13.11.2013 Views

SieiDrive - LIFT - gefran.cz

SieiDrive - LIFT - gefran.cz

SieiDrive - LIFT - gefran.cz

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

50<br />

Lift Control System Catalogues<br />

SIEIDrive<br />

Appendice - Appendix - Anhang - Apéndice<br />

Accessori<br />

Accessories • Accessoires • Zubehörteile<br />

• Accesorios<br />

Input Side External Fuses, without three-phase choke<br />

• Fusibili Esterni Lato Ingresso, senza Induttore Trifase<br />

• Fusibles Réseau Externes, sans Inductance Triphasée<br />

• Externe Sicherungen Eingangsseite, ohne dreiphasige<br />

Netzdrossel<br />

• Fusibles Externos del Lado de Alimentación de Red,sin<br />

Inductancia Trifásica<br />

EUROPE<br />

AMERICA<br />

Size Fuse type Code Fuse type Code<br />

1007 - 1015<br />

1022 - 1030<br />

2040<br />

2055<br />

2075<br />

3110 - 3150<br />

4185 to 81600<br />

1055<br />

1075<br />

1110<br />

1150<br />

1185<br />

2040<br />

2055<br />

2075<br />

3110<br />

3150<br />

4185 to 82000<br />

2030<br />

2040<br />

2055<br />

1425<br />

2545<br />

3360<br />

2040<br />

2055<br />

2075<br />

3110<br />

3150<br />

3150<br />

4371<br />

GRD2/10<br />

GRD2/16<br />

GRD2/20<br />

GRD2/25<br />

GRD3/35<br />

Z22GR63<br />

(*)<br />

GRD2/25<br />

GRD3/35<br />

Z22GR63<br />

Z22GR63<br />

(*)<br />

GRD2/20<br />

GRD2/25<br />

GRD3/35<br />

GRD3/50<br />

GRD3/50<br />

(*)<br />

GRD2/16<br />

GRD2/20<br />

GRD2/25<br />

GRD3/35<br />

GRD3/50<br />

Z22GR63<br />

GRD2/16<br />

GRD2/20<br />

GRD2/25<br />

GRD3/50<br />

GRD3/50<br />

Z22GR63<br />

(*)<br />

F4D13<br />

F4D14<br />

F4D15<br />

F4D16<br />

F4D20<br />

F4M17<br />

F4D16<br />

F4D20<br />

F4M17<br />

F4M17<br />

F4D15<br />

F4D16<br />

F4D20<br />

F4D14<br />

F4D15<br />

F4D16<br />

F4D20<br />

F4M17<br />

F4D14<br />

F4D15<br />

F4D16<br />

F4D20<br />

F4M17<br />

A70P10<br />

A70P20<br />

A70P20<br />

A70P25<br />

A70P35<br />

A70P60<br />

(*)<br />

A70P25<br />

A70P35<br />

A70P60<br />

A70P60<br />

(*)<br />

A70P20<br />

A70P25<br />

A70P35<br />

A70P40<br />

A70P40<br />

(*)<br />

A70P20<br />

A70P20<br />

A70P25<br />

A70P35<br />

A70P40<br />

A70P60<br />

A70P20<br />

A70P20<br />

A70P25<br />

A70P35<br />

A70P40<br />

A70P60<br />

(*)<br />

S7G49<br />

S7G48<br />

S7G48<br />

S7G51<br />

S7G86<br />

S7G52<br />

S7G51<br />

S7G86<br />

S7G88<br />

S7G88<br />

S7G48<br />

S7G51<br />

S7G86<br />

S7G48<br />

S7G48<br />

S7G51<br />

S7G86<br />

S7G52<br />

S7G88<br />

S7G48<br />

S7G48<br />

S7G51<br />

S7G86<br />

S7G52<br />

(*):<br />

• For these types an external choke is mandatory if the AC input impedence is equal or less than 1%.<br />

• Per questi modelli l’induttanza esterna è obbligatoria se l’impedenza della rete è uguale o inferiore all’1%.<br />

• Pour ces tailles, une inductance externe est requise si l'impédance du réseau est inférieure ou égale à 1%<br />

• Fuer diese Modelle ist die Netzdrossel notwendig, falls die Netzimpedance gleich bzw. kleiner 1% ist.<br />

• Para estos modelos, la inductancia externa es obligatoria si la impedancia de la red es igual oinferior al 1%.<br />

AVyL AC4 / BR4<br />

l<br />

l<br />

l<br />

l<br />

l<br />

l<br />

AVMs<br />

l<br />

l<br />

l<br />

l<br />

l<br />

AGyL<br />

l<br />

l<br />

l<br />

l<br />

l<br />

QUIX L<br />

l<br />

l<br />

l<br />

AVRy<br />

l<br />

l<br />

l<br />

Lift Drive System<br />

• with AVyL<br />

l<br />

l<br />

l<br />

l<br />

l<br />

l<br />

Lift Drive System<br />

• with AGyL<br />

l<br />

l<br />

l<br />

l<br />

l

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!