The first digit of the display (see fig. 7 on page 5, Pos. 5) shows the<br />
menu level and the second and third show the parameter which can<br />
be set.<br />
Press the + button (see fig. 7 on page 5, 6) once to switch to menu level<br />
2.<br />
Press the operating mode button (see fig. 7 on page 5, Pos. 4) to<br />
change the parameter.<br />
The digits in the display flash until the parameter you enter is confirmed.<br />
Press the + or - buttons (see fig. 7 on page 5, Pos. 6 and 7) to select<br />
the value for the low voltage cut-off. The ID number displayed in the<br />
second and third place of the digital display stands for the voltage at<br />
which the system is switched off.<br />
ID<br />
number<br />
Low-voltage<br />
cut-off<br />
ID<br />
number<br />
Low-voltage<br />
cut-off<br />
1 23,2 6 23,7<br />
2 23,3 7 23,8<br />
3 23,4 8 23,9<br />
4 23,5 9 24,0<br />
5 23,6 10 24,1<br />
➤<br />
✓<br />
✓<br />
Press the operating mode button (see fig. 7 on page 5, Pos. 4) to<br />
confirm your entry.<br />
The set value is saved and is then used when the system is restarted.<br />
You are now in menu level 2 and can use the + and - buttons to switch<br />
between menu levels.<br />
6.3.4 Menu level 3: Operating mode<br />
The system always starts with a defined operating mode for room temperature.<br />
This parameter can be configured:<br />
➤<br />
✓<br />
➤<br />
➤<br />
✓<br />
Start configuration mode (see chapter "Start and end configuration<br />
mode" on page 30).<br />
The first digit of the display (see fig. 7 on page 5, Pos. 5) shows the<br />
menu level and the second and third show the parameter which can<br />
be set.<br />
Press the + button (see fig. 7 on page 5, 6) twice to switch to menu level<br />
3.<br />
Press the operating mode button (see fig. 7 on page 5, Pos. 4) to<br />
change the parameter.<br />
The digits in the display flash until the parameter you enter is confirmed.<br />
32