SYNERGY IN FIRECUT EI2 90<br />

SCHEMA TECNICO UN BATTENTE<br />

TECHNICAL DIAGRAM SINGLE LEAF<br />

ESPLICATIVO PER PORTE SYNERGY IN FIRECUT EI290<br />

BATTENTE SINGOLO -(carenatura agraffa)<br />

SEZIONE ORIZZONTALE<br />

YOUR HOME, YOUR LIFE<br />

LATO INTERNO<br />

INTERNAL SIDE<br />

Silbifire da 3 mm<br />

Silbifire 3mm<br />

Pannello int. da 4 mm<br />

4 mm internal panel<br />

Guarniz. bifireseal<br />

Bifireseal seal<br />

8,5<br />

49<br />

63<br />

Pannello est. da 4 mm<br />

4 mm external panel<br />

25<br />

3<br />

60<br />

Guarniz. termoespandente<br />

Heat-expanding seal<br />

LNL= luce netta larghezza (o larghezza passaggio)<br />

LNL= net opening width (or passage width)<br />

MASSIMO INGOMBRO CONTROTELAIO<br />

COUNTERFRAME MAXIMUM DIMENSION<br />

19 38<br />

60<br />

3<br />

LATO ESTERNO<br />

EXTERNAL SIDE<br />

SEZIONE VERTICALE<br />

3<br />

Particolare X<br />

Item X