strong> in di vidu ally with<br />

plas tic-alu min ium tape shielded pair,<br />

earth con duc tor <strong>and</strong> a number tape<br />

CA BLE SIZES<br />

Instru men ta ti on cab le<br />

JA MAK ®<br />

IDEN TI FI CA TION<br />

Units marked with numbers,<br />

a- conductors are blue <strong>and</strong> b- conductors are red.<br />

The cable ful fils the fire con di tion re quire ments of<br />

IEC 332-1 (Flame re tar dant).<br />

Shield Plas tic-alu min ium tape with earth<br />

con duc tor<br />

Sheath Grey LINYL- PVC<br />

Num ber <strong>and</strong> size of<br />

the con duc tors mm 2 2 x( 2+1) x 0,5 4 x (2+1) x 0,5 8 x (2+1) x 0,5 12 x (2+1) x 0,5 24 x (2+1) x 0,5 48 x (2+1) x 0,5<br />

EAN code (SSTL code) 64 100+ 02 642 52-0 02 642 54-4 02 642 58-2 02 642 62-9 02 642 64-3 02 642 68-1<br />

Nomi nal di ame ter mm 8,0 9,5 13,0 15,0 21,0 29,0<br />

Mass kg/km 70 110 200 280 530 1000<br />

De liv ery length m 1000/200 1000/200 1000 1000 1000 500<br />

ELEC TRI CAL PROP ER TIES, 20 °C<br />

Maxi mum loop re sis tance Ω/km 81<br />

Nomi nal mu tual ca paci tance<br />

(800 Hz) nF/km 85<br />

Im ped ance, 10 MHz Ω 70 ± 10 %<br />

Mini mum in su la tion re sis tance GΩ x km 2<br />

Ve loc ity fac tor 0,66<br />

Maxi mum volt age V 75<br />

Nomi nal at tenua tion dB/100 m<br />

fre quency 9,6 kHz<br />

fre quency 19,2 kHz<br />

fre quency 64 kHz<br />

fre quency 100 kHz<br />

fre quency 200 kHz<br />

fre quency 1,0 MHz<br />

Low est rec om mended installation<br />

tem pera ture: –5 °C<br />

Mini mum rec om mended bend ing ra dius:<br />

- dur ing in stal la tion 15xD<br />

- during operation 10xD<br />

JA MAK is also available as halo gen free (JAMAK- HF) <strong>and</strong> more effectively shielded (JAMAK-C) ver sion.<br />

0,3<br />

0,5<br />

0,7<br />

0,9<br />

1,6<br />

4,5


AP PLI CA TIONS<br />

— Fixed out door — Proc ess con trol<br />

in stal la tions — Audio sys tems<br />

— Auto ma tion — Suit able <strong>for</strong> Maxi<br />

— In stru men ta tion Ter mipoint con nec tions<br />

Suit able spe cially <strong>for</strong> digi tal <strong>and</strong> low level analog sig nal<br />

trans mis sion. The con struc tion gives an ex cel lent<br />

pro tec tion against elec tro mag netic in ter ference.<br />

Maxi mum ambient tem pera ture:<br />

- in operation +70 °C<br />

CONSTRUC TION<br />

Con duc tor Str<strong>and</strong>ed tinned cop per<br />

In su la tion PE<br />

Unit Twisted <strong>and</strong> in di vidu ally with<br />

plas tic-alu min ium tape shielded pair,<br />

earth con duc tor <strong>and</strong> a number tape<br />

CA BLE SIZES<br />

Num ber <strong>and</strong> size of<br />

the con duc tors mm 2 4 x (2+1) x 0,5<br />

Instru men ta ti on cab le<br />

JA MAK ® ARM<br />

IN STRU MEN TA TION CA BLES<br />

Low est rec om mended installation<br />

tem pera ture: –5 °C<br />

Mini mum rec om mended bend ing ra dius:<br />

- dur ing in stal la tion 15xD<br />

- during operation 10xD<br />

Shield Plas tic/alu min ium tape with earth<br />

con duc tor<br />

Sheath Grey LINYL- PVC<br />

Ar mour ing Wrapped steel b<strong>and</strong><br />

Outersheath Black PVC<br />

8 x (2+1) x 0,5 12 x (2+1) x 0,5 24 x (2+1) x 0,5 48 x (2+1) x 0,5<br />

EAN code (SSTL code) 64 100+ 02 642 72-4 02 642 78-0 02 642 82-7 02 642 84-1 02 642 88-9<br />

Nomi nal di ame ter mm 9,5 13,0 15,0 21,0 29,0<br />

Nomi nal di ame ter mm 13,5 17,0 19,0 25,0 33,0<br />

Mass kg/km 240 350 470 820 1420<br />

De liv ery lenght m 1000 1000 1000 1000 500<br />

ELEC TRI CAL PROP ER TIES<br />

Maxi mum loop re sis tance Ω/km 81<br />

Nomi nal mu tual ca paci tance<br />

(800 Hz) nF/km 85<br />

Im ped ance, 10 MHz Ω 70 ± 10 %<br />

Mini mum in su la tion re sis tance GΩ x km 2<br />

Ve loc ity fac tor 0,66<br />

Maxi mum volt age V 75<br />

Nomi nal at tenua tion dB/100 m<br />

fre quency 9,6 kHz<br />

fre quency 19,2 kHz<br />

fre quency 64 kHz<br />

fre quency 100 kHz<br />

fre quency 200 kHz<br />

fre quency 1,0 MHz<br />

IDEN TI FI CA TION<br />

Units marked with number tape,<br />

a- conductors are blue <strong>and</strong> b- conductors are red.<br />

JA MAK ARM is also available as halo gen free (JAMAK ARM- HF) <strong>and</strong> more effectively shielded (JAMAK-C-ARM) ver sion.<br />

0,3<br />

0,5<br />

0,7<br />

0,9<br />

1,6<br />

4,5<br />

47


IN STRU MEN TA TION CA BLES<br />

48<br />

USE<br />

The EMC-directive came into <strong>for</strong>ce 1.1.1996. EMC means<br />

Elec tro mag netic Com pat ibil ity. This EMC- directive is<br />

applied to equipment <strong>and</strong> sys tems, but not <strong>for</strong><br />

com po nents <strong>and</strong> equip ment, so ca bles alone are out side<br />

this directive. How ever ca bles are a part of a sys tem <strong>and</strong> it<br />

is clear that cables with bet ter EMC- properties are<br />

required.<br />

NK Ca bles has developed a more effectively shielded<br />

version of in stru men ta tion ca ble JA MAK called JAMAK-C<br />

which has bet ter EMC- properties.<br />

In stal la tions which de m<strong>and</strong> bet ter EMC- properties, where<br />

in stru ments <strong>and</strong> sys tems, are ex pected to work de spite of<br />

elec tro mag netic dis tur bances <strong>and</strong> wi thout dis turb ing other<br />

in stru ments <strong>and</strong> sys tems elec tro mag neti cally.<br />

CON STRUC TION<br />

Dou ble alu mini um foil pro tec tion: two plas tic-alu min ium<br />

tapes <strong>and</strong> ground wire be tween tapes with thicker<br />

alu min ium tape having the met al coating on the out side<br />

(plas tic-alu min ium tape) it is pos si ble to make a contact<br />

with the shield in lead- throughs <strong>and</strong> con nec tors in<br />

a an gle of 360°.<br />

Instal la ti ons which de m<strong>and</strong> bet ter EMC- pro per ties<br />

JA MAK ® -C<br />

ELEC TRI CAL PROP ER TIES<br />

Screening effectiveness of ca bles can be de scribed with<br />

trans fer impedance, unit is mΩ/m. The smaller<br />

the trans fer impedance, the bet ter are the EMC/shield ing<br />

prop er ties of the ca bles.<br />

In the ta ble be low are compared or di nary JA MAK <strong>and</strong><br />

JAMAK-C, trans fer impedances.<br />

Fre quency<br />

MHz<br />

50<br />

100<br />

IN STAL LA TION<br />

Trans fer impedance, nominal<br />

mΩ/m<br />

JA MAK JAMAK-C<br />

2,0<br />

3,0<br />

0,4<br />

0,3<br />

When the sheath is taken away, the outer plas ticalu<br />

min ium tape can also be taken away. Then comes the<br />

in ner plas tic-alu min ium tape the metalcoating on the<br />

outside. Af ter this it is pos si ble to make a contact with the<br />

shield <strong>and</strong> connector ac cord ing to connector<br />

manu fac torer’s ad vice in a angle of 360°.<br />

In ner<br />

alu min ium tape<br />

Outer<br />

alu min ium tape Ground wire<br />

The right to al tera tions re served.


Maxi mum ambient tem pera ture:<br />

- in operation +70 °C<br />

Low est rec om mended installation<br />

tem pera ture: –5 °C<br />

Mini mum rec om mended bend ing ra dius:<br />

- dur ing in stal la tion 15xD<br />

- during operation 10xD<br />

CONSTRUC TION<br />

Con duc tor Str<strong>and</strong>ed tinned cop per<br />

In su la tion PE<br />

Unit Twisted <strong>and</strong> in di vidu ally with<br />

plas tic-alu min ium tape shielded pair,<br />

earth con duc tor <strong>and</strong> a number tape<br />

CA BLE SIZES<br />

Instru men ta ti on cab le<br />

JA MAK ® -C<br />

IN STRU MEN TA TION CA BLES<br />

Num ber <strong>and</strong> size of<br />

the con duc tors mm 2 2 x (2+1) x 0,5 4 x (2+1) x 0,5 8 x (2+1) x 0,5 12 x (2+1) x 0,5 24 x (2+1) x 0,5 48 x (2+1) x 0,5<br />

EAN code (SSTL code) 64 100+ 02 642 22-3 02 642 24-7 02 642 26-1 02 642 28-5 02 642 30-8 02 642 32-2<br />

Nomi nal di ame ter mm 8,5 10,0 13,5 15,5 21,5 29,5<br />

Mass kg/km 75 115 210 290 540 1030<br />

De liv ery lenght m 1000 1000 1000 1000 1000 500<br />

ELEC TRI CAL PROP ER TIES<br />

Maxi mum loop re sis tance Ω/km 81<br />

Nomi nal mu tual ca paci tance<br />

(800 Hz) nF/km 85<br />

Im ped ance, 10 MHz Ω 70 ± 10<br />

Mini mum in su la tion re sis tance GΩ x km 2<br />

Ve loc ity fac tor 0,66<br />

Maxi mum volt age V 75<br />

Nomi nal at tenua tion dB/100 m<br />

fre quency 9,6 kHz<br />

fre quency 19,2 kHz<br />

fre quency 64 kHz<br />

fre quency 100 kHz<br />

fre quency 200 kHz<br />

fre quency 1,0 MHz<br />

IDEN TI FI CA TION<br />

Unit marked with number tape,<br />

a- conductors are blue <strong>and</strong> b- conductors are red.<br />

The cable ful fils the fire con di tion re quire ments of<br />

IEC 332-1 (Flame re tar dant)<br />

Com mon Two plas tic-alu min ium tapes <strong>and</strong><br />

a ground<br />

Shield wire be tween tapes<br />

Sheath Grey LINYL- PVC<br />

JAMAK-C is also available as halo gen free (JAMAK- C- HF) ver sion. The right to al tera tions re served.<br />

0,3<br />

0,5<br />

0,7<br />

0,9<br />

1,6<br />

4,5<br />

49


IN STRU MEN TA TION CA BLES<br />

50<br />

AP PLI CA TIONS<br />

— Fixed in door — Proc ess con trol<br />

in stal la tions — Suit able <strong>for</strong> Maxi Ter mipoint<br />

— Auto ma tion con nec tions<br />

— In stru men ta tion<br />

Maxi mum ambient tem pera ture:<br />

- in operation +70 °C<br />

Low est rec om mended installation<br />

tem pera ture: –5 °C<br />

CON STRUC TION<br />

Con duc tor Str<strong>and</strong>ed tinned cop per<br />

In su la tion PVC<br />

Unit Twisted pair<br />

CA BLE SIZES<br />

Num ber <strong>and</strong> size of<br />

the con duc tors mm 2<br />

Instru men ta ti on cab le<br />

NO MAK ®<br />

IDEN TI FI CA TION<br />

Pairs marked with num bers,<br />

a- conductors are or ange <strong>and</strong> b- conductors are white.<br />

Over all shield Plas tic/alu min ium tape with earth<br />

con duc tor<br />

Shealth Grey LINYL- PVC<br />

2 x 2 x 0,5 4 x 2 x 0,5 8 x 2 x 0,5 12 x 2 x 0,5 24 x 2 x 0,5 48 x 2 x 0,5<br />

EAN code (SSTL code) 64 100+ 02 649 52-9 02 649 54-3 02 649 58-1 02 649 62-8 02 649 64-2 02 649 68-0<br />

Nomi nal di ame ter mm 7,5 8,5 11,0 14,0 19,0 25,0<br />

Mass kg/km 60 85 150 210 400 720<br />

De liv ery length m 1000/200 1000/200 1000 1000 1000 1000<br />

ELEC TRI CAL PROP ER TIES 20 °C<br />

Maxi mum loop re sis tance Ω/km 81<br />

Nomi nal mu tual ca paci tance<br />

(800 Hz) nF/km 90 85<br />

Im ped ance, 10 MHz Ω 100 ± 10 %<br />

Mini mum in su la tion re sis tance MΩ x km 100<br />

Ve loc ity fac tor 0.60<br />

Maxi mum volt age V 75<br />

Nomi nal at tenua tion dB/100 m<br />

fre quency 9,6 kHz<br />

fre quency 19,2 kHz<br />

fre quency 64 kHz<br />

fre quency 100 kHz<br />

fre quency 200 kHz<br />

fre quency 1,0 MHz<br />

Mini mum rec om mended bend ing ra dius:<br />

- dur ing in stal la tion 15xD<br />

- during operation 10xD<br />

The cable ful fils the fire con di tion re quire ments of<br />

IEC 332-1 (Flame re tar dant).<br />

NO MAK is also available as halo gen free (NOMAK- HF) ver sion. The right to al tera tions re served.<br />

0,3<br />

0,5<br />

0,7<br />

0,9<br />

1,5<br />

2,9


AP PLI CA TIONS<br />

— Fixed in door — Proc ess con trol<br />

in stal la tions — Suit able <strong>for</strong> Maxi Ter mipoint<br />

— Auto ma tion con nec tions<br />

— In stru men ta tions<br />

Maxi mum ambient tem pera ture:<br />

- in operation +70 °C<br />

Low est rec om mended installation<br />

tem pera ture: –5 °C<br />

CON STRUC TION<br />

Con duc tor Str<strong>and</strong>ed tinned cop per<br />

In su la tion PVC<br />

Unit Twisted pair<br />

CA BLE SIZES<br />

Instru men ta ti on cab le<br />

NO MAK-E ®<br />

IN STRU MEN TA TION CA BLES<br />

Mini mum rec om mended bend ing ra dius:<br />

- dur ing in stal la tion 15xD<br />

- during operation 10xD<br />

IDEN TI FI CA TION<br />

Pair a-wire b-wire Pair a-wire b-wire<br />

1 blue red 3 green brown<br />

2 grey yellow 4 white black<br />

Num ber <strong>and</strong> size of<br />

the con duc tors mm 2 2 x 2 x 0,5 4 x 2 x 0,5 8 x 2 x 0,5 12 x 2 x 0,5 24 x 2 x 0,5<br />

EAN code (SSTL code) 64 100+ 02 649 53-6 02 649 55-0 02 649 59-8 02 649 63-5 02 649 65-9<br />

Nomi nal di ame ter mm 7,5 8,5 11,0 14,0 19,0<br />

Mass kg/km 60 85 150 210 400<br />

De liv ery length m 1000 1000 1000 1000 1000<br />

ELEC TRI CAL PROP ER TIES 20 °C<br />

Maxi mum loop re sis tance Ω/km 81<br />

Nomi nal mu tual ca paci tance<br />

(800 Hz) nF/km 90 85<br />

Im ped ance, 10 MHz Ω 100 ± 10 %<br />

Mini mum in su la tion re sis tance MΩ x km 100<br />

Ve loc ity fac tor 0.60<br />

Maxi mum volt age V 75<br />

Nomi nal at tenua tion dB/100 m<br />

fre quency 9,6 kHz<br />

fre quency 19,2 kHz<br />

fre quency 64 kHz<br />

fre quency 100 kHz<br />

fre quency 200 kHz<br />

fre quency 1,0 MHz<br />

Every four -pair unit marked with a number tape.<br />

The cable ful fils the fire con di tion re quire ments of<br />

IEC 332-1 (Flame re tar dant).<br />

Overall Plas tic/alu min ium tape with<br />

earth con duc tor shield<br />

Shealth Grey LINYL- PVC<br />

NOMAK-E is also available as halo gen free (NOMAK- E- HF) ver sion. The right to al tera tions re served.<br />

0,3<br />

0,5<br />

0,7<br />

0,9<br />

1,5<br />

2,9<br />

51


IN STRU MEN TA TION CA BLES<br />

52<br />

AP PLI CA TIONS<br />

Automation/ Istru men ta ti on cab les<br />

FKAR-PG n x 2 x 0,5 mm 2<br />

— In door — Proc ess con trol<br />

in stal la tions — Auto ma tion<br />

— In stru men ta tion<br />

Maxi mum ambient tem pera ture:<br />

- in operation +70 °C<br />

Low est rec om mended installation<br />

tem pera ture: –30 °C<br />

- During installation -5 °C<br />

CON STRUC TION<br />

Con duc tor Str<strong>and</strong>ed tinned cop per 0,5 mm 2<br />

In su la tion Black PVC<br />

Unit Twisted pair<br />

CA BLE SIZES<br />

Mini mum rec om mended bend ing ra dius:<br />

- dur ing in stal la tion 15xD<br />

STANDARD<br />

SS 4240323<br />

SS 4241475 Class 3, (Flame re tar dant).<br />

IDEN TI FI CA TION<br />

Insulation colour: black<br />

Each conductor with white number marking<br />

Over all shield Plas tic/alu min ium foil with drain<br />

wire<br />

Shealth Grey PVC<br />

Type 1 x 2 x 0,5 2 x 2 x 0,5 4 x 2 x 0,5 8 x 2 x 0,5 16 x 2 x 0,5 24 x 2 x 0,5 48 x 2 x 0,5<br />

Nomi nal di ame ter mm 6,0 9,0 10,5 14,0 18,0 21,5 29,0<br />

Mass kg/km 56 88 125 210 370 520 980<br />

ELEC TRI CAL PROP ER TIES<br />

Maxi mum loop re sis tance Ω/km 81<br />

Mini mum in su la tion re sis tance MΩ x km 100<br />

Maxi mum volt age V 150/ 250<br />

Nomi nal at tenua tion dB/100 m<br />

fre quency 9,6 kHz<br />

fre quency 19,2 kHz<br />

0,4<br />

0,6


AP PLI CA TIONS<br />

— Fixed in door — In stru men ta tion<br />

in stal la tions — Auto ma tion<br />

Suit able <strong>for</strong> long dis tance trans mis sion.<br />

Maxi mum ambient tem pera ture:<br />

- in operation +70 °C<br />

Low est rec om mended installation<br />

tem pera ture: –5 °C<br />

Mini mum rec om mended bend ing ra dius:<br />

- dur ing in stal la tion 15xD<br />

- during operation 10xD<br />

CON STRUC TION<br />

Con duc tor Str<strong>and</strong>ed tinned cop per<br />

In su la tion PVC<br />

CA BLE SIZES<br />

Instru men ta ti on cab le<br />

KLAM 3 x 1,5 + 1,5<br />

IDEN TI FI CA TION<br />

Num ber <strong>and</strong> size of<br />

the con duc tors mm 2 3 x 1,5+1,5<br />

EAN code (SSTL code) 64 100+ 02 640 03-8<br />

Nomi nal di ame ter mm 8,5<br />

Mass kg/km 115<br />

De liv ery length m 1000<br />

ELEC TRI CAL PROP ER TIES 20 °C<br />

Maxi mum loop re sis tance Ω/km 24<br />

Mini mum in su la tion re sis tance MΩ x km 500<br />

Maxi mum volt age V 75<br />

IN STRU MEN TA TION CA BLES<br />

a- conductor is blue, b- conductor is red <strong>and</strong><br />

c- conductor is white.<br />

The cable ful fils the fire con di tion re quire ments of<br />

IEC 332-1 (Flame re tar dant).<br />

Unit Twisted con duc tors shielded with<br />

plas tic/alu min ium tape, earth con duc tor<br />

Sheath Grey LINYL- PVC<br />

KLAM is also available as halo gen free (KLAM- HF) ver sion. The right to al tera tions re served.<br />

53


IN STRU MEN TA TION CA BLES<br />

54<br />

APPLICATION<br />

These symmetrical data transmission cables are used in<br />

control <strong>and</strong> supervision centres <strong>for</strong> industrial units. They<br />

are suitable <strong>for</strong> fixed installation inside housing. <strong>Cables</strong><br />

with rein<strong>for</strong>ced or douple outer sheath can be installed<br />

also outdoors <strong>for</strong> direct burial.<br />

CONSTRUCTION<br />

Multi-wired conductor or plain copper adapted to<br />

Maxi-Termi-Point connection; conductor insulation<br />

consists of PVC or halogen free material. Cores ar twisted<br />

to pairs with short loops inside a unit featuring good<br />

nearend crosstalk attenuation. Overall shielding of either<br />

aluminium laminated plastic foil or copper braid prevents<br />

EMC interference.<br />

IDENTIFICATION<br />

Conductors<br />

Pair no.<br />

Every unit with number coding<br />

Sheath colours<br />

Grey, resp. Blue <strong>for</strong> intrinsic safe systems at inhouse<br />

application; black <strong>for</strong> outdoor installation<br />

Sheath printing<br />

Manufacturer, type coding including conductor dimension<br />

<strong>and</strong> number of pairs, metre marking<br />

Symmetrical data transmission cables<br />

RD-<br />

Color<br />

a-conductor a-conductor<br />

1 blue red<br />

2 grey yellow<br />

3 green brown<br />

4 white black<br />

Cable description<br />

RD Y (St) Y n x 2 x 0,5<br />

number of pairs x conductor cross<br />

section<br />

Y outer sheath PVC (+70 °C)<br />

Yv rein<strong>for</strong>ced outer sheath PVC<br />

<strong>for</strong> direct burial<br />

Yw outer sheath heat resistant<br />

PVC (+90 °C)<br />

Yu outer sheath flame retardent PVC<br />

(LOI s30), IEC 332-1<br />

YuFR outer sheath fire retardent PVC<br />

(LOI s30), IEC 332-3C<br />

H outer sheath halogen free,<br />

IEC 332-3C<br />

St static shielding (foil)<br />

C copper braid shielding<br />

Y conductor insulation PVC (+70 °C)<br />

Yw conductor insulation heat resistant<br />

PVC (+90 °C)<br />

H conductor insulation halogen free<br />

R “Rechnerkabel”<br />

(str<strong>and</strong>ing min. 20 loops/m)<br />

D DECONTIC<br />

(registered trade mark of ABB)<br />

Also available<br />

RD-Y(St)Y with PVC outer sheath<br />

RD-Y(St)Yu with special flame retardent PVC<br />

outer sheath<br />

RD-H(St)H with halogen free outer sheath<br />

RD-Yw(C)Yw with heat resistant PVC outer sheath<br />

<strong>and</strong> braided copper


AP PLI CA TIONS<br />

Fixed installation inside housing<br />

Maxi mum ambient tem pera ture:<br />

- in operating -40 °C ...+70 °C<br />

Low est rec om mended installation<br />

tem pera ture: –5 °C<br />

Fire behaviour:<br />

oxygen index LOI acc. To ASTM-D-2863 no limit<br />

smoke density acc. To ASTM-D-2843 90 %<br />

HCL emission acc. To IEC 754-1 >25 %<br />

fire propagation acc. To IEC 332-1<br />

CON STRUC TION<br />

Con duc tor plain copper wire,<br />

0,5 mm 2 /7x0,3 mm 2 Ø)<br />

In su la tion PVC, Ø 1,5 mm<br />

Str<strong>and</strong>ing 2 conductors per pair<br />

CA BLE SIZES<br />

Symmetrical data transmission cables<br />

RD-Y(St)Y<br />

IDEN TI FI CA TION<br />

Core str<strong>and</strong>ing (0+4)<br />

Shielding Al-laminated plastic foil +<br />

drain wire 0,5 mm 2<br />

Outer shealth PVC<br />

Pert. no C17582000 C17582100 C17582200 C17582300 C17582400 C17582500 C17582600 C17582700 C17582800<br />

Type 2x2x0,5 4x2x0,5 8x2x0,5 12x2x0,5 16x2x0,5 24x2x0,5 32x2x0,5 48x2x0,5 96x2x0,5<br />

Outer di ame ter mm 6,5 ± 0,5 9,0 ± 0,5 11,5 ± 0,5 13,0 ± 0,8 14,5 ± 0,8 17,5 ± 1,0 20,0 ± 1,0 24,0 ± 1,0 32,5 ± 1,5<br />

Mass kg/km 65 110 190 240 300 420 570 800 1500<br />

Cu-content 25 45 85 125 165 245 325 485 965<br />

Bending radius mm 50 70 90 100 110 135 150 180 250<br />

De liv ery length m 4000 2000 2000 2000 2000 2000 2000 1000 500<br />

ELEC TRI CAL PROP ER TIES 20 °C<br />

Maxi mum loop re sis tance Ω/km 73,6<br />

Nomi nal mu tual ca paci tance<br />

(800 Hz) nF/km<br />

4x2 nF/km<br />

Mini mum in su la tion re sis tance MΩ x km 100<br />

Nominal impedance<br />

(at 1 kHz) Ω<br />

(at 1 kHz) Ω<br />

Maxi mum volt age V 600<br />

Test voltage (at 50 Hz, 2 min)<br />

cond./conductor V<br />

cond./shield<br />

Nomi nal at tenua tion dB/100 m<br />

fre quency 1,0 kHz<br />

fre quency 10,0 kHz<br />

Pair no.<br />

100<br />

120<br />

370<br />

130<br />

2000<br />

2000<br />

1,2<br />

3,0<br />

IN STRU MEN TA TION CA BLES<br />

Color<br />

a-conductor a-conductor<br />

1 blue red<br />

2 grey yellow<br />

3 green brown<br />

Every unit with number coding<br />

The right to al tera tions re served.<br />

55


IN STRU MEN TA TION CA BLES<br />

56<br />

JA MAK ® & JA MAK ® ARM<br />

JOIN TING<br />

Pair shields <strong>and</strong> the com mon shield are spliced <strong>and</strong><br />

earthed by a cop per con duc tor. It is im por tant in the<br />

joint ing <strong>and</strong> ter mi nal con nec tions that the pair shields are<br />

in su lated one from<br />

the an other, ex cept <strong>for</strong> the com mon ground ing point.<br />

If the joint ing has to be EMC pro tected, the shields have to<br />

be jointed all around i.e. 360°.<br />

SPLIC ING<br />

1. The sheath is stripped. The in ner sheath is pulled<br />

open by the tear- off wire.<br />

2. The pair shield is opened <strong>and</strong> re moved<br />

1<br />

1<br />

1<br />

pull off<br />

1<br />

3. Splic ing of a pair<br />

pair sleeve<br />

2-12 pair<br />

25<br />

30<br />

50 40<br />

24 <strong>and</strong> 48 pairs<br />

2. cut<br />

1. cut<br />

earth conductor<br />

1<br />

2<br />

strip<br />

100<br />

1<br />

3<br />

1<br />

2<br />

1<br />

2<br />

1<br />

3 3<br />

2<br />

4 4<br />

3<br />

2<br />

4<br />

3<br />

4<br />

4<br />

1<br />

1<br />

1<br />

conductor sleeve<br />

joint gap<br />

1 1 1 1<br />

An in door ca ble is jointed with out steps 6 <strong>and</strong> 7.<br />

1<br />

1<br />

1 1<br />

The length of the splice de pends on the number of<br />

the pairs:<br />

Number of pairs 2 4 8 12 24 48<br />

Joint gap mm 280 280 280 280 400 400<br />

4. Splic ing of the earth con duc tor of the pair shield<br />

5. Com plete pair joint<br />

pair insulation<br />

Note! If the joint ing has to be EMC pro tected,<br />

the shields have to be jointed all around i.e. 360°.<br />

6. Splic ing of the in ner sheath<br />

7. Splic ing of the ar mour ing<br />

8. Com plete joint<br />

earth conductor splice<br />

1 1 1 1 1<br />

thermal protection earth conductor splice <strong>for</strong><br />

the common shield<br />

copper braid<br />

shrink-on tube<br />

soldering<br />

outer shrink-on tube inner shrink-on tube<br />

shrink-on tube<br />

The right to al tera tions re served.


DISTRIBUTED DATA SYS TEMS OF<br />

BUIL DING TECH NO LOGY<br />

LON (Lo cal Op er at ing Net work)<br />

- LON is field bus that en ables the distributed data<br />

sys tems in build ings<br />

- based on the Neuron- prosessor of Eche lon Co<br />

- cho sen by the Fin nish build ing as so cia tion as<br />

the ba sis of SaMBA- project<br />

- LON is a build ing auto ma tion sys tem which con trols<br />

lights, heat ing, air con di tion ing, elec tric ity, se cu rity<br />

sys tems of build ings with in tel li gent auto ma tion sys tems<br />

- LON- net/In tel li gent nodes. They use the same lan guage,<br />

which is Lon Talk. LON- bus is open <strong>and</strong> suit able <strong>for</strong><br />

prod ucts of dif fer ent manu fac turers<br />

- LON- net does not need cen tral ized con trol<br />

- Ap pli ca tions are build ings, in dus try <strong>and</strong> pro cess<br />

auto ma tion, ve hi cles <strong>and</strong> small sys tems<br />

- Lon Works networks is becoming the dominant st<strong>and</strong>art<br />

<strong>for</strong> home networking around the world.<br />

It is very im por tant to plan ca bling sys tems so that it is<br />

pos si ble to con nect in tel li gent switches <strong>and</strong> nodes eas ily<br />

<strong>and</strong> make so lu tions which work prop erly in the fu ture too.<br />

The LON ca bles of NK Ca bles ful fil re quire ments of<br />

Echelon specification, which describes ca bling sys tems<br />

<strong>and</strong> re quire ments.<br />

LON<br />

4-way breakout box<br />

The last outlet includes terminating resistor<br />

RJ 45-female connector<br />

LON-outlet<br />

Connection cable<br />

RJ 45 - RJ 45<br />

LON- Cabling<br />

LON -Ca bling can be realized with three dif fer ent con duc tor<br />

sizes (1,3 mm, 0,8 mm <strong>and</strong> 0,65 mm).<br />

LON- cables of NK Ca bles are:<br />

LO NAK ®<br />

2 x 1,3<br />

LO NAK ® ARM 2 x 1,3<br />

LO NAK ® 2 x 2 x 0,8<br />

LO NAK ®<br />

2 x 2 x 0,65<br />

LON Ca bling works also with Cat. 5 ca bles, but only with<br />

shorter con nec tions <strong>and</strong> smaller node amounts.<br />

Readiness of LON- Cabling<br />

Readiness <strong>for</strong> LON can be improved by installing<br />

a sufficient amount of LON boxes with RJ 45 female<br />

connectors to connect the nodes.<br />

LON outlets should be installed in such amounts <strong>and</strong> at<br />

such distances that a allow a readiness <strong>for</strong> LON in all<br />

premises can be achieved.<br />

The type of cable used as a connecting wire <strong>and</strong> its lenght<br />

should be chosen according to the tranceivers <strong>and</strong> in<br />

compliance with the allowed lengths of cable <strong>and</strong><br />

distances between nodes.<br />

Cabling implemented in the right way is a basic<br />

prerequisite <strong>for</strong> error-free <strong>and</strong> reliable data transmission<br />

between intelligent nodes. Cabling has a great effect on<br />

how the LON network will serve its users in the future when<br />

it is need to change <strong>and</strong> grow.<br />

Implementation of LON- Cabling<br />

LON-pair<br />

0,65 mm cable<br />

1 2 3 4 5 6 7 8<br />

Connection cable<br />

RJ 45 - screw connection<br />

LON CABLING<br />

57


SIGNAL CABLES<br />

58<br />

Buil ding au to ma ti on cab le<br />

LO NAK 2 x 1,3 <strong>and</strong> LONAK ARM 2 x 1,3<br />

AP PLI CA TIONS<br />

— LONAK: Fixed in door — LONAK ARM: Outdoor<br />

in stal la tions installations<br />

— LON net ca bling — Build ing auto ma tion<br />

ca bling<br />

De signed spe cially <strong>for</strong> LON net work ca bling sys tems.<br />

Maxi mum ambient tem pera ture:<br />

- in operation +70 °C<br />

Low est rec om mended installation<br />

tem pera ture: –5 °C<br />

CON STRUC TION<br />

LONAK 2 x 1,3<br />

Con duc tor Str<strong>and</strong>ed tinned cop per<br />

In su la tion PVC<br />

Unit Twisted pair<br />

Sheath Grey LINYL- PVC<br />

Sheath NK CABLES LO NAK 2 x 1,3<br />

mark ing trace abil ity code, me tre mark ing<br />

CA BLE SIZES<br />

Num ber <strong>and</strong> size of<br />

the con duc tors mm 2 2 x 1,3 2 x 1,3<br />

EAN code (SSTL code) 64 100+ 02 649 20-8 02 649 30-7<br />

Nomi nal di ame ter mm 7,0 10,5<br />

Mass kg/km 65 155<br />

De liv ery length m 1000 1000<br />

ELEC TRI CAL PROP ER TIES 20 °C<br />

Maxi mum loop re sis tance Ω/km 28 28<br />

Nomi nal mu tual ca paci tance nF/km 72 72<br />

Nomi nal im ped ance Ω 82<br />

Mini mum rec om mended bend ing ra dius:<br />

- dur ing in stal la tion 15xD<br />

- during operation 10xD<br />

Maxi mum per mis si ble ten sile stress<br />

dur ing in stal la tion: 130 N<br />

IDEN TI FI CA TION<br />

a- conductor is white, b- conductor is blue<br />

The LONAK ca ble fulfils the fire con di tion re quire ments<br />

of IEC 332-1.<br />

LONAK ARM 2 x 1,3<br />

Con duc tor Str<strong>and</strong>ed tinned cop per<br />

In su la tion PE<br />

Unit Twisted pair<br />

Sheath Grey PVC<br />

Ar mour ing Heli cally wrapped steel b<strong>and</strong>s<br />

Outersheath Black PE<br />

Mini mum in su la tion re sis tance MΩ x km 100 100<br />

Veloci ty fac tor 0,55 0,55<br />

Maxi mum volt age V 75 75<br />

LO NAK is also available as halo gen free LONAK- HF ver sion. LO NAK ARM is also available as halo gen free LO NAK ARM- HF ver sion.<br />

N


AP PLI CA TIONS<br />

Buil ding au to ma ti on cab le<br />

LO NAK 2 x 2 x 0,8 <strong>and</strong><br />

LONAK 2 x 2 x 0,65<br />

— 2 x 2 x 0,8: Fixed in door — 2 x 2 x 0,65: Outin<br />

stal la tions door installations<br />

— LON net ca bling — Build ing auto ma tion<br />

ca bling<br />

De signed spe cially <strong>for</strong> LON net work ca bling sys tems.<br />

Maxi mum ambient tem pera ture:<br />

- in operation +70 °C<br />

Low est rec om mended installation<br />

tem pera ture: –5 °C<br />

Mini mum rec om mended bend ing ra dius:<br />

- dur ing in stal la tion 15xD<br />

- during operation 10xD<br />

CON STRUC TION<br />

LONAK 2 x 2 x 0,8<br />

Con duc tor Tinned cop per<br />

In su la tion PVC<br />

Unit Twisted pair<br />

Shield Aluminium tape <strong>and</strong> earth conductor<br />

Sheath Grey LINYL- PVC<br />

CA BLE SIZES<br />

LO NAK 2 x 2 x 0,8 is also available as halo gen free LONAK- HF ver sion.<br />

Maxi mum per mis si ble ten sile stress<br />

dur ing in stal la tion:<br />

2 x 2 x 0,8 100 N<br />

2 x 2 x 0,65 65 N<br />

IDEN TI FI CA TION<br />

Pair Con duc tor<br />

1 white / blue<br />

2 white / orange<br />

The ca ble fulfils the fire con di tion re quire ments of<br />

IEC 332-1.<br />

LONAK 2 x 2 x 0,65<br />

Con duc tor Tinned cop per<br />

In su la tion PE<br />

Unit Twisted pair<br />

Shield Alu min ium tape <strong>and</strong> earth con duc tor<br />

Sheath Grey LINYL- PVC<br />

Num ber <strong>and</strong> diameter of<br />

the con duc tors mm 2 x 2 x 0,8 2 x 2 x 0,65<br />

EAN code (SSTL code) 64 100+ 02 649 38-3 02 649 36-9<br />

Nomi nal di ame ter mm 6,5 4,5<br />

Mass kg/km 58 32<br />

De liv ery length m 1000 1000<br />

ELEC TRI CAL PROP ER TIES 20 °C<br />

Maxi mum loop re sis tance Ω/km 73 106<br />

Nomi nal mu tual ca paci tance nF/km 98 49<br />

Mini mum in su la tion re sis tance MΩ x km 100 100<br />

Ve loc ity fac tor 0,55 0,67<br />

Re sis tance un bal ance, max % 3<br />

Max. ca paci tance un bal ance pF/m 1600<br />

Maxi mum volt age V 75 75<br />

N<br />

SIGNAL CABLES<br />

The right to al tera tions re served.<br />

59


SIGNAL CABLES<br />

60<br />

AP PLI CA TIONS<br />

— Fixed in door — Alarm, sig nal <strong>and</strong><br />

in stal la tions se cu rity con trol<br />

— Build ing auto ma tion trans mis sion<br />

Maxi mum ambient tem pera ture:<br />

- in operation +70 °C<br />

Low est rec om mended installation<br />

tem pera ture: –5 °C<br />

Mini mum rec om mended bend ing ra dius:<br />

- dur ing in stal la tion 15xD<br />

- during operation 10xD<br />

CON STRUC TION<br />

Ac cord ing to SFS 2751<br />

Con duc tor Tinned cop per<br />

In su la tion PVC<br />

CA BLE SIZES<br />

Sig nal cab le<br />

KLM<br />

Unit In su lated con duc tors twisted to gether<br />

Sheath Grey LINYL- PVC<br />

Num ber <strong>and</strong> di ame ter of<br />

the con duc tors mm 2 x 0,8 4 x 0,8<br />

EAN code (SSTL code) 64 100+ 02 910 01-8 02 910 03-2<br />

Nomi nal di ame ters mm 4,5 5,0<br />

Mass kg/km 25 40<br />

De liv ery length m 500 500<br />

ELEC TRI CAL PROP ER TIES 20 °C<br />

Maxi mum con duc tor re sis tance Ω/km 36,7<br />

Mini mum in su la tion re sis tance MΩ x km 500<br />

Maxi mum volt age V 75<br />

KLM is also available as halo gen free KLM- HF ver sion.<br />

IDEN TI FI CA TION<br />

1. Conductor blue<br />

2. Conductor yel low<br />

3. Conductor white<br />

4. Conductor red<br />

The ca ble fulfils the fire con di tion re quire ments of<br />

IEC 332-1.


AP PLI CA TIONS<br />

— Fixed in door — Alarm, sig nal <strong>and</strong><br />

in stal la tions se cu rity con trol<br />

— Build ing auto ma tion trans mis sion<br />

Maxi mum ambient tem pera ture:<br />

- in operation +70 °C<br />

Low est rec om mended installation<br />

tem pera ture: –5 °C<br />

Mini mum rec om mended bend ing ra dius:<br />

- dur ing in stal la tion 15xD<br />

- during operation 10xD<br />

CON STRUC TION<br />

Ac cord ing to SFS 2755<br />

Con duc tor Tinned cop per<br />

In su la tion PVC<br />

CA BLE SIZES<br />

Sig nal cab le<br />

KLMA<br />

Num ber <strong>and</strong> di ame ter of<br />

the con duc tors mm 2 x 0,8+0,8 4 x 0,8+0,8<br />

EAN code (STTL code) 64 100+ 02 920 01-7 02 920 03-1<br />

Nomi nal di ame ters mm 4,5 5,0<br />

Mass kg/km 30 45<br />

De liv ery length m 500 500<br />

ELEC TRI CAL PROP ER TIES 20 °C<br />

Maxi mum con duc tor re sis tance Ω/km 36,7<br />

Mini mum in su la tion re sis tance MΩ x km 500<br />

Maxi mum volt age V 75<br />

KLMA is also available as halo gen free KLMA- HF ver sion.<br />

IDEN TI FI CA TION<br />

1. Conductor blue<br />

2. Conductor yel low<br />

3. Conductor white<br />

4. Conductor red<br />

SIG NAL CA BLES<br />

The ca ble fulfils the fire con di tion re quire ments of<br />

IEC 332-1.<br />

Unit Twisted con duc tors shielded with<br />

plas tic-alu min ium tape, earth con duc tor<br />

Sheath Grey LINYL- PVC<br />

The right to al tera tions re served.<br />

61


SIG NAL CA BLES<br />

62<br />

AP PLI CA TIONS<br />

— Fixed in door — Alarm, sig nal <strong>and</strong><br />

in stal la tions se cu rity con trol<br />

— Build ing auto ma tion trans mis sion<br />

Maxi mum ambient tem pera ture:<br />

- in operation +70 °C<br />

Low est rec om mended installation<br />

tem pera ture: –5 °C<br />

Mini mum rec om mended bend ing ra dius:<br />

- dur ing in stal la tion 15xD<br />

- during operation 10xD<br />

CON STRUC TION<br />

Ac cord ing to SFS 2752<br />

Con duc tor Tinned cop per<br />

In su la tion PVC<br />

CA BLE SIZES<br />

Fire alarm cab le<br />

MMSA<br />

IDEN TI FI CA TION<br />

Num ber<br />

in con cen tric<br />

layer<br />

1<br />

2, 5, 8 ...<br />

3, 6, 9...<br />

4, 7, 10<br />

last<br />

Con duc tors Str<strong>and</strong> ing<br />

Col our Type Make- up<br />

Blue<br />

(mark col our)<br />

yellow<br />

white<br />

brown<br />

red<br />

(direction<br />

indication)<br />

Num ber <strong>and</strong> di ame ter of<br />

the con duc tors mm 4 x 0,8+0,8 12 x 0,8+0,8 20 x 0,8+0,8<br />

EAN code (SSTL code) 64 100+ 02 630 70-1 02 630 72-5 02 630 74-9<br />

Nomi nal di ame ters mm 5,5 8,5 10,0<br />

Mass kg/km 45 115 180<br />

De liv ery length m 1000 1000 1000<br />

ELEC TRI CAL PROP ER TIES 20 °C<br />

Maxi mum con duc tor re sis tance Ω/km 36,7<br />

Mini mum in su la tion re sis tance MΩ x km 500<br />

Maxi mum volt age V 75<br />

4x<br />

12x<br />

20x<br />

0+4<br />

3+9<br />

1+7+12<br />

The ca ble fulfils the fire con di tion re quire ments of<br />

IEC 332-1.<br />

Earth shield Aluminium tape on insulated conductor<br />

Str<strong>and</strong>ing Twisted con duc tors, earth con duc tor<br />

Sheath Grey LINYL- PVC<br />

The right to al tera tions re served.


AP PLI CA TIONS<br />

— Fixed outdoor — Alarm, sig nal <strong>and</strong><br />

in stal la tions se cu rity con trol<br />

— Build ing auto ma tion trans mis sion<br />

Maxi mum ambient tem pera ture:<br />

- in operation +70 °C<br />

Low est rec om mended installation<br />

tem pera ture: –5 °C<br />

Mini mum rec om mended bend ing ra dius:<br />

- dur ing in stal la tion 15xD<br />

- during operation 10xD<br />

CON STRUC TION<br />

Ac cord ing to SFS 2752<br />

Con duc tor Tinned cop per<br />

In su la tion PVC<br />

Earth shield Aluminium tape on insulated conductor<br />

CA BLE SIZES<br />

Fire alarm cab le<br />

MMVDMA (MMPMA)<br />

IDEN TI FI CA TION<br />

Num ber<br />

in con cen tric<br />

layer<br />

1<br />

2, 5, 8 ...<br />

3, 6, 9...<br />

4, 7, 10<br />

last<br />

Con duc tors Str<strong>and</strong> ing<br />

Col our Type Make- up<br />

Blue<br />

(mark colour)<br />

yellow<br />

white<br />

brown<br />

red<br />

(direction<br />

indication)<br />

Str<strong>and</strong>ing Twisted con duc tors, earth con duc tor<br />

Sheath Grey LINYL- PVC<br />

Ar mour ing Steel wire ar mour ing<br />

Outersheath Black PVC<br />

Num ber <strong>and</strong> di ame ter of<br />

con duc tors mm 4 x 0,8+0,8 12 x 0,8+0,8 20 x 0,8+0,8<br />

EAN code (SSTL code) 64 100+ 02 633 00-9 02 633 02-3 02 633 04-7<br />

Nomi nal di ame ters mm 11,5 15,0 17,5<br />

Mass kg/km 230 390 520<br />

De liv ery length m 1000 1000 1000<br />

ELEC TRI CAL PROP ER TIES 20 °C<br />

MMVDMA<br />

MMPMA<br />

Maxi mum con duc tor re sis tance Ω/km 36,7<br />

Mini mum in su la tion re sis tance MΩ x km 500<br />

Maxi mum volt age V 75<br />

SIGNAL CA BLES<br />

4x<br />

12x<br />

20x<br />

0+4<br />

3+9<br />

1+7+12<br />

The right to al tera tions re served.<br />

63


DATA CA BLES<br />

64<br />

GEN ERAL<br />

GE NE RIC CAB LING SYS TEMS<br />

Generic cabling is applied to telecommunication cabling<br />

as a permanent part of the office to meet the exp<strong>and</strong>ing<br />

needs of the user’s. It meets also the future data<br />

transmission requirements including new computers <strong>and</strong><br />

relocation of the workstations on the premises<br />

- minimizing the need <strong>for</strong> new cabling.<br />

The physical structure of a generic cabling system is<br />

star-shaped. This makes the network control easier which<br />

is important especially now when the telecommunication<br />

<strong>and</strong> data networks in buildings are the property of<br />

the owner. A star-shape cable system allows to change<br />

the network topology from the cross-connection to a bus<br />

or a ring. In a star-shape system all the active components<br />

can be placed together in one space which is easy to<br />

control <strong>and</strong> can be locked <strong>and</strong> which improves data<br />

security. Also measurements <strong>and</strong> maintenance are easier<br />

to carry out in the cross-connection area. lf one branch of<br />

the star network falls off the whole system is not paralyzed<br />

because the faulty branch can be disconnected from the<br />

network.<br />

The generic cabling system is not really open until its<br />

components are vendorindependent. They just have to<br />

con<strong>for</strong>m to the st<strong>and</strong>ards. When planning a cable system<br />

it is important to consider what the openness really means<br />

<strong>and</strong> how open the non-compatible <strong>and</strong> vendor-dependent<br />

cable systems are.<br />

STAN DARDS<br />

The European st<strong>and</strong>ard <strong>for</strong> the generic cabling systems<br />

is EN 50173 which was set up on the basis of the<br />

international ISO/IEC 11801. The corresponding st<strong>and</strong>ard<br />

in the U.S. is ANSI/TIA/EIA 568-A supported by TIA <strong>and</strong><br />

EIA. The EN 50173 applicable in Europe defines the<br />

different transmission line applications <strong>and</strong> classes as well<br />

as the categories 3 <strong>and</strong> 5 <strong>for</strong> the line components.<br />

For example, a data network that fulfills the requirements<br />

of class D can be set up from components of category 5.<br />

EN 50173 recommends the use of 100 Ω twisted-pair<br />

cables in horizontal cabling.<br />

Cat. 6 st<strong>and</strong>ard will be ready in 2001.<br />

SCREENING<br />

The abbreviations UTP, FTP <strong>and</strong> STP-screening<br />

construction are used to refer to the cable. UTP is a cable<br />

where symmetrical twisted pairs are used <strong>for</strong> screening.<br />

A FTP cable has an overall metal shield, <strong>and</strong> in a STP<br />

cable all the pairs are screened separately. The cable type<br />

is chosen to suit the environment where it’s used.<br />

In Finl<strong>and</strong> most of the installations are made with FTP <strong>and</strong><br />

UTP cables. Optical fibre cables are recommended <strong>for</strong><br />

local <strong>and</strong> rising cabling.<br />

The STP may also be marked ScTP <strong>and</strong> S/STP, meaning<br />

a construction with a pair <strong>and</strong> an overall shield.<br />

AP PLI CA TION AND TRANS MIS SION<br />

CLASSES<br />

Transmission<br />

classes<br />

A<br />

B<br />

C<br />

D<br />

Application Maximum<br />

frequency<br />

Voice b<strong>and</strong> <strong>and</strong><br />

low-frequency<br />

applications<br />

100 kHz<br />

Medium-speed<br />

data applications 1 MHz<br />

Fast data<br />

applications 16 MHz<br />

Very fast data<br />

applications 100 MHz<br />

E Very fast data<br />

applications 200 MHz<br />

OPTICAL<br />

Very fast data<br />

applications<br />

A ge neric ca bling sys tem con structed <strong>for</strong> a cer tain<br />

ap pli ca tion con sists of one or sev eral trans mis sion lines.<br />

REC OM MEN DA TIONS<br />

— It is important to examine the building needs very<br />

carefully, including e.g. the existing network <strong>and</strong><br />

the desires <strong>for</strong> more extended data transmission<br />

in the future.<br />

— The maximum length of horizontal cabling is 90 m.<br />

The maximum length of cross-connection <strong>and</strong><br />

equipment cabling is 10 m.<br />

— An optical fibre cable is recommended <strong>for</strong> local <strong>and</strong><br />

rising cabling.<br />

— Two double cables should be installed <strong>for</strong> each work<br />

area, in order to meet the increasing need of<br />

telecommunication.<br />

DATA TRANSMISSION CABLES<br />

Our complete range of UC cables fulfills tomorrow’s<br />

needs. Our new product family UC 400 is designed <strong>for</strong><br />

applications beyond CAT 5 with good properties.<br />

Our new development <strong>for</strong> the high-end field is UC 1000.<br />

A cable class that not only fulfills the above mentioned<br />

st<strong>and</strong>ards, but also offers reserves, allowing base b<strong>and</strong><br />

transmission of Gigabit-Ethernet.<br />

_


GE NERIC CA BLING CON STRUC TION<br />

Building distributor<br />

Building backbone cabling<br />

Floor distributor<br />

Horizontal cabling<br />

FD<br />

Telecommunication outlets<br />

CONTENTS<br />

Campus distributor<br />

Campus backbone cabling<br />

CD<br />

BD BD<br />

BD<br />

FD FD<br />

TO TO TO TO TO TO<br />

ATM<br />

DATA CA BLES<br />

FD<br />

ATM, or the Asynchronous Transfer Mode, is a network<br />

technology which use is very rapidly increasing. ATM can<br />

be used to transfer sound, picture <strong>and</strong> data. ATM is based<br />

on data transfer with cells of the same size which reserve<br />

the line only <strong>for</strong> the duration of the actual transmission.<br />

MEAN ING OF THE SYM BOLS<br />

UC = Uni ver sal Ca ble<br />

300 = Maxi mum fre quency 300 MHz,<br />

fast data ap pli ca tions<br />

400, 600 = Maxi mum fre quency 400, 600 MHz,<br />

fast data ap pli ca tions<br />

S = Screen alu min ium shield<br />

D = Dou ble<br />

SS = Su per Screen pair foil screen<br />

with com mon braid<br />

24 = AWG- number<br />

di ame ter of con duc tor 0,51 mm<br />

22 = AWG- number<br />

di ame ter of con duc tor 0,64 mm<br />

4 P = four pair<br />

2 x 4 P = Dou ble<br />

FRNC = Halogen- free ma te rial<br />

Ex am ple. UC 300 D S 24 2x4 P<br />

UC = Uni ver sal Ca ble,<br />

300 = Maxi mum fre quency 300 MHz,<br />

fast data ap pli ca tions<br />

D = Dou ble<br />

S = Screen alu min ium shield<br />

24 = AWG- number<br />

di ame ter of con duc tor 0,51 mm<br />

2 x 4 P = Dou ble<br />

65


DATA CA BLES<br />

66<br />

GE NERIC CA BLING CA BLE TYPE<br />

HORIZONTAL<br />

CABLING<br />

BUILDING<br />

BACKBONE<br />

CABLING<br />

Cable type<br />

THE COL OUR SYS TEM OF THE<br />

CON DUC TORS<br />

NK Ca bles rec om mend that the con duc tors of UC 300<br />

ca bles could be con nected as fol lows:<br />

Pair a b<br />

1 white blue<br />

2 white or ange<br />

3 white green<br />

4 white brown<br />

On the a-wire there is a stripe of the same colour as<br />

the corresponding b-wire.<br />

Design/protection against<br />

electromagnetic<br />

disturbancies<br />

UC 300 S 24 4P FTP<br />

Overall shield 100/125<br />

UC 300 DS 24 2 x 4P FTP<br />

Overall shield<br />

Shotgun version<br />

UC 300 24 4P UTP<br />

UC 300 D 24 2 x 4P UTP<br />

Shotgun version<br />

UC 400 24 4P<br />

High<br />

Per<strong>for</strong>mance UTP<br />

UC 400 D 24 2 x 4P High<br />

Per<strong>for</strong>mance UTP<br />

Shotgun version<br />

UC 400 S 24 2 x 4P<br />

High<br />

Per<strong>for</strong>mance FTP<br />

UC 400 DS 24 2 x 4P High<br />

Per<strong>for</strong>mance FTP<br />

Shotgun version<br />

Frequency, max. MHz Classification<br />

EN 50173<br />

100/125<br />

200/250<br />

200/250<br />

UC 600 SS 23 4P Overall shield<br />

Screened pair 600<br />

UC 1000 SS 22 4P<br />

FYMSU n x 62.5/125<br />

(Spiral Space ® )<br />

S/STP<br />

Fibre optic cable<br />

CONTENTS<br />

1000<br />

Category 5/5e<br />

Category 5/5e<br />

Category 5/5e<br />

Category 5/5e<br />

Cat 6<br />

Cat 6<br />

Cat 7<br />

Application<br />

Telephone network<br />

ISDN<br />

Ethernet 10, 100 Mbit/s<br />

Token Ring 4/16 Mbit/s<br />

CDDI /TP-PMD<br />

ATM<br />

Tele phone net work<br />

ISDN<br />

Eth er net 100 Mbit/s<br />

To ken Ring 4/16 Mbit/s<br />

CDDI /TP- PMD<br />

ATM<br />

Tele phone net work<br />

ISDN<br />

Eth er net 100 Mbit/s<br />

To ken Ring 4/16 Mbit/s<br />

CDDI /TP- PMD<br />

ATM<br />

Gigabit-Ethernet<br />

Tele phone net work<br />

ISDN<br />

Eth er net 100 Mbit/s<br />

To ken Ring 4/16 Mbit/s<br />

CDDI /TP- PMD<br />

ATM<br />

Gigabit-Ethernet<br />

Tele phone net work<br />

ISDN<br />

Eth er net 100 Mbit/s<br />

To ken Ring 4/16 Mbit/s<br />

CDDI /TP- PMD<br />

ATM<br />

Gigabit-Ethernet<br />

ISDN<br />

Ethernet 10 Mbit/s<br />

Token Ring 4/16 Mbit/s<br />

CDDI /TP-PMD<br />

ATM<br />

Gigabit-Ethernet<br />

The stan dard does not de fine the col our sys tems but, <strong>for</strong><br />

rea sons of con <strong>for</strong> mity, the above sys tem is rec om mended.


CONTENTS<br />

All these new UC- cables have been tested by the EC group of Delta, <strong>and</strong> here is an example of a statement on UC 300 S.<br />

DATA CA BLES<br />

67


DATA CA BLES<br />

68<br />

Data cab le, category 5, FTP<br />

UC 300 S 24 4P / UC 300 DS 24 2 x 4P<br />

N<br />

AP PLI CA TIONS<br />

— Fixed in door — Eth er net 100 Mbit/s<br />

in stal la tions — To ken Ring 4/16 Mbit/s<br />

— CDDI — Tele phone net works<br />

— TP- PMD — ISDN<br />

— ATM — Ge neric ca bling sys tem<br />

Maxi mum ambient tem pera ture:<br />

- in operation +70 °C<br />

Low est rec om mended installation<br />

tem pera ture: –5 °C<br />

Mini mum rec om mended bend ing ra dius:<br />

- dur ing in stal la tion 10xD<br />

- during operation 5xD<br />

Maxi mum per mis si ble ten sile stress<br />

dur ing in stal la tion:<br />

UC 300 S 24 4P 80 N<br />

UC 300 DS 24 2 x 4P 160 N<br />

STAN DARDS<br />

EN 50173; prEN 50288-3-1<br />

ISO/IEC 11801 2 rd ed<br />

TIA/EIA 568-A<br />

ISO 8802.3/IEEE 802.3 100 base T<br />

IDEN TI FI CA TION<br />

UC 300 S 24 4P is available as halogenfree UC 300 DS 24 2 x 4P- FRNC-B/C version.<br />

Pair Col our code Pair Col our code<br />

1 white/blue 3 white/green<br />

2 white/orange 4 white/brown<br />

On the a-wire there is a stripe of the same colour as<br />

the corresponding b-wire.<br />

The ca ble fulfils the fire con di tion re quire ments of<br />

IEC 332-1.


DATA CA BLES<br />

Data cab le,category 5, FTP<br />

UC 300 S 24 4P / UC 300 DS 24 2 x 4P<br />

CON STRUC TION<br />

Con duc tor Cop per wire, d = 0,51 mm<br />

In su la tion PE<br />

Unit Twisted pair<br />

Earth wire Tinned cop per<br />

CA BLE SIZES<br />

Type UC 300 S 24 4P UC 300 DS 24 2 x 4P<br />

EAN code (STTL code) 64 100+ 02 640 01 02 640 64<br />

Nomi nal di ame ters mm 5,8 5,8 x 11,6<br />

Mass kg/km 36 72<br />

De liv ery length m 500 500<br />

ELEC TRI CAL PROP ER TIES 20 °C<br />

Loop re sis tance, max Ω/km 176<br />

In su la tion re cis tance, min GΩ x km 2<br />

Nomi nal mu tual ca paci tance nF/km 48<br />

Maxi mum ca paci tance<br />

un bal ance, pair to ground pF/km ≤1500<br />

Nomi nal im ped ance Ω ƒ =1 - 100 MHz 100 ± 15<br />

Maxi mum trans fer im ped ance MΩ x m 100<br />

Ve loc ity fac tor 0,67<br />

Maxi mum volt age V 75<br />

TRANSMISSION CHARACTERISTICS ACC. TO CATEGORY 5e (at 20 °C)<br />

Fre quency<br />

MHz<br />

1<br />

4<br />

10<br />

16<br />

20<br />

31,2<br />

62,5<br />

100<br />

125<br />

155,5<br />

175<br />

200<br />

250<br />

300<br />

Attenuation<br />

(dB/100 m)<br />

NEXT<br />

(dB)<br />

PS-NEXT<br />

(dB)<br />

ACR<br />

(dB/100 m)<br />

PS-ACR<br />

(dB/100 m)<br />

ELFEXT<br />

(dB/100 m)<br />

PS-ELFEXT<br />

(dB/100 m)<br />

max. nom. min. nom. min. nom. min. nom. min. nom. min. nom. min. nom. min.<br />

2<br />

3,9<br />

6,3<br />

8,0<br />

9,0<br />

11,4<br />

16,5<br />

21,3<br />

1,9<br />

3,7<br />

6,0<br />

7,6<br />

8,5<br />

10,7<br />

15,7<br />

19,8<br />

22,3<br />

24,2<br />

25,7<br />

27,5<br />

29,2<br />

32,0<br />

65<br />

56<br />

50<br />

47<br />

46<br />

43<br />

38<br />

35<br />

71<br />

62<br />

56<br />

53<br />

51<br />

49<br />

40<br />

41<br />

40<br />

38<br />

37<br />

36<br />

35<br />

34<br />

62<br />

53<br />

47<br />

44<br />

43<br />

40<br />

35<br />

32<br />

68<br />

59<br />

53<br />

50<br />

48<br />

46<br />

41<br />

38<br />

37<br />

35<br />

34<br />

33<br />

32<br />

31<br />

Screen Plas tic/alu min ium tape as a over all<br />

shield<br />

Sheath Grey PVC<br />

63,3<br />

52,4<br />

44,0<br />

39,3<br />

36,8<br />

31,5<br />

21,9<br />

14,0<br />

69,1<br />

58,3<br />

50,0<br />

45,3<br />

43,0<br />

37,9<br />

28,4<br />

21,2<br />

17,2<br />

13,9<br />

11,6<br />

9,0<br />

5,8<br />

1,8<br />

60,3<br />

49,4<br />

41,0<br />

36,3<br />

33,8<br />

28,5<br />

18,9<br />

11,0<br />

66,1<br />

55,3<br />

47,0<br />

42,3<br />

40,0<br />

34,9<br />

25,4<br />

18,2<br />

14,2<br />

10,9<br />

8,6<br />

6,0<br />

2.8<br />

-1,2<br />

64<br />

52<br />

44<br />

40<br />

38<br />

34<br />

28<br />

24<br />

68<br />

56<br />

48<br />

44<br />

42<br />

38<br />

32<br />

28<br />

26<br />

24<br />

23<br />

22<br />

20<br />

16<br />

61<br />

49<br />

41<br />

37<br />

35<br />

31<br />

25<br />

21<br />

65<br />

53<br />

45<br />

41<br />

39<br />

35<br />

29<br />

25<br />

23<br />

21<br />

20<br />

19<br />

17<br />

13<br />

Return<br />

loss<br />

(dB)<br />

23<br />

23<br />

23<br />

23<br />

23<br />

23<br />

23<br />

23<br />

The right to al tera tions re served.<br />

69


DATA CA BLES<br />

70<br />

N<br />

Data cab le, category 5, UTP<br />

UC 300 24 4P / UC 300 D 24 2 x 4P<br />

AP PLI CA TIONS<br />

— Fixed in door — Eth er net 100 Mbit/s<br />

in stal la tions — To ken Ring 4/16 Mbit/s<br />

— CDDI — Tele phone net works<br />

— TP- PMD — ISDN<br />

— ATM — Ge neric ca bling sys tem<br />

Maxi mum ambient tem pera ture:<br />

- in operation +70 °C<br />

Low est rec om mended installation<br />

tem pera ture: –5 °C<br />

Mini mum rec om mended bend ing ra dius:<br />

- dur ing in stal la tion 10xD<br />

- during operation 5xD<br />

Maxi mum per mis si ble ten sile stress<br />

dur ing in stal la tion:<br />

UC 300 24 4P 80 N<br />

UC 300 D 24 2 x 4P 160 N<br />

STAN DARDS<br />

UC 300 24 4P is available as halogenfree UC 300 D 24 2 x 4P- FRNC-B/C version.<br />

EN 50173; prEN 50288-3-1<br />

ISO/IEC 11801 2 rd ed<br />

TIA/EIA 568-A<br />

ISO 8802.3/IEEE 802.3 100 base T<br />

IDEN TI FI CA TION<br />

Pair Col our code Pair Col our code<br />

1 white/blue 3 white/green<br />

2 white/orange 4 white/brown<br />

On the a-wire there is a stripe of the same colour as<br />

the corresponding b-wire.<br />

The ca ble fulfils the fire con di tion re quire ments of<br />

IEC 332-1.


Data cab le, category 5, UTP<br />

UC 300 24 4P / UC 300 D 24 2 x 4P<br />

CON STRUC TION<br />

Con duc tor Cop per wire, d = 0,51 mm<br />

In su la tion PE<br />

CA BLE SIZES<br />

Type UC 300 24 4P UC 300 D 24 2 x 4P<br />

EAN code (STTL code) 64 100+ 02 640 05 02 640 07<br />

Nomi nal di ame ters mm 5,0 5,0 x 10,0<br />

Mass kg/km 35 70<br />

De liv ery length m 500 500<br />

ELEC TRI CAL PROP ER TIES 20 °C<br />

Loop re sis tance, max Ω/km 176<br />

In su la tion re cis tance, min GΩ x km 2<br />

Nomi nal mu tual ca paci tance nF/km 48<br />

Maxi mum ca paci tance<br />

un bal ance, pair to ground pF/km ≤1500<br />

Nomi nal im ped ance Ω ƒ =1 - 100 Mhz 100 ± 15<br />

Ve loc ity fac tor 0,67<br />

Maxi mum volt age V 75<br />

TRANSMISSION CHARACTERISTICS ACC. TO CATEGORY 5e (at 20 °C)<br />

Fre quency<br />

MHz<br />

1<br />

4<br />

10<br />

16<br />

20<br />

31,2<br />

62,5<br />

100<br />

125<br />

155,5<br />

175<br />

200<br />

250<br />

300<br />

Attenuation<br />

(dB/100 m)<br />

NEXT<br />

(dB)<br />

PS-NEXT<br />

(dB)<br />

ACR<br />

(dB/100 m)<br />

PS-ACR<br />

(dB/100 m)<br />

ELFEXT<br />

(dB/100 m)<br />

DATA CA BLES<br />

PS-ELFEXT<br />

(dB/100 m)<br />

max. nom. min. nom. min. nom. min. nom. min. nom. min. nom. min. nom. min.<br />

2<br />

3,9<br />

6,3<br />

8,0<br />

9,0<br />

11,4<br />

16,5<br />

21,3<br />

1,9<br />

3,7<br />

6,0<br />

7,6<br />

8,4<br />

10,7<br />

15,7<br />

19,8<br />

22,3<br />

24,2<br />

25,7<br />

27,5<br />

29,2<br />

32,0<br />

65<br />

56<br />

50<br />

47<br />

46<br />

43<br />

38<br />

35<br />

71<br />

62<br />

56<br />

53<br />

51<br />

49<br />

44<br />

41<br />

40<br />

38<br />

37<br />

36<br />

35<br />

34<br />

62<br />

53<br />

47<br />

44<br />

43<br />

40<br />

35<br />

32<br />

68<br />

59<br />

53<br />

50<br />

48<br />

46<br />

41<br />

38<br />

37<br />

35<br />

34<br />

33<br />

32<br />

31<br />

Unit Twisted pair<br />

Sheath Grey PVC<br />

63,3<br />

52,4<br />

44,0<br />

39,3<br />

36,8<br />

31,5<br />

21,9<br />

14,0<br />

69,1<br />

58,3<br />

50,0<br />

45,3<br />

43,0<br />

37,9<br />

28,4<br />

21,2<br />

17,2<br />

13,9<br />

11,6<br />

9,0<br />

5,8<br />

1,8<br />

60,3<br />

49,4<br />

41,0<br />

36,3<br />

33,8<br />

28,5<br />

18,9<br />

11,0<br />

66,1<br />

55,3<br />

47,0<br />

42,3<br />

40,0<br />

34,9<br />

25,4<br />

18,2<br />

14,2<br />

10,9<br />

8,6<br />

6,0<br />

2,8<br />

-1,2<br />

64<br />

52<br />

44<br />

40<br />

38<br />

34<br />

28<br />

24<br />

68<br />

56<br />

48<br />

44<br />

42<br />

38<br />

32<br />

28<br />

26<br />

24<br />

23<br />

22<br />

20<br />

16<br />

61<br />

49<br />

41<br />

37<br />

35<br />

31<br />

25<br />

21<br />

65<br />

53<br />

45<br />

41<br />

39<br />

35<br />

29<br />

25<br />

23<br />

21<br />

20<br />

19<br />

17<br />

13<br />

Return<br />

loss<br />

(dB)<br />

23<br />

23<br />

23<br />

23<br />

23<br />

23<br />

23<br />

23<br />

The right to al tera tions re served.<br />

71


DATA CA BLES<br />

Data cab le, category 6, STP, Patented<br />

UC 400 S 23/1 4P/UC 400 DS 23/1 2x4P<br />

72<br />

N<br />

AP PLI CA TIONS<br />

— Fixed in door — Eth er net 10 Mbit/s, 100 Mbit/s<br />

in stal la tions — Gigabit- Ethernet<br />

— CDDI — Tele phone net works<br />

— TP- PMD — ISDN<br />

— ATM — Ge neric ca bling sys tem<br />

Maxi mum ambient tem pera ture:<br />

- in operation +70 °C<br />

Low est rec om mended installation<br />

tem pera ture: –5 °C<br />

Mini mum rec om mended bend ing ra dius:<br />

- dur ing in stal la tion 10xD<br />

- during operation 5xD<br />

Maxi mum per mis si ble ten sile stress<br />

dur ing in stal la tion:<br />

UC 400 S 23/1 4P 100 N<br />

UC 400 DS 23/1 2 x 4P 200 N<br />

STAN DARDS<br />

UC 400 S 23/1 4P is available as halogenfree UC 400 S 24 4P- FRNC-B/C version.<br />

EN 50173-1; prEN 50288-5-1<br />

ISO/IEC 11801 2 nd edition<br />

TIA/EIA 568-B<br />

ISO 8802.3/IEEE 802.3 10 base T, 100 base T<br />

ISO 8802.5/IEEE 802.5<br />

IDEN TI FI CA TION<br />

Pair Col our code Pair Col our code<br />

1 white/blue 3 white/green<br />

2 white/orange 4 white/brown<br />

The cable fulfils the fire condition requirements of<br />

IEC 332-1.<br />

Halogenfree cable fulfils the fire condition requirements<br />

of IEC 332-3


DATA CA BLES<br />

Data cab le, category 6, STP, Patented<br />

UC 400 S 23/1 4P/UC 400 DS 23/1 2x4P<br />

CON STRUC TION<br />

Conductor Copper wire, d=0,56 mm<br />

Insulation PE<br />

Unit Twisted pair<br />

CA BLE SIZES<br />

Type UC 400 S 23/1 4P UC 400 DS 23/1 2x4P<br />

EAN code (SSTL code) 64 100+ 02 640 75 02 640 76<br />

Nomi nal di ame ters mm 6,5 6,5/13,0<br />

Mass kg/km 41 82<br />

De liv ery length m 500 500<br />

ELEC TRI CAL PROP ER TIES 20 °C<br />

Loop re sis tance, max Ω/km 176<br />

In su la tion re sis tance, min GΩ x km 2<br />

Nomi nal mu tual ca paci tance nF/km 48<br />

Maxi mum ca paci tance<br />

un bal ance, pair to ground pF/km ≤1500<br />

Nomi nal im ped ance Ω ƒ =1 - 100 MHz 100 ± 15<br />

Trans fer imped ance, max mΩ/m 100<br />

Ve loc ity fac tor 0,78<br />

Maxi mum volt age V 75<br />

TRANSMISSION CHARACTERISTICS ACC. TO CATEGORY 6 (at 20 °C)<br />

Fre quency<br />

MHz<br />

1<br />

4<br />

10<br />

16<br />

20<br />

31,2<br />

62,5<br />

100<br />

125<br />

155,5<br />

175<br />

200<br />

250<br />

300<br />

400<br />

Attenuation<br />

(dB/100 m)<br />

NEXT<br />

(dB)<br />

PS-NEXT<br />

(dB)<br />

ACR<br />

(dB/100 m)<br />

PS-ACR<br />

(dB/100 m)<br />

ELFEXT<br />

(dB/100 m)<br />

PS-ELFEXT<br />

(dB/100 m)<br />

max. nom. min. nom. min. nom. min. nom. min. nom. min. nom. min. nom. min.<br />

2,2<br />

3,8<br />

6,0<br />

7,6<br />

8,5<br />

10,7<br />

15,5<br />

19,9<br />

22,5<br />

25,4<br />

27,1<br />

29,2<br />

33,0<br />

2<br />

3,8<br />

6,0<br />

7,6<br />

8,5<br />

10,7<br />

15,1<br />

19,1<br />

21,3<br />

23,8<br />

25,3<br />

27,0<br />

32,6<br />

35,7<br />

41,2<br />

74<br />

65<br />

59<br />

56<br />

55<br />

52<br />

47<br />

44<br />

43<br />

42<br />

41<br />

40<br />

38<br />

87<br />

78<br />

72<br />

69<br />

68<br />

65<br />

60<br />

57<br />

56<br />

54<br />

53<br />

53<br />

51<br />

50<br />

48<br />

71<br />

62<br />

56<br />

53<br />

52<br />

49<br />

44<br />

41<br />

40<br />

39<br />

38<br />

37<br />

35<br />

84<br />

75<br />

69<br />

66<br />

65<br />

62<br />

57<br />

54<br />

53<br />

51<br />

50<br />

50<br />

48<br />

47<br />

45<br />

Earth wire Tinned copper<br />

Screen Special wrapping of Al laminated foil<br />

Sheath Blue PVC<br />

71,8<br />

61,2<br />

53,0<br />

48,4<br />

46,5<br />

41,3<br />

31,5<br />

24,1<br />

20,5<br />

16,6<br />

13,9<br />

10,8<br />

5,0<br />

85,0<br />

74,2<br />

66,0<br />

61,3<br />

59,0<br />

54,0<br />

45,0<br />

37,9<br />

34,2<br />

30,3<br />

28,1<br />

25,5<br />

18,5<br />

14,2<br />

6,8<br />

68,8<br />

58,2<br />

50,0<br />

45,4<br />

43,5<br />

38,3<br />

28,5<br />

21,1<br />

17,5<br />

13,6<br />

10,9<br />

7,8<br />

2,0<br />

82,0<br />

71,2<br />

63,0<br />

58,3<br />

56,0<br />

51,0<br />

42,0<br />

34,9<br />

31,2<br />

27,3<br />

25,1<br />

22,5<br />

15,5<br />

11,2<br />

3,8<br />

67<br />

55<br />

47<br />

43<br />

41<br />

37<br />

31<br />

27<br />

25<br />

23<br />

22<br />

21<br />

19<br />

75<br />

75<br />

75<br />

71<br />

69<br />

65<br />

59<br />

55<br />

53<br />

51<br />

50<br />

49<br />

47<br />

45<br />

53<br />

64<br />

52<br />

44<br />

40<br />

38<br />

34<br />

28<br />

24<br />

22<br />

20<br />

19<br />

18<br />

16<br />

72<br />

72<br />

72<br />

68<br />

66<br />

62<br />

56<br />

52<br />

50<br />

48<br />

47<br />

46<br />

44<br />

42<br />

40<br />

Return<br />

loss<br />

(dB)<br />

23<br />

23<br />

23<br />

23<br />

23<br />

23<br />

23<br />

23<br />

21<br />

21<br />

21<br />

21<br />

19<br />

The right to al tera tions re served.<br />

73


DATA CA BLES<br />

74<br />

N<br />

Data cab le, category 6, UTP (4 x 2 x 0,56 / AWG 23)<br />

UC 400 24 4P/UC 400 D 24 2 x 4P<br />

AP PLI CA TIONS<br />

— Fixed in door — Eth er net 10 Mbit/s, 100 Mbit/s<br />

in stal la tions — Gigabit- Ethernet<br />

— CDDI — Tele phone net works<br />

— TP- PMD — ISDN<br />

— ATM — Ge neric ca bling sys tem<br />

Maxi mum ambient tem pera ture:<br />

- in operation +70 °C<br />

Low est rec om mended installation<br />

tem pera ture: –5 °C<br />

Mini mum rec om mended bend ing ra dius:<br />

- dur ing in stal la tion 10xD<br />

- during operation 5xD<br />

Maxi mum per mis si ble ten sile stress<br />

dur ing in stal la tion:<br />

UC 400 24 4P 80 N<br />

UC 400 D 24 2 x 4P 160 N<br />

STAN DARDS<br />

UC 400 24 4P is available as halogenfree UC 400 D 24 2 x 4P- FRNC-B/C version.<br />

EN 50173; prEN 50288-6-1<br />

ISO/IEC 11801 2 nd edition<br />

TIA/EIA 568-A<br />

ISO 8802.3/IEEE 802.3 10 base T, 100 base T<br />

ISO 8802.5/IEEE 802.5<br />

IDEN TI FI CA TION<br />

Pair Col our code Pair Col our code<br />

1 white/blue 3 white/green<br />

2 white/orange 4 white/brown<br />

The cable fulfils the fire condition requirements of<br />

IEC 332-1.<br />

Halogenfree cable fulfils the fire condition requirements<br />

of IEC 332-3


CA BLE SIZES<br />

Data cab le, category 6, UTP (4 x 2 x 0,56 / AWG 23)<br />

UC 400 24 4P/UC 400 D 24 2 x 4P<br />

CON STRUC TION<br />

Conductor Copper wire, d=0,56 mm<br />

Insulation PE<br />

Type UC 400 24 4P UC 400 D 24 2 x 4P<br />

EAN code (SSTL code) 64 100+ 02 640 71 02 640 72<br />

Nomi nal di ame ters mm 5,2 5,2/10,4<br />

Mass kg/km 35 70<br />

De liv ery length m 500 500<br />

ELEC TRI CAL PROP ER TIES 20 °C<br />

Loop re sis tance, max Ω/km 176<br />

In su la tion re sis tance, min GΩ x km 2<br />

Nomi nal mu tual ca paci tance nF/km 48<br />

Maxi mum ca paci tance<br />

un bal ance, pair to ground pF/km ≤1500<br />

Nomi nal im ped ance Ω ƒ =1 - 100 MHz 100 ± 15<br />

Ve loc ity fac tor 0,78<br />

Maxi mum volt age V 75<br />

TRANSMISSION CHARACTERISTICS ACC. TO CATEGORY 6 (at 20 °C)<br />

Fre quency<br />

MHz<br />

1<br />

4<br />

10<br />

16<br />

20<br />

31,2<br />

62,5<br />

100<br />

125<br />

155,5<br />

175<br />

200<br />

250<br />

300<br />

400<br />

Attenuation<br />

(dB/100 m)<br />

NEXT<br />

(dB)<br />

PS-NEXT<br />

(dB)<br />

ACR<br />

(dB/100 m)<br />

PS-ACR<br />

(dB/100 m)<br />

ELFEXT<br />

(dB/100 m)<br />

DATA CA BLES<br />

PS-ELFEXT<br />

(dB/100 m)<br />

max. nom. min. nom. min. nom. min. nom. min. nom. min. nom. min. nom. min.<br />

2,0<br />

3,8<br />

6,0<br />

7,6<br />

8,5<br />

10,7<br />

15,5<br />

19,9<br />

22,5<br />

25,4<br />

27,1<br />

29,2<br />

33,0<br />

1,9<br />

3,8<br />

6,0<br />

7,6<br />

8,5<br />

10,7<br />

15,1<br />

19,1<br />

21,3<br />

23,8<br />

25,3<br />

27,0<br />

33,0<br />

36,1<br />

41,7<br />

74<br />

65<br />

59<br />

56<br />

55<br />

52<br />

47<br />

44<br />

43<br />

42<br />

41<br />

40<br />

38<br />

78<br />

69<br />

63<br />

60<br />

59<br />

56<br />

51<br />

48<br />

47<br />

45<br />

44<br />

44<br />

42<br />

41<br />

39<br />

71<br />

62<br />

56<br />

53<br />

52<br />

49<br />

44<br />

41<br />

40<br />

39<br />

38<br />

37<br />

36<br />

75<br />

66<br />

60<br />

57<br />

56<br />

53<br />

48<br />

45<br />

44<br />

42<br />

41<br />

41<br />

39<br />

38<br />

36<br />

Unit Twisted pair<br />

Sheath Blue PVC<br />

72,0<br />

61,2<br />

53,0<br />

48,4<br />

46,5<br />

41,3<br />

31,5<br />

24,1<br />

20,5<br />

16,6<br />

13,9<br />

10,8<br />

5,0<br />

76,1<br />

65,2<br />

57,0<br />

52,3<br />

50,0<br />

45,0<br />

36,0<br />

28,9<br />

25,2<br />

21,3<br />

19,1<br />

16,5<br />

9,1<br />

4,8<br />

-2,7<br />

69,0<br />

58,2<br />

50,0<br />

45,4<br />

43,5<br />

38,3<br />

28,5<br />

21,1<br />

17,5<br />

13,6<br />

10,9<br />

7,8<br />

2,0<br />

73,1<br />

62,2<br />

54,0<br />

49,3<br />

47,0<br />

42,0<br />

33,0<br />

25,9<br />

22,2<br />

18,3<br />

16,1<br />

13,5<br />

6,1<br />

1,8<br />

-5,7<br />

67<br />

55<br />

47<br />

43<br />

41<br />

37<br />

31<br />

27<br />

25<br />

23<br />

22<br />

21<br />

20<br />

82<br />

70<br />

62<br />

58<br />

56<br />

52<br />

46<br />

42<br />

40<br />

38<br />

37<br />

36<br />

34<br />

32<br />

30<br />

65<br />

53<br />

45<br />

41<br />

39<br />

35<br />

29<br />

25<br />

23<br />

21<br />

20<br />

19<br />

17<br />

80<br />

68<br />

60<br />

56<br />

54<br />

50<br />

44<br />

40<br />

38<br />

36<br />

35<br />

34<br />

32<br />

30<br />

28<br />

Return<br />

loss<br />

(dB)<br />

23<br />

23<br />

23<br />

23<br />

23<br />

23<br />

23<br />

23<br />

21<br />

18,8<br />

18,4<br />

18,0<br />

17,3<br />

The right to al tera tions re served.<br />

75


DATA CA BLES<br />

76<br />

N<br />

Data cab le, category 7, STP<br />

UC 600 SS 23/1 4P FRNC <strong>and</strong><br />

UC 1200 SS 22 4P FRNC<br />

AP PLI CA TIONS<br />

— Fixed in door — Eth er net 100 Mbit/s<br />

in stal la tions — Gigabit-Ethernet<br />

— FDDI — Tele phone net works<br />

— TP- PMD — ISDN<br />

— ATM — Ge neric ca bling sys tem<br />

Maxi mum ambient tem pera ture:<br />

- in operation +70 °C<br />

Low est rec om mended installation<br />

tem pera ture: –5 °C<br />

Mini mum rec om mended bend ing ra dius:<br />

- dur ing in stal la tion 10xD<br />

- during operation 5xD<br />

Maxi mum per mis si ble ten sile stress<br />

dur ing in stal la tion<br />

UC 600 340 N<br />

UC 1000 370 N<br />

CON STRUC TION<br />

UC 600 SS 23/1 4P FRNC-B<br />

Con duc tor Str<strong>and</strong>ed tinned cop per, d = 0,56 mm<br />

In su la tion PE<br />

Unit Twisted pair with alu min ium tape<br />

Earth Tin ned cop per con duc tor<br />

Shield Cop per wire braid as a com mon shield<br />

Sheath Or ange, halogen- free ma te rial<br />

Struc ture PVC- sheath also.<br />

STAN DARDS<br />

EIA/TIA 568A; TSB 36<br />

ISO/IEC 11801 2 nd ed.; JTC1 SC25 WG3 N552<br />

EN 50173; prEN 50288-4-1<br />

IDEN TI FI CA TION<br />

Pair Col our code Pair Col our code<br />

1 white/blue 3 white/green<br />

2 white/orange 4 white/brown<br />

The ca ble fulfils the fire con di tion re quire ments of<br />

IEC 332-3.<br />

Halogen free ca bles have bet ter fire re sis tant prop er ties.<br />

UC 1200 SS 22 4P FRNC-B<br />

Con duc tor Str<strong>and</strong>ed tinned cop per, d = 0,64 mm<br />

In su la tion PE<br />

Unit Twisted pair with alu min ium tape<br />

Earth Tin ned cop per con duc tor<br />

Shield Cop per wire braid as a com mon shield<br />

Sheath UC 1000 Yellow, halogen-free material<br />

The right to al tera tions re served.


CA BLE SIZES<br />

Type UC 600 SS 23/1 4P UC 1200 SS 22 4P<br />

EAN code (SSTL code) 64 100+ 02 640 56 02 640 91<br />

Nomi nal di ame ters mm 7,5 8,9<br />

Mass kg/km 75 90<br />

De liv ery length m 500 500<br />

ELEC TRI CAL PROP ER TIES 20 °C<br />

Data cab le, category 7, STP<br />

UC 600 SS 23/1 4P FRNC <strong>and</strong><br />

UC 1200 SS 22 4P FRNC<br />

Loop re sis tance, max Ω/km 165 130<br />

In su la tion re sis tance, min GΩ x km 2 2<br />

Nomi nal mu tual ca paci tance nF/km 43 43<br />

Maxi mum ca paci tance<br />

un bal ance, pair to ground pF/km ≤1200 ≤1200<br />

DATA CA BLES<br />

Nomi nal im ped ance Ω ƒ =1 - 100 MHz 100 ± 15 ƒ =1 - 100 MHz 100 ± 15<br />

Trans fer imped ance, max mΩ/m 100 100<br />

Ve loc ity fac tor 0,78 0,80<br />

Maxi mum volt age V 75 75<br />

UC 600 SS 23/1 4P FRNC: TRANSMISSION CHARACTERUSTICS ACC. TO CATEGORY 7 (at 20 °C)<br />

Fre quency<br />

MHz<br />

1<br />

4<br />

10<br />

16<br />

20<br />

31,2<br />

62,5<br />

100<br />

125<br />

155,5<br />

175<br />

200<br />

250<br />

300<br />

450<br />

600<br />

750<br />

Attenuation<br />

(dB/100 m)<br />

NEXT<br />

(dB)<br />

PS-NEXT<br />

(dB)<br />

ACR<br />

(dB/100 m)<br />

PS-ACR<br />

(dB/100 m)<br />

ELFEXT<br />

(dB/100 m)<br />

PS-ELFEXT<br />

(dB/100 m)<br />

max. nom. min. nom. min. nom. min. nom. min. nom. min. nom. min. nom. min.<br />

2<br />

3,7<br />

5,9<br />

7,4<br />

8,3<br />

10,4<br />

14,9<br />

19,0<br />

21,4<br />

24,0<br />

25,6<br />

27,5<br />

31,0<br />

34,2<br />

42,7<br />

50,1<br />

2<br />

3,7<br />

5,9<br />

7,4<br />

8,3<br />

10,4<br />

14,9<br />

19,0<br />

21,3<br />

23,8<br />

25,3<br />

27,0<br />

30,1<br />

33,0<br />

42,6<br />

49,2<br />

55,5<br />

UC 1200 SS 22 4P FRNC: TRANSMISSION CHARACTERUSTICS ACC. TO CATEGORY 7 (at 20 °C)<br />

Fre quency<br />

MHz<br />

1<br />

4<br />

10<br />

16<br />

20<br />

31,2<br />

62,5<br />

100<br />

125<br />

155,5<br />

175<br />

200<br />

250<br />

300<br />

450<br />

600<br />

1200<br />

Attenuation<br />

(dB/100 m)<br />

80<br />

80<br />

80<br />

80<br />

80<br />

80<br />

75<br />

72<br />

71<br />

70<br />

69<br />

68<br />

66<br />

65<br />

63<br />

61<br />

NEXT<br />

(dB)<br />

90<br />

90<br />

90<br />

90<br />

90<br />

90<br />

90<br />

87<br />

85<br />

84<br />

83<br />

82<br />

81<br />

80<br />

77<br />

75<br />

73<br />

80<br />

80<br />

80<br />

80<br />

80<br />

75<br />

71<br />

68<br />

66<br />

65<br />

64<br />

63<br />

62<br />

60<br />

58<br />

56<br />

87<br />

87<br />

87<br />

87<br />

87<br />

87<br />

87<br />

84<br />

82<br />

81<br />

80<br />

79<br />

78<br />

77<br />

74<br />

72<br />

70<br />

PS-NEXT<br />

(dB)<br />

78,0<br />

76,3<br />

74,1<br />

72,6<br />

71,7<br />

69,6<br />

60,1<br />

53,0<br />

49,6<br />

46,0<br />

43,4<br />

40,5<br />

35,0<br />

30,8<br />

20,3<br />

10,9<br />

ACR<br />

88,0<br />

86,3<br />

84,1<br />

82,6<br />

81,7<br />

79,6<br />

74,8<br />

67,7<br />

63,9<br />

60,0<br />

57,8<br />

55,2<br />

50,6<br />

46,5<br />

34,3<br />

25,8<br />

17,5<br />

(dB/100 m)<br />

78,0<br />

76,3<br />

74,1<br />

72,6<br />

71,7<br />

64,6<br />

56,1<br />

49,0<br />

44,6<br />

41,0<br />

38,4<br />

35,5<br />

31,0<br />

25,8<br />

15,3<br />

5,9<br />

PS-ACR<br />

85,0<br />

83,3<br />

81,1<br />

79,6<br />

78,7<br />

76,6<br />

71,8<br />

64,7<br />

60,9<br />

57,0<br />

54,8<br />

52,2<br />

47,6<br />

43,5<br />

31,3<br />

22,8<br />

14,5<br />

(dB/100 m)<br />

70<br />

58<br />

50<br />

46<br />

44<br />

40<br />

34<br />

30<br />

28<br />

26<br />

25<br />

24<br />

22<br />

20<br />

17<br />

14<br />

ELFEXT<br />

80<br />

80<br />

80<br />

76<br />

74<br />

70<br />

64<br />

60<br />

58<br />

56<br />

55<br />

54<br />

52<br />

50<br />

47<br />

44<br />

42<br />

(dB/100 m)<br />

67<br />

55<br />

47<br />

43<br />

41<br />

37<br />

31<br />

27<br />

25<br />

23<br />

22<br />

21<br />

19<br />

17<br />

14<br />

11<br />

77<br />

77<br />

77<br />

73<br />

71<br />

67<br />

61<br />

57<br />

55<br />

53<br />

52<br />

51<br />

49<br />

47<br />

44<br />

41<br />

39<br />

PS-ELFEXT<br />

(dB/100 m)<br />

max. nom. min. nom. min. nom. min. nom. min. nom. min. nom. min. nom. min.<br />

2<br />

3,7<br />

5,9<br />

7,4<br />

8,3<br />

10,4<br />

14,9<br />

19,0<br />

21,4<br />

24,0<br />

25,6<br />

27,5<br />

31,0<br />

34,2<br />

42,7<br />

50,1<br />

1,7<br />

3,1<br />

5,2<br />

6,5<br />

7,0<br />

9,0<br />

13,0<br />

16,5<br />

19,0<br />

21,5<br />

22,5<br />

24,1<br />

26,9<br />

28,5<br />

34,9<br />

43,5<br />

58,0<br />

80<br />

80<br />

80<br />

80<br />

80<br />

80<br />

75<br />

72<br />

71<br />

70<br />

69<br />

68<br />

66<br />

65<br />

63<br />

61<br />

100<br />

100<br />

100<br />

100<br />

100<br />

100<br />

100<br />

100<br />

99<br />

97<br />

96<br />

95<br />

94<br />

93<br />

90<br />

88<br />

85<br />

77<br />

77<br />

77<br />

77<br />

77<br />

77<br />

72<br />

69<br />

68<br />

67<br />

66<br />

65<br />

63<br />

62<br />

60<br />

58<br />

97<br />

97<br />

97<br />

97<br />

97<br />

97<br />

97<br />

97<br />

96<br />

94<br />

93<br />

92<br />

91<br />

90<br />

87<br />

85<br />

82<br />

78,0<br />

76,3<br />

74,1<br />

72,6<br />

71,7<br />

69,6<br />

60,1<br />

53,0<br />

49,6<br />

46,0<br />

43,4<br />

40,5<br />

35,0<br />

30,8<br />

20,3<br />

10,9<br />

98,3<br />

96,9<br />

94,8<br />

93,5<br />

93,0<br />

91,0<br />

87,0<br />

83,5<br />

79,5<br />

75,6<br />

73,9<br />

71,4<br />

67,1<br />

64,3<br />

55,3<br />

44,8<br />

27,0<br />

75,0<br />

73,3<br />

71,1<br />

69,6<br />

68,7<br />

66,6<br />

57,1<br />

50,0<br />

46,6<br />

43,0<br />

40,4<br />

37,5<br />

32,0<br />

27,8<br />

17,3<br />

7,9<br />

95,3<br />

93,9<br />

91,8<br />

90,5<br />

90,0<br />

88,0<br />

84,0<br />

80,5<br />

76,5<br />

72,6<br />

70,9<br />

68,4<br />

64,1<br />

61,3<br />

52,3<br />

41,8<br />

24,0<br />

70<br />

58<br />

50<br />

46<br />

44<br />

40<br />

34<br />

30<br />

28<br />

26<br />

25<br />

24<br />

22<br />

20<br />

17<br />

14<br />

98<br />

97<br />

95<br />

94<br />

93<br />

91<br />

87<br />

84<br />

81<br />

79<br />

78<br />

76<br />

73<br />

72<br />

65<br />

57<br />

42<br />

67<br />

55<br />

47<br />

43<br />

41<br />

37<br />

31<br />

27<br />

25<br />

23<br />

22<br />

21<br />

19<br />

17<br />

14<br />

11<br />

95<br />

94<br />

92<br />

91<br />

90<br />

88<br />

84<br />

81<br />

78<br />

76<br />

75<br />

73<br />

70<br />

69<br />

62<br />

54<br />

39<br />

Return<br />

loss<br />

(dB)<br />

23<br />

23<br />

23<br />

23<br />

23<br />

23<br />

23<br />

23<br />

21<br />

21<br />

21<br />

21<br />

19<br />

19<br />

19<br />

19<br />

Return<br />

loss<br />

(dB)<br />

23<br />

23<br />

23<br />

23<br />

23<br />

23<br />

23<br />

23<br />

21<br />

21<br />

21<br />

21<br />

19<br />

19<br />

19<br />

19<br />

77


DATA CA BLES<br />

78<br />

AP PLI CA TIONS<br />

Aerial, duct or direct buried installations<br />

— Fixed outdoor — Eth er net 1000 Mbit/s, 100 Mbit/s<br />

in stal la tions — Tele phone net works<br />

— CDDI — ISDN<br />

— TP- PMD — Ge neric ca bling sys tem<br />

— ATM<br />

Maxi mum ambient tem pera ture:<br />

- in operation +75 °C<br />

Low est rec om mended installation<br />

tem pera ture: –70 °C<br />

Mini mum rec om mended bend ing ra dius:<br />

- without load ≥ 35 mm<br />

- with load ≥ 70 mm<br />

Category 5 outdoor cable, UTP/armoured UTP<br />

SuperCAT<br />

STAN DARDS<br />

EIA/TIA 568A<br />

ISO/IEC 11801 2 nd edition; JTC1 SC25 WG3 N552<br />

EN 50173<br />

IDEN TI FI CA TION<br />

Pair Col our code Pair Col our code<br />

1 white/blue 3 white/green<br />

2 white/orange 4 white/brown<br />

The right to al tera tions re served.


CON STRUC TION<br />

Con duc tor Bare cop per wire, d = 0,50 mm<br />

In su la tion PE<br />

Twisting 2 cores to the pair<br />

Cable lay up 4 pairs to the core<br />

CA BLE SIZES<br />

Category 5 outdoor cable, UTP/armoured UTP<br />

SuperCAT<br />

Filling Specially jelly<br />

compound<br />

Sheath Black PVC<br />

Fylly flooded - waterproof<br />

Tough UV <strong>and</strong> abrasion resistant jacket<br />

DATA CA BLES<br />

Armoured UTP:<br />

Optional aluminium or steel shielding system<br />

Type Supercat 5 UTP Supercat 5 armoured UTP<br />

EAN code (SSTL code) 64 100+ 02 601 00 02 601 01<br />

Nomi nal di ame ters mm 5,8 8,6<br />

Mass kg/km 50 130<br />

De liv ery length m 305 305<br />

ELEC TRI CAL PROP ER TIES 20 °C<br />

Loop re sis tance, max Ω/km ≤188<br />

Re sis tance, min Ω x 100 m ≤9,38<br />

Resistance unbalance % ≤3<br />

Ca paci tance at 800 Hz pF/m 55,8<br />

Insulation resistance<br />

(500 V) MΩ x km ≥ 2000<br />

Max propagation delay skew ns/100 m ≤ 45<br />

Ve loc ity of propagation % 69<br />

TRANSMISSION CHARACTERUSTICS ACC. TO CATEGORY 5e (at 20 °C)<br />

Fre quency<br />

MHz<br />

1<br />

4<br />

10<br />

16<br />

20<br />

31,2<br />

62,5<br />

100<br />

Attenuation<br />

(dB/100 m)<br />

NEXT<br />

(dB)<br />

PS-NEXT<br />

(dB)<br />

ACR<br />

(dB/100 m)<br />

PS-ACR<br />

(dB/100 m)<br />

ELFEXT<br />

(dB/100 m)<br />

PS-ELFEXT<br />

(dB/100 m)<br />

max. nom. min. nom. min. nom. min. nom. min. nom. min. nom. min. nom. min.<br />

2,0<br />

4,1<br />

6,5<br />

8,2<br />

9,3<br />

11,7<br />

17,0<br />

22,0<br />

1,9<br />

3,9<br />

6,2<br />

7,9<br />

9,0<br />

11,3<br />

16,4<br />

21,2<br />

85,0<br />

79,2<br />

59<br />

56<br />

55<br />

52<br />

47<br />

44<br />

65,0<br />

56,3<br />

63<br />

60<br />

59<br />

56<br />

51<br />

48<br />

79<br />

73<br />

62,7<br />

61,1<br />

61,1<br />

53,2<br />

52,6<br />

44,8<br />

62<br />

53,3<br />

47,3<br />

44,3<br />

42,8<br />

39,9<br />

35,4<br />

32,3<br />

83,1<br />

75,3<br />

62,2<br />

58,6<br />

58,3<br />

50,4<br />

42,4<br />

30,5<br />

63,3<br />

52,2<br />

43,8<br />

39,1<br />

36,5<br />

30,2<br />

21,4<br />

13,3<br />

77,1<br />

69,2<br />

56,5<br />

53,2<br />

52,0<br />

41,8<br />

36,2<br />

23,6<br />

60,3<br />

49,2<br />

40,8<br />

39,1<br />

33,5<br />

28,2<br />

18,4<br />

10,3<br />

84,9<br />

74,3<br />

66,5<br />

62,5<br />

61,6<br />

57,0<br />

50,6<br />

44,9<br />

63,8<br />

51,7<br />

43,8<br />

39,7<br />

37,7<br />

33,8<br />

27,8<br />

23,8<br />

78,8<br />

67,8<br />

60,0<br />

55,8<br />

53,7<br />

49,7<br />

43,6<br />

39,1<br />

60,8<br />

48,7<br />

40,8<br />

36,7<br />

34,7<br />

30,8<br />

24,8<br />

20,8<br />

Return<br />

loss<br />

(dB)<br />

20,0<br />

23<br />

25,5<br />

25,0<br />

25,0<br />

23,6<br />

21,5<br />

20,1<br />

The right to al tera tions re served.<br />

79


80<br />

Fibre optic cables in premises<br />

data networks


TYPE COD ING OF OP TI CAL FI BRE<br />

CA BLES<br />

An ex am ple of the ca ble des ig na tion<br />

Cable construction<br />

Number <strong>and</strong> grouping of the fibres<br />

Type of the fibre <strong>and</strong> the coating<br />

Characteristics of the fibres<br />

Ca ble con struc tion<br />

First let ter:<br />

F = op ti cal fi bre ca ble<br />

FYOVD2PMU 4 x 6 x SML 04S03T<br />

Sec ond let ter:<br />

Y = sin gle loose tube con struc tion (SPI RAL SPACE ® )<br />

Z = str<strong>and</strong>ed loose tube con struc tion<br />

T = str<strong>and</strong>ed tight buffer con struc tion<br />

X = slot ted core con struc tion<br />

Next let ters:<br />

B = laminated O = filling compound<br />

C = copper P = round steel wire<br />

D = corrugated R = nonmetallic<br />

H = metal (aluminium) strength member<br />

tape V = steel tape<br />

J = jute S = indoor installation<br />

K = messenger U = outdoor installation<br />

wire<br />

L = lead<br />

M = plastic W = submarine<br />

-Y = combination cable (the last letter)<br />

Ex am ple: FYOVD2PMU (op ti cal fi bre ca ble,<br />

SPI RAL SPACE ® de sign, jelly filled, cor ru gated steel tape,<br />

plas tic sheath with two steel wires, <strong>for</strong> out door in stal la tion)<br />

Num ber <strong>and</strong> group ing of the fi bres<br />

The num bers fol low ing the let ter code in di cate the number<br />

of the fi bre groups (i.e. tubes or bun dles) <strong>and</strong> the number<br />

of the fi bres in each group.<br />

Ex am ple: 4x6 (four groups of six fi bres)<br />

Type of the fi bre <strong>and</strong> its coat ing<br />

The first two let ters of the code in di cate the type of the<br />

fi bre:<br />

SM = Single- mode fi bre (10/125 µm) ITU-T G.652<br />

GI = Mul ti mode fi bre (50/125 µm) ITU-T G.651<br />

GK = Mul ti mode fi bre (62.5/125 µm)<br />

GL = Mul ti mode fi bre (85/125 µm)<br />

GN = Mul ti mode fi bre (100/140 µm)<br />

The third let ter in di cates the outer di ame ter or the type of<br />

the coat ing<br />

L = 250 µm T = 900 µm<br />

W = 500 µm R = Rib bon<br />

Ex am ple: MSL<br />

(Single- mode fi bre ITU-T G.652 with 250 µm coat ing)<br />

GENERAL<br />

Char ac ter is tics of the fi bres<br />

The at tenua tion of the fi bre is given in tenths of deci bels<br />

per kilo me tre with two num bers fol lowed by the let ter<br />

in di cat ing the cor re spond ing wave length:<br />

F =850 nm, S =1300 nm, T = 550 nm<br />

Ex am ple: 04S03T<br />

(0.4 dB/km at 1300 nm: 0.3 dB/km at 1550 nm)<br />

For mul ti mode fi bres also the b<strong>and</strong> width is given in<br />

hun dreds of MHz km with two fig ures fol low ing the<br />

at tenua tion value.<br />

Ex am ple: 1008S (1.0 dB/km, 800 Mhz km at 300 nm)<br />

COL OUR COD ING SYS TEM OF<br />

OP TI CAL FI BRE CA BLES<br />

A col our cod ing sys tem is used <strong>for</strong> iden ti fi ca tion of op ti cal<br />

fi bres, fi bre groups <strong>and</strong> tubes. A fi bre group has nor mally<br />

not more than 6 fi bres, which are col oured as fol lows:<br />

— blue (al ways the first one)<br />

— white<br />

— yel low<br />

— green<br />

— grey<br />

— red (al ways the last one)<br />

The same col our cod ing sys tem is adapted to the bind ers<br />

over the fi bre bun dles.<br />

OPTICAL FIBRE TYPES<br />

Core Cladding<br />

Primary coating<br />

The construction <strong>and</strong> the operation principle of a single-mode<br />

fibre<br />

Core Cladding<br />

Primary coating<br />

The construction <strong>and</strong> the operation principle of a multimode<br />

fibre<br />

81


82<br />

DIFFERENT CONSTRUCTIONS OF OPTICAL FIBRE CABLES<br />

Single loose-tube<br />

FY...<br />

SPIRAL SPACE ®<br />

OPTICAL FIBRE CABLES OF NK CABLES FOR DIFFERENT APPLICATIONS<br />

Duct <strong>and</strong> buried cables<br />

SPIRAL SPACE®<br />

FYOVD2PMU steel tape armoured Spiral Space®<br />

FYO2RMU non-metallic Spiral Space® cable<br />

FZOMU non-metallic str<strong>and</strong>ed loose tube cable<br />

SPIRAL SPACE ®<br />

Buried <strong>and</strong> duct cable FYOHB2PMU<br />

Buried <strong>and</strong> duct cable FZOMVDMU<br />

CONTENTS<br />

Str<strong>and</strong>ed loose-tube<br />

FZ...<br />

Indoor cables<br />

FMS non-metallic jumper cables<br />

FMMS non-metallic breakout cable<br />

FYMSU non-metallic Spiral Space® cable<br />

Indoor installation cable FLMS<br />

Indoor cable FMMS<br />

Slotted core<br />

FX...<br />

SPIRAL SPACE ®<br />

SPIRAL SPACE ®<br />

Non-metallic buried <strong>and</strong> duct cable<br />

FYO2RMU


FYMSU-TERM DISTRIBUTION PANELS AND<br />

CABINETS<br />

CONNECTORISED RISER CABLES<br />

FYMSU-PACK 100<br />

Pigtails<br />

CONTENTS<br />

PK-100A <strong>and</strong> PK-200<br />

ORP-250<br />

PK 300<br />

83


DATA CA BLES<br />

84<br />

AP PLI CA TIONS<br />

— Fixed in door — To ken Ring 4/16 Mbit/s<br />

in stal la tions — Tele phone net works<br />

— Eth er net 10 Mbit/s — RS 232/422/423<br />

Maxi mum ambient tem pera ture:<br />

- in operation +70 °C<br />

Low est rec om mended installation<br />

tem pera ture: –5 °C<br />

Mini mum rec om mended bend ing ra dius:<br />

- dur ing in stal la tion 10xD<br />

- during operation 15xD<br />

Data <strong>and</strong> instru men ta ti on cab le<br />

DA TA JA MAK<br />

DA TA JA MAK is available as halo gen free, DATAJAMAK- HF ver sion.<br />

STAN DARDS<br />

ISO 8802.3/IEEE 802.3 10 base T<br />

IDEN TI FI CA TION<br />

a- conductor is white <strong>and</strong> b- conductor is or ange<br />

The ca ble fufils the fire con di tion re quire ments of<br />

IEC 332-1.


CON STRUC TION<br />

Con duc tor Str<strong>and</strong>ed tinned cop per<br />

In su la tion PE<br />

Unit Twisted <strong>and</strong> in di vidu ally shielded pair<br />

with plas tic-alu min ium tape, earth<br />

con duc tor <strong>and</strong> a number tape<br />

CA BLE SIZES<br />

Data <strong>and</strong> instru men ta ti on cab le<br />

DA TA JA MAK<br />

Shield Plas tic-alu min ium tape with earth<br />

con duc tor<br />

Sheath Grey LINYL- PVC<br />

Num ber <strong>and</strong> size of<br />

the con duc tors mm 2 2 x (2+1) x 0,24 4 x (2+1) x 0,24 8 x (2+1) x 0,24<br />

EAN code (STTL code) 64 100+ 02 642 53-7 02 642 55-1 02 642 60-5<br />

Nomi nal di ame tersr mm 7,5 9,0 12<br />

Mass kg/km 50 75 140<br />

De liv ery length m 1000 1000 1000<br />

ELEC TRI CAL PROP ER TIES 20 °C<br />

Loop re sis tance, max Ω/km 165<br />

Nomi nal mutual ca paci tance pF/m 52<br />

Capacitance earth unbalance<br />

pair to ground 1 Khz, max pF/km<br />

Nominal impedance Ω 100±15<br />

Insulatio resistance, min GΩ x km 2<br />

Ve loc ity fac tor 0,7<br />

Maximum voltage V 75<br />

Frequency 9,6 kHz<br />

fre quency 9,2 kHz<br />

fre quency 64 kHz<br />

fre quency 100 kHz<br />

fre quency 200 kHz<br />

fre quency 1,0 MHz<br />

fre quency 4,0 MHz<br />

fre quency 10 MHz<br />

fre quency 16 Mhz<br />

Frequency 9,6 kHz<br />

fre quency 9,2 kHz<br />

fre quency 64 kHz<br />

fre quency 100 kHz<br />

fre quency 200 kHz<br />

fre quency 1,0 MHz<br />

fre quency 4,0 MHz<br />

fre quency 10 MHz<br />

fre quency 16 Mhz<br />

DA TA JA MAK is available as halo gen free, DATAJAMAK- HF ver sion.<br />

1500<br />

Max at tenua tion dB/100 m<br />

0,3<br />

0,5<br />

0,7<br />

0,9<br />

1,5<br />

3,3<br />

6,6<br />

9,5<br />

11,5<br />

NEXT min dB<br />

90<br />

90<br />

85<br />

85<br />

80<br />

80<br />

70<br />

70<br />

70<br />

DATA CA BLES<br />

The right to al tera tions re served.<br />

85


DATA CA BLES<br />

86<br />

AP PLI CA TIONS<br />

Wiring of digital exchanges <strong>and</strong> PCM equipment.<br />

CON STRUC TION<br />

KLVMAAM<br />

Installation cables <strong>for</strong> exchanges with screened pairs<br />

KLVMAAM, KLVMAM<br />

Con duc tor Annealed, tinned cop per wire<br />

In su la tion Cellular PE<br />

Group Two insulated conductors in a pair<br />

Group screen Plastic aluminium foil <strong>and</strong> ground wire<br />

Collective Two layers of plastic aluminium foil <strong>and</strong><br />

screen ground wire<br />

Sheath Grey Linyl<br />

CA BLE SIZES<br />

Num ber <strong>and</strong> size of<br />

the con duc tors mm 2<br />

IDEN TI FI CA TION<br />

a- conductor is white <strong>and</strong> b- conductor is blue<br />

Screened groups numbered<br />

KLVMAAM KLVMAM<br />

2 x (2+1) x 0,4 8 x (2+1) x 0,4 16 x (2+1) x 0,4 24 x (2+1) x 0,4 2 x 0,4 x 0,4<br />

EAN code (STTL code) 64 100+ 02 021 52-3 02 021 58-5 02 021 61-5 02 021 64-6 02 021 02-8<br />

Nomi nal seath thickness mm 0,6 0,6 1,2 1,2 0,6<br />

Nominal outer diameter mm 4 x 6,5 9,0 12,5 15,0 3,5<br />

Nominal cable mass kg/km 30 75 160 220 14<br />

St<strong>and</strong>ard de liv ery length m 1000/200 1000/100 500/100 500 1000<br />

ELEC TRI CAL PROP ER TIES 20 °C<br />

KLVMAM<br />

Characteristic impedance 1 MHz Ω 120<br />

Nomi nal mu tual ca paci tance<br />

800 MHz nF/km 47<br />

Minimum in su la tion re sis tance<br />

500 V, 1 min GΩ x km 2<br />

Attenuation<br />

1 MHz dB/100 m 3,7<br />

Minimum near-end crosstalk<br />

attenuation 1 MHz dB/100 m 80<br />

Con duc tor Annealed, tinned cop per wire<br />

In su la tion Cellular PE<br />

Group Two insulated conductors in a pair<br />

Screen Plastic aluminium foil <strong>and</strong> ground wire<br />

Sheath Black Linyl<br />

The right to al tera tions re served.


AP PLI CA TIONS<br />

Indoor cable <strong>for</strong> CATV systems<br />

Low est rec om mended installation<br />

tem pera ture: –5 °C<br />

CON STRUC TION<br />

Inner conductor Annealed copper wire<br />

Insulation Foamed PE<br />

CA BLE SIZES<br />

Num ber <strong>and</strong> size of<br />

the con duc tors mm 2<br />

Indoor cable <strong>for</strong> community antenna system<br />

TELLU 13<br />

TELLU 13 WHITE drum TELLU 13 WHITE coil<br />

EAN code (STTL code) 64 100+ 02 821 86-4 02 321 86-9<br />

Nomi nal di ame ter of<br />

the inner conductor mm 1,0 1,0<br />

Nomi nal di ame ter of<br />

the insulated conductor mm 4,8 4,8<br />

Nominal outer diameter mm 7,0 7,0<br />

Mass kg/km 56 56<br />

De liv ery length m 1000 200<br />

ELEC TRI CAL PROP ER TIES 20 °C<br />

Nominal loop DC-re sis tance Ω/km 34<br />

Nomi nal ca paci tance pF/m 56<br />

Characteristic im ped ance Ω 75 ±2<br />

Ve loc ity fac tor 80<br />

Structural return loss, min. dB<br />

30 - 470 MHz<br />

470 - 860 Mhz<br />

860 - 1750 MHz<br />

Screening attenuation, min. dB 80<br />

Max at tenua tion dB/100 m<br />

fre quency 68 MHz<br />

fre quency 108 MHz<br />

fre quency 174 MHz<br />

fre quency 230 MHz<br />

fre quency 300 MHz<br />

fre quency 400 MHz<br />

fre quency 470 MHz<br />

fre quency 606 MHz<br />

fre quency 790 MHz<br />

fre quency 860 MHz<br />

fre quency 1750 MHz<br />

fre quency 2050 MHz<br />

N<br />

Mini mum rec om mended single bend ing<br />

ra dius 15 mm<br />

Maxi mum per mis si ble ten sile stress<br />

dur ing in stal la tion 120 N<br />

SFS 5711<br />

Outer conductor Copper tape covered with<br />

a copper braid<br />

Sheath White Linyl<br />

18<br />

16<br />

14<br />

5,1<br />

6,5<br />

8,4<br />

9,7<br />

11,3<br />

13,2<br />

14,5<br />

16,7<br />

19,5<br />

20,5<br />

31,2<br />

34,4<br />

FORMULA FOR THE<br />

ATTENUATION COEFFICIENT OF<br />

TELLU INDOOR CABLE f ≥10 MHz<br />

α = A 1 f f + A 2f, where<br />

α = attenuation coefficient, dB/100 m<br />

f = frequency, MHz<br />

A 1 <strong>and</strong> A 2 are constants<br />

DATA CA BLES<br />

87


DATA CA BLES<br />

88<br />

AP PLI CA TIONS<br />

Indoor cable <strong>for</strong> CATV systems<br />

CA BLE SIZES<br />

Military cable<br />

RG 58, (50 Ω), RG 59, (75 Ω)<br />

Low est rec om mended installation<br />

tem pera ture: -5 °C<br />

CON STRUC TION<br />

Inner conductor<br />

RG 58r Str<strong>and</strong>ed copper wire, tin plated<br />

RG 59 Copperclad steel wire<br />

Insulation PE<br />

Type RG 58 C/U RG 59 B/U<br />

Nomi nal di ame ter of<br />

the inner conductor mm 0,9 0,59<br />

Nominal outer diameter mm 5,0 6,2<br />

Mass kg/km 40 57<br />

De liv ery length m 1000 1000<br />

ELEC TRI CAL PROP ER TIES 20 °C<br />

Nominal loop DC-re sis tance Ω/km 50 165<br />

Mutual ca paci tance pF/m 100 67<br />

Characteristic im ped ance Ω 50 ±2 75 ±3<br />

Ve loc ity ratio % 66 66<br />

Max at tenua tion dB/100 m<br />

fre quency 5 MHz<br />

fre quency 10 MHz<br />

fre quency 200 MHz<br />

fre quency 400 MHz<br />

fre quency 1000 MHz<br />

Transfer impedance at 3 MHz<br />

specified value mΩ/m<br />

measurement value mΩ/m<br />

operating voltage kV eff<br />

3,0<br />

4,2<br />

23<br />

34,5<br />

60<br />

50<br />

36<br />

1,8<br />

N<br />

Maxi mum per mis si ble ten sile stress<br />

dur ing in stal la tion RG 58: 120 N<br />

RG 59: 145 N<br />

Copper braid<br />

RG 58r Tin plated<br />

RG 59 Bare<br />

Sheath Black PVC<br />

2,5<br />

3,5<br />

16<br />

24<br />

38<br />

36<br />

2,0


Military cable<br />

RG 213, RG 214, RG 223, (50 Ω)<br />

AP PLI CA TIONS<br />

Indoor cable <strong>for</strong> CATV systems<br />

Low est rec om mended installation<br />

tem pera ture: -5 °C<br />

CON STRUC TION<br />

Inner conductor<br />

RG 213 Str<strong>and</strong>ed copper wire,<br />

bare 7x0,75<br />

RG 214 Str<strong>and</strong>ed copper wire,<br />

silver plated 7x0,75<br />

RG 223 Copper wire, silver plated<br />

Insulation PE<br />

CA BLE SIZES<br />

Maxi mum per mis si ble ten sile stress<br />

dur ing in stal la tion RG 213 470 N<br />

RG 214 730 N<br />

RG 223 220 N<br />

RG 213 bare<br />

RG 214, RG 223<br />

1st braid Silver plated<br />

2nd braid Silver plated<br />

Sheath PVC<br />

Type RG 213 RG 214 RG 223<br />

Nomi nal di ame ter of<br />

the inner conductor mm 2,25 2,25 0,9<br />

Nominal outer diameter mm 10,3 10,8 5,5<br />

Mass kg/km 157 226 60<br />

De liv ery length m 1000 1000 1000<br />

ELEC TRI CAL PROP ER TIES 20 °C<br />

DC-re sis tance Ω/km<br />

inner conductor<br />

1st braid<br />

2nd braid<br />

5,7<br />

3,9<br />

Mutual ca paci tance pF/m 100 100 100<br />

Characteristic im ped ance Ω 50 ±2 50 ±2 50 ±2<br />

Ve loc ity ratio % 0,66 0,66 0,66<br />

Max at tenua tion dB/100 m<br />

fre quency 60 MHz<br />

fre quency 80 MHz<br />

fre quency 200 MHz<br />

fre quency 400 MHz<br />

fre quency 1000 MHz<br />

Transfer impedance at 3 MHz<br />

operating voltage kV eff<br />

test voltage kV eff<br />

5<br />

6<br />

10<br />

15<br />

4,5<br />

10,0<br />

N<br />

5,7<br />

9,4<br />

8,2<br />

6,0<br />

7,5<br />

11<br />

17<br />

4,5<br />

10,0<br />

DATA CA BLES<br />

29,1<br />

13,5<br />

15,5<br />

18,2<br />

15,5<br />

21<br />

31<br />

1,9<br />

4,1<br />

89


90<br />

Diameter of cable<br />

Type of drum<br />

5C 6C 7E 8E 9F 11G 13G 15G 16L 18M 20P 22P<br />

3<br />

4<br />

4500<br />

2460<br />

7850<br />

4410 7250 9790<br />

5<br />

6<br />

1570<br />

1120<br />

2790<br />

1950<br />

4710<br />

3210<br />

6220<br />

4400<br />

9000<br />

6130<br />

7<br />

8<br />

780<br />

580<br />

1410<br />

1080<br />

2360<br />

1800<br />

3190<br />

2370<br />

4560<br />

3480 5720 7950<br />

9<br />

10<br />

480<br />

390<br />

840<br />

660<br />

1460<br />

1170<br />

1950<br />

1490<br />

2770<br />

2170<br />

4420<br />

3720<br />

6280<br />

5090 6930 9360<br />

11<br />

12<br />

320<br />

260<br />

570<br />

480<br />

930<br />

800<br />

1300<br />

1050<br />

1790<br />

1470<br />

2960<br />

2500<br />

4210<br />

3530<br />

5520<br />

4785<br />

7820<br />

6490<br />

8260<br />

7020<br />

13<br />

14<br />

200<br />

190<br />

410<br />

350<br />

680<br />

580<br />

910<br />

790<br />

1290<br />

1130<br />

2200<br />

1800<br />

3020<br />

2590<br />

3950<br />

3465<br />

5610<br />

4830<br />

5950<br />

5030 8420<br />

15<br />

16<br />

150<br />

140<br />

290<br />

240<br />

500<br />

420<br />

680<br />

590<br />

990<br />

870<br />

1620<br />

1410<br />

2260<br />

1990<br />

3040<br />

2565<br />

4150<br />

3750<br />

4480<br />

4000<br />

7310<br />

6320<br />

8900<br />

7780<br />

17<br />

18<br />

110<br />

100<br />

230<br />

190<br />

400<br />

340<br />

500<br />

480<br />

750<br />

650<br />

1250<br />

1100<br />

1750<br />

1570<br />

2310<br />

2070<br />

3190<br />

2870<br />

3300<br />

2960<br />

5740<br />

4930<br />

6770<br />

6170<br />

19<br />

20<br />

100 180<br />

150<br />

320<br />

270<br />

410<br />

340<br />

560<br />

540<br />

960<br />

930<br />

1410<br />

1270<br />

1840<br />

1685<br />

2590<br />

2330<br />

2830<br />

2510<br />

4460<br />

4040<br />

5630<br />

4860<br />

21<br />

22<br />

140<br />

140<br />

260<br />

210<br />

330<br />

320<br />

460<br />

440<br />

800<br />

710<br />

1150<br />

1050<br />

1480<br />

1420<br />

2080<br />

1860<br />

2220<br />

1960<br />

3650<br />

3290<br />

4410<br />

4010<br />

23<br />

24<br />

200 210<br />

160<br />

270<br />

260<br />

370<br />

360<br />

680<br />

590<br />

960<br />

880<br />

1290<br />

1155<br />

1800<br />

1610<br />

1890<br />

1670<br />

2960<br />

2870<br />

3630<br />

3520<br />

25<br />

26<br />

160<br />

150<br />

210<br />

210<br />

350<br />

290<br />

570<br />

540<br />

810<br />

750<br />

1110<br />

990<br />

1430<br />

1390<br />

1600<br />

1400<br />

2580<br />

2310<br />

3190<br />

2880<br />

27<br />

28<br />

150<br />

110<br />

200<br />

160<br />

290<br />

230<br />

470<br />

450<br />

690<br />

650<br />

940<br />

830<br />

1230<br />

1200<br />

1360<br />

1180<br />

2240<br />

2000<br />

2600<br />

2520<br />

29<br />

30<br />

110<br />

110<br />

160<br />

150<br />

230<br />

220<br />

430<br />

380<br />

600<br />

560<br />

790<br />

725<br />

1050<br />

1030<br />

1140<br />

1110<br />

1950<br />

1730<br />

2260<br />

2210<br />

31<br />

32<br />

110<br />

100<br />

150<br />

150<br />

220<br />

170<br />

360<br />

345<br />

530<br />

500<br />

690<br />

630<br />

890<br />

870<br />

950<br />

930<br />

1690<br />

1490<br />

1970<br />

1930<br />

33<br />

34<br />

110<br />

110<br />

170<br />

170<br />

300<br />

315<br />

470<br />

440<br />

595<br />

560<br />

860<br />

740<br />

900<br />

770<br />

1450<br />

1420<br />

1720<br />

1680<br />

35<br />

36<br />

110<br />

100<br />

160<br />

160<br />

305<br />

280<br />

410<br />

390<br />

555<br />

480<br />

720<br />

710<br />

750<br />

730<br />

1250<br />

1220<br />

1640<br />

1450<br />

37<br />

38<br />

100 120<br />

120<br />

270<br />

240<br />

370<br />

350<br />

470<br />

445<br />

610<br />

610<br />

720<br />

600<br />

1190<br />

1040<br />

1420<br />

1390<br />

39<br />

40<br />

120<br />

120<br />

230<br />

225<br />

330<br />

320<br />

420<br />

410<br />

580<br />

570<br />

580<br />

570<br />

1020<br />

1000<br />

1220<br />

1200<br />

41<br />

42<br />

110<br />

110<br />

210<br />

200<br />

300<br />

280<br />

405<br />

385<br />

560<br />

480<br />

560<br />

550<br />

980<br />

840<br />

1180<br />

1030<br />

43<br />

44<br />

195<br />

175<br />

270<br />

260<br />

370<br />

355<br />

470<br />

460<br />

450<br />

440<br />

830<br />

810<br />

1010<br />

990<br />

45<br />

46<br />

170<br />

165<br />

250<br />

240<br />

320<br />

325<br />

450<br />

380<br />

430<br />

420<br />

800<br />

680<br />

970<br />

840<br />

47<br />

48<br />

160<br />

150<br />

230<br />

220<br />

310<br />

290<br />

370<br />

360<br />

420<br />

410<br />

670<br />

660<br />

820<br />

810<br />

49<br />

50<br />

145<br />

140<br />

210<br />

200<br />

280<br />

275<br />

360<br />

350<br />

400<br />

320<br />

650<br />

640<br />

800<br />

790<br />

51<br />

52<br />

135 190<br />

180<br />

270<br />

250<br />

350<br />

280<br />

310<br />

310<br />

630<br />

520<br />

670<br />

660<br />

53<br />

54<br />

180<br />

170<br />

240<br />

230<br />

280<br />

270<br />

300<br />

300<br />

510<br />

510<br />

650<br />

640<br />

55<br />

56<br />

170<br />

160<br />

220<br />

210<br />

270<br />

270<br />

300<br />

290<br />

500<br />

490<br />

630<br />

620<br />

57<br />

58<br />

150<br />

150<br />

210<br />

200<br />

260<br />

260<br />

290<br />

280<br />

490<br />

400<br />

520<br />

510<br />

59<br />

60<br />

140<br />

140<br />

195<br />

190<br />

260<br />

200<br />

210<br />

210<br />

390<br />

390<br />

510<br />

500<br />

MA XI MUM LENGTH OF CAB LE<br />

PER DRUM, IN ME TERS<br />

CA BLE DRUMS


Type of<br />

drum<br />

5C<br />

6A<br />

7E<br />

8E<br />

9F<br />

11G<br />

13G<br />

15G<br />

16L<br />

18M<br />

20P<br />

22P<br />

K6<br />

K7<br />

K8<br />

K9<br />

K11<br />

K12<br />

K14<br />

K16<br />

K18<br />

EAN code<br />

(STTL-code)<br />

64 100 +<br />

99 994 05-2<br />

99 994 06-9<br />

99 994 07-6<br />

99 994 08-3<br />

99 994 09-0<br />

99 994 59-5<br />

99 994 63-2<br />

99 994 65-6<br />

99 994 16-8<br />

99 994 18-2<br />

99 994 21-2<br />

99 994 22-9<br />

DI MEN SI ONS AND WEIGHTS<br />

Drum dimensions, mm Drum weight<br />

A B C D E<br />

500<br />

600<br />

700<br />

800<br />

900<br />

1100<br />

1300<br />

1500<br />

1600<br />

1800<br />

2000<br />

2200<br />

600<br />

700<br />

800<br />

900<br />

1100<br />

1200<br />

1400<br />

1600<br />

1800<br />

500<br />

500<br />

610<br />

610<br />

660<br />

725<br />

760<br />

760<br />

970<br />

1025<br />

1155<br />

1155<br />

468<br />

580<br />

580<br />

630<br />

762<br />

982<br />

982<br />

1018<br />

1075<br />

D<br />

B<br />

250<br />

250<br />

325<br />

375<br />

425<br />

500<br />

600<br />

700<br />

800<br />

1100<br />

1100<br />

1200<br />

250<br />

325<br />

375<br />

425<br />

575<br />

675<br />

800<br />

950<br />

1100<br />

E C<br />

A<br />

400<br />

400<br />

500<br />

500<br />

550<br />

600<br />

600<br />

600<br />

800<br />

850<br />

960<br />

960<br />

400<br />

500<br />

500<br />

550<br />

650<br />

850<br />

850<br />

850<br />

850<br />

55<br />

55<br />

55<br />

55<br />

82<br />

82<br />

82<br />

82<br />

82<br />

82<br />

82<br />

82<br />

75<br />

75<br />

75<br />

75<br />

106<br />

106<br />

106<br />

106<br />

106<br />

CA BLE DRUMS<br />

kg<br />

10<br />

16<br />

20<br />

26<br />

40<br />

70<br />

105<br />

150<br />

185<br />

260<br />

350<br />

445<br />

12<br />

20<br />

25<br />

34<br />

55<br />

90<br />

115<br />

195<br />

230<br />

91


<strong>Draka</strong> NK <strong>Cables</strong> Ltd • Kimmeltie 1, 02110 Espoo, P.O. BOX 419, FIN-00101 Helsinki, Finl<strong>and</strong><br />

Tel. +358 10 5661 • Telefax +358 9 682 1007<br />

www.drakankc.fi