Table 7: Study No. 14-VIN-657– outcome of validation of the analytical methods<br />

Parameter Acceptance criterion Found value acceptable<br />

(yes/no)<br />

Selectivity<br />

6 individual sources,<br />

14 lots, no significant yes<br />

response is LLOQ – ULOQ<br />

≥5 samples at ≥4 concentration levels<br />

each,<br />

±20% for LLOQ<br />

±15% for >LLOQ – ULOQ<br />

≥5 samples at ≥4 concentration levels<br />

each,<br />

±20% for LLOQ<br />

±15% for >LLOQ – ULOQ<br />

Accuracy and precision should be within<br />

the set criteria, i.e. within ±15%<br />

normalized MF calculated from the 6 lots<br />

of matrix ≤15 % for low and high<br />

concentration level<br />

Low, medium, high<br />

QC within ±15%<br />

Low, medium, high<br />

QC within ±15%<br />

Low, medium, high<br />

QC within ±15%<br />

Low, medium, high<br />

QC within ±15%<br />

Dilution factor 2 & 4;<br />

complies<br />

6 lots, no significant<br />

matrix effect<br />

Carry over response is