8. Disassemble the vacuum relief valve (D).<br />

Clean and lubricate shaft and bearings.<br />

Check the rubber gasket (E). Change if<br />

cracked or harden (Part No. 4710).<br />

Check the function of the hydraulic<br />

damper (F).<br />

E<br />

D<br />

Adjusting the vacuum relief valve<br />

The valve is pre-adjusted with a negative pressure<br />

(18 kPa). If this is to be adjusted the following<br />

procedure is used:<br />

- Connect a manometer to the suction side and<br />

measure with fully closed inlet.<br />

- Shut down the pump and demount the vacuum<br />

relief valve.<br />

- Remove the damper cover (1) and measure<br />

distance A.<br />

- Loosen the locking nut (3) and adjust the<br />

spring tension by turning the spring plate (4).<br />

The compression of the spring (2) determines<br />

the opening pressure. Changing the distance A<br />

by 1.5 mm will give a corresponding change in<br />

pressure of 1 kPa.<br />

- Remount the valve after adjustment and test<br />

the pressure.<br />

9. Inspect all cables and connections, repair<br />

if neccessary.<br />

10. Remount the protective panels, power up<br />

the pump and give it a test run.<br />

2.<br />

4.<br />

1.<br />

3.<br />

TPR 40, 15 kW - 23 Art nr 9045<br />