Øresundsbro Konsortiet Jernbaneafdelingens procedure
Øresundsbro Konsortiet Jernbaneafdelingens procedure
Øresundsbro Konsortiet Jernbaneafdelingens procedure
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
EMC Specification for Rolling Stock LB 2000-03-08 Rev. 3 Page 4/7<br />
<br />
4. Interference Limits<br />
4.1. International Standards<br />
The vehicle must comply with all relevant legislation and international standards,<br />
such as EN (ENV), IEC, and UIC.<br />
Additionally, compliancy with relevant prEN standards should be aimed for.<br />
4.2. Danish Standards for 50 Hz Operation<br />
Section in QN<br />
903 Q nr 0779<br />
The vehicle must comply fully with the standard QN 903 Q nr 0779 from the Danish<br />
National Railway Agency (Banestyrelsen), however with the following<br />
modifications:<br />
Frequency and<br />
time duration<br />
Maximum line current harmonics<br />
Per train, consisting<br />
of 2 locomotives or 3<br />
or more trainsets in<br />
multiple operation<br />
Per individual<br />
locomotive, or 2<br />
trainsets in<br />
multiple operation<br />
Per<br />
individual<br />
trainset<br />
D 150 Hz, > 1 s 10 A 5 A 3.5 A<br />
G2 250 Hz, > 1 s 6 A 3 A 2 A<br />
H<br />
350 Hz, > 1 s 4 A 2 A 1.5 A<br />
450 Hz, > 1 s 3 A 1.5 A 1 A<br />
550 Hz, > 1 s 2 A 1 A 0.7 A<br />
650 Hz, > 1 s 2 A 1 A 0.7 A<br />
<br />
RollingStockEMCRequirementsShort.doc