EMC Specification for Rolling Stock LB 2000-03-08 Rev. 3 Page 4/7<br />

<br />

4. Interference Limits<br />

4.1. International Standards<br />

The vehicle must comply with all relevant legislation and international standards,<br />

such as EN (ENV), IEC, and UIC.<br />

Additionally, compliancy with relevant prEN standards should be aimed for.<br />

4.2. Danish Standards for 50 Hz Operation<br />

Section in QN<br />

903 Q nr 0779<br />

The vehicle must comply fully with the standard QN 903 Q nr 0779 from the Danish<br />

National Railway Agency (Banestyrelsen), however with the following<br />

modifications:<br />

Frequency and<br />

time duration<br />

Maximum line current harmonics<br />

Per train, consisting<br />

of 2 locomotives or 3<br />

or more trainsets in<br />

multiple operation<br />

Per individual<br />

locomotive, or 2<br />

trainsets in<br />

multiple operation<br />

Per<br />

individual<br />

trainset<br />

D 150 Hz, > 1 s 10 A 5 A 3.5 A<br />

G2 250 Hz, > 1 s 6 A 3 A 2 A<br />

H<br />

350 Hz, > 1 s 4 A 2 A 1.5 A<br />

450 Hz, > 1 s 3 A 1.5 A 1 A<br />

550 Hz, > 1 s 2 A 1 A 0.7 A<br />

650 Hz, > 1 s 2 A 1 A 0.7 A<br />