Allocation of clamps1.3.3 Allocation of clamps for system 3Solar system and after-heating with 1 store, 3 sensorsand 2 pumps (for solar heating and after-heating).The sensor S4/TRF can optionally be used for heatquantity balancing.ARR 3SymbolSpecificationS1S2Collector sensorStore sensor lowerS1S3Store sensor atthe topS4/TRFSensor for heatquantity balancing(optionally)R1S3R1R2Solar pumpPump for heatexchangeS4/TRFS2R21.3.4 Allocation of clamps for system 4Solar system and store charge in layers with 1 store,3 sensors, 1 solar pump and 1 3-way-valve for storecharge in layers. The sensor S4/TRF can optionally beused for heat quantity balancing.ARR 4SymbolSpecificationS1S2Collector sensorStore sensor lowerS1S3Store sensor atthe topS4/TRFR1R2Sensor for heatquantity balancing(optionally)Solar pump3-way-valveR1S4/TRFR2S3S238 VELUX