• Maximum pressure 0.4 bar (5.8 psi.).<br />

• Always keep UV-C units and UV-C lamps out of the<br />

reach of children!<br />

• Ensure that there is sufficient water flow through<br />

the sera fil bioactive + UV external filter before<br />

switching on the UV-C lamp. A minimum flow rate<br />

must be ensured also during operation.<br />

• Too frequent “ON/OFF” switching reduces the life<br />

expectancy of the UV-C lamp.<br />

• Ensure that the electrical plug of the switched-on<br />

unit is freely accessible at all times.<br />

• Damage of the pump head, the cable or the plug<br />

must not be repaired! In this case the filter must<br />

immediately be disconnected from mains supply,<br />

and must not be operated any more. This also applies<br />

in case of intended alterations of these<br />

parts. This kind of damage must not be repaired<br />

or mended. In case of damage or leakage at the filter<br />

canister, at the seals, or in the parts that contain<br />

water, the filter must immediately been taken<br />

apart and repaired.<br />

• The filter must be connected with a fault current<br />

protection switch (RCD 30 mA).<br />

Warning<br />

1. Children should be supervised to ensure that they<br />

do not play with the appliance.<br />

2. This appliance is not intended for use by persons<br />

(including children) with reduced physical, sensory<br />

or mental capacities, or lack of experience and<br />

knowledge, unless they have been given supervision<br />

or instruction concerning use of the appliance<br />

by a person responsible for their safety.<br />

3. If the supply cord is damaged, it must be replaced<br />

by the manufacturer, its service agent or similarly<br />

qualified persons in order to avoid a hazard.<br />

UV-C System<br />

Wattage of the sera UV-C energy saving lamp:<br />

130 + UV: 5 W<br />

250 + UV, 400 + UV: 5 W<br />

F<br />

IPX4<br />

Troubleshooting<br />

Problem Possible cause Possible solution<br />

Filter does not pump water Too much air inside the filter Use pump handle, if necessary<br />

open and fill with aquarium water<br />

by 3/4<br />

No electrical supply<br />

Rotor does not move<br />

Connect to power/mains supply<br />

Take off filter head and clean<br />

Outlet valve is not open Throw multi-purpose handle (3.5)<br />

Pump performance is very low Too much air inside the filter Use pump handle (3.10)<br />

Filter is clogged<br />

Clean filter, if necessary replace<br />

filter media with new ones<br />

For units with UV-C lamp<br />

Control LED is not lit No electrical supply Check plug<br />

Cloudiness/algae remain<br />

unaffected<br />

UV-C lamp is not properly<br />

connected<br />

UV-C lamp faulty<br />

No bacterial cause, mineral<br />

cloudiness<br />

UV-C lamp faulty/too old<br />

Check cable connection<br />

Replace lamp unit<br />

Clean or replace filter mat (floss)<br />

and sponge, water change<br />

Replace lamp unit<br />

Recommendations<br />

• Additionally secure all hose connections with<br />

stainless steel hose clamps.<br />

• Always carry the filter by supporting the bottom.<br />

Never lift it by the filter head, its external parts or<br />

its hose connections.<br />

• Replace all hoses and the filter head seal every<br />

2 years. Grease the filter head seal with Vaseline<br />

every time before you close the filter.<br />

• Place the filter into a plastic bowl. Direct a hose<br />

and cable loop into the bowl to avoid damage<br />

caused by dripping water.<br />

18