on<br />

off<br />

on<br />

off<br />

on<br />

off<br />

inverter<br />

inverter on<br />

overload<br />

low battery<br />

temperature<br />

inverter<br />

inverter on<br />

overload<br />

low battery<br />

temperature<br />

inverter<br />

inverter on<br />

overload<br />

low battery<br />

temperature<br />

The inverter has switched off due to<br />

the electronics temperature being<br />

too high.<br />

-If the LEDs are flashing alternately,<br />

the battery is nearly exhausted and<br />

the nominal output is exceeded.<br />

-If "overload" and "low battery" flash<br />

simultaneously, the ripple voltage on<br />

the battery terminals is too high.<br />

The inverter switched off due to<br />

excess ripple voltage on the battery<br />

terminals.<br />