Pos: 136 /Alle Produkte/Überschriften/H1 Störungsbeseitigung @ 7\mod_1196625290699_121.doc @ 41521 @ @ 1<br />

9. Remedy of faults<br />

Pos: 137 /Filter/<strong>FiltoMatic</strong> <strong>CWS</strong>/Störungstabelle_<strong>FiltoMatic</strong>_<strong>CWS</strong> @ 14\mod_1259929430129_121.doc @ 85203 @ @ 1<br />

Malfunction Cause Remedy<br />

The controller does not switch on<br />

No mains voltage Check mains voltage<br />

Check supply lines<br />

Controller incorrectly positioned on the UVC<br />

clarifying unit<br />

Check the controller seating<br />

Water from the DN70 outlet does not return Aquamax pump not switched on Switch on Aquamax pump<br />

to the pond Stop valve closed with the lid open Open stop valve<br />

Dirty water pump does not switch on Pump rotor blocked Clean pump rotor<br />

Container already empty Fill container<br />

Container partly emptied, dirty water pump<br />

cannot prime<br />

Fill container<br />

UVC lamp does not switch on<br />

Pos: 138 /Alle Produkte/Dummy_module/===== Seitenwechsel ===== @ 0\mod_1125648978015_0.doc @ 1631 @ @ 1<br />

The cleaning programs are inactive at water<br />

temperatures between35 °C<br />

The dirty water pump has reached its max.<br />

running time. The display shows "PS".<br />

- GB -<br />

Now the dirty water pump can only be<br />

operated manually.<br />

− Keep the PUMP key pressed for complete<br />

drainage.<br />

Wait for 1.5 hours. Once this time has<br />

elapsed, the dirty water pump is operational<br />

again.<br />

UVC lamp defective Changing the UVC lamp<br />

The safety system in the UVC clarifying unit<br />

has tripped as a result of overvoltage in the<br />

mains<br />

Switch of the mains voltage and on again to<br />

reset the safety system<br />

− Check that the UVC lamp is lit in the<br />

control window (blue light)<br />

− To test, we suggest to switch on the UVC<br />

lamp using the UVC key (operating status<br />

ON)<br />

31