Technische Informationen / Technical information

The Netherlands

The Netherlands Lead-free XLPE/PVC-sheathed cable KEMA KEUR approved D Application Power cable for industrial and wiring purposes. Used in the open, in dry, damp and wet environments in the open and concealed, as well as in masonry and in cable conduits and trays. Outdoor usage is only possible, as long as the cable is protected against direct sunlight. National regulations for electrical installation (NEN 1010) must be followed. The product corresponds to the directive 2014/35/EU (low voltage directive). Construction Copper conductor plain, solid or stranded Insulation XLPE acc. to K 42 C-1-4-D and K 42 C-1-11-D Technical data CPR performance class Dca acc. to EN 50575 Nominal voltage 600 / 1000 V Test voltage 3.500 V Insulation resistance 20 M x km Temperature range Min. bending radius category C Marking of outer sheath, example: 1306 KEMA KEUR YMvK 3 G 2.5 0,6/1 kV CE + meter marking + XBK-KABEL

XBK-Energy Denmark Lead-free PVC-sheathed cable Application For industrial and wiring purposes. Used in the open, in dry, damp and wet environments in the open and concealed, as well as in masonry and in concrete, not suitable for direct usage is only possible, as long as the cable is protected against direct sunlight. National regulations for electrical installation must be followed. The product corresponds to the directive 2014/35/EU (low voltage directive). Construction Copper conductor plain, solid or stranded Insulation PVC Sheath special PVC, light grey,similar to DEMKO Technical data CPR performance class Eca acc. to EN 50575 Nominal voltage 300 / 500 V Test voltage 2.000 V Insulation resistance >20 M x km Temperature range Min. bending radius Marking of outer sheath, example: DK-05VV-U 3 G 1,5 300/500 V CE BLYFRI + metermarking + production code + CPR marking. Please note: We have also the 450/750 V version DK-07VV-U/R and the steel tape armoured version X07VZ4V-U/R in our delivery programme. Please request. XBK-KABEL

Publikationen Deutsch

Produktkatalog/Product catalogue 2019/2020
Hannover Messe 2019
GLOBALFLEX®-deutsch
Produkt- und Lieferübersicht
Ihre gute Verbindung
GLOBALFLEX® - Eine Steuerleitung für die ganze Welt!
Höchste Sicherheit für Mensch und Gebäude
Hybrid-Leitungen
Koaxiale Signalkabel

Copyright © 2017 XBK-KABEL Xaver Bechtold GmbH