RMG 4 C-Last <strong>KNX</strong><br />

<strong>KNX</strong><br />

Switching actuators SYSTEMS<br />

Switching actuators C-load 4–12 channels MIX<br />

RMG 4 C-Load <strong>KNX</strong> RME 4 C-Load <strong>KNX</strong><br />

Description<br />

Common functions<br />

■ 4-way C load switching actuator MIX<br />

■ For higher lamp loads<br />

■ Up to 2 extension modules can be connected<br />

to a basic module<br />

■ Can be combined with all MIX series devices<br />

■ Free combination of switches, dimming,<br />

blinds and heating control as well as binary<br />

inputs<br />

12<br />

■ LED switching status display for each<br />

channel<br />

■ Manual switch with On/Off/Bus settings<br />

(also without bus voltage)<br />

■ Adjustable characteristics: e.g. switching,<br />

delayed switching, pulse function<br />

■ Switching functions: e.g. On/Off, pulse, On/<br />

Off delay, staircase light with warning<br />

■ Logical links: e.g. lock, AND, release, OR<br />

Product selection Technical data<br />

Type Article number<br />

RMG 4 C-Load <strong>KNX</strong> 4910206<br />

RME 4 C-Load <strong>KNX</strong> 4910207<br />

Connection example<br />

RMG 4 C-Load <strong>KNX</strong><br />

3 4 5 6 7 8 9 10<br />

C1 C2 C3 C4<br />

L N<br />

<strong>KNX</strong><br />

N<br />

L<br />

L<br />

httpAdditional technical data at:<br />

www.theben.de/product/ Article number<br />

RMG 4 C-Load <strong>KNX</strong><br />

■ Basic module MIX<br />

■ Can be upgraded to maximum of 12<br />

channels<br />

RME 4 C-Load <strong>KNX</strong><br />

■ Extension module MIX<br />

■ For upgrading to maximum of 12 channels<br />

Operating voltage <strong>KNX</strong> Bus voltage, (< 10 mA)<br />

RMG 4 C-Load <strong>KNX</strong> RME 4 C-Load <strong>KNX</strong><br />

Operating voltage 230 V AC<br />

Frequency 50 Hz<br />

Stand-by consumption 2 W<br />

Width 4 modules<br />

Type of contact<br />

NO contact, 16 A (at 250 V AC, cos φ = 1),<br />

16 A (at 250 V AC, cos φ = 0.6)<br />

Ambient temperature –5 °C…+45 °C<br />

Protection rating IP 20<br />

Protection class II in accordance with EN 60 730-1<br />

RME 4 C-Load <strong>KNX</strong><br />

3 4 5 6 7 8 9 10<br />

C1<br />

L N<br />

C2 C3 C4<br />

N LL