Preparing the lancing device for obtainingnew blood sample: load new lancetWhen all 6 lancets have been used:remove lancet drumChanging an empty cassette2121Push lever to right and back again1 Remove cap 2 Pull out drum 1 Open tip cover 2 Release cassettecompartment cover3 Open cassettecompartment cover4 Remove emptycassetteCLICK5 Insert new cassette 6 Close cassette 7 Press cover to close 8 Press button 9 Press button 10 Press button 11 Main menu is 12 Close tip covercompartment coverdisplayedFunctions of the buttonsTurning meter on or offExecuting a commandCounting downwardsMoving down a menuCounting upwardsMoving up a menupress and hold longer than2 secondsPressbuttonPressbuttonPressbuttonPressbuttonPressbuttonPressbuttonAdjust settingspress and holdlonger than 2 seconds1 Turn on meter 2 Wait for displays 3 Main menu is displayed 4 Select Settings5 Open SettingsSettings menu overviewOverview of the meter19487562 310 111213141 Battery compartment cover (right: from above; farright: open)2 Infrared window3 Batteries [1.5 V, type AAA, alkaline-manganese orhigh energy batteries (2 batteries required)]4 Lancing device (docked)5 Tip cover (bottom: open)6 Test area (at the tip of the cassette ready for a test)– this is where you apply the blood7 Down/Up buttons8 On/Off and Enter button9 Display10 Release button for undocking the lancing device11 Type plate12 Release button for opening the cassette compartmentcover13 Cassette compartment cover (right: open)14 Test cassette (in place in the meter)Overview of the lancing device202122181917161515 Multifunction button (priming and lancing)16 Lever for rotating the lancet drum and loading a newlancet17 Lancet drum containing 6 lancets18 Numbers indicating penetration depth settings19 Rotatable cap (rotating the cap on the device setsthe penetration depth)20 Pin-hole opening for lancet21 Penetration depth indicator22 Window showing number of available lancetsMenu overviewMain menuTest Turn off Memory SettingsResultSet flag All results Time/Date Tones Reminders Target range VolumeControl test Color Averages Time Beeper New Turn onTurn offGeneral OnOff All results 7 days Date Reminders Edit Change BrightnessBefore meal OnOff Before meal 14 days Time format Acoust. mode In 1 hour Turn onTurn off CancelAfter meal OnOff After meal 30 days In 2 hours Change LanguageReminder Reminders Transfer data In 3 hours DeleteFor analysisCancelDisplay formatTable to PCSingle valueMain menuToolsSelect withListOpen or set withDisplay check Validity Clean Change cass.This <strong>Quick</strong> <strong>Reference</strong> <strong>Guide</strong> is not a substitute for the full User’s Manual supplied with your<strong>Accu</strong>-<strong>Chek</strong> Mobile blood glucose meter.Please be sure to observe the safety information in the User’s Manual.