Experience In Motion<br />

<strong>Critical</strong> <strong>Service</strong> <strong>Valves</strong><br />

Edward <strong>Valves</strong> and Anchor/Darling <strong>Valves</strong>


Quality valves for critical service<br />

For 100 years, <strong>Flowserve</strong> Edward <strong>Valves</strong> and Anchor/<br />

Darling <strong>Valves</strong> have manufactured high-quality gate,<br />

globe and check valves used in critical industry service<br />

around the world.<br />

Edward and Anchor/Darling <strong>Valves</strong> have an ISO 9001 Nstamped<br />

certified manufacturing facility in North Carolina,<br />

supporting a worldwide network of end users, OEMs and<br />

distributors with access to the world’s largest capability<br />

for the manufacturing of forged and cast steel valves.<br />

Widely used in the nuclear, fossil, petroleum, petrochemical<br />

and process industries, Edward and<br />

Anchor/Darling <strong>Valves</strong> valves are<br />

built to provide a lifetime of reliable<br />

service—there is no equal.<br />

Edward <strong>Valves</strong> and Anchor/Darling <strong>Valves</strong><br />

are part of <strong>Flowserve</strong> Flow Control, the<br />

world’s foremost specialty valve manufacturing<br />

organization.


Certified quality<br />

<strong>Flowserve</strong> Edward and Anchor/Darling <strong>Valves</strong> factories are<br />

registered under the most stringent ISO 9001 quality<br />

standards. Edward and Anchor/Darling <strong>Valves</strong> carry the<br />

ASME Section III “N” stamp certification for the design and<br />

manufacture of nuclear grade valves, and meets specifications<br />

including ASME B16.34. Edward and Anchor/Darling<br />

valves are designed for a 40 year service life, and allow easy<br />

maintenance and service. The high quality pays off over the<br />

life of the valve with total cost of ownership.<br />

flowserve.com


Small-Bore Forged and Cast<br />

Gate, Globe and Check <strong>Valves</strong><br />

PressurCombo<br />

Size: 1/2"–4" (15 mm–100 mm)<br />

Pressure Class: 1690–4500<br />

Ends: Flanged, Butt & Socket Weld<br />

Continuous<br />

Blowdown<br />

Size: 1/2"–4" (15 mm–100 mm)<br />

Pressure Class: 1925<br />

Ends: Butt and Socket Weld<br />

Univalve<br />

Size: 1/2"–4" (15 mm–100 mm)<br />

Stop, Stop-Check, Check<br />

Pressure Class: 1690–4500<br />

Ends: Flanged, Threaded, Butt & Socket Weld<br />

Bolted Bonnet Globe<br />

Size: 1/4"–2" (8 mm–50 mm)<br />

Stop, Stop-Check, Check<br />

Pressure Class: 600 & 800<br />

Ends: Flanged, Threaded, Socket Weld


WLC<br />

Size: 1"–2"<br />

Inline Check<br />

Presure Class: 150, 300, 600, 900, 1500<br />

Ends: Butt Weld<br />

Note: Nuclear service only.<br />

1878 Series<br />

Size: 1/2"–2"<br />

Globe, Instrument, Piston Check, Swing<br />

Check<br />

Presure Class: 1878<br />

Ends: Threaded, Socket Weld<br />

1888 Series<br />

Size: 3/4"–2"<br />

Gate<br />

Presure Class: 1888<br />

Ends: Threaded, Socket Weld<br />

800 Series<br />

Size: 1/2"–2"<br />

Globe, Gate<br />

Presure Class: 800<br />

Ends: Threaded, Socket Weld<br />

flowserve.com


Small-Bore Forged and Cast<br />

Gate, Globe and Check <strong>Valves</strong><br />

Angle – Cast<br />

and Forged Steel<br />

Size: 1/2"–24" (15 mm–600 mm)<br />

Stop, Non-Return, Check<br />

Pressure Class: 300–2500<br />

Ends: Threaded, Flanged, Butt & Socket Weld<br />

Ball Check<br />

Size: 1/4"–2" (8 mm–50 mm)<br />

Pressure Class: 800, Series 1500<br />

Ends: Threaded or Socket Weld<br />

Ball <strong>Valves</strong><br />

Size: 3/4"–2"<br />

Standard Port, Full Port<br />

Presure Class: 150–300<br />

Ends: Threaded, Socket Weld<br />

GLC<br />

Size: 1–21/2"<br />

Inline Check<br />

Presure Class: 150, 300, 600, 900, 1500<br />

Ends: Flanged<br />

Note: Nuclear service only.


Large-Bore Forged and Cast<br />

Gate, Globe and Check <strong>Valves</strong><br />

Flex-Wedge Gate<br />

Size: 21/2"–24" (65 mm–600 mm)<br />

Bolted Bonnet<br />

Pressure Class: 150–2500<br />

Ends: Butt Weld<br />

T-Globe<br />

Size: 21/2"–24" (65 mm–600 mm)<br />

Bolted Bonnet<br />

Pressure Class: 150–2500<br />

Ends: Butt Weld<br />

Double Disc Gate<br />

Size: 21/2"–24" (65 mm–600 mm)<br />

Bolted Bonnet, Pressure Seal<br />

Pressure Class: 150–2500<br />

Ends: Flanged, Butt Weld<br />

Swing Check<br />

Size: 21/2"–24" (65 mm–600 mm)<br />

Bolted Bonnet, Pressure Seal<br />

Pressure Class: 150–2500<br />

Ends: Flanged, Butt Weld<br />

flowserve.com


Large-Bore Forged and Cast<br />

Gate, Globe and Check <strong>Valves</strong><br />

Three-Way<br />

Diverting Globe<br />

Size: 21/2"–24" (65 mm–600 mm)<br />

Pressure Seal, Bolted Bonnet<br />

Pressure Class: 150–2500<br />

Ends: Butt Weld, Flanged<br />

Flite-Flow<br />

Size: 3"–32" (80 mm–800 mm)<br />

Stop, Non-Return, Check<br />

Pressure Class: 300–4500<br />

Ends: Butt Weld<br />

Equiwedge Gate<br />

Size: 21/2"–28" (65 mm–700 mm)<br />

Pressure Class: 600–2500<br />

Ends: Flanged, Butt Weld<br />

Globe<br />

Size: 21/2"–24" (65 mm–600 mm)<br />

Stop, Non-Return, Check<br />

Pressure Class: 300–2500<br />

Ends: Flanged, Butt Weld


Nuclear –<br />

Cast Steel / MSIVs<br />

Size: 21/2"–32" (65 mm–800 mm)<br />

Pressure Class: 600–1500<br />

Ends: Flanged, Butt Weld<br />

Y-Globe<br />

Size: 21/2"–24" (65 mm–600 mm)<br />

Bolted Bonnet<br />

Pressure Class: 150–2500<br />

Ends: Butt Weld<br />

Pressure Seal Globe<br />

Size: 21/2"–24" (65 mm–600 mm)<br />

Pressure Class: 150–2500<br />

Ends: Butt Weld<br />

Tilting Disk Check<br />

Size: 21/2"–24" (65 mm–600 mm)<br />

Pressure Class: 600–4500<br />

Ends: Butt Weld<br />

Elbow Down<br />

Size: 10"–18" (250 mm–450 mm)<br />

Pressure Class: 1500 & 2500<br />

Ends: Butt Weld<br />

flowserve.com


10<br />

Actuators and Accessories<br />

Actuators<br />

<strong>Flowserve</strong> supplies a full range of electric,<br />

pneumatic, hydraulic, manual gear and<br />

stored energy gas/hydraulic actuators.<br />

<strong>Flowserve</strong> engineers are available to<br />

help you correctly size and specify<br />

your actuator requirements.<br />

Accessories<br />

A complete range of accessories and options<br />

are available for Edward and Anchor/Darling<br />

forged and cast steel valves, including:<br />

automatic center cavity equalizing valves,<br />

floor stands, chain wheels, valve extensions,<br />

drains and vents, equalizers, locking devices<br />

and more.


<strong>Flowserve</strong> Flow Control<br />

<strong>Flowserve</strong> Flow Control is the foremost<br />

specialist valve and controls manufacturing<br />

organization in the world. <strong>Flowserve</strong> supplies<br />

contractors, OEMs, distributors and end users<br />

with a product range of unparalleled breadth to<br />

meet modern industry’s flow control needs in<br />

markets including:<br />

• Chemical<br />

• Power Generation/Nuclear <strong>Service</strong><br />

• Oil & Gas<br />

• Petrochemical & Refining<br />

• Pulp & Paper<br />

• Process Industries, including Food and<br />

Pharmaceuticals<br />

• Additional markets including HVAC, Mining and<br />

Water<br />

• Special applications, including Cryogenic, Acid/<br />

Sour <strong>Service</strong>, Erosive and Corrosive <strong>Service</strong>,<br />

and Zero Emission<br />

flowserve.com<br />

11


FCD ADABR0001-00 Printed in USA.<br />

To find your local <strong>Flowserve</strong> representative:<br />

For more information about <strong>Flowserve</strong> <strong>Corporation</strong>, visit<br />

www.flowserve.com or call USA 1 800 225 6989<br />

<strong>Flowserve</strong> <strong>Corporation</strong> has established industry leadership in the design and manufacture of its products. When properly selected, this <strong>Flowserve</strong> product is designed to perform its<br />

intended function safely during its useful life. However, the purchaser or user of <strong>Flowserve</strong> products should be aware that <strong>Flowserve</strong> products might be used in numerous applications<br />

under a wide variety of industrial service conditions. Although <strong>Flowserve</strong> can (and often does) provide general guidelines, it cannot provide specific data and warnings for all possible<br />

applications. The purchaser/user must therefore assume the ultimate responsibility for the proper sizing and selection, installation, operation, and maintenance of <strong>Flowserve</strong> products.<br />

The purchaser/user should read and understand the Installation Operation Maintenance (IOM) instructions included with the product, and train its employees and contractors in the safe<br />

use of <strong>Flowserve</strong> products in connection with the specific application.<br />

While the information and specifications contained in this literature are believed to be accurate, they are supplied for informative purposes only and should not be considered certified or<br />

as a guarantee of satisfactory results by reliance thereon. Nothing contained herein is to be construed as a warranty or guarantee, express or implied, regarding any matter with respect<br />

to this product. Because <strong>Flowserve</strong> is continually improving and upgrading its product design, the specifications, dimensions and information contained herein are subject to change<br />

without notice. Should any question arise concerning these provisions, the purchaser/user should contact <strong>Flowserve</strong> <strong>Corporation</strong> at any one of its worldwide operations or offices.<br />

© 2005 <strong>Flowserve</strong> <strong>Corporation</strong>, Irving, Texas, USA. <strong>Flowserve</strong> is a registered trademark of <strong>Flowserve</strong> <strong>Corporation</strong>.<br />

flowserve.com<br />

United States<br />

<strong>Flowserve</strong> Corp.<br />

<strong>Flowserve</strong> Flow Control<br />

1900 South Saunders Street<br />

Raleigh, NC 27603<br />

Telephone: 1 919 832 0525<br />

Fax: 1 919 831 3369

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!