I F<br />

K f<br />

Z thJC<br />

40<br />

A<br />

35<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

2.0<br />

1.5<br />

1.0<br />

0.5<br />

0.0<br />

0 40 80 <strong>12</strong>0 °C 160<br />

10<br />

K/W<br />

1<br />

0.1<br />

0.01<br />

T =150°C<br />

VJ<br />

T =100°C<br />

VJ<br />

T = 25°C<br />

VJ<br />

T VJ<br />

0.001<br />

0.00001 0.0001 0.001 0.01 0.1 s 1<br />

t<br />

Fig. 7 Transient thermal resistance junction to case<br />

NOTE: Fig. 2 to Fig. 6 shows typical values<br />

Q r<br />

t rr<br />

3.0<br />

�C<br />

2.5<br />

2.0<br />

1.5<br />

1.0<br />

0.5<br />

180<br />

ns<br />

160<br />

140<br />

<strong>12</strong>0<br />

T VJ = 100°C<br />

V R = 600V<br />

I F = 30A<br />

I F = 15A<br />

I F = 7.5A<br />

T VJ = 100°C<br />

V R = 600V<br />

<strong>DSEP</strong> <strong>12</strong>-<strong>12</strong>A<br />

100<br />

0<br />

0.0<br />

0 200 400 600 A/�s 800 1000<br />

0 200 400 600 A/�s 800 1000<br />

-di /dt F<br />

diF /dt<br />

Fig. 5 Recovery time t versus -di /dt rr F Fig. 6 Peak forward voltage V and t FR fr<br />

versus di /dt F<br />

© 2000 <strong>IXYS</strong> All rights reserved 2 - 2<br />

<strong>DSEP</strong> <strong>12</strong>-<strong>12</strong>A<br />

I RM<br />

V FR<br />

50<br />

A<br />

40<br />

30<br />

20<br />

10<br />

<strong>12</strong>0<br />

V<br />

80<br />

40<br />

T VJ = 100°C<br />

V R = 600V<br />

I F = 30A<br />

I F = 15A<br />

I F = 7.5A<br />

0<br />

0.0<br />

0<br />

0 1 2 3 V 4<br />

100 A/�s 1000<br />

0 200 400 600 A/�s 800 1000<br />

VF -di /dt F -diF /dt<br />

Fig. 1 Forward current I versus V F F Fig. 2 Reverse recovery charge Qr versus -di /dt F<br />

Fig. 3 Peak reverse current IRM versus -di /dt F<br />

I RM<br />

Q r<br />

Fig. 4 Dynamic parameters Q r , I RM<br />

versus T VJ<br />

I F = 30A<br />

I F = 15A<br />

I F = 7.5A<br />

t fr<br />

T VJ = 100°C<br />

I F = 15A<br />

V FR<br />

Constants for Z thJC calculation:<br />

i R (K/W) thi t (s) i<br />

1 0.9084 0.0052<br />

2 0.3497 0.0003<br />

3 0.3419 0.0165<br />

1.2<br />