Bedienungsanleitung, Manuel, Manual, Manuale, 9113, PR ...

mts.ch

Bedienungsanleitung, Manuel, Manual, Manuale, 9113, PR ...

Protection degree ........................................ IP20

Weight ......................................................... 250 g / 265 g with 4501

Isolation:

Input to any ................................................. 300 VAC double / reinforced isolation

Analogue output to supply .......................... 300 VAC double/reinforced isolation

Status relay to supply ................................. 150 VAC double/reinforced or

300 VAC basic isolation

RTD input:

Input

type

Pt100

Ni100

Input for RTD types:

Pt10*, Pt20*, Pt50*, Pt100, Pt200, Pt250, Pt300, Pt400, Pt500, Pt1000

Ni50, Ni100, Ni120, Ni1000

Cable resistance per wire (max.) ................. 50 Ω

Sensor current ............................................. Nom. 0.2 mA

Effect of sensor cable resistance

(3- / 4-wire) .................................................. < 0.002 Ω / Ω

Sensor error detection ................................ Programmable ON / OFF

Sensor error current:

when detecting ........................................ < 2 µA

else......................................................... 0 µA

* No short circuit detection for Pt10, Pt20 and Pt50

TC input:

Type

B

E

J

K

L

N

R

S

T

U

W3

W5

LR

Min.

value

-200°C

-60°C

Min.

value

+0°C

-100°C

-100°C

-180°C

-200°C

-180°C

-50°C

-50°C

-200°C

-200°C

0°C

0°C

-200°C

Max.

value

+850°C

+250°C

Max.

value

+1820°C

+1000°C

+1200°C

+1372°C

+900°C

+1300°C

+1760°C

+1760°C

+400°C

+600°C

+2300°C

+2300°C

+800°C

Standard

IEC60751

DIN 43760

Standard

IEC 60584-1

IEC 60584-1

IEC 60584-1

IEC 60584-1

DIN 43710

IEC 60584-1

IEC 60584-1

IEC 60584-1

IEC 60584-1

DIN 43710

ASTM E988-90

ASTM E988-90

GOST 3044-84

9113 - Product Version 9113-002 35