Modeller:<br />

AWM-GW<br />

RCM-DW<br />

ACK-CW/AW<br />

ACC-CW<br />

Fläktkonvektorer<br />

ahlsell kyl<br />

DS108:0806


INNEHÅLLSFÖRTECKNING<br />

1. Egenskaper.............................................................3,6,9,13<br />

2. Tekniska data...............................................................4-17<br />

3. Elektrisk data...............................................................18-21<br />

4. Komponentdata...........................................................22-27<br />

5. Dimensioner................................................................28-39<br />

6. Elschema.....................................................................40-44<br />

7. Inst<strong>alla</strong>tion...................................................................45-60<br />

8. Fjärrkontroll.................................................................61-73<br />

2


1. AWM - EGENSKAPER<br />

• ENKEL INSTALLATION<br />

- Beroende på det smala och kompakta utförandet samt enheternas låga vikt är inomhusdelen lätt<br />

att placera och installera i olika miljöer.<br />

• PLATSBESPARANDE<br />

- Inomhusdelarna monteras på vägg och tar inte upp någon golv- eller takyta. Väggmontaget är en<br />

fördel speciellt vid låga takhöjder.<br />

• LÅG LJUDNIVÅ<br />

- Inomhusdelen har en radialfläkt, och det sköna klimatet förstärks av fläktens låga ljudnivå.<br />

• FÖRNÄMLIG LUFTDISTRIBUTION<br />

- Enheterna har ett bra luftflöde och en förnämlig distribution i fyra riktningar av den kylda luften.<br />

Luftdistributionen kan antingen ställas in manuellt eller med automatik via fjärrkontrollen.<br />

• SERVICEVÄNLIGT UTFÖRANDE<br />

- Inomhusdelens luftfilter har en ny design som gör det enkelt att vid rengöring dra ut filtret från enhetens<br />

intagsgaller.<br />

- Frontpanelen kan enkelt tas bort varvid elektriska komponenter, kablage och rörledningar sedan<br />

blir lätt tillgängliga för service och underhåll.<br />

• TRÅDLÖS FJÄRRKONTROLL<br />

- Med den trådlösa fjärrkontrollen är det möjligt att att var som helst i rummet styra och ställa in aggregatets<br />

drift. Fjärrkontrollens räckvidd är nio meter, och den har bland annat följande funktioner:<br />

- Fläkten i inomhusdelen kan ställas in på hög/medium/låg eller automatik.<br />

- Nattfunktion med högre rumstemperatur under natten, vilket betyder att ett rum inte kyls ner i onödan<br />

om det inte används nattetid.<br />

- Luftdistributionen kan ställas in för automatisk funktion.<br />

- Rumstemperaturen regleras av en elektronisk termostat.<br />

- En timerfunktion som kan ställas in att starta/stoppa aggregatet med upp till 15 timmars fördröjning.<br />

3


AWM-GW<br />

2. TEKNISK DATA<br />

AWM07GW AWM10GW AWM15GW<br />

Btu/h 8000 9500 11000<br />

W 2340 2780 3220<br />

Btu/h 5920 6935 8030<br />

W 1732 2029 2351<br />

Btu/h 18000 21600 24200<br />

W 5280 6330 7090<br />

HIGH l/s / CFM 130 / 275 142 / 300 163 / 345<br />

MEDIUM l/s / CFM 106 / 225 118 / 250 135 / 285<br />

LOW l/s / CFM 83 / 175 94 / 200 104 / 220<br />

HEIGHT mm/in 260 / 10.2<br />

WIDTH mm/in 799 / 31.5<br />

DEPTH mm/in 198 / 7.8<br />

HEIGHT mm/in 337 / 13.3<br />

WIDTH mm/in 857 / 33.7<br />

DEPTH mm/in 270 / 10.6<br />

kg/lb 10 / 22.1<br />

dBA 40 / 35 / 29 39 / 34 / 28 42 / 36 / 29<br />

USGPM<br />

LITRES/M<br />

1.85<br />

7.00<br />

2.11<br />

8.00<br />

2.38<br />

9.00<br />

kPa / psi 41 / 5.9 54 / 7.8 67 / 9.7<br />

kPa / psi 37 / 5.4 44 / 6.4 59 / 8.6<br />

kPa / psi<br />

m/s<br />

ft/min<br />

0.65<br />

127.3<br />

0.61<br />

119.2<br />

0.70<br />

137.1<br />

cm 3 MODEL<br />

NOMINAL TOTAL COOLING CAPACITY<br />

NOMINAL SENSIBLE COOLING CAPACITY<br />

NOMINAL TOTAL HEATING CAPACITY (ENTERING<br />

WATER TEMP. = 70°C)<br />

NOMINAL AIR FLOW<br />

260 / 10.2<br />

UNIT DIMENSION<br />

899 / 35.4<br />

198 / 7.8<br />

337 / 13.3<br />

PACKING DIMENSION<br />

957 / 37.7<br />

270 / 10.6<br />

UNIT WEIGHT<br />

12 / 26.5<br />

SOUND PRESSURE LEVEL ( H/M/L )<br />

NOMINAL WATER FLOW RATE<br />

HEAD LOSS (COOLING)<br />

HEAD LOSS (HEATING) : 70°C<br />

MAX. WORKING PRESSURE<br />

1608 / 233<br />

SURFACE AIR VELOCITY<br />

FAN COIL WATER VOLUME & MASS<br />

/ kg 653 / 6.5 737 / 7.4 737 / 7.4<br />

CONNECTION 1/2" BSP FEMALE ADAPTOR<br />

CONTROL<br />

CONDENSATE DRAIN SIZE<br />

ROOM TEMPERATURE<br />

AIR DISCHARGE<br />

OPERATION<br />

mm/in<br />

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.<br />

2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 & ISO13253.<br />

3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :<br />

a) COOLING - ENTERING AIR TEMP. : 27°C (80.6°F) DB / 19°C (66.2°F) WB, ENTERING WATER TEMP. : 7°C (44.6°F), LEAVING WATER TEMP. : 12°C (53.6°F)<br />

b) HEATING - ENTERING AIR TEMP.: 20°C (68°F) DB, ENTERING WATER TEMP. : 70°C (158°F), LEAVING WATER TEMP. : 65°C (149°F)<br />

4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS C 9612 STANDARD. MWMFW : POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 0.8m BELOW THE<br />

UNIT. MWM301W : 1m IN FRONT AND 1 m BELOW THE DISCHARGE OPENING OF THE UNIT (JIS B 8615)<br />

4<br />

MICRO-COMPUTER CONTROLLED THERMOSTAT<br />

AUTOMATIC LOUVER (UP& DOWN)<br />

LCD WIRELESS MICRO-COMPUTER REMOTE CONTROL<br />

16 / 0.63


AWM-GW<br />

AWM20GW AWM25GW<br />

Btu/h<br />

W<br />

16500<br />

4840<br />

18000<br />

5270<br />

Btu/h<br />

W<br />

13120<br />

3848<br />

14760<br />

4326<br />

Btu/h 35000 40500<br />

W 10260 11870<br />

HIGH l/s / CFM 297 / 630 312 / 660<br />

MEDIUM l/s / CFM 231 / 490 274 / 580<br />

LOW l/s / CFM 208 / 440 222 / 470<br />

HEIGHT mm/in<br />

WIDTH mm/in<br />

DEPTH mm/in<br />

HEIGHT mm/in<br />

WIDTH mm/in<br />

DEPTH mm/in<br />

kg/lb 16 / 35.3 16 / 35.3<br />

dBA 49 / 43 / 40 50 / 48 / 44<br />

USGPM<br />

LITRES/M<br />

3.52<br />

13.33<br />

3.65<br />

13.83<br />

kPa / psi 37 / 5.4 41 / 5.9<br />

kPa / psi 31 / 4.5 33 / 4.8<br />

kPa / psi<br />

m/s 1.10 1.16<br />

ft/min 217.2 228.0<br />

cm 3 MODEL<br />

NOMINAL TOTAL COOLING CAPACITY<br />

NOMINAL SENSIBLE COOLING CAPACITY<br />

NOMINAL TOTAL HEATING CAPACITY (ENTERING<br />

WATER TEMP. = 70°C)<br />

NOMINAL AIR FLOW<br />

304 / 12.0<br />

UNIT DIMENSION<br />

1062 / 41.8<br />

222 / 8.7<br />

378 / 14.9<br />

PACKING DIMENSION<br />

1130 / 44.5<br />

292 / 11.5<br />

UNIT WEIGHT<br />

SOUND PRESSURE LEVEL ( H/M/L )<br />

NOMINAL WATER FLOW RATE<br />

HEAD LOSS (COOLING)<br />

HEAD LOSS (HEATING) : 70°C<br />

MAX. WORKING PRESSURE<br />

1608 / 233<br />

SURFACE AIR VELOCITY<br />

FAN COIL WATER VOLUME & MASS<br />

/ kg 1023 / 10.2 1023 / 10.2<br />

CONNECTION<br />

CONTROL<br />

CONDENSATE DRAIN SIZE<br />

ROOM TEMPERATURE<br />

AIR DISCHARGE<br />

OPERATION<br />

mm/in<br />

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.<br />

2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 & ISO13253.<br />

3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :<br />

a) COOLING - ENTERING AIR TEMP. : 27°C (80.6°F) DB / 19°C (66.2°F) WB, ENTERING WATER TEMP. : 7°C (44.6°F), LEAVING WATER TEMP. : 12°C (53.6°F)<br />

b) HEATING - ENTERING AIR TEMP.: 20°C (68°F) DB, ENTERING WATER TEMP. : 70°C (158°F), LEAVING WATER TEMP. : 65°C (149°F)<br />

4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS C 9612 STANDARD. MWMFW : POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 0.8m BELOW THE<br />

UNIT. MWM301W : 1m IN FRONT AND 1 m BELOW THE DISCHARGE OPENING OF THE UNIT (JIS B 8615)<br />

5<br />

1/2" BSP FEMALE ADAPTOR<br />

MICRO-COMPUTER CONTROLLED THERMOSTAT<br />

AUTOMATIC LOUVER (UP& DOWN)<br />

LCD WIRELESS MICRO-COMPUTER REMOTE CONTROL<br />

20 / 0.79


1. RCM - EGENSKAPER<br />

EXTRA SMAL OCH STILFULL DESIGN<br />

Enheterna är konstruerade med tanke på stor flexibilitet och att de ska passa in i olika miljöer<br />

Den smala, kompakta och rundade utformningen av enheterna ger ett mycket elegant intryck.<br />

Inga röranslutningar eller upphängningsdetaljer blir synliga efter monteringen.<br />

CENTRIFUGALFLÄKT MED LÅG LJUDNIVÅ<br />

Enheterna har en låg ljudnivå och är försedda med en fläkt som har tre hastigheter.<br />

INDIVIDUELL REGLERING<br />

Enheterna kan installeras i olika zoner, och varje enhet kan ha sin egen reglerutrustning.<br />

Individuell reglering är energibesparande och det ger bättre komfort och luftdistribution i de<br />

kylda och/eller värmda utrymmena.<br />

PLATSBESPARANDE ENHETER FÖR GOLV- ELLER TAKMONTERING<br />

Enheterna är konstruerade för synligt montage på vägg eller i tak på ett mycket utrymmesbesparande<br />

sätt. Inget behov av att reparera väggar och tak ska normalt uppstå efter monteringen.<br />

Något fundament krävs inte heller för de golvplacerade enheterna. Den enkla<br />

inst<strong>alla</strong>tionen ger ett snabbt montage till en låg kostnad.<br />

STADIG OCH ROBUST KONSTRUKTION<br />

Enheterna är uppbyggda med chassi av ett kraftigt material och med robusta komponenter.<br />

Droppfatet är tillverkat av polystyrenplast och försett med en ytbeläggning som förhindrar att<br />

läckage eller kondens uppstår.<br />

SERVICEVÄNLIGT UTFÖRANDE<br />

Luftfilter, elektriska komponenter, fläkt och fläktmotor kan <strong>alla</strong> enkelt nås för service och<br />

underhåll genom att returluftgallren tas bort. Kyl-/värmebatteriet och droppfatet blir åtkomliga<br />

för rengöring genom att den undre panelen demonteras.<br />

MICROPROCESSORSTYRD REGLERING<br />

Den inbyggda styrutrustningen med fjärrkontroll ger en noggrann reglering, och den har<br />

bland annat följande funktioner:<br />

• Fläktens hastighet kan ställas in på hög/medium/låg eller automatik.<br />

• Timerinställning till/från. Enheterna kan ställas in att automatiskt starta/stoppa vissa tider.<br />

• Elektronisk termostat. Rumstemperaturen får en noggrann reglering vilket leder till bättre<br />

komfort och en energisnålare drift.<br />

• Nattfunktion med högre resp lägre rumstemperatur under natten, vilket betyder att ett rum<br />

inte kyls ner resp värms upp i onödan om det inte används nattetid.<br />

TRÅDLÖS FJÄRRKONTROLL<br />

Med den kompakta trådlösa fjärrkontrollen är det möjligt att var som helst i rummet styra och<br />

ställa in enheternas drift.<br />

AUTOMATISK ELLER MANUELL KONTROLL AV LUFTUTBLÅSNINGEN<br />

Med automatisk kontroll kommer den rörliga luftriktaren att svänga upp och ner, vilket ger en<br />

mycket bra spridning av luften i vertikal riktning. Den horisontella spridningen regleras genom<br />

att justera de vertikala luftriktarna.<br />

6


Teknisk data - RCM-DW<br />

MODEL<br />

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.<br />

2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 & ISO13253.<br />

3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :<br />

a) COOLING - ENTERING AIR TEMP. : 27°C (80.6°F) DB / 19°C (66.2°F) WB, ENTERING WATER TEMP. : 7°C (44.6°F), LEAVING WATER TEMP. : 12°C (53.6°F)<br />

b) HEATING - ENTERING AIR TEMP.: 20°C (68°F) DB, ENTERING WATER TEMP. : 70°C (158°F), LEAVING WATER TEMP. : 65°C (149°F)<br />

4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS C 9612 STANDARD. RCM20/25DW : POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 0.8m BELOW<br />

THE UNIT. RCM30/40/50DW : 1 m IN FRONT OF THE UNIT AND 1m BELOW THE AIR DISCHARGE OPENING. (JIS B 8615)<br />

7<br />

RCM20DW RCM25DW RCM30DW<br />

Btu/h<br />

W<br />

20000<br />

5856<br />

22000<br />

6442<br />

25000<br />

7320<br />

Btu/h<br />

W<br />

15140<br />

4433<br />

16786<br />

4915<br />

18875<br />

5527<br />

Btu/h 35000 40000 46000<br />

W 10248 11712 13469<br />

HIGH l/s / CFM 264 / 560 297 / 630 329 / 700<br />

MEDIUM l/s / CFM 239 / 510 293 / 620 325 / 690<br />

LOW l/s / CFM 193 / 410 262 / 550 306 / 650<br />

HEIGHT mm/in 249 / 9.8<br />

WIDTH mm/in 1214 / 47.8<br />

DEPTH mm/in 670 / 26.4<br />

HEIGHT mm/in 345 / 13.6<br />

WIDTH mm/in 1361 / 53.6<br />

DEPTH mm/in 760 / 29.9<br />

kg/lb 45 / 99.2<br />

dBA 50 / 47 / 40 54 / 53 / 50 51 / 50 / 48<br />

USGPM<br />

LITRES/M<br />

3.90<br />

16.75<br />

4.20<br />

18.42<br />

4.90<br />

21.77<br />

kPa / psi 16.75 / 2.43 19.10 / 2.77 16.96 / 2.46<br />

kPa / psi 13.03 / 1.89 14.89 / 2.16 13.10 / 1.90<br />

kPa / psi<br />

m/s<br />

ft/min<br />

1.38<br />

272.0<br />

1.55<br />

306.0<br />

1.38<br />

272.0<br />

cm 3 NOMINAL TOTAL COOLING CAPACITY<br />

NOMINAL SENSIBLE COOLING CAPACITY<br />

NOMINAL TOTAL HEATING CAPACITY (ENTERING<br />

WATER TEMP. = 70°C)<br />

NOMINAL AIR FLOW<br />

214 / 8.4<br />

UNIT DIMENSION<br />

1214 / 47.8<br />

670 / 26.4<br />

301 / 11.9<br />

PACKING DIMENSION<br />

1311 / 51.6<br />

760 / 29.9<br />

UNIT WEIGHT<br />

43 / 94.8<br />

SOUND PRESSURE LEVEL ( H/M/L )<br />

NOMINAL WATER FLOW RATE<br />

HEAD LOSS (COOLING)<br />

HEAD LOSS (HEATING) : 70°C<br />

MAX. WORKING PRESSURE<br />

1608 / 233<br />

SURFACE AIR VELOCITY<br />

FAN COIL WATER VOLUME & MASS<br />

/ kg 1890 / 18.9 1890 / 18.9 2342 / 23.4<br />

CONNECTION<br />

CONTROL<br />

CONDENSATE DRAIN SIZE<br />

ROOM TEMPERATURE<br />

AIR DISCHARGE<br />

OPERATION<br />

mm/in<br />

3/4" BSP FEMALE ADAPTOR<br />

MICRO-COMPUTER CONTROLLED THERMOSTAT<br />

AUTOMATIC LOUVER (UP& DOWN)<br />

LCD WIRELESS MICRO-COMPUTER REMOTE CONTROL<br />

19.05 / 3/4


Teknisk data - RCM-DW<br />

MODEL<br />

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.<br />

2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 & ISO13253.<br />

3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :<br />

a) COOLING - ENTERING AIR TEMP. : 27°C (80.6°F) DB / 19°C (66.2°F) WB, ENTERING WATER TEMP. : 7°C (44.6°F), LEAVING WATER TEMP. : 12°C (53.6°F)<br />

b) HEATING - ENTERING AIR TEMP.: 20°C (68°F) DB, ENTERING WATER TEMP. : 70°C (158°F), LEAVING WATER TEMP. : 65°C (149°F)<br />

4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS C 9612 STANDARD. RCM20/25DW : POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 0.8m BELOW<br />

THE UNIT. RCM30/40/50DW : 1 m IN FRONT OF THE UNIT AND 1m BELOW THE AIR DISCHARGE OPENING. (JIS B 8615)<br />

8<br />

RCM40DW RCM50DW<br />

Btu/h<br />

W<br />

40000<br />

11712<br />

45000<br />

13176<br />

Btu/h<br />

W<br />

29200<br />

8550<br />

32535<br />

9526<br />

Btu/h 75000 85000<br />

W 21960 24888<br />

HIGH l/s / CFM 450 / 950 500 / 1060<br />

MEDIUM l/s / CFM 428 / 910 483 / 1020<br />

LOW l/s / CFM 420 / 890 450 / 950<br />

HEIGHT mm/in<br />

WIDTH mm/in<br />

DEPTH mm/in<br />

HEIGHT mm/in<br />

WIDTH mm/in<br />

DEPTH mm/in<br />

kg/lb<br />

dBA 54 / 53 / 52 54 / 53 / 52<br />

USGPM<br />

LITRES/M<br />

8.60<br />

31.82<br />

9.30<br />

40.19<br />

kPa / psi 11.86 / 1.72 13.58 / 1.97<br />

kPa / psi 9.10 / 1.32 10.48 / 1.52<br />

kPa / psi<br />

m/s<br />

ft/min<br />

1.22<br />

241.0<br />

1.36<br />

267.0<br />

cm 3 NOMINAL TOTAL COOLING CAPACITY<br />

NOMINAL SENSIBLE COOLING CAPACITY<br />

NOMINAL TOTAL HEATING CAPACITY (ENTERING<br />

WATER TEMP. = 70°C)<br />

NOMINAL AIR FLOW<br />

249 / 9.8<br />

UNIT DIMENSION<br />

1714 / 67.5<br />

670 / 26.4<br />

345 / 13.6<br />

PACKING DIMENSION<br />

1361 / 53.6<br />

760 / 29.9<br />

UNIT WEIGHT<br />

70 / 154.3<br />

SOUND PRESSURE LEVEL ( H/M/L )<br />

NOMINAL WATER FLOW RATE<br />

HEAD LOSS (COOLING)<br />

HEAD LOSS (HEATING) : 70°C<br />

MAX. WORKING PRESSURE<br />

1608 / 233<br />

SURFACE AIR VELOCITY<br />

FAN COIL WATER VOLUME & MASS<br />

/ kg 4578 / 45.8 4578 / 45.8<br />

CONNECTION<br />

CONTROL<br />

CONDENSATE DRAIN SIZE<br />

ROOM TEMPERATURE<br />

AIR DISCHARGE<br />

OPERATION<br />

mm/in<br />

3/4" BSP FEMALE ADAPTOR<br />

MICRO-COMPUTER CONTROLLED THERMOSTAT<br />

AUTOMATIC LOUVER (UP& DOWN)<br />

LCD WIRELESS MICRO-COMPUTER REMOTE CONTROL<br />

19.05 / 3/4


1. ACK - EGENSKAPER<br />

EXTRA SMAL OCH STILFULL DESIGN<br />

Enheterna är konstruerade med tanke på stor flexibilitet samt att de ska passa in i olika miljöer. Den<br />

låga (endast 28 mm) och rundade profilen på frontpanelen ger ett mycket elegant intryck.<br />

CENTRIFUGALFLÄKT MED LÅG LJUDNIVÅ<br />

Fläkten har tre varvtal och låg ljudnivå. Den är utformad för att ge jämn luftdistribution i <strong>alla</strong> riktningar.<br />

INBYGGD KONDENSVATTENPUMP<br />

Enheterna har en inbyggd kondensvattenpump med 500 mm pumphöjd. Detta förenklar arbetet med<br />

dragning av kondensvattenavloppet.<br />

STADIG OCH ROBUST KONSTRUKTION<br />

Enheterna är uppbyggda med chassi av ett kraftigt material och med robusta komponenter. Droppfatet<br />

är tillverkat av polystyrenplast och försett med en ytbeläggning som förhindrar att läckage eller kondens<br />

uppstår.<br />

SERVICEVÄNLIGT UTFÖRANDE<br />

Luftfilter, elektriska komponenter, fläkt, fläktmotor och kondensvattenpump kan <strong>alla</strong> enkelt nås för<br />

service och underhåll genom att returluftgallret tas bort. Om frontpanelen tas bort kan droppfatet och<br />

kyl-/värmebatteriet demonteras.<br />

MICROPROCESSOR MED FJÄRRKONTROLL<br />

Den inbyggda styrutrustningen med fjärrkontroll ger en noggrann reglering, och den har bl a följande<br />

funktioner.<br />

• Fläktens hastighet kan ställas in på hög/medium/låg eller automatik.<br />

• Timerinställning till/från. Enheterna kan förinställas att automatiskt starta och stoppa vissa tider.<br />

• Elektronisk termostat. Rumstemperaturen får en noggrann reglering vilket leder till bättre komfort<br />

och en energisnålare drift.<br />

TRÅDLÖS FJÄRRKONTROLL<br />

Med den kompakta trådlösa fjärrkontrollen är det möjligt att var som helst i rummet styra och ställa in<br />

enheternas drift.<br />

9


Teknisk data - ACK-CW<br />

MODEL<br />

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.<br />

2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 & ISO13253.<br />

3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :<br />

a) COOLING - ENTERING AIR TEMP. : 27°C (80.6°F) DB / 19°C (66.2°F) WB, ENTERING WATER TEMP. : 7°C (44.6°F), LEAVING WATER TEMP. : 12°C (53.6°F)<br />

b) HEATING - ENTERING AIR TEMP.: 20°C (68°F) DB, ENTERING WATER TEMP. : 70°C (158°F), LEAVING WATER TEMP. : 65°C (149°F)<br />

4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS C 9612 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.4m BELOW THE FACIA.<br />

10<br />

ACK10CW ACK15CW ACK20CW<br />

Btu/h<br />

W<br />

9000<br />

2635<br />

15000<br />

4392<br />

16900<br />

4948<br />

Btu/h<br />

W<br />

7000<br />

2050<br />

11000<br />

3221<br />

12000<br />

3514<br />

Btu/h 20000 31000 33500<br />

W 5856 9077 9809<br />

HIGH l/s / CFM 203 / 430<br />

MEDIUM l/s / CFM 193 / 410<br />

LOW l/s / CFM 184 / 390<br />

HEIGHT mm/in<br />

WIDTH mm/in<br />

DEPTH mm/in<br />

HEIGHT mm/in<br />

WIDTH mm/in<br />

DEPTH mm/in<br />

kg/lb ( 22+2 ) / ( 0.9+0.1 )<br />

dBA 44 / 43 / 42 44 / 42 / 41 47 / 46 / 44<br />

USGPM<br />

LITRES/M<br />

1.90<br />

7.19<br />

3.35<br />

12.68<br />

3.60<br />

13.63<br />

kPa / psi 57.42 / 8.33 30.83 / 4.47 35.83 / 5.20<br />

kPa / psi 44.37 / 6.44 24.00 / 3.48 27.30 / 3.96<br />

kPa / psi<br />

m/s<br />

ft/min<br />

0.77<br />

151.8<br />

0.60<br />

118.0<br />

0.66<br />

129.4<br />

cm 3 NOMINAL TOTAL COOLING CAPACITY<br />

NOMINAL SENSIBLE COOLING CAPACITY<br />

NOMINAL TOTAL HEATING CAPACITY (ENTERING<br />

WATER TEMP. = 70°C)<br />

184 / 390<br />

NOMINAL AIR FLOW<br />

175 / 370<br />

165 / 350<br />

250 / 9.8 ( 295 / 11.6 )<br />

UNIT DIMENSION - ( ) WITH PANEL<br />

570 / 22.4 ( 640 / 25.2 )<br />

570 / 22.4 ( 640 / 25.2 )<br />

317 / 12.5 ( 127 / 5.0 )<br />

PACKING DIMENSION<br />

( ) - PANEL<br />

630 / 24.8 ( 700 / 27.6 )<br />

630 / 24.8 ( 700 / 27.6 )<br />

UNIT WEIGHT ( UNIT + PANEL ) ( 23+2 ) / ( 0.9+0.1 )<br />

SOUND PRESSURE LEVEL ( H/M/L )<br />

NOMINAL WATER FLOW RATE<br />

HEAD LOSS (COOLING)<br />

HEAD LOSS (HEATING) : 70°C<br />

MAX. WORKING PRESSURE 1608 / 233<br />

SURFACE AIR VELOCITY<br />

FAN COIL WATER VOLUME & MASS<br />

/ kg 435 / 4.4 845 / 8.5 845 / 8.5<br />

CONNECTION 3/4" BSP FEMALE UNION<br />

CONTROL<br />

ROOM TEMPERATURE MICRO-COMPUTER CONTROLLED THERMOSTAT<br />

AIR DISCHARGE AUTOMATIC LOUVER (UP& DOWN)<br />

OPERATION LCD WIRELESS MICRO-COMPUTER REMOTE CONTROL<br />

CONDENSATE DRAIN SIZE mm/in<br />

19.05 / 3/4


Teknisk data - ACK-AW<br />

MODEL<br />

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.<br />

2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 & ISO13253.<br />

3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :<br />

a) COOLING - ENTERING AIR TEMP. : 27°C (80.6°F) DB / 19°C (66.2°F) WB, ENTERING WATER TEMP. : 7°C (44.6°F), LEAVING WATER TEMP. : 12°C (53.6°F)<br />

b) HEATING - ENTERING AIR TEMP.: 20°C (68°F) DB, ENTERING WATER TEMP. : 70°C (158°F), LEAVING WATER TEMP. : 65°C (149°F)<br />

4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS C 9612 STANDARD. ACK20/25AW/AWH : POSITION OF THE MEASUREMENT POINT IS 1.4m BELOW THE FACIA.<br />

ACK30/40/50AW/AWH : 1.5m BELOW THE FACIA (JIS B 8615).<br />

11<br />

ACK20AW ACK25AW ACK30AW<br />

Btu/h<br />

W<br />

24000<br />

7027<br />

25600<br />

7496<br />

29500<br />

8638<br />

Btu/h<br />

W<br />

17800<br />

5212<br />

18800<br />

5505<br />

21600<br />

6324<br />

Btu/h 50900 53000 60900<br />

W 14917 15533 17848<br />

HIGH l/s / CFM 349 / 740 368 / 780 415 / 880<br />

MEDIUM l/s / CFM 297 / 630 312 / 660 349 / 740<br />

LOW l/s / CFM 283 / 600 283 / 600 321 / 680<br />

HEIGHT mm/in<br />

WIDTH mm/in<br />

DEPTH mm/in<br />

HEIGHT mm/in<br />

WIDTH mm/in<br />

DEPTH mm/in<br />

kg/lb ( 31+4 ) / ( 1.2+0.2 ) ( 32+4 ) / ( 1.3+0.2 ) ( 35+4 ) / ( 1.4+0.2 )<br />

dBA 42 / 39 / 37 45 / 42 / 40 49 / 45 / 43<br />

USGPM<br />

LITRES/M<br />

5.50<br />

20.82<br />

5.80<br />

21.96<br />

6.70<br />

25.36<br />

kPa / psi 19.44 / 2.82 23.58 / 3.42 30.47 / 4.42<br />

kPa / psi 16.74 / 2.43 18.48 / 2.68 24.27 / 3.52<br />

kPa / psi<br />

m/s<br />

ft/min<br />

0.71<br />

139.8<br />

0.75<br />

147.9<br />

0.85<br />

166.5<br />

cm 3 NOMINAL TOTAL COOLING CAPACITY<br />

NOMINAL SENSIBLE COOLING CAPACITY<br />

NOMINAL TOTAL HEATING CAPACITY (ENTERING<br />

WATER TEMP. = 70°C)<br />

NOMINAL AIR FLOW<br />

335 / 13.2 ( 363 / 14.3 )<br />

UNIT DIMENSION - ( ) WITH PANEL<br />

820 / 32.3 ( 930 / 36.6 )<br />

821 / 32.3 ( 930 / 36.6 )<br />

380 / 15.0 ( 130 / 5.1 )<br />

PACKING DIMENSION<br />

( ) - PANEL<br />

920 / 36.2 ( 1020 / 40.2 )<br />

920 / 36.2 (1000 / 39.4 )<br />

UNIT WEIGHT ( UNIT + PANEL )<br />

SOUND PRESSURE LEVEL ( H/M/L )<br />

NOMINAL WATER FLOW RATE<br />

HEAD LOSS (COOLING)<br />

HEAD LOSS (HEATING) : 70°C<br />

MAX. WORKING PRESSURE 1608 / 233<br />

SURFACE AIR VELOCITY<br />

FAN COIL WATER VOLUME & MASS<br />

/ kg 2963 / 29.6 2963 / 29.6 2963 / 29.6<br />

CONNECTION 3/4" BSP FEMALE UNION<br />

CONTROL<br />

ROOM TEMPERATURE MICRO-COMPUTER CONTROLLED THERMOSTAT<br />

AIR DISCHARGE AUTOMATIC LOUVER (UP& DOWN)<br />

OPERATION LCD WIRELESS MICRO-COMPUTER REMOTE CONTROL<br />

CONDENSATE DRAIN SIZE mm/in<br />

19.05 / 3/4


Teknisk data - ACK-AW<br />

MODEL<br />

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.<br />

2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 & ISO13253.<br />

3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :<br />

a) COOLING - ENTERING AIR TEMP. : 27°C (80.6°F) DB / 19°C (66.2°F) WB, ENTERING WATER TEMP. : 7°C (44.6°F), LEAVING WATER TEMP. : 12°C (53.6°F)<br />

b) HEATING - ENTERING AIR TEMP.: 20°C (68°F) DB, ENTERING WATER TEMP. : 70°C (158°F), LEAVING WATER TEMP. : 65°C (149°F)<br />

4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS C 9612 STANDARD. ACK20/25AW/AWH : POSITION OF THE MEASUREMENT POINT IS 1.4m BELOW THE FACIA.<br />

ACK30/40/50AW/AWH : 1.5m BELOW THE FACIA (JIS B 8615).<br />

12<br />

ACK40AW ACK50AW<br />

Btu/h<br />

W<br />

35000<br />

10248<br />

40000<br />

11712<br />

Btu/h<br />

W<br />

25500<br />

7466<br />

29600<br />

8667<br />

Btu/h 66600 69100<br />

W 19519 20251<br />

HIGH l/s / CFM 467 / 990 491 / 1040<br />

MEDIUM l/s / CFM 406 / 860 448 / 950<br />

LOW l/s / CFM 359 / 760 411 / 870<br />

HEIGHT mm/in<br />

WIDTH mm/in<br />

DEPTH mm/in<br />

HEIGHT mm/in<br />

WIDTH mm/in<br />

DEPTH mm/in<br />

kg/lb ( 38+4 ) / ( 1.5+0.2 ) ( 40+4 ) / ( 1.6+0.2 )<br />

dBA 51 / 48 / 46 53 / 52 / 50<br />

USGPM<br />

LITRES/M<br />

7.30<br />

27.63<br />

7.50<br />

28.39<br />

kPa / psi 35.44 / 5.14 37.16 / 5.39<br />

kPa / psi 28.41 / 4.12 29.85 / 4.33<br />

kPa / psi<br />

m/s<br />

ft/min<br />

0.95<br />

187.6<br />

1.00<br />

197.3<br />

cm 3 NOMINAL TOTAL COOLING CAPACITY<br />

NOMINAL SENSIBLE COOLING CAPACITY<br />

NOMINAL TOTAL HEATING CAPACITY (ENTERING<br />

WATER TEMP. = 70°C)<br />

NOMINAL AIR FLOW<br />

335 / 13.2 ( 363 / 14.3 )<br />

UNIT DIMENSION - ( ) WITH PANEL<br />

820 / 32.3 ( 930 / 36.6 )<br />

821 / 32.3 ( 930 / 36.6 )<br />

380 / 15.0 ( 130 / 5.1 )<br />

PACKING DIMENSION<br />

( ) - PANEL<br />

920 / 36.2 ( 1020 / 40.2 )<br />

920 / 36.2 (1000 / 39.4 )<br />

UNIT WEIGHT ( UNIT + PANEL )<br />

SOUND PRESSURE LEVEL ( H/M/L )<br />

NOMINAL WATER FLOW RATE<br />

HEAD LOSS (COOLING)<br />

HEAD LOSS (HEATING) : 70°C<br />

MAX. WORKING PRESSURE 1608 / 233<br />

SURFACE AIR VELOCITY<br />

FAN COIL WATER VOLUME & MASS<br />

/ kg 2963 / 29.6 2963 / 29.6<br />

CONNECTION 3/4" BSP FEMALE UNION<br />

CONTROL<br />

ROOM TEMPERATURE MICRO-COMPUTER CONTROLLED THERMOSTAT<br />

AIR DISCHARGE AUTOMATIC LOUVER (UP& DOWN)<br />

OPERATION LCD WIRELESS MICRO-COMPUTER REMOTE CONTROL<br />

CONDENSATE DRAIN SIZE mm/in<br />

19.05 / 3/4


1. ACC - EGENSKAPER<br />

DISKRET AGGREGAT<br />

Eftersom aggregatet är inbyggt i undertaket så är endast luftdon synliga i rummet. Detta<br />

gör att aggregatet inte på verkar inredningen nämnvärt.<br />

Inga röranslutningar eller upphängningsdetaljer blir synliga efter monteringen.<br />

CENTRIFUGALFLÄKT MED LÅG LJUDNIVÅ<br />

Enheterna har en låg ljudnivå och är försedda med en fläkt som har tre hastigheter.<br />

INDIVIDUELL REGLERING<br />

Enheterna kan installeras i olika zoner, och varje enhet kan ha sin egen reglerutrustning.<br />

Individuell reglering är energibesparande och det ger bättre komfort och luftdistribution i de<br />

kylda utrymmena.<br />

TRÅDBUNDEN FJÄRRKONTROLL<br />

Aggregatet utrustas med trådbunden fjärrkontroll, därifrån man enkelt kan styra aggregatets<br />

funktioner.<br />

Inställning av fläktens hastighet låg, medium, hög eller automatik, timer med till- och frånslag,<br />

rumstemperaturen mellan 16-30 grader, nattsänkning m.m.<br />

STADIG OCH ROBUST KONSTRUKTION<br />

Enheterna är uppbyggda med chassi av ett kraftigt material och med robusta komponenter.<br />

Dubbla droppfat och dräneringar för att säkerställa att inga ovälkommna läckage av<br />

kondensvatten uppstår.<br />

SERVICEVÄNLIGT UTFÖRANDE<br />

Luftfilter, elektriska komponenter, fläkt och fläktmotor kan <strong>alla</strong> enkelt nås för service och<br />

underhåll.<br />

MICROPROCESSORSTYRD REGLERING<br />

Den inbyggda styrutrustningen med fjärrkontroll ger en noggrann reglering, och den har<br />

bland annat följande funktioner:<br />

• Fläktens hastighet kan ställas in på hög/medium/låg eller automatik.<br />

• Timerinställning till/från. Enheterna kan ställas in att automatiskt starta/stoppa vissa tider.<br />

• Elektronisk termostat. Rumstemperaturen får en noggrann reglering vilket leder till bättre<br />

komfort och en energisnålare drift.<br />

• Nattfunktion med högre resp lägre rumstemperatur under natten, vilket betyder att ett rum<br />

inte kyls ner resp värms upp i onödan om det inte används nattetid.<br />

13


Teknisk data - ACC-CW<br />

MODEL<br />

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.<br />

2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 & ISO13253.<br />

3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :<br />

a) COOLING - ENTERING AIR TEMP. : 27°C (80.6°F) DB / 19°C (66.2°F) WB, ENTERING WATER TEMP. : 7°C (44.6°F), LEAVING WATER TEMP. : 12°C (53.6°F)<br />

b) HEATING - ENTERING AIR TEMP.: 20°C (68°F) DB, ENTERING WATER TEMP. : 70°C (158°F), LEAVING WATER TEMP. : 65°C (149°F)<br />

4) SOUND PRESSURE LEVEL ARE ACCORDING TO GB STD - GB/D17758. POSITION OF THE MEASUREMENT POINT IS 1.4m BELOW THE CENTRE OF THE UNIT.<br />

TESTED WITH 2m LENGTH DUCT AT THE AIR DISCHARGE OUTLET ANS AIR RETURN INLET.<br />

14<br />

ACC10CW ACC15CW ACC20CW<br />

Btu/h<br />

W<br />

9900<br />

2902<br />

15000<br />

4396<br />

18000<br />

5275<br />

Btu/h<br />

W<br />

7000<br />

2052<br />

10000<br />

2931<br />

13600<br />

3986<br />

Btu/h 19000 25500 38000<br />

W 5569 7474 11137<br />

HIGH l/s / CFM 142 / 300 241 / 510 330 / 700<br />

MEDIUM l/s / CFM 123 / 260 208 / 440 321 / 680<br />

LOW l/s / CFM 104 / 220 170 / 360 293 / 620<br />

mmAq 5 / 4 / 3 5 / 4 / 3 5 / 4 / 3<br />

HEIGHT mm/in 261 / 10.3 262 / 10.3 263 / 10.3<br />

WIDTH mm/in 765 / 30.1 905 / 35.6 1065 / 41.9<br />

DEPTH mm/in 411 / 16.2 412 / 16.2 413 / 16.2<br />

HEIGHT mm/in 410 / 16.1 411 / 16.1 412 / 16.1<br />

WIDTH mm/in 951 / 37.4 1091 / 43.0 1251 / 49.3<br />

DEPTH mm/in 535 / 21.1 536 / 21.1 537 / 21.1<br />

kg/lb 17 / 37.5 21 / 46.3 22 / 48.5<br />

dBA 33 / 30 / 26 37 / 34 / 29 38 / 36 / 34<br />

USGPM<br />

LITRES/M<br />

2.00<br />

7.57<br />

2.58<br />

9.77<br />

4.20<br />

15.90<br />

kPa / psi 8.83 / 1.28 13.97 / 2.03 18.28 / 2.65<br />

kPa / psi 6.69 / 0.97 10.76 / 1.56 14.20 / 2.06<br />

kPa / psi<br />

m/s<br />

ft/min<br />

109.00<br />

232.0<br />

153.00<br />

324.0<br />

312.00<br />

147.0<br />

cm 3 NOMINAL TOTAL COOLING CAPACITY<br />

NOMINAL SENSIBLE COOLING CAPACITY<br />

NOMINAL TOTAL HEATING CAPACITY (ENTERING<br />

WATER TEMP. = 70°C)<br />

NOMINAL AIR FLOW<br />

EXTERNAL STATIC ( H/M/L )<br />

UNIT DIMENSION<br />

PACKING DIMENSION<br />

UNIT WEIGHT<br />

SOUND PRESSURE LEVEL ( H/M/L )<br />

NOMINAL WATER FLOW RATE<br />

HEAD LOSS (COOLING)<br />

HEAD LOSS (HEATING) : 70°C<br />

MAX. WORKING PRESSURE<br />

1608 / 233<br />

SURFACE AIR VELOCITY<br />

FAN COIL WATER VOLUME & MASS<br />

/ kg 1108 / 11.1 1356 / 13.6 1678 / 16.8<br />

CONNECTION<br />

CONTROL<br />

CONDENSATE DRAIN SIZE<br />

ROOM TEMPERATURE<br />

OPERATION<br />

mm/in<br />

3/4" BSP FEMALE ADAPTOR<br />

MICRO-COMPUTER CONTROLLED THERMOSTAT<br />

LCD WIRELESS MICRO-COMPUTER REMOTE CONTROL<br />

19.05 / 3/4


Teknisk data - ACC-CW<br />

MODEL<br />

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.<br />

2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 & ISO13253.<br />

3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :<br />

a) COOLING - ENTERING AIR TEMP. : 27°C (80.6°F) DB / 19°C (66.2°F) WB, ENTERING WATER TEMP. : 7°C (44.6°F), LEAVING WATER TEMP. : 12°C (53.6°F)<br />

b) HEATING - ENTERING AIR TEMP.: 20°C (68°F) DB, ENTERING WATER TEMP. : 70°C (158°F), LEAVING WATER TEMP. : 65°C (149°F)<br />

4) SOUND PRESSURE LEVEL ARE ACCORDING TO GB STD - GB/D17758. POSITION OF THE MEASUREMENT POINT IS 1.4m BELOW THE CENTRE OF THE UNIT.<br />

TESTED WITH 2m LENGTH DUCT AT THE AIR DISCHARGE OUTLET ANS AIR RETURN INLET.<br />

15<br />

ACC25CW ACC28CW<br />

Btu/h<br />

W<br />

22500<br />

6594<br />

26000<br />

7620<br />

Btu/h<br />

W<br />

17900<br />

5246<br />

19500<br />

5715<br />

Btu/h 48000 55000<br />

W 14068 16120<br />

SUPER HIGH l/s / CFM NA 401 / 850<br />

HIGH<br />

MEDIUM<br />

l/s / CFM<br />

l/s / CFM<br />

345 / 730<br />

340 / 720<br />

382 / 810<br />

363 / 770<br />

LOW l/s / CFM 274 / 580 335 / 710<br />

mmAq 5 / 4 / 3 10 / 8 / 7 / 6<br />

HEIGHT mm/in 261 / 10.3 290 / 11.4<br />

WIDTH mm/in 1200 / 47.2 942 / 37.1<br />

DEPTH mm/in 411 / 16.2 600 / 23.6<br />

HEIGHT mm/in 410 / 16.1 327 / 12.9<br />

WIDTH mm/in 1386 / 54.6 1122 / 44.2<br />

DEPTH mm/in 535 / 21.1 674 / 26.5<br />

kg/lb 25 / 55.1 38 / 83.8<br />

dBA 40 / 39 / 36 44 / 41 / 38 / 34<br />

USGPM<br />

LITRES/M<br />

4.70<br />

17.79<br />

5.70<br />

21.58<br />

kPa / psi 24.12 / 3.50 14.69 / 2.13<br />

kPa / psi 18.96 / 2.75 11.38 / 1.65<br />

kPa / psi<br />

m/s<br />

ft/min<br />

173.0<br />

366.0<br />

146.0<br />

309.0<br />

cm 3 NOMINAL TOTAL COOLING CAPACITY<br />

NOMINAL SENSIBLE COOLING CAPACITY<br />

NOMINAL TOTAL HEATING CAPACITY (ENTERING<br />

WATER TEMP. = 70°C)<br />

NOMINAL AIR FLOW<br />

EXTERNAL STATIC ( H/M/L )<br />

UNIT DIMENSION<br />

PACKING DIMENSION<br />

UNIT WEIGHT<br />

SOUND PRESSURE LEVEL ( H/M/L )<br />

NOMINAL WATER FLOW RATE<br />

HEAD LOSS (COOLING)<br />

HEAD LOSS (HEATING) : 70°C<br />

MAX. WORKING PRESSURE<br />

1608 / 233<br />

SURFACE AIR VELOCITY<br />

FAN COIL WATER VOLUME & MASS<br />

/ kg 1920 / 19.2 2321 / 23.2<br />

CONNECTION<br />

CONTROL<br />

CONDENSATE DRAIN SIZE<br />

ROOM TEMPERATURE<br />

OPERATION<br />

mm/in<br />

3/4" BSP FEMALE ADAPTOR<br />

MICRO-COMPUTER CONTROLLED THERMOSTAT<br />

LCD WIRELESS MICRO-COMPUTER REMOTE CONTROL<br />

19.05 / 3/4


Teknisk data - ACC-CW<br />

MODEL<br />

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.<br />

2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 & ISO13253.<br />

3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :<br />

a) COOLING - ENTERING AIR TEMP. : 27°C (80.6°F) DB / 19°C (66.2°F) WB, ENTERING WATER TEMP. : 7°C (44.6°F), LEAVING WATER TEMP. : 12°C (53.6°F)<br />

b) HEATING - ENTERING AIR TEMP.: 20°C (68°F) DB, ENTERING WATER TEMP. : 70°C (158°F), LEAVING WATER TEMP. : 65°C (149°F)<br />

4) SOUND PRESSURE LEVEL ARE ACCORDING TO GB STD - GB/D17758. POSITION OF THE MEASUREMENT POINT IS 1.4m BELOW THE CENTRE OF THE UNIT.<br />

TESTED WITH 2m LENGTH DUCT AT THE AIR DISCHARGE OUTLET ANS AIR RETURN INLET.<br />

16<br />

ACC30CW ACC30CW ACC40CW<br />

Btu/h<br />

W<br />

28000<br />

8206<br />

35000<br />

10258<br />

38000<br />

11137<br />

Btu/h<br />

W<br />

21800<br />

6389<br />

27600<br />

8089<br />

34000<br />

9965<br />

Btu/h 60000 65000 75000<br />

W 17585 19050 21981<br />

SUPER HIGH l/s / CFM 425 / 900 727 / 1540 519 / 1100<br />

HIGH<br />

MEDIUM<br />

l/s / CFM<br />

l/s / CFM<br />

392 / 830<br />

359 / 760<br />

694 / 1470<br />

670 / 1420<br />

500 / 1060<br />

467 / 990<br />

LOW l/s / CFM 335 / 710 637 / 1350 425 / 900<br />

mmAq 21 / 17 / 13 / 9 14 / 12 / 11 / 9 21/ 18 / 13 / 9<br />

HEIGHT mm/in 378 / 14.9 310 / 12.2 378 / 14.9<br />

WIDTH mm/in 929 / 36.6 1247 / 49.1 1045 / 41.1<br />

DEPTH mm/in 541 / 21.3 638 / 25.1 541 / 21.3<br />

HEIGHT mm/in 399 / 15.7 339 / 13.4 399 / 15.7<br />

WIDTH mm/in 1110 / 43.7 1445 / 56.9 1229 / 48.4<br />

DEPTH mm/in 615 / 24.2 711 / 28.0 615 / 24.2<br />

kg/lb 39 / 86.0 41 / 90.4 42 / 92.6<br />

dBA 49 / 46 / 42 / 38 55 / 51 / 48 / 45 51 / 49 / 45 / 41<br />

USGPM<br />

LITRES/M<br />

6.20<br />

23.47<br />

9.60<br />

36.34<br />

7.40<br />

28.01<br />

kPa / psi 12.82 / 1.89 44.24 / 6.42 18.86 / 2.74<br />

kPa / psi 9.86 / 1.43 35.78 / 5.19 14.69 / 2.13<br />

kPa / psi<br />

m/s<br />

ft/min<br />

151.0<br />

320.0<br />

192.0<br />

406.0<br />

170.0<br />

360.0<br />

cm 3 NOMINAL TOTAL COOLING CAPACITY<br />

NOMINAL SENSIBLE COOLING CAPACITY<br />

NOMINAL TOTAL HEATING CAPACITY (ENTERING<br />

WATER TEMP. = 70°C)<br />

NOMINAL AIR FLOW<br />

EXTERNAL STATIC ( SH/H/M/L )<br />

UNIT DIMENSION<br />

PACKING DIMENSION<br />

UNIT WEIGHT<br />

SOUND PRESSURE LEVEL ( SH/H/M/L )<br />

NOMINAL WATER FLOW RATE<br />

HEAD LOSS (COOLING)<br />

HEAD LOSS (HEATING) : 70°C<br />

MAX. WORKING PRESSURE<br />

1608 / 233<br />

SURFACE AIR VELOCITY<br />

FAN COIL WATER VOLUME & MASS<br />

/ kg 2714 / 27.1 3123 / 31.2 3093 / 30.9<br />

CONNECTION<br />

CONTROL<br />

CONDENSATE DRAIN SIZE<br />

ROOM TEMPERATURE<br />

OPERATION<br />

mm/in<br />

3/4" BSP FEMALE ADAPTOR<br />

MICRO-COMPUTER CONTROLLED THERMOSTAT<br />

LCD WIRELESS MICRO-COMPUTER REMOTE CONTROL<br />

19.05 / 3/4


Teknisk data - ACC-CW<br />

MODEL<br />

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.<br />

2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 & ISO13253.<br />

3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :<br />

a) COOLING - ENTERING AIR TEMP. : 27°C (80.6°F) DB / 19°C (66.2°F) WB, ENTERING WATER TEMP. : 7°C (44.6°F), LEAVING WATER TEMP. : 12°C (53.6°F)<br />

b) HEATING - ENTERING AIR TEMP.: 20°C (68°F) DB, ENTERING WATER TEMP. : 70°C (158°F), LEAVING WATER TEMP. : 65°C (149°F)<br />

4) SOUND PRESSURE LEVEL ARE ACCORDING TO GB STD - GB/D17758. POSITION OF THE MEASUREMENT POINT IS 1.4m BELOW THE CENTRE OF THE UNIT.<br />

TESTED WITH 2m LENGTH DUCT AT THE AIR DISCHARGE OUTLET ANS AIR RETURN INLET.<br />

17<br />

ACC50CW ACC60CW<br />

Btu/h<br />

W<br />

47000<br />

13775<br />

54000<br />

15826<br />

Btu/h<br />

W<br />

34700<br />

10170<br />

39900<br />

11694<br />

Btu/h 95000 110000<br />

W 27843 32239<br />

SUPER HIGH l/s / CFM 750 / 1590 779 / 1650<br />

HIGH<br />

MEDIUM<br />

l/s / CFM<br />

l/s / CFM<br />

651 / 1380<br />

604 / 1280<br />

722 / 1530<br />

675 / 1430<br />

LOW l/s / CFM 571 / 1210 609 / 1290<br />

mmAq 18 / 16 / 14 / 11 18 / 16 / 14 / 10<br />

HEIGHT mm/in 378 / 14.9 379 / 14.9<br />

WIDTH mm/in 1299 / 51.1 1499 / 59.0<br />

DEPTH mm/in 541 / 21.3 542 / 21.3<br />

HEIGHT mm/in 399 / 15.7 399 / 15.7<br />

WIDTH mm/in 1481 / 58.3 1685 / 66.3<br />

DEPTH mm/in 615 / 24.2 615 / 24.2<br />

kg/lb 54 / 119.0 62 / 136.7<br />

dBA 53 / 52 / 50 / 47 55 / 53 / 50 / 47<br />

USGPM<br />

LITRES/M<br />

10.00<br />

37.85<br />

10.80<br />

40.88<br />

kPa / psi 37.08 / 5.38 7.01 / 1.02<br />

kPa / psi 29.65 / 4.30 5.38 / 0.78<br />

kPa / psi<br />

m/s<br />

ft/min<br />

159.0<br />

336.0<br />

157.0<br />

333.0<br />

cm 3 NOMINAL TOTAL COOLING CAPACITY<br />

NOMINAL SENSIBLE COOLING CAPACITY<br />

NOMINAL TOTAL HEATING CAPACITY (ENTERING<br />

WATER TEMP. = 70°C)<br />

NOMINAL AIR FLOW<br />

EXTERNAL STATIC ( SH/H/M/L )<br />

UNIT DIMENSION<br />

PACKING DIMENSION<br />

UNIT WEIGHT<br />

SOUND PRESSURE LEVEL ( SH/H/M/L )<br />

NOMINAL WATER FLOW RATE<br />

HEAD LOSS (COOLING)<br />

HEAD LOSS (HEATING) : 70°C<br />

MAX. WORKING PRESSURE<br />

1608 / 233<br />

SURFACE AIR VELOCITY<br />

FAN COIL WATER VOLUME & MASS<br />

/ kg 3893 / 38.9 4512 / 45.1<br />

CONNECTION<br />

CONTROL<br />

CONDENSATE DRAIN SIZE<br />

ROOM TEMPERATURE<br />

OPERATION<br />

mm/in<br />

7/8" BSP FEMALE ADAPTOR<br />

MICRO-COMPUTER CONTROLLED THERMOSTAT<br />

LCD WIRELESS MICRO-COMPUTER REMOTE CONTROL<br />

19.05 / 3/4


AWM-GW<br />

MODEL<br />

FAN MOTOR<br />

MODEL<br />

FAN MOTOR<br />

AWM 301W<br />

MODEL<br />

FAN MOTOR<br />

3. ELEKTRISK DATA<br />

AWM07GW AWM10GW AWM15GW<br />

INSULATION GRADE<br />

B B B<br />

POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50 220 - 240 / 1 / 50<br />

RATED INPUT POWER W 24 26 29<br />

RATED RUNNING CURRENT A 0.11 0.11 0.13<br />

MOTOR OUTPUT W 8 9 13<br />

POLES<br />

4 4 4<br />

AWM20GW AWM25GW<br />

INSULATION GRADE<br />

B B<br />

POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50<br />

RATED INPUT POWER W 69 70<br />

RATED RUNNING CURRENT A 0.29 0.29<br />

MOTOR OUTPUT W 25 55<br />

POLES<br />

4 4<br />

INSULATION GRADE<br />

AWM301W<br />

F<br />

POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50<br />

RATED INPUT POWER W 68<br />

RATED RUNNING CURRENT A 0.30<br />

MOTOR OUTPUT W 40<br />

POLES<br />

4<br />

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.<br />

2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.<br />

18


Elektriska data - RCM-DW<br />

MODEL<br />

FAN MOTOR<br />

MODEL<br />

FAN MOTOR<br />

RCM-CBW<br />

MODEL<br />

FAN MOTOR<br />

ACM-EW<br />

MODEL<br />

FAN MOTOR<br />

RCM20DW RCM25DW RCM30DW<br />

INSULATION GRADE<br />

B B B<br />

POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50 220 - 240 / 1 / 50<br />

RATED INPUT POWER W 88 118 120<br />

RATED RUNNING CURRENT A 0.40 0.58 0.58<br />

MOTOR OUTPUT W 40 65 65<br />

POLES<br />

4 4 4<br />

RCM40DW RCM50DW<br />

INSULATION GRADE<br />

B B<br />

POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50<br />

RATED INPUT POWER W 217 217<br />

RATED RUNNING CURRENT A 1.04 1.04<br />

MOTOR OUTPUT W 100 100<br />

POLES<br />

4 4<br />

RCM07CBW RCM10CBW RCM15CBW<br />

INSULATION GRADE<br />

B B B<br />

POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50 220 - 240 / 1 / 50<br />

RATED INPUT POWER W 47 52 75<br />

RATED RUNNING CURRENT A 0.22 0.24 0.34<br />

MOTOR OUTPUT W 20 20 30<br />

POLES<br />

4 4 4<br />

ACM15EW ACM20EW ACM25EW<br />

INSULATION GRADE<br />

B B B<br />

POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50 220 - 240 / 1 / 50<br />

RATED INPUT POWER W 101 109 113<br />

RATED RUNNING CURRENT A 0.46 0.49 0.51<br />

MOTOR OUTPUT W 50 65 70<br />

POLES<br />

4 4 4<br />

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.<br />

2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.<br />

19


Elektriska data - ACK-AW<br />

MODEL<br />

FAN MOTOR<br />

MODEL<br />

FAN MOTOR<br />

ACK-BW<br />

MODEL<br />

FAN MOTOR<br />

ACK-CW<br />

MODEL<br />

FAN MOTOR<br />

ACK-AWH<br />

MODEL<br />

FAN MOTOR<br />

MODEL<br />

FAN MOTOR<br />

ACK20AW ACK25AW ACK30AW<br />

INSULATION GRADE<br />

E E E<br />

POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50 220 - 240 / 1 / 50<br />

RATED INPUT POWER W 121 144 156<br />

RATED RUNNING CURRENT A 0.53 0.65 0.69<br />

MOTOR OUTPUT W 35 45 60<br />

POLES<br />

6 6 6<br />

ACK40AW ACK50AW<br />

INSULATION GRADE<br />

E E<br />

POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50<br />

RATED INPUT POWER W 183 241<br />

RATED RUNNING CURRENT A 0.80 1.08<br />

MOTOR OUTPUT W 83 120<br />

POLES<br />

6 6<br />

ACK15BW ACK20BW ACK25BW<br />

INSULATION GRADE<br />

E E E<br />

POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50 220 - 240 / 1 / 50<br />

RATED INPUT POWER W 69 69 75<br />

RATED RUNNING CURRENT A 0.30 0.30 0.31<br />

MOTOR OUTPUT W 22 22 30<br />

POLES<br />

6 6 6<br />

ACK10CW ACK15CW ACK20CW<br />

INSULATION GRADE<br />

E E E<br />

POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50 220 - 240 / 1 / 50<br />

RATED INPUT POWER W 56 63 74<br />

RATED RUNNING CURRENT A 0.24 0.28 0.31<br />

MOTOR OUTPUT W 16 18 22<br />

POLES<br />

6 6 6<br />

ACK20AWH ACK25AWH ACK30AWH<br />

INSULATION GRADE<br />

E E E<br />

POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50 220 - 240 / 1 / 50<br />

RATED INPUT POWER W 121 144 156<br />

RATED RUNNING CURRENT A 0.53 0.65 0.69<br />

MOTOR OUTPUT W 35 45 60<br />

POLES<br />

6 6 6<br />

ACK40AWH ACK50AWH<br />

INSULATION GRADE<br />

E E<br />

POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50<br />

RATED INPUT POWER W 183 241<br />

RATED RUNNING CURRENT A 0.80 1.08<br />

MOTOR OUTPUT W 83 120<br />

POLES<br />

6 6<br />

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.<br />

2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.<br />

20


Elektriska data - ACC-CW<br />

MODEL<br />

FAN MOTOR<br />

MODEL<br />

FAN MOTOR<br />

MODEL<br />

FAN MOTOR<br />

MODEL<br />

FAN MOTOR<br />

ACC10CW ACC15CW ACC20CW<br />

INSULATION GRADE<br />

E E E<br />

POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50 220 - 240 / 1 / 50<br />

RATED INPUT POWER W 68 97 141<br />

RATED RUNNING CURRENT A 0.30 0.43 0.65<br />

MOTOR OUTPUT W 30 50 80<br />

POLES<br />

4 4 4<br />

ACC25CW ACC28CW ACC30CW<br />

INSULATION GRADE<br />

E B B<br />

POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50 220 - 240 / 1 / 50<br />

RATED INPUT POWER W 172 286 401<br />

RATED RUNNING CURRENT A 0.74 1.30 1.90<br />

MOTOR OUTPUT W 100 320 320<br />

POLES<br />

4 4 4<br />

ACC38CW ACC40CW ACC50CW<br />

INSULATION GRADE<br />

B B B<br />

POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50 220 - 240 / 1 / 50<br />

RATED INPUT POWER W 536 524 638<br />

RATED RUNNING CURRENT A 2.40 2.60 2.90<br />

MOTOR OUTPUT W 470 400 480<br />

POLES<br />

4 4 4<br />

INSULATION GRADE<br />

ACC60CW<br />

B<br />

POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50<br />

RATED INPUT POWER W 713<br />

RATED RUNNING CURRENT A 3.20<br />

MOTOR OUTPUT W 600<br />

POLES<br />

4<br />

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.<br />

2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.<br />

21


4. Komponentdata AWM-GW<br />

MODEL<br />

COIL<br />

AIR FILTER<br />

TYPE<br />

Q'TY<br />

FAN MATERIAL<br />

FAN MOTOR<br />

CASING<br />

MODEL<br />

FAN<br />

FAN MOTOR<br />

COIL<br />

AIR FILTER<br />

CASING<br />

DRIVE<br />

LENGTH x DIAMETER<br />

TYPE<br />

Q'TY<br />

INDEX OF PROTECTION (IP)<br />

TYPE<br />

TUBE<br />

FIN<br />

MATERIAL<br />

SIZE ( L x W x t )<br />

MATERIAL<br />

COLOUR<br />

TYPE<br />

MATERIAL<br />

DIAMETER mm/in<br />

THICKNESS mm/in<br />

MATERIAL<br />

Q'TY<br />

MATERIAL<br />

DRIVE<br />

LENGTH x DIAMETER<br />

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.<br />

AWM07GW AWM10GW<br />

AWM15GW<br />

mm/in 617.5 x 97 ( 24.3 x 3.8 )<br />

THICKNESS mm/in<br />

FACE AREA m 2 / ft 2 0.20 / 2.16<br />

ROW<br />

2<br />

FIN PER INCH<br />

18<br />

TYPE<br />

Q'TY<br />

INDEX OF PROTECTION (IP)<br />

TYPE<br />

TUBE<br />

FIN<br />

MATERIAL<br />

MATERIAL<br />

COLOUR<br />

MATERIAL<br />

mm/in<br />

mm/in<br />

DIAMETER mm/in<br />

THICKNESS mm/in<br />

MATERIAL<br />

THICKNESS mm/in<br />

FACE AREA m 2 / ft 2<br />

ROW<br />

SIZE ( L x W x t )<br />

FIN PER INCH<br />

22<br />

1 1<br />

1<br />

1 1<br />

1<br />

IP24 IP24<br />

IP24<br />

CROSS FLOW FAN<br />

1 1<br />

1<br />

IP20<br />

ANTI FUNGUS SKEW FAN<br />

ACRYLO NITRILE STYRENE<br />

DIRECT<br />

INDUCTION<br />

CROSS FINNED TUBES<br />

PLAIN COPPER<br />

7.00 / 0.28<br />

0.32 / 0.013<br />

ALUMINIUM<br />

0.11 / 0.004<br />

ACRYLO NITRILE STYRENE<br />

DIRECT<br />

810 x 108 ( 31.9 x 4.3 )<br />

INDUCTION<br />

CROSS FINNED TUBES<br />

PLAIN COPPER<br />

7.00 / 0.28<br />

0.32 / 0.013<br />

ALUMINIUM<br />

0.11 / 0.004<br />

717.5 x 97 ( 28.2 x 3.8 )<br />

0.23 / 2.52<br />

2<br />

18<br />

WASHABLE SARANNET (NANO FILTER)<br />

AWM20GW<br />

304 x 298 x 1.5 ( 11.9 x 11.7 x 0.1 )<br />

HIGH IMPACT POLYSTYRENE<br />

LIGHT GREY<br />

0.27 / 2.90<br />

2<br />

18<br />

WASHABLE SARANNET (NANO FILTER)<br />

mm/in 351 x 386 x 105 ( 13.8 x 15.2 x 0.1 )<br />

HIGH IMPACT POLYSTYRENE<br />

LIGHT GREY<br />

AWM25GW<br />

1<br />

IP20


Komponentdata - RCM-DW<br />

MODEL<br />

FAN<br />

FAN MOTOR<br />

COIL<br />

AIR FILTER<br />

CASING<br />

MODEL<br />

FAN<br />

FAN MOTOR<br />

COIL<br />

AIR FILTER<br />

CASING<br />

TYPE<br />

Q'TY<br />

MATERIAL<br />

DRIVE<br />

DIAMETER x LENGTH<br />

TYPE<br />

Q'TY<br />

INDEX OF PROTECTION (IP)<br />

TYPE<br />

TUBE<br />

FIN<br />

MATERIAL<br />

Q'TY<br />

SIZE ( L x W x t )<br />

MATERIAL<br />

COLOUR<br />

mm/in<br />

DIAMETER mm/in<br />

THICKNESS mm/in<br />

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.<br />

23<br />

RCM20DW RCM25DW RCM30DW<br />

2 2 3<br />

1 1 1<br />

NA NA NA<br />

THICKNESS mm/in<br />

FACE AREA m 2 / ft 2 0.11 / 0.004<br />

0.19 / 2.06 0.19 / 2.06 0.24 / 2.57<br />

ROW<br />

3 3 3<br />

FIN PER INCH<br />

12 12 12<br />

PC/S 2 2 2<br />

mm<br />

544 x 270 x 3<br />

in<br />

21.4 x 10.6 x 0.1<br />

ELECTRO-GALVANIZED MILD STEEL<br />

LIGHT GREY<br />

RCM40DW RCM50DW<br />

4 4<br />

mm/in<br />

1 1<br />

NA NA<br />

DIAMETER mm/in<br />

THICKNESS mm/in<br />

THICKNESS mm/in<br />

FACE AREA m 2 / ft 2 TYPE<br />

CROSS FLOW FAN<br />

Q'TY<br />

MATERIAL<br />

ABS<br />

DRIVE<br />

DIRECT<br />

DIAMETER x LENGTH<br />

146 x 200 / 5.8 x 7.9<br />

TYPE<br />

INDUCTION<br />

Q'TY<br />

INDEX OF PROTECTION (IP)<br />

TYPE<br />

CROSS FINNED TUBES<br />

MATERIAL<br />

INNER GROOVED COPPER<br />

TUBE<br />

9.52 / 3/8<br />

0.33 / 0.013<br />

MATERIAL<br />

CORRUGATED ALUMINIUM<br />

0.11 / 0.004<br />

FIN<br />

0.37 / 3.96 0.37 / 3.96<br />

ROW<br />

4 4<br />

FIN PER INCH<br />

12 14<br />

MATERIAL<br />

WASHABLE SARANNET<br />

Q'TY<br />

PC/S 2 + 1 2 + 3<br />

mm 514 x 270 x 3 (2 pcs) 500 x 285 x 3 (2 pcs)<br />

SIZE ( L x W x t )<br />

MATERIAL<br />

COLOUR<br />

MATERIAL<br />

MATERIAL<br />

mm 494 x 270 x 3 (1 pc) 400 x 285 x 3 (3 pcs)<br />

in 21.4 x 10.6 x 0.1 (2 pcs) 19.6 x 11.2 x 0.1 (2 pcs)<br />

in 19.4 x 10.6 x 0.1 (1 pc) 15.7 x 11.2 x 0.1 (3 pcs)<br />

ELECTRO-GALVANIZED MILD STEEL<br />

LIGHT GREY<br />

CROSS FLOW FAN<br />

ABS<br />

DIRECT<br />

146 x 200 / 5.8 x 7.9<br />

INDUCTION<br />

CROSS FINNED TUBES<br />

PLAIN COPPER TUBE<br />

9.52 / 3/8<br />

0.33 / 0.013<br />

CORRUGATED ALUMINIUM<br />

WASHABLE SARANNET


Komponent data - ACK-AW<br />

MODEL<br />

FAN MATERIAL<br />

DRIVE<br />

DIAMETER<br />

FAN MOTOR<br />

COIL<br />

AIR FILTER<br />

CASING<br />

MODEL<br />

FAN<br />

FAN MOTOR<br />

COIL<br />

AIR FILTER<br />

CASING<br />

TYPE<br />

Q'TY<br />

TYPE<br />

Q'TY<br />

INDEX OF PROTECTION (IP)<br />

TYPE<br />

TUBE<br />

FIN<br />

MATERIAL<br />

mm/in<br />

DIAMETER mm/in<br />

THICKNESS mm/in<br />

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.<br />

24<br />

ACK20AW ACK25AW ACK30AW<br />

THICKNESS mm/in<br />

FACE AREA m 2 / ft 2 0.11 / 0.004<br />

0.47 / 5.02 0.47 / 5.03 0.47 / 5.04<br />

ROW<br />

2 2 2<br />

FIN PER INCH<br />

14 14 16<br />

SIZE ( L x W x t ) mm/in<br />

TYPE<br />

Q'TY<br />

MATERIAL<br />

DRIVE<br />

DIAMETER<br />

TYPE<br />

Q'TY<br />

INDEX OF PROTECTION (IP)<br />

TYPE<br />

TUBE<br />

FIN<br />

MATERIAL<br />

mm/in<br />

DIAMETER mm/in<br />

THICKNESS mm/in<br />

THICKNESS mm/in<br />

FACE AREA m 2 / ft 2<br />

SIZE ( L x W x t ) mm/in<br />

MATERIAL (PANEL)<br />

PANEL COLOUR<br />

MATERIAL<br />

MATERIAL<br />

MATERIAL (PANEL)<br />

PANEL COLOUR<br />

MATERIAL<br />

MATERIAL<br />

ROW<br />

FIN PER INCH<br />

576 x 556 x 22 / 22.7 x 21.9 x 0.9<br />

ELECTRO-GALVANIZED MILD STEEL (ABS )<br />

LIGHT GREY<br />

ACK40AW ACK50AW<br />

TURBO FAN<br />

1<br />

ASG20<br />

DIRECT<br />

450 / 17.7<br />

INDUCTION<br />

1<br />

IP22<br />

CROSS FINNED TUBES<br />

PLAIN COPPER TUBE<br />

9.52 / 3/8<br />

0.33 / 0.013<br />

ALUMINIUM SLIT FIN<br />

0.11 / 0.004<br />

0.47 / 5.02<br />

2 2<br />

16 16<br />

WASHABLE SARANNET<br />

576 x 556 x 22 / 22.7 x 21.9 x 0.9<br />

ELECTRO-GALVANIZED MILD STEEL (ABS )<br />

LIGHT GREY<br />

TURBO FAN<br />

1<br />

ASG20<br />

DIRECT<br />

450 / 17.7<br />

INDUCTION<br />

1<br />

IP22<br />

CROSS FINNED TUBES<br />

PLAIN COPPER TUBE<br />

9.52 / 3/8<br />

0.33 / 0.013<br />

ALUMINIUM SLIT FIN<br />

WASHABLE SARANNET


Komponent data - ACK-CW<br />

ACK10CW ACK15CW<br />

1 1<br />

mm/in<br />

1 1<br />

NA NA<br />

DIAMETER mm/in<br />

THICKNESS mm/in<br />

THICKNESS mm/in<br />

FACE AREA m 2 / ft 2 MODEL<br />

TYPE<br />

TURBO FAN<br />

Q'TY<br />

FAN MATERIAL<br />

ASG20<br />

DRIVE<br />

DIRECT<br />

DIAMETER<br />

330 / 13.0<br />

TYPE<br />

INDUCTION<br />

FAN MOTOR Q'TY<br />

INDEX OF PROTECTION (IP)<br />

TYPE<br />

CROSS FINNED TUBES<br />

MATERIAL<br />

INNER GROOVE COPPER TUBE<br />

TUBE<br />

7.00 / 0.276<br />

0.28 / 0.011<br />

COIL<br />

MATERIAL<br />

ALUMINIUM SLIT FIN<br />

0.11 / 0.004<br />

FIN<br />

0.24 / 2.583 0.309 / 3.323<br />

ROW<br />

1 2<br />

FIN PER INCH<br />

16 20<br />

AIR FILTER MATERIAL<br />

WASHABLE SARANNET<br />

SIZE ( L x W x t ) mm/in<br />

368 x 381 x 21 / 14.5 x 15 x 0.8<br />

CASING<br />

MATERIAL (PANEL)<br />

PANEL COLOUR<br />

ELECTRO-GALVANIZED MILD STEEL ( ABS )<br />

LIGHT GREY<br />

MODEL<br />

FAN<br />

FAN MOTOR<br />

COIL<br />

AIR FILTER<br />

CASING<br />

mm/in<br />

DIAMETER mm/in<br />

THICKNESS mm/in<br />

THICKNESS mm/in<br />

FACE AREA m 2 / ft 2<br />

TYPE<br />

Q'TY<br />

MATERIAL<br />

DRIVE<br />

DIAMETER<br />

TYPE<br />

Q'TY<br />

INDEX OF PROTECTION (IP)<br />

TYPE<br />

MATERIAL<br />

TUBE<br />

MATERIAL<br />

FIN<br />

MATERIAL<br />

ROW<br />

FIN PER INCH<br />

SIZE ( L x W x t ) mm/in<br />

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.<br />

25<br />

ACK20CW<br />

TURBO FAN<br />

1<br />

ASG20<br />

DIRECT<br />

330 / 13.0<br />

INDUCTION<br />

1<br />

NA<br />

CROSS FINNED TUBES<br />

BARE COPPER TUBE<br />

7.00 / 0.276<br />

0.28 / 0.011<br />

ALUMINIUM SLIT FIN<br />

0.11 / 0.004<br />

0.309 / 3.323<br />

2<br />

20<br />

WASHABLE SARANNET<br />

368 x 381 x 21 / 14.5 x 15 x 0.8<br />

MATERIAL (PANEL) ELECTRO-GALVANIZED MILD STEEL ( ABS )<br />

PANEL COLOUR<br />

LIGHT GREY


Komponentdata - ACC-CW<br />

MODEL<br />

FAN MATERIAL<br />

DRIVE<br />

DIAMETER x LENGTH<br />

FAN MOTOR<br />

COIL<br />

AIR FILTER<br />

CASING<br />

MODEL<br />

FAN<br />

FAN MOTOR<br />

COIL<br />

AIR FILTER<br />

CASING<br />

TYPE<br />

Q'TY<br />

TYPE<br />

Q'TY<br />

INDEX OF PROTECTION (IP)<br />

TYPE<br />

TUBE<br />

FIN<br />

MATERIAL<br />

Q'TY<br />

SIZE ( L x W x t )<br />

MATERIAL<br />

COLOUR<br />

TYPE<br />

Q'TY<br />

MATERIAL<br />

DRIVE<br />

DIAMETER x LENGTH<br />

TYPE<br />

TUBE<br />

FIN<br />

MATERIAL<br />

MATERIAL<br />

COLOUR<br />

MATERIAL<br />

mm/in<br />

DIAMETER mm/in<br />

THICKNESS mm/in<br />

MATERIAL<br />

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.<br />

26<br />

ACC10CW ACC15CW ACC20CW<br />

1 2 2<br />

NA NA NA<br />

1 1 1<br />

NA NA NA<br />

THICKNESS mm/in<br />

FACE AREA m 2 / ft 2 0.11 / 0.004<br />

0.12 / 1.24 0.12 / 1.26 0.18 / 1.89<br />

ROW<br />

3 3 3<br />

FIN PER INCH<br />

12 14 12<br />

TYPE<br />

Q'TY<br />

INDEX OF PROTECTION (IP)<br />

Q'TY<br />

SIZE ( L x W x t )<br />

MATERIAL<br />

DIAMETER mm/in<br />

THICKNESS mm/in<br />

MATERIAL<br />

CENTRIFUGAL<br />

DIRECT<br />

160 x 202 / 6.3 x 8.0<br />

INDUCTION<br />

CROSS FINNED TUBES<br />

PLAIN COPPER TUBE<br />

9.52 / 3/8<br />

0.33 / 0.013<br />

CORRUGATED ALUMINIUM<br />

WASHABLE SARANNET<br />

PC/S 1 1 1<br />

mm 560 x 195 x 5 700 x 195 x 5 860 x 195 x 5<br />

in 22.1 x 7.7 x 0.2 27.6 x 7.7 x 0.2 33.9 x 7.7 x 0.2<br />

ELECTRO-GALVANIZED MILD STEEL<br />

LIGHT GREY<br />

ACC25CW ACC28CW ACC30CW<br />

CENTRIFUGAL<br />

2 2 2<br />

NA NA NA<br />

DIRECT<br />

mm/in 160 x 202 / 6.3 x 8.0 185 x 203 / 7.3 x 8.0 210 x 203 / 8.4 x 8.0<br />

INDUCTION<br />

1 1 1<br />

NA NA NA<br />

CROSS FINNED TUBES<br />

PLAIN COPPER TUBE<br />

9.52 / 3/8<br />

0.33 / 0.013<br />

CORRUGATED ALUMINIUM<br />

THICKNESS mm/in<br />

FACE AREA m 2 / ft 2 0.11 / 0.004<br />

0.20 / 2.19 0.24 / 2.62 0.28 / 2.98<br />

ROW<br />

3 3 3<br />

FIN PER INCH<br />

12 14 12<br />

WASHABLE SARANNET<br />

PC/S 1 2 2<br />

mm 995 x 195 x 5 456 x 210 x 5 449 x 305 x 5<br />

in 39.2 x 7.7 x 0.2 18.0 x 8.3 x 0.2 17.7 x 12.0 x 0.2<br />

ELECTRO-GALVANIZED MILD STEEL<br />

LIGHT GREY


Komponentdata - ACC-CW<br />

MODEL<br />

COIL<br />

CASING<br />

TYPE<br />

Q'TY<br />

FAN MATERIAL<br />

FAN MOTOR<br />

AIR FILTER<br />

MODEL<br />

FAN<br />

FAN MOTOR<br />

COIL<br />

AIR FILTER<br />

CASING<br />

DRIVE<br />

DIAMETER x LENGTH<br />

TYPE<br />

Q'TY<br />

INDEX OF PROTECTION (IP)<br />

TYPE<br />

TUBE<br />

FIN<br />

MATERIAL<br />

Q'TY<br />

SIZE ( L x W x t )<br />

MATERIAL<br />

COLOUR<br />

TYPE<br />

Q'TY<br />

MATERIAL<br />

DRIVE<br />

MATERIAL<br />

mm/in<br />

DIAMETER mm/in<br />

THICKNESS mm/in<br />

MATERIAL<br />

DIAMETER x LENGTH<br />

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.<br />

27<br />

ACC38CW ACC40CW<br />

2 2<br />

NA NA<br />

1 1<br />

NA NA<br />

THICKNESS mm/in<br />

FACE AREA m 2 / ft 2 0.11 / 0.004<br />

0.34 / 3.63 0.32 / 3.44<br />

ROW<br />

3 3<br />

FIN PER INCH<br />

14 12<br />

TYPE<br />

Q'TY<br />

INDEX OF PROTECTION (IP)<br />

TYPE<br />

TUBE<br />

FIN<br />

MATERIAL<br />

Q'TY<br />

SIZE ( L x W x t )<br />

MATERIAL<br />

COLOUR<br />

MATERIAL<br />

PC/S 2 2<br />

mm 608 x 230 x 5 507 x 305 x 5<br />

in 23.9 x 9.1 x 0.2 20.0 x 12.0 x 0.2<br />

mm/in<br />

DIAMETER mm/in<br />

THICKNESS mm/in<br />

MATERIAL<br />

CENTRIFUGAL FAN<br />

DIRECT<br />

214 x 203 / 8.4 x 8.0<br />

INDUCTION<br />

CROSS FINNED TUBES<br />

PLAIN COPPER TUBE<br />

9.52 / 3/8<br />

0.33 / 0.013<br />

CORRUGATED ALUMINIUM<br />

WASHABLE SARANNET<br />

ELECTRO-GALVANIZED MILD STEEL<br />

LIGHT GREY<br />

ACC50CW ACC60CW<br />

CENTRIFUGAL FAN<br />

2 2<br />

NA NA<br />

DIRECT<br />

214 x 203 / 8.4 x 8.0<br />

INDUCTION<br />

1 1<br />

NA NA<br />

CROSS FINNED TUBES<br />

PLAIN COPPER TUBE<br />

9.52 / 3/8<br />

0.33 / 0.013<br />

CORRUGATED ALUMINIUM<br />

THICKNESS mm/in<br />

FACE AREA m 2 / ft 2 0.11 / 0.004<br />

0.41 / 4.40 0.48 / 5.17<br />

ROW<br />

3 3<br />

FIN PER INCH<br />

12 12<br />

WASHABLE SARANNET<br />

PC/S 2 2<br />

mm 634 x 305 x 5 734 x 305 x 5<br />

in 25.0 x 12.0 x 0.2 29.0 x 12.0 x 0.2<br />

ELECTRO-GALVANIZED MILD STEEL<br />

LIGHT GREY


Inomhusdel<br />

Modell : AWM 07GW<br />

Inomhusdel<br />

Modell : AWM 10 / 15 GW<br />

5. DIMENSIONER<br />

28<br />

Dimension in mm<br />

Dimension in mm


Inomhusdel<br />

Modell : AWM 20 / 25GW<br />

Inomhusdel<br />

Modell : AWM 301W<br />

Dimension A B C D E<br />

AWM301W 1120.0 (44.1) 360.0 (14.2) 200.0 (7.9) 730.0 (28.7) 347.0 (13.7)<br />

All dimensions are in mm/ (in)<br />

29


Inomhusdel<br />

Modell : RCM 20 / 25 DW<br />

Inomhusdel<br />

Modell : RCM 30 / 40 / 50 DW<br />

30<br />

Dimension in mm<br />

MODEL A B C D E F G H I J K L M N O P Q<br />

RCM30DW 1174 75 1082 68 93 156 1214 57 670 216 319 879 517 100 47 100 53<br />

RCM40DW 1674 75 1582 68 93 156 1714 57 670 216 319 1379 517 95 40 100 45<br />

RCM50DW 1674 75 1582 68 93 156 1714 57 670 216 319 1379 517 95 40 100 45<br />

Dimension in mm


Inomhusdel<br />

Modell : ACK 20 / 25 / 30 / 40 / 50 AW<br />

Inomhusdel<br />

Modell : ACK 15 / 20 / 25 BW<br />

31<br />

Dimension in mm<br />

Dimension in mm


Inomhusdel<br />

Modell : ACK 10 / 15 / 20 CW<br />

Inomhusdel<br />

Modell : ACK 20 / 25 / 30 / 40 / 50 AWH<br />

32<br />

Dimension in mm<br />

Water Inlet/Outlet 1 = connection to chiller<br />

Water Inlet/Outlet 2 = connection to boiler<br />

Dimension in mm


Inomhusdel<br />

Modell : ACC 10 / 15CW<br />

MODEL A B C D E F G H I J K L M N O<br />

ACC10CW 31 741 702 662 10 765 72 261 411 349 225 261 171 118 77<br />

ACC15CW 31 881 841 802 10 905 72 261 411 349 225 261 171 118 77<br />

Inomhusdel<br />

Modell : ACC 20 / 25 CW<br />

33<br />

Dimension in mm<br />

MODEL A B C D E F G H I J K L M N O P<br />

ACC20CW 31 1041 1002 962 10 1065 72 261 411 349 225 261 174 128 55 55<br />

ACC25CW 31 1176 1137 1097 10 1200 72 261 411 349 225 261 171 118 77 54<br />

Dimension in mm


Inomhusdel<br />

Modell : ACC 28CW<br />

34<br />

Dimension in mm


Inomhusdel<br />

Modell : ACC 30CW<br />

35<br />

Dimension in mm


Inomhusdel<br />

Modell : ACC 38CW<br />

36<br />

Dimension in mm


Inomhusdel<br />

Modell : ACC 40CW<br />

37<br />

Dimension in mm


Inomhusdel<br />

Modell : ACC 50CW<br />

38<br />

Dimension in mm


Inomhusdel<br />

Modell : ACC 60CW<br />

39<br />

Dimension in mm


Modell : AWM 07 / 10 / 15GW<br />

Modell : AWM 20 / 25 GW<br />

6. ELSCHEMA<br />

40


Modell : RCM 20 / 25 / 30 / 40 / 50DW<br />

Modell : RCM 07 / 15 CBW<br />

41


Modell : ACK 20 / 25 / 30 / 40 / 50AW<br />

Modell : ACK 15 / 20 / 25 BW<br />

42


Modell : ACK 10 / 15 / 20CW<br />

Modell : ACK 20 / 25 / 30 / 40 / 50 AWH<br />

43


Modell : ACC 10 / 15 / 20 / 25CW<br />

Modell : ACC 28 / 30 / 38 / 40 / 50 / 60CW<br />

44


AWM - GW<br />

Innedelen måste installeras så att kortslutning av luftflödet<br />

in och ut ur aggregatet inte kan uppstå. Följ montage<br />

anvisningens minsta avstånd till hinder se bild nedan.<br />

Placera inte innedelen där den kan utsättas för direkt<br />

solljus. Se också till att det är möjligt att förlägga kondens-<br />

avlopp och vattenrör, samt att innedelen inte är ivägen<br />

för dörrar och fönster.<br />

Montage plåt<br />

Se till att väggen är kraftig nog för att klara av innedelens tyngd.<br />

Annars måste väggen förstärkas.<br />

Använd vattenpass och fäst plåten med 4 skruvar.<br />

Om rören skall förläggas genom väggen förborra med65mm<br />

hålsåg, borra så att hålet blir något lägre på utsidan(se bild).<br />

Håltagning<br />

Borra vägggenomföringen med ett lätt fall<br />

från insidan ut.<br />

7. INSTALLATION<br />

Montera innedelen på montageplåten<br />

Häng upp innedelen på de övre hållarna på montageplåten,<br />

se till att innedelen får ordentligt fäste genom att<br />

skjuta innedelen försiktigt i sidled.<br />

Kondensvattenavlopp<br />

Se till att kondensavloppet är förlagt med fall från<br />

innedelen. Se bild.<br />

45


Vattenröranslutning<br />

Fläktkonvektorn är försedd med oislerade anslutningar för in och utgående rörledningar. På batteriets högsta punkt<br />

finns en avluftningsventil monterad. Tryck på ventilen för att avlufta batteriet.<br />

En trevägsventil krävs för att stänga av eller reglera vätskeflödet till fläktkonvektorn.<br />

Svarta stålrör, kopparrör, PVC-rör eller polyetenrör kan användas. Material måste väljas med hänsyn till typ av vätska mm.<br />

Alla köldbärarledningar och anslutningar måste isoleras mot kondens med syntetiskt cellgummi typ armaflex eller liknande.<br />

Använd ej invändigt nedsmutsade rör eller skadade rör och rördelar till inst<strong>alla</strong>tionen.<br />

Vissa huvudkomponenter är nödvändiga att montera i rörsystemet för att öka kapaciteten och förenkla vid service, t ex<br />

avstängningsventiler, injusteringsventiler, filter, silar, 2 eller 3-vägsventiler mm.<br />

ELANSLUTNINGAR<br />

Modell WM07GW / WM10GW / WM15GW WM20GW / WM25GW<br />

Spänningsområde 220V – 240V/1Ph / 50Hz +<br />

Kabelstorlek mm2 1.5 1.5<br />

Antal kardeler 3 3<br />

Rekommenderad avsäkring A 10 10<br />

Chiller<br />

WM07-25GW<br />

46<br />

3 way valve<br />

Relay (220-240V, 10A)


Varning<br />

Skarpa kanter och batteriets flänsar utgör potentiell risk för skärskador. Undvik direktkontakt med dem.<br />

FÖRSTA FÖRBEREDELSER<br />

• Den elektriska matningen samt el- / rörinst<strong>alla</strong>tioner ska följa gällande föreskrifter och bestämmelser.<br />

• Spänningen får inte variera mer än ±10% av nominell spänning. Elmatningen får inte innehålla<br />

några svetstransformatorer, eftersom de orsakar stora störningar och ostabilitet i elnätet.<br />

• Montera enheten på en plats som är lämplig för rördragning och elinst<strong>alla</strong>tion.<br />

• Enheten ska monteras så att luften från enheten kan få fritt flöde ut och spridas i rummet, och inte<br />

hindras av belysningsarmaturer, balkar mm. Inte heller returluften in till enheten får hindras.<br />

STANDARDMONTAGE<br />

Försäkra er om att taket är tillräckligt starkt att bära vikten av enheten. Montera pendlarna för upphängningen<br />

(väggmontagejärn vid golvuppställning) i rätt läge enligt måtten som visas i figur A. Kontrollera<br />

att infästningen av pendlarna är riktigt förankrade och att enheten monteras i våg. Observera att det<br />

för kondensvattnets avrinning dock ska vara en viss lutning enligt vad som rekommenderas i figur B.<br />

odell RCM 20D RCM 25D RCM 30D RCM 40D RCM50D<br />

1214 1214 1214 1714 1714<br />

666 666 666 666 666<br />

273 273 273 273 273<br />

130 130 130 130 130<br />

F 1160 1160 1560 1560 1560<br />

27 27 27 27 27<br />

77 77 77 77 77<br />

745 745 745 1235 1235<br />

25 25 25 25 25<br />

209 209 209 331 331<br />

486 486 486 486 486<br />

108 108 108 108 108<br />

360 360 360 600 600<br />

770 770 770 1270 1270<br />

136 136 136 136 136<br />

Q 373 373 373 373 373<br />

222 222 222 310 310<br />

Observera! Alla mått är angivna i mm.<br />

Figur B<br />

47<br />

- RCM - DW<br />

10 mm<br />

10 mm högre<br />

Figur A


Vid montaget ska man se till att:<br />

• enheten får den i figur B rekommenderade lutningen för avrinning av kondensvattnet.<br />

• enheten runt om får ett fritt utrymme enligt figur C, vilket förenklar service och ger rätt luftflöde.<br />

• enheten monteras så att det inte uppstår någon kortslutning mellan den behandlade utblåsningsluften<br />

och den inkommande returluften.<br />

• enheten inte monteras så att den utsätts för direkt solbestrålning. Vidare ska montageplatsen vara<br />

lämplig för montage av rörledningar. Placera enheten långt ifrån dörren och så att drag inte uppstår.<br />

Figur C<br />

INSTALLATION - DELVIS INFÄLLT TAKMONTAGE<br />

• Kontrollera att enheten riktas in på rätt sätt i förhållande till undertaket.<br />

• Fritt utrymme runt enheten krävs enligt vad som framgår av figur D.<br />

Figur D<br />

TAKMODELL MÖBLER, INBYGGDA BYGGNADS-<br />

TEKNISKA KONSTRUKTIONER MM<br />

FÅR INTE SKJUTA UT MER ÄN 250 MM<br />

Undertakspanel<br />

48<br />

GOLVMODELL<br />

Enhetens överkant


ÖPPET TAKMONTAGE<br />

STEG 1<br />

Ta bort returluftgaller, sidopanel, sidotäckplåt och montagekonsol från enheten (se fig E).<br />

Figur E<br />

STEG 2<br />

Montera montagekonsolerna enligt de mått som anges i fig A (se fig F).<br />

Figur F<br />

STEG 3<br />

Häng upp enheten och spänn fast bultarna. När rör- och elinst<strong>alla</strong>tionerna är färdiga sätts de<br />

borttagna komponenterna - returluftgaller, sidopanel och sidotäckplåt - tillbaks på enheten<br />

(se fig G).<br />

Figur G<br />

49<br />

Returluftgaller<br />

Sidotäckplåt<br />

Montagekonsol<br />

Sidopanel


GOLVMONTAGE<br />

STEG 1<br />

Ta bort returluftgaller, sidopanel, sidotäckplåt och montagekonsol från enheten (se fig E).<br />

STEG 2<br />

Sätt fast vägg*- och uppställningskonsolerna enligt de mått som anges i fig A, och sätt upp<br />

enheten (se fig H).<br />

Figur H<br />

STEG 3<br />

Anslut rörledningarna enligt något av de två olika inkopplingsalternativen i fig J.<br />

Rörledningar<br />

genom bakre plåten<br />

Inst<strong>alla</strong>tion av rörledningar<br />

Figur J<br />

50<br />

* Väggkonsoler levereras<br />

som extra tillbehör mot<br />

särskild beställning.<br />

Vägg<br />

Rörledningar<br />

genom bottenplåten


ANSLUTNING AV KÖLD- ELLER VÄRMEBÄRARLEDNINGAR<br />

- Fläktkonvektorn är försedd med oisolerade anslutningar för in- och utgående rörledningar. På batteriets<br />

högsta punkt finns en avluftningsventil monterad. Tryck på ventilen för att avlufta batteriet.<br />

- En 3-vägs magnetventil eller reglerventil krävs för att stänga av eller reglera vätskeflödet till enheten.<br />

- Svarta stålrör, kopparrör, PVC-rör eller polyetenrör kan användas. Material måste väljas med hänsyn<br />

till typ av vätska mm.<br />

- Alla köldbärarledningar och anslutningar måste isoleras mot kondens med syntetiskt cellgummi typ<br />

Armaflex eller liknande.<br />

- Använd ej invändigt nedsmutsade rör eller skadade rör och rördelar till inst<strong>alla</strong>tionen.<br />

- Vissa huvudkomponeneter är nödvändiga att montera i rörsystemet för att öka kapaciteten och förenkla<br />

vid service, t ex avstängningsventiler, injusteringsventiler, filter, silar, 2- eller 3-vägsventiler mm.<br />

- Tänk på rörledningarnas termiska expansion. Montera dem med erforderliga fixeringar och fästdon<br />

som tillåter att de kan expandera och dra ihop sig.<br />

KONDENSVATTENAVLOPP (Vid kyldrift)<br />

Fläktkonvektor<br />

Rörklamma<br />

RÄTT FEL<br />

TÄTHETSPROVNING AV KONDENSVATTENAVLOPPET<br />

Fyll på vatten<br />

Flexibel slang<br />

Kondensvattenledning<br />

• För en bra avrinning bör kondensvattenledningen<br />

luta i strömningsriktningen.<br />

• Undvik bakfall på ledningen.<br />

• Undvik uppåtgående böjar.<br />

• Var försiktig vid inkopplingen av kondensvattenledningen<br />

till enheten så<br />

att anslutningen inte skadas.<br />

• Ytterdiameter för kondensvattenanslutningens<br />

flexibla slang är 20 mm.<br />

• För att förhindra kondensvatten att<br />

droppa från kondensvattenledningen<br />

ska ledningen isoleras med minst<br />

8 mm syntetiskt cellgummi eller<br />

liknande.<br />

• Anslut den inkommande rörledningen<br />

till den flexibla slangen.<br />

• Fyll ledningen från andra änden av<br />

slangen och kontrollera om den läcker.<br />

• När kontrollen är klar ska den flexibla<br />

slangen fästas även på enhetens<br />

kondensvattenanslutning.<br />

OBS! Enheterna har ingen inbyggd pump för kondensvattnet. En separat pump måste<br />

monteras om självfall till ett avlopp ej kan fås för kondensvattenledningen.<br />

51


ELEKTRISKA ANSLUTNINGAR<br />

Nedanstående elschema visar endast ett principiellt förslag till elektrisk inkoppling. Utförandet kan<br />

ändras beroende på typ av vätskekylaggregat, rörsystemets utformning, elektriska föreskrifter, styr-<br />

och reglertekniska orsaker, om det avser kylning eller värmning samt egna önskemål.<br />

Fläktkonvektor 1<br />

COMP L N<br />

3wv<br />

x1<br />

Vätsakekylaggregat<br />

MODELL RCM 20DW - RCM 50DW<br />

Fläktkonvektor 2<br />

COMP L N<br />

3wv<br />

ALLMÄNNA KONTROLLER<br />

x2<br />

52<br />

3wv<br />

Fläktkonvektor 3<br />

COMP L N<br />

3wv<br />

x3<br />

3-vägs magnetventil<br />

x1, x2, x3 Relä (240V, 10A)<br />

Den elektriska inkoppling av en fläktkonvektor måste följa gällande föreskrifter och bestämmelser.<br />

Kontrollera alltid följande punkter:<br />

1) att enheterna är riktigt och säkert infästade och är i rätt läge.<br />

2) att inga läckor finns i anslutningar och rörledningar.<br />

3) att elinst<strong>alla</strong>tionen är utförd enligt gällande föreskrifter.<br />

4) att kondensvattenavrinningen fungerar. Häll lite vatten på droppfatets västra sida och se om det<br />

rinner ut på den högra sidan.<br />

OBSERVERA!<br />

- Dessa anvisningar avser endast de angivna <strong>modeller</strong>na av fläktkonvektorer. För inst<strong>alla</strong>tionen av<br />

vätskekylaggregat, värmesystem mm, hänvisas till gällande anvisningar för de enheterna.<br />

- Inst<strong>alla</strong>tion och inkoppling av enheterna kan variera beroende på valt vätskekylaggregat, värmesystem<br />

och på systemutformningen.<br />

- Inst<strong>alla</strong>tionen ska utföras av kompetenta personer med erfarenhet av denna typ av produkt.<br />

R<br />

S<br />

T<br />

N


FÖRSTA FÖRBEREDELSER<br />

• Den elektriska matningen samt el- / rörinst<strong>alla</strong>tioner ska följa gällande föreskrifter och bestämmelser.<br />

• Spänningen får inte variera mer än ±10% av nominell spänning. Elmatningen får inte innehålla<br />

några svetstransformatorer, eftersom de orsakar stora störningar och ostabilitet i elnätet.<br />

• Montera enheten på en plats som är lämplig för rördragning och elinst<strong>alla</strong>tion.<br />

• Enheten ska monteras så att luften från enheten kan få fritt flöde ut och spridas i rummet, och inte<br />

hindras av belysningsarmaturer, balkar mm. Inte heller returluften in till enheten får hindras.<br />

• Minimimått för fritt utrymme runt en enhet framgår av nedanstående ritning.<br />

• För att förhindra att vibrationer och ljudstörningar ska uppstå, måste underlaget i vilket takkassetten<br />

ska fästas vara så starkt att det klarar en vikt fyra gånger vikten av den enhet som ska monteras.<br />

• Inst<strong>alla</strong>tionsplatsen i undertaket måste vara i våg, och fri höjd ovan undertak måste vara 350 mm<br />

eller mer.<br />

INSTALLATION<br />

INSTALLATION ACK - CW/AW<br />

890 el. 600 mm (öppning i undertak )<br />

790 el. 538 mm<br />

Takkassett 820 mm<br />

Kassett<br />

Takkassett 820 mm<br />

620,5 el. 505 mm (pendlar)<br />

890 el. 600 mm (öppning i undertak )<br />

Pil för riktning av<br />

RÖR-ledningar<br />

Varning<br />

Skarpa kanter och batteriets flänsar utgör potentiell risk för skärskador. Undvik direktkontakt med dem.<br />

Min 1,0 m<br />

Hinder<br />

Max 3,0 m<br />

Golv<br />

Min 0,5 m Min 0,5 m<br />

53<br />

Min 0,5 m<br />

• Enheten ska ej monteras i närheten av aggregat<br />

för uppvärmning (vid kyla) eller befuktning.<br />

Undvik att montera den nära entredörrar.<br />

• Mät och märk ut infästningspunkterna för<br />

pendlarna. Borra hålen för pendlarnas infästningar<br />

i taket och montera pendlarna.<br />

• Inst<strong>alla</strong>tionsmallen kan ändras beroende på<br />

inverkan av temperatur och luftfuktighet.<br />

Kontrollera alltid måtten på plats.<br />

• Måtten på inst<strong>alla</strong>tionsmallen motsvarar den<br />

öppning som krävs för enheten i undertaket.<br />

• Montera inst<strong>alla</strong>tionsmallen för enheten<br />

innan arbetet med undertaket påbörjas.<br />

OBSERVERA! Gå igenom borrningen i taket med <strong>alla</strong> berörda parter innan arbetet påbörjas.<br />

Balk<br />

Max 0,3 m


UPPHÄNGNING<br />

Fläktkonvektor<br />

54<br />

35 mm<br />

Undertaksskiva<br />

• Kontrollera att delningen för upphängningspendlarna är enligt dimensionsritningen.<br />

• Lyft upp enheten och häng den i pendlarna med hjälp av muttrar och brickor.<br />

• Justera höjden mellan enhetens underkant och underkant på undertaket. Måttet ska<br />

vara 35 mm.<br />

• Kontrollera med ett vattenpass eller liknande att takkasetten är monterad i våg.<br />

Dra fast bultar och muttrar för att förhindra att enheten vibrerar och faller ned.<br />

• Öppna upp undertakspanelerna runt den yttre kanten av inst<strong>alla</strong>tionsmallen.<br />

KONDENSVATTENAVLOPP<br />

Fläktkonvektor<br />

Rörklamma<br />

RÄTT FEL<br />

TÄTHETSPROVNING AV KONDENSVATTENAVLOPPET<br />

Fyll på vatten<br />

Flexibel slang<br />

Kondensvattenledning<br />

• För en bra avrinning bör kondensvattenledningen<br />

luta i strömningsriktningen.<br />

• Undvik bakfall på ledningen.<br />

• Undvik uppåtgående böjar.<br />

• Var försiktig vid inkopplingen av kondensvattenledningen<br />

till enheten så<br />

att anslutningen inte skadas.<br />

• Ytterdiameter för kondensvattenanslutningens<br />

flexibla slang är 20 mm.<br />

• För att förhindra kondensvatten att<br />

droppa från kondensvattenledningen<br />

ska ledningen isoleras med minst<br />

8 mm syntetiskt cellgummi eller<br />

liknande.<br />

• Anslut den inkommande rörledningen<br />

till den flexibla slangen.<br />

• Fyll ledningen från andra änden av<br />

slangen och kontrollera om den läcker.<br />

• När kontrollen är klar ska den flexibla<br />

slangen fästas även på enhetens<br />

kondensvattenanslutning.<br />

OBS! Enheterna har en inbyggd pump för kondensvattnet. Installera enheterna i våg<br />

för att förhindra kondensvattenläckage och kondens runt utblåsningsgallret.


INSTALLATION AV FRONTPANELEN<br />

• Frontpanelens ram kan monteras endast i en riktning som bestäms utifrån riktningen på rörledningarnas<br />

anslutning. På frontpanelens ram sitter en skylt med en pil som indikerar rörens<br />

riktning i förhållande till ramen.<br />

• Ta bort inst<strong>alla</strong>tionsmallen innan frontpanelen monteras.<br />

• Öppna returluftgallret genom att dra spärrhakarna bakåt. Ta bort gallret och luftfiltret från<br />

ramen.<br />

• Montera fronpanelens ram på enheten med fyra skruvar. Se till att anslutningen blir tät så<br />

att inget luftläckage uppstår.<br />

• Anslut kontrollkabeln och kabeln från luftriktarnas motor till enheten.<br />

Från<br />

frontpanelen<br />

ÖPPNA<br />

OBS! Var noga med att det blir en tät anslutning mellan enheten och frontpanelen. Luftläckage<br />

kan leda till kondens med droppande vatten samt störande ljud som följd.<br />

Tilluft<br />

Kontrollkabel<br />

Kabel till<br />

luftriktarnas motor<br />

Aggregat<br />

Undertaksskiva<br />

Frontpanel<br />

55<br />

Luftläckage<br />

Kontrollpanel<br />

Tilluft<br />

RÄTT FEL<br />

SKRUVAR<br />

Luftläckage<br />

Undertaksskiva<br />

Frontpanel


RETURLUFTGALLER<br />

• Se till att luftfiltret är riktigt fastsatt i returluftgallret<br />

innan gallret monteras.<br />

• Sätt fast returluftgallret och dess filter i frontpanelens<br />

ram.<br />

• Returluftgallret kan monteras i valfri riktning.<br />

När det monteras bör man ta hänsyn till<br />

undertakets utformning och gallrets funktion.<br />

• Om enheten ska utrustas med ett joniseringsfilter<br />

(extra tillbehör), måste detta filter<br />

monteras på luftfiltret innan gallret monteras.<br />

• Fäst joniseringsfiltret på luftfiltret med den<br />

svarta sidan uppåt och den vita sidan nedåt.<br />

• Sätt försiktigt fast joniseringsfiltrets filterram.<br />

FILTERRAM<br />

(TILLBEHÖR)<br />

JONISERINGSFILTER<br />

(TILLBEHÖR)<br />

LUFTFILTER<br />

(STANDARD)<br />

VENTILATIONSKANALER<br />

Enheterna är försedda med "knock-out" hål för anslutning av korta kanaler för intags- och utblåsningsluft.<br />

Observera att anslutningen av en kanal för utblåsningsluften är möjlig endast på ena sidan.<br />

Användning av en extra kanal med ett tilluftdon för utblåsningsluften förbättrar luftdistributionen när<br />

det finns ett hinder (t ex en belysningsarmatur) i vägen, eller i ett avlångt eller L-format rum. De kan<br />

också användas för att samtidigt betjäna två rum.<br />

Möjliga riktningar för anslutning av kanaler för intags- och utblåsningsluft<br />

Utblåsningsluft<br />

Luftintag<br />

Utblåsningsluft Utblåsningsluft<br />

Dimensioner på "knock-out" öppningar<br />

119 90<br />

10 50 50 50 50 50 10<br />

115 20 115<br />

20<br />

70<br />

20<br />

109<br />

Utblåsningsluft<br />

"Knock-out" öppningar för utblåsningsluft "Knock-out" öppning för intagsluft<br />

SÄTTA IGEN EN UTBLÅSNINGSÖPPNING<br />

Ø100<br />

Ø140<br />

Observera!<br />

• Kanalerna måste vara täta så att<br />

inget luftläckage uppstår.<br />

• För att undvika att kondens bildas<br />

på kanalen för inblåsningsluft<br />

måste kanalen isoleras.<br />

• Håll inblandningen av uteluft under<br />

20% av totala luftmängden.<br />

Det är nödvändigt att installera<br />

en hjälpfläkt för uteluften.<br />

- Det är möjligt att sätta igen en av de fyra utblåsningsöppningarna. Fler igensatta öppningar kan orsaka en<br />

dålig funktion. Demontera frontpanelen och sätt fast tätningsmaterialet i den öppning som ska sättas igen.<br />

- Om den korta öppningen ska sättas igen kan tätningsmaterialet kapas till lämplig längd.<br />

- Skjut in tätningsmaterialet ca 10 mm bakom undersidan av enheten, så att det inte kommer i kontakt med<br />

gallret. Var noga med att inte skjuta in tätningsmaterialet längre in än ca 10 mm.<br />

56


ANSLUTNING AV KÖLD- ELLER VÄRMEBÄRARLEDNINGAR<br />

- Fläktkonvektorn är försedd med oisolerade anslutningar för in- och utgående rörledningar. På batteriets<br />

högsta punkt finns en avluftningsventil monterad. Tryck på ventilen för att avlufta batteriet.<br />

- En 3-vägs magnetventil eller reglerventil krävs för att stänga av eller reglera vätskeflödet till enheten.<br />

- Svarta stålrör, kopparrör, PVC-rör eller polyetenrör kan användas. Material måste väljas med hänsyn<br />

till typ av vätska mm.<br />

- Alla köldbärarledningar och anslutningar måste isoleras mot kondens med syntetiskt cellgummi typ<br />

Armaflex eller liknande.<br />

- Använd ej invändigt nedsmutsade rör eller skadade rör och rördelar till inst<strong>alla</strong>tionen.<br />

- Vissa huvudkomponeneter är nödvändiga att montera i rörsystemet för en god funktion och för att förenkla<br />

vid service, t ex avstängningsventiler, injusteringsventiler, filter, silar, 2- eller 3-vägsventiler mm.<br />

- Tänk på rörledningarnas termiska expansion. Montera dem med erforderliga fixeringar och fästdon<br />

som tillåter att de kan expandera och dra ihop sig.<br />

ELEKTRISKA ANSLUTNINGAR<br />

Nedanstående elschema visar endast ett principiellt förslag till elektrisk inkoppling. Utförandet kan<br />

ändras beroende på typ av vätskekylaggregat, rörsystemets utformning, elektriska föreskrifter, styroch<br />

reglertekniska orsaker, om det avser kylning eller värmning samt egna önskemål.<br />

Fläktkonvektor 1<br />

COMP L N<br />

3wv<br />

x1<br />

Vätsakekylaggregat<br />

MODELL ACK 20AW - ACK 50AW<br />

Fläktkonvektor 2<br />

COMP L N<br />

3wv<br />

ALLMÄNNA KONTROLLER<br />

x2<br />

3wv 3-vägs magnetventil<br />

x1, x2, x3 Relä (240V, 10A)<br />

57<br />

Fläktkonvektor 3<br />

COMP L N<br />

Den elektriska inkoppling av en fläktkonvektor måste följa gällande föreskrifter och bestämmelser.<br />

Kontrollera alltid följande punkter:<br />

1) att fläktkonvektorerna är riktigt och säkert infästade och är i rätt läge.<br />

2) att inga läckor finns i anslutningar och rörledningar.<br />

3) att elinst<strong>alla</strong>tionen är utförd enligt gällande föreskrifter.<br />

4) att kondensvattenavrinningen fungerar. Häll lite vatten på droppfatets västra sida och se om det<br />

rinner ut på den högra sidan.<br />

OBSERVERA!<br />

- Dessa anvisningar avser endast de angivna <strong>modeller</strong>na av fläktkonvektorer. För inst<strong>alla</strong>tionen av<br />

vätskekylaggregat, värmesystem mm, hänvisas till gällande anvisningar för de enheterna.<br />

- Inst<strong>alla</strong>tion och inkoppling av enheterna kan variera beroende på valt vätskekylaggregat, värmesystem<br />

och på systemutformningen.<br />

- Inst<strong>alla</strong>tionen ska utföras av kompetenta personer med erfarenhet av denna typ av produkt.<br />

3wv<br />

x3<br />

R<br />

S T<br />

N


Inomhusdel<br />

INSTALLATION ACC - CW<br />

Vattenledningar<br />

INSTALLATION AV INOMHUSDELEN<br />

- Den elektriska matningen samt el- och rörinst<strong>alla</strong>tioner ska följa gällande föreskrifter och bestämmelser.<br />

- Enheten ska monteras så att luften ifrån enheten kan få fritt flöde ut och spridas i rummet, och inte hindras<br />

av belysningsarmaturer, balkar mm. Inte heller returluften in till enheten får hindras.<br />

- Använd medföljande upphängnings-konsoler vid montaget.<br />

- Försäkra dig om att taket är starkt nog att upprätthålla aggregatets vikt.<br />

Center mått för upphängning. Montera enligt anvisning för optimalt luftflöde och<br />

utrymme för service.<br />

58<br />

Chiller<br />

CHILLER<br />

ACC 10CW 15CW 20CW 25CW 28CW 30CW 38CW 40CW 50CW 60CW<br />

A (mm) 741 881 1041 1176 959 956 1264 1076 1326 1526<br />

L (mm) 225 225 225 225 339 266 401 266 266 266<br />

ELEKTRISKA ANSLUTNINGAR<br />

AC C 10C W - AC C 25C W<br />

MODELL C C 10C W C C 15C W C C 20C W C C 25C W<br />

Spänningsområde 220V - 240V / 1Ph / 50Hz + ! or 208V - 230V / 1Ph / 60Hz + !<br />

Rekommenderad avsäkring A 10 10 10 10<br />

Kabeldimension matning mm 2 1.5 1.5 1.5 2.5<br />

Antal kardeler 3 3 3 3<br />

Kabeldimension manöver mm 2 1.5 1.5 1.5 1.5<br />

Antal kardeler 3 3 3 3<br />

10 mm<br />

10 mm<br />

E nglish


AC C 28C W - AC C 60C W<br />

MODELL C C 28 / 30C W C C 38 / 40 C W C C 50C W C C 60C W<br />

Spänningsområde 220V - 240V / 1Ph / 50Hz + ! or 208V - 230V / 1Ph / 60Hz + !<br />

Rekommenderad avsäkring A 16 16 16 16<br />

Kabeldimension matning mm 2 2.5 2.5 2.5 2.5<br />

Antal kardeler 3 3 3 3<br />

Kabeldimension manöver mm 2 1.5 1.5 1.5 1.5<br />

Antal kardeler 3 3 3 3<br />

VIKTIGT: Tabellen är rekommendationer ifrån leverantören. I första hand så ska nationella<br />

och lokala regler och rekommendationer följas.<br />

C hiller<br />

Gate Valve<br />

RÖRANSLUTNINGAR<br />

- Fläktkonvektorn är försedd med oisolerade anslutningar för in- och utgående rörledningar. På batteriets högsta punkt<br />

finns en avluftningsventil monterad. Tryck på ventilen för att avlufta batteriet.<br />

- En 3-vägs magnetventil eller reglerventil krävs för att stänga av eller reglera vätskeflödet till enheten.<br />

- Svarta stålrör, kopparrör, PVC-rör eller polyetenrör kan användas. Material måste väljas med hänsyn till typ av vätska mm.<br />

- Alla köldbärarledningar och anslutningar måste isoleras mot kondens med syntetiskt cellgummi typ armaflex eller liknande.<br />

- Använd ej invändigt nedsmutsade rör eller skadade rör och rördelar till inst<strong>alla</strong>tionen.<br />

- Vissa huvudkomponeneter är nödvändiga att montera i rörsystemet för en god funktion och för att förenkla vid service,<br />

t ex avstängningsventiler, injusteringsventiler, filter, silar, 2- eller 3-vägsventiler mm.<br />

Gate Valve Three Way Valve<br />

FCU<br />

59<br />

Gate Valve<br />

Gate Valve<br />

Two Way Valve<br />

FCU<br />

Gate Valve<br />

Gate Valve<br />

G ood C ontrolling B ad C ontrolling Worst C ontrolling<br />

ELEKTRISKA ANSLUTNINGAR<br />

FCU 1 FCU 2 FCU 3<br />

FL FM FH TH COMP L N FL FM FH TH COMP L N FL FM FH TH COMP L N<br />

x1<br />

C C 10C W ~C C 25C W (without controller)<br />

TH TH<br />

3wv<br />

3wv<br />

x2<br />

C hiller<br />

3wv<br />

x3<br />

TH<br />

3wv<br />

x1, x2, x3 R elay (220-240V, 10A)<br />

TH Thermostat<br />

S<br />

R<br />

T<br />

S olenoid Valve for 3 way valve<br />

N<br />

FCU


COMP L N<br />

3wv<br />

FCU 1<br />

C hiller<br />

x1<br />

C C 10C W ~C C 25C W (with netware-1 controller)<br />

COMP L N<br />

3wv<br />

FCU 2<br />

x2<br />

60<br />

3wv<br />

FCU 3<br />

COMP L N<br />

3wv<br />

x3<br />

S olenoid Valve for 3 way valve<br />

x1, x2, x3 R elay (220-240V, 10A)<br />

R<br />

S T<br />

N


8. Fjärrkontroll<br />

Rätt fjärrkontroll till rätt fancoil<br />

MODELL STANDARD CONTROLLER OPTIONAL CONTROLLER<br />

AWM - GW G12 (Wireless) NETWARE3 / SLM3 (Wired)<br />

AWM 301W G8 (Wireless) NETWARE3 / SLM3 (Wired)<br />

ACK - AW / BW / CW / AWH G8 (Wireless) NETWARE3 / SLM3 (Wired)<br />

ACM - DW / CBW / EW G8 (Wireless) NETWARE3 / SLM3 (Wired)<br />

ACC - CW NETWARE3 / SLM3 (Wired) -<br />

ADB - BW Without Controller<br />

Felindikering ifrån aggregat<br />

Error Indication Cool LED 7 Segment Display<br />

Room Sensor error (short/open) Blinks 1 times E1<br />

Pipe Water Sensor Error (short/open) Blinks 2 times E2<br />

Water Pump Error Blinks 6 times E6<br />

Pipe Water Temperature Fault Blinks 5 times E5<br />

* Window Open Activated Blinks 3 times -<br />

* Antifreeze Mode Activated Blinks 7 times -<br />

* Load Shedding Activated Blinks 8 times -<br />

* Only applicable for 4-pipe system<br />

61


4<br />

6<br />

10<br />

8<br />

Part Nr.: A08019013163<br />

Trådlös fjärrkontroll - modell G8<br />

AM<br />

PM<br />

SWING<br />

AUTO<br />

CLOCK<br />

ON<br />

OFF<br />

62<br />

MIN<br />

HR FC<br />

ON TIMER SET CLR<br />

SET CLR<br />

OFF TIMER<br />

MODE<br />

SLEEP<br />

1<br />

2<br />

3<br />

7<br />

5<br />

9<br />

11<br />

12


FUNKTIONER<br />

1. Transmitter (sändare)<br />

• Sänder signalerna till den enhet som ska styras.<br />

2. Indikering av transmission<br />

• Indikerar med en blinkning att det senaste kommandot har sänts till enheten.<br />

3. Till / Från<br />

• Tryck en gång för att starta en enhet.<br />

• Tryck en gång till för att stoppa den.<br />

4. Temperaturinställning<br />

• Tryck på ▲ för att öka inställningsvärdet och på ▼ för att minska inställningsvärdet för den önskade<br />

rumstemperaturen.<br />

• Inställningsområdet för rumstemperaturen är 16°C till 30°C. (En specialvariant har 18°C till 30°C.)<br />

• Tryck samtidigt på de båda knapparna ▲ och ▼ för att växla temperaturvisningen mellan °C och °F.<br />

5. Arbetssätt<br />

• Tryck på knappen MODE för att välja ett av följande arbetssätt för en enhet:<br />

- Luftkonditioneringsenheter: COOL (kyla), DRY (avfuktning) och FAN (fläkt).<br />

- Värmepumpar: AUTO, COOL (kyla), DRY (avfuktning) , FAN (fläkt) och HEAT (värme).<br />

6. Inställning av fläktvarvtal<br />

• Håll knappen oavbrutet intryckt, varvid fläkthastigheterna bläddras fram i följande ordning:<br />

Low (låg) –––: Med (mellan) –––: High (hög) –––: Auto<br />

• Släpp knappen när det önskade alternativet visas i displayen.<br />

7. Turbo-funktion (extra tillbehör)<br />

• Tryck på knappen för en snabb nedkylning eller en snabb uppvärmning (endast värmepumpar).<br />

• Rumstemperaturen kommer att sjunka om enhetens arbetssätt är COOL (kyla) eller DRY (avfuktning)<br />

alternativt att öka om enhetens arbetssätt är HEAT (värme).<br />

Fläkten kommer att öka till högsta hastighet, om hastigheten inte redan är den högsta.<br />

• Temperatur och fläkt återgår till inställda värden efter 20 minuter eller om man trycker på igen.<br />

• Funktionen fungerar endast i arbetssätten COOL (kyla), DRY (avfuktning) och HEAT (värme).<br />

8. Timerfunktion - Tillslag<br />

• Tryck på SET på knappen ON TIMER för att aktivera enhetens funktion för automatiskt tillslag.<br />

• Ställ in tidpunkten för tillslaget genom att hålla knappen SET intryckt tills önskat klockslag visas.<br />

AM innebär klockslag mellan 00.00 - 12.00 och PM innebär klockslag mellan 12.00 - 24.00.<br />

• Tryck på CLR på knappen ON TIMER för att deaktivera den automatiska tillslagsfunktionen.<br />

9. Timerfunktion - Frånslag<br />

• Tryck på SET på knappen OFF TIMER för att aktivera enhetens funktion för automatiskt frånslag.<br />

• Ställ in tidpunkten för frånslaget genom att hålla knappen SET intryckt tills önskat klockslag visas.<br />

• Tryck på CLR på knappen OFF TIMER för att deaktivera den automatiska frånslagsfunktionen.<br />

10. Automatiska rörliga luftriktare (extra tillbehör)<br />

• Tryck på knappen SWING för att starta de rörliga luftriktarna.<br />

• Om man önskar att ha de rörliga luftriktarna stående i ett speciellt läge, väntar man tills de kommer<br />

dit och trycker ännu en gång på knappen varvid de stannar.<br />

11. Nattändring av temperaturen<br />

• Tryck på knappen SLEEP för att aktivera nattändringsfunktionen.<br />

• Detta är en energibesparande funktion. När en enhet är i kyldrift<br />

kommer den inställda rumstemperaturen öka med 0,5°C efter en<br />

halvtimme, öka med 1°C efter en timme och öka med 2°C efter<br />

två timmar. Denna funktion gör att ett rum inte kyls ner i onödan<br />

när det inte används.<br />

• När en värmepump är i värmedrift kommer inställd rumstemperatur<br />

att sänkas med 0,5°C efter en halvtimme, sänkas med 1°C efter<br />

en timme och sänkas med 2°C efter två timmar. Denna funktion<br />

gör att ett rum inte värms upp i onödan när det inte används.<br />

• Nattändringsfunktionen kopplas bort genom att trycka ännu en gång på knappen SLEEP.<br />

12. Ställa klockan<br />

• Tryck på + vid knappen CLOCK för att ändra klockans visade tid framåt.<br />

• Tryck på - vid knappen CLOCK för att ändra klockans visade tid bakåt.<br />

63<br />

+2 C<br />

+1 C<br />

- 1 C<br />

- 2 C<br />

0 0.5 1 1.5 2


FASTSÄTTNING I HÅLLAREN<br />

• Sätt upp fjärrkontrollens hållare på väggen med hjälp av de medföljande skruvarna.<br />

Hållaren bör om möjligt placeras så att enheten kan ta emot signalerna från<br />

fjärrkontrollen.<br />

• Fjärrkontrollen placeras i hållaren genom att placera den ovanför hållaren och<br />

sedan skjuta ner den.<br />

• Fjärrkontrollen tas ur hållaren<br />

genom att dra den rakt upp.<br />

AM<br />

PM<br />

AUTO<br />

ON<br />

OFF<br />

MIN<br />

HR FC<br />

SÄTTA I BATTERIER<br />

• Ta bort bakre locket genom att trycka ned det vid pilen och dra i pilens riktning.<br />

• Sätt i två batterier. Försäkra er om att riktningen på polerna + och – blir de rätta.<br />

• Sätt tillbaka locket och kontrollera displayen.<br />

Ta ur batterierna och sätt i dem igen om displayen<br />

inte skulle tändas. Hjälper inte det - byt batterier.<br />

OBSERVERA! Om displayen lyser svagt, eller<br />

om en enhet inte tar emot de<br />

skickade signalerna, måste<br />

batterierna bytas.<br />

64<br />

AM<br />

PM<br />

AUTO<br />

ON<br />

OFF<br />

MIN<br />

HR FC


3<br />

8<br />

14<br />

6<br />

7<br />

G12 Fjärrkontroll<br />

Key Function Actions<br />

RECALL PRESS ONCE for P1 & TWICE FOR P2<br />

PRESS & HOLD BUTTON for 3s to<br />

INITATE PERSONALISED SETTING<br />

PROGRAM<br />

SELECT P1 OR P2<br />

SET INDIVIDUAL SETTINGS eg.<br />

MODE, SET TEMP or FAN SPEED<br />

LEAVE for 4s to SAVE<br />

REAL TIME<br />

CLOCK CLOCK<br />

(RTC)<br />

PRESS & HOLD BUTTON for 2s to<br />

ACTIVATE<br />

PRESS '+' or '-' to DESIRED TIME<br />

LEAVE for 4s to SAVE<br />

1<br />

2<br />

4<br />

13<br />

9<br />

12<br />

11<br />

5<br />

10<br />

Part No.: A08019020512 OM-G12-0104


BESKRIVNING<br />

1. Transmitter.<br />

Överför inställda eller ändrade data till innedelen.<br />

2. Indikering av sändning.<br />

Blinkar för att bekräfta att data sänts till innedelen.<br />

3. ON / OFF Knapp.<br />

Tryck en gång för att starta aggregatet.<br />

Tryck igen för att stoppa aggregatet.<br />

4. Temperaturinställning.<br />

För att öka inställningsvärdet på den önskade rumstemperatruren trycker<br />

man på den uppåtriktade pilen och för att minska inställningsvärdet<br />

trycker man på den nedåtriktade pilen.<br />

Inställningsområdet är 16°C till 30°C. (Vissa specialvarianter har<br />

inställningsområde 20°C till 30°C.)<br />

Tryck in båda piltangenterna samtidigt för att ändra från °C till °F.<br />

5. Arbetssätt<br />

Tryck på knappen MODE för att välja ett av följande arbetsätt för<br />

aggregatet.<br />

COOL: I detta läge startar aggregatet i kyldrift, kompressorn startas<br />

och stoppas med termostatfunktionen.<br />

DRY: Vid hög luftfuktighet kan detta läge användas för att torka luften .<br />

Så länge rumstemperaturen är mer än två grader över<br />

termostatfunktionen inställda börvärde kommer aggregatet<br />

fungera som i arbetsätt COOL. När rumstemperaturen är mindre<br />

än två grader över börvärdet träder arbetsätt DRY i funktion. I<br />

detta arbetsätt kommer inomhusdelens fläkt alltid att vara i drift<br />

på lägsta hastighet. Kompressorns drift styrs av<br />

termostatfuntionen.<br />

FAN: I detta läge är endast inomhusdelens fläkt i drift.<br />

6. Fläkthastigheter<br />

Genom att trycka på knappen FAN kommer fläkthastigheterna att<br />

ändras i följande ordning:<br />

Low (Låg) - Med (Mellan) - High (Hög) - Auto<br />

Stoppa knapptryckning när önskat alternativ visas i displayen.<br />

66


7. Turbo<br />

Temperatur och fläkt återgår till inställda värden efter 20 minuter eller om<br />

man trycker påknappen ännu en gång. Funktionen fungerar i arbetssätten<br />

COOL (kyla) och DRY (avfuktning). Tryck på knappen för en snabb nedkylning.<br />

Fläkten kommer att öka till högsta hastighet, om hastigheten inte redan är<br />

den högsta.<br />

8. Timerfunktion tillslag<br />

Tryck på SET på knappen ON TIMER för att aktivera funktionen för<br />

automatiskt tillslag. Ställ in tidpunkten för tillslaget genom att hålla SET<br />

intryckt tills önskat klockslag visas. AM innebär klockslag mellan 00.00 -<br />

12.00 och PM klockslag mellan 12.00 - 24.00. Tryck på CLR på knappen CLR<br />

för att deaktivera den automatiska tillslagsfunktionen.<br />

9. Timerfunktion frånslag<br />

Tryck på SET på knappen OFF TIMER för att aktivera funktionen för<br />

automatiskt frånslag.Ställ in tidpunkten för tillslaget genom att hålla SET<br />

intryckt tills önskat klockslag visas.AM innebär klockslag mellan 00.00 -<br />

12.00 och PM klockslag mellan 12.00 - 24.00.Tryck på CLR på knappen för<br />

att deaktivera den automatiska funktionen.<br />

10. Automatisk rörliga luftriktare (tillbehör)<br />

Tryck på knappen SWING för att starta de rörliga luftriktarna. Om man<br />

önskar att ha de rörliga luftriktarna stående i ett speciellt läge, väntar man<br />

tills de kommer dit och trycker ännu en gång på knappen SWING varvid de<br />

stannar.<br />

11. Nattändring av temperaturen (SLEEP) +2 C<br />

Tryck på knappen SLEEP för att aktivera<br />

+1 C<br />

nattändringsfunktionen.<br />

Detta är en energibesparande funktion. När<br />

aggregatet är i arbetsätt COOL kommer den - 1 C<br />

inställda rumstemperaturen att öka med<br />

- 2 C<br />

0,5°C efter en halvtimme. öka med 1°C efter<br />

67<br />

0 0.5 1 1.5 2<br />

12. Ställa klockan<br />

Tryck på + eller - på knappen CLOCK för att ändra<br />

klockans inställning.<br />

13. Personlig inställning<br />

Håll knappen intryckt i 3 sekunder, symbolen kommer då att blinka, vid<br />

ytterligare tryckning växlar visning att växla mellan och .<br />

Ställ sedan in önskad inställning med fjärrkontrollen och lämna kontrollen i<br />

4 sekunder för att spara inställningen. Tryck en gång på för att aktivera<br />

inställning P1, ytterligare en gång för att växla mellan P1 och P2


MONTERING PÅ VÄGG<br />

INSTALLATION AV<br />

BATTERIER


NETWARE 3 trådbunden fjärrkontroll<br />

Display<br />

D<br />

F<br />

H<br />

A : Fläkthastighet<br />

· Visar vilken fläkthastighet som är vald (Auto, high,medium eller low).<br />

B : Driftläge<br />

· Visar vilket driftläge som är valt (Auto, dry, cool, heat eller fan).<br />

C : Sleep funktionen<br />

· Visar om sleep funktionen är aktiverad.<br />

D : Felmeddelande<br />

· Visar error vid fel.<br />

E : Swing funktionen<br />

· Visar när swing funktionen är aktiv.<br />

F : Knapplås<br />

· Visar key lock när knapplåset är aktiverat.<br />

G : °C eller °F<br />

· Visar om temperaturen mäts i °C eller °F.<br />

H : Klockan och ON/OFF-tider<br />

· Visar vad klockan är och inställda ON/OFF-tider.<br />

I : On / Off Status<br />

· Lampa visar ON eller OFF status<br />

J : Rumstemperatur eller inställt börvärde<br />

· Visar rumstemperatur eller inställt börvärde.<br />

Andra funktioner<br />

· Batteri back up för att spara senaste inställningar vid strömavbrott.<br />

För 7-dagars programmvara, används batteri back up för att spara senast inställda värden.<br />

I kontroller utan batteri back up så sparas senast inställda värdei E-promet på aggregatet kretskort.<br />

· Larm<br />

Visar fel kod om ett fel uppstår. Se innedelens felkoder.<br />

A B C<br />

69<br />

E<br />

G<br />

J<br />

I


O<br />

P<br />

Q<br />

Funktion<br />

° °<br />

°<br />

K : Driftlampa<br />

L:On/Off<br />

• Starta :<br />

Om aggregatet är avstängt, tryck på ON/OFF-knappen. Driftlampan tänds och aggregatet startar.<br />

• Stoppa :<br />

Om aggregatet är i drift, tryck på ON/OFF-knappen. Driftlampan slocknar och aggregatet stoppar.<br />

M : Ställa in börvärde<br />

• Tryck på pil upp knappen för att ställa in önskad rumstemperatur. Genom att trycka på upp eller nerpil<br />

en gång ändras värdet 1°C (eller 1°F).<br />

• Temperaturområdet är 16 - 30°C (eller 60 - 85°F).<br />

• I fläktdrift kan inte temperaturen ställas in.<br />

• Tryck in upp och ner-pil samtidigt för att skifta mellan °C och °F. .<br />

• När set temp knappen trycks ner visas inställt börvärde i 5 sekunder och återgår sen för att visa<br />

rumstemperaturen.<br />

N : Driftval<br />

• Tryck på MODE knappen för att välja mellan cool, heat, dry och fan. I displayen visas vilken<br />

drift som är vald.<br />

O : Fläkthastighet<br />

• Tryck på FAN knappen för att välja fläkthastighet mellan auto, high, medium och low.<br />

P : Swing funktionen<br />

• Tryck på swing knappen för att köra luftrikaren i en svepande rörelse.<br />

Q : Sleep funktionen<br />

• Tryck på sleep knappen för att aktivera sleep funktionen och spara energi.<br />

70<br />

K<br />

N<br />

L<br />

M


S<br />

R<br />

X<br />

Z<br />

Y<br />

R : Timer active<br />

S : Visar aktuell tid<br />

T : Driftslampa<br />

U : Knapplås<br />

• Denna funktion hindrar att barn eller obehöriga ändrar inställningar.<br />

• För att aktivera knapplåset tryck 3 gånger på MINUTE knappen. Nu visas KEY LOCK i<br />

displayen.<br />

• Även om knapplåset är aktiverat så kan ON/OFF och FAN knapparna användas.<br />

• För att avaktivera knapplåset, tryck 3 gånger på MINUTE knappen.<br />

V : Minute<br />

• När kontrollen står i SET CLOCK eller SET TIMER, tryck på MINUTE knappen för att ändra<br />

minuter.<br />

W : Hour<br />

• När kontrollen står i SET CLOCK eller SET TIMER, tryck på HOUR knappen för att ändra<br />

timmar.<br />

X : Day<br />

• När kontrollen står i SET CLOCK eller SET TIMER, tryck på DAY knappen för att ändra dagar.<br />

Y : Clock<br />

• Tryck på CLOCK knappen för aktivera klockinställning, CLOCK SET visas i displayen.<br />

• Tryck en gång till för att avaktivera klockinställningen.<br />

• När klockinställningen är aktiverad så kan du ändra tid och dag genom att trycka på DAY, HOUR<br />

och MINUTE knapparna.<br />

Z : Aktivera timer<br />

• Om 7 dagars timer är inställt, så kommer TIMER ACTIVE visas i displayen.<br />

• För att ta bort timer inställningen, tryck in HOLD knappen i 2-3 sekunder till TIMER ACTIVE<br />

försvinner från displayen.<br />

• För att återuppta timer inställningarna, tryck in HOLD knappen i 2-3 sekunder till TIMER ACTIVE<br />

visas i displayen.<br />

71<br />

T<br />

W<br />

U<br />

V


SLM3 trådbunden fjärrkontroll<br />

8<br />

9<br />

2<br />

5<br />

1. “ON/OFF” knapp<br />

• Tryck på ON/OFF för att starta aggregatet.<br />

• Tryck igen för att stoppa aggregatet.<br />

2. Börvärdes inställning<br />

• Ställer in önskad rumstemperatur.<br />

• Tryck på pil knapparna för att öka eller sänka<br />

börvärdet. Temperaturområde är 16 - 30 °C<br />

(60-85°F).<br />

3. driftval<br />

• Tryck på MODE knappen för att välja<br />

driftsätt.<br />

- Endast luftkonditionering:<br />

COOL, FAN, DRY<br />

- Värmepump:<br />

COOL, FAN, DRY, HEAT<br />

TEMP<br />

TIMER<br />

4. Fläkthastighet<br />

• Tryck på FAN knappen till önskad fläkthastighet<br />

är vald.<br />

5. Timer.<br />

• Tryck på TIMER knappen för att välja efter hur<br />

många timmars drift aggregatet ska slå av (inom<br />

området 1-15 timmar).<br />

AUTO<br />

HIGH<br />

MED<br />

LOW<br />

SENSOR<br />

COOL<br />

DRY FAN<br />

FAN<br />

HEAT DRY<br />

HEAT<br />

FAN<br />

SWING<br />

SLM3<br />

ON/OFF<br />

MODE<br />

SLEEP<br />

72<br />

4<br />

1<br />

3<br />

6<br />

7<br />

4<br />

7<br />

5<br />

FAN ON/OFF<br />

SWING<br />

TEMP<br />

SLEEP<br />

TIMER MODE<br />

AC5300 (TILLVAL)<br />

6. “Sleep” funktionen<br />

• Tryck på SLEEP knappen för att aktivera<br />

funktionen. Sleep funktionen kan endast<br />

aktiveras i kyla eller värme-drift(COOL eller<br />

HEAT-mode). När den aktiveras i kyldrift så<br />

ökar den inställda temperaturen 0,5°C efter<br />

30 minuter, 1 °C efter 1 timmeoch 2 °C efter<br />

2 timmar.<br />

Om sleep funktionen aktiveras under värmedrift<br />

så sjunker den inställda temperaturen0,5°C efter<br />

30 minuter, 1 °C efter 1 timmeoch 2 °C efter<br />

2 timmar.<br />

7. Svep funktionen<br />

• Tryck på SWING knappen för aktivera den<br />

automatiska svep funktionen.<br />

8. Sensor<br />

• IR-mottagare för att ta imot signal från<br />

trådlös fjärrkontroll.<br />

9. Display<br />

• För visning av inställd temperatur (i °C)<br />

och timer inställningen (i timmar)<br />

10. IR-transmitter<br />

• Skickar signal till aggregatet.<br />

10<br />

1<br />

2<br />

6<br />

3


INSTALLATION AV LCD FJÄRRKONTROLL<br />

STEG FÖR STEG GUIDE<br />

i) Använd en skruvmejsel och öppna LCD fjärrkontrollens hölje, så att du har en underdel och en överdel.<br />

För att göra detta, trycker du in skruvmejselen i springan i underkanten och drar försiktigt utåt.<br />

ii) Skruva fast underdelen i väggen med de två medföljande skruvarna. Stick sedan in fyrledaren (från<br />

aggregatet) genom hålet i underdelen, som visas här nedan.<br />

iii) Koppla in de tre trådarna på överdelens plintar på baksidan.<br />

iv) Välj endast kyla eller värmepump genom att ställa in switcharna.<br />

v) Sätt tillbaka överdelen på underdelen genom att haka i de två hakarna i överkant, vik ner överdelen<br />

och "klicka" på den i underkant.<br />

Springa i underkant<br />

för att kunna skilja<br />

över- och underdel<br />

Inkoppling på<br />

överdelens baksida.<br />

Inställning av switchar för val av drift.<br />

2 x skruv<br />

LCD Fjärrkontroll<br />

(överdel)<br />

SWITCH FUNKTION INSTÄLLNING<br />

JH & JD RESERV JH-OFF, JD-OFF<br />

COOL, DRY, FAN JH-OFF, JD-ON<br />

COOL, DRY, FAN, HEAT JH-ON, JD-OFF<br />

RTC INGEN REALTIDS-KLOCKA RTC-OFF<br />

REALTIDS-KLOCKA RTC-ON<br />

NO DRY INGEN DRY FUNKTION NO DRY-ON<br />

DRY FUNCTION NO DRY-OFF<br />

73<br />

LCD fjärrkontroll<br />

undersida<br />

Koppling till<br />

aggregat<br />

Kabel

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!