12.07.2015 Views

Koblingsskjema Wiring diagram Kopplingsschema ... - Elko AS

Koblingsskjema Wiring diagram Kopplingsschema ... - Elko AS

Koblingsskjema Wiring diagram Kopplingsschema ... - Elko AS

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Koblingsskjema</strong><strong>Wiring</strong> <strong>diagram</strong><strong>Kopplingsschema</strong>KytkentäohjeNB0102007.05.14.Rev.3.2MPTMonteringsanvisningInstallation guideAsennusohjeEIA/TIA 568B12345678ParPairNorskFargeEnglishColourSvenskFärgSuomiVäritPINNo.1 Hvit/BlåBlå2 Hvit/OransjeOransjeWhite/BlueBlueWhite/OrangeOrangeVit/BlåBlåVit/OrangeOrangeValk/SininenSininenValk/OranssiOranssi541219” Modular Patch Panels Kat-5 / Kat-610” Mini Patch Panel Kat-5 / Kat-63 Hvit/GrønnGrønn4 Hvit/BrunBrunWhite/GreenGreenWhite/BrownBrownVit/GrönGrönVit/BrunBrunValk/VihreäVihreäValk/RuskeaRuskea367819” Modular Patch Panels Cat-5 / Cat-610” Mini Patch Panel Cat-5 / Cat-6EIA/TIA 568A1234567819” Ristikytkentäpanelit Cat-5 / Cat-610” Ristikytkentäpanelit Cat-5 / Cat-6ParPairNorskFargeEnglishColourSvenskFärgSuomiVäritPINNo.1 Hvit/BlåBlåWhite/BlueBlueVit/BlåBlåValk/SininenSininen542 Hvit/GrønnGrønnWhite/GreenGreenVit/GrönGrönValk/VihreäVihreä123 Hvit/OransjeOransjeWhite/OrangeOrangeVit/OrangeOrangeValk/OranssiOranssi364 Hvit/BrunBrunWhite/BrownBrownVit/BrunBrunValk/RuskeaRuskea78www.elko.noELKO <strong>AS</strong>, Postboks 234, 1301 Sandvika, Tlf: +(47) 67 80 73 00 Faks:+ (47) 67 80 73 01ELKO AB, Box 47020, 100 74 Stockholm, Tel. +(46)08 449 27 00, Fax. +(46) 08 449 27 30ELKO SUOMI OY Olarinluoma 16 02200 ESPOO Tel:+(358) 09 4393210 Fax: +(358) 09 43932120www.elko.noELKO <strong>AS</strong>, Postboks 234, 1301 Sandvika, Tlf: +(47) 67 80 73 00 Faks: +(47) 67 80 73 01ELKO AB, Box 47020, 100 74 Stockholm, Tel. +(46)08 449 27 00, Fax. +(46) 08 449 27 30ELKO SUOMI OY Olarinluoma 16 02200 ESPOO Tel:+(358) 09 4393210 Fax: +(358) 09 43932120


Fig. 1PIMFFTPS-FTPUTPFig. 2 Fig. 3Norsk English Svensk SuomiFig. 1: Forberede kabelenFig. 1: Preparing the cableFig. 1: Förbered kabelnKuva 1: Kaapelin käsittelyAlle kabelyperFjern ytterkappen på kabelen minimum 60 mm.PIMF og S-FTP kablerRett ut og skill flettingen fra parene.Tvinn flettingen tett rundt enden av ytterkappen.Kutt den synlige folien rundt hvert par (PIMF)eller den felles folien (S-FTP) rett ved enden avytterkappen.FTP kablerTvinn jord-tråden tett rundt den synlige folien rettved enden av ytterkappen.Fig. 2: TermineringPlasser de ferdig forberedte kablene under skjermklemmenpå panelet.Ved skjermede kabler er det viktig at den synligedelen av den flettede kabelskjermen blir liggendeunder skjermklemmen.Skru til fingermutteren med fingrene.Plasser de enkelte lederne på rett plass i LSAPlus knivkontaktene. Følg fargekoden på knivkontaktenenøye.Sjekk at ingen par er tvunnet opp mer enn 13 mm.Terminer parene med et Krone LSA Plus verktøy.Fig. 3Bruk kabelstrips til å strekkavlaste kablene bakerstpå panelet. Ved paneler for skjermede kabler måskjermlokket settes på til slutt.All cable typesRemove the outer jacket of the cables by minimum60 mm.PIMF and S-FTP cablesStraighten and separate the braid from the pairs.Twist the braid firmly around the end of the outerjacket.Cut the foils around the individual pairs (PIMF), orcut the common foil (S-FTP) close to the end of theouter jacket.FTP cablesTwist the exposed drain wire tightly around theexposed foil close to the end of the outer jacket.Fig. 2: Cable terminationPlace the prepared cables under the screen clamp.By screened cables, place the exposed and preparedscreen under the clampTighten the finger screw.Place the individual wires in correct positions on theLSA plus IDC. Follow the color coding on the LSAPlus.. Make sure that each individual pair has notbeen untwisted more than 13 mm.Terminate the pairs using a Krone LSA Plus tool.Fig. 3Use cable strips to strain relief the cables at the rearend of the panel By panels for screened cables, puton the panel screen cover.För alla kabeltyperTa bort yttermanteln på kabeln minimum 60 mm.PIMF och S-FTP kablarRäta ut och skilj flätningen från paren.Tvinna flätningen runt änden av manteln.Ta bort den synliga folien runt varje par (PIMF) ellerden gemensamma folien (S-FTP) vid änden avmanteln.FTP kablerTvinna jordtråden runt den synliga folien vid ändenav manteln.Fig. 2: KontakteringPlacera de preparerade kablarna under skärmklämmanpå panelen.Med skärmade kablar är det viktigt att den synligadelen av den flätade kabelskärmen kommer underskärmklämman.Skruva till muttern med fingrarna.Placera ledarna i LSA+ kontakterna och följ färgkoden.Maximal upptvinning av ledarna i varje par är 13mm.Kontaktera paren med ett Krone LSA Plus verktyg.Fig. 3Använd buntband till att få ordning på kablarna ibakkant på panelen. Med paneler för skärmadekablar måste skärmlocket användas.Kaikki kaapelityypitKuori kaapelin ulkovaippaa vähintään 60 mmPIMF ja S-FTP tyyppiset kaapelitSuorista ja irroita suojavaippa johtimista.Käännä suojavaippa tiukasti kaapelin ulkovaipanympäri.Katkaise folio yksittäisten parien ympäriltä(PIMF), tai katkaise suojafolio (S-FTP) läheltäkaapelin ulkovaippaa.FTP-kaapelitKäännä sekä suojafolio että punattu suoja tiukastikaapelin ulkovaipan ympäri.Kuva. 2: Kaapelin päättäminenLaita kaapelin ulkovaippa vedonpoistimen alle,Suojatuissa kaapeleissa varmista että suojafoliosekä punottu suoja ovat vedonpoistimen allaKiristä vedonpoistimen.Sijoita yksittäiset johtimet oikeille paikoilleenLSA-rimalle. Katso värikoodit sivulta 1. Varmistaettä minkään yksittäisen parin parikierrettä eiavattu enempää kuin 13mm (Cat5e) ja n.6mm(Cat6). Kiinnitä kaapelit hahloihinsa LSA PLUstyökalulla.Kuva 3:Käytä nippusidettä kiinnittääksesi kaapelipaneelin takaosaan. Suojatussa mallissaasenna suojkansi myös paikoilleen.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!