GUIDELINES FOR FACTORY-INSTALLED FITTINGS<br />

Before ordering a FABCO Tank with factory installed welded fi ttings, consider:<br />

space constraints, tank elevation, whether indoor or outdoor use, location,<br />

building codes, safety regulations, piping and all other equipment that will be<br />

attached to the tank.<br />

1. When a fi tting is welded onto the side of a tank that is not elevated, complete<br />

drainage is impossible. This applies to fl anges, spigots, and bulkheads.<br />

Specify that the fi tting’s centreline must be as close as possible to the bottom<br />

of the tank. For maximum drainage, see descriptions below.<br />

2. Fittings welded to tank bottoms will drain to within 1/8 in. of the bottom<br />

(bulkheads vary by size). The tank’s foundation must have a cut-out or channel<br />

for the fi tting and its piping.<br />

3. When tanks are elevated, welded fi ttings can be installed low on the tank<br />

wall, providing drainage to within 1/4 in. of the bottom (bulkheads vary with<br />

size). The bulkhead must not interfere with the support.<br />

4. Welded fi ttings are not fl ush with tank bottom. This prevents<br />

complete drainage.<br />

How To Specify Fittings And Their Locations<br />

When you order factory-installed fi ttings on your FABCO<br />

Tanks, you must provide detailed installation information.<br />

You must provide <strong>Fabco</strong> with:<br />

1. The catalogue number for each fi tting.<br />

2. The catalogue number for each tank.<br />

3. Two complete views of each tank with its fi tting(s). Large<br />

clear, freehand drawings - as shown - are acceptable.<br />

NOTE: On cylindrical tanks, fi ttings will be installed 6 inches to<br />

the left of the calibration marks, unless otherwise specifi ed.<br />

On conical-bottom tanks, fi ttings will be center-bottom drains<br />

installed at the cone tip, unless otherwise specifi ed.<br />

SPECIFY ALL “X” DIMENSIONS IN INCHES OR DEGREES<br />

7-13<br />