Photometrics<br />

Coefficients of Utilization<br />

Effective floor cavity reflectance 20%<br />

rc 80% 50% 30%<br />

rw 70 50 30 10 50 30 10 50 30 10<br />

RCR<br />

0<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

ECT-332-W-EB81<br />

Electronic Ballast<br />

(3) FO32/841 lamps 2850 lumens<br />

Spacing criterion: (II) 1 3 x mounting<br />

height, (⊥) 1 4 x mounting height<br />

Efficiency 88 1%<br />

Test Report: ECT332WEB81<br />

Installation<br />

System Performance<br />

Energy<br />

Savings<br />

% Light<br />

Gain/Loss<br />

Part<br />

Number<br />

System Performance Table<br />

105 105 105 105 98 98 98 94 94 94<br />

95 91 87 84 85 82 80 82 79 77<br />

86 79 73 67 74 69 65 71 67 63<br />

78 69 61 55 65 59 54 62 57 53<br />

72 61 53 47 57 51 46 55 50 45<br />

66 54 46 40 51 44 39 49 43 39<br />

61 48 40 35 46 39 34 45 38 34<br />

56 44 36 30 42 35 30 40 34 30<br />

52 40 32 27 38 31 27 37 31 27<br />

49 37 29 24 35 29 24 34 28 24<br />

46 34 27 22 32 26 22 32 26 22<br />

Zonal Lumen Summary<br />

Zone Lumens %Lamp %Fixture<br />

0-30<br />

0-40<br />

0-60<br />

0-90<br />

0-180<br />

Troffer ECOFIT<br />

3 LAMP T12 4 LAMP T12 3 LAMP T12 4 LAMP T12<br />

44%<br />

37%<br />

54%<br />

3%<br />

ECT-232-M-EB81/PLUS<br />

1907 22 3 25 3<br />

3152 36 9 41 8<br />

5753 67 3 76 4<br />

7534 88 1 100 0<br />

7534 88 1 100 0<br />

All components (reflectors, socket brackets, sockets, screws, and wire<br />

nuts) are included in each kit for installation and require only a few<br />

basic tools for assembly.<br />

44%<br />

34%<br />

-1%<br />

54%<br />

ECT-232-W-EB81/PLUS<br />

% light gain/light loss utilize S/P adjusted lumens.<br />

3 LAMP T12 4 LAMP T12 3 LAMP T12 4 LAMP T12<br />

55%<br />

17% -27%<br />

ECT-232-M-EB82<br />

64%<br />

Coefficients of Utilization<br />

Effective floor cavity reflectance 20%<br />

rc 80% 50% 30%<br />

rw<br />

RCR<br />

70 50 30 10 50 30 10 50 30 10<br />

0<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

ECT-232-M-EB81<br />

Electronic Ballast<br />

(2) 32W T8 F32T8/TL841 lamps 3050 lumens<br />

Spacing criterion: (II) 1 2 x mounting<br />

height, (⊥) 1 1 x mounting height<br />

Efficiency 88%<br />

Test Report: ECT232MEB81<br />

105 105 105 105 98 98 98 94 94 94<br />

97 93 89 86 87 85 82 84 82 80<br />

89 82 77 73 78 74 70 75 71 68<br />

82 74 67 62 70 65 60 67 63 59<br />

76 66 59 54 63 57 53 61 56 52<br />

70 60 52 47 57 51 46 55 50 46<br />

65 54 47 42 52 46 41 51 45 41<br />

61 50 42 37 48 41 37 46 41 37<br />

57 46 39 34 55 45 38 34 37 33<br />

53 42 35 31 41 35 30 40 34 30<br />

50 39 32 28 38 32 28 37 32 28<br />

Zonal Lumen Summary<br />

Zone Lumens %Lamp %Fixture<br />

0-30 1896 31 1 35 3<br />

0-40 2988 49 0 55 7<br />

0-60 4632 75 9 86 3<br />

0-90 5366 88 0 100 0<br />

0-180 5366 88 0 100 0<br />

Reflector Dimensions<br />

9-3/4" [248mm]<br />

19-13/16"<br />

[505mm]<br />

Cost of<br />

1000 S/P<br />

Adj Lmns<br />

4000 hrs<br />

FOOTNOTES: 1 Lumen maintenance is based on lamp manufacturer's stated data 2 Design System Lumens is the fixture lumens at 40% of rated lamp life and is calculated as Quantity of Lamps x Lamp Lumens x<br />

Lumen Maintenance x Fixture Efficiency x Ballast Factor 3 S/P Ratio is the lamp manufacturers stated Scotopic/Photopic Ratio; accepted by some lighting designers to adjust for the relative strengths of scotopic<br />

and photopic vision, not yet adopted by IESNA 4 S/P Adjusted Lumens calculates the brightness perception scotopic/photopic ratio as Design System Lumens x (S/P)^ 0 5 based on 4100K lamps 5 ECT-232-M-EB8/PLUS 2 3100 94% 88% 1.15 5898 1.95 1.68 8236 73<br />

$0.08 kWh<br />

$2.80 114<br />

ECT-232-W-EB8/PLUS 2 3100 94% 85% 1.15 5683 1.95 1.68 7937 73 $3.02 106<br />

ECT-232-M-EB81 2 3100 94% 88% 0.88 4513 1.95 1.68 6302 58 $3.80 84<br />

ECT-232-W-EB81<br />

Comparison System<br />

2 3100 94% 85% 0.88 4349 1.95 1.68 6073 58 $4.10 78<br />

3L T12 Parabolic 3 2750 88% 65% 0.90 4247 1.50 1.22 5202 130 $13.67 23<br />

4L T12 Troffer 4 2750 88% 75% 0.90 6534 1.50 1.22 8002 160 $9.48 34<br />

LER (Luminaire<br />

Efficiency Ratio) is an accepted method of comparing fixture performance<br />

55%<br />

14% -32%<br />

ECT-232-W-EB82<br />

64%<br />

Design S/P<br />

No of Lamp Lumen Fixture Ballast System S/P Brightness Adjusted<br />

Troffer Ecofit Comparison Lamps Lumens Maintenance 1 Efficiency Factor Lumens 2 Ratio 3 Perception Lumens 4 Wattage LER 5<br />

X<br />

X=1-7/8"<br />

[48mm]<br />

34