<strong>Conductix</strong>-<strong>Wampfler</strong> Cable GPM<br />

Technical data<br />

Electrical<br />

parameters<br />

Thermal<br />

parameters<br />

Mechanical<br />

parameters<br />

Chemical<br />

parameters<br />

Materials<br />

Design<br />

features<br />

rated voltage UoU = 600/1000V<br />

maximum permitted AC operating voltage UoU = 700/1200V<br />

maximum permitted DC operating voltage UoU = 900/1800V<br />

AC test voltage according to IEC 60502-1<br />

3 G 2.5 4 G 2.5 5 G 2.5 4 G 4 5 G 4 4 G 6 5 G 6<br />

current carrying capacity max [A] (1) 36 31 31 42 42 54 54<br />

voltage drop [V/A.km] (2) 14.0 14.0 14.0 8.8 8.8 5.9 5.9<br />

resistance max [Ohm/km] (3) 7.98 7.98 7.98 4.95 4.95 3.30 3.30<br />

ambient temperature<br />

flexing -25°C to +60°C<br />

fixed -30°C to +60°C<br />

maximum permitted operating temperature at conductor 80°C<br />

short-circuit temperature at conductor 200°C<br />

minimum radii <strong>for</strong> continuous flexing<br />

6 x Ø on spool<br />

4 x Ø on anti-tension drum<br />

9 x Ø on guiding device – PULLEY NOT RECOMMENDED<br />

tensile load bearing capacity according to data table<br />

combustion behaviour of low flammability according to DIN VDE 0482 part 265-2-1; IEC 60332-1<br />

resistant to ozone yes<br />

resistant to humidity yes<br />

UV-resistant yes<br />

Resistant to moisture yes<br />

oil resistant yes<br />

halogene free Yes<br />

insulation special polypropylene compound<br />

inner sheath special polyurethane compound<br />

outer sheath special polyurethane compound<br />

color black<br />

conductor flexible copper, category 5 according to DIN VDE 0295 / IEC 60228<br />

stranding<br />

conductor coding<br />

Brand <strong>Conductix</strong>-<strong>Wampfler</strong><br />

<strong>Conductix</strong>-<strong>Wampfler</strong> <strong>Cables</strong> <strong>for</strong> Basic <strong>Reeling</strong><br />

short length of lay and assembled conductors around a polypropylene rein<strong>for</strong>ced<br />

filler (4G & 5G)<br />

3G green/yellow, blue, brown<br />

4G green/yellow, brown, black, grey<br />

5G green/yellow, blue, brown, black, grey<br />

Marking CONDUCTIX-WAMPFLER GPM …G…. mm 2 0.6/1 KV ww-yyyy<br />

(1) cable laid straight on the ground at +30°C<br />

(2) cos phi = 0,8 / temperature of cores = + 90°C<br />

(3) DC resistance of a core at +20°C<br />