3002240 - ESL-125AE - 2011-12-21 / 125115<br />
UK<br />
DESCRIPTION<br />
The ESL120AE is a mo<strong>de</strong>rn integrated cooker hood for fitting<br />
in top cabinets or stainless steel cooker canopies, for example.<br />
The cooker hood features a built-in control panel on the front.<br />
The ESL120AE can be used for central ventilation systems.<br />
It has a built-in motor-controlled damper that can be adjusted<br />
for basic or forced ventilation.<br />
The damper is activated through the control panel and the<br />
“forced ventilation” indicator lamp lights up. The damper<br />
automatically returns to basic ventilation after max. 60 minutes.<br />
INSTALLATION<br />
The ducting of exhaust air must be carried out in accordance<br />
with the applicable regulations from the relevant authority.<br />
The exhaust air must not be connected to any duct that is<br />
used to extract flue gases from any equipment fuelled by<br />
energy other than electricity such as gas or oil fires, stoves<br />
and the like.<br />
FITTING, fig. 2.<br />
The distance between the cooker and the hood must be at<br />
least 45 cm. For gas cookers, the distance increases to 65<br />
cm. If a higher installation height is recommen<strong>de</strong>d by the gas<br />
cooker's manufacturer, this should be respected.<br />
Cut a hole measuring 298 x 451 mm in the base of the top<br />
cabinet. Use the screws provi<strong>de</strong>d to fit the cooker hood. Then<br />
fit the appropriate length of spiro duct. Affix it tightly and<br />
appropriately to the cooker hood spigot.<br />
Electrical installation, fig 3.<br />
The coocker hood is <strong>de</strong>livered with wire and earth plug for<br />
connection to earth wall socket, 230 V<br />
An adaptor is mounted on the plug. When used in other<br />
countries but Denmark the adaptor is removed before the<br />
coocker hood is connected to mains supply - fig. 3.<br />
Initial adjustment of the airflow<br />
On <strong>de</strong>livery, the damper in the cooker hood is set to:<br />
Basic ventilation 20 l/s (72 m³/h) at 120 Pa<br />
Damper setting B 3,7<br />
Noise pressure level = 27 dB(A)<br />
Forced ventilation 40 l/s (144 m³/h) at 100 Pa<br />
Damper setting A 3.8<br />
Noise pressure level = 32 dB(A)<br />
To fine tune the airflow settings, follow the instructions in the<br />
section entitled “Damper settings”.<br />
19/24<br />
8,5<br />
50<br />
320<br />
30<br />
50<br />
18,5<br />
User instructions<br />
Ø 125<br />
442<br />
221<br />
93<br />
120 40<br />
86<br />
292<br />
8 R 7<br />
480<br />
450/650<br />
1<br />
2<br />
3