Product brochure Electronic Lamp Control - eta plus electronic GmbH

etauv

Product brochure Electronic Lamp Control - eta plus electronic GmbH

ELC ®

Electronic Lamp Control

eta plus electronic gmbh

part of the IST METZ group, Lauterstrasse 29, D-72622 Nuertingen, Germany

tel: +49 (0)7022 60 02 813; fax: +49 (0)7022 60 02 888

@: Anne.Ocallaghan@eta-uv.de www.eta-uv.de Stand: April 2010


3/7/2012

ELC ® general information

The electronic lamp control units ELC ®

are designed to power UV medium

pressure discharge lamps. In four

different series we offer fully integrated

electronic lamp control solutions for UV

lamps from 3 kW to 32 kW.

Various air and water based cooling

options offer most flexible power system

integration. The ELC ® control strategies

allow easy PLC connection as well as

smart control and servicing options.

Technology:

All ELC ® are based on a high

frequency resonant power converter to

precisely power the medium pressure

lamps. This topology combines highest

efficiency at lowest electromagnetic

interference. The fully insulated lamp

output allows perfect lamp matching as

well as short circuit and earth fault

resistant operation.

Your success:

Our customer-specific in-house lamp

development permits the optimum component

match for your UV system.

Coupled with the consistent burn-in of

each ELC ® this enables your UV system

to attain highest lamp service lifetime.

� system reliability

- smart soft ignition

- highest lamp lifetime

� efficiency

- low heat exhaust

- highest ambient temperature

- energy savings

� stepless lamp control

- dimming range 20% – 100%

- precisely controlled and

monitored lamp status

� mains compliance

- high power factor

- low harmonic distortion

- symmetric load

- no inrush current

- no start-up over-current

� safety features

- insulated lamp output

- integrated earth fault detection

- short circuit proof

ELC ® is a registered trademark of IST Metz GmbH

2


3/7/2012

ELC ® Series

ELC ® N-Series

• nominal lamp power: 3 kW to 32 kW

• analog / digital PLC control port

• highest efficiency

• protection IP 20

• air cooled

ELC ® P-Series

• nominal lamp power: 5 kW to 32 kW

• field bus (PROFIBUS) control

• highest efficiency

• protection IP 20

• air cooled

ELC ® X-Series

• nominal lamp power: 6 kW, (4kW*, 8kW*)

• field bus (PROFIBUS) control

• wide input voltage range 360V to 528 V

• lowest harmonic distortion THDi

• protection IP 66

• innovative air cooling concept

ELC ® IP-Series

• nominal lamp power: 5 kW to 10 kW

• field bus (PROFIBUS) control

• protection IP 65

• water cooled

* under development

3


3/7/2012

ELC ® N-Series

A modular ELC ® concept offering the

highest efficiency and process

stability for all applications. The

analog control port offers easy

connection to any PLC.

Type

400 V version

ELC N3HV-400-30

ELC N4HV-400-40

ELC N2x4-400-40

ELC N5HV-400-40

ELC N6-400-75

ELC N8-400-80

ELC N10-400-80

ELC NE12-400-110

ELC NE16-400-140

ELC NE22-400-220

ELC NE32-400-280

mains voltage

power factor

efficiency

harmonic current distortion

control port

safety interrupt

lamp dimming range

lamp monitoring

earth fault detection

max. distance ELC ® to lamp

protection

max. ambient temp.

cooling

dimensions

weight

approvals

Type

480 V version

ELC N3HV-480-30

ELC N2x4-480-40

ELC N2x4-480-40

ELC N5HV-480-40

ELC N6-480-75

ELC N8-480-80

ELC N10-480-80

on request

on request

on request

on request

400V or 480 V, +- 10%, 3 phase, 50 / 60 Hz

N-type: typ. 0.93. NE-type: typ. 0.88

N-type: typ. 96 %, NE-type: typ. 94% (depending on ELC type)

N-type: 33 %, NE-type: typ. 45% *

analog 0-10V, digital I/O, PLC compatible

no

20% to 100%

current, power

standard

15 to 40m (depending on ELC type)

IP20

4 kW

40 °C to 50 °c (depending on ELC type)

forced air cooling,

see table above

lamp power

3 kW

two times 4 kW

5 kW

6 kW

8 kW

10 kW

12 kW

16 kW

22 kW

32 kW

typ. 15 kg to 37 kg

lamp

voltage

300V

400V

400V

400V

750V

800V

800V

1100V

1400V

2200V

2800V

CE, EN 50 178, (UL depending on ELC type)

dimensions:

see

Appendix A

Appendix A

Appendix A

Appendix A

Appendix A

Appendix A

Appendix A

Appendix B

Appendix B

Appendix C

Appendix C

subject to technical alterations * NE type requires additional mains choke Uk = 4%

4


3/7/2012

ELC ® P-Series

Based on the N-series, the P-series

offers a smart digital field bus

control combined with highest power

density in a compact and efficient

design. The field bus control enables

in-field diagnostics, and significantly

reduces wiring

Type

400 V version

ELC P5HV-400-40

ELC P8-400-80

ELC P10-400-80

ELC PE12-400-110

ELC PE16-400-140

ELC PE22-400-220

ELC PE32-400-280

* under development

mains voltage

power factor

efficiency

harmonic current distortion THDi

control port

safety interrupt

lamp dimming range

lamp monitoring

earth fault detection

max. distance ELC ® to lamp

protection

max. ambient temp.

cooling

dimensions

weight

approvals

Type

480 V version

ELC P5HV-480-40

ELC P8-480-80

ELC P10-480-80*

on request

on request

on request

on request

lamp power

5 kW

8 kW

10 kW

12 kW

16 kW

22 kW

32 kW

400V or 480 V, +- 10%, 3 phase, 50 / 60 Hz

P-type: typ. 0.93, PE-type: typ. 0.90

P-type: typ. 96 %, PE-type: typ. 94%

P-type: 33 %, PE-type: typ. 36% *

PROFIBUS

yes

20% to 100%

voltage, current, power

standard

15 to 40m (depending on ELC type)

IP20

40 °C to 50 °C (depending on ELC type)

forced air cooling,

see table above

typ. 15 kg to 37 kg

CE, EN 50 178

lamp

voltage

400V

800V

800V

1100V

1400V

2200V

2800V

dimensions:

see

Appendix A

Appendix A

Appendix A

Appendix B

Appendix B

Appendix C

Appendix C

subject to technical alterations * PE type require additional mains choke Uk = 4%

5


3/7/2012

ELC ® X-Series

The result of intense in-house R&D

and market experience, the X-series

combines ideal mains compatibility

with a highly innovative cooling

principle for best reliability and

cabinet free installation. The field

bus allows smart control and in- field

diagnostics.

Type

ELC X4-40*

ELC X6-60

ELC X8-80*

* Under development

mains voltage

power factor

efficiency

harmonic current distortion

control port

safety interrupt

lamp dimming range

lamp monitoring

earth fault detection

max. distance to lamp

protection

Max. ambient temp.

cooling

dimensions

weight

approvals

special feature

subject to technical alterations

Lamp power

4 kW

6 kW

8 kW

wide input range 360V – 528V, 2 phase

typ. 0.98

typ. 93%

THDi < 5%

PROFIBUS

standard

16% to 100%

voltage, current, power

standard

30m

IP66

45 °C

forced air cooling, no air filter required

540 x 320 x 125 mm (w x d x h)

typ. 15 kg

Lamp voltage

400 V

600 V

800 V

CE, EN 50 178, (UL under development.)

stacking option allows cabinet-free installation of up to 12

modules in one tower

6


3/7/2012

ELC ® IP-Series

Perfectly protected water-cooled

ELC ® for harsh operating conditions.

This series is controlled via

PROFIBUS, allowing smart control

and in-field diagnostics.

Type

400 V version

ELC P5IP-400-40

ELC P8IP-400-80

ELC P10IP-400-80*

power factor

efficiency

safety interrupt

lamp monitoring

earth fault detection

max. distance ELC® to lamp

protection

max. water temperature

cooling

dimensions

weight

approvals

* on request

mains voltage

harmonic current distortion

control port

lamp dimming range

subject to technical alterations

Type

480 V version

ELC P5IP-480-40

ELC P8IP-480-80

ELC P10IP-480-80*

400V or 480 V, 3 phase , +- 10%, 50 / 60 Hz

typ. 0,93

typ. 96 %

THDi 33 %

PROFIBUS

standard

20% to 100%

voltage, current, power

standard

15 to 20m (depending on ELC type)

IP65

35 °C

water 3L / min

approx. 540 x 130 x 235 mm (h x w x d)

approx. 15 kg

CE, EN 50 178

lamp power

5 kW

8 kW

10 kW

lamp

voltage

400V

800V

800V

7


3/7/2012

Appendix A: ELC ® N3 to N10, P5 to P10

473 mm

130 mm

pin-and-socket connector

for control signals

min. 50

min. 100

min. 100

top

Lamp feeder connection

321 mm

min. 20

mains connection

Side-by-side rack mounting

(see manual for further info.)

539 mm

23 mm

80 mm

520 mm

M8 (4x)

Back mounting

(see manual for further info.)

8


3/7/2012

Appendix B: ELC ® NE12, NE16, PE12 , PE16

Lufteintritt

air entrance

Netzanschluß

line input

Lampenstecker

lampconnection

261 mm

Steckerleiste für Steuersignale

control connector

Oben

top

263,5 mm

540 mm

31 mm 200 mm

31 mm

Luftaustritt

air exhaust

min. 150

min. 150

501 mm

650 mm

9


3/7/2012

Appendix C: ELC ® NE22, NE32, PE22 , PE32

Lufteintritt

air entrance

Lufteintritt

air entrance

Netzanschluß

line input

Lampenstecker

lampconnection

261 mm

Steckerleiste für Steuersignale

Oben

top

control connector

540 mm

484 mm

31 mm 200 mm

31 mm

Luftaustritt

air exhaust

Luftaustritt

air exhaust

min. 150

min. 150

501 mm

650 mm

10