DSA Report 6121 Lundy's Lane - Niagara Falls, Ontario, Canada

niagarafalls.ca

DSA Report 6121 Lundy's Lane - Niagara Falls, Ontario, Canada

Designated Substances and Select

Hazardous Materials Assessment

within

6121 Lundy’s Lane

Niagara Falls, Ontario

L2G 1T4

provided to

City of Niagara Falls

4310 Queen Street

Niagara Falls, Ontario

L2E 6X5

July 2012

OESN Project #: 00015.063


Designated Substances and Select Hazardous Materials Assessment 6121 Lundy’s Lane, Niagara Falls, Ontario

Executive Summary

Ontario Environmental & Safety Network Ltd. (herein referred to as OESN) was retained by the City of Niagara Falls

(herein referred to as the City) to assess construction materials, building mechanical systems, finished products,

equipment, appliances, and furnishings within the building located at 6121 Lundy’s Lane, Niagara Falls, Ontario. The

purpose of the assessment was to identify for the presence of designated substances and select hazardous

materials, as required in Section 30 of the Ontario Occupational Health and Safety Act and Regulations for

Construction Projects, which states before beginning a project, the owner shall determine whether any designated

substances are present at the project site and shall prepare a list of all designated substances present at the site.

Summarized below are the materials identified at the project site which were analytically determined to contain

designated substances:

Designated

Substance

Description

Asbestos 1. Linoleum 2. Texture Coat – Ceiling (Stippled)

3. Paper Backing (Behind Electrical Panel) 4. Coating Under Stainless Steel Sink*

5. Cement Shingles*

Lead 1. White Paint 2. Cream Paint

3. Cinnamon Paint 4. Taupe Paint

Mercury 1. White Paint 2. Cinnamon Paint

3. Taupe Paint

� One (1) mercury-containing thermostat was identified on the main floor

Silica � It is assumed that silica is present within the concrete, concrete block, ceramic tile, brick and

mortar materials at the project site

*Material was not sampled, but it is assumed asbestos-containing

Additional information for each designated substance identified as well as materials suspected for containing

designated substances can be found within the Analytical Findings and Observations sections of this report.

The following designated substances were not identified within the building located at 6121 Lundy’s Lane, Niagara

Falls, Ontario:

� Acrylonitrile

� Arsenic

� Benzene

� Coke Oven Emissions

� Ethylene Oxide

� Isocyanates

� Vinyl Chloride

The Scope of Work, found in Appendix C, provides the City with guidance on the controlled removal and disposal of

the designated substances identified at 6121 Lundy’s Lane, Niagara Falls, Ontario.

Introduction

Prior to beginning a project, the owner is required to determine whether any designated substances are present at

the project site and shall prepare a list of all designated substances that are present at the site. This report, prepared

by OESN and provided to the City satisfies this requirement.

1


Designated Substances and Select Hazardous Materials Assessment 6121 Lundy’s Lane, Niagara Falls, Ontario

Scope of Work

To produce the information required to meet Section 30 of the Occupational Health and Safety Act, OESN developed

and implemented the following scope of work for the property located at 6121 Lundy’s Lane, Niagara Falls, Ontario:

1. Identify and locate materials suspected of containing designated substances or other potentially hazardous

substances throughout the interior and exterior of the building

2. Collect bulk samples of materials suspected to contain designated substances and submit for analysis

3. Document items suspected of containing designated substances and hazardous materials

4. Document the bulk sampling and inspection methodology, assessment findings, and results of analytical

work

Bulk Sampling and Analysis Methodology

General building assessment techniques and principles were applied for materials suspected of containing

designated substances and select hazardous materials. All accessible materials suspected of containing designated

substances were sampled and analyzed for the purpose of a Designated Substances and Select Hazardous

Materials Assessment.

The determination of materials to be sampled was based on the experience and knowledge of an OESN

representative regarding the historical use of designated substances and hazardous materials in building materials.

Trisha McPherson of OESN carried out the visual inspection and material bulk sampling at 6121 Lundy’s Lane,

Niagara Falls, Ontario.

Bulk Collection Methodology for Asbestos Samples

Asbestos bulk sampling was performed using the method stated in Section 3 of O. Reg. 278/05 as amended.

Sampling strategy for bulk sampling of asbestos included for the development of a homogeneous materials sampling

coding system. Homogeneous is defined as materials similar in composition, colour and texture.

The sampling plan for asbestos has the following coding system:

HF–01

HF – Homogeneous Floor Material (W - Wall, C - Ceiling, T - Thermal, M - Manufacturing)

01 – The first homogeneous floor material sampled

Analysis Methodology for Asbestos Samples

All bulk samples collected during the assessment were sent to CEI Labs for analysis. CEI Labs is accredited by the

National Voluntary Laboratory Accreditation Program (NVLAP). Samples were analyzed using Polarized Light

Microscopy (PLM). Sample preparation and analytical procedures are done in compliance with the procedures

described in U.S. EPA Method 600/R93/116 Method for the Determination of Asbestos in Bulk Building Materials

dated June 1993. Other procedures also utilized to supplement this method are described in Environmental

Laboratory Accreditation Program 198.1. (ELAP 198.1).

Bulk Collection Methodology for Lead, Mercury and Arsenic Samples

Sampling strategy for bulk sampling of lead, mercury and arsenic included for the development of a homogeneous

sampling coding system.

2


Designated Substances and Select Hazardous Materials Assessment 6121 Lundy’s Lane, Niagara Falls, Ontario

The sampling plan for lead, mercury and arsenic has the following coding system:

Pb – Homogeneous material

01 – The first homogeneous bulk material sampled

Pb–01

Analysis Methodology for Lead, Mercury and Arsenic Samples

All bulk paint samples collected were sent to Paracel Laboratories Ltd. Paracel Laboratories Ltd. is accredited by the

Canadian Association for Laboratory Accreditation (CALA).

Sample preparation and analytical procedures are done in compliance with the following analytical methods:

� Metals – EPA 6020 – Digestion, ICP-MS

� Mercury – EPA 7471A – CVAA, digestion

Analytical Findings

Analytical Findings for Asbestos-Containing Materials

Analytical testing determined the asbestos mineral Chrysotile is detected in samples collected within 6121 Lundy’s

Lane, Niagara Falls, Ontario in form of friable and non-friable materials. Friable material is defined as “material that

when dry, can be crumbled, pulverized or powdered by hand pressure, or is crumbled, pulverized or powdered” (O.

Reg. 278/05 as amended). Non-friable is hard in composition and cannot be pulverized under hand pressure.

Analytical testing determined asbestos is detected in the following materials listed in Table 1.

Table 1 – Asbestos-Containing Materials

Information

Material: Linoleum – Octagon Pattern

Assigned Homogeneous No.: HF-04

Analytical Result: 25% Chrysotile

Total Quantity: 2 m 2 (24 ft 2 )

Photo

3


Designated Substances and Select Hazardous Materials Assessment 6121 Lundy’s Lane, Niagara Falls, Ontario

Table 1 – Asbestos-Containing Materials - Continued

Information

Material: Linoleum – Wood & Cream Squares

Assigned Homogeneous No.: HF-06

Analytical Result: 25% Chrysotile

Total Quantity: 17 m 2 (187 ft 2 )

Material: Linoleum – Turquoise & Blue

Assigned Homogeneous No.: HF-07

Analytical Result: 25% Chrysotile

Total Quantity: 6 m 2 (66 ft 2 )

Material: Linoleum A – Below HF-01

Assigned Homogeneous No.: HF-08

Analytical Result: 25% Chrysotile

Total Quantity: 56 m 2 (600 ft 2 )

Material: Linoleum B – Below HF-01

Assigned Homogeneous No.: HF-09

Analytical Result: 25% Chrysotile

Total Quantity: 56 m 2 (600 ft 2 )

Photo

4


Designated Substances and Select Hazardous Materials Assessment 6121 Lundy’s Lane, Niagara Falls, Ontario

Table 1 – Asbestos-Containing Materials - Continued

Information

Material: Texture Coat - Ceiling (Stippled)

Assigned Homogeneous No.: HC-02

Analytical Result: 2% Chrysotile

Total Quantity: 30 m 2 (320 ft 2 )

Material: Paper Backing (Behind Electrical Panel)

Assigned Homogeneous No.: HT-01

Analytical Result: 65% Chrysotile

Total Quantity:


Designated Substances and Select Hazardous Materials Assessment 6121 Lundy’s Lane, Niagara Falls, Ontario

Information

Material: Cement Shingles

Analytical Result: Assumed ACM

Total Quantity: 145m 2 (1,560 ft 2 )

Analytical Findings for Non Asbestos-Containing Materials

Photo

Analytical testing determined asbestos is not detected in the following materials listed in Table 2.

Table 2 – Non Asbestos-Containing Materials

Information

Material: Linoleum – Square Pattern with Flowers

Assigned Homogeneous No.: HF-01

Analytical Result: None Detected

Material: Linoleum – 4” x 4” Square Pattern

Assigned Homogeneous No.: HF-02

Analytical Result: None Detected

Photo

6


Designated Substances and Select Hazardous Materials Assessment 6121 Lundy’s Lane, Niagara Falls, Ontario

Table 2 – Non Asbestos-Containing Materials - Continued

Information

Material: Linoleum – 4” x 8” Rectangle Pattern

Assigned Homogeneous No.: HF-03

Analytical Result: None Detected

Material: Linoleum – Dark Mottles

Assigned Homogeneous No.: HF-05

Analytical Result: None Detected

Material: Floor Tile – Below HF-01

Assigned Homogeneous No.: HF-10

Analytical Result: None Detected

Material: Wall Material

Assigned Homogeneous No.: HW-01

Analytical Result: None Detected

Photo

7


Designated Substances and Select Hazardous Materials Assessment 6121 Lundy’s Lane, Niagara Falls, Ontario

Table 2 – Non Asbestos-Containing Materials - Continued

Information

Material: Paper Wall Material

Assigned Homogeneous No.: HW-02

Analytical Result: None Detected

Material: Plaster Wall/Ceiling

Assigned Homogeneous No.: HW-03

Analytical Result: None Detected

Material: Drywall Board with Joint Filling Compound Wall

Assigned Homogeneous No.: HW-04

Analytical Result: None Detected

Material: Texture Coat – Wall/Ceiling

Assigned Homogeneous No.: HW-05

Analytical Result: None Detected

Photo

8


Designated Substances and Select Hazardous Materials Assessment 6121 Lundy’s Lane, Niagara Falls, Ontario

Table 2 – Non Asbestos-Containing Materials - Continued

Information

Material: 1’ x 1’ Ceiling Tile – Wood/Fibre Based

Assigned Homogeneous No.: HC-01

Analytical Result: None Detected

Material: Attic Insulation

Assigned Homogeneous No.: HM-01

Analytical Result: None Detected

Photo

Laboratory analytical results and original chains of custody for asbestos bulk sampling can be found in Appendix A.

Analytical Findings for Lead, Mercury and Arsenic

Analytical testing determined lead and mercury are present in the paint coatings located at 6121 Lundy’s Lane,

Niagara Falls, Ontario. Table 3 identifies the results for lead, mercury and arsenic analysis.

Table 3 – Paint Coating Results for Lead, Mercury and Arsenic

Information Photo

Description: White Paint

Sample Number: Pb-01

Lead Content: 164 µg/g

Mercury Content: 8 µg/g

Arsenic Content: Below Method Detection Limit

9


Designated Substances and Select Hazardous Materials Assessment 6121 Lundy’s Lane, Niagara Falls, Ontario

Table 3 – Paint Coating Results for Lead, Mercury and Arsenic - Continued

Information Photo

Description: Cream Paint

Sample Number: Pb-02

Lead Content: 277 µg/g

Mercury Content: Below Method Detection Limit

Arsenic Content: Below Method Detection Limit

Description: Cinnamon Paint

Sample Number: Pb-03

Lead Content: 278 µg/g

Mercury Content: 13 µg/g

Arsenic Content: Below Method Detection Limit

Description: Taupe Paint

Sample Number: Pb-04

Lead Content: 40 µg/g

Mercury Content: 11 µg/g

Arsenic Content: Below Method Detection Limit

10


Designated Substances and Select Hazardous Materials Assessment 6121 Lundy’s Lane, Niagara Falls, Ontario

Observations

Observations for Mercury-Containing Items Identified on Site

One (1) mercury-containing thermostat was identified on site. The table below provides a description and the

identification photo of the thermostat identified on site.

Item Identification Photo

One (1) thermostat containing

mercury was observed on the main

floor

Conclusion

In preparation for demolition activities, several designated substances were identified within the property located at

6121 Lundy’s Lane, Niagara Falls, Ontario. They include:

� Asbestos

� Lead

� Mercury

� Silica (suspect)

The information presented in this Designated Substances and Select Hazardous Materials Assessment is based on

observations and analytical testing of bulk samples collected from 6121 Lundy’s Lane, Niagara Falls, Ontario.

Report Close Out

Appendix C of this report provides the City with a Scope of Work, including more extensive recommendations for

the safe handling and disposal of designated substances identified within 6121 Lundy’s Lane, Niagara Falls, Ontario.

For all inquiries regarding the information contained in this report and in the Scope of Work, please contact the office.

Regards,

Trisha McPherson

Field Technician

Hazardous Materials Division

tmcpherson@oesn.net

11


Designated Substances and Select Hazardous Materials Assessment 6121 Lundy’s Lane, Niagara Falls, Ontario

Reviewed by,

Jeff Drummond

Project Manager

Hazardous Materials Division

jdrummond@oesn.net

Limits of the Assessment

This report is intended for the exclusive use of the City of Niagara Falls. Any use that a third party makes of this

report, or any reliance on decisions to be made based on it, is the responsibility of such third parties.

The findings reported in this Designated Substances and Select Hazardous Materials Assessment have been

compiled using current industry best practices and techniques. The findings are relevant for the date of OESN’s site

visit and should not be relied upon to represent conditions at later dates. The findings in this assessment are limited

to the building materials observed in rooms or building spaces fully accessed during the time of inspection. All

materials were assessed at the discretion of the inspectors.

OESN reserves the right to modify any findings reported as a result of insufficient background and historical

information and inaccessibility issues from building condition, design and layout. It is possible that building materials

not identified in this report may become exposed during demolition. Any materials not identified in this report and are

suspected to contain designated substances should be treated as such until sampling and analysis is conducted.

Bulk Sampling Limitations

Bulk sampling of man-made vitreous fibre products, specifically, fibreglass pipe insulation, was not included in the

bulk sampling strategy subsequent to the review of present day MSDS sheets for the product which do not state the

inclusion of asbestos as an ingredient in their manufacture.

Paint coating samples were not submitted for further toxic characteristics leachate procedure (TCLP) analysis since

initial lead results of paint samples indicated a lead concentration of


Appendix A:

Designated Substances and

Select Hazardous Materials Assessment

Analytical Results


Designated Substances and Select Hazardous Materials Assessment 6121 Lundy’s Lane, Niagara Falls, Ontario

Homogeneous Material Numbers for Friable Materials:

Material Homogeneous

Number

Sample Number

Linoleum – Square Pattern with Flowers HF-01 00015.063-F01 (F02, F03)

Linoleum – 4” x 4” Square Pattern HF-02 00015.063-F04 (F05, F06)

Linoleum – 4” x 8” Rectangle Pattern HF-03 00015.063-F07 (F08, F09)

Linoleum – Octagon Pattern HF-04 00015.063-F10 (F11, F12)

Linoleum – Dark Mottles HF-05 00015.063-F13 (F14, F15)

Linoleum – Wood & Cream Squares HF-06 00015.063-F16 (F17, F18)

Linoleum – Turquoise & Blue HF-07 00015.063-F19 (F20, F21)

Linoleum A – Below HF-01 HF-08 00015.063-F22 (F23, F24)

Linoleum B – Below HF-01 HF-09 00015.063-F25 (F26, F27)

Appendix A: Analytical Results

Wall Material HW-01 00015.063-W01 (W02, W03)

Paper Wall Material HW-02 00015.063-W04 (W05, W06)

Plaster Wall/Ceiling HW-03 00015.063-W07 (W08, W09, W10, W11)

Drywall Board with Joint Filling Compound Wall HW-04 00015.063-W12 (W13, W14)

Texture Coat - Wall HW-05 00015.063-W15 (W16, W17)

1’ x 1’ Ceiling Tile – Wood/Fibre Based HC-01 00015.063-C01 (C02, C03)

Texture Coat - Ceiling (Stippled) HC-02 00015.063-C04 (C05, C06)

Paper Backing (Behind Electrical Panel) HT-01 00015.063-T01 (T02, T03)

Attic Insulation HM-01 00015.063-M01 (M02, M03)

Homogeneous Material Numbers for Non-Friable Materials:

Material Homogeneous

Number

Sample Number

Floor Tile – Below HF-01 HF-10 00015.063-F28 (F29, F30)

Homogeneous Material Numbers for Paint Coating Samples:

Material Description Homogeneous and Sample Number

White Paint 00015.063-pb01

Cream Paint 00015.063-pb02

Cinnamon Paint 00015.063-pb03

Taupe Paint 00015.063-pb04


ASBESTOS LABORATORY REPORT

Prepared for

Ontario Environmental & Safety Network, LTD.

PROJECT:

CEI LAB CODE:

DATE REPORTED:

00015.063

A12-5866

07/09/12

TOTAL SAMPLES ANALYZED:

# SAMPLES >1% ASBESTOS:

20

5

TEL: 866-481-1412

www.ceilabs.com


Asbestos Report Summary

By: POLARIZING LIGHT MICROSCOPY

PROJECT: 00015.063 CEI LAB CODE: A12-5866

METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020

Client ID Layer Lab ID Color Sample Description

00015.063-F01

00015.063-F02

00015.063-F03

00015.063-F04

00015.063-F05

00015.063-F06

00015.063-F07

00015.063-F08

00015.063-F09

ASBESTOS

%

A1311434 Off-white Linoleum None Detected

A1311435 Off-white Linoleum None Detected

A1311436 Off-white Linoleum None Detected

A1311437 White Linoleum None Detected

A1311438 White Linoleum None Detected

A1311439 White Linoleum None Detected

A1311440 White Linoleum None Detected

A1311441 White Linoleum None Detected

A1311442 White Linoleum None Detected

00015.063-F10 A1311443 Yellow,Tan Linoleum Chrysotile 25%

00015.063-F11

00015.063-F12

00015.063-F13

00015.063-F14

00015.063-F15

A1311444 Sample Not Analyzed per COC

A1311445 Sample Not Analyzed per COC

A1311446 Grey,Tan Linoleum None Detected

A1311447 Grey,Tan Linoleum None Detected

A1311448 Grey,Tan Linoleum None Detected

00015.063-F16 A1311449 Off-white,Brown Linoleum Chrysotile 25%

00015.063-F17

00015.063-F18

A1311450 Sample Not Analyzed per COC

A1311451 Sample Not Analyzed per COC

00015.063-F19 A1311452 Off-white,Blue Linoleum Chrysotile 25%

00015.063-F20

00015.063-F21

A1311453 Sample Not Analyzed per COC

A1311454 Sample Not Analyzed per COC

00015.063-F22 A1311455 Tan Linoleum Chrysotile 25%

00015.063-F23

00015.063-F24

A1311456 Sample Not Analyzed per COC

A1311457 Sample Not Analyzed per COC

00015.063-F25 A1311458 Tan Linoleum Chrysotile 25%

00015.063-F26

00015.063-F27

00015.063-F28

00015.063-F29

A1311459 Sample Not Analyzed per COC

A1311460 Sample Not Analyzed per COC

A1311461A Tan Floor Tile None Detected

A1311461B Black Mastic None Detected

A1311462A Tan Floor Tile None Detected

A1311462B Black Mastic None Detected

Page 1 of 2


Asbestos Report Summary

By: POLARIZING LIGHT MICROSCOPY

PROJECT: 00015.063 CEI LAB CODE: A12-5866

METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020

Client ID Layer Lab ID Color Sample Description

00015.063-F30

ASBESTOS

%

A1311463A Tan Floor Tile None Detected

A1311463B Black Mastic None Detected

Page 2 of 2


Client: Ontario Environmental & Safety Network, LTD.

RR #2

1783 Highway 20C

Allanburg, ON L0S 1A0

Project: 00015.063

ASBESTOS BULK PLM, EPA 600 METHOD

Client ID

Lab ID

00015.063-

F01

A1311434

00015.063-

F02

A1311435

00015.063-

F03

A1311436

00015.063-

F04

A1311437

00015.063-

F05

A1311438

00015.063-

F06

A1311439

00015.063-

F07

A1311440

00015.063-

F08

A1311441

Lab

Description

Linoleum

Linoleum

Linoleum

Linoleum

Linoleum

Linoleum

Linoleum

Linoleum

Lab

Attributes

Heterogeneous

Off-white

Fibrous

Bound

Heterogeneous

Off-white

Fibrous

Bound

Heterogeneous

Off-white

Fibrous

Bound

Heterogeneous

White

Fibrous

Bound

Heterogeneous

White

Fibrous

Bound

Heterogeneous

White

Fibrous

Bound

Heterogeneous

White

Fibrous

Bound

Heterogeneous

White

Fibrous

Bound

ASBESTOS BULK ANALYSIS

By: POLARIZING LIGHT MICROSCOPY

NON-ASBESTOS COMPONENTS

Fibrous

Non-Fibrous

30%

10%

30%

10%

30%

10%

30%

10%

30%

10%

30%

10%

30%

10%

30%

10%

Cellulose

Fiberglass

Cellulose

Fiberglass

Cellulose

Fiberglass

Cellulose

Fiberglass

Cellulose

Fiberglass

Cellulose

Fiberglass

Cellulose

Fiberglass

Cellulose

Fiberglass

30%

30%

30%

30%

30%

30%

30%

30%

30%

30%

30%

30%

30%

30%

30%

30%

CEI Lab Code: A12-5866

Date Received: 07-06-12

Date Reported: 07-06-12

Binder

Vinyl

Binder

Vinyl

Binder

Vinyl

Binder

Vinyl

Binder

Vinyl

Binder

Vinyl

Binder

Vinyl

Binder

Vinyl

ASBESTOS

%

None Detected

None Detected

None Detected

None Detected

None Detected

None Detected

None Detected

None Detected

Page 1 of 5


Client: Ontario Environmental & Safety Network, LTD.

RR #2

1783 Highway 20C

Allanburg, ON L0S 1A0

Project: 00015.063

ASBESTOS BULK PLM, EPA 600 METHOD

Client ID

Lab ID

00015.063-

F09

A1311442

00015.063-

F10

A1311443

00015.063-

F11

A1311444

00015.063-

F12

A1311445

00015.063-

F13

A1311446

00015.063-

F14

A1311447

00015.063-

F15

A1311448

00015.063-

F16

A1311449

Lab

Description

Linoleum

Linoleum

Sample Not Analyzed

per COC

Sample Not Analyzed

per COC

Linoleum

Linoleum

Linoleum

Linoleum

Lab

Attributes

Heterogeneous

White

Fibrous

Bound

Heterogeneous

Yellow,Tan

Fibrous

Bound

Heterogeneous

Grey,Tan

Fibrous

Bound

Heterogeneous

Grey,Tan

Fibrous

Bound

Heterogeneous

Grey,Tan

Fibrous

Bound

Heterogeneous

Off-white,Brown

Fibrous

Bound

ASBESTOS BULK ANALYSIS

By: POLARIZING LIGHT MICROSCOPY

NON-ASBESTOS COMPONENTS

Fibrous

Non-Fibrous

30%

10%

15%

40%

40%

40%

15%

Cellulose

Fiberglass

30%

30%

CEI Lab Code: A12-5866

Date Received: 07-06-12

Date Reported: 07-06-12

Binder

Vinyl

Cellulose 30% Binder

30% Vinyl

Cellulose 30% Tar

30% Vinyl

Cellulose 30% Tar

30% Vinyl

Cellulose 30% Tar

30% Vinyl

Cellulose 30% Binder

30% Vinyl

ASBESTOS

%

None Detected

25% Chrysotile

None Detected

None Detected

None Detected

25% Chrysotile

Page 2 of 5


Client: Ontario Environmental & Safety Network, LTD.

RR #2

1783 Highway 20C

Allanburg, ON L0S 1A0

Project: 00015.063

ASBESTOS BULK PLM, EPA 600 METHOD

Client ID

Lab ID

00015.063-

F17

A1311450

00015.063-

F18

A1311451

00015.063-

F19

A1311452

00015.063-

F20

A1311453

00015.063-

F21

A1311454

00015.063-

F22

A1311455

00015.063-

F23

A1311456

00015.063-

F24

A1311457

00015.063-

F25

A1311458

Lab

Description

Sample Not Analyzed

per COC

Sample Not Analyzed

per COC

Linoleum

Sample Not Analyzed

per COC

Sample Not Analyzed

per COC

Linoleum

Sample Not Analyzed

per COC

Sample Not Analyzed

per COC

Linoleum

Lab

Attributes

Heterogeneous

Off-white,Blue

Fibrous

Bound

Heterogeneous

Tan

Fibrous

Bound

Heterogeneous

Tan

Fibrous

Bound

ASBESTOS BULK ANALYSIS

By: POLARIZING LIGHT MICROSCOPY

NON-ASBESTOS COMPONENTS

Fibrous

Non-Fibrous

10%

15%

15%

Cellulose Binder

30%

30%

5%

CEI Lab Code: A12-5866

Date Received: 07-06-12

Date Reported: 07-06-12

Vinyl

Mastic

Cellulose 30% Binder

30% Vinyl

Cellulose 30% Binder

30% Vinyl

ASBESTOS

%

25% Chrysotile

25% Chrysotile

25% Chrysotile

Page 3 of 5


Client: Ontario Environmental & Safety Network, LTD.

RR #2

1783 Highway 20C

Allanburg, ON L0S 1A0

Project: 00015.063

ASBESTOS BULK PLM, EPA 600 METHOD

Client ID

Lab ID

00015.063-

F26

A1311459

00015.063-

F27

A1311460

00015.063-

F28

A1311461A

Lab

Description

Sample Not Analyzed

per COC

Sample Not Analyzed

per COC

Floor Tile

Lab

Attributes

Heterogeneous

Tan

Non-fibrous

Bound

A1311461B Mastic

Heterogeneous

Black

Non-fibrous

Bound

00015.063-

F29

A1311462A

Floor Tile

Heterogeneous

Tan

Non-fibrous

Bound

A1311462B Mastic

Heterogeneous

Black

Non-fibrous

Bound

00015.063-

F30

A1311463A

Floor Tile

Heterogeneous

Tan

Non-fibrous

Bound

A1311463B Mastic

Heterogeneous

Black

Non-fibrous

Bound

ASBESTOS BULK ANALYSIS

By: POLARIZING LIGHT MICROSCOPY

NON-ASBESTOS COMPONENTS

Fibrous

Non-Fibrous

CEI Lab Code: A12-5866

Date Received: 07-06-12

Date Reported: 07-06-12

ASBESTOS

%

100% Vinyl None Detected

100% Tar None Detected

100% Vinyl None Detected

100% Tar None Detected

100% Vinyl None Detected

100% Tar None Detected

Page 4 of 5


LEGEND: Non-Anth = Non-Asbestiform Anthophylite

Non-Trem = Non-Asbestiform Tremolite

Calc Carb = Calcium Carbonate

METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020

The detection limit for the method is


ASBESTOS LABORATORY REPORT

Prepared for

Ontario Environmental & Safety Network, LTD.

PROJECT:

CEI LAB CODE:

DATE REPORTED:

00015.063

A12-5867

07/09/12

TOTAL SAMPLES ANALYZED:

# SAMPLES >1% ASBESTOS:

17

TEL: 866-481-1412

www.ceilabs.com


Asbestos Report Summary

By: POLARIZING LIGHT MICROSCOPY

PROJECT: 00015.063 CEI LAB CODE: A12-5867

METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020

Client ID Layer Lab ID Color Sample Description

00015.063-W01

00015.063-W02

00015.063-W03

00015.063-W04

00015.063-W05

00015.063-W06

00015.063-W07

00015.063-W08

00015.063-W09

00015.063-W10

00015.063-W11

00015.063-W12

00015.063-W13

00015.063-W14

00015.063-W15

00015.063-W16

00015.063-W17

ASBESTOS

%

A1311464 Off-white Wall Material None Detected

A1311465 Off-white Wall Material None Detected

A1311466 Off-white Wall Material None Detected

A1311467 Tan Wall Material None Detected

A1311468 Tan Wall Material None Detected

A1311469 Tan Wall Material None Detected

Layer 1 A1311470 White Plaster Skim Coat None Detected

Layer 2 A1311470 Grey Plaster Base Coat None Detected

Layer 1 A1311471 White Plaster Skim Coat None Detected

Layer 2 A1311471 Grey Plaster Base Coat None Detected

Layer 1 A1311472 White Plaster Skim Coat None Detected

Layer 2 A1311472 Grey Plaster Base Coat None Detected

Layer 1 A1311473 White Plaster Skim Coat None Detected

Layer 2 A1311473 Grey Plaster Base Coat None Detected

Layer 1 A1311474 White Plaster Skim Coat None Detected

Layer 2 A1311474 Grey Plaster Base Coat None Detected

A1311475 White,Tan Drywall None Detected

Layer 2 A1311475 White,Tan Joint Compound None Detected

A1311476 White,Tan Drywall None Detected

Layer 2 A1311476 White,Tan Joint Compound None Detected

A1311477 White,Tan Drywall None Detected

Layer 2 A1311477 White,Tan Joint Compound None Detected

A1311478 Orange,Offwhite

A1311479 Orange,Offwhite

A1311480 Orange,Offwhite

Texture None Detected

Texture None Detected

Texture None Detected

Page 1 of 1


Client: Ontario Environmental & Safety Network, LTD.

RR #2

1783 Highway 20C

Allanburg, ON L0S 1A0

Project: 00015.063

ASBESTOS BULK PLM, EPA 600 METHOD

Client ID

Lab ID

00015.063-

W01

A1311464

00015.063-

W02

A1311465

00015.063-

W03

A1311466

00015.063-

W04

A1311467

00015.063-

W05

A1311468

00015.063-

W06

A1311469

Lab

Description

Wall Material

Wall Material

Wall Material

Wall Material

Wall Material

Wall Material

00015.063-

W07

Layer 1 Plaster Skim Coat

A1311470

Layer 2

A1311470

Plaster Base Coat

Lab

Attributes

Heterogeneous

Off-white

Non-fibrous

Bound

Heterogeneous

Off-white

Non-fibrous

Bound

Heterogeneous

Off-white

Non-fibrous

Bound

Heterogeneous

Tan

Fibrous

Loosely Bound

Heterogeneous

Tan

Fibrous

Loosely Bound

Heterogeneous

Tan

Fibrous

Loosely Bound

Heterogeneous

White

Non-fibrous

Bound

Heterogeneous

Grey

Non-fibrous

Bound

ASBESTOS BULK ANALYSIS

By: POLARIZING LIGHT MICROSCOPY

NON-ASBESTOS COMPONENTS

Fibrous

Non-Fibrous

90%

90%

90%

50%

40%

10%

50%

40%

10%

50%

40%

10%

CEI Lab Code: A12-5867

Date Received: 07-06-12

Date Reported: 07-09-12

Binder

Calc Carb

Paint

Binder

Calc Carb

Paint

Binder

Calc Carb

Paint

Cellulose 5% Binder

5% Paint

Cellulose 5% Binder

5% Paint

Cellulose 5% Binder

5% Paint

60%

35%

5%

40%

60%

Binder

Silicates

Paint

Binder

Silicates

ASBESTOS

%

None Detected

None Detected

None Detected

None Detected

None Detected

None Detected

None Detected

None Detected

Page 1 of 5


Client: Ontario Environmental & Safety Network, LTD.

RR #2

1783 Highway 20C

Allanburg, ON L0S 1A0

Project: 00015.063

ASBESTOS BULK PLM, EPA 600 METHOD

Client ID

Lab ID

Lab

Description

00015.063-

W08

Layer 1 Plaster Skim Coat

A1311471

Layer 2

A1311471

Plaster Base Coat

00015.063-

W09

Layer 1 Plaster Skim Coat

A1311472

Layer 2

A1311472

Plaster Base Coat

00015.063-

W10

Layer 1 Plaster Skim Coat

A1311473

Layer 2

A1311473

Plaster Base Coat

00015.063-

W11

Layer 1 Plaster Skim Coat

A1311474

Layer 2

A1311474

Plaster Base Coat

Lab

Attributes

Heterogeneous

White

Non-fibrous

Bound

Heterogeneous

Grey

Non-fibrous

Bound

Heterogeneous

White

Non-fibrous

Bound

Heterogeneous

Grey

Non-fibrous

Bound

Heterogeneous

White

Non-fibrous

Bound

Heterogeneous

Grey

Non-fibrous

Bound

Heterogeneous

White

Non-fibrous

Bound

Heterogeneous

Grey

Non-fibrous

Bound

ASBESTOS BULK ANALYSIS

By: POLARIZING LIGHT MICROSCOPY

NON-ASBESTOS COMPONENTS

Fibrous

Non-Fibrous

60%

35%

5%

40%

60%

60%

35%

5%

40%

60%

60%

35%

5%

40%

60%

60%

35%

5%

40%

60%

CEI Lab Code: A12-5867

Date Received: 07-06-12

Date Reported: 07-09-12

Binder

Silicates

Paint

Binder

Silicates

Binder

Silicates

Paint

Binder

Silicates

Binder

Silicates

Paint

Binder

Silicates

Binder

Silicates

Paint

Binder

Silicates

ASBESTOS

%

None Detected

None Detected

None Detected

None Detected

None Detected

None Detected

None Detected

None Detected

Page 2 of 5


Client: Ontario Environmental & Safety Network, LTD.

RR #2

1783 Highway 20C

Allanburg, ON L0S 1A0

Project: 00015.063

ASBESTOS BULK PLM, EPA 600 METHOD

Client ID

Lab ID

00015.063-

W12

A1311475

Layer 2

A1311475

00015.063-

W13

A1311476

Layer 2

A1311476

00015.063-

W14

A1311477

Layer 2

A1311477

00015.063-

W15

A1311478

00015.063-

W16

A1311479

Lab

Description

Drywall

Joint Compound

Drywall

Joint Compound

Drywall

Joint Compound

Texture

Texture

Lab

Attributes

Heterogeneous

White,Tan

Fibrous

Bound

Heterogeneous

White,Tan

Fibrous

Bound

Heterogeneous

White,Tan

Fibrous

Bound

Heterogeneous

White,Tan

Fibrous

Bound

Heterogeneous

White,Tan

Fibrous

Bound

Heterogeneous

White,Tan

Fibrous

Bound

Heterogeneous

Orange,Off-white

Fibrous

Bound

Heterogeneous

Orange,Off-white

Fibrous

Bound

ASBESTOS BULK ANALYSIS

By: POLARIZING LIGHT MICROSCOPY

NON-ASBESTOS COMPONENTS

Fibrous

Non-Fibrous

20%

20%

20%

CEI Lab Code: A12-5867

Date Received: 07-06-12

Date Reported: 07-09-12

ASBESTOS

%

Cellulose 80% Gypsum None Detected

60%

5%

35%

Binder

Paint

Calc Carb

None Detected

Cellulose 80% Gypsum None Detected

60%

5%

35%

Binder

Paint

Calc Carb

None Detected

Cellulose 80% Gypsum None Detected

60%

5%

35%

40%

30%

30%

40%

30%

30%

Binder

Paint

Calc Carb

Binder

Paint

Calc Carb

Binder

Paint

Calc Carb

None Detected

None Detected

None Detected

Page 3 of 5


Client: Ontario Environmental & Safety Network, LTD.

RR #2

1783 Highway 20C

Allanburg, ON L0S 1A0

Project: 00015.063

ASBESTOS BULK PLM, EPA 600 METHOD

Client ID

Lab ID

00015.063-

W17

A1311480

Lab

Description

Texture

Lab

Attributes

Heterogeneous

Orange,Off-white

Fibrous

Bound

ASBESTOS BULK ANALYSIS

By: POLARIZING LIGHT MICROSCOPY

NON-ASBESTOS COMPONENTS

Fibrous

Non-Fibrous

40%

30%

30%

CEI Lab Code: A12-5867

Date Received: 07-06-12

Date Reported: 07-09-12

Binder

Paint

Calc Carb

ASBESTOS

%

None Detected

Page 4 of 5


LEGEND: Non-Anth = Non-Asbestiform Anthophylite

Non-Trem = Non-Asbestiform Tremolite

Calc Carb = Calcium Carbonate

METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020

The detection limit for the method is


ASBESTOS LABORATORY REPORT

Prepared for

Ontario Environmental & Safety Network, LTD.

PROJECT:

CEI LAB CODE:

DATE REPORTED:

00015.063

A12-5869

07/09/12

TOTAL SAMPLES ANALYZED:

# SAMPLES >1% ASBESTOS:

4

1

TEL: 866-481-1412

www.ceilabs.com


Asbestos Report Summary

By: POLARIZING LIGHT MICROSCOPY

PROJECT: 00015.063 CEI LAB CODE: A12-5869

METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020

Client ID Layer Lab ID Color Sample Description

00015.063-C01

00015.063-C02

00015.063-C03

ASBESTOS

%

A1311484 White,Tan Ceiling Tile None Detected

A1311485 White,Tan Ceiling Tile None Detected

A1311486 White,Tan Ceiling Tile None Detected

00015.063-C04 A1311487 White Texture Chrysotile 2%

00015.063-C05

00015.063-C06

A1311488 Sample Not Analyzed per COC

A1311489 Sample Not Analyzed per COC

Page 1 of 1


Client: Ontario Environmental & Safety Network, LTD.

RR #2

1783 Highway 20C

Allanburg, ON L0S 1A0

Project: 00015.063

ASBESTOS BULK PLM, EPA 600 METHOD

Client ID

Lab ID

00015.063-

C01

A1311484

00015.063-

C02

A1311485

00015.063-

C03

A1311486

00015.063-

C04

A1311487

00015.063-

C05

A1311488

00015.063-

C06

A1311489

Lab

Description

Ceiling Tile

Ceiling Tile

Ceiling Tile

Texture

Sample Not Analyzed

per COC

Sample Not Analyzed

per COC

Lab

Attributes

Heterogeneous

White,Tan

Fibrous

Loosely Bound

Heterogeneous

White,Tan

Fibrous

Loosely Bound

Heterogeneous

White,Tan

Fibrous

Loosely Bound

Heterogeneous

White

Fibrous

Bound

ASBESTOS BULK ANALYSIS

By: POLARIZING LIGHT MICROSCOPY

NON-ASBESTOS COMPONENTS

Fibrous

Non-Fibrous

90%

90%

90%

Cellulose 5% Binder

5% Paint

Cellulose 5% Binder

5% Paint

Cellulose 5% Binder

5% Paint

60%

5%

33%

CEI Lab Code: A12-5869

Date Received: 07-06-12

Date Reported: 07-06-12

Binder

Paint

Calc Carb

ASBESTOS

%

None Detected

None Detected

None Detected

2% Chrysotile

Page 1 of 2


LEGEND: Non-Anth = Non-Asbestiform Anthophylite

Non-Trem = Non-Asbestiform Tremolite

Calc Carb = Calcium Carbonate

METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020

The detection limit for the method is


ASBESTOS LABORATORY REPORT

Prepared for

Ontario Environmental & Safety Network, LTD.

PROJECT:

CEI LAB CODE:

DATE REPORTED:

00015.063

A12-5870

07/09/12

TOTAL SAMPLES ANALYZED:

# SAMPLES >1% ASBESTOS:

1

1

TEL: 866-481-1412

www.ceilabs.com


Asbestos Report Summary

By: POLARIZING LIGHT MICROSCOPY

PROJECT: 00015.063 CEI LAB CODE: A12-5870

METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020

Client ID Layer Lab ID Color Sample Description

ASBESTOS

%

00015.063-T01 A1311490 Tan Paper Chrysotile 65%

00015.063-T02

00015.063-T03

A1311491 Sample Not Analyzed per COC

A1311492 Sample Not Analyzed per COC

Page 1 of 1


Client: Ontario Environmental & Safety Network, LTD.

RR #2

1783 Highway 20C

Allanburg, ON L0S 1A0

Project: 00015.063

ASBESTOS BULK PLM, EPA 600 METHOD

Client ID

Lab ID

00015.063-

T01

A1311490

00015.063-

T02

A1311491

00015.063-

T03

A1311492

Lab

Description

Paper

Sample Not Analyzed

per COC

Sample Not Analyzed

per COC

Lab

Attributes

Heterogeneous

Tan

Fibrous

Loosely Bound

ASBESTOS BULK ANALYSIS

By: POLARIZING LIGHT MICROSCOPY

NON-ASBESTOS COMPONENTS

Fibrous

Non-Fibrous

20%

CEI Lab Code: A12-5870

Date Received: 07-06-12

Date Reported: 07-06-12

ASBESTOS

%

Cellulose 15% Binder 65% Chrysotile

Page 1 of 2


LEGEND: Non-Anth = Non-Asbestiform Anthophylite

Non-Trem = Non-Asbestiform Tremolite

Calc Carb = Calcium Carbonate

METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020

The detection limit for the method is


ASBESTOS LABORATORY REPORT

Prepared for

Ontario Environmental & Safety Network, LTD.

PROJECT:

CEI LAB CODE:

DATE REPORTED:

00015.063

A12-5868

07/09/12

TOTAL SAMPLES ANALYZED:

# SAMPLES >1% ASBESTOS:

3

TEL: 866-481-1412

www.ceilabs.com


Asbestos Report Summary

By: POLARIZING LIGHT MICROSCOPY

PROJECT: 00015.063 CEI LAB CODE: A12-5868

METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020

Client ID Layer Lab ID Color Sample Description

00015.063-M01

00015.063-M02

00015.063-M03

ASBESTOS

%

A1311481 Tan Insulation None Detected

A1311482 Tan Insulation None Detected

A1311483 Tan Insulation None Detected

Page 1 of 1


Client: Ontario Environmental & Safety Network, LTD.

RR #2

1783 Highway 20C

Allanburg, ON L0S 1A0

Project: 00015.063

ASBESTOS BULK PLM, EPA 600 METHOD

Client ID

Lab ID

00015.063-

M01

A1311481

00015.063-

M02

A1311482

00015.063-

M03

A1311483

Lab

Description

Insulation

Insulation

Insulation

Lab

Attributes

Heterogeneous

Tan

Fibrous

Loosely Bound

Heterogeneous

Tan

Fibrous

Loosely Bound

Heterogeneous

Tan

Fibrous

Loosely Bound

ASBESTOS BULK ANALYSIS

By: POLARIZING LIGHT MICROSCOPY

NON-ASBESTOS COMPONENTS

Fibrous

Non-Fibrous

100%

100%

100%

CEI Lab Code: A12-5868

Date Received: 07-06-12

Date Reported: 07-06-12

ASBESTOS

%

Cellulose None Detected

Cellulose None Detected

Cellulose None Detected

Page 1 of 2


LEGEND: Non-Anth = Non-Asbestiform Anthophylite

Non-Trem = Non-Asbestiform Tremolite

Calc Carb = Calcium Carbonate

METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020

The detection limit for the method is


Ontario Environmental & Safety Network Ltd. (St.)

16-22 Secord Drive

St. Catharines, ON L2N 1K8

Attn: Lisa Tappay

Client PO:

Project: 00015.063

Custody: 0753

Certificate of Analysis

Phone: (905) 988-1554

Fax: (905) 988-1910

Report Date: 11-Jul-2012

Order Date: 5-Jul-2012

This Certificate of Analysis contains analytical data applicable to the following samples as submitted:

Paracel ID Client ID

1227169-01 pb01-White-Basement

1227169-02 pb02-Cream-Main Floor

1227169-03 pb03-Cinnamon-2nd Floor

1227169-04 pb04-Taupe-2nd Floor

Approved By:

Dale Robertson, BSc

Laboratory Director

Order #: 1227169

Any use of these results implies your agreement that our total liabilty in connection with this work, however arising shall be limited to the amount paid by you

for this work, and that our employees or agents shall not under circumstances be liable to you in connection with this work

Page 1 of 7


Certificate of Analysis

Client: Ontario Environmental & Safety Network Ltd. (St.)

Client PO: Project Description: 00015.063

Analysis Summary Table

Order #: 1227169

Report Date: 11‐Jul‐2012

Order Date:5‐Jul‐2012

Analysis Method Reference/Description Extraction Date Analysis Date

Mercury

EPA 7471A - CVAA, digestion 9-Jul-12 9-Jul-12

Metals

EPA 6020 - Digestion, ICP-MS 9-Jul-12 9-Jul-12

Page 2 of 7


Order #: 1227169

Certificate of Analysis

Report Date: 11‐Jul‐2012

Client: Ontario Environmental & Safety Network Ltd. (St.)

Order Date:5‐Jul‐2012

Client PO: Project Description: 00015.063

Client ID: pb01-White-Basement pb02-Cream-Main pb03-Cinnamon-2nd pb04-Taupe-2nd

Floor

Floor

Floor

Sample Date: 05-Jul-12

05-Jul-12

05-Jul-12

05-Jul-12

Sample ID: 1227169-01 1227169-02 1227169-03 1227169-04

MDL/Units Paint Paint Paint Paint

Metals

Arsenic 50 ug/g


Certificate of Analysis

Client: Ontario Environmental & Safety Network Ltd. (St.)

Client PO: Project Description: 00015.063

Method Quality Control: Blank

Analyte Result

Reporting

Limit Units

Metals

Arsenic ND 50 ug/g

Lead ND 5 ug/g

Mercury ND 2 ug/g

Source

Result %REC

%REC

Limit RPD

Order #: 1227169

Report Date: 11‐Jul‐2012

Order Date:5‐Jul‐2012

RPD

Limit Notes

Page 4 of 7


Certificate of Analysis

Client: Ontario Environmental & Safety Network Ltd. (St.)

Client PO: Project Description: 00015.063

Method Quality Control: Duplicate

Analyte Result

Metals

Reporting

Limit Units

Source

Result %REC

%REC

Limit RPD

Arsenic ND 50 ug/g ND 0.0 50

Lead 4190 5 ug/g 4170 0.5 50

Mercury ND 2 ug/g ND 0.0 35

Order #: 1227169

Report Date: 11‐Jul‐2012

Order Date:5‐Jul‐2012

RPD

Limit Notes

Page 5 of 7


Certificate of Analysis

Client: Ontario Environmental & Safety Network Ltd. (St.)

Client PO: Project Description: 00015.063

Method Quality Control: Spike

Analyte

Metals

Result

Reporting

Limit

Units

Source

Result

%REC

%REC

Limit

Arsenic 48.7 ug/L 0.04 97.3 70-130

Lead 210 ug/L 167 85.7 70-130

Mercury 13.2 2 ug/g ND 88.2 70-130

Order #: 1227169

Report Date: 11‐Jul‐2012

Order Date:5‐Jul‐2012

RPD

RPD

Limit

Notes

Page 6 of 7


Certificate of Analysis

Client: Ontario Environmental & Safety Network Ltd. (St.)

Client PO: Project Description: 00015.063

Qualifier Notes:

None

Sample Data Revisions

None

Work Order Revisions / Comments:

None

Other Report Notes:

n/a: not applicable

MDL: Method Detection Limit

Source Result: Data used as source for matrix and duplicate samples

%REC: Percent recovery.

RPD: Relative percent difference.

Order #: 1227169

Report Date: 11‐Jul‐2012

Order Date:5‐Jul‐2012

Page 7 of 7


Appendix B:

Designated Substances and

Select Hazardous Materials Assessment

Location Drawings


EXTERIOR

9

UP

Pb

01

Hg

01

8

7

BASEMENT

10 4 16

14 5 20

Pb

01

Hg

01

15

NON ASBESTOS-CONTAINING

MATERIALS

10 LINOLEUM - HF-01

14

FLOOR TILE - HF-10

15 WALL MATERIAL - HW-01

16 PAPER WALL MATERIAL - HW-02

20

1'x1' CEILING TILE WOOD/FIBRE

BASED - HC-01

CITY OF NIAGARA FALLS

Pb

01

Hg

02

4

5

7

8

6121 LUNDY'S LANE

NIAGARA FALLS, ON

L2G 1T4

LEGEND

LEAD-CONTAINING PAINT

MERCURY-CONTAINING PAINT

ASBESTOS-CONTAINING

MATERIALS

LINOLEUM - HF-08

LINOLEUM - HF-09

PAPER BACKING (BEHIND

ELECTRICAL PANEL) - HT-01

COATING UNDER STAINLESS

STEEL SINK (BLACK)

9 CEMENT SHINGLES

00015.063

6121LL-2012-01


EXTERIOR

9

DN

Pb

02

13

UP

Pb

02

6

17 18

17

18

Hg

T

11

Pb

02

12

17

17

11

Pb

02

8

MAIN FLOOR

1

GARAGE

NON ASBESTOS-CONTAINING

MATERIALS

11 LINOLEUM - HF-02

12

LINOLEUM - HF-03

13 LINOLEUM - HF-05

17 PLASTER - WALL/CEILING HW-03

18

17

Pb

02

DRYWALL BOARD WITH JOINT

FILLING COMPOUND WALL -

HW-04

CITY OF NIAGARA FALLS

Pb

01

Hg

02

Hg

T

1

6

8

6121 LUNDY'S LANE

NIAGARA FALLS, ON

L2G 1T4

LEGEND

LEAD-CONTAINING PAINT

MERCURY-CONTAINING PAINT

MERCURY-CONTAINING

THERMOSTAT

ASBESTOS-CONTAINING

MATERIALS

LINOLEUM - HF-04

TEXTURE COAT - CEILING

(STIPPLED) HC-02

COATING UNDER STAINLESS

STEEL SINK (BLACK)

9 CEMENT SHINGLES

00015.063

6121LL-2012-02


EXTERIOR

9

Pb

04

Hg

04

17

3

Pb

03

Hg

03

19

17 17 17

17

2

2

17

Pb

02

Pb

02

17

2

SECOND FLOOR

Pb

02

21

ATTIC SPACE

CITY OF NIAGARA FALLS

Pb

01

Hg

02

2

3

9

6121 LUNDY'S LANE

NIAGARA FALLS, ON

L2G 1T4

LEGEND

LEAD-CONTAINING PAINT

MERCURY-CONTAINING PAINT

ASBESTOS-CONTAINING

MATERIALS

LINOLEUM - HF-06

LINOLEUM - HF-07

CEMENT SHINGLES

NON ASBESTOS-CONTAINING

MATERIALS

17 PLASTER - WALL/CEILING HW-03

19

TEXTURE COAT WALL / CEILING

- HW-05

21 ATTIC INSULATION - HM-01

00015.063

6121LL-2012-03


Appendix C:

Designated Substances and

Select Hazardous Materials Assessment

Scope of Work


Scope of Work for the Removal of Identified Designated Substances

City of Niagara Falls6121 Lundy’s Lane, Niagara Falls, ON

City of Niagara Falls

6121 Lundy’s Lane, Niagara Falls, ON

Scope of Work for the Removal of Identified Designated Substances

INTRODUCTION

PROJECT BACKGROUND:

In July 2012, Ontario Environmental & Safety Network Ltd. (herein referred to as OESN) was retained by

the City of Niagara Falls (herein referred to as the City) to perform a designated substance assessment

within the property located at 6121 Lundy’s Lane, Niagara Falls, Ontario.

The purpose of assessment was to identify for the presence of designated substances as per Section 30

of the Ontario Occupational Health and Safety Act and Regulations for Construction Projects, which

states before beginning a project, the Owner shall determine whether any designated substances are

present at the project site.

Assessment concluded that asbestos, lead, mercury and silica are present at the project site and

represent a hazard for worker.

Based on future demolition plans, OESN was requested to provide the City with a scope of work for the

safe removal of the designated substances and hazardous materials identified during the assessment.

PROJECT OBJECTIVE:

The goal of this scope of work is to provide information necessary for the safe handling, removal and

disposal of the designated substances and hazardous materials identified during the assessment. The

scope of work is intended to direct the contractors executing the abatement work but does not supplant

existing provincial legislation, regulations, guidelines and policies.

Materials of concern are to be removed in a safe and controlled manner as per the requirements stated

in the following regulations and guidelines:

� Regulation respecting Asbestos on Construction Projects and in Buildings and Repair Operations

– O. Reg. 278/05 (as amended)

� Guideline - Silica on Construction Projects


Scope of Work for the Removal of Identified Designated Substances

City of Niagara Falls6121 Lundy’s Lane, Niagara Falls, ON

PROJECT CLASSIFICATION OF WORK:

Classifications for abatement work have been segregated by hazard material type (e.g asbestos, silica,

etc.). If abatement of designated substances is conducted simultaneously, the measures and procedures

established for the Type 3 asbestos operation are adequate for abatement of other materials other than

asbestos.

ASBESTOS ABATEMENT:

Ontario Regulation 278/05 (as amended) requires that all work that may expose a worker to asbestos be

classified as a Type 1, Type 2, or Type 3 operation. The criteria for classification of work factors in the

type and nature of material (friable/material easily crumbles), nature of disturbance activity (cutting

material), quantity of material to be removed (< or > 1 m 2 ), duration of exposure to worker and risk to

bystanders (re-occupancy of work area(s) by building occupants).

The asbestos abatement work at the project site is classified as: Type 3 Operation

LEAD ABATEMENT:

The classification of typical lead-containing construction tasks is based on presumed airborne

concentrations obtained from the U.S. Occupational Safety and Health Administration (OSHA), the

Ontario Ministry of Labour, and published research studies. The classification of Type 1, Type 2, or Type

3 operations are grouped based on the concentrations of airborne lead that a worker may be exposed to

during typical construction operations that generate lead-containing dust.

The OSHA Lead Standard does not define lead paint based on the amount of lead present. That is, the

standard does not specify a minimum amount or concentration of lead that triggers a determination

that lead is present and the potential for occupational exposure exists. It is theoretically not possible to

exceed the OSHA permissible exposure limit of 50 µg/m 3 , eight-hour time-weighted average (TWA) if

lead content is ≤600 ppm.

All paint coatings sampled at the project site were


Scope of Work for the Removal of Identified Designated Substances

City of Niagara Falls6121 Lundy’s Lane, Niagara Falls, ON

RELATED PROJECT DOCUMENTS:

� Designated Substances and Select Hazardous Materials Assessment Report within 6121

Lundy’s Lane, Niagara Falls, Ontario. July 2012

APPLICABLE LEGISLATION AND GUIDELINE DOCUMENTS:

Ontario Regulation 213/91 (as amended) Occupational Health and Safety Act - Construction

Projects

Ontario Regulation 490/09 (as amended) - Designated Substance - Asbestos

Ontario Regulation 490/09 (as amended) - Designated Substance - Lead

Ontario Regulation 490/09 (as amended) - Designated Substance - Mercury

Ontario Regulation 490/09 (as amended) - Designated Substance - Silica

Ontario Regulation 278/05 (as amended) - Regulation respecting Asbestos on Construction

Projects and in Buildings and Repair Operations

� Guideline - Silica on Construction Projects

Ontario Regulation 347 made under the Environmental Protection Act (as amended) (for the

handling and disposal of contaminated waste)

� The Transportation and Dangerous Goods Act

� WHMIS

SCOPE OF ABATEMENT WORK

In accordance with the Occupational Health & Safety Act (OSHA), the following is a list of designated

substances and hazardous materials affected during demolition:

� Asbestos:

o Friable Linoleum (approximately 137m 2 or 1477 ft 2 )

o Friable Stippled Texture Coat - Ceiling (approximately 30 m 2 or 320 ft 2 )

o Friable Paper Backing Behind Electrical Panel (approximately


Scope of Work for the Removal of Identified Designated Substances

City of Niagara Falls6121 Lundy’s Lane, Niagara Falls, ON

CONTROLS FOR PROJECT

KEY HAZARD INFORMATION:

Once abatement begins, access to the inside of the building shall be restricted to workers involved in the

abatement operation. Given the operation will be carried on inside a building that is to be demolished,

clearance air sampling will not be conducted upon the completion of abatement. Following abatement

and final cleaning, the building shall not be re-entered by any person except the workers involved in the

building demolition. Following the cleaning phase of the project, if entry is required for any reason

including emergency purposes, proper PPE consistent with Type 3 asbestos operations shall be worn by

every person entering the building.

Given the operation will be carried on inside a building that is to be demolished, construction of interior

containment(s) is not required. The building perimeter walls will act as the enclosure. An internal or

remote decontamination facility for workers and tools is permitted.

Contractor is to supply construction grade lighting for execution of project.

Contractor shall supply temporary electrical power distribution systems (i.e. power distribution panel)

for tools and equipment needed for project. Power to the building will be supplied but internally the

building is to be de-energized and temporary electrical power is to be installed by a qualified electrical

contractor and shall include ground fault circuit interrupters.

The following statements in this section do not supplant or replace

the requirements stated in:

Ontario Regulation 278/05 (as amended)

� Guideline - Silica on Construction Projects

Measures and procedures stated within the regulations and guidelines listed above are to be

followed for project


Scope of Work for the Removal of Identified Designated Substances

City of Niagara Falls6121 Lundy’s Lane, Niagara Falls, ON

GENERAL MEASURES AND PROCEEDURES FOR PROJECT – ASBESTOS, MERCURY AND SILICA:

Prior to abatement commencement, warning signs restricting access to the building must be posted in

sufficient numbers in the work area(s) indicating the hazardous material of concern and personal

protective equipment to be worn inside the work area(s).

Doorways, windows, vents, floor drains and services holes in walls and grilles located within the work

area(s) must be sealed with polyethylene sheeting sealed with tape as appropriate.

Washing facilities for decontamination consisting of wash basin, water, soap and towels should be

provided to workers for all phases of the project.

Workers should not eat, drink, chew gum or smoke in the work area(s).

Drop sheets should be used below the abatement activities in work area(s) where dust, chips or debris

containing designated substances are produced or may be produced.

Dust and waste should be cleaned up regularly and removed by vacuuming with a HEPA filter equipped

vacuum.

Compressed air or dry sweeping should not be used to clean up any dust or waste from the work area(s)

or from clothing.

Gross waste and debris is to be cleaned up at the end of each abatement shift for prevention and

housekeeping measures.

Inspection of the work area(s) is to be conducted daily to ensure the work area(s) are clean and controls

for construction are maintained.

Waste containers used to dispose of designated substances shall be dust tight, suitable for the type of

waste, impervious to the waste intended for and clearly identified.

Waste containers shall be cleaned with a damp cloth or HEPA vacuumed immediately before being

removed from the work area(s) and removed from the work area(s) frequently and at regular intervals.

SPECIFIC MEASURES AND PROCEEDURES FOR PROJECT - ASBESTOS ABATEMENT:

Water with a wetting agent added shall be used to control the spread of dust and fibres during the

removal of the asbestos-containing materials.

Each side of each entrance or exit from the work area(s) must be fitted with curtains constructed of

polyethylene sheeting.

A decontamination facility, as described in O. Reg. 278/05 (as amended) shall be located as close as

practicable to the work area(s). The facility should consist of three rooms arranged in sequence and

constructed so as to prevent the spread of asbestos-containing dust. The rooms shall be separated with

curtains of polyethylene sheeting fitted to each side of the entrance or exit to each room. Each worker

shall enter the facility when leaving the work area(s) and decontaminate his or herself in the order as

outline in O. Reg. 278/05 (as amended).


Scope of Work for the Removal of Identified Designated Substances

City of Niagara Falls6121 Lundy’s Lane, Niagara Falls, ON

PERSONAL PROTECTIVE EQUIPMENT AND RESPIRATORY PROTECTION - ASBESTOS ABATEMENT:

Protective clothing shall be provided by the employer and worn by every worker who enters the work

area(s). The protective clothing shall:

1. Be made of material that does not readily retain nor permit penetration of asbestos fibres

2. Consist of head covering and full body covering that fits snugly at the ankles, wrists and neck, in

order to prevent asbestos fibres from reaching the garments and skin under the protective

clothing

3. Include suitable footwear

4. Be repaired or replaced if torn

The employer shall provide every worker who will enter the work area(s) with a NIOSH approved

respirator in accordance with the general requirements for respirators outlined in Section 13 and Table

2 of O. Reg. 278/05 (as amended) and the worker shall wear and use the respirator.

SPECIFIC MEASURES AND PROCEEDURES FOR PROJECT - SILICA ABATEMENT:

The generation of silica-containing airborne dust should be controlled by thoroughly wetting the area

prior to and during the drilling or cutting operations and during the loading, scraping or moving.

PERSONAL PROTECTIVE EQUIPMENT AND RESPIRATORY PROTECTION - SILICA ABATEMENT:

A NIOSH approved respirator for Type 2 silica operations in accordance with respirator requirements as

outlined in Table 1: Respirator Requirement of Guideline – Silica on Construction Projects.

WASTE TRANSPORT AND DISPOSAL

Conform to requirements outlined in Ontario Regulation 347 – General – Waste Management (as

amended) for waste management, transporting and disposal of hazardous waste.

Ensure shipment of containers to dump is taken by waste hauler licensed to transport hazardous waste.

Retain receipt of disposal and submit to owner as proof of disposal.

PROJECT CLOSEOUT

Polyethylene sheeting, seals, tape, cleaning material, clothing, and other contaminated waste is to be

disposed of in waste containers suitable for the type of waste, impervious to the waste intended for and

clearly identified and included for hazardous waste.

The contractor is to conduct a final visual inspection of the work area(s) to ensure all types of dust or

debris is not visually evident.

More magazines by this user