Fibre optic cables - Draka
Fibre optic cables - Draka
Fibre optic cables - Draka
Transform your PDFs into Flipbooks and boost your revenue!
Leverage SEO-optimized Flipbooks, powerful backlinks, and multimedia content to professionally showcase your products and significantly increase your reach.
<strong>Fibre</strong> <strong>optic</strong> <strong>cables</strong><br />
<strong>Fibre</strong> <strong>optic</strong> <strong>cables</strong><br />
1
<strong>Draka</strong> Comteq Finland<br />
<strong>Draka</strong> designs, manufactures and supplies <strong>cables</strong><br />
and accessories and offer its products and related<br />
services to telecommunications, electricity transmission,<br />
construction and other industries. <strong>Draka</strong> is<br />
largest producer of <strong>optic</strong>al fibre <strong>cables</strong> and datacom<br />
<strong>cables</strong> in Europe and one of the leading producers of<br />
mobile network <strong>cables</strong> in the world. <strong>Draka</strong> is also the<br />
biggest multi mode fibre and second largest single<br />
mode fibre producer in the world.<br />
www.draka.fi<br />
The information expressed in this document must<br />
not be copied or reproduced in any other form - be<br />
it partially or in full, without prior written consent<br />
of <strong>Draka</strong> Comteq Finland Ltd. The information<br />
presented is believed to be correct at the time of<br />
going to print. <strong>Draka</strong> Comteq Finland Ltd reserves<br />
the right to alter technical information without<br />
prior notice. This information is not binding except<br />
where expressly declared by <strong>Draka</strong> Comteq<br />
Finland Ltd.<br />
Quality management system<br />
<strong>Draka</strong> Comteq Finland’s quality management system has<br />
been approved by an authorized certification company<br />
according to ISO 9001 standard. Operating according<br />
to the standard guarantees the quality and continuous<br />
improvement of our products and processes.<br />
Environmental system<br />
<strong>Draka</strong> Comteq Finland’s environmental management<br />
system has been created to offer our customers products<br />
of better quality with less environmental impacts. The<br />
environmental system is followed through, controlled and<br />
developed in all our operations and it has been approved<br />
by an authorized certification company according to<br />
ISO14001 environmental standard.<br />
2 <strong>Fibre</strong> <strong>Fibre</strong> <strong>optic</strong> <strong>optic</strong> <strong>cables</strong><br />
3
Contact information<br />
<strong>Draka</strong> Comteq Finland Ltd.<br />
P.O.Box 419<br />
FI-00101 Helsinki, Finland<br />
Tel. +358 10 5661<br />
Fax +358 10 566 3394<br />
E-mail: firstname.lastname@draka.com<br />
Marketing and Sales<br />
Martti Puoskari<br />
Director Sales and Marketing<br />
Managing Director<br />
Tel. +358 10 566 3600<br />
+358 40 758 7199<br />
Fax +358 9 870 2042<br />
Sales<br />
Sirkku Laine<br />
Sales Manager<br />
Tel. +358 10 566 3722<br />
+358 40 748 3447<br />
Fax +358 10 566 3668<br />
Customer Care<br />
Sirpa Iltanen<br />
Sales Assistant<br />
Tel. +358 10 566 3603<br />
+358 40 588 6937<br />
Fax +358 9 870 2238<br />
Technical Support<br />
Petri Utulahti<br />
Product Manager, Cables<br />
Tel. +358 10 566 3439<br />
+358 40 709 039<br />
Fax +358 9 870 2238<br />
Hannu Väätämöinen<br />
Product Group Manager<br />
FTTH Cabling Solutions<br />
Tel. +358 10 566 3298<br />
+358 40 587 6757<br />
Fax +358 10 566 3668<br />
4 <strong>Fibre</strong> <strong>Fibre</strong> <strong>optic</strong> <strong>optic</strong> <strong>cables</strong><br />
5
Generic cabling<br />
<strong>Draka</strong> Linkki is <strong>Draka</strong>’s premises cabling solution<br />
for a highly reliable open cabling system.<br />
<strong>Draka</strong>’s wide cable range covers products suitable<br />
for premises communication networks. As the<br />
generic cabling application standards have been<br />
revised, these <strong>cables</strong> and other related components<br />
have been integrated into the concept of<br />
<strong>Draka</strong> Linkki.<br />
<strong>Draka</strong> Linkki is an open cabling system that<br />
complies with the European standard on<br />
generic cabling. The cabling system is suitable for<br />
telephone networks including broadband access<br />
interfaces, local area networks and control and<br />
building automation applications. In terms of<br />
copper <strong>cables</strong>, we offer the UC (Universal Cable)<br />
series comprising generic <strong>cables</strong> in categories<br />
5, 6 and 7, and a Supercat cable for outdoor<br />
applications.<br />
For longer distances and connections between<br />
buildings, especially when fast connections are<br />
needed, we recommend the use of fibre <strong>optic</strong><br />
<strong>cables</strong>. The multimode fibre cable categories<br />
listed in the cabling standards are OM1, OM2<br />
and OM3. The corresponding categories for<br />
single-mode fibre <strong>cables</strong> are OS1 and OS2. We<br />
offer products in all these fibre classes.<br />
You can choose from our wide product range: the<br />
FZOMSU-SD, a generic premises cable suitable<br />
for indoor/outdoor use, and the FTMS for horizontal<br />
cabling. These <strong>cables</strong> can be supplied with<br />
different category fibres. Backbone <strong>cables</strong> can<br />
be terminated in an ORP 260 cross-connection<br />
distribution panel in building and floor distributors.<br />
6 <strong>Fibre</strong> <strong>Fibre</strong> <strong>optic</strong> <strong>optic</strong> <strong>cables</strong><br />
7
<strong>Fibre</strong> <strong>optic</strong> <strong>cables</strong><br />
Indoor installation<br />
Outdoor installation<br />
Installation by ploughing<br />
Direct burial installation<br />
wit sand<br />
Duct installation<br />
Installation by air blowing<br />
Aerial installation<br />
Indoor <strong>cables</strong> page<br />
• D • • 3 FMS 10<br />
• D • • 3 FLMS 12<br />
• D • • 3 FLMMS 14<br />
• D • • 3 FTMS 16<br />
• D • • 3 FTMS-600 18<br />
• D • • 3 FY2RMS 20<br />
Indoor/outdoor <strong>cables</strong><br />
• • • • • B • • 3 FZOMSU-SD 22<br />
Duct <strong>cables</strong><br />
• • • • 2 A • • FYO2RMU 24<br />
• • • • 2 A • • FZOMU-SD (<strong>Draka</strong>’s standard colour scheme) 26<br />
• • • • 2 A • FZOHBMU-SD 28<br />
Direct burial <strong>cables</strong><br />
• • • • • A • FYOVD2PMU For trunk lines 30<br />
• • • • • A • FYOVD2PMU K Universal cable 32<br />
• • • • • A • FYOVD2PMU LAN For local area networks 34<br />
• • • • • A • FYO2PMU FTTH drop cable 36<br />
• • • • • A • FZOVDMU-SD 38<br />
• • • • • A • FZOVDMU-SD (<strong>Draka</strong>’s standard colour scheme) 40<br />
Aerial <strong>cables</strong><br />
• • • 1 A • FYOHBMUK 42<br />
• • • 1 A • FYOMUK FTTH drop cable 44<br />
• • • 1 A • • FYOMURK 46<br />
• • • • 1 A • • ADSS 6 kN for 85 m span 48<br />
• • • 1 A • • ADSS 22 kN for 300 m span 50<br />
Underwater <strong>cables</strong><br />
• • • • • A • FYOVMPPMW 52<br />
Aerial installation<br />
1 = Self supporting<br />
2 = Attached to a separate suspension wire<br />
UV resistance<br />
A = good, B = fairly good, C = satisfactory, D = poor<br />
Underwater installation<br />
UV resistance<br />
Fire rating<br />
3 = Flame retardant (IEC 60332-1)<br />
4 = Fire retardant (IEC 60332-3C)<br />
8 <strong>Fibre</strong> <strong>optic</strong> <strong>cables</strong> 9<br />
Non-metallic<br />
Halogen free<br />
Fire rating
<strong>Fibre</strong> <strong>optic</strong> <strong>cables</strong><br />
Indoor cable Type FMS<br />
BBXS<br />
Bend-insensitive BendBright XS fibre<br />
SSTL code Type<br />
FMS<br />
<strong>Draka</strong> code Diameter<br />
mm<br />
Application Tight buffered single fibre cable for patch cords and<br />
other interconnection purposes. Single-mode version<br />
for extended temperature range. Flame retardant and<br />
halogen free.<br />
Construction Optical fibre: Tight coated (0.9 mm) single-mode<br />
BendBright XS or multimode fibre<br />
Strength members: Layer of fibre yarns around the<br />
<strong>optic</strong>al fibre<br />
Sheath: Halogen free and flame retardant plastic<br />
sheath<br />
Sheath colour: SMT-fibre (10/125 µm): yellow<br />
GKT-fibre (62.5/125 µm): orange<br />
GIT-fibre (50/125 µm): green<br />
Properties Temperature range<br />
Transport, storage (single-mode) -40...+70 ºC<br />
Operation (single-mode) -40...+70 ºC<br />
Transport, storage (multimode) -20...+70 ºC<br />
Operation (multimode) -20...+70 ºC<br />
Installation -15...+60 ºC<br />
Crush strength 600 N/100 mm<br />
Allowable<br />
tension N<br />
Bending radius<br />
during installation<br />
mm<br />
Bending radius<br />
installed mm<br />
0241655 1xSMT BBXS 1006288 2.0 100 40 30 4.2<br />
0241601 1xGKT OM1 1006292 2.0 100 40 30 4.2<br />
0241648 1xGIT OM3 1006294 2.0 100 40 30 4.2<br />
Mass<br />
kg/km<br />
10 <strong>Fibre</strong> <strong>optic</strong> <strong>cables</strong> 11<br />
Indoor <strong>cables</strong>
<strong>Fibre</strong> <strong>optic</strong> <strong>cables</strong><br />
Indoor cable<br />
BBXS<br />
Bend-insensitive BendBright XS fibre<br />
SSTL code Type<br />
FLMS<br />
<strong>Draka</strong> code Diameter<br />
mm<br />
Type FLMS<br />
Application Figure-8 zip cord cable with two tight buffered single<br />
fibre FMS <strong>cables</strong>. Suitable for patch cords and other<br />
interconnection purposes. Single-mode version for<br />
extended temperature range. Flame retardant and<br />
halogen free.<br />
Construction Optical fibre: Tight coated (0.9 mm) single-mode<br />
BendBright XS or multimode fibre<br />
Strength members: Layer of fibre yarns around the<br />
<strong>optic</strong>al fibre<br />
Sheath: Halogen free and flame retardant plastic<br />
figure-8 shape sheath<br />
Sheath colour: SMT fibre (10/125 µm): yellow<br />
GKT fibre (62.5/125 µm): orange<br />
GIT fibre (50/125 µm): green<br />
Properties Temperature range<br />
Transport, storage (single-mode) -40...+70 ºC<br />
Operation (single-mode) -40...+70 ºC<br />
Transport, storage (multimode) -20...+70 ºC<br />
Operation (multimode) -20...+70 ºC<br />
Installation -15...+60 ºC<br />
Crush strength 600 N/100 mm<br />
Allowable<br />
tension N<br />
Bending radius<br />
during installation<br />
mm<br />
Bending radius<br />
installed mm<br />
0241657 2xSMT BBXS 1006303 2.0 x 4.0 200 40 30 8.4<br />
0241602 2xGKT OM1 1006222 2.0 x 4.0 200 40 30 8.4<br />
0241606 2xGIT OM3 1006308 2.0 x 4.0 200 40 30 8.4<br />
Mass<br />
kg/km<br />
12 <strong>Fibre</strong> <strong>optic</strong> <strong>cables</strong> 13<br />
Indoor <strong>cables</strong>
<strong>Fibre</strong> <strong>optic</strong> <strong>cables</strong><br />
Indoor cable<br />
BBXS<br />
Bend-insensitive BendBright XS fibre<br />
SSTL code Type<br />
FLMMS<br />
Diameter<br />
mm<br />
Type FLMMS<br />
Application Tight buffered two fibre zip cord cable (FLMS) with<br />
common outer sheath for patch cords and other<br />
interconnection purposes. Flame retardant and<br />
halogen free.<br />
Construction Optical fibre: Tight coated (0.9 mm) single-mode<br />
BendBright XS or multimode fibre<br />
Strength members: Layer of fibre yarns around the<br />
<strong>optic</strong>al fibre<br />
Sheath: Halogen free and flame retardant plastic<br />
sheath<br />
Sheath colour: SMT fibre (10/125 µm): yellow<br />
GKT fibre (62.5/125 µm): orange<br />
GIT fibre (50/125 µm):green<br />
Outer sheath: Halogen free and flame retardant<br />
plastic sheath<br />
Outer sheath colour: SMT fibre (10/125 µm): yellow<br />
GKT fibre (62.5/125 µm): orange<br />
GIT fibre (50/125 µm): green<br />
Properties Temperature range<br />
Transport, storage, operation -20 ... +70 ºC<br />
Installation -15 ... +60 ºC<br />
Crush strength 600 N/100 mm<br />
Allowable<br />
tension N<br />
Bending radius<br />
during installation<br />
mm<br />
Bending radius<br />
installed mm<br />
0241659 2xSMT BBXS 3.0 x 5.0 200 50 40 16<br />
0241603 2xGKT OM1 3.0 x 5.0 200 50 40 16<br />
0241608 2xGIT OM3 3.0 x 5.0 200 50 40 16<br />
Mass<br />
kg/km<br />
14 <strong>Fibre</strong> <strong>optic</strong> <strong>cables</strong> 15<br />
Indoor <strong>cables</strong>
<strong>Fibre</strong> <strong>optic</strong> <strong>cables</strong><br />
Indoor cable<br />
BBXS<br />
Bend-insensitive BendBright XS fibre<br />
SSTL code Type<br />
FTMS<br />
Colour code<br />
Diameter<br />
mm<br />
Type FTMS<br />
Application Tight buffered general purpose installation cable.<br />
Flame retardant and halogen free.<br />
Construction Optical fibre: Tight coated (0.9 mm) single-mode<br />
BendBright XS or multimode fibre<br />
Cable core: <strong>Fibre</strong>s are bundled with fibre yarns to<br />
form the cable core<br />
Outer sheath: Grey halogen free and flame<br />
retardant plastic sheath<br />
Properties Temperature range<br />
Transport, storage, operation -20 ... +70 ºC<br />
Installation -15 ... +60 ºC<br />
Crush strength 2000 N/100 mm<br />
Allowable<br />
tension N<br />
Bending radius<br />
during installation<br />
mm<br />
Bending radius<br />
installed mm<br />
0245583 4xGKT OM1 5.0 1000 150 75 26<br />
0245589 8xGKT OM1 6.0 1000 180 90 35<br />
0245591 12xGKT OM1 6.5 1200 195 98 45<br />
0245585 4xSMT BBXS 5.0 1000 150 35 26<br />
0245587 8xSMT BBXS 6.0 1000 180 45 35<br />
0245593 12xSMT BBXS 6.5 1200 195 50 45<br />
0241614 24xSMT BBXS 8.5 1500 255 65 65<br />
0241624 4xGIT OM3 5.0 1000 150 75 26<br />
0241628 12xGIT OM3 6.5 1200 195 98 45<br />
<strong>Fibre</strong> 1 2 3 4 5 6<br />
Colour red green blue yellow white grey<br />
<strong>Fibre</strong> 7 8 9 10 11 12<br />
Colour brown violet turquoise black orange pink<br />
<strong>Fibre</strong> 13 14 15 16 17 18<br />
Colour yellow white grey turquoise orange pink<br />
black mark 70 mm intervals black mark 70 mm intervals<br />
<strong>Fibre</strong> 19 20 21 22 23 24<br />
Colour yellow white grey turquoise orange pink<br />
black mark 35 mm intervals black mark 35 mm intervals<br />
Mass<br />
kg/km<br />
16 <strong>Fibre</strong> <strong>optic</strong> <strong>cables</strong> 17<br />
Indoor <strong>cables</strong>
<strong>Fibre</strong> <strong>optic</strong> <strong>cables</strong><br />
Indoor cable<br />
BBXS<br />
Bend-insensitive BendBright XS fibre<br />
SSTL code Type<br />
FTMS-600<br />
Colour code<br />
<strong>Draka</strong> code Diameter<br />
mm<br />
<strong>Fibre</strong> 1 2 3 4<br />
Colour red green blue yellow<br />
Type FTMS-600<br />
Application Compact tight buffered (0.6 mm) drop cable for<br />
indoor FTTH installations. Flame retardant and<br />
halogen free. Bend-insensitive BendBright XS fibre<br />
allows low bending radius in final installation.<br />
Construction Optical fibre: Tightly buffered (0.6 mm)<br />
BendBright XS single-mode fibre<br />
Cable core: <strong>Fibre</strong>s are bundled with aramid yarns<br />
to form the cable core<br />
Outer sheath: Grey halogen free and flame<br />
retardant plastic sheath<br />
Properties Temperature range<br />
Transport, storage, operation -20 ...+60 °C<br />
Installation -15 ... +60 °C<br />
Crush strength 500 N/100 mm<br />
Allowable<br />
tension N<br />
Bending radius<br />
during installation<br />
mm<br />
Bending radius<br />
installed mm<br />
0241658 4xSMT BBXS 1014055 3.0 400 N 100 15 8.5<br />
Mass<br />
kg/km<br />
18 <strong>Fibre</strong> <strong>optic</strong> <strong>cables</strong> 19<br />
Indoor <strong>cables</strong>
<strong>Fibre</strong> <strong>optic</strong> <strong>cables</strong><br />
Indoor cable<br />
BBXS<br />
Bend-insensitive BendBright XS fibre<br />
SSTL code Type<br />
FY2RMS<br />
Colour code<br />
<strong>Draka</strong> code Diameter<br />
mm<br />
<strong>Fibre</strong> 1 2 3 4<br />
Colour red green blue yellow<br />
Type FY2RMS<br />
Application Compact FTTH drop cable for indoor installation.<br />
Flame retardant and halogen free. Bendinsensitive<br />
BendBright XS fibre allows low bending<br />
radius in final installation.<br />
Construction Optical fibre: Coloured BendBright XS single-mode<br />
fibre (0.25 mm) in central loose tube<br />
Strength elements: Glass yarns embedded in<br />
sheath<br />
Outer sheath: White halogen free and flame<br />
retardant plastic sheath<br />
Properties Temperature range<br />
Transport, storage, operation -25 ... +50 °C<br />
Installation 0 ... +30 °C<br />
Crush strength 1100 N/100 mm<br />
Allowable<br />
tension N<br />
Bending radius<br />
during installation<br />
mm<br />
Bending radius<br />
installed mm<br />
0241660 4xSML BBXS 1013324 4.2 200 N 60 10 17<br />
Mass<br />
kg/km<br />
20 <strong>Fibre</strong> <strong>optic</strong> <strong>cables</strong> 21<br />
Indoor <strong>cables</strong>
<strong>Fibre</strong> <strong>optic</strong> <strong>cables</strong><br />
Indoor/outdoor cable Type FZOMSU-SD<br />
SSTL code Type<br />
FZOMSU-SD<br />
<strong>Draka</strong> code Diameter<br />
mm<br />
Application Universal non-metallic <strong>optic</strong>al fibre cable for<br />
premises and access networks (drop cable) both<br />
indoor (building backbone) and outdoor applications<br />
(duct installation and direct burial installation with<br />
sand). Semi-dry construction with full water-blocking<br />
properties and for large temperature range. Stranded<br />
loose tube construction with mid-access property.<br />
High fibre counts possible<br />
Construction Optical fibre: Coloured <strong>optic</strong>al single-mode<br />
(ITU-T G.652.D) and/or multimode fibres.<br />
Secondary coating: Thermoplastic loose tube,<br />
fully filled with non-toxic and dermatological safe<br />
compound.<br />
Fillers: Solid plastic fillers, if applicable<br />
Central element: Central element consists of fibre<br />
reinforced plastic (FRP), if applicable covered with a<br />
polyethylene layer to fit into the cable core<br />
Cable core stranding: Loose tubes and fillers are<br />
SZ-stranded around the central element<br />
Longitudinal water tightness: Dry core with water<br />
blocking elements<br />
Sheath: Orange halogen free and flame retardant<br />
plastic jacket, nominal thickness 1.4 mm<br />
Properties Temperature range<br />
Transport, storage, operation -45 ... +70 °C<br />
Installation -15 ... +60 °C<br />
Crush strength 1500 N/100 mm<br />
Allowable<br />
tension N<br />
Bending radius<br />
during installation/<br />
installed mm<br />
Mass<br />
kg/km<br />
Drum/standard<br />
delivery length<br />
km<br />
0241906 6xSML 1006340 10.0 1500 200/120 80 K12/4<br />
0242747 2x6xSML 1005332 10.0 1500 200/120 80 K12/4<br />
0241914 4x6xSML 1005333 10.0 1500 200/120 80 K12/4<br />
0242749 4x2x6xSML 1005462 13.0 1500 260/160 125 K16/4<br />
0241928 8x2x6xSML 1008965 15.0 1650 300/180 165 K20/4<br />
0241936 16x2x6xSML 1005774 19.0 2650 380/230 265 K22/4<br />
0242753 4xGKL OM1 1006260 10.0 1500 200/120 80 K12/4<br />
0242755 2x4xGKL OM1 1006262 10.0 1500 200/120 80 K12/4<br />
0242757 2x6xGKL OM1 1006263 10.0 1500 200/120 80 K12/4<br />
0242759 4x6xGKL OM1 1006264 10.0 1500 200/120 80 K12/4<br />
SSTL code Type<br />
FZOMSU-SD-Y<br />
<strong>Draka</strong> code Diameter<br />
mm<br />
Allowable<br />
tension N<br />
Bending radius<br />
during installation/<br />
istalled mm<br />
Mass<br />
kg/km<br />
Drum/standard<br />
delivery length<br />
km<br />
0242771 4xSML+4xGKL OM1 1006343 10.0 1500 200/120 80 K12/4<br />
0242773 4xSML+2x4xGKL OM1 1006267 10.0 1500 200/120 80 K12/4<br />
0242775 2x4xSML+2x4xGKL OM1 1006268 10.0 1500 200/120 80 K12/4<br />
0242777 2x6xSML+2x6xGKL OM1 1006269 10.0 1500 200/120 80 K12/4<br />
0241939 6xSML+6xGIL OM3 1014665 10.0 1500 200/120 80 K12/4<br />
0241938 2x6xSML+2x6xGIL OM3 1013017 10.0 1500 200/120 80 K12/4<br />
22 <strong>Fibre</strong> <strong>optic</strong> <strong>cables</strong> 23<br />
Indoor/outdoor cable
<strong>Fibre</strong> <strong>optic</strong> <strong>cables</strong><br />
Duct cable Type FYO2RMU<br />
SSTL code Type<br />
FYO2RMU<br />
<strong>Draka</strong> code Diameter<br />
mm<br />
Application Non-metallic <strong>optic</strong>al fibre cable for duct and<br />
direct burial installation with sand. Suitable for<br />
installation by pulling or air blowing. Extra high<br />
crush strength. Also for premises networks.<br />
Construction Optical fibre: Coloured <strong>optic</strong>al single-mode fibre<br />
Secondary coating: Plastic core with a jelly-filled<br />
helical channel for the fibres. Spiral Space ®<br />
design.<br />
Wrapping: Cable core is surrounded with water-<br />
blocking elements<br />
Strength members: Two fibre reinforced plastic<br />
(FRP) rods in the outer sheat, nominal diameter<br />
1.6 mm<br />
Outer sheath: The cable sheath consists of UV<br />
resistant black polyethylene compound, nominal<br />
thickness 2.9 mm.<br />
Properties Temperature range<br />
Transport, storage, operation -45 ... +70 ºC<br />
Installation -15 ... +60 ºC<br />
Crush strength 5000 N/100 mm<br />
Allowable<br />
tension N<br />
Bending radius<br />
during installation/<br />
installed mm<br />
Mass<br />
kg/km<br />
Drum/standard<br />
delivery length<br />
km<br />
0242272 2x6xSML 1005376 11.5 1500 230/175 105 K16/6<br />
0242276 4x6xSML 1005378 12.5 1500 250/190 125 K18/6<br />
0242282 2x4x6xSML 1005381 13.5 1500 270/205 145 K18/6<br />
0242288 4x4x6xSML 1005384 14.5 1700 290/220 170 K20/6<br />
24 <strong>Fibre</strong> <strong>optic</strong> <strong>cables</strong> 25<br />
Duct <strong>cables</strong>
<strong>Fibre</strong> <strong>optic</strong> <strong>cables</strong><br />
Duct cable<br />
SSTL code Type<br />
FZOMU-SD<br />
Structure Diameter<br />
mm<br />
Type FZOMU-SD<br />
Application Non-metallic <strong>optic</strong>al fibre cable for duct installations.<br />
Suitable for installation by pulling or air blowing.<br />
Stranded loose tube construction with mid-access<br />
property. Semi-dry construction with full water<br />
blocking properties and for large temperature range.<br />
High fibre counts possible.<br />
Construction Optical fibre Coloured <strong>optic</strong>al single-mode fibre<br />
(ITU-T G.652.D)<br />
Secondary coating: Thermoplastic loose tube,<br />
fully filled with non-toxic and dermatological safe<br />
compound.<br />
Fillers: Solid plastic fillers, if applicable<br />
Central element: Central element consists of fibre<br />
reinforced plastic (FRP), if applicable covered with a<br />
polyethylene layer to fit into the cable core<br />
Cable core stranding: Loose tubes and fillers are<br />
SZ-stranded around the central element<br />
Longitudinal water tightness: Dry core with water<br />
blocking elements<br />
Sheath: Black UV resistant polyethylene sheath,<br />
nominal thickness 1.5 mm<br />
Properties Temperature range<br />
Transport, storage, operation -40 ... +70 °C<br />
Installation -15 ... +60 °C<br />
Crush strength 3000 N/100 mm<br />
Allowable<br />
tension N<br />
Bending radius<br />
during installation/<br />
installed mm<br />
Mass<br />
kg/km<br />
Drum/standard<br />
delivery length<br />
km<br />
0243100 12xSML 1x12 11.0 2700 220/110 85 K16/6<br />
0243101 24xSML 2x12 11.0 2700 220/110 85 K16/6<br />
0243102 48xSML 4x12 11.0 2700 220/110 85 K16/6<br />
0243103 96xSML 8x12 12.5 2700 250/125 120 K18/6<br />
0243104 192xSML 16x12 16.5 2700 330/165 190 K22/6<br />
0243105 288xSML 24x12 18.5 2700 370/185 250 K24/6<br />
0243106 384xSML 32x12 21.5 3300 430/215 330 K22/4<br />
0243107 480xSML 20x24 19.5 2750 390/195 275 K21/4<br />
0243108 576xSML 24x24 21.5 3350 430/215 335 K22/4<br />
0243109 672xSML 28x24 25.0 4450 500/250 445 K24/4<br />
0243110 720xSML 30x24 25.0 4450 500/250 445 K24/4<br />
Colour code<br />
<strong>Fibre</strong> 1 2 3 4 5 6 7 8 9 10 11 12<br />
Colour blue yellow red white green violet orange grey turquoise black brown pink<br />
<strong>Fibre</strong> 13 14 15 16 17 18 19 20 21 22 23 24<br />
Colour blue yellow red white green orange turquoise pink natural blue yellow red<br />
black mark 50 mm intervals black mark 25 mm intervals<br />
26 <strong>Fibre</strong> <strong>optic</strong> <strong>cables</strong> 27<br />
Duct <strong>cables</strong>
<strong>Fibre</strong> <strong>optic</strong> <strong>cables</strong><br />
Duct cable<br />
SSTL code Type<br />
FZOHBMU-SD<br />
<strong>Draka</strong> code Diameter<br />
mm<br />
Type FZOHBMU-SD<br />
Application Optical fibre cable for duct installations. Suitable<br />
for installation by pulling or air blowing. Stranded<br />
loose tube construction with mid-access<br />
property. Semi-dry construction with full water<br />
blocking properties and for large temperature<br />
range. High fibre counts possible.<br />
Construction Optical fibre: Coloured <strong>optic</strong>al single-mode fibre<br />
(ITU-T G.652.D)<br />
Secondary coating: Thermoplastic loose tube,<br />
fully filled with non-toxic and dermatological<br />
safe compound.<br />
Fillers: Solid plastic fillers, if applicable<br />
Central element: Central element consists<br />
of fibre reinforced plastic (FRP), if applicable<br />
covered with a polyethylene layer to fit into the<br />
cable core<br />
Cable core stranding: Loose tubes and fillers are<br />
SZ-stranded around the central element<br />
Longitudinal water tightness: Dry core with<br />
water blocking elements<br />
Moisture barrier: Aluminium tape coated with<br />
a copolymer of polyethylene on both sides is<br />
applied longitudinally with an overlap, minimum<br />
overlap 3.0 mm<br />
Sheath: Black UV resistant polyethylene sheath,<br />
nominal thickness 1.5 mm<br />
Properties Temperature range<br />
Transport, storage, operation -45 ... +70 °C<br />
Installation -15 ... +70 °C<br />
Crush strength 3000 N/100 mm<br />
Allowable<br />
tension N<br />
Bending radius<br />
during installation/<br />
installed mm<br />
Mass<br />
kg/km<br />
Drum/standard<br />
delivery length<br />
km<br />
0243051 2x6xSML 1005342 12.5 1500 250/190 130 K14/4<br />
0243053 4x6xSML 1005344 12.5 1500 250/190 130 K18/6<br />
0243056 8x6xSML 1005347 15.0 1700 300/220 170 K20/6<br />
0243058 8x2x6xSML 1005349 17.0 2100 340/260 210 K20/4<br />
0243060 16x2x6xSML 1005351 21.5 3200 400/300 320 K22/4<br />
28 <strong>Fibre</strong> <strong>optic</strong> <strong>cables</strong> 29<br />
Duct <strong>cables</strong>
<strong>Fibre</strong> <strong>optic</strong> <strong>cables</strong><br />
Direct buried cable for trunk lines Type FYOVD2PMU<br />
SSTL code Type<br />
FYOVD2PMU<br />
<strong>Draka</strong> code Diameter<br />
mm<br />
Application Universal <strong>optic</strong>al fibre cable for duct or direct<br />
burial installations. Also for arctic climate when<br />
the soil with stones around the cable can be<br />
frozen. Extra high crush strength. Suitable<br />
for direct burial by ploughing. Crew friendly<br />
installation. Rodent protected.<br />
Construction Optical fibre: Coloured <strong>optic</strong>al single-mode fibre<br />
(ITU-T G.652.D)<br />
Secondary coating: Plastic core with a jelly-filled<br />
helical coating channel for the fibres. Spiral<br />
Space ® design.<br />
Wrapping: Cable core is wrapped longitudinally<br />
with swelling tape<br />
Protection: Corrugated steel tape coated with<br />
a copolymer of polyethylene on both sides is<br />
applied longitudinally with an overlap. Minimum<br />
overlap is 3.0 mm. The nominal thickness of the<br />
steel tape is 0.15 mm.<br />
Strength members: Two high tensile strength<br />
steel wires in the outer sheath, diameter 2.12<br />
mm.<br />
Outer sheath: Cable sheath consists of UV<br />
resistant black polyethylene compound nominal<br />
thickness 2.4 mm.<br />
Properties Temperature range<br />
Transport, storage, operation -45 ... +70 ºC<br />
Installation -15 ... +60 ºC<br />
Allowable<br />
tension N<br />
Crush strength 6000 N/100 mm Direct buried <strong>cables</strong><br />
Bending radius<br />
during installation/<br />
installed mm<br />
Mass<br />
kg/km<br />
Drum/standard<br />
delivery length<br />
km<br />
0242704 6xSML 1005303 15.5 5000 340/235 230 K20/6<br />
0242708 2x6xSML 1005304 15.5 5000 340/235 230 K20/6<br />
0242712 4x6xSML 1005305 16.5 5000 415/250 260 K22/6<br />
0242718 2x4x6xSML 1005306 17.5 5000 440/265 290 K22/6<br />
0242724 4x4x6xSML 1005307 18.5 5000 465/280 320 K22/4<br />
30 <strong>Fibre</strong> <strong>optic</strong> <strong>cables</strong> 31
<strong>Fibre</strong> <strong>optic</strong> <strong>cables</strong><br />
Universal direct buried cable Type FYOVD2PMU K<br />
SSTL code Type<br />
FYOVD2PMU K<br />
<strong>Draka</strong> code Diameter<br />
mm<br />
Application Universal <strong>optic</strong>al fibre cable for duct or direct<br />
burial installations. Also for arctic climate when<br />
the soil around the cable can be frozen. Extra<br />
high crush strength. Suitable for direct burial<br />
by ploughing. Crew friendly installation. Rodent<br />
protected.<br />
Construction Optical fibre: Coloured <strong>optic</strong>al single-mode fibre<br />
(ITU-T G.652.D)<br />
Secondary coating: Plastic core with a jelly-filled<br />
helical coating channel for the fibres. Spiral<br />
Space ® design.<br />
Wrapping: Cable core is wrapped longitudinally<br />
with swelling tape<br />
Protection: Corrugated steel tape coated with<br />
a copolymer of polyethylene on both sides is<br />
applied longitudinally with an overlap. Minimum<br />
overlap is 3.0 mm. The nominal thickness of the<br />
steel tape is 0.15 mm.<br />
Strength members: Two high tensile strength<br />
steel wires in the outer sheath, diameter 1.6<br />
mm.<br />
Outer sheath: Cable sheath consists of UV<br />
resistant black polyethylene compound, nominal<br />
thickness 2.4 mm.<br />
Properties Temperature range<br />
Transport, storage, operation -45 ... +70 ºC<br />
Installation -15 ... +60 ºC<br />
Crush strength 6000 N/100 mm<br />
Allowable<br />
tension N<br />
Bending radius<br />
during installation/<br />
installed mm<br />
Mass<br />
kg/km<br />
Drum/standard<br />
delivery length<br />
km<br />
0242730 6xSML 1005308 14.0 5000 280/140 180 K20/6<br />
0242734 2x6xSML 1005309 14.0 5000 280/140 180 K20/6<br />
0242738 4x6xSML 1005310 14.0 5000 280/140 180 K20/6<br />
0242743 2x4x6xSML 1005311 16.0 5000 300/160 230 K22/6<br />
0242926 4x4x6xSML 1005312 17.5 5000 300/180 275 K22/6<br />
32 <strong>Fibre</strong> <strong>optic</strong> <strong>cables</strong> 33<br />
Direct buried <strong>cables</strong>
<strong>Fibre</strong> <strong>optic</strong> <strong>cables</strong><br />
Direct buried cable for local area networks Type FYOVD2PMU LAN<br />
SSTL code Type<br />
FYOVD2PMU<br />
<strong>Draka</strong> code Diameter<br />
mm<br />
Application Universal <strong>optic</strong>al fibre cable for duct or direct<br />
burial installations. Also for arctic climate when<br />
the soil around the cable can be frozen. Extra<br />
high crush strength. Suitable for direct burial<br />
by ploughing. Crew friendly installation. Rodent<br />
protected. Especially for premises networks<br />
Construction Optical fibre: Coloured <strong>optic</strong>al single-mode fibre<br />
(ITU-T G.652.D) and/or multimode fibre<br />
Secondary coating: Plastic core with a jelly-filled<br />
helical coating channel for the fibres. Spiral<br />
Space ® design.<br />
Wrapping: Cable core is wrapped longitudinally<br />
with swelling tape<br />
Protection: Corrugated steel tape coated with<br />
a copolymer of polyethylene on both sides is<br />
applied longitudinally with an overlap. Minimum<br />
overlap is 3.0 mm. The nominal thickness of the<br />
steel tape is 0.15 mm.<br />
Strength members: Two high tensile strength<br />
steel wires in the outer sheath, diameter 1.6 mm.<br />
Outer sheath: Cable sheath consists of UV<br />
resistant black polyethylene compound, nominal<br />
thickness 2.4 mm.<br />
Properties Temperature range<br />
Transport, storage, operation -45 ... +70 ºC<br />
Installation -15 ... +60 ºC<br />
Crush strength 6000 N/100 mm<br />
Allowable<br />
tension N<br />
Bending radius<br />
during installation/<br />
installed mm<br />
Mass<br />
kg/km<br />
Drum/standard<br />
delivery length<br />
km<br />
0242304 4xGKL OM1 1005313 14.0 3500 280/210 180 K16/4<br />
0242308 2x4xGKL OM1 1005314 14.0 3500 280/210 180 K16/4<br />
0242312 2x6xGKL OM1 1005315 14.0 3500 280/210 180 K16/4<br />
0242314 4x6xGKL OM1 1005316 15.0 3500 300/225 205 K16/4<br />
SSTL code Type<br />
FYOVD2PMU-Y<br />
<strong>Draka</strong> code Diameter<br />
mm<br />
Allowable<br />
tension N<br />
Bending radius<br />
during installation/<br />
installed mm<br />
Mass<br />
kg/km<br />
Drum/standard<br />
delivery length<br />
km<br />
0242740 4xSML+4xGKL OM1 1005317 14.0 3500 280/210 180 K16/4<br />
0242742 4xSML+2x4xGKL OM1 1005318 14.0 3500 280/210 180 K16/4<br />
0242744 2x4xSML+2x4xGKL OM1 1005319 15.0 3500 300/225 205 K16/4<br />
0242746 2x6xSML+2x6xGKL OM1 1005434 15.0 3500 300/225 205 K16/4<br />
34 <strong>Fibre</strong> <strong>optic</strong> <strong>cables</strong> 35<br />
Direct buried <strong>cables</strong>
<strong>Fibre</strong> <strong>optic</strong> <strong>cables</strong><br />
FTTH-drop cable Type FYO2PMU<br />
SSTL code Type<br />
FYO2PMU<br />
<strong>Draka</strong> code Diameter<br />
mm<br />
Application Universal <strong>optic</strong>al fibre cable for FTTH drop<br />
applications for direct burial or duct installations.<br />
Suitable for installations by ploughing, pulling,<br />
pushing or air blowing. Especially for connecting<br />
single family house to <strong>optic</strong>al access network.<br />
Central tube construction, Spiral Space ® design,<br />
for max 12 fibres. Extra high crush strength.<br />
Construction Optical fibre: Coloured <strong>optic</strong>al single-mode fibre<br />
(ITU-T G.652.D)<br />
Secondary coating: Plastic core with a jelly-filled<br />
helical coating channel for the fibres. Spiral<br />
Space ® design.<br />
Wrapping: Cable core is wrapped with water-<br />
blocking elements<br />
Protection: Corrugated steel tape coated with<br />
a copolymer of polyethylene on both sides is<br />
applied longitudinally with an overlap. Minimum<br />
overlap is 3.0 mm. The nominal thickness of the<br />
steel tape is 0.15 mm.<br />
Strength members: Two high tensile strength<br />
steel wires in the outer sheath, diameter 1.2 mm.<br />
Outer sheath: Cable sheath consists of UV<br />
resistant black polyethylene compound, nominal<br />
thickness 1.5 mm.<br />
Properties Temperature range<br />
Transport, storage, operation -45 ... +70 ºC<br />
Installation -15 ... +60 ºC<br />
Crush strength 5000 N/100 mm<br />
Allowable<br />
tension N<br />
Bending radius<br />
during installation/<br />
installed mm<br />
Mass<br />
kg/km<br />
Drum/standard<br />
delivery length<br />
km<br />
0242074 4xSML 1005364 9.0 3500 180/110 80 K14/6<br />
0242076 6xSML 1005365 9.0 3500 180/110 80 K14/6<br />
0242081 2x6xSML 1005367 9.0 3500 180/110 80 K14/6<br />
36 <strong>Fibre</strong> <strong>optic</strong> <strong>cables</strong> 37<br />
Direct buried <strong>cables</strong>
<strong>Fibre</strong> <strong>optic</strong> <strong>cables</strong><br />
Direct buried cable Type FZOVDMU-SD<br />
SSTL code Type<br />
FZOVDMU-SD<br />
<strong>Draka</strong> code Diameter<br />
mm<br />
Application Optical fibre cable for direct burial and duct<br />
installations. Suitable for direct burial installation<br />
by ploughing pulling or duct installation by pulling.<br />
Stranded loose tube construction with mid-access<br />
property. Semi-dry construction with full water<br />
blocking properties and for large temperature<br />
range.<br />
Construction Optical fibre: Coloured <strong>optic</strong>al single-mode fibre<br />
(ITU-T G.652.D)<br />
Secondary coating: Thermoplastic loose tube,<br />
fully filled with non-toxic and dermatological safe<br />
compound.<br />
Fillers: Solid plastic fillers, if applicable<br />
Central element: Central element consists of fibre<br />
reinforced plastic (FRP), if applicable covered with<br />
a polyethylene layer to fit into the cable core<br />
Cable core stranding: Loose tubes and fillers are<br />
SZ-stranded around the central element<br />
Longitudinal water tightness: Dry core with water<br />
blocking elements<br />
Protection: Corrugated steel tape coated with a<br />
copolymer of polyethylene on both sides is applied<br />
longitudinally with an overlap. Minimum overlap is<br />
3.0 mm. The nominal thickness of the steel tape is<br />
0.15 mm.<br />
Sheath: Black UV resistant HPDE sheath, minimum<br />
thickness 1.2 mm<br />
Properties Temperature range<br />
Transport, storage, operation -45 ... +70 °C<br />
Installation -15 ... +70 °C<br />
Crush strength 4000 N/100 m<br />
Allowable<br />
tension N<br />
Bending radius<br />
during installation/<br />
installed mm<br />
Mass<br />
kg/km<br />
Drum/standard<br />
delivery length<br />
km<br />
0242701 2x6xSML 1005353 16.0 3500 250/190 210 K20/6<br />
0240242 4x6xSML 1005355 16.0 3500 250/190 210 K20/6<br />
0242705 8x6xSML 1005358 18.0 3500 280/210 260 K22/4<br />
0242707 8x2x6xSML 1005360 19.0 3500 320/240 280 K22/4<br />
0242709 16x2x6xSML 1005362 23.0 3500 400/300 400 K22/3<br />
38 <strong>Fibre</strong> <strong>optic</strong> <strong>cables</strong> 39<br />
Direct buried <strong>cables</strong>
<strong>Fibre</strong> <strong>optic</strong> <strong>cables</strong><br />
Direct buried cable (high fibre count)<br />
SSTL code Type<br />
FZOVDMU-SD<br />
Structure Diameter<br />
mm<br />
Type FZOVDMU-SD<br />
Application High fibre count <strong>optic</strong>al fibre cable for direct burial<br />
and duct installations. Suitable for direct burial<br />
installation by ploughing pulling or duct installation<br />
by pulling. Stranded loose tube construction<br />
with mid-access property. Semi-dry construction<br />
with full water blocking properties and for large<br />
temperature range.<br />
Construction Optical fibre: Coloured <strong>optic</strong>al single-mode fibre<br />
(ITU-T G.652.D)<br />
Secondary coating: Thermoplastic loose tube<br />
containing 12 or 24 fibres, fully filled with nontoxic<br />
and dermatological safe compound.<br />
Fillers: Solid plastic fillers, if applicable<br />
Central element: Central element consists of fibre<br />
reinforced plastic (FRP), if applicable covered with<br />
a polyethylene layer to fit into the cable core<br />
Cable core stranding: Loose tubes and fillers are<br />
SZ-stranded around the central element in two<br />
layers<br />
Longitudinal water tightness: Dry core with water<br />
blocking elements<br />
Protection: Corrugated steel tape coated with a<br />
copolymer of polyethylene on both sides is applied<br />
longitudinally with an overlap. Minimum overlap is<br />
3.0 mm. The nominal thickness of the steel tape is<br />
0.15 mm.<br />
Sheath: Black UV resistant PE sheath, nominal<br />
thickness 1.5 mm<br />
Properties Temperature range<br />
Transport, storage, operation -45 ... +70 °C<br />
Installation -15 ... +70 °C<br />
Crush strength 4000 N/100 mm<br />
Allowable<br />
tension N<br />
Bending radius<br />
during installation/<br />
installed mm<br />
Mass<br />
kg/km<br />
Drum/standard<br />
delivery length<br />
km<br />
0243035 192xSML 16x12 18.0 2700 380/270 285 K20/4<br />
0243036 288xSML 24x12 20.5 3400 410/310 365 K22/4<br />
0243037 384xSML 32x12 26.5 5400 530/400 560 K20/2<br />
0243038 480xSML 20x24 22.0 3800 440/330 395 K18/2<br />
0243039 576xSML 24x24 24.0 4500 480/360 465 K20/2<br />
0243040 672xSML 28x24 27.0 5700 540/410 590 K20/2<br />
0243041 720xSML 30x24 27.0 5700 540/410 590 K20/2<br />
Colour code<br />
<strong>Fibre</strong> 1 2 3 4 5 6 7 8 9 10 11 12<br />
Colour blue yellow red white green violet orange grey turquoise black brown pink<br />
<strong>Fibre</strong> 13 14 15 16 17 18 19 20 21 22 23 24<br />
Colour blue yellow red white green orange turquoise pink natural blue yellow red<br />
black mark 50 mm intervals black mark 25 mm intervals<br />
40 <strong>Fibre</strong> <strong>optic</strong> <strong>cables</strong> 41<br />
Direct buried <strong>cables</strong>
<strong>Fibre</strong> <strong>optic</strong> <strong>cables</strong><br />
Aerial cable Type FYOHBMUK<br />
SSTL code Type<br />
FYOHBMUK<br />
<strong>Draka</strong> code Diameter<br />
mm<br />
Application Self-supporting figure-8 shape aerial cable. Large<br />
temperature range. Also for arctic climate with heavy<br />
ice or wind loads up to span lengths 90 m. Crew<br />
friendly splicing. Extra high crush strength.<br />
Construction Optical fibre: Coloured <strong>optic</strong>al single-mode fibres<br />
(ITU-T G.652.D)<br />
Secondary coating: Plastic core with a jelly-filled<br />
helical channel for the fibres. Spiral Space ® design.<br />
Wrapping: Cable core is wrapped longitudinally with<br />
swelling tape<br />
Moisture barrier: Aluminium tape coated with a<br />
copolymer of polyethylene on both sides is applied<br />
longitudinally with an overlap. Minimum overlap is<br />
3.0 mm.<br />
Suspension: Suspension wire is made of stranded<br />
galvanized steel wires, nominal dimension 7 x 1.6<br />
mm or 7 x 2.1 mm.<br />
Outer sheath: Cable sheath consists of UV resistant<br />
black polyethylene compound in figure-8 shape,<br />
nominal thickness 1.2 mm.<br />
Properties Temperature range<br />
Transport, storage, operation -45 ... +70 ºC<br />
Installation -15 ... +60 ºC<br />
Crush Strength 5000 N/100 mm<br />
Maximum ice load 3.0 kg/m<br />
Maximum span length 7 x 1.6<br />
suspension wire 60 m<br />
7 x 2.1<br />
suspension wire 90 m<br />
Allowable<br />
tension N<br />
Bending radius<br />
during installation/<br />
installed mm<br />
Mass<br />
kg/km<br />
Drum/standard<br />
delivery length<br />
km<br />
Suspension wire 7 x 1.6 mm<br />
0242502 6xSML 1005395 11 x 22 7000 300/150 240 K20/6<br />
0242506 2x6xSML 1005397 11 x 22 7000 300/150 240 K20/6<br />
0242510 4x6xSML 1005399 12 x 23 7000 300/180 260 K22/6<br />
0242516 2x4x6xSML 1005402 13 x 24 7000 300/200 280 K18/3<br />
0242522 4x4x6xSML 1005405 13 x 24 7000 300/200 290 K18/3<br />
Suspension wire 7 x 2.1 mm<br />
0242528 6xSML 1005407 11 x 23 12000 300/150 340 K21/6<br />
0242532 2x6xSML 1005409 11 x 23 12000 300/150 340 K21/6<br />
0242536 4x6xSML 1005411 12 x 24 12000 300/180 360 K16/3<br />
0242542 2x4x6xSML 1005414 13 x 25 12000 300/200 380 K18/3<br />
0242548 4x4x6xSML 1005417 13 x 25 12000 300/200 380 K18/3<br />
42 <strong>Fibre</strong> <strong>optic</strong> <strong>cables</strong> 43<br />
Aerial <strong>cables</strong>
<strong>Fibre</strong> <strong>optic</strong> <strong>cables</strong><br />
Aerial FTTH-drop cable Type FYOMUK<br />
SSTL code Type<br />
FYOMUK<br />
Additional load<br />
kg/m<br />
Diameter<br />
mm<br />
Sag<br />
m<br />
Application Self-supporting figure-8 shape aerial cable for<br />
FTTH drop applications. Especially for connecting<br />
single family house to <strong>optic</strong>al access network.<br />
Also for arctic climate with heavy ice or wind<br />
loads. Large temperature range. Crew friendly<br />
splicing. Extra high crush strength. Central tube<br />
construction, Spiral Space ® design, for max 12<br />
fibres.<br />
Construction Optical fibre: Coloured <strong>optic</strong>al single-mode fibre<br />
(ITU-T G.652.D)<br />
Secondary coating: Plastic core with a jelly-filled<br />
helical channel for the fibres. Spiral Space ®<br />
design.<br />
Wrapping: Cable core is wrapped with water<br />
swelling elements<br />
Suspension: Suspension wire is made of stranded<br />
galvanized steel wires, nominal dimension 7 x 1.0.<br />
Outer sheath: The cable sheath consists of UV<br />
resistant black polyethylene compound in figure-8<br />
shape, nominal thickness 1.2 mm.<br />
Properties Temperature range<br />
Transport, storage, operation -45 ... +70 ºC<br />
Installation -15 ... +60 ºC<br />
Crush Strength 5000 N/100 mm<br />
Span 30 m Span 40 m Span 50 m<br />
Load<br />
N<br />
Allowable<br />
tension N<br />
0 0.2 500 0.4 500 0.6 500<br />
0.8 0.6 1600 1.0 1900 1.3 2100<br />
2.5 1.0 3100 1.4 3700 1.9 4200<br />
44 <strong>Fibre</strong> <strong>optic</strong> <strong>cables</strong> 45<br />
Sag<br />
m<br />
Bending radius<br />
during installation/<br />
installed mm<br />
Load<br />
N<br />
Mass<br />
kg/km<br />
Sag<br />
m<br />
Drum/standard<br />
delivery length<br />
km<br />
<strong>cables</strong><br />
Aerial<br />
0243002 4xSML 7.5 x 14.0 1600 250/150 105 K14/6<br />
0240003 6xSML 7.5 x 14.0 1600 250/150 105 K14/6<br />
0243004 2x4xSML 7.5 x 14.0 1600 250/150 105 K14/6<br />
0243005 2x6xSML 7.5 x 14.0 1600 250/150 105 K14/6<br />
Installation data (at 0 °C )<br />
Load<br />
N
<strong>Fibre</strong> <strong>optic</strong> <strong>cables</strong><br />
Non-Metallic aerial cable Type FYOMURK<br />
SSTL code Type<br />
FYOMURK<br />
Diameter<br />
mm<br />
Application Self-supporting figure-8 shape non-metallic aerial<br />
cable. Large temperature range. Crew friendly<br />
splicing. Extra high crush strength.<br />
Construction Optical fibre: Coloured <strong>optic</strong>al single-mode fibre<br />
(ITU-T G.652.D)<br />
Secondary coating: Plastic core with a jelly-filled<br />
helical channel for the fibres. Spiral Space ®<br />
design.<br />
Wrapping: Cable core is covered with a waterblocking<br />
layer.<br />
Suspension: Suspension wire is made of fibre<br />
reinforced plastic (FRP) rod, nominal diameter<br />
4.5 mm.<br />
Outer sheath: The cable sheath consists of UV<br />
resistant black polyethylene compound in figure-8<br />
shape, minimum sheath thickness 1.1 mm.<br />
Properties Temperature range<br />
Transport, storage, operation -45 ... +70 ºC<br />
Installation -15 ... +60 ºC<br />
Crush Strength 5000 N/100 mm<br />
Maximum ice load 3.0 kg/m<br />
Maximum span length 50 m<br />
Allowable<br />
tension N<br />
Bending radius<br />
during installation/<br />
installed mm<br />
Mass<br />
kg/km<br />
Drum/standard<br />
delivery length<br />
km<br />
0242554 6xSM 11.0 x 22.0 4000 600/150 170 K16/3<br />
0242558 2x6xSML 11.0 x 22.0 4000 600/150 170 K16/3<br />
0242562 4x6xSML 11.0 x 23.0 4000 600/180 190 K16/3<br />
0242568 2x4x6xSML 11.0 x 24.0 4000 600/250 210 K16/3<br />
46 <strong>Fibre</strong> <strong>optic</strong> <strong>cables</strong> 47<br />
Aerial <strong>cables</strong>
<strong>Fibre</strong> <strong>optic</strong> <strong>cables</strong><br />
Non-Metallic aerial cable<br />
SSTL code Type<br />
ADSS 6kN<br />
Diameter<br />
mm<br />
Type ADSS 6kN<br />
Application Round all-dielectric self-supporting aerial cable<br />
to be installed into overhead power lines. Also for<br />
arctic climate with heavy ice or wind loads up to<br />
span lengths 85 m. Large temperature range.<br />
Construction Optical fibre: Coloured <strong>optic</strong>al single-mode fibre<br />
(ITU-T G.652.D)<br />
Secondary coating: Thermoplastic loose tube<br />
containing 6 or 12 fibres, fully filled with non-toxic<br />
and dermatological safe compound.<br />
Fillers: Solid plastic fillers, if applicable.<br />
Central element: Central element consists of fibre<br />
reinforced plastic (FRP), if applicable covered with<br />
a polyethylene layer to fit into the cable core.<br />
Cable core stranding: Loose tubes and fillers are<br />
SZ-stranded around the central element<br />
Longitudinal water tightness: Cable core is filled<br />
with filling compound<br />
Inner sheath : Black homogeneous weather<br />
resistant polyethylene sheath<br />
Peripheral strength element: Layer of aramid yarns<br />
Outer sheath: Black homogeneous weather<br />
resistant polyethylene sheath<br />
Properties Temperature range<br />
Transport, storage, operation -45 ... +60 °C<br />
Installation -15 ... +60 °C<br />
Crush strength 1500 N/100 mm<br />
Max. ice load 3.0 kg/m<br />
Max. span 85 m<br />
Allowable<br />
tension N<br />
Bending radius<br />
during installation/<br />
installed mm<br />
Mass<br />
kg/km<br />
Drum/standard<br />
delivery length<br />
km<br />
0242596 2x6xSML 12.7 6000 260/200 140 K16/4<br />
0242597 4x6xSML 12.7 6000 260/200 140 K16/4<br />
0242595 8x6xSML 14.2 6000 290/220 170 K16/4<br />
0242598 8x2x6xSML 14.5 6000 290/220 175 K16/4<br />
48 <strong>Fibre</strong> <strong>optic</strong> <strong>cables</strong> 49<br />
Aerial <strong>cables</strong>
<strong>Fibre</strong> <strong>optic</strong> <strong>cables</strong><br />
Non-Metallic aerial cable<br />
SSTL code Type<br />
ADSS 22kN<br />
Diameter<br />
mm<br />
Type ADSS 22kN<br />
Application Round all-dielectric self-supporting aerial cable<br />
to be installed into overhead power lines. Also for<br />
arctic climate with heavy ice or wind loads up to<br />
span lengths 300 m. Large temperature range.<br />
Construction Optical fibre: Coloured <strong>optic</strong>al single-mode fibre<br />
(ITU-T G.652.D)<br />
Secondary coating: Thermoplastic loose tube<br />
containing 12 fibres, fully filled with non-toxic and<br />
dermatological safe compound.<br />
Fillers: Solid plastic fillers<br />
Central element: Central element consists of fibre<br />
reinforced plastic (FRP), if applicable covered with<br />
a polyethylene layer to fit into the cable core.<br />
Cable core stranding: Loose tubes and fillers are<br />
stranded around the central element<br />
Longitudinal water tightness: Cable core is filled<br />
with filling compound<br />
Inner sheath: Black homogeneous weather<br />
resistant polyethylene sheath<br />
Peripheral strength element: Layer of aramid yarns<br />
Outer sheath: Black homogeneous weather<br />
resistant polyethylene sheath<br />
Properties Temperature range<br />
Transport, storage, operation -40 ... +70 °C<br />
Installation -15 ... +60 °C<br />
Crush strength 2000 N/100 mm<br />
Max. ice load 2.5 kg/m<br />
Max. span 300 m<br />
Allowable<br />
tension N<br />
Bending radius<br />
during installation/<br />
installed mm<br />
Mass<br />
kg/km<br />
Drum/standard<br />
delivery length<br />
km<br />
0242480 12xSML 15.8 22000 320/240 192 K18/4<br />
0242481 2x12xSML 15.8 22000 320/240 192 K18/4<br />
0242482 4x12xSML 15.8 22000 320/240 192 K18/4<br />
0242483 8x12xSML 17.4 22000 350/260 225 K20/4<br />
Colour code<br />
<strong>Fibre</strong> 1 2 3 4 5 6 7 8 9 10 11 12<br />
Colour blue yellow red white green violet orange grey turquoise black brown pink<br />
Tube 1 2 3 4 5 6 7 8 9 10 11 12<br />
Colour red green white white white white white white white white white white<br />
50 <strong>Fibre</strong> <strong>optic</strong> <strong>cables</strong> 51<br />
Aerial <strong>cables</strong>
<strong>Fibre</strong> <strong>optic</strong> <strong>cables</strong><br />
Underwater cable<br />
Type<br />
FYOVMPPMW<br />
Diameter<br />
mm<br />
Weight in air/<br />
in water<br />
kg/km<br />
Pulling force during<br />
installation/final<br />
installation kN<br />
Minimum bending<br />
radius under<br />
installation tension/<br />
without tension mm<br />
Maximum<br />
water depth<br />
m<br />
12xSML 30 kN 18.5 885/615 32/24 500/400 1500<br />
2x12xSML 30 kN 18.5 885/615 32/24 500/400 1500<br />
4x12xSML 30 kN 18.5 885/615 32/24 500/400 1500<br />
8x12xSML 30 kN 19.5 1015/715 32/24 500/400 1500<br />
12xSML 40 kN 20.0 1130/815 42/32 550/450 1500<br />
2x12xSML 40 kN 20.0 1130/815 42/32 550/450 1500<br />
4x12xSML 40 kN 20.0 1130/815 42/32 550/450 1500<br />
8x12xSML 40 kN 21.5 1240/875 44/33 550/450 1500<br />
Colours of the fibres<br />
<strong>Fibre</strong> 1 2 3 4 5 6 7 8 9 10 11 12<br />
Colour blue orange green brown grey white red black yellow violet pink turquoise<br />
Colours of the binding yarns<br />
Type FYOVMPPMW<br />
Yarn 1 2 3 4 5 6 7 8<br />
Colour blue orange green brown grey white red black<br />
Application Heavily armoured underwater cable for sea, river<br />
and lake installations. <strong>Fibre</strong>s hermetically sealed<br />
inside laser welded stainless steel tube. Also for<br />
underground installation in severe conditions, for<br />
example in permafrost soil.<br />
Construction Optical fibre: Coloured <strong>optic</strong>al single-mode fibre<br />
(ITU-T G.652.D)<br />
Secondary coating: Laser welded hermetical<br />
stainless steel tube, filled with non toxic and<br />
dermatological safe compound.<br />
Inner sheath: Black homogeneous weather<br />
resistant polyethylene sheath<br />
Armour: Two layers of galvanized steel wires, over<br />
the wires a layer of bitumen.<br />
Outer sheath: Black homogeneous weather<br />
resistant polyethylene sheath<br />
Properties Temperature range<br />
Transport, storage, operation -45 ... +70 °C<br />
Installation -15 ... +60 °C<br />
Crush strength 10 000 N/100 mm<br />
52 <strong>Fibre</strong> <strong>optic</strong> <strong>cables</strong> 53<br />
Underwater <strong>cables</strong>
<strong>Fibre</strong> <strong>optic</strong> <strong>cables</strong><br />
Characteristics of <strong>optic</strong>al fibres<br />
Single -mode <strong>optic</strong>al fibres<br />
<strong>Draka</strong>’s name ESMF BendBright XS<br />
Designation SM BBXS<br />
Description Low water peak Low macrobending sensitive,<br />
low water peak<br />
Standard (ITU-T) G.652.D G.652.D, G.657.A ja G.657.B<br />
Category in EN 50173 OS2 OS2<br />
Mode field diameter 1310 nm 9.0 ± 0.4 µm 8.9 ± 0.4 µm<br />
Mode field diameter 1550 nm 10.1 ± 0.5 µm 9.9 ± 0.5 µm<br />
Cladding diameter 125 ± 0.7 µm 125 ± 0.7 µm<br />
Attenuation coefficient (maximum value for cabled fibre)<br />
1310 nm 0.35 - 0.40 dB/km 0.35 - 0.40 dB/km<br />
1383 nm (after hydrogen aging) 0.35 - 0.40 dB/km 0.35 - 0.40 dB/km<br />
1550 nm 0.22 - 0.25 dB/km 0.22 - 0.25 dB/km<br />
1625 nm 0.23 - 0.30 dB/km 0.23 - 0.30 dB/km<br />
Cut-off wavelength (cabled fibre; λcc) ≤ 1260 nm ≤ 1260 nm<br />
- for interconnection <strong>cables</strong> (fibre; λc) ≤ 1250 nm ≤ 1250 nm<br />
Chromatic dispersion<br />
- zero-dispersion wavelength 1300 - 1322 nm 1300 - 1322 nm<br />
- dispersion coefficient 1288 nm - 1339 nm ≤ 3.5 ps/(nm x km) ≤ 3.5 ps/(nm x km)<br />
- dispersion coefficient 1550 nm ≤ 18 ps/(nm x km) ≤ 18 ps/(nm x km)<br />
PMD link design value (cabled fibre) ≤ 0.2 ps/√km ≤ 0.2 ps/√km<br />
Proof stress level 1.0 % 1,0 %<br />
Effective group index @1550 nm 1.468 1.468<br />
Multimode <strong>optic</strong>al fibres<br />
Designation GK OM1 GI OM2 GI OM3<br />
Category in EN 50173 OM1 OM2 OM3<br />
Core diameter 62.5 ± 3 µm 50 ± 3 µm 50 ± 3 µm<br />
Cladding diameter 125 ± 2 µm 125 ± 2 µm 125 ± 2 µm<br />
Attenuation coefficient<br />
850 nm ≤ 3.5 dB/km ≤ 2.7 dB/km ≤ 3.5 dB/km<br />
1300 nm ≤ 1.0 dB/km ≤ 0.8 dB/km ≤ 1.0 dB/km<br />
Bandwidth<br />
850 nm (led-transmitter) ≥ 200 MHz x km ≥ 500 MHz x km ≥ 1500 MHz x km<br />
850 nm (laser-transmitter) - - ≥ 2000 MHz x km<br />
1300 nm (led-transmitter) ≥ 500 MHz x km ≥ 500 MHz x km ≥ 500 MHz x km<br />
Proof stress level 1.0 % 1.0 % 1.0 %<br />
54 <strong>Fibre</strong> <strong>optic</strong> <strong>cables</strong> 55<br />
Further details
Colour code for<br />
fibre <strong>optic</strong> <strong>cables</strong><br />
(Based on national standard SFS 5648)<br />
SPIRAL SPACE ® -CONSTRUCTION<br />
<strong>Fibre</strong><br />
number<br />
Bundle of<br />
two fibres<br />
Bundle of<br />
four fibres<br />
Bundle of<br />
six fibres<br />
1 blue blue blue<br />
2 red white white<br />
3 yellow yellow<br />
4 red green<br />
5 grey<br />
6 red<br />
Number<br />
of fibres<br />
Structure Colours of binding yarns<br />
2 1 x 2 -<br />
4 1 x 4 -<br />
6 1 x 6 -<br />
8 2 x 4 blue, red<br />
12 2 x 6 blue, red<br />
18 3 x 6 blue, white, red<br />
24 4 x 6 blue, white, yellow, red<br />
36 6 x 6 blue, white, yellow, green, grey, red<br />
48 2 x 4 x 6<br />
blue (blue, white, yellow, red)<br />
red (blue, white, yellow, red)<br />
60 2 x 5 x 6<br />
blue (blue, white, yellow, green, red)<br />
red (blue, white, yellow, green, red)<br />
blue (blue, white, yellow, red)<br />
72 3 x 4 x 6 white (blue, white, yellow, red)<br />
red (blue, white, yellow, red)<br />
blue (blue, white, yellow, red)<br />
96 4 x 4 x 6<br />
white (blue, white, yellow, red)<br />
yellow (blue, white, yellow, red)<br />
red (blue, white, yellow, red)<br />
STRANDED LOOSE TUBE CORE<br />
Colours of fibres and binding yarns<br />
Number<br />
of fibres<br />
Structure Number of<br />
bundles<br />
2 1 x 2 1 blue, red<br />
Colours of the fibres<br />
4 1 x 4 1 blue, white, yellow, red<br />
6 1 x 6 1<br />
blue, white, yellow,<br />
green, grey, red<br />
blue, white, yellow,<br />
12 2 x 6 2 green, grey, red<br />
(fibres in two bundles, colours of<br />
binding yarns: blue and red)<br />
Colours of the tubes<br />
Colours of<br />
tubes<br />
Tube number<br />
blue first<br />
white 2. 6. 10. 14.<br />
yellow 3. 7. 11. 15.<br />
green 4. 8. 12.<br />
grey 5. 9. 13.<br />
red last<br />
If the cable contains more than one type of fibres, the same<br />
colour scheme is applied so, that single-mode and multimode<br />
fibres are in the following order: SM, SM(G655), GI, GK<br />
Example:<br />
FYOVD2PMU-Y 2x4xSML+2x4xGKL<br />
fibre bundle type of fibre<br />
1 (blue) SML<br />
2 (white) SML<br />
3 (yellow) GKL<br />
4 (red) GKL<br />
56 <strong>Fibre</strong> <strong>optic</strong> <strong>cables</strong> 57<br />
Further details
Finnish type designation<br />
for <strong>optic</strong>al fibre <strong>cables</strong><br />
Type designation example:<br />
Cable design<br />
<strong>Fibre</strong> count and grouping<br />
<strong>Fibre</strong>s and coatings<br />
FYOVD2PMU 4 x 6 x SML<br />
Cable design <strong>Fibre</strong>s<br />
First letter:<br />
F = <strong>optic</strong>al fibre cable<br />
Second letter:<br />
Y = central tube design (e.g. SPIRAL SPACE ® )<br />
Z = stranded loose tube design<br />
T = tight buffer design<br />
X = slotted core design<br />
Next letters:<br />
B = laminated O = filling compound<br />
C = copper P = steel wire<br />
D = corrugated R = non-metallic strength element<br />
H = aluminium tape<br />
J = jute V = steel tape<br />
K = messenger wire S = indoor<br />
L = lead U = outdoor<br />
M = plastic W = underwater<br />
-Y = cable contains more than one type of fibre<br />
-SD = semi-dry construction<br />
E.g. FYOVD2PMU<br />
(<strong>optic</strong>al fibre cable, central tube, filled, corrugated steel tape,<br />
2 steel wires, plastic sheath, outdoor)<br />
<strong>Fibre</strong> count and grouping:<br />
Numbers after cable design indicate number of fibre units<br />
(tubes or groups) and number of fibres in the unit.<br />
Alternatively only the total number of fibres can be indicated.<br />
E.g. 4x6 (four units of six fibres)<br />
<strong>Fibre</strong>s and fibre coatings:<br />
First two characters in fibre designation indicates fibre type,<br />
the third character indicates the outer diameter of fibre coating,<br />
followed by reference to standard:<br />
SM G.652.B = Single-mode fibre (10/125 mm)<br />
ITU-T (G.652.B)<br />
SM G.652.D = Y= Single-mode fibre (10/125 mm)<br />
ITU-T (G.652.D)<br />
SM BBXS = Single-mode fibre (10/125 mm)<br />
ITU-T (G.652.D, G.657.A, G.657.B),<br />
Bend-insensitive BendBright XS fibre<br />
Gl OM2 = = Multimode fibre (50/125 mm)<br />
ITU-T (G.651)<br />
Gl OM3 = Multimode fibre (50/125 mm) (OM3)<br />
GK OM1 = Multimode fibre (62.5/125 mm) (OM1)<br />
L = 250 mm T = 900 mm<br />
R = <strong>Fibre</strong> ribbon<br />
E.g SML G652.D<br />
(Single-mode fibre ITU-T G.652.D, coating diameter 250 mm)<br />
58 <strong>Fibre</strong> <strong>optic</strong> <strong>cables</strong> 59<br />
Further details
The maximum cable lengths on the K drums (m)<br />
Drum type K6 K7 K8 K9 K10 K11 K12 K14<br />
Barrel diameter (mm) 250 325 375 425 500 575 675 800<br />
Flange diameter (mm) 600 700 800 900 1000 1100 1200 1400<br />
Net winding width (mm) 400 500 500 550 600 650 850 850<br />
Free space (mm) 30 30 30 30 30 40 40 40<br />
Carrying capacity (kg) 350 500 590 730 980 980 980 980<br />
Centre hole (mm) 75 75 75 75 106 106 106 106<br />
Select cable drum so that the barrel diameter is at least<br />
40 times the cable diameter.<br />
Cable diameter mm K6 K7 K8 K9 K10 K11 K12 K14<br />
5 2878 4674 6276 8926 11943 14286 21031<br />
6 1960 3260 4341 6113 8097 10005 14701 20152<br />
7 1396 2350 3230 4462 5935 7096 10511 14894<br />
8 1114 1765 2361 3337 4554 5434 8011 11253<br />
9 871 1404 1917 2785 3563 4294 6314 8698<br />
10 686 1119 1569 2159 2985 3571 5257 7359<br />
11 577 948 1246 1761 2442 2947 4330 5858<br />
12 490 805 1072 1511 2024 2415 3526 4858<br />
13 407 689 930 1227 1637 2125 3110 4329<br />
14 343 579 796 1065 1405 1701 2502 3569<br />
15 283 492 690 911 1249 1484 2179 3155<br />
16 278 411 590 790 1069 1279 1911 2813<br />
17 223 391 496 758 928 1235 1829 2485<br />
18 217 318 470 645 890 1073 1578 2174<br />
19 176 311 401 540 759 921 1344 1881<br />
20 171 255 392 530 746 879 1299 1818<br />
21 134 238 313 451 624 739 1112 1586<br />
22 129 231 304 440 610 724 1068 1368<br />
23 124 183 247 410 519 619 897 1310<br />
24 118 176 238 341 506 603 881 1143<br />
25 179 241 345 422 506 747 1121<br />
26 172 232 280 409 491 710 1065<br />
27 130 182 270 395 477 694 914<br />
28 124 174 259 321 389 574 892<br />
29 125 175 248 309 376 559 752<br />
30 119 167 205 312 362 544 731<br />
31 120 133 195 299 348 529 711<br />
32 85 126 197 234 289 424 690<br />
33 127 187 236 276 411 566<br />
34 119 189 225 278 414 570<br />
35 120 141 227 266 400 551<br />
36 113 142 215 268 386 532<br />
37 85 134 172 255 371 512<br />
38 135 162 204 298 426<br />
39 136 163 193 286 409<br />
40 127 164 194 288 411<br />
41 128 155 183 276 394<br />
42 96 156 184 278 396<br />
43 90 146 186 265 378<br />
44 147 174 267 304<br />
45 111 132 193 289<br />
46 111 133 194 291<br />
47 103 124 195 292<br />
48 104 125 185 277<br />
49 104 125 186 279<br />
60 <strong>Fibre</strong> <strong>optic</strong> <strong>cables</strong> 61<br />
Further details
The maximum cable lengths on the K drums (m)<br />
Drum type K16 K18 K20 K21 K22 K24 K26 K28<br />
Barrel diameter (mm) 950 1100 1300 1300 1400 1400 1500 1500<br />
Flange diameter (mm) 1600 1800 2000 2100 2200 2400 2600 2800<br />
Net winding width (mm) 850 850 1000 1000 1000 1000 1200 1350<br />
Free space (mm) 40 40 50 50 50 50 60 70<br />
Carrying capacity (kg) 2300 3000 3000 3500 4000 4500 6800 8800<br />
Centre hole (mm) 106 132 132 132 132 132 132 132<br />
Select cable drum so that the barrel diameter is at least<br />
40 times the cable diameter.<br />
Cable diameter mm K16 K18 K20 K21 K22 K24 K26 K28<br />
5<br />
6<br />
7 18702<br />
8 14336 17766<br />
9 11251 14116 18377<br />
10 9196 11672 15079 18142 19242<br />
11 7408 9536 12191 14383 15259 20809<br />
12 6201 7696 10430 12461 13218 17790<br />
13 5244 6570 8780 10168 10789 14953 21184<br />
14 4636 5838 7466 9200 9758 13190 18599<br />
15 4128 4926 6635 7844 8321 11507 15924 22240<br />
16 3458 4441 5567 6691 7100 10078 13995 19722<br />
17 3071 3975 4922 5976 6340 8726 12167 17534<br />
18 2702 3529 4390 5390 5718 7991 11118 15652<br />
19 2560 3105 3883 4828 5122 6902 9772 13851<br />
20 2272 2770 3769 4379 4646 6358 8957 12696<br />
21 1997 2452 3295 3865 4101 5708 8167 11221<br />
22 1739 2353 2914 3456 3668 5202 7404 10323<br />
23 1663 2056 2808 3333 3535 4714 6802 9452<br />
24 1468 1831 2454 2950 3130 4247 6220 8765<br />
25 1439 1794 2412 2902 3078 4184 5658 8096<br />
26 1216 1532 2082 2542 2697 3738 5119 7303<br />
27 1188 1496 2041 2265 2404 3407 4941 6818<br />
28 1159 1459 1737 2158 2290 3251 4432 6212<br />
29 992 1266 1698 2112 2240 2940 4047 6011<br />
30 965 1231 1658 1858 1972 2876 3981 5560<br />
31 938 1196 1428 1814 1925 2581 3518 5004<br />
32 788 1020 1391 1577 1675 2519 3452 4930<br />
33 762 987 1354 1536 1630 2240 3106 4402<br />
34 767 993 1145 1494 1585 2181 3041 4328<br />
35 741 832 1111 1451 1539 1921 2975 3934<br />
36 607 802 1077 1239 1316 1864 2652 3860<br />
37 584 771 1083 1246 1322 1876 2588 3486<br />
38 588 776 895 1207 1280 1633 2285 3414<br />
39 564 634 864 1012 1075 1580 2225 3059<br />
40 568 637 868 1017 1080 1589 2239 2989<br />
41 450 610 837 981 1042 1364 1955 2919<br />
42 453 613 806 945 1003 1315 1898 2673<br />
43 432 585 675 950 1008 1322 1840 2606<br />
44 434 588 648 777 826 1271 1851 2538<br />
45 413 464 651 781 829 1278 1592 2307<br />
46 415 466 623 749 795 1077 1600 2243<br />
47 418 468 626 752 798 1082 1547 2178<br />
48 317 444 598 719 763 1035 1555 2191<br />
49 319 446 600 722 766 1041 1500 1902<br />
62 <strong>Fibre</strong> <strong>optic</strong> <strong>cables</strong> 63<br />
Further details
Cable drum<br />
dimensions and weights<br />
Drum type<br />
SSTL code<br />
Dimensions mm Drum<br />
A B C D E<br />
weight<br />
kg<br />
K5 9999705 500 368 200 300 75 9<br />
K6 9999706 600 468 250 400 75 12<br />
K7 9999707 700 580 325 500 75 20<br />
K8 9999708 800 580 375 500 75 25<br />
K9 9999709 900 630 425 550 75 34<br />
K10 9999710 1000 712 500 600 75 54<br />
K11 9999711 1100 762 575 650 106 55<br />
K12 9999712 1200 982 675 850 106 90<br />
K14 9999714 1400 982 800 850 106 115<br />
K16 9999716 1600 1018 950 850 106 195<br />
K18 9999718 1800 1075 1100 850 132 230<br />
K20 9999720 2000 1190 1300 1000 132 340<br />
K21 9999721 2100 1190 1300 1000 132 360<br />
K22 9999722 2200 1190 1400 1000 132 410<br />
K24 9999724 2400 1205 1400 1000 132 450<br />
K26 9999726 2600 1448 1500 1200 132 910<br />
K28 9999728 2800 1650 1500 1350 132 1190<br />
K30 9999730 3000 1800 1500 1500 132 1510<br />
5C 9999405 500 500 250 400 55 10<br />
6C 9999406 600 500 250 400 55 16<br />
7E 9999407 700 610 325 500 55 20<br />
8E 9999408 800 610 375 500 55 26<br />
9F 9999409 900 660 425 550 82 40<br />
9FV 9999410 900 675 425 550 82 50<br />
11G 9999459 1100 725 500 600 82 70<br />
11GV 9999460 1100 755 500 600 82 85<br />
13G 9999463 1300 760 600 600 82 105<br />
15G 9999465 1500 760 700 600 82 150<br />
16L 9999416 1600 970 800 800 82 185<br />
18M 9999418 1800 1025 1100 850 82 260<br />
18P 9999419 1800 1135 1100 960 82 265<br />
20P 9999421 2000 1155 1100 960 82 350<br />
21P 9999424 2100 1155 1100 960 82 390<br />
22P 9999422 2200 1155 1200 960 82 445<br />
26U 9999426 2600 1455 1500 1200 123 805<br />
28W 9999428 2800 1610 1500 1300 123 1050<br />
30Y 9999430 3000 1810 2200 1500 123 1275<br />
32Z 9999432 3200 1970 2400 1600 132 2000<br />
OPG16 9999016 1600 1125 800 965 82 259<br />
OPG18 9999018 1800 1125 900 965 82 314<br />
OPG20 9999020 2000 1125 900 945 82 421<br />
details<br />
64 <strong>Fibre</strong> <strong>optic</strong> <strong>cables</strong> 65 Further
Kimmeltie 1, FI-02110 ESPOO, Finland<br />
P.O. BOX 419, FI-00101 HELSINKI, Finland<br />
Telephone +358 10 5661, Fax +358 10 566 3394<br />
www.draka.fi<br />
66 02/2009