8. Disassemble the vacuum relief valve (D).<br />
Clean and lubricate shaft and bearings.<br />
Check the rubber gasket (E). Change if<br />
cracked or harden (Part No. 4710).<br />
Check the function of the hydraulic<br />
damper (F).<br />
E<br />
D<br />
Adjusting the vacuum relief valve<br />
The valve is pre-adjusted with a negative pressure<br />
(18 kPa). If this is to be adjusted the following<br />
procedure is used:<br />
- Connect a manometer to the suction side and<br />
measure with fully closed inlet.<br />
- Shut down the pump and demount the vacuum<br />
relief valve.<br />
- Remove the damper cover (1) and measure<br />
distance A.<br />
- Loosen the locking nut (3) and adjust the<br />
spring tension by turning the spring plate (4).<br />
The compression of the spring (2) determines<br />
the opening pressure. Changing the distance A<br />
by 1.5 mm will give a corresponding change in<br />
pressure of 1 kPa.<br />
- Remount the valve after adjustment and test<br />
the pressure.<br />
9. Inspect all cables and connections, repair<br />
if neccessary.<br />
10. Remount the protective panels, power up<br />
the pump and give it a test run.<br />
2.<br />
4.<br />
1.<br />
3.<br />
TPR 40, 15 kW - 23 Art nr 9045<br />
F<br />